Vicon Tracker User Guide
Vicon Tracker User Guide
VICON TRACKER
USER GUIDE
WHAT'S INSIDE
Vicon Tracker User Guide For use with Tracker 3.10 Page 2 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 3 of 205
21 March 2023, Revision 1
BEYOND MOTION
Document Description
What's new in Describes the latest release of Tracker, including details of
Vicon Tracker how to use the new features.
PDF available from the Vicon documentation website1 and as
online help.
Vicon Tracker User Guide Explains how to use Tracker with Vicon camera systems.
PDF installed with Tracker and available as online help.
Installing and licensing Step-by-step instructions for installing and licensing Tracker.
Vicon Tracker PDF available from the Vicon documentation website and as
online help.
Vicon Tracker Python API Introductory information to help you to start using the Vicon
Quick Start Guide Tracker Application Programming Interface (API).
The User Guide PDF is installed as part of your Tracker software installation.
1 https://docs.vicon.com
Vicon Tracker User Guide For use with Tracker 3.10 Page 4 of 205
21 March 2023, Revision 1
BEYOND MOTION
Regulatory information
For Vicon Tracker regulatory details, see Vicon Tracker regulatory information in
the Tracker documentation area of the Vicon website2.
2 https://docs.vicon.com
Vicon Tracker User Guide For use with Tracker 3.10 Page 5 of 205
21 March 2023, Revision 1
BEYOND MOTION
To get started with Vicon Tracker, you set up your Vicon system and then
prepare the objects for motion tracking.
The user interface guides you through the various tasks. When you are familiar
with the basics, you can customize Tracker to look and behave as you want.
Vicon Tracker User Guide For use with Tracker 3.10 Page 6 of 205
21 March 2023, Revision 1
BEYOND MOTION
The version number is displayed in the bottom left of the window that is
displayed. This information may be requested if you contact Vicon Support with
questions about Vicon Tracker.
Vicon Tracker User Guide For use with Tracker 3.10 Page 7 of 205
21 March 2023, Revision 1
BEYOND MOTION
For further information on how to set up a Vicon system, see Vicon system
configuration and connection examples3 on the Vicon documentation website.
3 https://docs.vicon.com/display/Connect/Vicon+system+configuration+and+connection+examples
Vicon Tracker User Guide For use with Tracker 3.10 Page 8 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
Except where noted, references to Vicon Lock, Lock units, and Lock
apply to all current models of the Vicon Lock unit (at the time of
publication, this includes Vicon Lock Studio and Vicon Lock Lab).
Component Description
Vicon Valkyrie VK26 and VK16 variants of the Valkyrie camera can be used with
cameras Tracker 3.10.
You can use Valkyrie cameras with Vero, Vantage, Viper (including
ViperX) and Bonita cameras in systems running Tracker 3.10 and later.
Caution: If you add Valkyrie cameras to a system that includes T-Series
cameras, the T-Series cameras will not work.
Vicon Viper and Viper cameras and ViperX cameras can be used with Tracker.
ViperX cameras You can use Viper and ViperX cameras in systems running Tracker 3.8
and later.
You can use Viper and ViperX cameras with Valkyrie cameras in
systems running Tracker 3.10 and later.
Vicon Vero Vicon Vero cameras (v1.3 and v2.2) can be used with Tracker.
cameras You can use Vicon Vero cameras in systems consisting of Vantage
cameras and, with Tracker 3.10 and later, in systems of Valkyrie
cameras.
Vicon Vantage Vantage cameras (V16, V8, and V5) can be used with Tracker.
cameras With Tracker 3.10 and later, you can integrate existing systems
consisting of Vantage and Vero cameras into a Valkyrie system.
See also What's New in Vicon Tracker, Vicon Vantage Quick Start
Guide and the Vicon Vantage Reference.
Caution: The use of mixed systems that include Vicon MX T-Series or
older Vicon cameras is not tested or supported and is at your own risk.
Vicon Bonita Vicon Bonita cameras can be used with Tracker.
cameras
Vicon Tracker User Guide For use with Tracker 3.10 Page 9 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Vicon Vicon Lock (Lab and Studio): Facilitates the integration of synchronous
Connectivity third-party equipment with Vicon Vantage and Vicon Valkyrie cameras
units by providing or receiving synchronization and/or timecode. Lock Lab
also provides connectivity for third-party analog capture sources, such
as force plates and EMG equipment. Connects to an Ethernet switch
to which Vicon cameras and the host PC are connected.
Vicon Lock Lab and Vicon Lock Studio hardware units are RoHS-
compliant.
See also About Vicon connectivity units on page 68.
Vicon-supplied Switches obtained from Vicon that may provide PoE+, UPoE, and SFP+
switches connectivity.
Host PC The main PC in the Vicon system, with at least one dedicated Ethernet
port to enable Vicon system communications (in addition to any other
network ports on the PC). Vicon Tracker application software is
installed on this PC. Remote PCs may be used for other Vicon
application software or third-party applications connected to the host
PC via Ethernet.
Vicon cables Proprietary Vicon cables and commercially available cables connect
Vicon system components, providing a combination of power,
Ethernet communication, synchronization signals, video signals, and
data.
Vicon calibration Specialized device used to accurately calibrate the Vicon system.
device
Vicon Supplies for the Vicon system, including markers, tape, and Velcro.
accessories
Vicon Vicon Tracker software, DataStream SDK and Vicon Virtual System.
engineering
software
Additional Depending on your licensing options, your Vicon system may also
analog devices include one or more additional devices, such as LVDTs,
accelerometers, and load cells.
See also Set up analog devices on page 74.
For further details of these components, see the Vicon Vantage Reference Guide
and/or the Vicon Valkyrie Reference Guide (available from the Vicon website4).
4 https://docs.vicon.com
Vicon Tracker User Guide For use with Tracker 3.10 Page 10 of 205
21 March 2023, Revision 1
BEYOND MOTION
Connecting cameras
To connect cameras into your Vicon system, you must specify the correct IP
address for the network card that is connected to the PoE switch.
To watch how to set up Vicon Vero cameras with Vicon Tracker software, see the
Tracker Installation and Training Guide5 on YouTube.
To connect the cameras:
• Open the Control Panel, then click Network and Internet and on the right
side of the panel, under Network and Sharing Center, click View Network
Status and Tasks; or
• Click the Network and Sharing Center icon on the right of the Windows
toolbar and then click Open Network and Sharing Center.
3. Right-click on the network card connected to PoE and then click Properties.
6. In the Properties window, click the Use the Following IP Address radio
button.
9. Click OK.
5 http://youtube.com/watch?v=2QRl2zzwhRk
Vicon Tracker User Guide For use with Tracker 3.10 Page 11 of 205
21 March 2023, Revision 1
BEYOND MOTION
For systems involving only Valkyrie, Vero, Vantage and Bonita cameras, the
shutter period characteristics for all cameras match exactly. Irrespective of
individual cameras' strobe (shutter) settings, the center alignment of these
periods in any Valkyrie/Vantage/Vero/Bonita camera in the same system align
exactly. You do not need to make any adjustments to ensure that this alignment
occurs.
For systems that include Vicon MX T-Series cameras, you may need to make
some manual adjustment. (Note that you cannot use MX T-Series in mixed
systems with Vicon Valkyrie cameras. Although you can use T-Series cameras with
Tracker 3.10, this is not supported or tested. For information on using these
cameras, see Setting up a mixed Vicon camera system in the Tracker User Guide
for versions of Tracker earlier than 3.10.)
You can find diagrams that show examples of mixed systems in Vicon system
configuration and connection examples6.
6 https://docs.vicon.com/display/Connect/Vicon+system+configuration+and+connection+examples
Vicon Tracker User Guide For use with Tracker 3.10 Page 12 of 205
21 March 2023, Revision 1
BEYOND MOTION
You create and edit the following Vicon configuration file types during motion
capture and analysis:
Vicon Tracker User Guide For use with Tracker 3.10 Page 13 of 205
21 March 2023, Revision 1
BEYOND MOTION
• View pane: Enables you to set up the way you want to visualize the capture
data from one or more cameras. See Viewing camera data on page 152.
Vicon Tracker User Guide For use with Tracker 3.10 Page 14 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Communications pane: Enables you to view log information. See About the
Communications pane on page 149.
• Menu bar: Enables you to exit Tracker, undo/redo, open close panels, view
help, software version, and licensing information. See About the menu bar on
page 177.
In the Resources pane and view pane, you use the tabs and buttons to access the
tools and options for a specific workflow.
Vicon Tracker User Guide For use with Tracker 3.10 Page 15 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Click the Dock Pane button on the right side of the pane title bar.
To dock Resources or Communication panes:
• Double-click the pane title bar. The pane is docked in its last fixed position.
2. Drop the pane anywhere in the window to change it into a floating pane.
2. Click and drag the arrow to move the split line left or right to resize the pane
width, or up and down to resize the section height.
Vicon Tracker User Guide For use with Tracker 3.10 Page 16 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Click the Hide Section arrow or the Display Section arrow to the
right of the section heading.
Tip
The view pane cannot be undocked or repositioned in the Tracker window.
You can open a separate floating view pane by selecting the New floating
workspace option from the Window menu. This floating workspace can be
repositioned and resized.
Vicon Tracker User Guide For use with Tracker 3.10 Page 17 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. In the Tracker window, click on the relevant tab or open the dialog box
containing the properties you want to configure:
• For system components, in the Resources pane, click the System tab.
• For motion capture objects, in the Resources pane, click the Objects tab.
Vicon Tracker User Guide For use with Tracker 3.10 Page 18 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 19 of 205
21 March 2023, Revision 1
BEYOND MOTION
• In the Properties pane, click the Show Advanced link to view all of the
available properties.
• Click the Hide Advanced link to show just the basic properties.
• In the Properties pane, view or change the setting for the required property
using its entry field or control:
• Click the current color in the entry field to display the Select color dialog
box. In the Basic colors area, click the square for the required color, or in
the Custom colors area, define a new color.
• Click the drop-down arrow and select an entry from the list.
• Move the slider to the left to decrease the value or to the right to increase
the value displayed in the entry field.
• If you are working in the following areas of the Tracker window, save your
settings to the appropriate configuration file using the configuration
management controls:
• System tab
• View pane
Vicon Tracker User Guide For use with Tracker 3.10 Page 20 of 205
21 March 2023, Revision 1
BEYOND MOTION
Tip
To see a list of all current hot keys, on the Help menu, click Hotkeys.
Task Keys
Display the installed Vicon Tracker User Guide (PDF) F1
Display full screen view for the selected view pane F5
Display/Close Sounds dialog box F6
Display/Close Options dialog box F7
Create named object from selected reconstructions CTRL+E
Reboot Core Processor CTRL+R
Resynchronize the system CTRL+SHIFT+R
Save All CTRL+S
Pause Live/Play Offline Space
Redo CTRL+Y
Undo CTRL+Z
Select previous camera [
Select next camera ]
Unset all cameras' Bumped status CTRL+SHIFT+B
Translate object T
Rotate object R
Vicon Tracker User Guide For use with Tracker 3.10 Page 21 of 205
21 March 2023, Revision 1
BEYOND MOTION
Task Keys
Go to frame CTRL+G
Move to next frame Right arrow
Move to last frame Left arrow
Move to first frame Home
Move to last frame End
Move forward 10 frames PgUp
Move backward 10 frames PgDown
Vicon Tracker User Guide For use with Tracker 3.10 Page 22 of 205
21 March 2023, Revision 1
BEYOND MOTION
Zooming an axis (x or y)
All graph components in a single workspace maintain the same scale for both
the x-and y-axes. The x-axis is shared across all components, but each
component has its own y-axis. The y-axis may show different ranges, but
represent the same number of values.
On the x-axis, the workspace is centered around zero, keeping the zero on the
right edge of the workspace and changing the values displayed on the left.
Vicon Tracker User Guide For use with Tracker 3.10 Page 23 of 205
21 March 2023, Revision 1
BEYOND MOTION
After you have prepared your Vicon system and selected the objects for motion
capture in the Resources pane, you use the view pane to view the data.
Vicon Tracker User Guide For use with Tracker 3.10 Page 24 of 205
21 March 2023, Revision 1
BEYOND MOTION
• System tab: Enables you to configure the components of your Vicon system.
See About the System tab on page 29.
Vicon Tracker User Guide For use with Tracker 3.10 Page 25 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Calibrate tab: Enables you to calibrate your Vicon cameras. See About the
Calibrate tab on page 91.
Vicon Tracker User Guide For use with Tracker 3.10 Page 26 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Objects tab: Enables you to manage object files for the objects whose motion
data you want to track. See About the Objects tab on page 114.
Vicon Tracker User Guide For use with Tracker 3.10 Page 27 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Recording tab: Enables you to save and play back recordings of trial data. See
About the Recording tab on page 134.
• Resources lists: Enables you to select the nodes and any sub-nodes to be
configured. The components of this list depend on whether you are using the
System or Objects tabs.
• Properties pane: Enables you to view and change settings for the item
selected in the Resources list. See Setting properties in Tracker on page 18. The
contents of this pane depend on the node selected in the Resources list.
Vicon Tracker User Guide For use with Tracker 3.10 Page 28 of 205
21 March 2023, Revision 1
BEYOND MOTION
You manage the components of your Vicon system on the System tab. The
System tab may contain the following components:
Component Description
System You create, save, and manage configurations for the settings in the
configuration System Resources pane using the configuration management controls
management at the top of the pane.
System list You select the node for the system component you want to configure
in the System list:
• Local Vicon System The Vicon system capture rate and the
Tracker memory buffer size; real-time processing settings; and
the identification and connection settings for the Tracker host
PC.
• Vicon Cameras The identification and configuration settings for
each Vicon camera connected to your Vicon system.
• Vicon Connectivity The identification and configuration
settings for each Vicon Lock attached to your Tracker system.
• Devices The identification and configuration settings for any
analog or digital devices integrated into your Vicon system.
You view or modify system components in the Properties pane. The properties
displayed depend upon the node selected in the System list.
Vicon Tracker User Guide For use with Tracker 3.10 Page 29 of 205
21 March 2023, Revision 1
BEYOND MOTION
• On the System tab, right-click the Vicon Cameras node or Devices node and
then click Reorder.
In the Reorder Devices dialog box, choose from the following options:
Option Description
Move Up Moves the selected item up one position in the list
Move Down Moves the selected item down one position in the list
Sort Sorts the list of devices according to name and type.
Remembered devices are at the bottom of the list.
Clean Removes the entries for the devices that are not used or
referred to (Remembered devices) in the current session.
Revert Undoes all the changes you have made in this dialog box
since you last clicked OK.
Vicon Tracker User Guide For use with Tracker 3.10 Page 30 of 205
21 March 2023, Revision 1
BEYOND MOTION
The Local Vicon System node enables you to configure the Vicon system capture
rate and the amount of memory allocated to Tracker for motion capture, manage
the way Tracker is to produce real-time 3D representations of the objects whose
motion is being captured, and specify the identification and connection settings
for the Tracker host PC.
The Local Vicon System node is the top-level node that is displayed for the
Tracker host PC. This node contains sub-nodes for each device connected to
your Vicon system under the following nodes:
• Vicon Cameras
• Vicon Connectivity
• Devices
The node for the device designated as the Vicon system synchronization source
is highlighted in bold on the System tab in the Resources pane.
Vicon Tracker User Guide For use with Tracker 3.10 Page 31 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. In the Properties pane, view or change settings for the desired properties to
suit the needs of your motion capture application.
When you first set up your Vicon system, you must configure at least the
Requested Frame Rate (Hz) property.
3. In the configuration management section at the top of the tab, enter a name
and click the Save current configuration button to save your system
configuration settings.
Vicon Tracker User Guide For use with Tracker 3.10 Page 32 of 205
21 March 2023, Revision 1
BEYOND MOTION
You can also access related options from the Local Vicon System context
menu on page 45.
Note
Some settings are available only when advanced properties are
displayed (at the top right of the Properties pane, click Show
Advanced).
System section
On the System tab, when you click the Local Vicon System node, you can access
the following system-wide settings in the System section of the Properties pane.
These settings affect all the connected cameras and devices:
Vicon Tracker User Guide For use with Tracker 3.10 Page 33 of 205
21 March 2023, Revision 1
BEYOND MOTION
Setting Description
Requested The rate (in Hz) at which to synchronize the Vicon cameras and the
Frame Rate external video signal. Select from displayed values (multiples of the base
frame rate of the PAL, NTSC, or Film video standard specified in
Standard) up to a maximum of 2,000. The configured Vicon system
capture rate is displayed in square brackets beside the Local Vicon
System node. For example, if the Vicon system frame rate is set to 100
Hz, the node title is displayed as Local Vicon System [100Hz].
Actual Frame Displays the frame rate (in Hz) currently used by the system, as
Rate constrained by the limits of the camera frame rate.
Preferred Sync If multiple connectivity devices are present in the system, enables you to
Source select the connectivity device that is your preferred source for
synchronization. (If your system contains a Vicon Lock connectivity
device, this is automatically selected as the sync source.)
Reboot All Resets all the Vicon hardware devices in the Vicon system. Click this
button if a camera has failed to boot, or if you need to reset the whole
system. Alternatively, select Reboot Hardware from the context menu.
Real Time The number of frames (between 1 and 100) that make up the buffer
Buffer Size between the Vicon hardware and the processing engine. If set to 1,
(frames) latency is minimized. If set to a higher value, throughput is improved, but
latency is higher.
Low Jitter When selected, sets the Grayscale Mode for all cameras to Only, which
applies advanced centroid fitting and jitter reduction algorithms to
reduce data noise. Note that running in this mode increases sensitivity to
bandwidth limitations and its effectiveness is related to system size. For
more information, contact Vicon Support7.
7 mailto:[email protected]
Vicon Tracker User Guide For use with Tracker 3.10 Page 34 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click the Local Vicon System node, you can access
the following settings in the Genlock and Timecode section of the Properties
pane.
Setting Description
Genlock Standard The type of video standard supported by the connected video
source: None, PAL, NTSC, Film, 30Hz and VESA (for a complete list,
click the Genlock Standard list in Tracker).
The icon to the left of each option provides additional information
about the availability of that standard.
Note: The 30Hz option enables you to run the Vicon system at
multiples of 30 frames per second (above 50 fps), with timecode and
genlock capability at true 30 fps, and works with Vicon Locks.
However, note that for 30 fps support to work with Tracker, you must
upgrade the Vicon firmware to Bundle 500 or later.
Enable Genlock Select to enable synchronization.
Auto Genlock When selected, Tracker automatically selects a genlock standard and
enables synchronization based on currently detected signals.
Genlock Offset Specify the system offset relative to the genlock signal (expressed as
a fraction of the genlock frame period). Values are in the range 0–1
Note: For VESA modes, use VESA Offset (see below).
VESA Offset Specify the system offset relative to the VESA signal (expressed as a
fraction of the VESA frame period). The camera timing can be offset
by up to one VESA frame.
Note: Only applies when you have selected one of the VESA
standards from the Genlock Standard list.
Vicon Tracker User Guide For use with Tracker 3.10 Page 35 of 205
21 March 2023, Revision 1
BEYOND MOTION
Setting Description
Timecode Source Enables you to select the required timecode source. The Internal
Drop option determines whether the internal timecode source
generates a drop-frame timecode when the Genlock Standard is
NTSC.
Note: VITC and LTC always display a flat line if the system is not
genlocked. This is because these signal types can only be detected
by a sync source that is genlocked.
The icon to the left of each option provides additional information
about the availability of that standard:
Icon Meaning
Green If you select a mode with the blue wave icon and
square wave then select the Enable Genlock check box, the icon
turns green.
Vicon Tracker User Guide For use with Tracker 3.10 Page 36 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on the Local Vicon System node, the
following settings are available in the Object Tracking section of the Properties
pane.
Setting Description
Max Boot Iterations The maximum number of iterations allowed for the booting
algorithm. Increasing this parameter improves booting
quality, but has a (small) performance cost.
Entrance Threshold Minimum proportion of markers that must be visible to the
cameras before the object is booted. If it is less than this
value, the object is not booted.
Minimum Object Marker The minimum distance allowed between marker positions in
Separation order for them to be tracked separately.
Vicon Tracker User Guide For use with Tracker 3.10 Page 37 of 205
21 March 2023, Revision 1
BEYOND MOTION
Reconstruction section
On the System tab, when you click on the Local Vicon System node, the
following settings are available in the Reconstruction section of the Properties
pane.
Settings Description
Minimum Cameras to Start Controls how many cameras (rays) must see the same
Trajectory marker (centroid) to create a new reconstruction and
potentially form a new trajectory. The minimum value
that can create a reconstruction is two cameras. The
maximum value of this parameter is 50 camera rays. If
there are a large number of unlikely reconstructions
being created, increase this value.
Tip: In Tracker 3, the default value for this property is 3
(ie three cameras), so if you are using a two-camera
system, ensure you change the value to two before
starting to work with Tracker.
Environmental Drift Tolerance An uncertainty applied (in mm) to camera calibration to
take into account environmental factors such as
temperature change, that may cause drift in the
calibration. For larger volumes, increase this value; for
smaller volumes, decrease this value.
For advice about reducing the effect of environmental
factors, see Prepare the capture environment.
Reconstruction Minimum The minimum distance, specified as a value in the range
Separation 0–100 mm, allowed between 3D marker positions in
order for them to be considered for reconstruction. If
two candidate reconstructions are closer than this
minimum separation, only the most likely reconstruction
(in terms of the number of cameras contributing) will be
reported. The other will be discarded. A higher value
decreases the likelihood of creating spurious
reconstructions, but increases the possibility that some
genuine markers will not be reconstructed.
To disable this feature, set the value to 0.0.
Vicon Tracker User Guide For use with Tracker 3.10 Page 38 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on the Local Vicon System node, the
following settings are available in the UDP Object Stream section of the
Properties pane.
Setting Description
Enabled If selected, starts the UDP streaming of data. Unlike the
data stream, the UDP stream does not maintain client
connection information. If selected, data is output whether
or not there are any connected clients.
Data Block Size The size of the UDP datagrams (data blocks). Ensure the
value selected matches the expected value for the
datagram size in the client program.
Options are 256, 512, and 1024.
Object Per Port If cleared, all objects are output on the same port.
If selected, each object is output on its own UDP port. Port
assignments are made whether or not the object is active.
The following image shows how port numbers are
assigned:
Vicon Tracker User Guide For use with Tracker 3.10 Page 39 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on the Local Vicon System node, the
following settings are available in the VRPN Stream section of the Properties
pane:
Settings Description
Add Filtered Tracker If selected, adds a tracker (named <object>_2), with
One Euro filtering applied, to each object.
Translation Min Cut-Off Enables you to specify the frequency (Hz) below which
noise (translation motion) will not be filtered.
Translation Beta To avoid lag, you can set a value between 1 and 0 to
reduce filtration applied to the position of the object
where there is greater motion. 0 = filtering on all
translation motion; 1 = filtering on very slow translation
motion only.
Rotatation Min Cut-Off Enables you to specify the frequency (Hz) below which
noise (rotation motion) will not be filtered.
Rotation Beta To avoid lag, you can set a value between 1 and 0 to
reduce filtration applied to the rotation of the object
where there is greater motion. 0 = filtering on all
rotation motion; 1 = filtering on very slow rotation
motion only.
Vicon Tracker User Guide For use with Tracker 3.10 Page 40 of 205
21 March 2023, Revision 1
BEYOND MOTION
• On the System Resources tab, select Local Vicon System and in the Properties
pane, ensure the Advanced properties are displayed.
The data available for output is a subset of the data available using the
DSSDK.
Important:
To stream device data, you must give the device a name.
Vicon Tracker User Guide For use with Tracker 3.10 Page 41 of 205
21 March 2023, Revision 1
BEYOND MOTION
Property Description
Enabled Turns streaming on/off
IP Address Address used to create the outbound socket
Port Port number used to create the outbound socket
Buffer Size Size of the buffer to allocate to store a frame's worth of data
Subject Name If a single subject is loaded, this option enables you turn on/off
the subject name in the message address (see Packet contents on
page 43).
If multiple subjects are loaded, the subject name is always
included as part of the message address.
Enable Segments, Turn on/off specific data types
Markers, …
Vicon Tracker User Guide For use with Tracker 3.10 Page 42 of 205
21 March 2023, Revision 1
BEYOND MOTION
Packet contents
Each packet consists of a bundle containing one or more messages. Each
message has an address associated with it to identify its contents. The /vicon/
frame message is always generated; other messages may or may not be present,
depending on the output data types selected.
Vicon Tracker User Guide For use with Tracker 3.10 Page 43 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 44 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you right-click on the Local Vicon System node, you
can select the following options from the context menu:
Option Description
Reboot Hardware Reset all of the Vicon hardware devices in the Vicon
system. Use this command if a camera has failed to
boot, or if you need to reset the whole system for other
reasons.
Alternatively, use the Reboot All button in the System
section of the Properties pane.
Reboot Core Processor Restarts the Core Processor and resets the labeler.
Alternatively, press CTRL+R.
Resynchronize Forces the Vicon system synchronization source to
resynchronize the frame rate for all connected cameras
and third-party devices.
Vicon Tracker User Guide For use with Tracker 3.10 Page 45 of 205
21 March 2023, Revision 1
BEYOND MOTION
You manage the identification and configuration settings for each Vicon camera
connected to your Vicon system with the Vicon Cameras node.
Configuring Vicon cameras ensures that all the camera settings are correct and
appropriate for your motion capture application. You can configure the settings
for an individual camera, several cameras, or all cameras at once.
Vicon Tracker User Guide For use with Tracker 3.10 Page 46 of 205
21 March 2023, Revision 1
BEYOND MOTION
This node is displayed under the Local Vicon System node. The Vicon Cameras
node lists each Vicon camera connected to your system. For each camera, the
node name includes:
• The camera type listed in parentheses, for example, #1 Over Door (Vantage 8)
Vicon Tracker User Guide For use with Tracker 3.10 Page 47 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. From the view pane tool bar, select Camera. The 2D data being captured by
each Vicon camera selected in the Resources pane in the System list is shown
in a separate Camera view pane.
• In the Options dialog box, under the General View Options section, select
the Target Volume option. In the Camera view pane tool bar, from the View
drop-down list, select 3D Overlay. A virtual representation of your target
volume is overlaid on the 2D data from the camera image.
3. In the System list in the Resources pane, select the Vicon camera node whose
properties you want to configure.
4. In the Properties pane, view or change settings for the relevant properties.
When you first set up your Vicon system, you must configure at least the
following properties in the order shown.
Important
These properties affect the quality of the motion capture data.
Therefore, it is important to optimize them before you collect data
intended for later analysis. In subsequent sessions, you may want to
configure additional properties to suit the needs of your motion
capture application.
Vicon Tracker User Guide For use with Tracker 3.10 Page 48 of 205
21 March 2023, Revision 1
BEYOND MOTION
6. When you have finished adjusting the Vicon Camera properties, in the
Settings area, ensure that Grayscale Mode is set to Auto.
7. At the top of the System tab, click the Save current configuration button
Vicon Tracker User Guide For use with Tracker 3.10 Page 49 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. In the Resources pane, ensure Live mode is activated (ie that Go Offline is
displayed).
3. On the System tab, expand the Vicon Cameras node and select the required
camera.
4. In the Properties pane at the bottom of the System Resources tab, go to the
Settings section and set Grayscale Mode to All.
5. Right-click and drag in the Camera view pane to zoom in on the target marker
pair.
6. If the image of the markers is not bright enough to allow confidence in the
level of focus achieved, increase the intensity of the grayscale from the
camera. To do this, in the Properties pane, ensure Advanced properties are
displayed and in the Settings section, increase the value for Gain to a level
above x1.
7. In the Camera view pane, observe the sharpness of the image of the markers.
8. After focusing the lens, return Tracker to its default capture settings. In the
Properties pane at the bottom of the System Resources tab, set Grayscale
Mode to Auto.
Vicon Tracker User Guide For use with Tracker 3.10 Page 50 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
Preview mode is for system setup purposes only. You cannot use
Preview mode when you are calibrating, auto masking, capturing, or
reviewing data.
1. In the View pane, select the Camera view type (see Step 1 in Check camera
lens focus on page 50).
2. On the System tab, right-click on Vicon Cameras and select Enable Preview
Mode.
• Open the aperture. When you have finished checking the camera aim and
field of view, be sure to set the aperture back to its original value.
All supported cameras can use Preview mode but their performance is
dependent on frame rate.
• Valkyrie cameras support Preview mode from 30–900Hz. At frame rates above
a Valkyrie camera's full frame rate (see Tracker 3.10 new features and
functions), Preview mode uses windowing to display the same field of view as
optical mode.
• Vantage and Vero cameras support Preview mode from 30–60Hz. At frame
rates above this, an image may be displayed but this has not been tested.
Vantage and Vero do not use windowing.
Vicon Tracker User Guide For use with Tracker 3.10 Page 51 of 205
21 March 2023, Revision 1
BEYOND MOTION
You can also access related options from the Vicon Cameras context menu on
page 67.
Vicon Tracker User Guide For use with Tracker 3.10 Page 52 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following controls are available in the Identification section of
the Properties pane:
Control Description
Name A user-defined display name for the entire set of Vicon
cameras or for each individual Vicon camera. For example, if
a camera is placed over a door, you could name it Over Door.
Device ID The unique identification number Vicon assigns to each Vicon
camera during manufacture. The top-level entry for all Vicon
cameras is read-only.
Vicon Tracker User Guide For use with Tracker 3.10 Page 53 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
The above illustration shows the Settings section for a Vicon Vantage
camera. The Settings section for other Vicon cameras displays slightly
different options.
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following controls are available in the Settings section of the
Properties pane.
Vicon Tracker User Guide For use with Tracker 3.10 Page 54 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Enabled Whether or not the Vicon camera is currently enabled for use. Default is
selected.
Enable Whether or not the strobes on the camera are used (does not affect the
Strobe shutter period). Default is selected.
Strobe The amount of light emitted by camera strobe units. This value can be set
Intensity between 0-1 to minimize reflections and obtain clear marker images. The
higher the setting, the brighter the markers appear, but this may cause
blobs to be produced from reflections from other strobes. Lower settings
make the markers themselves less visible to the cameras.
In almost all circumstances, you will want to keep the intensity at its
maximum level because the system works by recording light from the
strobes that is reflected from the markers, thus the more light the strobes
send out the more light the markers reflect. However, if you are capturing a
very fast moving object you may achieve better results by reducing the
strobe intensity. The strobe intensity affects the time the strobe is on for
each camera frame. The full strobe intensity corresponds to 1ms for normal
frame rates. Lower strobe intensities mean that the markers are captured
with the strobes on for less time and, therefore, have less time to move
during the frame.
Tip: It is advisable to use full strobe intensity and deal with reflection
problems by closing the camera lens aperture. Adjust this setting and the
Threshold setting until reflections are minimized or gone.
For further tips on setting Strobe Intensity, see Setting up a mixed Vicon
camera system on page 12.
Sensor Tracker 3.9 and later supports the use of the Vantage+ firmware
Mode upgrade, enabling you to use High Speed mode on your Vantage cameras
without having to change the field of view (FOV) or lens. When you capture
optical data, subsampling (selectively reducing the pixel count) enables you
to run at high camera frame rates without reducing the FOV (frame size).
In High Speed mode, you can run your Vantage cameras at higher frames
rates while maintaining the FOV. You can change frame rates during
capture and you do not need to set up your cameras again when you
increase the frame rate, as the FOV is unchanged.Because the higher
speeds are achieved through subsampling (removing some pixels from the
frames), some reduction in resolution is incurred.
For details, see High-speed mode in the Vicon Vantage Reference Guide.
Note: Valkyrie cameras do not support the use of High Speed mode.
Vicon Tracker User Guide For use with Tracker 3.10 Page 55 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Gain The amplification of the pixel value. Select a displayed value to determine
the intensity of the grayscale from the Vicon cameras: x1, x2, x4, or x8.
(Note that the available values are those supported by the camera.)
This setting is applied to the camera to change the dynamic range of the
recorded image. Increasing the Gain means that the marker has less
variation in grayscale intensity between its center and its edge, but in
certain circumstances, using a higher gain yields markers that are easier for
the camera to distinguish.
Adjust this setting if the markers appear too faint or if the cameras have
trouble distinguishing them; otherwise, leave the this property at the
default x1 setting.
Grayscale The type of data for processed grayscale blobs that the Vicon cameras
Mode send to Vicon Tracker. (Note that this mode is disabled if Low Jitter mode
is selected.) The Vicon cameras perform data processing to create 2D data
for Vicon markers. They generate grayscale blobs for reflections from
objects in the capture volume and then use centroid-fitting algorithms to
determine which of these are likely to be markers by comparing the shape
of the grayscale blobs to the Minimum Circularity Ratio and Maximum Blob
Height settings. During this processing, Vicon cameras can produce the
following types of data for grayscale blobs: centroids data (x, y coordinates
and the radius of the centroid calculated), grayscale data (pixel and line
information), or coordinates data (line information, that is, grayscale data
without pixel values).
You can specify which type of processed data Vicon cameras send to
Tracker:
Auto Send grayscale data only of the grayscale blobs for which
centroids were not generated, that is, those below the threshold
specified for Minimum Circularity Ratio.
Send coordinates data of grayscale blobs for which one or more
line segments, or the total number of lines in the blob, exceeds
the value set for Maximum Blob Height.
If a marker can be centroid fitted by the camera, the centroid is
passed to the capture PC. If it cannot, the full grayscale of the
image is sent, allowing the data to be post-processed on the PC.
This is the default and recommended mode.
Tip: If any optical camera does not capture wand data during a
wand wave, select the relevant camera on the System tab and
look in the Settings section of the Properties pane to ensure you
have set the Grayscale Mode to Auto.
None Send no grayscale data; send only centroid data (i.e, x, y, and
radius data).
Any ambiguous grayscale data will be discarded.
Vicon Tracker User Guide For use with Tracker 3.10 Page 56 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
All Send grayscale data both of grayscale blobs for which centroids
were generated and of those for which centroids were not
generated, that is those below the threshold specified for
Minimum Circularity Ratio.
Send coordinates data of grayscale blobs for which one or more
line segments, or the total number of lines in the blob, exceeds
the value set for Maximum Blob Height.
Select this setting if you need to see exactly where the camera
calculates the centroid with respect to the grayscale marker
image, for example when adjusting parameters. This setting
results in much larger data rates and files; it may be useful for
diagnostic purposes, but do not use it in normal capture
situations.
Only Send all grayscale and coordinates data; send no centroid data.
This setting is useful when focusing or making other adjustments
to the cameras themselves as you see exactly the image
recorded on the sensor.
Edges Send only edge coordinates data; send no centroid or grayscale
data.
If data rates are very high, for example when there are too many
reflections, the camera automatically enters this mode. Use this
setting to manually force the camera into this mode.
No Send grayscale data both of grayscale blobs for which centroids
Edges were generated and of those for which centroids were not
generated; send no coordinates data.
Use this setting to prevent the Vicon camera from sending edge
coordinates.
Caution: Even if you have not specified a Grayscale Mode
setting that would have coordinates data sent to Tracker, a
Vicon camera automatically sends coordinates data – either
temporarily or permanently – if it is overloaded with data (e.g.,
too many markers, too many reflections, hand or reflective
objects immediately in front of the camera, too low a threshold
or too high a gain). If a camera automatically starts to present
coordinates data, identify the source of the overload and
attempt to remedy it.
Enable When selected, the status lights on the Vicon camera strobe unit provide
LEDs feedback on the status of the camera. For more information, see the
documentation that was supplied with your Vicon camera.
Enable (Vicon Valkyrie and Vantage only) When selected, the display on the
Display camera provides feedback on the status of the camera. For more
information, see the documentation available on the Vicon documentation
website8.
8 https://docs.vicon.com
Vicon Tracker User Guide For use with Tracker 3.10 Page 57 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Enable Tap (Vicon Valkyrie and Vantage only) When selected, you can lightly tap the
to Select camera in the volume to select it (and deselect the other cameras).
Note that when Enable Accelerometry is selected (see below), if you tap a
calibrated camera too hard, its status LEDs and display (if enabled) indicate
that it has been 'bumped'.
You can remove the camera's bumped status in Tracker. If this is a frequent
occurrence, you can change its sensitivity to being tapped by reducing the
Bump Detection Sensitivity.
For information on removing a camera's bumped status and changing
Bump Detection Sensitivity, see Camera Status section on page 61.
Enable (Vicon Valkyrie and Vantage only) When selected, the display on calibrated
Accelerome cameras changes to alert you when they have moved from their calibrated
try positions, eg, if a camera has been knocked.
In Tracker, the camera's Bumped check box (in its Status properties)
displays a check mark.
For information on removing a camera's bumped status and changing
Bump Detection Sensitivity, see Camera Status section on page 61.
(This setting also turns on or off the auto-rotation of the display on the
cameras.)
For more information on Vicon camera accelerometers, see the
documentation for your Vicon camera, which is available on the Vicon
documentation website9.
9 https://docs.vicon.com
Vicon Tracker User Guide For use with Tracker 3.10 Page 58 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following controls are available in the Centroid Fitting section
of the Properties pane:
Control Description
Threshold The minimum brightness (intensity) for markers; pixels of an intensity
lower than this threshold are ignored. This value can be set between
0-1 to determine the pixels to be considered for centroid fitting
onboard the Vicon cameras. Lower settings enable the camera to
detect lower light levels, thus making the markers appear larger, but
may pick up unwanted reflections and other light sources. Higher
settings reduce the noise, but make the markers themselves less
visible.
This setting differentiates between markers and ambient light. A Vicon
camera records 10-bit grayscale data, which for each sensor pixel is a
measure of how much light fell on that pixel during a given amount of
time. However, the cameras will almost always pick up some ambient
light in the volume. To enable the cameras to distinguish between light
that comes from markers and light that does not, a threshold is
applied. Anything above this threshold is deemed to be a marker,
anything below is deemed to be ambient light. A value in the region of
0.2 to 0.5 is usually appropriate, but Vicon strongly recommends that
you use static markers in the volume in order to establish an
appropriate setting. If cameras are evenly spaced around the volume,
the same threshold value is usually sufficient for all cameras.
Adjust this setting, the Strobe Intensity, and the camera's aperture
until reflections are minimized or gone.
Tip: To help you to determine the most effect threshold setting for
grayscale blobs, you can set the background color of the Camera view
pane to the value of the Threshold control in the Centroid Fitting
section of the Properties pane. To do this, open the Options dialog
box (F7), and in the General View Options, select Threshold.
Vicon Tracker User Guide For use with Tracker 3.10 Page 59 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Minimum The circularity threshold used by the centroid-fitting algorithms in a
Circularity Ratio Vicon camera. (Note that this mode is disabled if Low Jitter mode is
selected.)
This value can be set between 0-1 to determine how similar a grayscale
blob must be to the internal model of a marker – that is a radially
symmetric object that has smooth, sharp edges and whose pixel
intensity is brightest at the center and gradually fades towards the
edges. The Vicon cameras consider grayscale blobs with circularity
equal to or greater than this threshold to be well-formed, circular
marker images. The higher the value, the more stringent the centroid
fitter is; the lower the value, the less stringent the centroid fitter is. You
may want to apply higher settings for camera calibration to ensure that
Tracker selects the best markers and thus provides the best possible
calibration. A lower value may be appropriate for data capture.
Maximum Blob The maximum number of pixels per line that a grayscale blob can
Height contain in a horizontal line. If the number of pixels exceeds this value,
the Vicon camera determines that the grayscale blob is not a marker,
stops processing it, and discards the pixel values (it preserves just the
coordinates data, which can be sent to Vicon Tracker, depending on
the Grayscale Mode setting).
Set this value between 0–77500 to determine how large a grayscale
blob can be for a Vicon camera to consider it a candidate marker. The
Vicon cameras consider grayscale blobs with horizontal lines
containing this number or fewer pixels to be good-sized, circular
marker images. The higher the value, the larger a grayscale blob can
be; the lower the value, the smaller a grayscale blob must be.
Vicon Tracker User Guide For use with Tracker 3.10 Page 60 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Enable Centroid When selected, enables the camera's onboard centroid tracking
Tracking algorithm.
Note: Applies only to Vicon cameras that have the ability to process
this information on board the camera.
Default: Off
Marker Velocity Maximum velocity at which a marker is tracked, expressed as the
percentage of image width per second.
Default: 5
Note
The above illustration shows the Status section for a Vicon Vantage
camera. The Status section for other Vicon cameras may display
different options.
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following controls are available in the Status section of the
Properties pane.
Vicon Tracker User Guide For use with Tracker 3.10 Page 61 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Connected Whether or not the Vicon camera is currently connected to the Vicon
system.
Sync Source Whether or not the Vicon camera is designated as the synchronization
source for the Vicon system. (Not relevant for systems containing a
Vicon Lock)
Contributing Whether or not the Vicon camera is contributing centroid data during
Centroids the current motion capture.
Contributing Whether or not there is a socket open to the Vicon camera capable of
Grayscale receiving grayscale. This socket may be dropped when the system is
under heavy load, therefore this property is useful as a system status
monitor. It is not related to Grayscale property in Settings.
Contributing Whether or not the Vicon camera is contributing tracks (that is, labeling
Tracks centroids between frames) during the current session.
Bumped Indicates the whether the Vicon Valkyrie or Vantage camera has moved
from its calibrated position.
You can remove the Bumped status for:
• A selected camera: Clear the Bumped check box.
• All cameras: Press Ctrl+Shift+B
Bump Detection Enables you to change the sensitivity of the Vicon Valkyrie or Vantage
Sensitivity camera's accelerometer (also see Enable Accelerometry in Camera
Settings section on page 54).
Vicon Tracker User Guide For use with Tracker 3.10 Page 62 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
The above illustration shows the Hardware section for a Vicon Vantage
camera. The Hardware section for other Vicon cameras may display
different options.
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following controls are available in the Hardware section of the
Properties pane.
Setting Description
Type The type of Vicon camera. For a Vicon Cameras node, this setting is
read-only.
Strobe Type The type of strobe unit attached to the front of the Vicon camera:
Visible Red (VR), Near Infrared (NIR), or Infrared (IR).
For a Vicon Cameras node, this setting is read-only.
Strobe Temp Displays data from Vicon Vantage strobe onboard sensor both as a
numeric indicator (in degrees Celsius) and a colored temperature
indicator. The color of the indicator changes to reflect a change in
temperature: yellow (warming up to the temperature specified by the
lower bounds), green (between the specified upper and lower bounds)
or red (overheated above the upper bounds).
To set values that are representative of your laboratory environment,
you can change the upper and lower bounds of the temperature
range. To do this, select the Camera Temperature Range option in the
Options dialog box (F7).
Vicon Tracker User Guide For use with Tracker 3.10 Page 63 of 205
21 March 2023, Revision 1
BEYOND MOTION
Setting Description
Camera Body Displays data from Vicon Vantage camera body onboard sensor. See
Temp 1 Strobe Temp above.
Camera Body Displays data from Vicon Vantage camera body onboard sensor. See
Temp 2 Strobe Temp above.
Sensor Width The width (in pixels) of the Vicon camera sensor.
Sensor Height The height (in pixels) of the Vicon camera sensor.
Revision Camera revision number.
MAC Address The Media Access Control (MAC) address assigned to the Vicon
camera during manufacture. This is a hexadecimal value in the format
##.##.##.##.##.##.
For a Vicon Cameras node, this setting is read-only.
Serial Number Vicon Vantage camera's serial number (if set)
IP Address The Internet Protocol (IP) address assigned to the Vicon camera on the
Vicon Ethernet network.
For a Vicon Cameras node, this setting is read-only.
Destination IP The network adapter IP address to which data from this camera will be
Address sent.
Vicon Tracker User Guide For use with Tracker 3.10 Page 64 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, these controls are available in the Firmware section of the
Properties pane:
Control Description
Firmware The version number of the Vicon firmware currently installed on the
Version Vicon camera.
Firmware Whether or not the currently installed Vicon firmware is complete. If
Complete not, you can reprogram the firmware.
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following controls are available in the Calibration section of
the Properties pane:
Control Description
Reset Reset calibration of selected camera(s)
Calibration
Focal Length The camera lens focal length value of the selected camera(s) in mm.
(mm)
Vicon Tracker User Guide For use with Tracker 3.10 Page 65 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on a Vicon Cameras node or an individual
camera node, the following command is available in the Commands section of
the Properties pane:
Command Description
Reboot Stop and restart all cameras or the selected Vicon camera.
Vicon Tracker User Guide For use with Tracker 3.10 Page 66 of 205
21 March 2023, Revision 1
BEYOND MOTION
Option Description
Reorder Display the Reorder Devices dialog box. This enables you to change
the order in which Vicon cameras are displayed in the System
Resources list.
Reboot All Stop and restart all the Vicon cameras in the system.
Cameras
Remove Vicon Displays a choice of Disconnected or Missing:
Cameras
• Disconnected - removes cameras that are currently unplugged.
• Missing - removes cameras that are unplugged, but were
previously used in a calibration.
Enable Preview Displays a video image from the optical sensor of Vicon cameras that
Mode offer this option. This enables you to aim cameras more quickly and
easily and to check volume coverage by the cameras during setup.
Note: The preview feature is for system setup purposes only. You
cannot use Preview mode when you are calibrating, auto masking,
capturing, or reviewing data.
For information on how to use Preview mode, see Check camera aim
and field of view on page 51.
When you right-click on a node for a specific Vicon camera, you can select the
following option from the context menu:
Option Description
Reset Resets the camera calibration
Calibration
Reboot Stop and restart the selected Vicon camera.
Vicon Tracker User Guide For use with Tracker 3.10 Page 67 of 205
21 March 2023, Revision 1
BEYOND MOTION
The Vicon Connectivity node is displayed under the Local Vicon System node
when Vicon Tracker is connected to the Vicon system. The Vicon Connectivity
node lists each Vicon connectivity unit connected to your Vicon system.
Depending on the type of Vicon system under which you are running Vicon
Tracker, your Vicon system architecture will contain one or more of the following
Vicon connectivity units:
Note
Except where noted, references to Vicon Lock, Lock units, and Lock
apply to all current models of the Vicon Lock unit (at the time of
publication, this includes Vicon Lock Studio and Vicon Lock Lab).
Vicon Tracker User Guide For use with Tracker 3.10 Page 68 of 205
21 March 2023, Revision 1
BEYOND MOTION
The use of Vicon Lock is supported for current Vicon camera systems.
This node is displayed under the Local Vicon System node when Vicon Tracker is
connected to a Vicon system with at least one Vicon Lock unit. The Vicon
Connectivity node lists each Vicon Lock unit connected to your Vicon system.
• Vicon Lock Lab Quick Start Guide (PDF) or Vicon Lock Studio Quick Start
Guide (PDF), available from the Vicon documentation website10.
Note
Except where noted, references to Vicon Lock, Lock units, and Lock
apply to all current models of the Vicon Lock unit (at the time of
publication, this includes Vicon Lock Studio and Vicon Lock Lab).
10 https://docs.vicon.com
Vicon Tracker User Guide For use with Tracker 3.10 Page 69 of 205
21 March 2023, Revision 1
BEYOND MOTION
You can also access related options from the Vicon Lock context menu on page 72.
Note
Except where noted, references to Vicon Lock, Lock units, and Lock
apply to all current models of the Vicon Lock unit (at the time of
publication, this includes Vicon Lock Studio and Vicon Lock Lab).
Setting Description
Name A user-defined display name for the Vicon Lock.
Type The Lock type is read-only.
Device ID The Device ID is read-only.
Setting Description
Enabled Whether or not the Vicon Lock is currently enabled for
use.
Sync Source The Vicon Lock automatically becomes the
synchronization source for the Vicon system.
Vicon Tracker User Guide For use with Tracker 3.10 Page 70 of 205
21 March 2023, Revision 1
BEYOND MOTION
For further information, see the relevant Vicon Lock Quick Start Guide (PDF). For
up-to-date information about the types of GPO triggers that are supported,
contact your local Vicon Support office (for Vicon contact details, see Contact
Vicon on page 205).
Vicon Tracker User Guide For use with Tracker 3.10 Page 71 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
Except where noted, references to Vicon Lock, Lock units, and Lock
apply to all current models of the Vicon Lock unit (at the time of
publication, this includes Vicon Lock Studio and Vicon Lock Lab).
If a Vicon Lock is connected to your Vicon system, when you right-click on the
Vicon Connectivity node on the System tab, you can select the following options
from the context menu:
Option Description
Reorder Display the Reorder Devices dialog box in which you
can change the order in which Vicon Lock units are
displayed on the System tab.
Reboot All Vicon Locks Stop and restart all of the Vicon Lock units in the
Vicon system.
When you right-click on a node for a specific Vicon Lock, you can select the
following options from the context menu:
Option Description
Reboot Stop and restart the selected Vicon Lock.
Reset Timecode Reset the Timecode to 00:00:00:00.
Vicon Tracker User Guide For use with Tracker 3.10 Page 72 of 205
21 March 2023, Revision 1
BEYOND MOTION
You can only use an additional device if you have the required license. To check
your current licensing options, from the Help menu, click About Vicon Tracker
and in the window, click the Feature Details button. After a few seconds, the
currently licensed options are listed. To change your licensing options, contact
Vicon Support11.
Depending on the type of additional licenses you are using with Tracker and
your Vicon system, it may contain one or more of the following additional
devices:
• Analog device such as accelerometers (see Set up analog devices on page 74)
11 mailto:[email protected]
Vicon Tracker User Guide For use with Tracker 3.10 Page 73 of 205
21 March 2023, Revision 1
BEYOND MOTION
Analog devices such as accelerometers are connected to the Vicon system via a
Lock Lab. You add analog devices to the Vicon system by right-clicking on the
Devices node and selecting Add Generic Analog.
The Generic Analog node lets you select the options for your device.
You can only use an analog device with Tracker if you have the required license.
For more information, contact Vicon Support12.
To use an analog device with Tracker:
1. Ensure that the analog device is connected to your Vicon system through a
Lock Lab.
3. Right-click Generic Analog and from the list, select your analog device.
4. To add outputs for the device, on the System tab, right-click the device and
click the number of components to add.
5. To change the properties of the output, edit the appropriate property in the
Properties pane, for example:
• Name
• Channel gain
6. To change the options for viewing data in the Graph view, in the view pane,
select Graph and then choose the appropriate option from the menu.
Tip
You can receive the raw analog data and relevant device information
through the DataStream SDK.
12 mailto:[email protected]
Vicon Tracker User Guide For use with Tracker 3.10 Page 74 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 75 of 205
21 March 2023, Revision 1
BEYOND MOTION
Restrictions:
• Tobii integration is for only Tobii Pro Glasses 2 and Tobii Pro Glasses
3.
• For Tobii Pro Glasses 2, the use of only one pair of glasses at a time is
supported.
• For Tobii Pro Glasses 3, the use of multiple devices is supported, but
has received limited testing. For details on how to integrate multiple
devices, please contact Vicon Support13.
• For a combination of Tobii Pro Glasses 2 and 3, you can use one pair
of Tobii Pro Glasses 2 with multiple pairs of Tobii Pro Glasses 3.
To include Tobii Pro Glasses in your Vicon Tracker system, complete these
procedures:
For details of Tobii Pro Glasses properties, see Tobii Pro Glasses node.
Before you begin, ensure your Vicon Tracker system is calibrated and that you
placed markers on the glasses and can track the glasses as an object.
Terminology
For Tobii Pro Glasses 2, the controller software is called 'Tobii Pro
Glasses Controller software'. For Tobii Pro Glasses 3, the equivalent
software is called 'Glasses 3'. In the following instructions, the term
'Tobii Glasses software' is used to refer to both versions.
13 mailto:[email protected]
Vicon Tracker User Guide For use with Tracker 3.10 Page 76 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. Follow the instructions provided by Tobii. The quick start guide provided in
the Tobii Pro Glasses box provides instructions on preparing and connecting
the glasses to the recording unit.
2. To use Tobii Glasses software, connect the Tobii Pro Glasses, either through
Ethernet or WiFi, by following the instructions provided by Tobii.
When setting up networking connection properties for an Ethernet port,
ensure that you select the required option:
• For Tobii Pro Glasses 3, you can select Internet Protocol Version 4 or
Internet Protocol Version 6
Note
Note that the recording unit requires batteries. Ensure you allow
sufficient charging time, using the supplied battery charger. The
recording unit requires only one battery, but takes 5+ hours charging
time for a full charge.
Vicon Tracker User Guide For use with Tracker 3.10 Page 77 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
Before attempting to connect Tobii Pro Glasses 3, ensure that you
installed Bonjour, which is an option (selected by default) when you
install Tracker, and that the Bonjour service is running (Task Manager >
Services > Bonjour Service).
Connection may take up to 20 seconds, as Bonjour broadcasts the
available services at intervals.
If you need to start the Bonjour service after you've added the Tobii Pro
Glasses in Tracker, either remove and add the device again or restart
Tracker after the service has been restarted.
For information on integrating Tobii Pro Glasses into Vicon Tracker, see these
topics:
Vicon Tracker User Guide For use with Tracker 3.10 Page 78 of 205
21 March 2023, Revision 1
BEYOND MOTION
If you don't need to connect the Tobii Pro Glasses 3 via WiFi , you can now add
the Tobii glasses into Tracker on page 81.
c. Click Apply.
Important
With this method, whenever the Tobii is powered down, it resets to the
default WiFi configuration. You must reconnect to the device (via
direct WiFi or an Ethernet connection) and choose the correct WiFi
configuration each time the recording unit is powered on.
Vicon Tracker User Guide For use with Tracker 3.10 Page 79 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
This option, while allowing connection to the recording unit for
configuration purposes, does not provide the neccessary Zeroconf
services, which are used by Tobii Pro 3 Glasses to advertise their
availability on the network. Do not use this method to add the device
into Vicon Tracker as it will not be found.
• Under the wired network settings at the bottom of the page, change the
profile to default-link-local and click Apply; or
• Configure the Tobii to be a DHCP server.
Vicon Tracker User Guide For use with Tracker 3.10 Page 80 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. Ensure the Tobii recording unit is connected to the Vicon Tracker computer
via Ethernet or WiFi (see Connect a Tobii recording unit to the Vicon Tracker
computer on page 79).
2. Ensure that the Tobii glasses are being worn by a subject in the volume.
(Tobii glasses connect to Vicon Tracker only when the glasses are worn: if no
eye is detected, the device is gray in the System Resources tree.)
3. In the System Resources tree, right-click Devices, point to Add Digital Device
and then select Add Tobii Pro Glasses 2 or Add Tobii Pro Glasses 3.
With Tracker 3.9 and later, when you first create a Tobii Pro 3 or Tobii Pro 2
device, a dialog box is displayed.
• Accept, do not show again – No further dialog boxes are displayed until a
later version of Tracker is used.
• Cancel – No device is created and the dialog box is displayed again if you
try to create a new Tobii device.
If you select either of the Accept options, Vicon Tracker searches for the
glasses on the network. When the glasses are discovered, data begins
streaming in Tracker.
This process may take some time.
Vicon Tracker User Guide For use with Tracker 3.10 Page 81 of 205
21 March 2023, Revision 1
BEYOND MOTION
4. With the Tobii Pro Glasses device selected in the System tree, in the
Properties pane, ensure that in the Sampling Rate field, the required sample
rate is selected.
5. Before capturing data, for each object, perform a calibration on each set of
glasses in the same way as in the Tobii Glasses software.
a. Instruct the subject to look at the calibration card, with the card held
between 0.5 m and 1.5 m from the subject (for correct placement of the
card, see the Tobii documentation).
b. In the System Resources tree, ensure the required Tobii Pro Glasses
device is selected and in the Properties pane, go to the Calibration
section and click Start Calibration.
Vicon Tracker User Guide For use with Tracker 3.10 Page 82 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note that, for Tobii Pro Glasses 2, data that is needed for
calibration is created on the SD card and is deleted when the
device is deleted. If the connection is lost, projects and participants
may be left on the SD card.
If no data is received for approximately one second, it is assumed
that the connection has been lost and the device reverts to
'discovery' mode to try to re-connect to the device when it
becomes available again.
6. The Tobii Pro Glasses 3 mocap integration kit is provided as two marker tree
attachments.
Attach the mocap integration kit by screwing it into the fittings on the frame
of the glasses.
The Vicon Tracker installer provides two VSKs for the two variants of these
marker trees. If you require more objects, you can interchange the left/right
trees from each of these two sets. For additional VSKs, contact Vicon
Support14.
14 mailto:[email protected]
Vicon Tracker User Guide For use with Tracker 3.10 Page 83 of 205
21 March 2023, Revision 1
BEYOND MOTION
7. Load the appropriate VSK. The relevant VSKs for the version of the integration
kit provided in your Tobii Pro Glasses box are found in:
C:\Program Files\Vicon\Tracker3.#\ModelTemplates
8. To visualize the gaze data in the Tracker workspace, with the Tobii Pro
Glasses device selected in the System tree, go to the General section of the
Properties pane and set the Glasses Object (left image) to the name of the
object that was assigned to the glasses (right image).
Vicon Tracker User Guide For use with Tracker 3.10 Page 84 of 205
21 March 2023, Revision 1
BEYOND MOTION
• The eye itself also rotates to match the Left/Right Gaze value, though this
may be difficult to observe.
For details of the resulting data that is reported by Tracker, see Understand
output data on page 85.
• There are multiple possible calibration targets (multiple cards or objects that
look like cards, or the card is visible in the displayed video that is also in view).
• Left(Right) Eye X, Y, Z position of the eye with respect to the origin of the
glasses segment/scene camera and the diameter of the pupil
Vicon Tracker User Guide For use with Tracker 3.10 Page 85 of 205
21 March 2023, Revision 1
BEYOND MOTION
The Dikablis Eye Tracking System is compatible with both T-Series and Bonita
cameras. A minimum of two cameras are required for use with the system.
Vicon Tracker User Guide For use with Tracker 3.10 Page 86 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Calibrate the Dikablis system and connect it to your Vicon system on page 87
• Calibrate your Vicon system and add in your Dikablis device on page 88
2. Ensure the subject is wearing the Dikablis headset and some markers for head
tracking.
3. Start the Dikablis Recorder software on the Dikablis system and run the
calibration wizard.
4. Connect the Dikablis laptop directly to your Vicon system PC with an Ethernet
cable.
Vicon Tracker User Guide For use with Tracker 3.10 Page 87 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. Calibrate the cameras in Tracker (see Calibrate Vicon cameras on page 93).
3. Set your origin pointing forwards by positioning the T of the wand with the
flat part (the top of the T) facing towards the front of the capture volume.
4. When you have a calibrated system, create an object in Tracker from the
wand markers. To do this:
a. In the Resources pane, click the Objects tab and ensure that in the Object
Tracking Mode section at the bottom of the tab, Track mode is not
selected. This enables you to see unlabeled reconstructions in the 3D
Perspective view pane.
Tip
Viewing unlabeled reconstructions requires additional processing,
so for lowest output latency, when you have finished creating
objects, click the Track button to change to Track mode. When
Track mode is selected, the Track button is green.
c. In the Resources pane, click the Objects tab and in the Create Object box,
type Wand and then click Create .
5. Adjust the wand's origin so it is on the center marker on the cross of the T.
6. With your subject looking straight ahead, create an object from the head
markers and give it a suitable name, such as Head. (You can give it any
suitable name, but ensure you use the same name in the following steps.)
7. On the System tab, right-click Devices, point to Add Digital Device, and then
click Add Dikablis Eye Tracker.
8. Select Dikablis Eye Tracker and in the Properties pane, enter the values:
• Name: Eye
• IP Address: 10.0.0.1 (or the address of the PC running the Dikabilis software
if different from 10.0.0.1)
• Calibration Object: Wand
Vicon Tracker User Guide For use with Tracker 3.10 Page 88 of 205
21 March 2023, Revision 1
BEYOND MOTION
9. Make sure the Eye Tracker remains selected on the System tab, change the
view pane to Graph view and in the Components list, select Components.
Two graphs are shown: X and Y, representing the 2D coordinates for the eye's
gaze. The values are pixel values from the eye camera.
10. Check that the eye's gaze is accurately represented by the X and Y values. To
do this:
a. Get your subject to look left. The X value decreases.
Tip
To see all the data, you may need to click the Scale the graph to
Tip
The X values should not go above 640 or below 0. The Y values
should not go above 480 or below 0.
• X (mm): -20
• Y (mm): -40
• Z (mm): -25
2. Change the view pane to 3D Perspective and look at the Head object.
The eyeball should be approximately where the eye is, relative to the Head
markers.
Vicon Tracker User Guide For use with Tracker 3.10 Page 89 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. Get the subject to look at the marker at the center of the T on the wand.
3. In the Calibration area of the Eye Tracker Properties pane, click Add.
The Samples box displays 1.
Tip
If an error is made during calibration, you can remove the last sample
you added by clicking the Remove button.
5. Repeat step 4.
The number of samples goes up to 3 and an eye with an eye vector coming
from it appears in the 3D Perspective view pane.
In the Calibration area of the Properties pane, a Residual value is displayed.
6. Get your subject to keep their head still and move the wand around,
following the marker at the center of the T with their eyes.
In the 3D Perspective view pane, the eye vector now follows the wand.
7. On the System tab, select the Eye Tracker. Change the view pane to Graph.
Ray X, Ray Y and Ray Z values are displayed, as well as X and Y values.
Vicon Tracker User Guide For use with Tracker 3.10 Page 90 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. Calibrating cameras During the first stage, the Tracker camera calibration
process calculates the physical position and orientation of each Vicon camera
in the capture volume based on the movement of the calibration object.
Tracker uses this information to determine each camera's physical position
and orientation in the capture volume and correct for any lens distortion.
2. Setting volume origin During the second stage, you set the volume origin in
Tracker. Tracker measures the position of the calibration object and uses this
information to identify the origin of the world and its horizontal and vertical
axes. These volume origin and axes are referred to as the global coordinate
system. The global axes coordinates are given in the form (x, y, z), where x is a
horizontal axis, y is the horizontal axis perpendicular to x, and z is the vertical
axis.
Vicon Tracker User Guide For use with Tracker 3.10 Page 91 of 205
21 March 2023, Revision 1
BEYOND MOTION
Section Description
Create Camera Masks Automatically create cameras masks to obscure all
reflections visible to the Vicon cameras. For more
information, see Creating camera masks
automatically on page 166 and Creating camera masks
manually on page 167.
Calibrate Cameras Calibrate the Vicon cameras to determine their
positions, orientations, and lens properties, which
enables Tracker to produce accurate 3D data from
motion data captured throughout the capture volume.
For more information, see Calibrate Vicon cameras on
page 93.
Set Volume Origin Define the global origin and the axes of the world (in
the context of the capture volume). For more
information, see Calibrate Vicon cameras on page 93.
Manage Camera Calibration Reset, load, or save camera calibration defining
settings for the Vicon cameras in your Tracker system.
For more information, see Calibrate Vicon cameras on
page 93.
Vicon Tracker User Guide For use with Tracker 3.10 Page 92 of 205
21 March 2023, Revision 1
BEYOND MOTION
The Vicon camera calibration process describes the capture volume to the
system, enabling Tracker to determine the positions, orientations, and lens
properties of all the Vicon cameras. Tracker uses this information to produce
accurate 3D data. During the camera calibration process, Vicon Tracker creates a
calibration parameters (.xcp) file. This file contains the calibration settings and
threshold data specified for the Vicon cameras in your Tracker system and is
used when data from these cameras is processed. An .x2d file containing the
latest calibration data, of the format LatestCalibration yyyymmddnnnnnn.x2d, is
also saved in the same location as the .x2d containing the recorded trial data.
Important
As part of the first stage of the daily Tracker motion capture workflow,
Vicon recommends that you calibrate your Vicon cameras each day
before you capture any data. This ensures that any unexpected changes
in your setup that may have occurred when the system was unsupervised
will not influence the quality of your data. You can perform the level of
camera calibration that suits your requirements: a full camera calibration
or a calibration refinement (for more information, see Understanding
calibration types on page 97).
• If you want to calibrate only some of the cameras, on the System tab in the
Resources pane, expand the Vicon Cameras node and select the Vicon
cameras that you want to calibrate;
or
2. On the Calibrate tab, expand the Calibrate Cameras section and from the
Wand drop-down list select the type of dynamic calibration object you are
using.
Vicon Tracker User Guide For use with Tracker 3.10 Page 93 of 205
21 March 2023, Revision 1
BEYOND MOTION
3. View or change the settings for the required parameters (if required, click
Show Advanced to reveal additional settings), ensuring that you select the
appropriate option from the Calibration Type list: Full Calibration or
Calibration Refinement.
Tip
If you have already performed a full calibration, Calibration
Refinement is selected by default, as this will normally be the most
appropriate option. (For more information, see Understanding
calibration types on page 97.)
5. In the capture volume, wave the calibration wand throughout the area where
you intend to capture 3D data, ensuring that the markers on the calibration
object are visible to the cameras. Vicon Tracker begins to capture wand wave
data.
6. In each Camera view pane, check the display of colored lines identifying wand
frames, ensuring that a good number of wand frames are spread across the
intended 3D capture volume.
Tip
If no cameras are visible in the Camera view pane, make sure they
are selected on the System tab in the Resources pane.
If any optical camera does not capture wand data during a wand
wave, select the relevant camera on the System tab, look in the
Settings section of the Properties pane, and ensure you have set the
Grayscale Mode to Auto.
7. On the Calibrate tab, in the Camera Calibration Feedback section, check the
Wand Count values returned for each Vicon camera.
(If you selected the Auto Stop option in the Parameters section, Tracker
automatically stops the calibration process when sufficient calibration
information has been acquired.)
Vicon Tracker User Guide For use with Tracker 3.10 Page 94 of 205
21 March 2023, Revision 1
BEYOND MOTION
9. In the Camera Calibration Feedback section, monitor the progress bar until
the camera calibration process is complete and review the Wand Count and
Image Error data. As a general guideline, Tracker typically takes 15-60
seconds to complete its calculations for a typical Vicon system setup. When
the Vicon camera calibration has successfully completed, it is automatically
saved to an .xcp file.
Tip
Because calibration feedback values are based on factors such as the
size of the capture volume and the camera lens type, it is not
possible to provide general guidelines on typical or acceptable
ranges. Therefore, to determine the optimal values for your Vicon
system, shortly after the system is installed establish a baseline
against which you can compare future daily calibration values.
Vicon Tracker User Guide For use with Tracker 3.10 Page 95 of 205
21 March 2023, Revision 1
BEYOND MOTION
Control Description
Wand Calibration object to be used during the camera calibration process.
Calibration The level of camera calibration to be performed when the camera
Type calibration process is started:
• Full Calibration A full camera calibration process enables the
Vicon system to determine each camera's physical position and
orientation in the capture volume and to correct for any lens
distortions, and to set internal camera parameters. You must
perform a full camera calibration when the system is first installed
and set up or if your camera setup has changed significantly.
• Calibration Refinement A camera calibration refinement process
enables you to correct a simple problem with a camera
calibration. The Vicon system recalculates the previous
calibration data based on the current location of the cameras.
You can refine an existing calibration only if the camera positions
have not changed significantly.
For more information about calibration types, see Understanding
calibration types on page 97 below.
Cameras To A list of cameras to be included in the camera calibration process.
Calibrate Cameras not included in this list are not calibrated. If this field is blank,
all cameras are calibrated. The selection of cameras is applied when you
click the Stop button in the Calibrate Cameras section.
Refinement With auto stop selected, the minimum coverage (in number of frames)
Frames required per camera in the final phase of refining a camera calibration.
Wand Ratio Tolerance of the distance between the markers on the wand (expressed
Tolerance as a ratio), to enable it to be labeled in 2D. Default is 0.2.
Wand Tolerance in alignment of wand markers (relating to the maximum angle
Straightness allowed between markers) to enable it to be labeled in 2D.
Tolerance
Auto Stop Whether or not Tracker is to automatically stop the camera calibration
process when sufficient data has been collected.
Vicon Tracker User Guide For use with Tracker 3.10 Page 96 of 205
21 March 2023, Revision 1
BEYOND MOTION
Calibration Refinement uses exactly the same process as full calibration, but
without the initialization phase. It provides a reliable way to refine existing
calibration data to produce a calibration that is as good as a full calibration of
the same system, but is much faster.
To save time while maintaining accuracy, you can perform both full and
refinement calibration on any selected camera(s), as well as on all cameras.
Note that the value specified for Refinement Frames affects the number of
frames used:
• By Auto Stop
Vicon Tracker User Guide For use with Tracker 3.10 Page 97 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Progress bar This bar displays a percentage indicating the progress of the overall
camera calibration process.
Camera This column contains the device ID for each Vicon camera being
calibrated.
Wand Count For each Vicon camera, this value identifies the number of frames it has
captured containing the calibration object. Initially, the entry for the
number of wand frames is displayed in red; the entry turns green when
Vicon Tracker has acquired enough wand data to calibrate that camera
(by default 1000 frames). Because Auto Stop is not selected by default,
the calibration process only stops when you click the Stop button. If
you have selected Auto Stop, the calibration process stops when the
Vicon camera with the lowest frame count reaches the number of
frames specified in the Refinement Frames field in the Calibrate
Cameras section.
World Error Displays the calibration error in millimeters. World error is calculated
per camera from the Image Error in pixels and the distance of the
camera to the center of the volume. Cameras further away, with the
same image error, display a larger world error.
Image Error This value (in RMS distance in camera pixels) indicates the accuracy of
the 3D reconstruction of the markers. This value represents the
difference between the 2D image of each marker on the camera
sensor and the 3D reconstructions of those markers projected back to
the camera's sensor. Acceptable values depend on factors such as
camera type. the size of the capture volume, and the camera lens type.
Vicon Tracker User Guide For use with Tracker 3.10 Page 98 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
Before starting the set volume origin process, remove from the capture
volume all markers and the sources of any unwanted reflections that
have not been accounted for by camera masks previously created. To
set the volume origin, you need a calibration object, which is supplied
with your Vicon system.
2. On the Calibrate tab, in the Wand drop-down list, ensure that the calibration
object that you used when you calibrated the cameras is selected.
Tip
Tracker determines the unit of length for calculating the volume
based on the length of the calibration wand. If you specify a wand
that is a different length from the one you used during the Vicon
camera calibration, the volume will have the wrong unit of length, so
Tracker will be unable to locate the L-frame calibration object.
3. In the Set Volume Origin section, from the L-Frame drop-down list, select the
type of static calibration object you are using to set the volume origin.
4. In the capture volume, place the calibration object flat on the floor in the
position and orientation that you would like to be the origin of the global
coordinate system.
Vicon Tracker User Guide For use with Tracker 3.10 Page 99 of 205
21 March 2023, Revision 1
BEYOND MOTION
7. Verify that the global coordinate system was set successfully by checking that
the system tracks the static calibration object.
If it does not, check the following:
• Was the correct dynamic calibration object selected from the Wand drop-
down list at the top of the tools pane?
If not, repeat this procedure from Step 2, ensuring that you select the
correct entry for the calibration wand you used for calibrating the Vicon
cameras.
• Was the correct static calibration object selected from the L-Frame drop-
down list at the top of the Calibrate tab?
If not, repeat this procedure from Step 3, ensuring that you select the
correct entry for the L-frame you are using.
After you have set the global coordinate system, you can display the volume axis
marker in the lower-left corner of the 3D Perspective view pane.
You turn the display on or off in the Options dialog box by selecting or
deselecting Volume Axis under General View Options.
From Tracker 3.2 and later, you can also ensure that your coordinate system is
accurately aligned with the floor of the capture volume by automatically
detecting the floor plane, using markers in the volume to define it. For more
information, see Refine the position of the floor plane on page 101.
From Tracker 3.7 and later, after you have set the volume origin (see Setting the
volume origin on page 99), to improve calibration stability and consistency over
time (particularly in large volumes), you can create a large custom calibration
object from markers permanently placed across the volume. You can then use
this object, coupled with using the Auto Scale option, for subsequent setting of
the system origin. For more information, see Improve volume scaling and set a
fixed origin on page 104.
Vicon Tracker User Guide For use with Tracker 3.10 Page 100 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
To ensure the highest levels of accuracy, particularly for applications
involving ground truth, we strongly advise that you use volume scaling
regardless of the size of your capture volume.
1. Scatter a quantity of the same size Vicon markers across the floor of your
capture volume. If you want Tracker to automatically recognize these markers
as floor plane markers, ensure that they outnumber any other groups of
markers (e.g, markers on a wand or markers that were used to focus cameras,
etc).
2. Complete the usual system calibration procedure to set the volume origin.
3. On the Calibrate tab, expand Set Volume Origin and display the Advanced
properties.
4. Next to Set Floor Plane, ensure that the options are as required:
Vicon Tracker User Guide For use with Tracker 3.10 Page 101 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. After you have completed the usual calibration and setting volume origin
procedures, load the calibration object that you used for calibration. To do
this, on the Objects tab, click the Load an Object button and locate the
relevant calibration object. The default location is:
C:\Users\Public\Documents\Vicon\Tracker3.x\Objects
• On the System tab, click the object and in the Properties pane ensure
Show Advanced is selected, then edit the Global Position fields and Global
Rotation fields as necessary; or
4. When you are happy with the position of the calibration object, right-click it
and click Save Object As. Enter a suitable name, and click Save.
5. Click the Calibrate tab, and in the Set Volume Origin section, select your
calibration object from the L-frame list.
Vicon Tracker User Guide For use with Tracker 3.10 Page 102 of 205
21 March 2023, Revision 1
BEYOND MOTION
During the Vicon camera calibration process, Vicon Tracker creates a calibration
parameters (.xcp) file. The changes in the .xcp file are automatically written to the
calibration file, which overwrites the current file. If you want to be able to load
the previous calibration in later, you must save it.
• On the Calibrate tab, go to the Manage Camera Calibration section and click
the required button:
Button Description
Auto Number Enables you to quickly number the currently connected Vicon
Cameras cameras in ascending order, according to their position in the
capture volume. To obtain useful autonumbering, you normally
auto-number the cameras at some point after you have aimed (and
calibrated) the cameras.
Automatic numbering starts with the camera that is furthest from the
volume origin. The cameras are then numbered in a clockwise
direction around the volume. If your cameras are positioned at
different levels, the cameras in the level that contains the most
cameras are numbered first.
Reset Removes all non-existing cameras, clears the calibrated position for
existing cameras, and reverts all calibration parameters to their
default settings. This enables you to recalibrate the system from a
clean starting point.
Load Displays the Choose a file dialog box, from which you can navigate
to and select the required .xcp file and click Open.
Save Saves the current calibration.
Vicon Tracker User Guide For use with Tracker 3.10 Page 103 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
If it is impractical to use permanently fixed markers in your volume, you
can still benefit from following this procedure, but when you come to
recalibrate, substitute a scaled wand object in place of the custom
calibration object. Your results will not be as accurate as they would with
the custom calibration object, but you will still benefit from the scaling
involved. For details, see Step 2 of Recalibrate with the scaled wand
and custom calibration object on page 112.
• Choose LEDs or markers for your custom calibration object on page 105
• Scale the Active Wand and the custom calibration object on page 106
• Recalibrate with the scaled wand and custom calibration object on page 112
Vicon Tracker User Guide For use with Tracker 3.10 Page 104 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Reflective markers
If you use reflective markers to create your custom calibration object,
remember that as passive markers are continually visible, you may need to
cover them while the volume is in use.
Vicon Tracker User Guide For use with Tracker 3.10 Page 105 of 205
21 March 2023, Revision 1
BEYOND MOTION
• For best performance, fix the LEDs or markers to the floor (provides both
stability and the ability to spread across the volume).
If this is not possible, position them on a wall or truss.
• For best scaling performance, position the custom calibration object across
the central two-thirds of the volume (to avoid variability introduced by
gaps in coverage at the volume edges). If this is unfeasible, try to make the
custom calibration object as large as possible, and position it towards the
center of the volume.
1. Calibrate using the normal process and standard .vsk files (see Calibrate
Vicon cameras on page 93).
2. Set the origin using a standard calibration object (see Setting the volume
origin on page 99).
3. In Tracker, create an object for the markers of the custom calibration object
(for details, see Creating an object on page 117).
Important
When you create the object:
• Do not save this object. It is important that the object that is used for
this scaling is created from the current marker observations.
• If you plan to use this object for setting the origin (see Working with
object properties on page 132), under the object's Advanced
properties, set the Global Position to (0,0,0).
Vicon Tracker User Guide For use with Tracker 3.10 Page 106 of 205
21 March 2023, Revision 1
BEYOND MOTION
4. On the Objects tab, ensure the custom calibration object is selected, right-
click and then click Use for Camera Calibration .
Vicon Tracker User Guide For use with Tracker 3.10 Page 107 of 205
21 March 2023, Revision 1
BEYOND MOTION
A line is added to the table containing the Model Distance, which is the
distance between the markers as measured by the current Vicon
calibration.
Vicon Tracker User Guide For use with Tracker 3.10 Page 108 of 205
21 March 2023, Revision 1
BEYOND MOTION
c. In the Measured Distance column, enter the distance that you measured in
millimeters.
d. For each set of measurements you have taken from the object, repeat
steps b and c.
In the New Settings section, the scale factor that will be applied is
displayed, together with the output names for the scaled wand and
calibration objects.
Vicon Tracker User Guide For use with Tracker 3.10 Page 109 of 205
21 March 2023, Revision 1
BEYOND MOTION
e. If you are happy with this measurement, click Save to exit the dialog box.
A scaled wand and a calibration object file are saved by default to C:
\Users\Public\Documents\Vicon\Tracker3.x\CalibrationObjects and are
displayed in the Wand and L-Frame lists on the Calibrate tab.
The current calibration is also scaled by the same factor, so you do not
need to recalibrate after this operation.
Vicon Tracker User Guide For use with Tracker 3.10 Page 110 of 205
21 March 2023, Revision 1
BEYOND MOTION
6. In future, to obtain an accurately scaled volume, use the new scaled wand and
calibration object when performing the calibration and set object operations
(see Recalibrate with the scaled wand and custom calibration object on page
112).
If you do not add measurements, the object is saved as a calibration object with
no scaling modification, and no scaled wand is saved. You can still use the new
calibration object for set origin operations, including auto-scale. This will provide
consistency of scale across set origin operations, but the volume will not be
scaled to external measurements.
Vicon Tracker User Guide For use with Tracker 3.10 Page 111 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. For the best results, set the origin using the normal process, but:
Vicon Tracker User Guide For use with Tracker 3.10 Page 112 of 205
21 March 2023, Revision 1
BEYOND MOTION
Tip
If you can't use permanently fixed markers in your volume, in Step 2
above, substitute the scaled wand object in place of the custom
calibration object. Your results will not be as accurate as they would
with the custom calibration object, but you will still benefit from the
scaling of the wand.
Vicon Tracker User Guide For use with Tracker 3.10 Page 113 of 205
21 March 2023, Revision 1
BEYOND MOTION
Prepare and manage the objects whose motion data you want to track in Vicon
Tracker on the Objects tab. Objects are a rigid, asymmetrical arrangement of at
least three markers. Multiple objects can be defined to track many rigid bodies
at the same time and different smoothing filtration presets can be applied to
each one.
Vicon Tracker User Guide For use with Tracker 3.10 Page 114 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Objects list Lets you enable an object for motion capture and data recording. If a
working .vsk file exists for the object, the object symbol is orange and
the object name is gray. If the name is red, the .vsk file is not suitable
for tracking (this may be due to symmetry in the arrangement of
markers, or similarity to another enabled object). To display a tool tip
identifying the problem, hover the mouse pointer over the object.
To display or hide the model markers defined in the .vsk file, expand
( + ) or collapse ( - ) the Markers list.
Tips To manage specific objects, in the Objects list, right-click on the
relevant node and from the context menu select a command. The
Open Folder option, at the bottom of the context menu, provides a
quick way to locate a relevant file. The color-coded symbols displayed
for entries in the Markers list correspond to the colors defined for each
model marker in the .vsk file.
Object Type Enables you to view and manage the type of smoothing applied to a
Preset section selected object. Smoothing is achieved using a One Euro, low-pass
smoothing filter. You can choose from one of the following supplied
filters:
• HMD: Used for head-mounted devices
• InteractionDevice: Used for legacy devices, such as Apex
• General: Used as a general purpose starting point
If none of the supplied filter types is suitable for your
application, you can also create and save your own custom
filter presets, so that you can quickly and accurately apply them
to other objects (for more information, see Creating an
object on page 117).
Vicon Tracker User Guide For use with Tracker 3.10 Page 115 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Add Marker to To add marker(s) to the selected trajectory of a selected object, click
Object controls the Add button.
If a calibrated object becomes distorted due to a marker having been
been lost and replaced in a slightly different position from its original
location, to update the marker position, select the affected marker and
click the Recalibrate button.
Vicon Tracker User Guide For use with Tracker 3.10 Page 116 of 205
21 March 2023, Revision 1
BEYOND MOTION
Creating an object
For motion capture and data streaming recording to take place, you must create
objects. Objects are a rigid, asymmetrical arrangement of at least three markers
whose motion data you want to track. Multiple objects can be defined to track
many rigid bodies at the same time. If necessary, you can apply different levels of
filtration to each object to obtain the required smoothing.
To create an object:
1. If you are streaming live, on the Objects tab in the Resources pane, click
Pause .
2. Ensure that in the Object Tracking Mode section at the bottom of the tab,
Track mode is not selected. This enables you to see unlabeled
reconstructions in the 3D Perspective view pane.
4. Select the (three or more) markers you want to include by doing one of the
following:
• To select markers individually, press and hold the CTRL key while you left-
click on each marker.
• To select a group of markers, press and hold the ALT key while you drag
around the markers to form a box around them.
5. With the markers selected, enter a name in the Create Object box and then
click Create.
Tip
In the Create Object text box, the name is automatically incremented
by 1 each time you click Create, so that, to create another object with
the default name of ObjectName_n, you can just select the required
markers and click Create.
Vicon Tracker User Guide For use with Tracker 3.10 Page 117 of 205
21 March 2023, Revision 1
BEYOND MOTION
b. Depending on whether you want to use an existing filtration type for this
object, do one of the following:
or
• If the required filtration type does not exist, in the Object Type
Preset section, click Manage Presets and in the Object Presets
dialog box, enter a name in the Create New Preset box and then
click Add.
c. In the Presets section, ensure the new preset is selected, then in the
Smoothing section, change the Translation and Rotation properties as
required.
d. With Translation Beta set to zero, change the value of Translation Min
Cut-Off to eliminate jitter during very slow movements.
Note that decreasing the value of Translation Min Cut-Off reduces jitter
but increases lag.
e. When you have finished adjusting the Translation Min Cut-Off value,
increase the value of Translation Beta by very small increments to
eliminate lag during faster movement.
Note that 0 = filtering on all translation motion; 1 = filtering on very slow
translation motion only.
f. Follow the same procedure for adjusting the Rotation Min Cut-Off and
Rotation Beta.
For detailed information on the One Euro filter and how to adjust these
settings, visit www.lifl.fr/~casiez/1euro/.15
g. If you want Tracker to detect the object as static, select the Motion Model
check box.
h. When you have finished adjusting the properties, click Close.
7. On the Objects tab, make sure that in the Object Type Preset section, the
required filter is displayed for the selected object.
15 http://www.lifl.fr/~casiez/1euro/
Vicon Tracker User Guide For use with Tracker 3.10 Page 118 of 205
21 March 2023, Revision 1
BEYOND MOTION
c. Drag the manipulator axes to orient the object to the desired pose.
9. Save the object by right-clicking it the Objects list and selecting Save Object
from the context menu.
Tracker saves the contents of the object in a .vsk file in the Objects folder.
Important
Viewing unlabeled reconstructions requires additional processing, so for
lowest output latency, when you have finished creating objects, ensure
Track mode is selected. When Track mode is selected, the Track button
is green.
Vicon Tracker User Guide For use with Tracker 3.10 Page 119 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. On the Objects tab tool bar, click the Load an Object button.
2. In the Choose an Object File dialog box, navigate to an existing .vsk file,
select it and then click Open.
Caution
If the selected .vsk file has the same name as an object currently
loaded in Tracker, the contents of the selected .vsk file replace those
in the currently loaded object.
Vicon Tracker User Guide For use with Tracker 3.10 Page 120 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. Click any axis. Three circles associated with the axes are displayed.
3. Click on a circle and rotate it until you see a gray rectangular shape snap into
place.
2. Click any axis and drag towards the marker until it snaps into place.
Vicon Tracker User Guide For use with Tracker 3.10 Page 121 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. In the view pane, select two markers by pressing CTRL while left-clicking each
marker.
A gray, projected marker is displayed at the midpoint between the two
markers.
2. Left-click on the desired axis and move it towards the gray projected marker
until it snaps into the midpoint.
Vicon Tracker User Guide For use with Tracker 3.10 Page 122 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. In the view pane, to select the marker that you want to add to the object, click
the marker.
Vicon Tracker User Guide For use with Tracker 3.10 Page 123 of 205
21 March 2023, Revision 1
BEYOND MOTION
Managing objects
After you have loaded an existing .vsk file or created a new object, you can save
or delete the object, or move its centroid as described in the following steps.
See also:
Tracker saves the contents of the object in a .vsk file in the Objects folder.
To delete an object:
1. On the Objects tab, right-click the object and select Delete Object from the
context menu.
• In the view pane, click an axis and move along that axis until you reach the
location you want. Repeat for the other axis until the required location is
reached.
Vicon Tracker User Guide For use with Tracker 3.10 Page 124 of 205
21 March 2023, Revision 1
BEYOND MOTION
The ability to act on multiple objects simultaneously is useful when you are
working with similar objects, such as the collection of rigid bodies that make up a
single subject.
You can group objects and then select the group, so that activation, selection,
and deletion applies to all objects in the selected group.
Vicon Tracker User Guide For use with Tracker 3.10 Page 125 of 205
21 March 2023, Revision 1
BEYOND MOTION
Create a group
To create a group of objects:
1. On the Objects tab, click to select the required objects, then right-click and
on the context menu click Group Objects.
3. To see the objects in a group, expand the group by clicking the arrow to the
right of the group name. By default, all objects in the group are activated:
On the Objects tab, right-click the name of the object that you want to add to
the group, point to Add to Group, and then click the name of the required
group.
Vicon Tracker User Guide For use with Tracker 3.10 Page 126 of 205
21 March 2023, Revision 1
BEYOND MOTION
• All objects in a group: Clear or select the check box to the left of the group
name.
• One or more objects within a group: Expand the group and clear or select the
check box to the left of the object name.
The check box to the left of the group name changes to reflect the activation
status of objects within the group.
When you select a group (that is, click its name on the Objects tab), all the
objects in the group are selected by default:
You can also click, SHIFT-click and CTRL-click to select/deselect one or more
objects within the group.
On the Objects tab, you can ungroup and/or delete grouped objects in either of
these ways:
• All objects in a group: Right-click the group name and click the required
option:
• Delete permanently deletes the group and all the objects within it.
• Ungroup moves all the group's objects outside the group and lists them
separately on the Objects tab. The group name is no longer displayed.
or
Vicon Tracker User Guide For use with Tracker 3.10 Page 127 of 205
21 March 2023, Revision 1
BEYOND MOTION
• One or more objects within a group: Expand the group, right-click the
required object(s) and then click the required option:
• Remove Object from GroupName moves the object from within the group
to outside the group, so that it is listed separately on the Objects tab.
On the Objects tab, expand the group, right-click the object and click Save
Object.
Vicon Tracker User Guide For use with Tracker 3.10 Page 128 of 205
21 March 2023, Revision 1
BEYOND MOTION
3. Ensure nothing is selected and then in the view pane, drag or rotate the
object axes to enable them to snap to the grid.
Tip
To change the distance between the lines of the grid to which
objects can snap, in the Options dialog box, select Floor Grid and
adjust as required.
Vicon Tracker User Guide For use with Tracker 3.10 Page 129 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. On the System tab, click the object and then in the Properties pane, click
Show Advanced.
2. In the view pane, drag or rotate the object's axes and observe the change in
the values in the Global Position fields (the location of the object within the
global coordinate system in millimeters) and Global Rotation fields (the
orientation of the object within the global coordinate system in degrees).
Tip
To set the current position of the object to the global position of 0, 0,
0 (that is, the origin), click the arrow to the right of the Global
Position fields and select Set to Default.
Vicon Tracker User Guide For use with Tracker 3.10 Page 130 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. On the Object tab, if necessary, expand the node of the object whose
markers you want to change.
3. In the Reorder Markers dialog box, click to select the marker whose position
you want to change and choose from the following options:
• Move Up
• Move Down
Vicon Tracker User Guide For use with Tracker 3.10 Page 131 of 205
21 March 2023, Revision 1
BEYOND MOTION
Setting Description
Name The name of the selected object. This name is used when the Vicon
Skeleton is saved in a .vsk file.
To change the name, do any of the following:
• In the Name box in the Properties pane, select the current
name and enter a new one; or
• Click the button next to the Name box to display the Name
dialog box, select the existing object name and enter a new
one; or
• On the Objects tab, double-click the current name and enter a
new one.
Vicon Tracker User Guide For use with Tracker 3.10 Page 132 of 205
21 March 2023, Revision 1
BEYOND MOTION
or
2. In the Properties pane, click the currently displayed color in the Color box.
3. In the Select Color dialog box, assign a color in the Basic colors area, or
define a new color in the Custom colors area and then click OK.
Vicon Tracker User Guide For use with Tracker 3.10 Page 133 of 205
21 March 2023, Revision 1
BEYOND MOTION
Save and play back recordings of trial data, using the controls on the Recording
tab.
Note
You will only see the Recording tab if you have the required license. For
more information, contact Vicon Support16.
16 mailto:[email protected]
Vicon Tracker User Guide For use with Tracker 3.10 Page 134 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Recording section In the Recording section, specify your requirements for
recording live trials. When you have finished specifying
your requirements, click the Start button to begin
recording.
Location Select Private or Shared, depending on your
requirements.
Open Folder View the location of the saved files. The default file
location depends on whether files are saved as Shared or
Private:
• File type: Private
File location (English language version): C:
\Users\UserName\AppData\Roaming\Vicon\Track
er3.x\CapturedTrials
• File type:Shared
File location (English language version): C:
\Users\Public\Documents\Vicon\Tracker3.x\Captu
redTrials
Note: For each trial recorded, at least three files are
saved: .x2d, .system, and .xcp files. In addition, whenever
a new calibration is performed, an additional .x2d file, of
the format LatestCalibration yyyymmddnnnnnn.x2d,
containing the latest calibration data, is saved in the same
location as the .x2d containing the recorded trial data.
(This can be useful for data analysis and troubleshooting.)
If you are using an analog device to capture data, an .x1d
file is also saved.
Trial Name Enter a name for the new trial.
Auto Increment When selected, the trial number is automatically
Trial Number appended to the file name.
Permit When selected, existing captured trial data in the same
Overwrite of folder (see above) is overwritten when the new file is
Existing Files saved.
Show/Hide Displays or hides additional controls, such as those for
Parameters remote triggering.
Start/Stop on When selected, a remote trigger can be used to control
Remote Trigger capturing start and stop times. The remote device must
be connected to your Vicon system.
Vicon Tracker User Guide For use with Tracker 3.10 Page 135 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Capture Before To capture data before the capture start is triggered
Start (secs) either manually (by clicking Start) or automatically (based
on a remote trigger), select this check box and enter the
required number of seconds.
Stop after To end the trial automatically after a specified number of
Duration (secs) seconds, select this check box and enter the required
number of seconds.
Start/Stop over To make a UDP broadcast to a third-party application
Network that capture has started or stopped, select this check box
and from the adjacent drop-down list, select Send or
Receive. In the Address list, either select the IP address of
the network card that will be used to send or receive the
start/stop trigger message, or select All. In the adjacent
field, specify the UDP port which is to send or receive the
message.
Arm button To set the system to a state where it is ready to accept a
trigger for automatic capture based on a signal broadcast
over the network from a remote device, click this button.
If you want to enable the system to remain ready to
receive subsequent network signals after the capture is
stopped, click the Lock button to the right of the Arm
button.
Playback In the Playback section, click the Load Trial button to select the trial you
section want to play back.
Export CSV In the Export CSV section, select options to save trial data to a CSV file. For
section more information, see CSV Export, in What's New in Vicon Tracker.
Tip
Before attempting to load a trial, in the Recording section, ensure that the
relevant Location setting is selected (Shared or Private), depending the
option chosen for the trial you want to load.
Vicon Tracker User Guide For use with Tracker 3.10 Page 136 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. Ensure your system is connected and calibrated and that Tracker is in Live
mode.
3. In the Location area, select whether your trial will be saved as Shared or
Private files.
4. In the Trial Name box, enter a name for the new trial. If you want a number to
be automatically appended to the file name, ensure Auto Increment Trial
Number is selected.
5. If you want existing captured trial data in the same folder to be overwritten
when a new trial is saved, select the Permit Overwrite of Existing Files box.
• If your trial requires any further setup, for example, if you are using remote
triggering, click Show Parameters and supply the necessary information:
Vicon Tracker User Guide For use with Tracker 3.10 Page 137 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 138 of 205
21 March 2023, Revision 1
BEYOND MOTION
Example notifications
The XML file contains the following notifications:
Vicon Tracker User Guide For use with Tracker 3.10 Page 139 of 205
21 March 2023, Revision 1
BEYOND MOTION
Start notification
The following example shows a Start notification. Note that the broadcast must
fit into one UDP packet.
The indents in the following example are for clarity: the actual packet is not
indented. White space between tokens is removed.
Where:
Name The name of the trial, which is used as the filename for the capture
files, for example <Name>.x2d.
Notes Any notes provided
Description Any description provided. Avoid very long description strings as
the broadcast must fit into one UDP packet. If it does not, the
broadcast is not sent.
DatabasePath The target path for the capture files.
Delay The number of milliseconds that the broadcast is made before the
capture starts. This delay enables clients to do any preparation
required to respond.
PacketID A number that individually identifies the packet. It is incremented
for each packet generated. Use it to discard duplicate packets that
are delivered by UDP. (This can happen if there are multiple paths
between the broadcasting and listening machines.)
Vicon Tracker User Guide For use with Tracker 3.10 Page 140 of 205
21 March 2023, Revision 1
BEYOND MOTION
Stop notification
The following example shows a Stop notification. It is a notification that
capturing has stopped.
Note that writing the file to disk may not be complete. Wait for the
corresponding Complete notification before trying to open the file.
• FAIL - Everything was not ok. Perhaps the disk ran out of room, or the system
was unplugged. You may get a truncated file.
• CANCEL - The user stopped the capture process. There will not be a
Complete notification.
Vicon Tracker User Guide For use with Tracker 3.10 Page 141 of 205
21 March 2023, Revision 1
BEYOND MOTION
Complete notification
The following example shows a Complete notification. It indicates that the
captured file is ready at the path specified. Note that:
• If the file is on a remote drive, it may be captured locally and then copied to
the final location. This may take some time.
Vicon Tracker User Guide For use with Tracker 3.10 Page 142 of 205
21 March 2023, Revision 1
BEYOND MOTION
Where:
• Hours
• Minutes
• Seconds
• Frames
• Field
• 0 - Even Field
• 1 - Odd Field
• Standard
• 0 - PAL
• 1 - NTSC
• 2 - NTSC Drop
Vicon Tracker User Guide For use with Tracker 3.10 Page 143 of 205
21 March 2023, Revision 1
BEYOND MOTION
• 3 - Film at 24fps
• 4 - NTSC Film
• 5 - 30Hz exactly
• Sub-Frames Per Frame (the multiple of the timecode rate that the system is
running at)
Vicon Tracker User Guide For use with Tracker 3.10 Page 144 of 205
21 March 2023, Revision 1
BEYOND MOTION
The values for TimeCode are as listed in Timecode start notification on page 143.
Vicon Tracker User Guide For use with Tracker 3.10 Page 145 of 205
21 March 2023, Revision 1
BEYOND MOTION
Where:
The frames per second of the system can be calculated as TICKS/PERIOD. This
representation of the frame rate avoids rounding errors for rates such as NTSC,
which cannot be stored in a double without a loss of precision.
Vicon Tracker User Guide For use with Tracker 3.10 Page 146 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. On the Recording tab, in the Recording area ensure that the relevant
Location setting is selected (Shared or Private), depending on the option
chosen for the trial you want to load.
2. In the Playback area, click Load Trial to access the location of the last saved
trial. If you want to load a different trial, browse to the appropriate location.
Click Open.
The recorded trial is loaded, a time bar appears beneath the view pane and
Tracker automatically enters Offline mode (if this was not already selected).
3. To play the recorded trial, click the Play button on the time bar. To stop or
pause the replay, click Stop or press the space bar on the keyboard. To view a
particular part of the trial, drag the slider along the time bar, or to move
through the trial, press the forward or back arrow keys.
To select from further options for examining the recorded data, click the
More option beneath the Play button on the time bar.
• Zoom to Trial – After zooming in to a selected range, resets the time bar
scale to include the whole trial
• Zoom to Region-of-Interest – After zooming out, resets the time bar scale
to zoom in to the selected range
Tip
To select a region of interest, drag the beginning and end markers
(small green triangles) to the start and end of the required range
on the time bar. To return the markers to their original positions at
the start and end of the trial, double-click them.
• Replay Speed – Enables you to select from preset options (in multiples of
real time) or to specify your own custom speed
Vicon Tracker User Guide For use with Tracker 3.10 Page 147 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 148 of 205
21 March 2023, Revision 1
BEYOND MOTION
The default position of the Communications pane is at the bottom of the Tracker
window. You can resize this pane, detach it from its current location, and move it
to another location within the Tracker window.
Information Description
type
Time The timestamp for the operation being executed in the hh:mm:ss
format.
Category The general Tracker function being performed, for example
Calibration Manager.
Text The specific action and its success or failure.
Vicon Tracker User Guide For use with Tracker 3.10 Page 149 of 205
21 March 2023, Revision 1
BEYOND MOTION
You can monitor the activity of your Vicon system in the Communications pane.
Its default position is at the bottom of the Tracker window.
A new log is written each time you start Tracker. New entries recorded during
the current session are appended at the bottom of the log. You can copy all or
part of the information in the log and save it to an external file, such as a Rich
Text Format (.rtf) or plain text (.txt) file.
1. In the Communications pane, view the entries for system activity and
processing operations.
2. Use the scroll bar to move down or back up the displayed entries.
2. Right-click and in the context menu click Copy. Tracker copies the text to the
clipboard.
3. Open a text editor, such as Microsoft Notepad, and paste the copied text.
Vicon Tracker User Guide For use with Tracker 3.10 Page 150 of 205
21 March 2023, Revision 1
BEYOND MOTION
You can also change scrolling behavior and delete and restore entries:
Vicon Tracker User Guide For use with Tracker 3.10 Page 151 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 152 of 205
21 March 2023, Revision 1
BEYOND MOTION
The view pane enables you to view the data of one or more cameras. In the view
pane, you view the objects selected in the Resources pane during any stage of
the Tracker workflow. Depending on the type of view pane selected, there are
additional lists and buttons available to you to manage the display options for
that type of view pane.
By default, the view pane is above the Communication pane and to the right of
the Resources pane. You cannot detach or change the position of this pane, but
you can resize it. In addition, you can open a new floating workspace that can be
displayed on a second monitor, if required.
Component Description
Configuration Enables you manage the configurations that you create in the view
management pane. Saved configurations include the layout of view panes as well as
controls any cameras, hardware devices, and object components selected in
the Resources pane, on the System tab, the Calibration tab, the
Objects tab, and/or the Recording tab when the configuration was
created.
Vicon Tracker User Guide For use with Tracker 3.10 Page 153 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
View pane list The view pane list allows you to configure the way in which you view
Tracker data. Select from the following types of view panes:
3D Perspective
Reconstructed motion capture data from all active Vicon cameras in
3D.
3D Orthogonal
Motion capture data in 3D viewed from a specified point of sight or
direction of the capture volume.
Vicon Tracker User Guide For use with Tracker 3.10 Page 154 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Camera
Raw 2D motion capture data from an individual Vicon camera.
Graph
Various values of one or more selected items, such as the x, y, and z
components of a marker trajectory, plotted against each other or
against time.
Vicon Tracker User Guide For use with Tracker 3.10 Page 155 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Split view Split the current view horizontally into two view
buttons Horizontal
panes.
Split the current view vertically into two view panes.
Vertical
Close the current view pane. You cannot close the
Close
default view pane in the center of the Tracker
window.
View pane time Enables you to play back recorded trials. Click More or right-click the
bar time bar to access further options for examining recorded trial data:
To select a region of interest, drag the beginning and end markers (small green
triangles) to the start and end of the required range.
To return the markers to their original positions at the start and end of the trial,
double-click them.
Vicon Tracker User Guide For use with Tracker 3.10 Page 156 of 205
21 March 2023, Revision 1
BEYOND MOTION
You view the reconstructed motion data from all active Vicon cameras in 3D.
Component Description
3D Perspective You manage the display of 3D data in the active workspace by
view pane tool
bar selecting the following button: Center camera on selection
Positions the currently selected data in the center of the view pane.
This option does not automatically zoom in on the selected data.
When selecting an object to "follow", the camera also rotates with the
object.
3D Perspective You view and manipulate 3D data in the workspace. For example, the
view pane view can be oriented using the mouse and/or keyboard (see Mouse
workspace and keyboard shortcuts on page 21), such that you can focus on items of
interest.
Vicon Tracker User Guide For use with Tracker 3.10 Page 157 of 205
21 March 2023, Revision 1
BEYOND MOTION
Tip
To select multiple objects, hold down the ALT key and drag around
the objects you want to select.
To detach a marker, in the 3D Perspective view pane, right-click the
marker and in the context menu, click Detach Marker.
2. From the view pane tool bar, select 3D Perspective. The reconstructed 3D
data from all cameras is displayed in a single 3D Perspective view pane.
• On the Objects tab, examine the reconstruction and labeling and edit any
errors or inconsistencies; or
Vicon Tracker User Guide For use with Tracker 3.10 Page 158 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
3D Orthogonal Manage the display of data in the active workspace with the
view pane tool bar following controls in the 3D Orthogonal view tool bar:
• Orthogonal view list
Set the point of sight by selecting one of the following
orthogonal projections (also called orthographic
projections):
• -Z (default)
• +Z
• +X
• -X
• +Y
• -Y
Vicon Tracker User Guide For use with Tracker 3.10 Page 159 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. From the view pane tool bar, select 3D Orthogonal. The reconstructed 3D
data from all cameras is displayed in a single 3D Orthogonal view pane,
initially from the Top view.
3. From the View list in the 3D Orthogonal view pane tool bar, either leave the
default or select another orthogonal projection to set the view to a different
point of sight:
• -Z (default)
• +Z
• +X
• -X
• +Y
• -Y
Vicon Tracker User Guide For use with Tracker 3.10 Page 160 of 205
21 March 2023, Revision 1
BEYOND MOTION
• On the Objects tab, check the reconstruction and labeling and edit any
errors or inconsistencies; or
Tip
You can select the Detach Marker command from the context
menu displayed when you right-click on a marker in the 3D
Perspective view pane.
Vicon Tracker User Guide For use with Tracker 3.10 Page 161 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
View Manage the way camera data is viewed in the active Camera view pane
by selecting the following options on the View drop-down list:
Vicon Tracker User Guide For use with Tracker 3.10 Page 162 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Rotated Rotate the camera view, so it is corrected to the
vertical axis defined in the system calibration (which
corresponds to the earth's vertical axis). It also
enables you to manually rotate the view by dragging
the view left or right. Information from the camera
calibration is required to present the rotated view.
Combined Correctly model lens distortions and display a
corrected camera view with the 3D workspace
rendered underneath the camera view.
Zoom to Fit Zoom the selected Camera view pane to fit the full
workspace.
Zoom to Zoom to the displayed sensor window. For more
Window information, see New sensor windowing display, in
What's New in Vicon Tracker.
Masks You can create a mask to hide any unwanted reflections and light
sources visible to a Vicon camera (such as stray reflections from other
objects or surfaces in the capture volume, opposing strobe units, and
direct light sources) with the following buttons in the Camera view pane
tool bar:
Paint a mask Paint over any cells in the camera grid (displayed
onto the camera when the button is clicked) that contain unwanted
reflections. When a cell is painted, its background
color changes from black to blue. The camera mask
consists of all blue cells obscuring unwanted
reflections.
Erase a mask Erase a previously painted cell from a mask. When an
from the individual cell is erased, its background color changes
from blue to black, and any reflection that had
camera
previously been obscured is visible again.
Clear the mask Automatically remove a previously painted mask.
from the When the mask is cleared, the background color of
any previously painted cells changes from blue to
camera black, and any reflections that had previously been
obscured are visible again.
Toggle display Display When selected, grayscale blobs are displayed in the
of centroids/ grayscale blobs Camera view.
grayscale blobs
Vicon Tracker User Guide For use with Tracker 3.10 Page 163 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Lock / Unlock Lock the current Camera view pane, so that it is effectively detached
Selection Set from the selection set and is not affected by any subsequent selections
in other open view panes. This is useful for displaying views from
different cameras in multiple Camera view panes.
Camera You view and manipulate 2D data in the workspace. You can manage
workspace the visualization of camera data, for example, you can orbit, truck, dolly,
and zoom the displayed data.
Vicon Tracker User Guide For use with Tracker 3.10 Page 164 of 205
21 March 2023, Revision 1
BEYOND MOTION
2. On the System tab in the Resources pane, select one or more cameras.
3. Expand the Vicon Cameras node and then click on the sub-node for one or
more specific Vicon cameras.
The 2D data from each camera selected on the System tab is displayed in a
separate Camera view.
Tip
To help you to determine the most effect threshold setting for
grayscale blobs, you can set the background color of the Camera
view to the value of the Threshold control in the Centroid Fitting
section of the Properties pane.
To do this, open the Options dialog box (F7), and in the General View
Options, select Threshold.
Vicon Tracker User Guide For use with Tracker 3.10 Page 165 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
Before using the automatic mask creation tool, ensure that you remove
from the capture volume any unnecessary objects, such as calibration
objects. For best results, the capture volume should be entirely free
from objects likely to cause background interference.
1. Press F7 to open the Options dialog box and under General View Options,
ensure that Threshold Map is selected.
Any reflections are visible in the Camera view pane, typically as non-circular
areas of grayscale or edge data. Note that reflections can severely affect the
camera data rates, and you may find that the camera overloads. In this case,
the camera automatically sends edge data instead of full grayscale data.
2. On the Calibrate tab, in the Create Camera Masks section, click Start.
All Vicon cameras are selected and a separate Camera view pane is displayed
for each one. The Start button changes to display Stop. Tracker starts
recording the data visible to each of the Vicon cameras connected. Any
camera masks that are created are displayed as blue cells in the Camera view
panes for the affected cameras. If there is no data visible to a particular
camera, Tracker does not create any masks for it. About 30 seconds of
recording is generally sufficient to enable Tracker to collect the data visible to
the cameras.
3. Click Stop.
Vicon Tracker User Guide For use with Tracker 3.10 Page 166 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
Before manually creating any masks, ensure that you remove from the
capture volume any unnecessary objects, such as calibration objects. For
best results, the capture volume should be entirely free from objects
likely to cause background interference.
1. On the System tab in the Resources pane, select all Vicon cameras.
2. On the view pane tool bar, select Camera to display the 2D data being
captured by each selected Vicon camera in a separate Camera view pane.
3. From the View drop-down list in the Camera view pane tool bar, make sure
that the 3D Overlay and Combined options are cleared.
4. Press F7 to open the Options dialog box and under General View Options,
make sure that Threshold Map is selected.
Tip
The Threshold Map default color is blue, but you can change the
color in the Options dialog box.
Any reflections are visible in the Camera view pane, typically as non-circular
areas of grayscale or edge data. Note that reflections can severely affect the
camera data rates, and you may find that the camera overloads. In this case,
the camera automatically sends edge data instead of full grayscale data.
Vicon Tracker User Guide For use with Tracker 3.10 Page 167 of 205
21 March 2023, Revision 1
BEYOND MOTION
6. From the Camera view pane tool bar, use the following buttons to hide any
unwanted reflections that are visible from the selected camera. (When you
click any of these buttons, a grid of small blue tiles is superimposed over the
camera image in each Camera view pane.)
Button Usage
Paint a mask Click an individual tile, click and drag across multiple consecutive
onto the tiles, or hold down ALT and click while dragging the mouse across
an entire area of unwanted reflections visible in the camera grid.
camera
You can drag the mouse horizontally, vertically, or diagonally. When
a cell is painted, its background color changes from black to blue.
The camera mask consists of all blue cells obscuring unwanted
reflections.
Erase a mask Click an individual tile, drag the mouse across multiple tiles, or hold
from the down ALT and click while dragging the mouse across an entire area
of blue cells in the camera grid. You can drag the mouse
camera
horizontally, vertically, or diagonally.
When an individual cell is erased, its background color changes
from blue to black, and any reflection that had previously been
obscured is visible again.
Clear the mask Click the button to automatically remove the entire mask from the
from the camera.
When the mask is cleared, the background color of any previously
camera painted cells changes from blue to black, and any reflections that
had previously been obscured are visible again.
Tip
To zoom in on the view pane, right-click and drag the mouse pointer
forward (to zoom in) or backward (to zoom out). To pan the image,
click both mouse buttons and drag. The camera masks are applied in
real time and are saved along with your camera calibration.
Vicon Tracker User Guide For use with Tracker 3.10 Page 168 of 205
21 March 2023, Revision 1
BEYOND MOTION
Save a configuration
To save a configuration:
Vicon Tracker User Guide For use with Tracker 3.10 Page 169 of 205
21 March 2023, Revision 1
BEYOND MOTION
You view and manipulate various values of one or more selected items (such as
the x, y, and z components of a marker trajectory) against time.
Component Description
Graph view pane You manage the display of graph data in the workspace with the
tool bar following controls and buttons on the Graph view pane tool bar at the
top of the view pane. The Graph view pane tool bar is designed to
lead you left to right through the normal flow of operations required to
plot a graph for the selected elements.
Graph type You select the type of graph to be displayed in the workspace from
under the categories in this drop-down list (graph types that are not
available for the current selection are dimmed):
Vicon Tracker User Guide For use with Tracker 3.10 Page 170 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Trajectories
• Components – The X, Y, and Z position of a
trajectory over time.
• Distance From Origin – The linear distance
between a trajectory and the origin.
• Distance Between – The distance between
two selected trajectories.
• Distance Between (xyz) – The absolute
distance (as a vector) between two selected
trajectories.
• Angle Between – The angle between three
selected trajectories.
• Trajectory Count – The number of
trajectories being reconstructed.
Metrics
• Latency – A measure of the time taken by
Tracker to perform some task. As data is
received from the hardware and is
processed, Tracker takes timestamps that are
used to calculate the latency estimate. If you
are using Firmware 222 or later, two different
kinds of latency are graphed.
• Data Delivered – The amount of time taken
between the sync packet being received and
the data for that frame being delivered from
the hardware. This is the integration period
of the camera – the time that it takes the
camera to process the sample and any
Ethernet overheads.
• Data Processed – The amount of time
between the sync packet being received and
the completion of data processing.
Vicon Tracker User Guide For use with Tracker 3.10 Page 171 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Differentiate the You specify for the displayed graph the current variable, its first
derivative (velocity or angular velocity), or its second derivative
Graph
(acceleration or angular acceleration) by selecting the desired options
from this drop-down list:
• x (none)
• x' (velocity)
• x" (acceleration)
A graph of a trajectory will have X, Y, and Z axes, but when
differentiated to x' (velocity) will change to X', Y', and Z' axes.
Graph You specify the components of the selected graph type to be plotted
Components in the active Graph view pane by selecting the required options from
this drop-down list (only components that you have selected for graph
view are available):
• Components - Dependent on the type of graph you have
chosen. For example, the count for the Trajectory Count graph.
• Select None
• Select All
This option enables you to focus on a component of particular
interest, which occupies more of the workspace. When multiple
components are plotted, each is always shown on a separate
axis, and the components shown are applied to all channels
visible in the workspace. The number of vertically stacked
graphs displayed in the workspace depends on the type of
graph selected and the number of components selected from
this component list.
Rotation Order If you select an object on the Object tab in the Resources pane, you
can select Global Angle from the Graph view tool bar. This enables the
Rotation Order button. Clicking on the Rotation Order button lists the
angle convention choices of Helical (default), XYZ, XZY, etc. This
enables you to choose either a Helical or an Euler angle convention.
The Euler angle convention itself has multiple rotation order
conventions represented by XYZ, XZY, etc.
Show Legend This button allows you to show a legend to the right of the graph trace
for each component being plotted.
Scaling You manage the scale of the graph (to ensure that the desired portions
of the selected traces are visible) with these buttons:
Fit Horizontally Zoom out the x-axis to show the complete range of
the trace for 100 frames. This is useful if you have
zoomed in a long way and now want to quickly see
the entire graph again.
Vicon Tracker User Guide For use with Tracker 3.10 Page 172 of 205
21 March 2023, Revision 1
BEYOND MOTION
Component Description
Lock Horizontal Lock the horizontal graph axis so that the current
zoom level is maintained.
Axis
Fit Vertically Scale the y-axis so that all the data in selected traces
for the currently visible x-axis is visible. If there are
multiple traces in the selected components, they are
all set to the same range required to show all the
data for all traces.
Lock Vertical Lock the vertical graph axis so that the current zoom
level is maintained.
Axis
Fit Both Scale the x and y axes simultaneously to fit the
Horizontally & horizontal and vertical ranges of data.
Vertically
Lock/Unlock Lock the current Graph view pane, so that it is effectively detached
Selection Set from the selection set and is not affected by any subsequent selections
in other open view panes. This is useful for displaying different
elements in multiple Graph view panes.
Graph view pane You view and manipulate graph data in the workspace.
workspace The workspace contains rulers and axes along the right and bottom
edges and graph traces for the item being plotted.
The y-axis vertical ruler is on the right side of the graph and the x-axis
horizontal ruler is below the graph. The y-axis represents the selected
component. The x-axis represents the time (in frames). It starts on the
right side, which is labeled 0 (current frame) and is labeled from right
to left with decreasing negative values to reflect the number of frames
away from the live frame.
Tips:
• To change the default number of samples to display when a
new real-time graph is opened, press F7 to open the Options
dialog box, click Graph on the left, and on the right side,
change the Default X-axis length value.
• When zooming into or out of graph data, the display of grid
lines in the workspace can be set to guide the eye toward the
selected area of focus. Major grid lines remain at their normal
weight, while any minor grid lines gradually fade. To obtain this
behavior, press F7 to open the Options dialog box, ensure
Graph is selected and in the Properties area, select Show
Minor Grid Lines.
Vicon Tracker User Guide For use with Tracker 3.10 Page 173 of 205
21 March 2023, Revision 1
BEYOND MOTION
The Graph view pane displays graphs for the types of data that can be produced
in a motion capture trial.
2. Select the markers to be graphed in either of the following ways. (The number
of markers you select depends on the type of graph you want to view, as
described in step 3 below.)
• On the Objects tab in the Resources pane, expand the required Object
node, expand the Markers node, and then select one or more markers; or
3. From the view pane tool bar, select Graph. A single Graph view pane is
displayed with the default Components graph type plotting the X, Y, and Z
components of each selected marker.
Tip
When you have displayed a Graph view pane, you can select
additional markers to add to the Graph view pane. Each trajectory is
displayed in a different color trace. To identify the color trace used
for each trajectory, click the Show Legend button (or hover the
mouse pointer over it) in the Graph view pane tool bar. If the trace
for any additional markers is not visible, use the Fit Horizontally, Fit
Vertically, or Fit Both Horizontally and Vertically buttons.
Vicon Tracker User Guide For use with Tracker 3.10 Page 174 of 205
21 March 2023, Revision 1
BEYOND MOTION
4. From the Graph Type list in the Graph view pane tool bar, select another
option under the Trajectories section to plot the selected marker trajectories
in a different type of graph:
• Distance From Origin: Plots the distance from the capture volume origin to
each selected marker. This is useful for later plotting velocity or
acceleration of markers.
• Angle Between: Plots the angle between the two vectors formed by three
selected markers. This is useful for seeing how the group of markers move
over time.
• Trajectory Count: Plots the total number of trajectories over time visible to
the Vicon cameras (if streaming Live data in real time) or processed in trial
(if viewing previously captured data in a file).
5. If you want to save a particular graph view (for example, specific trajectories
that you have selected), save your configuration using the view pane
configuration management controls.
Vicon Tracker User Guide For use with Tracker 3.10 Page 175 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 176 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 177 of 205
21 March 2023, Revision 1
BEYOND MOTION
Firmware notifications
When you start Tracker or connect any Vicon devices into your system, Vicon
Firmware Manager checks whether the firmware for all your devices is up-to-
date.
If your devices aren’t using the latest firmware, a warning triangle is
displayed on the right of the menu bar to let you know that a more up-to-date
version of the firmware is available.
Vicon Tracker User Guide For use with Tracker 3.10 Page 178 of 205
21 March 2023, Revision 1
BEYOND MOTION
To control the way data is visualized in the view panes, you use the controls in
the Options dialog box.
You access this dialog box from the Window menu or by pressing F7. You can
save the settings that you make in this dialog box, which enables you to
customize sets of options to use for different types of motion capture projects.
1. Press F7 or from the Window menu, select Options. The Options dialog box
is displayed.
2. In the Options list on the left, select or clear the relevant check box(es),
depending on the functionality you require.
3. To view or change the settings for an option, click on the option to select it.
The properties for that option are displayed in the Properties section.
Tip
To see any available additional settings, click Show Advanced. To
show basic settings only, click Hide Advanced.
4. In the Properties section, change the settings for the properties, as needed.
Vicon Tracker User Guide For use with Tracker 3.10 Page 179 of 205
21 March 2023, Revision 1
BEYOND MOTION
5. To save the changes you have made in the Options dialog box, in the
configuration management area, click the save button:
Tip
To indicate that you have made changes to a configuration but the
changes have not yet been saved, an asterisk * is displayed after the
configuration name in the configuration management list.
Vicon Tracker User Guide For use with Tracker 3.10 Page 180 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Use Tracker's built-in VRPN server to extend your usage of Tracker (see
Working with VRPN on page 182).
• Use the Vicon Control app, to set up, calibrate, and capture with a Vicon
Valkyrie or Vantage system (see Using the Vicon Control app with Tracker on
page 186).
• Use the Vicon DataStream SDK (or UDP) to access Vicon Tracker data from
Simulink (see Accessing Vicon Tracker data from Simulink on page 189).
Vicon Tracker User Guide For use with Tracker 3.10 Page 181 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 182 of 205
21 March 2023, Revision 1
BEYOND MOTION
Note
Head@TrackerPC is the way Virtools connects to the VRPN server within
Tracker. The format is object_name@PC_Name. This configuration file
will look for an object called "Head" on the Tracker server called
"TrackerPC."
=======================================
vrpnTracker_0 Head@TrackerPC
neutralPosition_0 0.0 0.0 0.0
neutralQuaternion_0 0.0 0.0 0.0 1.0
axisPermute_0 0 2 1
axisSign_0 1 1 1
trackerScale_0 1
TrackerGroup_0 T0:0:6
=======================================
Vicon Tracker User Guide For use with Tracker 3.10 Page 183 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Add the VRPN settings to a VRPack.cfg file, which is in the same folder as
the .cmo. That way it can be tested with Virtools Dev.
• For versions of Tracker before 1.2 in the composition, activate the Use Scale
option and change the value of trackerScale_0 in your VRDevice.cfg file to
0.001 (converts Vicon mm to Virtools m).
For a full description of any of these configuration options, please refer to the
Virtools documentation.
For sample files that use VRPN to connect Virtools to a tracked object within
Vicon Tracker, please contact Vicon Support on page 205 or download from
the Vicon website17.
17 https://www.vicon.com/downloads
Vicon Tracker User Guide For use with Tracker 3.10 Page 184 of 205
21 March 2023, Revision 1
BEYOND MOTION
To enable you to do this, Tracker provides a second set of VRPN trackers, which
are output with the existing ones. For easy identification, the names of this
second set of VRPN trackers are suffixed with _2.
1. On the System tab, select Local Vicon System and in the Properties pane
ensure Show Advanced has been selected.
Vicon Tracker User Guide For use with Tracker 3.10 Page 185 of 205
21 March 2023, Revision 1
BEYOND MOTION
Before you can use your iOS device with Tracker, you must pair it with the PC
that is running Tracker (the Vicon host PC).
1. Ensure that your iOS device is connected to a Wifi access point that is on the
same subnet as the Vicon host PC.
2. On the Vicon host PC, ensure that the required connection is used, that
Tracker is running, and the system is connected.
Vicon Tracker User Guide For use with Tracker 3.10 Page 186 of 205
21 March 2023, Revision 1
BEYOND MOTION
5. To use the same connection in future, select Remember this choice for future
connection attempts. To permit Control to access Tracker, click Allow.
Tip
If later you need to revoke authorizations for Vicon Control, on the
Window menu in Tracker, click Reset Control Authorization. This
revokes all stored authorizations.
6. To select a camera and display a camera view, tap at the bottom of the
screen.
You can swipe the camera view right or left to change to the next or previous
camera and use stretch and pinch as normal to zoom in and out.
Vicon Tracker User Guide For use with Tracker 3.10 Page 187 of 205
21 March 2023, Revision 1
BEYOND MOTION
To access the dial control, tap and hold in a selected camera view.
Use the dial to view and change settings, calibrate and capture.
Vicon Tracker User Guide For use with Tracker 3.10 Page 188 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
The UDP stream contains only a small subset of the data that is available
via the Vicon DataStream SDK, so if possible, use the Vicon DataStream
SDK in preference to the UDP stream.
To help you access Tracker data from Simulink, examples of both types of access
are installed with Tracker. They can be found in the following default location:
C:\Program Files\Vicon\Tracker3.#\Simulink
• About the Simulink examples provided with Vicon Tracker on page 195
Vicon Tracker User Guide For use with Tracker 3.10 Page 189 of 205
21 March 2023, Revision 1
BEYOND MOTION
Tip
You can use configurations other than compiled S-functions (such as
using MATLAB code within the Simulink block) but there may be a
performance disadvantage to using interpreted code. Alternative
configurations have not been investigated or tested by Vicon.
• A properly installed C or C++ compiler. Microsoft Visual Studio 2013 was used
during the development of the examples.
To access data from this stream you must write a 'client' to access the stream and
parse the data block to access its contents. The example clients provided with
Tracker illustrate the block parsing and some possible configurations for block
outputs.
For each frame in Tracker, one or more data blocks are sent. The number of
blocks per frame sent is dependent on:
Vicon Tracker User Guide For use with Tracker 3.10 Page 190 of 205
21 March 2023, Revision 1
BEYOND MOTION
On the System tab, when you click on the Local Vicon System node, the
following settings are available in the UDP Object Stream section of the
Properties pane.
Setting Description
Enabled If selected, starts the UDP streaming of data. Unlike the
data stream, the UDP stream does not maintain client
connection information. If selected, data is output whether
or not there are any connected clients.
Data Block Size The size of the UDP datagrams (data blocks). Ensure the
value selected matches the expected value for the
datagram size in the client program.
Options are 256, 512, and 1024.
Object Per Port If cleared, all objects are output on the same port.
If selected, each object is output on its own UDP port. Port
assignments are made whether or not the object is active.
The following image shows how port numbers are
assigned:
Vicon Tracker User Guide For use with Tracker 3.10 Page 191 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 192 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 193 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Translation X, Y, and Z
The values match the values received from GetSegmentGlobalTranslation
through the Vicon DataStream SDK.
• Rotation X, Y, and Z
The values match the values received from
GetSegmentGlobalRotationEulerXYZ through the Vicon DataStream SDK.
Vicon Tracker User Guide For use with Tracker 3.10 Page 194 of 205
21 March 2023, Revision 1
BEYOND MOTION
• Single object and multiple object examples on the same port are provided
using the Vicon DataStream SDK as well as the UDP stream. The only
difference in these examples is the method of data access.
• An additional example for the UDP stream is provided, which illustrates the
Object Per Port functionality. This functionality is not available using the
Vicon DataStream SDK.
• The examples use block parameters to specify the object names to be output.
Vicon Tracker User Guide For use with Tracker 3.10 Page 195 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 196 of 205
21 March 2023, Revision 1
BEYOND MOTION
Important
When you compile the code for the custom blocks, files are created in
the same folder as your source file. It is recommended that you copy the
example files to a folder other than the Tracker installation folder before
compiling, running, or modifying the example files.
To run an example:
2. The examples reference objects named Object1 and/or Object2. If you need
to change the objects that are displayed, modify the block parameters to
reference the desired object(s).
3. Open MATLAB.
A MATLAB window similar to the following is displayed:
4. Change your current folder to one containing the example you want to run.
5. Compile the example file. For more information, see the specific compile
information below. Vicon DataStream SDK examples need to link in the
proper Vicon DataStream SDK file as well.
6. Load the model by dragging the desired .mdl file from the file listing to the
command window.
Vicon Tracker User Guide For use with Tracker 3.10 Page 197 of 205
21 March 2023, Revision 1
BEYOND MOTION
This issues a uiopen command passing in the file you are dragging and opens
the model window.
7. In the model window click the Play button to run the simulation.
Tip
If the model contains a scope block to draw a graph of the data, you
must double-click on the scope to open it – it does not open
automatically.
Vicon Tracker User Guide For use with Tracker 3.10 Page 198 of 205
21 March 2023, Revision 1
BEYOND MOTION
1. Copy the CPP files from the Vicon DataStream SDK installation folder to the
folder containing the example files.
Your file names might be slightly different from those in the following
illustration, depending on the version of the Vicon DataStream SDK you are
using.
2. To compile and link C++ code, use the mex command. You need to compile
the .cpp file and then link it with the Vicon DataStream SDK .lib file. You can
do this in a single step that looks like this
Vicon Tracker User Guide For use with Tracker 3.10 Page 199 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 200 of 205
21 March 2023, Revision 1
BEYOND MOTION
All of the example S-functions have been written in C. Before using any of these
examples, they must be compiled.
• To compile C code, use the mex command, supplying the name of the .c file
as input, as follows:
ObjectPerPort folder
This folder contains two models:
TrackerSingleObject.mdl and TrackerMultipleObjects.mdl
Vicon Tracker User Guide For use with Tracker 3.10 Page 201 of 205
21 March 2023, Revision 1
BEYOND MOTION
You must configure the UDP Receive blocks in the models to match Tracker
output with regard to data block size and port numbers.
Vicon Tracker User Guide For use with Tracker 3.10 Page 202 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 203 of 205
21 March 2023, Revision 1
BEYOND MOTION
Vicon Tracker User Guide For use with Tracker 3.10 Page 204 of 205
21 March 2023, Revision 1
BEYOND MOTION
Contact Vicon
Contact Vicon
If you need more information than that supplied in the documentation or
on the Vicon Support web pages18, please contact Vicon:
18 https://www.vicon.com/support
Vicon Tracker User Guide For use with Tracker 3.10 Page 205 of 205