Calculations 1.4

The document contains detailed structural calculations for a building, including slab, beam, frame, and column specifications, as well as air conditioning and lighting calculations. It outlines various parameters such as spans, loads, duct sizes, and lighting requirements for different spaces. Additionally, it includes tables for air-cooled package units, chillers, and air handling units with their respective sizes and performance metrics.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

Calculations 1.4

The document contains detailed structural calculations for a building, including slab, beam, frame, and column specifications, as well as air conditioning and lighting calculations. It outlines various parameters such as spans, loads, duct sizes, and lighting requirements for different spaces. Additionally, it includes tables for air-cooled package units, chillers, and air handling units with their respective sizes and performance metrics.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 13

Structure Calulations

Building Data X Y H Floors D+L kg/m2


Strucutural Grid Spans 5.0 7.0 4.0 1 500
Analysis 1/2 Way L. Span S. Span
Data 2 7.0 5.0
Slabs Span (m) Factors Depth (cm) Ideal Span
1-Way Simple 0.0 30 0 4
1-Way Continuous 0.0 35 0 5
2-Way Simple 7.0 40 18 6
2-Way Continuous 7.0 45 16 7
1-Way Hollow Blk. Simple 0.0 20 0 5<Span<6
1-Way Hollow Blk. Cont. 0.0 25 0 6<Span<8
2-Way Hollow Blk. Simple 7.0 35 20 8<Span<11
2-Way Hollow Blk. Cont. 7.0 40 18 9<Span<12
Flat Slab 7.0 35 20 8<Span<10
Waffle Slab 7.0 30 24 10<Span<16
Folded Slab 7.0 10 70 15<Span<30
Beams L.Span Factors L.Depth S.Span S.Depth
Concrete Simple 7.0 10 70 5.0 50
Concrete Continuous 7.0 12 60 5.0 45
Steel Section 7.0 20 35 5.0 25
Concrete Cantilever 5 5.0 100
Frames L.Span Factors Depth (cm) Leg (cm) Leg Width
2-Hinged 7.0 14 50 25 30, 35, 40
2-Fixed 7.0 16 45 45 30, 35, 40
Columns T. Load Stress Area W (cm) L (cm)
Full 17500 50 350 25 25
Three-Quarter 13125 50 262.5 25 25
Half 8750 50 175 25 25
Quarter 4375 50 87.5 25 25
Air Condition Calculations
CONSTANTS
1T.R. 48
1T.R. 350
Air Speed Main Duct 1000
Air Speed Diffuser 600
Length of Main Duct < 25 m
Length of Secondary. Duct <18 m
INPUT
Number of Spaces 1 7 0 0 0
Length 60 8 0 0 0
Width 6 12 0 0 0
Height 4 5 0 0 0
Sub-total Volume 1440 3360 0 0 0
Total Volume
OUTPUT
Number of Units 1 2 3 4 5
Total Space Volume 4800 4800 4800 4800 4800
Ton Refregiration, TR 100 50 33 25 20
Total Air Change, CFM 35000 17500 11667 8750 7000
Area of Duct, sq.ft. 35 17.5 11.7 8.8 7
Area of Duct, sq.cm. 31500 15750 10530 7920 6300
Circular Duct
Diameter, cm 200 142 116 100 90
Rectangular Duct 1:2
Height, cm 132 93 76 66 59
Width, cm 263 186 152 132 118
Rectangular Duct 1:3
Height, cm 110 78 64 55 49
Width, cm 330 233 191 165 147
# of Diffusers 58 29 19 14 11
Table 1 - Air Cooled Package Units Size (Carrier)
Performance Unit Length mm Total Length mm
Model TR C.F.M. Length Width Hight Length
55 5 2000 900 780 1605 2900
90 7 3000 1340 790 1830 3340
110 9 3500 1340 790 1830 3340
145 12 6000 1595 870 2145 3595
180 14 6000 1595 870 2145 3595
240 19 7000 2050 1080 2035 4050

0
0 Table 2 - Central Air/Water Cooled Chillers Units Size
0 Performance Unit Length mm Length + Service Area mm
0 Model TR C.F.M. Length Width Hight Length
0 XX 60-1000 Var 8000 2000 2000 9000
4800

6 Table 3 - Central Air Handeling Units Size (Saivez)


4800 Performance Unit Length mm
17 Model TR M3/H CFM Length Width Hight
5833 ST 20-20 4 1800 1060 1350 1000 750
5.8 ST 25-25 5 2250 1330 1400 1100 750
5220 ST 33-25 6 3000 1770 1400 1200 750
ST 44-29 8 4000 2360 1600 1400 800
82 ST 50-29 10 4600 2710 1600 1400 900
ST 59-33 11 5300 3120 1700 1400 950
54 ST 67-33 13 6100 3590 1700 1550 950
107 ST 79-37 15 7200 4240 1900 1500 1050
ST 89-37 16 8100 4770 1900 1650 1050
45 ST 100-41 18 9000 5300 1950 1750 1100
134 ST 111-41 20 10000 5890 1950 1850 1100
9 ST 122-45 23 11000 6480 1950 1750 1350
ST 138-45 26 12500 7360 1950 1950 1350
ST 154-49 28 14000 8240 2100 2000 1350
ST 177-49 32 16000 9420 2100 2150 1350
ST 200-58 36 18000 10590 2300 2200 1500
ST 233-58 43 21000 12360 2300 2500 1500
ST 264-66 50 24000 14120 2700 2500 1700
ST 303-66 56 27000 15890 2700 2750 1700
ST 346-74 63 31000 18240 2850 2750 1850
ST 373-74 66 34000 20000 2850 3050 1850
ST 420-82 68 37500 22060 3050 2900 2100
ST 470-82 86 42000 24710 3050 3250 2100
ST 555-92 95 48000 28240 3550 3150 2500
ST 625-92 114 56000 32950 3550 3550 2500
ST 715-104 128 64000 37650 3750 3750 2650
(Carrier)
Total Length mm
Width Hight
1780 1605
1790 1830
1790 1830
1870 2145
1870 2145
2080 2035

s Units Size
Length + Service Area mm
Width Hight
4000 2000

ts Size (Saivez)
Length + Service Area mm
Length Width Hight
2350 3000 750
2400 3100 750
2400 3200 750
2600 3400 800
2600 3400 900
2700 3400 950
2700 3550 950
2900 3500 1050
2900 3650 1050
2950 3750 1100
2950 3850 1100
2950 3750 1350
2950 3950 1350
3100 4000 1350
3100 4150 1350
3300 4200 1500
3300 4500 1500
3700 4500 1700
3700 4750 1700
3850 4750 1850
3850 5050 1850
4050 4900 2100
4050 5250 2100
4550 5150 2500
4550 5550 2500
4750 5750 2650
Lighting Calculations
Space Length (m) 52
Space Width (m) 20
Space Height (m) 4
Height of Working plan (m) 1.5
Space Area 1040
Illumination Required For Space (Lux) 300
Luminous Efficiency 0.4
Maintenace Factor 0.8
Type of Light Bulb Filament Fluorecent
Lumen/Watt Conversion Factor 14 65
Total Wattage 69643 15000
Light Bulb Power (Watt) 200 40
No. of Lamps 348 375
No. of Lamps in Fixture 4 6
Total Number and Distribution of Fixtures 87 63
No. of Fixtures in Length direction 16 13
No. of Fixtures in Width direction 5 5
Space between Fixtures in Lenght direction (m) 3.25 4.00
Space between Fixtures in Width direction (m) 3.68 4.16
Light Distribution Check 1.4>Space/Height>0.8
Space / Height ratio in Length direction 1.30 1.60
Space / Height ratio in Width direction 1.47 1.66

Actual Illumination (Lux) 300 300


52 Activity Table
20 Lux Public Buildings Hotels
4 20 Service (Min)
1.5 50 Circulation, Parking
1040 100 Auditoria, Religious, Docks Hotel Rooms
300 200 Lounge, Foyer Hotel Dinning
0.4 300 Offices, Shops, Library, Exhibits Hotel Entrance
0.8 500 Drawing Offices, Inspection Hotel Kitchen
Mercury 750 Proof Reading, Labs
50 1000 Drawing, Fine work,
19500 2000 Precise work
250
78
1 Light Bulb Power (Watt)
78 Filament Fluorecent Mercury
15 15 15
5 20 20
3.47 25 25
3.85 40 40
pace/Height>0.8 60 65
1.39 75
1.54 100
150 125
300 200 250
300 400
500 700
1000 1000
2000 2000
Residential

Bedroom
Living, Bathroom
Bed-Head
Kitchen
Makeup, reading
Sewing
Serial Material
C Ceiling
C1 Overhead sound board 1200x450x50 mm
C2 Metal planks w 14% slots w glass fiber behind
C3 Metal tiles 5% perforated w 20 mm glass fiber quilt & ceiling void
C4 Acoustic palster (13 mm) on metal lathing
C5 Fissured mineral tiles 300 mm & ceiling void
C6 Profiled metal deck
C7 Plasterboard (13 mm) ceiling over large air space
W Wall Linings
W1 Brickwork: Fairfaced
W2 Brickwork: Painted
W3 Brickwork: Plastered
W4 Blockwork: Fairfaced
W5 Concrete: textured finish
W6 Acoustic (9 mm) plaster on solid wall
W7 Woodwool slabs on solid backing: 50 mm thick
W8 Woodwool slabs on solid backing: 100 mm thick
W9 Prescreed woodwool slabs on 6000 mm air gap
W10 Plasterboard (9 mm) on 18 mm airspace filled w glass fiber to solid back
W11 Plywood (12 mm) on 30 mm airspace filled w glass fiber to solid back
W12 Glass (6 mm), large panes
W13 Stretched, lightweight fabric wall hanging
W14 Heavy curtain material hung in folds
W15 Glass fiber quilt to solid backing: 25 mm thick
W16 Glass fiber quilt to solid backing: 50 mm thick
W17 Glass fiber quilt to solid backing: 100 mm thick
W18 Glass fiber 100/100 mm airsapce
W19 Mineral wool on solid backing: 25 mm thick
W20 Mineral wool on solid backing: 50 mm thick
W21 Mineral wool on 25/25 airspace
W22 Mineral wool on 50/50 airspace
F Floors
F1 Thin contract carpet on solid floor
F2 Thick carpet on underlay
F3 Rubber flooring
F4 Vinyl sheets
F5 Marble
F6 Ceramic tiles
F7 Reinforced concret
F8 Grano
F9 Water (swimming pool)
F10 Ice
T Other
T1 Seated audience
T2 Standing adults
T3 Wooden seats
T4 Upholstered seats
Absorption Co.
Sound Calculations
0.96 Finishing-01 Finishing-02
0.8 Plastered Brick Glass
0.55 Wall 1 Area (m2) Absorption Co. AxAC Area (m2)
0.5 20.0 0.55 11 20.0
0.4 Plastered Brick Finishing Material
0.3 Wal l2 Area (m2) Absorption Co. AxAC Area (m2)
0.2 32.0 0.55 17.6 0.0
Plastered Brick Glass
0.02 Wall 3 Area (m2) Absorption Co. AxAC Area (m2)
0.01 20.0 0.03 0.6 20.0
0.3 Plastered Brick Finishing Material
0.5 Wall 4 Area (m2) Absorption Co. AxAC Area (m2)
0.04 32.0 0.03 0.96 0.0
0.3 Metal Tiles Finishing Material
0.6 Ceiling Area (m2) Absorption Co. AxAC Area (m2)
0.9 80.0 0.55 44 0
0.7 Rubber Finishing Material
0.2 Floor Area (m2) Absorption Co. AxAC Area (m2)
0.2 80.0 0.05 4 0.0
0.2
0.2 Persons (chairs)
0.3
0.6
Total AC x Area
0.8
0.8
Volume (m3)
0.9
0.7
RT
1.0
0.7
0.9

0.05
0.7
0.05
0.05
0.05
0.05
0.02
0.02
0.01
0.01

0.44
0.42
0.3
0.27
Sound Calculations
Finishing-02 Finishing-03 Total ACx A Volume (m3)
Glass Finishing Material 300
Absorption Co. AxAC Area (m2) Absorption Co. AxAC 15 400
0.20 4 0.0 0.00 0 500
Finishing Material Finishing Material 600
Absorption Co. AxAC Area (m2) Absorption Co. AxAC 17.6 700
0.00 0 0.0 0.00 0 800
Glass Finishing Material 900
Absorption Co. AxAC Area (m2) Absorption Co. AxAC 4.6 1000
0.20 4 0.0 0.00 0 1200
Finishing Material Finishing Material 1400
Absorption Co. AxAC Area (m2) Absorption Co. AxAC 0.96 1600
0.00 0 0.0 0.00 0 1800
Finishing Material Finishing Material 2000
Absorption Co. AxAC Area (m2) Absorption Co. AxAC 44 2200
0.00 0 0.0 0.00 0 2400
Finishing Material Finishing Material 2600
Absorption Co. AxAC Area (m2) Absorption Co. AxAC 4 2800
0.00 0 0.0 0.00 0 3000
Type 3200
Area (m2) Absorption Co. ACxNO. 16.8 3400
40 0.42 16.8 3600
3800
Total AC x Area 102.96
4000

Volume (m3) 320

RT 0.497280497
RT Optimium Upper Limit Lower Limit
0.4 0.6 0.2
0.5 0.75 0.25
0.5 0.75 0.25
0.5 0.75 0.25
0.6 0.9 0.3
0.6 0.9 0.3
0.6 0.9 0.3
0.6 0.9 0.3
0.6 0.9 0.3
0.6 0.9 0.3
0.7 1.05 0.35
0.7 1.05 0.35
0.7 1.05 0.35
0.7 1.05 0.35
0.7 1.05 0.35
0.7 1.05 0.35
0.7 1.05 0.35
0.7 1.05 0.35
0.8 1.2 0.4
0.8 1.2 0.4
0.8 1.2 0.4
0.8 1.2 0.4
0.8 1.2 0.4
Systems Quick Calculation

SUPERVISION:
Prof. Dr. Ali Faramawy
Arch. Tarek Hassan
Working Drawing 1
3rd Year, 2001-2002
Department of Architectural Engineering
Ain Shams University

ADVISORS:
Prof. Dr. Abdel-Salam Mokhtar; Eng. Yasser Samir; Civil
Prof. Dr. Ahmed El Assy, Mechanical
Dr. Hanan Sabry, Lighting
Dr. Ahmed El-Khatib, Sound

STUDENTS
Structure Module:
Noha Saad
Hoda Ahmed
Maha Ataa
Air Condition Module:
Mohamed Hisham
Lighting Module:
Heba Houseiny
Nermen Sabry
Asmaa Salama
Sound Module:
Micheal Shehata
Moaaz Awsam