1.2 Add the ESEER value : 32HP~90HP and modify the spec. : weight and sound power 16.05.04
Nomenclature
Outdoor Units
Model Names
AM 140 K X V A G H EU
(1) (2) (3) (4) (5) (6) (7) (8) Buyer
M DVM S Eco
(2) Capacity
x 1/10 HP (3 digits) (6) Feature2
A Standard + General Temp.+ Module
H 2014
R Heat Recovery
Accessory
Classification Product Image Model Remark
Integrated
Management S-NET 3 MST-P3P -
System
PIM MIM-B16N -
Wireless remote
MR-EH00 -
controller
MWR-WE10N
A/C+VTL
Wired remote (Multi function)
controller
Individual Control MWR-WW00N DVM S Hydro Unit
System
MWR-SH00N -
Simplified wired
remote controller
MWR-VH02 ERV
Cassette, Wall-mount,
External room sensor MRW-TA
Ceiling, Duct, Console
Compatible interface
MIM-N01 Nasa-No Nasa
module
Others
External contact
MIM-B14 -
interface module
S-Converter MIM-C02N -
MTFC
(Multi tenant function MCM-C210N -
controller)
Wireless signal
MRK-A10N -
receiver
Q
Accessory
Product Image Model Remark
MXJ-YA1509M 15.0 kW and below
MEV-E24SA
1 Indoor
MEV-E32SA
MXD-E24K132A
MXD-E24K200A 2 Indoor
MXD-E24K232A
MXD-E24K300A
3 Indoor
MXD-E32K224A
MXD-E32K300A
MXD-K025AN 7.0kW~8.75kW
MXD-K050AN 14.0kW~17.5kW
MXD-K100AN 28.0kW~35.0kW
R
Accessory
Product Image Model Remark
MXD-A38K2A 8~12HP
MXD-A58K2A 18~26HP
4Way Cassette S
MSD-CAN1
4Way Cassette S(600x600)
S-Plasma Ion KIT
MSD-EAN1 ERV-Plus
Motion detect
MCR-SMA 4Way Cassette S (600x600)
Sensor
S
Outdoor
1 Line-up
2 Specifications
3 Operation limit
4 Dimensional drawing
5 Electrical wiring diagram
6 Sound pressure level
7 Sound power level
8 Cycle diagram
1 Line-up
Outdoor Units
Compressor
Model Name - DS-GA046FAVADOx1 DS-GB066FAVBx1 DS-GB066FAVBx1
External
Dimension Net Dimensions (WxHxD) mm 880x1,695x765 880x1,695x765 880x1,695x765
Compressor
Model Name - DS-GB066FAVBx1 DS4GJ5080FVAx1 DS4GJ5080FVAx1
External
Dimension Net Dimensions (WxHxD) mm 1,295x1,695x765 1,295x1,695x765 1,295x1,695x765
Compressor
Model Name - DS-GB052FAVBx2 DS-GB066FAVBx2 DS-GB066FAVBx2
External
Dimension Net Dimensions (WxHxD) mm 1,295x1,695x765 1,295x1,695x765 1,295x1,795x765
Compressor
Model Name - DS-GB066FAVBx2 DS-GB070FAVAx2 DS4GJ5080FVAx2
External
Dimension Net Dimensions (WxHxD) mm 1,295x1,795x765 1,295x1,795x765 1,295x1,795x765
Compressor
Model Name - DS-GB066FAVBx3 DS-GB066FAVBx3 DS-GB066FAVBx3
External
Dimension 1,295x1,695x765 + 1,295x1,695x765 +
Net Dimensions (WxHxD) mm (1,295x1,695x765)x2
880x1,695x765 880x1,695x765
Compressor
Model Name - DS4GJ5080FVAx1 + DS- DS4GJ5080FVAx1 + DS- DS-GB052FAVBx2 + DS-
GB066FAVBx2 GB066FAVBx2 GB066FAVBx2
External
Dimension Net Dimensions (WxHxD) mm (1,295x1,695x765)x2 (1,295x1,695x765)x2 (1,295x1,695x765)x2
Compressor
Model Name - DS-GB066FAVBx4 DS4GJ5080FVAx3 DS4GJ5080FVAx3
External
Dimension 1,295x1,695x765 + 1,295x1,695x765 +
Net Dimensions (WxHxD) mm (1,295x1,695x765)x2 1,295x1,795x765 1,295x1,795x765
Compressor
Model Name - DS-GB052FAVBx2 + DS-GB066FAVBx2 + DS-GB066FAVBx2 +
DS4GJ5080FVAx2 DS4GJ5080FVAx2 DS4GJ5080FVAx2
External
Dimension 1,295x1,695x765 + 1,295x1,695x765 +
Net Dimensions (WxHxD) mm 1,295x1,795x765 1,295x1,795x765 (1,295x1,795x765)x2
Compressor
Model Name - DS-GB066FAVBx2 + DS-GB070FAVAx2 + DS4GJ5080FVAx4
DS4GJ5080FVAx2 DS4GJ5080FVAx2
External
Dimension Net Dimensions (WxHxD) mm (1,295x1,795x765)x2 (1,295x1,795x765)x2 (1,295x1,795x765)x2
Output kW x n (6.39x2) + (7.81x2) + (6.39) (6.39x2) + (7.81x2) + (6.39) (6.39) + (6.39x2) + (7.81x2)
Compressor
Model Name - DS-GB066FAVBx3 + DS-GB066FAVBx3 + DS-GB066FAVBx3 +
DS4GJ5080FVAx2 DS4GJ5080FVAx2 DS4GJ5080FVAx2
CMM 290.0 + 340.0 + 170.0 290.0 + 340.0 + 220.0 255.0 + 290.0 + 340.0
Fan
Air Flow Rate
l/s 4,833.3 + 5,666.7 + 2,833.3 4,833.3 + 5,666.7 + 3,666.7 4,250.0 + 4,833.3 + 5,666.7
Net Weight kg 285.0 + 350.0 + 197.0 285.0 + 350.0 + 210.0 226.0 + 285.0 + 350.0
Shipping Weight kg 305.0 + 372.0 + 213.0 305.0 + 372.0 + 223.0 246.0 + 305.0 + 372.0
1,363x1,887x832 + 1,363x1,887x832 +
Shipping Dimensions (1,363x1,887x832)x2 +
mm 1,363x1,987x832 + 1,363x1,987x832 +
(WxHxD) 1,363x1,987x832
948x1,887x832 948x1,887x832
Output kW x n (7.81) + (6.39x2) + (7.81x2) (7.81) + (6.39x2) + (7.81x2) (5.18x2) + (6.39x2) + (7.81x2)
Net Weight kg 253.0 + 285.0 + 350.0 255.0 + 285.0 + 350.0 277.0 + 285.0 + 350.0
Shipping Weight kg 273.0 + 305.0 + 372.0 275.0 + 305.0 + 372.0 297.0 + 305.0 + 372.0
External
Dimension (1,295x1,695x765)x2 + (1,295x1,695x765)x2 + (1,295x1,695x765)x2 +
Net Dimensions (WxHxD) mm 1,295x1,795x765 1,295x1,795x765 1,295x1,795x765
Compressor
Model Name - DS-GB066FAVBx4 + DS-GB066FAVBx4 + DS-GB066FAVBx4 +
DS4GJ5080FVAx2 DS4GJ5080FVAx2 DS4GJ5080FVAx2
Net Weight kg 285.0x2 + 350.0 285.0 + 333.0 + 350.0 285.0 + 333.0 + 350.0
Shipping Weight kg 305.0x2 + 372.0 305.0 + 355.0 + 372.0 305.0 + 355.0 + 372.0
External
Dimension (1,295x1,695x765)x2 + 1,295x1,695x765 + 1,295x1,695x765 +
Net Dimensions (WxHxD) mm 1,295x1,795x765 (1,295x1,795x765)x2 (1,295x1,795x765)x2
External
Dimension 1,295x1,695x765 + 1,295x1,695x765 +
Net Dimensions (WxHxD) mm (1,295x1,795x765)x3
(1,295x1,795x765)x2 (1,295x1,795x765)x2
Compressor
Model Name - DS-GB066FAVBx2 + DS-GB070FAVAx2 + DS4GJ5080FVAx6
DS4GJ5080FVAx4 DS4GJ5080FVAx4
External
Dimension Net Dimensions (WxHxD) mm (1,295x1,795x765)x3 (1,295x1,795x765)x3 (1,295x1,795x765)x3
On heating operation, frost can be formed on heat exchanger according to outdoor temperature.
(Frost on heat exchanger results in decreasing the performance.)
To remove frost on heat exchanger of outdoor unit, defrost operation is carried out periodically.
During defrost operation, capacity of outdoor unit may decrease.
The decrement is not considered to the individual capacity tables.
4 Dimensional drawing
Outdoor
AM080JXVAGH/EU, AM100JXVAGH/EU, AM120JXVAGH/EU
4 Dimensional drawing
Outdoor
AM140KXVAGH/EU, AM160KXVAGH/EU, AM180KXVAGH/EU, AM200KXVAGH/EU, AM220KXVAGH/EU
Units : mm / inches
1295
[4'-3"]
[2'-6"]
765
36
[1 1/2"]
[5'-6 3/4"]
1695
⑥
⑥
[2'-0 1/4"]
[2'-2 1/2"]
616
671
[1'-7 1/2"]
[1'-10"]
557
492
[9 1/2"]
[6 3/4"]
241
172
122 51 107
⑤ [4 1/4"]
[4 3/4"] [2"] ① ② ④ ③
⑤
③ 575
[1'-10 3/4"]
[2'-7 3/4"]
[2'-6"]
761
803
1295
⑧ [4'-3"]
Table of descriptions
1 Gas Ref. pipe 7 Knock-out Hole for Ref. Piping
2 Liquid Ref. pipe 8 Anchor Bolt Hole
3 Power wiring conduit 9
4 Communication wiring conduit 10
5 Power wiring conduit 11
6 Communication wiring conduit 12
4 Dimensional drawing
Outdoor
AM240KXVAGH/EU, AM260KXVAGH/EU, AM280KXVAGH/EU, AM300KXVAGH/EU
5 Electrical wiring diagram
Outdoor
AM080JXVAGH/EU, AM100JXVAGH/EU, AM120JXVAGH/EU, AM140KXVAGH/EU, AM200KXVAGH/EU, AM220KXVAGH/EU
5 Electrical wiring diagram
Outdoor
AM160KXVAGH/EU, AM180KXVAGH/EU, AM240KXVAGH/EU, AM260KXVAGH/EU, AM280KXVAGH/EU, AM300KXVAGH/EU
6 Sound pressure level
Outdoor
Unit: dB(A)
Model Cooling
AM080JXVAGH/EU 57
AM100JXVAGH/EU 58
AM120JXVAGH/EU 62
AM140KXVAGH/EU 61
Note
* Specifications may be subject to change without prior notice
1) These operation values were obtained in an anechoic room.
2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room
3) Operation sound level may differ depending on operation and ambient conditions.
NC curve
1) AM080JXVAGH/EU 2) AM100JXVAGH/EU
75 75
Cooling
70 Cooling 70
65 65
NC 65 NC 65
60 60
NC 60 NC 60
Sound pressure level(dB)
55 55
NC 55 NC 55
50 50
NC 50 NC 50
45 45
NC 45 NC 45
40 40
NC 40 NC 40
35 35
NC 35 NC 35
30 30
NC 30 NC 30
25 25
NC 25 NC 25
20 20
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz) Octave band center frequency(Hz)
3) AM120JXVAGH/EU 4) AM140KXVAGH/EU
75 75
Cooling
70 70
65 65 Cooling
NC 65 NC 65
60 60
NC 60 NC 60
Sound pressure level(dB)
55 55
NC 55 NC 55
50 50
NC 50 NC 50
45 45
NC 45 NC 45
40 40
NC 40 NC 40
35 35
NC 35 NC 35
30 30
NC 30 NC 30
25 25
NC 25 NC 25
20 20
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz) Octave band center frequency(Hz)
6 Sound pressure level
Outdoor
Unit: dB(A)
Model Cooling
AM160KXVAGH/EU 63
AM180KXVAGH/EU 64
AM200KXVAGH/EU 65
AM220KXVAGH/EU 65
Note
* Specifications may be subject to change without prior notice
1) These operation values were obtained in an anechoic room.
2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room
3) Operation sound level may differ depending on operation and ambient conditions.
NC curve
1) AM160KXVAGH/EU 2) AM180KXVAGH/EU
75 75
70 70 Cooling
Cooling
65 65
NC 65 NC 65
60 60
NC 60 NC 60
Sound pressure level(dB)
55 55
NC 55 NC 55
50 50
NC 50 NC 50
45 45
NC 45 NC 45
40 40
NC 40 NC 40
35 35
NC 35 NC 35
30 30
NC 30 NC 30
25 25
NC 25 NC 25
20 20
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz) Octave band center frequency(Hz)
3) AM200KXVAGH/EU 4) AM220KXVAGH/EU
75 75
70 70 Cooling
Cooling
65 65
NC 65 NC 65
60 60
NC 60 NC 60
Sound pressure level(dB)
55 55
NC 55 NC 55
50 50
NC 50 NC 50
45 45
NC 45 NC 45
40 40
NC 40 NC 40
35 35
NC 35 NC 35
30 30
NC 30 NC 30
25 25
NC 25 NC 25
20 20
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz) Octave band center frequency(Hz)
6 Sound pressure level
Outdoor
Unit: dB(A)
Model Cooling
AM240KXVAGH/EU 66
AM260KXVAGH/EU 66
AM280KXVAGH/EU 69
AM300KXVAGH/EU 69
Note
* Specifications may be subject to change without prior notice
1) These operation values were obtained in an anechoic room.
2) Sound pressure level will vary depending on a range of factors such as the construction of the particular room
3) Operation sound level may differ depending on operation and ambient conditions.
NC curve
1) AM240KXVAGH/EU 2) AM260KXVAGH/EU
75 75
70 Cooling 70 Cooling
65 65
NC 65 NC 65
60 60
NC 60 NC 60
Sound pressure level(dB)
55 55
NC 55 NC 55
50 50
NC 50 NC 50
45 45
NC 45 NC 45
40 40
NC 40 NC 40
35 35
NC 35 NC 35
30 30
NC 30 NC 30
25 25
NC 25 NC 25
20 20
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz) Octave band center frequency(Hz)
3) AM280KXVAGH/EU 4) AM300KXVAGH/EU
75 75
Cooling
Cooling
70 70
65 65
NC 65 NC 65
60 60
NC 60 NC 60
Sound pressure level(dB)
55 55
NC 55 NC 55
50 50
NC 50 NC 50
45 45
NC 45 NC 45
40 40
NC 40 NC 40
35 35
NC 35 NC 35
30 30
NC 30 NC 30
25 25
NC 25 NC 25
20 20
63 125 250 500 1000 2000 4000 8000 63 125 250 500 1000 2000 4000 8000
Octave band center frequency(Hz) Octave band center frequency(Hz)
7 Sound power level
Outdoor
Unit: dB(A)
Note
Model Power
* Specifications may be subject to change
1) dBA = A-weighted sound power level. AM080JXVAGH/EU 77
2) Reference power : 1pW. AM100JXVAGH/EU 79
3) Measured according to ISO 3741.
AM120JXVAGH/EU 81
AM140KXVAGH/EU 81
1)AM080JXVAGH/EU 2)AM100JXVAGH/EU
110 110
100 100
90 90
80 80
Sound power level(dB)
60 60
50 50
40 40
30 30
20 20
10 10
0 0
125 250 500 1000 2000 4000 8000 A 125 250 500 1000 2000 4000 8000 A
Octave band center frequency(Hz) Octave band center frequency(Hz)
3)AM120JXVAGH/EU 4)AM140KXVAGH/EU
110 110
100 100
90 90
80 80
Sound power level(dB)
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
125 250 500 1000 2000 4000 8000 A 125 250 500 1000 2000 4000 8000 A
Octave band center frequency(Hz) Octave band center frequency(Hz)
7 Sound power level
Outdoor
Unit: dB(A)
Note
Model Power
* Specifications may be subject to change
1) dBA = A-weighted sound power level. AM160KXVAGH/EU 83
2) Reference power : 1pW. AM180KXVAGH/EU 84
3) Measured according to ISO 3741.
AM200KXVAGH/EU 87
AM220KXVAGH/EU 89
1)AM160KXVAGH/EU 2)AM180KXVAGH/EU
110 110
100 100
90 90
80 80
Sound power level(dB)
60 60
50 50
40 40
30 30
20 20
10 10
0 0
125 250 500 1000 2000 4000 8000 A 125 250 500 1000 2000 4000 8000 A
Octave band center frequency(Hz) Octave band center frequency(Hz)
3)AM200KXVAGH/EU 4)AM220KXVAGH/EU
110 110
100 100
90 90
80 80
Sound power level(dB)
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
125 250 500 1000 2000 4000 8000 A 125 250 500 1000 2000 4000 8000 A
Octave band center frequency(Hz) Octave band center frequency(Hz)
7 Sound power level
Outdoor
Unit: dB(A)
Note
Model Power
* Specifications may be subject to change
1) dBA = A-weighted sound power level. AM240KXVAGH/EU 89
2) Reference power : 1pW. AM260KXVAGH/EU 89
3) Measured according to ISO 3741.
AM280KXVAGH/EU 90
AM300KXVAGH/EU 90
1)AM240KXVAGH/EU 2)AM260KXVAGH/EU
110 110
100 100
90 90
80 80
Sound power level(dB)
60 60
50 50
40 40
30 30
20 20
10 10
0 0
125 250 500 1000 2000 4000 8000 A 125 250 500 1000 2000 4000 8000 A
Octave band center frequency(Hz) Octave band center frequency(Hz)
3)AM280KXVAGH/EU 4)AM300KXVAGH/EU
110 110
100 100
90 90
80 80
Sound power level(dB)
70 70
60 60
50 50
40 40
30 30
20 20
10 10
0 0
125 250 500 1000 2000 4000 8000 A 125 250 500 1000 2000 4000 8000 A
Octave band center frequency(Hz) Octave band center frequency(Hz)
8 Cycle diagram
Outdoor
AM080JXVAGH/EU, AM100JXVAGH/EU, AM120JXVAGH/EU
SV_G
OFM T_A
T_CO
OHX
V_4W E_M
E
LPS CV_E
HPS T_S
V_EB
CV_D
s T_EO IC
HPSW
T_EI
V_HG
s
E_EV
E
OS
T_D
T_CT
AC IPMC
INV
T_L
SV_L
V_AR
s
V_ES
SV_G
OFM T_A
T_CO
OHX
CV_E E_M
E
V_4W
LPS
HPS T_S
IPMC IPMC
CV_D CV_D
s
HPSW HPSW V_HG IC
OS OS
V_EB T_EI
s T_EO
E_EV
E
T_D T_D
T_CT T_CT
AC
INV INV
T_L
SV_L
V_AR1
s
V_ES V_ES
CV_E1 SV_G
T_A
OFM
E
OHX
E_M1
E
T_CI E_M2
T_CO
CV_E2
V_4W
LPS
HPS
IPMC1 IPMC2
CVD1 CVD2
T_S
s
V_HG
OS1 OS2 IC
T_EI
V_EB
s T_EO E_EV
E
HPSW1 HPSW2
T_D1 T_D2
T_CT1 T_CT2
INV1 INV2 AC
T_L
SV_L
V_AR1
s
V_ES V_ES
CV_E1 SV_G
T_A
OFM RE
3.0L E
OHX
E_M1
E
T_CI E_M2
T_CO
CV_E2
V_4W
LPS
HPS
IPMC1 IPMC2
CVD1 CVD2
T_S
s
V_HG
OS1 OS2 IC
T_EI
V_EB
s T_EO E_EV
E
HPSW1 HPSW2
T_D1 T_D2
T_CT1 T_CT2
INV1 INV2 AC
T_L
SV_L
V_AR1
s
V_ES V_ES