www.atos.

com
Table E010obs/E

Solenoid directional valves type DHU, DHO


direct operated, ISO 4401 size 06
obsolete components - availability on request
DHU and DHO are spool type, three or
four way, two or three position direct

.
connector 햵 햴 햳 햲 operated solenoid valves designed to
operate in oil hydraulic systems.

. . .
They are operated by wet and pressure
sealed solenoid 햴 with manual overri-
de and with coils certified according
the North American standard C UR US:
• DHU for DC supply;
DHU A B • DHO for DC supply with high perfor-
mance.

.
connector 햵 햴 햳 햲 Moving parts are protected, lubricated
and cushioned in oil.
Shell-moulding casting 햲 machined by

. . .
transfer lines and then cleaned by ther-
mal deburring.
Optimized flow paths largely cored with
extrawide channels to tank for low
pressure drops.
A B
DHO Interchangeable spools 햳 available in
a wide variety of configurations.
DHU and DHO valves can be supplied
1 MODEL CODE with optional devices for control of swit-
ching times.
DHU – 0 63 1/2 /A - X 24 DC ** /* Standard electric/electronic connectors
Directional control valves size 06 Synthetic fluids 햵 able to satisfy the requirements of
DHU-0 = for DC supply WG =water glycol
DHO-0 = for DC supply, high performances PE= phosphate ester modern machines for electric interfa-
Valve configuration, see table  ces characteristics.
61 = single solenoid, center plus external position, Series number
spring centered
Coils are fully encapsulated (class H).
63 = single solenoid, 2 external positions, spring offset In DHU, coils are easily replaceable
67 = single solenoid, center plus external position, Voltage code, see section 
spring offset 00 = valve without coils (only for DHU). without aid of tools.
70 = double solenoid, 2 external positions, without
springs Rugged execution suitable for outdoor
71 = double solenoid, 3 positions, spring centered X = without connector
75 = double solenoid, 2 external positions, with detent See note 2 at section  for available connec- use.
77 = double solenoid, center plus external position, tors, to be ordered separately Surface mounting ISO 4401 size 06.
without springs Coils with special connectors, see section 10
Other configurations are available on request. (only for DHU) Max flow up to 60 l/min for DHU and
Spool type, see table . XJ = AMP Junior Timer connector
XK= Deutsch connector
up to 80 l/min for DHO.
Options, see note 1 at section . XS= Lead Wire connection Max pressure: 350 bar.
Note: configuration 63, 70 and 75 are available only with spools type 0/2, 1/2 and 2/2.

2 CONFIGURATION

-071* -0700/2 -0750/2 -0630/2 -061* -067*


-0701/2 -0751/2 -0631/2

-0630/2/A -061*/A -067*/A -077*


-0631/2/A
Where the symbol doesn't show the hydraulic con-
nection (*), it depends on the central configuration
of the spool; see section .

3 SPOOLS - for intermediate passages, see tab. E001.

0 1 2 3 4 5 6 7
0/2 1/2 2/2

8 90 09 91 19 93 39 94

49 16 17 58 1/9
See note 3 at section .

E010obs
4 MAIN CHARACTERISTICS OF DHU AND DHO DIRECTIONAL VALVES

Assembly position / location Any position for all valves except for type - 070* (without springs) that must be installed with horizontal
axis if operated by impulses

Subplate surface finishing Roughness index flatness ratio 0,01/100 (ISO 1101)
Ambient temperature from -20°C to +70°C
Fluid Hydraulic oil as per DIN 51524 .... 535; for other fluids see section 
Recommended viscosity 15 ÷ 100 mm2/s at 40°C (ISO VG 15 ÷ 100)
Fluid contamination class ISO 19/16, achieved with in line filters at 25 μm value to β25 ³ 75 (recommended)
Fluid temperature -20°C +60°C (standard and /WG seals) -20°C +80°C (/PE seals)
Flow direction As shown in the symbols of tables  and 
Operating pressure
For versions with proximity switches (/FI/NC and Ports P,A,B: 350 bar;
/FI/NO versions) maximum counter pressure Port T 210 bar
allowed on T port is 5 bar
Rated flow See diagrams Q/Δp at section 
Maximum flow 60 l/min for DHU; 80 l/min for DHO, see operating limits at section 

4.1 Coils characteristics


Insulation class H (180°C) Due to the occuring surface temperatures of the solenoid coils, the European standards
EN563 and EN982 must be taken into account
Connector protection degree DIN 43650 IP 65
Relative duty factor 100%
Supply voltage and frequency See electric feature 
Supply voltage tolerance ± 10%
Certification C UR US

5 NOTES
1 Options
A = Solenoid mounted at side of port B (only for single solenoid valves). In standard versions, solenoid is mounted at side of port A.
WP = prolonged manual override protected by rubber cap (standard for DHO models) - see section 12 .
L1, L2, L3 = device for switching time control, installed in the valve solenoid (only for DHU and DHO models).
For spools 4 and 4/8 only device L3 is available.
F* = with proximity switch for monitoring spool position: see tab. E110.
MV, MO = auxiliary hand lever positioned vertically (MV) or horizontally (MO). For available configuration and dimensions see table E138.

2 Type of electric/electronic connector DIN 43650, to be ordered separately


SP-666 = standard connector IP-65, suitable for direct connection to electric supply source.
SP-667 = as SP-666, but with built-in signal led.
SP-669 = with built-in rectifier bridge for supplying DC coils by alternate current (AC 110V and 230V - Imax 1A).
E-SD = electronic connector which eliminates electric disturbances when solenoid valves are de-energized.

3 Spools
- spools type 0/2, 1/2, 2/2 are only used for two position valves: single solenoid valves, type DH*-063*/2 and double solenoid valves type
DH*-070*/2 and DH*-075*/2.
- spools type 0 and 3 are also available as 0/1 and 3/1 with restricted oil passages in central position, from user ports to tank.
- spools type 1, 4 and 5 are also available as 1/1, 4/8 and 5/1. They are properly shaped to reduce water-hammer shocks during the swiching.
- spools type 1, 3, 8 and 1/2 are available as 1P, 3P, 8P and 1/2P to limit valve internal leakages.
- spool type 1/9 has closed center in rest position but it avoids the pressurization of A and B ports due to the internal leakages.
- Other types of spools can be supplied on request.

6 ELECTRIC FEATURES

External supply Power (1) Coil can be supplied also with 60


Voltage Type of Code of spare coil Colour of
Valve nominal voltage consumption Hz of voltage frequency: in this
code connector coil label
± 10% (2) DHU case the performances are redu-
6 DC 6 DC SP-COU-6DC/ 80 brown ced by 10 ÷15% and the power
9 DC 9 DC SP-COU-9DC /80 light blue
consumption is 55 VA.
12 DC 12 DC SP-COUR-12DC /10 green
14 DC 14 DC SP-COUR-14DC /10 brown (2) Average values based on tests
18 DC 18 DC SP-666 SP-COU-18DC /80 blue preformed at nominal hydraulic
24 DC 24 DC or 33 W SP-COUR-24DC /10 red condition and ambient/coil tempe-
28 DC 28 DC SP-667 SP-COUR-28DC /10 silver
DHU rature of 20°C.
48 DC 48 DC SP-COU-48DC /80 silver
110 DC 110 DC SP-COUR-110DC /10 black (3) When solenoid is energized, the
125 DC 125 DC SP-COU-125DC /80 silver inrush current is approx 3 times the
220 DC 220 DC SP-COUR-220DC /10 black holding current. Inrush current
110/50 AC 40 VA
110RC SP-COUR-110RC /10 gold values correspond to a power con-
120/60 AC 35 VA
SP-669 sumption of about 150 VA.
230/50 AC 40 VA
230RC SP-COUR-230RC /10 blue
230/60 AC 35 VA

External supply Power External supply Power


Voltage Type of Voltage Type of
Valve nominal voltage consumption nominal voltage consumption
code connector code connector
± 10% (2) ± 10% (2)
12 DC 12 DC 110/50 AC 40 W
SP-666 32 W 110 DC
24 DC 24 DC 120/60 AC 35 W
DHO or SP-669
110 DC 110 DC 230/50 AC 40 W
SP-667 40W 220 DC
220 DC 220 DC 230/60 AC 35 W
7 Q/ΔP DIAGRAMS based on mineral oil ISO VG 46 at 50°C DHU DHO
D D
Flow direction B B
P®A P®B A®T B®T P®T

Valve pressure drop Δp [bar]

Valve pressure drop Δp [bar]


Spool type
A
0 C C C C
A C
0/2, 1, 1/2 A A A A

2, 3 A A C C
C
2/2, 4, 5, 9* D D D D A

6 A A C A

7 A A A C

8 C C B B
Flow rate [l/min] Flow rate (l/min)

8 OPERATING LIMITS based on mineral oil ISO VG 46 at 50°C


The diagrams have been obtained with warm solenoids and power supply at lowest value (Vnom - 10%). The curves refer to application with symmetrical
flow through the valve (i.e. P®A and B®T). In case of asymmetric flow and if the valves have the devices for controlling the switching times the operating
limits must be reduced.
DHU DHO

M
M
Inlet pressure [bar]

Inlet pressure [bar]


S
T S V T
V

Flow rate [l/min] Flow rate [l/min]


M= Spools 0, 1, 1/2, 8 M= Spools 0, 1, 1/2, 8.
S= Spools 0/2, 3, 6, 7 S= Spools 0/2, 3, 6, 7.
V= Spools, 2, 2/2, *9, 9* V= Spools 2, 2/2, *9, 9*
T= Spools 4, 5 T= Spools 4, 5.

9 SWITCHING TIMES (average values in msec)


DHU DHO
Valve Switch-on Switch-on Switch-off Valve Switch-on Switch-on Switch-off
Test conditions: AC DC AC DC
DHU + SP-666
SP-667 –– 45 20 DHO + SP-666 –– 50 20
SP-667
- 36 l/min; 150 bar
- nominal voltage DHU + SP-669 45 –– 80 DHO + SP-669 50 –– 80
- 2 bar of counter pressure on port T DHU + E-SD –– 45 50 DHO + E-SD –– 50 50
- mineral oil: ISO VG 46 at 50°C.
DHU-*/L1 –– 60 60 DHO-*/L1 –– 60 60
The elasticity of the hydraulic circuit and the DHU-*/L2 –– 80 80 DHO-*/L2 –– 80 80
variations of the hydraulic characteristics and
temperature affect the response time. DHU-*/L3 –– 110 150 DHO-*/L3 –– 150 150

10 COILS TYPE COU* and COUR* WITH SPECIAL CONNECTORS (only for DHU)

Options -XJ Options -XK Options -XS

Coil type SP-COUJ, SP-COURJ Coil type SP-COURK Coil type SP-COUS, SP-COURS
AMP Junior Timer connector (not available for COU) Lead Wire connection
Protection degree IP67 Deutsch connector Cable lenght = 180 mm
DT-04-2P male
Protection degree IP67

Note: The above coils are available only for voltage supply 12, 14, 24 and 28 VDC. For the characteristics refer to standard coils features - see sect. 

E010obs
11 DIMENSIONS [mm]

ISO 4401: 2005


Mounting surface: 4401-03-02-0-05
P = PRESSURE PORT
Fastening bolts: A, B = USE PORT
4 socket head screws M5x50 class 12.9 T = TANK PORT
Tightening torque = 8 Nm For the max pressures on ports, see section
Seals: 4 OR 108
Ports P,A,B,T: Ø = 7.5 mm (max).

DHU-06 DHU-07

Mass: 1,8 kg
Mass: 1,5 kg

DHO-06 DHO-07

Mass: 1,9 kg Mass: 2,6 kg

Overall dimensions refer to valves with connectors type SP-666

12 OPTION /WP (for DHU) 13 ELECTRIC CONNECTORS ACCORDING TO DIN 43650


The connectors must be ordered separately
SP-666, SP-667 (for AC or DC supply) SP-669 (for AC supply)

DHU CONNECTOR WIRING


SP-666, SP-667 SP-669

1 = Positive 1,2 = Supply voltage VAC


2 = Negative 3 = Coil ground
= Coil ground
SUPPLY VOLTAGES
SP-666 SP-667 110/50 AC
All 24 AC or DC 110/60 AC
voltages 110 AC or DC 230/50 AC
220 AC or DC 230/60 AC

Note: for electronic connectors type E-SD, see tab. K500

14 MOUNTING SUBPLATES

Ø Counterbore
GAS Ports Mass
Model Ports location [mm]
A-B-P-T [kg]
A-B-P-T

BA-202 Ports A, B, P, T underneath; 3/8" – 1,2

BA-204 Ports P, T underneath; ports A, B on lateral side 3/8" 25,5 1,8

BA-302 Ports A, B, P, T underneath 1/2" 30 1,8

The subplates are supplied with 4 fastening bolts M5x50. Also available are multi-station subplates and modular subplates. For further details see table K280.