ir6800c
ir6800c
Location:
Vertical Size Detection Kit Installation
Subject:
Remedy Against the Glare of Scanning Lamp
Background
Reports of users complaining about the glare of the scanning lamp have been filed, and a vertical size sensor kit (AB/
Inch) will be offered as a remedial kit.
AB-Configuration
Inch-Configuration
(1/10)
Installation Procedure
When installing the Vertical Size Sensor Kit (Inch; FM2-0647), be sure to upgrade the reader controller software
to version 9.02 or later (iR C6800 Series).
[1] [2]
F-1
(2/10)
Be sure to go through the following in strict sequence before starting the work:
1. Turn off the control panel power switch [1].
2. Turn off the main power switch [2].
3. Disconnect the power cable [3] from the power outlet.
[2]
OFF
[1] OFF
ON/OFF
[3]
F-2
1) Remove the 2 screws, and detach the right glass retainer [2]; then, detach the copyboard glass [3].
[1]
[1]
[3]
[3]
[2]
[2]
F-3
(3/10)
[2]
[1]
F-4
3) Remove the 9 screws [1], and detach the CCD unit cover [2].
[1]
F-5
[1]
[1]
[2]
F-6
(4/10)
[1]
[1]
F-7
5) Lift the original size detection unit [1] slightly;then, disconnect the connector [2].
[1]
[2]
F-8
(5/10)
Note:
Pay attention to the location of mounting, as it differs between AB-configuration and Inch- configuration.
- AB-Configuration
[1]
[2]
F-9
- Inch-Configuration
[1]
[2]
F-10
(6/10)
[2]
[1]
F-11
- Inch-Configuration
[2]
[1]
F-12
8) Secure the original size detection unit [1] in place using 3 screw [2].
[1]
[1]
F-13
(7/10)
[2] [1]
F-14
10) Fit the included clamp [1] into the hole [2].
There are multiple holes. Be sure to use the correct hole. (Do not use the hole identified as [3].)
[3]
[1]
[2]
[1]
[2]
[3]
F-15
(8/10)
[1]
F-16
12) Fix the harness [1] in place using 5 clamps [2] and the edge saddle [3].
[3]
[2]
[1]
F-17
(9/10)
[1]
[2] [3]
F-18
14) Mount the CCD unit cover, copyboard glass, right glass retainer, and reader right coverby following the steps
used to detach them but in reverse.
15) Connect the power cable to the power outlet, and turn on the main power switch.
16) Set '1' to the following service mode item: COPIER>OPTION>BODY>SZDT-SW (Category2); then, turn off
and then on the main power.
17) Check to make sure that the size of originals is correctly identified without the scanning lamp going on.
(10/10)