The document provides detailed specifications for the ICO4S 2/2, 3/2, or 5/2 poppet valve, which is an electromagnetically actuated valve designed for controlling hydraulic or pneumatic equipment. Key features include a port size range of 1/4” to 3/4”, high flow capabilities, and a maximum inlet pressure of 414 bar, along with various certifications for safety and environmental protection. It also includes information on operating pressures, temperature ranges, and material specifications, emphasizing the importance of proper usage in industrial compressed air systems.

Uploaded by

Adnan gerom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
20 views12 pages

IMI-Thompson-Valves_ICO4S_Data-Sheet_23Oct24-1

The document provides detailed specifications for the ICO4S 2/2, 3/2, or 5/2 poppet valve, which is an electromagnetically actuated valve designed for controlling hydraulic or pneumatic equipment. Key features include a port size range of 1/4” to 3/4”, high flow capabilities, and a maximum inlet pressure of 414 bar, along with various certifications for safety and environmental protection. It also includes information on operating pressures, temperature ranges, and material specifications, emphasizing the importance of proper usage in industrial compressed air systems.

Uploaded by

Adnan gerom
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 12

Process

Automation
Our product brands:
IMI MAXSEAL®

ICO4S 2/2, 3/2 or 5/2


Poppet Valve
Electromagnetically Actuated,
Directly Controlled

Breakthrough
engineering for
a better world
ICO4S 2/2, 3/2 or 5/2
Poppet Valve

Key Benefits

- Port size: 1/4” ... 3/4” (ISO G/NPT) or


manifold version
- Direct acting solenoid valve for the control
of hydraulic or pneumatic equipment
- High flow
- Up to 414 bar inlet pressure
- Reliable and long life, ideal for a one time
installation
- Certifications: ATEX, CSA, NEPSI, KOSHA,
IECEx, FM, CRN, CCOE, IN-METRO
- Environmental protection:
NEMA 4X, IP66/X8

Technical Features

Medium Hydraulic and pneumatic – customer to specify and confirm compatibility

Operation Direct solenoid operated poppet valves

Mounting Position Solenoid vertical

Flow 0,8 Cv ... 5.0 Cv

Port Size 1/4”, 1/2” & 3/4” NPT, ISO G and manifold

0 ... 20 bar (0 ... 290 psi)


Operating Pressure
0 ... 50 bar (0 ... 725 psi)

0 ... 207 bar (0 ... 3002 psi)

0 ... 414 bar (0 ... 6004 psi)

Media: -20 ... +90°C (-4 ... +194°F)


Options to -60°C (-76°F) available on request.
Temperature Ambient: See table on page 2

Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F)

Valve body, trim, coil housing and top cover: stainless steel 1.4404 (316 L)
Materials O-rings seats & seals: high NBR
Other seal materials available on request

These products are intended for use in industrial compressed air systems Through misuse, age, or malfunction, components used in fluid power systems can fail in
only. Do not use these products where pressures and temperatures can various modes. The system designer is warned to consider the failure modes of all component
exceed those listed under »Technical features/data«. Before using these parts used in fluid power systems and to provide adequate safeguards to prevent personal
products with fluids other than those specified, for non-industrial injury or damage to equipment in the event of such failure. System designers must provide a
applications, lifesupport systems or other applications not within warning to end users in the system instructional manual if protection against a failure mode
published specifications, consult Thompson Valves Ltd. cannot be adequately provided. System designers and end users are cautioned to review
specific warnings found in instruction sheets packed and shipped with these products.
Technical Data – Standard Models
with Conduit Connection M20 X 1,5

Symbol Port Function Operating Material Manual ATEX Power Ambient Temperature Weight Drawing Model
Size Pressure Seat Seal Override/ Certification Consumption (kg) No.
(bar) Reset 24 V d.c. (W)

1/4 NPT 2/2 NC 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5 1 Y121AA1H1*S
G 1/4 2/2 NC 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5 1 Y121AE1H1*S
1/2 NPT 2/2 NC 0 ... 50 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 2 Y131AA3H1*S
2
G 1/2 2/2 NC 0 ... 50 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 2 Y131AE3H1*S
V-22C-E-F
1/2 NPT 2/2 NC 30 ... 414 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 3 Y191AA3J1*S
1
G 1/2 2/2 NC 30 ... 414 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 3 Y191AE3J1*S
2
3/4 NPT 2/2 NC 0 ... 12 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 4 Y113AA5H1*S
V-22C-EH-F
G 3/4 2/2 NC 0 ... 12 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 4 Y113AE5H1*S
1
Manifold 2/2 NC 0 ... 207 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 6 5 Y161AKFJ1*S
2 Manifold 2/2 NC 0 ... 414 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 6 5 Y191AKFJ1*S
V-22C-ER-F
11 2

1/4 NPT 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 6 Y121PA1H1*S
2
G 1/4 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 6 Y121PE1H1*S
1/2 NPT 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 7 Y121PA3H1*S
1
G 1/2 2/2 NC 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 7 Y121PE3H1*S
1/4 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 8 Y123AA1H1*S
G 1/4 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 8 Y123AE1H1*S
2
1/2 NPT 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 9 Y123AA3H1*S
V-32C-E-F
G 1/2 3/2 UNI 0 ... 20 NBR Without Exd IIC T6 9,6 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 9 Y123AE3H1*S
1 3
3/4 NPT 3/2 UNI 0 ... 12 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 10 Y113AA5H1*S
2
G 3/4 3/2 UNI 0 ... 12 NBR Without Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 10 10 Y113AE5H1*S
V-32C-EH-F
1/4 NPT 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 11 Y123PA1H1*S
12 3
G 1/4 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 11 Y123PE1H1*S
2 1/2 NPT 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 6,0 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 12 Y123PA3H1*S
1 3
V-32C-ER-F
G 1/2 3/2 UNI 0 ... 20 NBR PBMR* Exd IIC T6 6,0 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 12 Y123PE3H1*S
1 3
1/4 NPT 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 13 Y123BA1H1*S
2
G 1/4 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 13 Y123BE1H1*S
1/2 NPT 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 14 Y123BA3H1*S
1 3
G 1/2 3/2 UNI 0 ... 20 NBR A-L-L* Exd IIC T6 15,1 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 14 Y123BE3H1*S
2 1/4 NPT 3/2 UNI 0 ... 20 NBR JSMO* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 15 Y123SA1H1*S
G 1/4 3/2 UNI 0 ... 20 NBR JSMO* Exd IIC T6 4,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 5,5 15 Y123SE1H1*S
1 3

4 2 1/2 NPT 5/2 UNI 0 ... 12 NBR Without Exd IIC T6 7,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 16 Y115AA3H1*S
G 1/2 5/2 UNI 0 ... 12 NBR Without Exd IIC T6 7,5 T6 (-60 … +48°C), T4 (-60 ... +90°C ) 7,5 16 Y115AE3H1*S
51 3

4 2
* Insert voltage code - V-52-EH-F
see option selector on page 3
Other product
5 1 3 and body material available for more information contact IMI technical service
PBMR = Push button manual reset, A-L-L = Automatic latching lever, JSMO = Jack screw manual override
Option Selector

Y1 S

Operating Pressure Substitute Voltage Substitute

0 ... 12 bar (0 ...175 psi) 1 18 /33 V d.c. A

0 ... 20 bar (0 ... 290 psi) 2 24 V d.c. B

0 ... 50 bar (0 ... 725 psi) 3 48 /50 V d.c. (50 V) C

0 ... 207 bar (0 ... 3002 psi) 6 110 V d.c. D

0 ... 414 bar 9 125 V d.c. E

Port Configuration Substitute 220 /240 V d.c. (240 V) F

2/2 NC 1 24 V a.c. G

2/2 NO 2 110 V a.c. J

3/2 (universal) 3 12 V d.c. L

5/2 (universal) 5 220 /240 V a.c. (240 V) M

Operation Substitute Conduit Connection Substitute

Automatic A M20 x 1.5 mm 1

Automatic latching lever B 1/2 NPT 2

Push button manual override C Seat/Seal Material Substitute

Lever manual reset (414 bar only) L High Nitrile (standard) H

Lever manual override (414 bar only) M FKM V

Push button manual reset P

Jack screw manual override S

Tamper proof manual reset T

Port Size Substitute

1/4 NPT A1

G 1/4 E1

1/2 NPT A3

G 1/2 E3

3/4 NPT A5

G 3/4 E5

Manifold KF
Dimensions Dimensions in mm
Projection/First angle

1 A
58,5 ø 82

1
View A

36,5
55 22
2
20

21

M8
38,5
30
180
1

57
2

32,5
21,5
51 ø 56

2
A
58,5 ø 82

1
36,5

2 View A
20
21

55 22
38,5

M8
30
227

1
104

2
60
58

70
ø 76

55 22
M8

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
Dimensions in mm
Projection/First angle

3 A
58,5 ø 82

36,5
2 View A
20

21
55 22

38,5

M8
30
303
2
127

1
85
62

ø 35 ø76
68

A
58,5 ø 82
4
1
36,5

2 View A
20
21

55 22
38,5

M8
30
235

2
60
105
57

1
26

30,5 39
70 74

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
Dimensions in mm
Projection/First angle

5 A
58,5 ø 82

36,5
2 View A
20

21
55 22

38,5

M8
30
192
3

6,8
1

63
11

2 37
27
17

51 38
51

A
58,5 ø 82
6
1
36,5

2 View A
20
21

55 22
38,5

M8
30
200

1
2
77

6
53
42
14

51 ø 57

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
3 ø 5 mm drilled ports supplied with O-rings
6 Push button manual reset
Dimensions in mm
Projection/First angle

7 A
58,5 ø 82

36,5
2 View A
20

21
55 22

38,5

M8
30

247,5
1

124,5
2
80,5
78,5

6
14

70 ø 76

8 A
58,5 ø 82

1
36,5

2 View A
20
21

55 22
38,5

M8
30
190

1
2
68
43,5

3
32,5
21,5

51 ø 56

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
6 Push button manual reset
Dimensions in mm
Projection/First angle

9 A
58,5 ø 82

36,5
2 View A
20

21
55 22

38,5

M8
30
243
1

120
2
80
3
58
36

70 ø 76

10 A
58,5 ø 82

1
36,5

2 View A
20
21

55 22
38,5

M8
30
235

3
105

2
85

1
57
26

39 30
74 70

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
Dimensions in mm
Projection/First angle

11 A
58,5 ø 82

36,5
2 View A
20

21
55 22

38,5

M8
30
211
1
2

89
3

64,5
6
53
14

51 ø 57

12
A
58,5 ø 82

1
36,5

2 View A
20
21

55 22
38,5

M8
30

265

1
142

3
102
80
58

6
14

70 ø76

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
6 Push button manual reset
Dimensions in mm
Projection/First angle

13 A
58,5 ø 82

36,5
2 View A
20

21
55 22

38,5

M8
30
186
1

63
2

39
3
28
17

51 56

14
A
58,5 ø 82

1
36,5

2 View A
20
21

55 22
38,5

M8
30
243

1
120

2
80

3
58
36

76

70

1 Conduit connection M20 x 1,5 or 1/2 NPT


2 External earth
7 Automatic latching lever
Dimensions in mm
Projection/First angle

15 A
Dimensions in mm
58,5 ø 82 Projection/First1angle
2
15 1 A 3

36,5
58,5
2
ø 82
View A
20

21
1 55 22

38,5
51

36,5
2 View A

M8
38,5 30
20

21
55 22

211

M8
30
1 16 58,5

211
2

89
3

64,5
5

53
42
1
2

89
3 ø 57 20
51

64,5
5

53
42
51 ø 57

A
16 58,5 ø 82

3
1 A
36,5

16 58,5 ø 82
2
2 View A
20 1
21

1
55 22
38,5
36,5

4
2 View A

M8
38,5 30

41
20
21

55 22
5
264

44

M8
30

63,5
3
264

2
48
??

13
48

2
48
48

4
1 Conduit connection M20 x 1,5 or 1/2 NPT
??
41

15
48

2 External earth
48 17

5 Jack screw manual override


44 4 28,5
63,5
41

5
17

44 28,5
63,5

Process
1
2
Conduit connection M20 x 1,5 or 1/2 NPT
External earth

Automation
5 Jack screw manual override

1 Conduit connection M20 x 1,5 or 1/2 NPT IMI Thompson Valves


2 External earth
The information in this brochure is provided for
5 Jack screw manual override 17 Balena Close,
general informational purposes only. Specifications for
products and services are subject to change without
Creekmoor, Poole
prior notice. IMI plc and its subsidiaries own all product BH17 7EF
brands mentioned herein. United Kingdom
IMI makes no warranties or representations about
the accuracy or completeness of the content in
this brochure and assumes no liability for any errors [email protected]
or omissions it may contain. We reserve the right
to modify, enhance, or discontinue any product or www.imiplc.com
service described herein without prior notification. 14003.02/24en

You might also like