Tubular Framing Computation
Tubular Framing Computation
AT 2.72M LENGTH
AT 1.75M LENGTH
Vertical tubular = 3.40 m x 8 27.2 m
Horizontal= 1.75 m x 6 10.5 m
Bridging = 0.15 m x 12 1.8 m
0.10 m x 10 1 m
40.5 M
AT 5.50M LENGTH
Vertical tubular = 3.40 m x 7 23.8 m
1.80 m x 8 14.4 m
0.56 m x 14 7.84 m
Horizontal= 5.50 m x 8 44 m
Bridging = 0.15 m x 12 1.8 m
0.10 m x 10 1 m
92.84 M
AT 0.90M LENGTH
Vertical tubular = 3.40 m x 4 13.6 m
Horizontal= 0.90 m x 14 12.6 m
26.2 M
AT 7.50M LENGTH
Vertical tubular = 3.40 m x 7 23.8 m
1.80 m x 12 21.6 m
0.56 m x 26 14.56 m
Horizontal= 7.50 m x 8 60 m
Bridging = 0.10 m x 22 2.2 m
122.16 M
AT 3.30M LENGTH
Vertical tubular = 3.40 m x 7 23.8 m
0.56 m x 14 7.84 m
Horizontal= 3.30 m x 7 23.1 m
54.74 M
AT 4.20M LENGTH
Vertical tubular = 2.60 m x 2 5.2 m
1.80 m x 12 21.6 m
Horizontal= 4.20 m x 2 8.4 m
1.20 m x 8 9.6 m
Bridging = 0.10 m x 22 2.2 m
47 M
AT LIBRARY PARTITION
Vertical tubular = 3.40 m x 15 51 m
Horizontal= 7.75 m x 7 54.25 m
Bridging = 0.10 m x 22 2.2 m
107.45 M
x2 214.9
6
220.9