Atys P - Automatic Transfer Switching Equipment - Catalogue - Pages - 2025 03 - PCG129 - en - 1
Atys P - Automatic Transfer Switching Equipment - Catalogue - Pages - 2025 03 - PCG129 - en - 1
Strong points
atys-p_001.psd
Advantages
B U R E A U
Recording of events Power measurements VERITAS
ATyS p switches enable effective monitoring of ATyS p products are particularly suited to (1) Product references on request.
your installation thanks to timestamped event energy management and monitoring.
recording. In addition to their integrated power and Webserver
Events can be retrieved and read via energy measurement functions (with a 2%
communication. accuracy level), programmable inputs/outputs The Webserver function
can be utilised to control load shedding based comprises HTML pages
Optional communication modules on a load level or tariff. embedded in the Ethernet
The ATyS p offers communication functions communication module.
through the addition of optional modules, Possibility to set periodic genset startup These pages can be accessed
such as RS485 Modbus or Ethernet with ATyS p switches offer additional functions for via an internet browser, simply
embedded Webserver. maintenance. They include a programmable by entering the IP address.
genset starting function which allows the
The webserver offers the
Configuration software starting dates and operating times to be
following functionalities:
configured.
Software (Easyconfig) is available enabling the > Display of source status and
ATyS p parameters to be easily configured switch position
and the existing configuration to be saved and
sent to other units. > Display of the main
measurements
> Extraction of the latest
logged events
> Display of the product
configuration
Front panel
3
1. Slots for optional plug-in modules.
2. Backlit LCD display.
1 3. Source availability and position indication LEDs.
4. Parameter programming keypad.
atys-p_001x_a_1.eps
atys-p_064_a_en.eps
Webserver
Thanks to optional modules, ATyS p can
communicate in Modbus and Ethernet
protocols.
The Ethernet communication module includes
the Webserver function for access to the
ATyS p via an internet browser.
References
ATyS p
Voltage sensing
Rating (A) / and power Optional
(3)
Frame size No. of poles ATyS p Bridging bars supply kit Terminal shrouds Terminal screens modules Auxiliary contact
3P 9573 3012
125 A / B3
4P 9573 4012
3P 3P 3P
3P 9573 3016 1559 3012 2694 3014(2) 1509 3012
160 A / B3 4109 0019
4P 4P 4P
4P 9573 4016
1559 4012 2694 4014(2) 1509 4012
3P 9573 3020
200 A / B3
4P 9573 4020
ATyS p
Key handle
Rating (A) / 3 position interlocking Door protective Remote control
Frame size No. of poles ATyS p DC power supply padlocking system surround interface
3P 9573 3012
125 A / B3
4P 9573 4012
3P 9573 3016
160 A / B3
4P 9573 4016
3P 9573 3020
200 A / B3
4P 9573 4020
3P 9573 3025
250 A / B4
Using lock
4P 9573 4025 RONIS EL11AP
9599 0003(1) 1539 0012
in position 0
3P 9573 3031
315 A / B4
9599 1006(1)
4P 9573 4031
12 VDC/230 VAC
3P 9573 3040 1599 5012
400 A / B4
4P 9573 4040 24 VDC/230 VAC
1599 5112
3P 9573 3050
500 A / B5
48 VDC/230 VAC
4P 9573 4050 D20
1599 5212
9599 2020
3P 9573 3063 +
630 A / B5
RJ45 cable
4P 9573 4063
connection
3P 9573 3080 1599 2009
800 A / B6
4P 9573 4080
3P 9573 3100
1000 A / B6
4P 9573 4100
3P 9573 3120
1250 A / B6
4P 9573 4120
Using lock
3P 9573 3160 RONIS EL11AP
1600 A / B7 9599 0004(1) 1539 0080
in position 0
4P 9573 4160
9599 1004(1)
3P 9573 3200
2000 A / B8
4P 9573 4200
3P 9573 3250
2500 A / B8
4P 9573 4250
3P 9573 3320
3200 A / B8
4P 9573 4320
(1) Factory mounting only.