The document provides a detailed guide for updating the Sencon 2.0 software, emphasizing the need for qualified professionals to follow safety regulations during the process. It outlines the steps for preparing the machine, downloading the update files, and executing the update through the machine's maintenance mode. Additionally, it includes troubleshooting tips for common issues that may arise during the update process.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
4 views
Sencon 2.0 Software Update Version 2
The document provides a detailed guide for updating the Sencon 2.0 software, emphasizing the need for qualified professionals to follow safety regulations during the process. It outlines the steps for preparing the machine, downloading the update files, and executing the update through the machine's maintenance mode. Additionally, it includes troubleshooting tips for common issues that may arise during the update process.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11
Sencon 2.
Software Update Process
Disclaimer These instructions are an aid for the professional and not meant for laymen. These instructions describe the installation or modification of a standard machine. In some cases, by non-standard machines one may need to deviate from these instructions. The correct execution calls for qualified professional personnel. The person/company performing the modification/repair is responsible for training. All valid safety regulations and the regulatory requirements must be observed during maintenance and repair work to prevent injury to persons, damage to the product or to the environment. The person performing the job must familiarize themselves with these regulations before beginning. The respective operating instructions and possible machine operator regulations must also be observed. While SENNEBOGEN LLC has made every effort to ensure this guide is accurate, SENNEBOGEN LLC will not be liable for any mistakes, errors, or omissions arising as a result of information contained in this guide. If no torque values have been specified, the DIN 13 applies.
Preparing the Machine
1. Place the attachment on the ground. 2. Park the machine on a level surface and secure the machine so that it cannot roll away by inserting wheel chocks at the wheels of the rigid axle. 3. Turn the engine off and secure against unintentional restart. 4. Switch the battery isolator to the "off" position. Follow the process below that outlines how to update your Sencon 2.0 with the help of Sennebogen Technical Support
Sennebogen Technical Support will send an email from "We Transfer."
Click either link pictured
to download a .ZIP file containing the updated parameters. When your file finishes downloading, click Open file. Insert a clean USB/Flash Drive, select this drive to extract your files.
Confirm the files match what you and Sennebogen
Technical Support discussed. Click "Extract all"
Your files will begin to download to your USB/Flash drive.
Your files will appear in a new window, confirm everything was extracted to your USB drive.
Remove the USB and proceed to
the Sencon Press and hold the top right Continue to hold these When you arrive on the blue two buttons while powering buttons down past the Linux maintenance screen, wait for on the machine to start up in Penguin logo the loading bar to show maintenance mode progress.
Continue to hold these Then you may release the
buttons down two buttons Once the screen has finished loading, you will be able to select Press the three circling arrows to select the .ZIP file your software package to upload.
You may be prompted to cycle the ignition power
during the loading process
The controller will go through the penguin
and blue screen again
After loading, cycle the ignition as prompted
Press the dial button and move
until your .ZIP file is highlighted Use the button under the information icon to verify the machine serial number and data Press the single circling arrow to return to the Use the dial to move to page 6/6 titled previous screen Request Access and scroll to highlight and select Requested Level
Press the dial button and use
dial to select the American flag
Then use the three circling
arrows to select American English Highlight "product configurator" and select with the dial button
Highlight "request code" and use the
dial button to generate a pin
Email a picture of the pin to the
Sennebogen Technical Support rep that is assisting you
Select enter password to bring up touch
screen entry The code is not case sensitive. A flashing square LED indicates you currently Avoid pressing the capital "C" as that is used to have access clear the current entry Use the dial to select screen 5/6 title USB If options are greyed out instead of black, remove USB and reinsert Select the correct parameter file, this is typically titled "Update.xpar" with a capital "U"
Once updated, cycle the ignition and battery power
If you cannot highlight, "parameter update,"
Press the information icon to verify the serial number and cycle the ignition power and try again machine information
If the issue persists, cycle the ignition and
If incorrect, cycle the ignition and battery power and recheck battery power