0% found this document useful (0 votes)
4 views

Sencon 2.0 Software Update Version 2

The document provides a detailed guide for updating the Sencon 2.0 software, emphasizing the need for qualified professionals to follow safety regulations during the process. It outlines the steps for preparing the machine, downloading the update files, and executing the update through the machine's maintenance mode. Additionally, it includes troubleshooting tips for common issues that may arise during the update process.

Uploaded by

Eliyah Ybañez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views

Sencon 2.0 Software Update Version 2

The document provides a detailed guide for updating the Sencon 2.0 software, emphasizing the need for qualified professionals to follow safety regulations during the process. It outlines the steps for preparing the machine, downloading the update files, and executing the update through the machine's maintenance mode. Additionally, it includes troubleshooting tips for common issues that may arise during the update process.

Uploaded by

Eliyah Ybañez
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Sencon 2.

Software Update Process


Disclaimer
These instructions are an aid for the professional and not meant for laymen. These instructions describe the installation or
modification of a standard machine. In some cases, by non-standard machines one may need to deviate from these instructions.
The correct execution calls for qualified professional personnel. The person/company performing the modification/repair is
responsible for training. All valid safety regulations and the regulatory requirements must be observed during maintenance and
repair work to prevent injury to persons, damage to the product or to the environment. The person performing the job must
familiarize themselves with these regulations before beginning. The respective operating instructions and possible machine
operator regulations must also be observed. While SENNEBOGEN LLC has made every effort to ensure this guide is accurate,
SENNEBOGEN LLC will not be liable for any mistakes, errors, or omissions arising as a result of information contained in this
guide. If no torque values have been specified, the DIN 13 applies.

Preparing the Machine


1. Place the attachment on the ground.
2. Park the machine on a level surface and secure the machine so that it cannot roll away by inserting wheel chocks at the
wheels of the rigid axle.
3. Turn the engine off and secure against unintentional restart.
4. Switch the battery isolator to the "off" position.
Follow the process below that outlines how to update your
Sencon 2.0 with the help of Sennebogen Technical Support

Sennebogen Technical
Support will send an
email from "We
Transfer."

Click either link pictured


to download a .ZIP file
containing the updated
parameters.
When your file finishes downloading,
click Open file.
Insert a clean USB/Flash Drive, select this drive to
extract your files.

Confirm the files match what you and Sennebogen


Technical Support discussed. Click "Extract all"

Your files will begin to download to your USB/Flash drive.


Your files will appear in a new
window, confirm everything was
extracted to your USB drive.

Remove the USB and proceed to


the Sencon
Press and hold the top right Continue to hold these When you arrive on the blue
two buttons while powering buttons down past the Linux maintenance screen, wait for
on the machine to start up in Penguin logo the loading bar to show
maintenance mode progress.

Continue to hold these Then you may release the


buttons down two buttons
Once the screen has finished
loading, you will be able to select
Press the three circling arrows to select the .ZIP file
your software package to upload.

You may be prompted to cycle the ignition power


during the loading process

The controller will go through the penguin


and blue screen again

After loading, cycle the ignition as prompted

Press the dial button and move


until your .ZIP file is highlighted Use the button under the information icon to
verify the machine serial number and data
Press the single circling
arrow to return to the Use the dial to move to page 6/6 titled
previous screen Request Access and scroll to highlight
and select Requested Level

Press the dial button and use


dial to select the American
flag

Then use the three circling


arrows to select American
English
Highlight "product configurator" and
select with the dial button

Highlight "request code" and use the


dial button to generate a pin

Email a picture of the pin to the


Sennebogen Technical Support rep that
is assisting you

Select enter password to bring up touch


screen entry
The code is not case sensitive.
A flashing square LED indicates you currently
Avoid pressing the capital "C" as that is used to have access
clear the current entry
Use the dial to select screen 5/6 title USB
If options are greyed out instead of black,
remove USB and reinsert Select the correct parameter file, this is typically
titled "Update.xpar" with a capital "U"

Once updated, cycle the ignition and battery power

If you cannot highlight, "parameter update,"


Press the information icon to verify the serial number and
cycle the ignition power and try again
machine information

If the issue persists, cycle the ignition and


If incorrect, cycle the ignition and battery power and recheck
battery power