0% found this document useful (0 votes)
16 views1 page

g1 Swastik Dev First FL Beam SCH

The document outlines specifications for various beams, including dimensions, bar sizes, and stirrup details for a construction project. It includes information on support types, additional stirrups, and specific remarks for each beam. The project is associated with Swastik Developers and involves complex construction at Kopergaon, as detailed by SAI Consultants.

Uploaded by

kpn.archdesign
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views1 page

g1 Swastik Dev First FL Beam SCH

The document outlines specifications for various beams, including dimensions, bar sizes, and stirrup details for a construction project. It includes information on support types, additional stirrups, and specific remarks for each beam. The project is associated with Swastik Developers and involves complex construction at Kopergaon, as detailed by SAI Consultants.

Uploaded by

kpn.archdesign
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BOTTOM BENTUP ADDITIONAL STIRRUPS Ø6MM

SIZE MM AT DIST.
TOP Ø6 SPA- FOR
BARS NEAR STIRRUPS
BEAMS MARKED REMARK

T
BENT/ FROM

H
BARS DI CING A SUP- ELSEWHERE

IG
b D CUT/ FACEOF

A
C / C DIST. PORT AT C / C

R
A

ST
FULL SUPORT
B- 1,2,4,5,7,69,75,76,77,78,79,80,159,160, 150 600 2 # 8 2 # 8 230
B- 3,73,83,84,129,133, 150 600 2 # 10 2 # 8 230 1 # 12 EXTRA OVER C-19
B- 6,8,72,74,114,115,127,145,146, 150 600 3 # 12 2 # 8 Ø6 175 1000 ???? 230 ???? - B - 91,96,143,148,C-21,13,30
B- 9,12,22,28,51,56,67,71,131,134, 150 600 2 # 8 3 # 12 200 CANTILEVER
400
B- 10,11,68,70, REFER DETAILS 150 2 # 20 2 # 10 # 8 @ 300
600
B- 13,65, 530 750 6 # 25 6 # 25 FULL 6 # 25 FOUR LEGGED STIRRUPS # 8 @ 200
B- 15,16,17,62,63,64, 230 110 3 # 12 2 # 8 150 HIDDEN BEAM
B-18,19,20,21,30,42,57,58,59,61,105,106,128, 100/150 300 2 # 8 2 # 8 200
B- 23,27,52,55, 150 600 2 # 16 2 # 12 # 8 @ 300
B- 24,26,53,54, CANTILEVER 150 600 2 # 8 2 # 12 # 8 @ 230 2 # 16 EXTRA OVER C-12,15,29,33
2 # 16
B- 25, 230 600 3 # 20 2 # 20 FULL #8 230 1800 BOTH # 8 @ 400
1 # 12
B- 29,32,44,46,49, 150 300 2 # 12 2 # 8 200
400
B- 37,48,99,100, REFER DETAILS 150 2 # 16 2# 8 Ø6 175 700 BOTH 230 1 # 12 EXTRA OVER C-18,27,B-39A
600
B- 30A,42A, 230 100 2 # 10 2 # 8 150 HIDDEN BEAM
B- 31,36,43,47,60,118,119,139,140, 150 300 3 # 12 2 # 8 Ø6 150 600 BOTH 200 1 # 12 EXTRA OVER C-26
B- 33, 150 600 2 # 20 2 # 16 FULL 3 # 12 #8 300 1500 BOTH 230
B- 35, 150 600 2 # 12 2 # 12 230 TIE
B- 38,41, 230 600 2 # 8 2 # 12 150 CANTILEVER
B- 39,39ACANTILEVER, 150 600 2 # 16 2 # 20 # 8 @ 150 2 # 16 EXTRA OVER C-20
B- 40,97,98,141,142, 150 380 2 # 16 2 # 8 230
B- 45, 150 600 2 # 16 2 # 16 FULL 2 # 12 #8 300 1500 BOTH 230
B- 50, 230 600 4 # 20 3 # 12 #8 300 1500 BOTH # 8 @ 400
B- 81,86,153,158, 600 600 7 # 20 7 # 20 FOUR LEGGED STIRRUPS # 10 @ 90 CANTILEVER
B- 82,85,92,95,144,147, 600 600 2 # 20 2 # 20 # 8 @ 175
B- 87,90,112,117,149,152, 150 600 2 # 8 2 # 8 150 CANTILEVER 1#12 EXTRA OVER C-5,39
B- 88,89,113,116,121,122,150,151, 150 300 2 # 16 2 # 8 200
B- 91,96,143,148, CANTILEVER 600 750 4 # 12 6 # 20 FOUR LEGGED STIRRUPS # 10 @ 90 6 # 20 EXTRA OVER C-2,9,36,43
B- 93,94, 230 300 2 # 16 1 # 12 CUT 2.0 2 # 8 175 1 # 16 EXTRA OVER C-20
B- 101,104,135,138, 150 600 2 # 8 2 # 20 # 8 @ 230 CANTILEVER
1 # 12 CUT2.5
B- 102,103,108,110,136,137, 150 600 2 # 12 2# 8 #8 230 1200 BOTH 230
1 # 12 CUT3.5
B- 107,111, CANTILEVER 150 600 2 # 8 2 # 16 # 8 @ 230 1 # 12 EXTRA OVER C-4,38
B- 120,123,126,130, 150 600 2 # 8 2 # 12 200 CANTILEVER
300
B- 124,125, REFER DETAILS 150 3 # 12 2# 8 200
500
B- 132, 150 600 2 # 20 2# 8 #8 300 1300 C-41 230
B- 154,157, 600 900 6 # 25 6 # 25 FULL 7 # 20 FOUR LEGGED STIRRUPS # 8 @ 150 4 # 12 FACE BARS
COMPLEX AT KOPERGAON FOR SWASTIK DEVELOPERS, ARCH. KUNAL NAVLE,
SAI CONSULTANTS JOB NO. G1 / 35011 / 01 // 2023 - 24 FIRST FLOOR LEVEL