0% found this document useful (0 votes)
39 views

VMAX3 CSQRG

The document is a Customer Service Quick Reference Guide for the Dell EMC VMAX3 Family (VMAX 100K, 200K, 400K) version 5.0, published in March 2019. It includes detailed information on system layout, engine components, I/O modules, storage components, power components, and part numbers. The guide is intended for customer service representatives to assist with the setup and maintenance of the VMAX systems.

Uploaded by

tachyon.20230417
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
39 views

VMAX3 CSQRG

The document is a Customer Service Quick Reference Guide for the Dell EMC VMAX3 Family (VMAX 100K, 200K, 400K) version 5.0, published in March 2019. It includes detailed information on system layout, engine components, I/O modules, storage components, power components, and part numbers. The guide is intended for customer service representatives to assist with the setup and maintenance of the VMAX systems.

Uploaded by

tachyon.20230417
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 86

DELL EMC CONFIDENTIAL

Dell EMC VMAX3 Family


VMAX 100K, 200K, 400K
Version 5.0

Customer Service Quick Reference Guide


DELL EMC CONFIDENTIAL
Copyright © 2015-2019 Dell Inc. or its subsidiaries. All rights reserved.

Published March 2019

Dell believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS-IS.“ DELL MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND
WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED
IN THIS PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE.

Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners.
Published in the USA.

Dell EMC
Hopkinton, Massachusetts 01748-9103
1-508-435-1000 In North America 1-866-464-7381
www.DellEMC.com

2 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CONTENTS

Figures 5

Tables 7

Revision history 9

Chapter 1 System Bay Stack-Up 11


Single engine, system bay 1.........................................................................12
Single engine, system bays 2-8................................................................... 13
Dual engine, system bay 1............................................................................14
Dual engine, system bays 2-4......................................................................15
Lightbar cabling - single engine, system bay 1............................................. 16
Lightbar cabling - single engine, system bays 2-8....................................... 17
Lightbar cabling - dual engine, system bay 1................................................18
Lightbar cabling - dual engine, system bays 2-4..........................................19

Chapter 2 System layout 21


Single engine, adjacent bays.......................................................................22
Single engine, dispersed bays..................................................................... 23
Single engine, dispersed and adjacent (mixed) bays................................... 24
Dual engine, adjacent bays......................................................................... 25
Dual engine, dispersed bays........................................................................26
Dual engine, dispersed and adjacent (mixed) bays...................................... 27

Chapter 3 Engine Components 29


Engine components ................................................................................... 30
Engine director .......................................................................................... 32
Engine physical port numbering..................................................................33
Engine logical port numbering.....................................................................34
MIBE - 12-port............................................................................................35
MIBE - 18-port............................................................................................36
Ethernet switch.......................................................................................... 37
MMCS diagram.......................................................................................... 38
Management Module (MM) diagram.......................................................... 39
Front-end I/O module: 4/8 Gb/s Fibre Channel, SRDF, eNAS................... 40
Front-end I/O module: 16 Gb/s Fibre Channel, SRDF................................. 41
Front-end I/O module: 10 GbE SRDF..........................................................42
Front-end I/O module: 1 GbE SRDF............................................................43
Front-end I/O module: 10 GigE (optical) eNAS...........................................44
Front-end I/O module: 10 GigE (copper) eNAS.......................................... 45
Front end I/O module: 1 GigE eNAS........................................................... 46
Front end I/O module: Mixed Fibre Channel and Ethernet SRDF................ 47

Chapter 4 I/O Modules 49


Vault flash - slots 0, 1 and 6, 7.................................................................... 50
Fabric - slot 10............................................................................................ 51

VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide 3
DELL EMC CONFIDENTIAL
CONTENTS

SAS back end - slots 4, 5............................................................................52


Front end connectivity - slots 2, 3 and 8, 9................................................ 53

Chapter 5 Storage Components 55


60-drive DAE..............................................................................................56
60-drive DAE layout and power distribution............................................... 58
120-drive DAE............................................................................................ 59
120-drive DAE layout and power distribution.............................................. 60
SAS cabling, single-engine.......................................................................... 61
SAS cabling, dual-engine............................................................................ 62

Chapter 6 Power Components 65


PDU, three-phase.......................................................................................66
PDU cabling, three-phase, single-engine, system bay 1 ................ 67
PDU cabling, three-phase, single-engine, system bays 2-8 ...........68
PDU cabling, three-phase, dual-engine, system bay 1 ...................69
PDU cabling, three-phase, dual-engine, system bays 2-4.............. 70
PDU, single-phase....................................................................................... 71
PDU cabling, single-phase, single-engine, system bay 1................. 72
PDU cabling, single-phase, single-engine, system bays 2-8 .......... 73
PDU cabling, single-phase, dual-engine, system bay 1 .................. 74
PDU cabling, single-phase, dual-engine, system bays 2-4..............75

Chapter 7 Part Numbers 77


System bay part numbers .......................................................................... 78
Engine component part numbers................................................................ 78
DAE part numbers...................................................................................... 80
3.5 inch drive part numbers.........................................................................81
2.5 inch drive part numbers.........................................................................81
3rd party part numbers...............................................................................82
Cable part numbers.................................................................................... 82

4 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

FIGURES

1 Single engine, system bay 1......................................................................................... 12


2 Single engine, system bays 2-8................................................................................... 13
3 Dual engine, system bay 1............................................................................................14
4 Dual engine, system bays 2-4......................................................................................15
5 Lightbar cabling - single engine, system bay 1............................................................. 16
6 Lightbar cabling - single engine, system bays 2-8........................................................17
7 Lightbar cabling - dual engine, system bay 1................................................................18
8 Lightbar cabling - dual engine, system bays 2-4.......................................................... 19
9 Single engine, adjacent bays.......................................................................................22
10 Single engine, dispersed bays..................................................................................... 23
11 Single engine, dispersed and adjacent (mixed) bays................................................... 24
12 Dual engine, adjacent bays......................................................................................... 25
13 Dual engine, dispersed bays........................................................................................26
14 Dual engine, dispersed and adjacent (mixed) bays...................................................... 27
15 Engine components.................................................................................................... 30
16 Engine director .......................................................................................................... 32
17 Engine physical port numbering.................................................................................. 33
18 Engine logical port numbering.....................................................................................34
19 MIBE - 12-port............................................................................................................35
20 MIBE - 18-port............................................................................................................36
21 Ethernet switch.......................................................................................................... 37
22 MMCS diagram.......................................................................................................... 38
23 Management Module (MM) diagram.......................................................................... 39
24 Front-end I/O module: 4/8 Gb/s Fibre Channel, SRDF, eNAS................................... 40
25 Front-end I/O module: 16 Gb/s Fibre Channel, SRDF................................................. 41
26 Front-end I/O module: 10 GbE SRDF..........................................................................42
27 Front-end I/O module: 1 GbE SRDF............................................................................43
28 Front-end I/O module: 10 GigE (optical) eNAS...........................................................44
29 Front-end I/O module: 10 GigE (copper) eNAS.......................................................... 45
30 Front end I/O module: 1 GigE eNAS............................................................................46
31 Front end I/O module: Mixed Fibre Channel and Ethernet SRDF................................ 47
32 Engine rear view - vault flash..................................................................................... 50
33 Engine rear view - fabric............................................................................................. 51
34 Engine rear view - SAS back end................................................................................ 52
35 Engine rear view - front end connectivity................................................................... 53
36 60-drive DAE..............................................................................................................56
37 60-drive DAE layout and power distribution............................................................... 58
38 120-drive DAE............................................................................................................ 59
39 120-drive DAE layout and power distribution.............................................................. 60
40 SAS cabling, single-engine.......................................................................................... 61
41 SAS cabling, dual-engine............................................................................................ 62
42 PDU, three-phase.......................................................................................................66
43 PDU cabling, three-phase, single-engine, system bay 1 ............................................. 67
44 PDU cabling, three-phase, single-engine, system bays 2-8 ....................................... 68
45 PDU cabling, three-phase, dual-engine, system bay 1 ................................................69
46 PDU cabling, three-phase, dual-engine, system bays 2-4........................................... 70
47 PDU, single-phase....................................................................................................... 71
48 PDU cabling, single-phase, single-engine, system bay 1..............................................72
49 PDU cabling, single-phase, single-engine, system bays 2-8 ....................................... 73
50 PDU cabling, single-phase, dual-engine, system bay 1 ............................................... 74
51 PDU cabling, single-phase, dual-engine, system bays 2-4...........................................75

VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide 5
DELL EMC CONFIDENTIAL
FIGURES

6 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

TABLES

1 Adjacent layout diagram key....................................................................................... 22


2 Adjacent layout diagram key.......................................................................................25
3 Vault flash.................................................................................................................. 50
4 Fabric..........................................................................................................................51
5 SAS back end ............................................................................................................ 52
6 Host connectivity - Fibre Channel and SRDF..............................................................53
7 Host connectivity - GigE iSCSI and SRDF.................................................................. 54
8 eNAS connectivity......................................................................................................54

VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide 7
DELL EMC CONFIDENTIAL
TABLES

8 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

Revision history

Revision Description Date released


5.0 Updated SPS battery part March, 2019
number.

4.0 Corrected port description for September, 2018


1 GbE SRDF front-end I/O
module.

3.0 Added SlicMap and DirMap June, 2017


mappings for I/O modules.

2.0 Updated text and graphics for May, 2017


accuracy.

1.6 Removed 3 and 4 engine October, 2016


option for 100K.

1.5 l Removed loop locations July, 2016


layout
l Removed "system input
power conversion part
numbers" from parts list
l Added labels to 120-drive
DAE diagram
l Added "where used"
column to power cables
table in parts list

1.4 Updated MMCS Port Map: November, 2015


l Changed label "black,
CUST" to "black, Guest
OS, CUST"
l Changed color of
Network Ethernet Cable
to a lighter blue.

1.3 l Added new 10Gb front September, 2015


end module
l Updated single engine
system layout
l Updated I/O module
population order
configuration details:
change Flash Module
capacities from TB to GB.

1.2 l Updated MMCS port map April, 2015

Revision history 9
DELL EMC CONFIDENTIAL
Revision history

Revision Description Date released

l Added Network Ethernet


dongle (038-003-718) to
parts list

1.1 Minor updates March, 2015

1.0 Initial release February, 2015

10 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 1
System Bay Stack-Up

Topics include:

l Single engine, system bay 1................................................................................ 12


l Single engine, system bays 2-8...........................................................................13
l Dual engine, system bay 1................................................................................... 14
l Dual engine, system bays 2-4............................................................................. 15
l Lightbar cabling - single engine, system bay 1.....................................................16
l Lightbar cabling - single engine, system bays 2-8............................................... 17
l Lightbar cabling - dual engine, system bay 1....................................................... 18
l Lightbar cabling - dual engine, system bays 2-4................................................. 19

System Bay Stack-Up 11


DELL EMC CONFIDENTIAL
System Bay Stack-Up

Single engine, system bay 1


Figure 1 Single engine, system bay 1

18-Port MIBE 18-Port MIBE


400K SPS 3A/B #1 400K
OK OK OK OK

MIBE B
MGT
Mellanox R

CONSOLE
Mellanox
TECHNOLOGIES
R
MGT TECHNOLOGIES

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
OK OK OK Mellanox
OK CONSOLE
R

TECHNOLOGIES

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PS1
PS2

#2,#3
UID
OK OK OK OK PS1 RST
Mellanox
TECHNOLOGIES
R

PS2 MGT
Mellanox R

TECHNOLOGIES CONSOLE
Mellanox
TECHNOLOGIES
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
UID
PS1
RST
PS2

MIBE A
UID
MGT RST
Mellanox
CONSOLE
R

OK OK OK OK TECHNOLOGIES

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

PS1
Mellanox R

TECHNOLOGIES
PS2

UID
RST

12-Port MIBE 12-Port MIBE


100K or 200K 100K or 200K
PS1
1 2 3 4 5 6 7 8 9 10 11 12
PS2

SAS
2
UID

RST

Mellanox R

PS1
1 2 3 4 5 6 7 8 9 10 11 12
PS2

UID

RST

1
Mellanox R

0
2 SAS

Engine 1 A

1
0
1

6
3

6
2

5
PDU #4,#5,#6

4
4

3
5

2
6

3
6

1
DC

AC
120 drive DAE
(DAE 6)
Ethernet switch #7 eco
friendly
Allied Telesis

L/A

D/A

L/A

D/A

POWER 2 4 6
AT-GS900/16
16 Port 10/100/1000Base-T Gigabit Ethernet Switch

1 3 5 7

8
9 11 13 15

10 12 14 16
1

2
L/A

4
1000 LINK

6
ACT 10/100 LINK

8
ACT

10
D/A FDX

11

12
HDX

13

14
COL

15

16
eco
friendly
Allied Telesis

L/A

D/A

L/A

D/A

POWER
1

2
3

4
5

6
AT-GS900/16
16 Port 10/100/1000Base-T Gigabit Ethernet Switch

8
9 11 13 15

10 12 14 16
1

2
L/A

4
1000 LINK

6
ACT 10/100 LINK

8
ACT

10
D/A FDX

11

12
HDX COL

13

14
15

16

KVM #8
DC

AC

120 drive DAE


(DAE 5)

60 drive DAE
(DAE 4) 0 1 0 1

60 drive DAE
(DAE 3) 0 1 0 1

DC DC DC DC

120 drive DAE


AC AC AC AC

(DAE 2)

120 drive DAE


DC DC DC DC

AC AC AC AC

(DAE 1)
SPS 1A/B

Front view Rear view

Part number information about components #1 - #8 is available at System bay part


numbers on page 78.

Part number information about DAEs is available at DAE part numbers on page
80.
Configuration Details
l Each system bay 1 contains a PDU, KVM, Ethernet switch and up to six DAEs, and
1 or 2 SPS pairs. The configuration depends on whether there are one or two
engines in the system.
l Multiple engine systems include a 12-port (VMAX 100K and 200K) or 18-port
(VMAX 400K) MIBE.
l Systems can use 60-drive (3.5" form factor) DAEs or 120-drive (2.5" form factor)
DAEs. 2.5" and 3.5" DAEs can be mixed behind an engine.

12 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System Bay Stack-Up

Single engine, system bays 2-8


Figure 2 Single engine, system bays 2-8

SPS 3A/B #1

SAS
2

1
B

0
2 SAS

Engine A

1
0
1

6
3

6
#4,#5,#6

5
PDU

4
4

3
5

2
6

3
6

1
DC DC DC DC

AC AC AC AC

120 drive DAE


(DAE 6)
Worktray
DC DC DC DC

AC AC

120 drive DAE


AC AC

(DAE 5)

60 drive DAE
(DAE 4) 0 1 0 1

60 drive DAE
(DAE 3) 0 1 0 1

DC DC DC DC

AC AC AC AC

120 drive DAE


(DAE 2)
DC DC DC DC

120 drive DAE


AC AC AC AC

(DAE 1)

Front view Rear view

Part number information about components #1 and #4 - #6 is available at System


bay part numbers on page 78.

Part number information about DAEs is available at DAE part numbers on page
80.
Configuration Details
l System bays 2 through 8 on single engine systems include a work tray, and do not
include a MIBE, supporting SPS (1A/B), Ethernet switch or KVM.
l Single engine system bays can contain any mix of up to six 60-drive or 120-drive
DAEs.

Single engine, system bays 2-8 13


DELL EMC CONFIDENTIAL
System Bay Stack-Up

Dual engine, system bay 1


Figure 3 Dual engine, system bay 1

18-Port MIBE 18-Port MIBE


400K SPS 3A/B #1 400K
OK OK OK OK

MGT

MIBE B
Mellanox R

Mellanox R TECHNOLOGIES CONSOLE


TECHNOLOGIES
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

PS1
1 2 3 4 5 6 7 8 9 10 11 12 PS1
PS2

PS2 UID

#2,#3
OK OK OK OK
RST

UID MGT
Mellanox R

TECHNOLOGIES CONSOLE
Mellanox
TECHNOLOGIES
R

RST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

PS1
Mellanox R

PS2

UID
RST

1 2 3 4 5 6 7 8 9 10 11 12

MIBE A
PS1
PS2

UID

RST

Mellanox R

12-Port MIBE 12-Port MIBE


100K or 200K 100K or 200K
PS1
1 2 3 4 5 6 7 8 9 10 11 12
SAS
2 PS2

UID

RST

Mellanox R

PS1
1 2 3 4 5 6 7 8 9 10 11 12
PS2

1
UID

RST

B Mellanox R

0
2 SAS

Engine 1 A

1
0
1

6
3

6
#4,#5,#6

5
PDU

4
4

3
5

2
6

3
6

1
SAS
2

1
B

0
2 SAS

Engine 2 A

1
0
Ethernet switch #7 eco
friendly
Allied Telesis

L/A

D/A

L/A

D/A

POWER 2 4 6
AT-GS900/16
16 Port 10/100/1000Base-T Gigabit Ethernet Switch

1 3 5 7

8
9 11 13 15

10 12 14 16
1

2
L/A

4
1000 LINK

6
ACT 10/100 LINK

8
ACT

10
D/A FDX

11

12
HDX COL

13

14
15

16
eco
friendly
Allied Telesis

L/A

D/A

L/A

D/A

POWER
1

2
3

4
5

6
AT-GS900/16
16 Port 10/100/1000Base-T Gigabit Ethernet Switch

8
9 11 13 15

10 12 14 16
1

2
L/A

4
1000 LINK

6
ACT 10/100 LINK

8
ACT

10
D/A FDX

11

12
HDX COL

13

14
15

16

KVM #8

SPS 2A/B #1

60 drive DAE
(DAE 4) 0 1 0 1

60 drive DAE
(DAE 3) 0 1 0 1

DC DC DC DC

AC AC AC AC

120 drive DAE


(DAE 2)

120 drive DAE


DC DC DC DC

AC AC AC AC

(DAE 1)
SPS 1A/B

Front view Rear view

Part number information about components #1 - #8 is available at System bay part


numbers on page 78.

Part number information about DAEs is available at DAE part numbers on page
80.
Configuration Details
l System bay 1 on dual-engine systems includes engine 1 (upper) and engine 2
(lower) as well as an Ethernet switch and KVM.
l Systems loaded with more than one engine include a MIBE.
l Dual-engine systems can contain any mix of up to four 60- or 120-drive DAEs
within the system bay.

14 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System Bay Stack-Up

Dual engine, system bays 2-4


Figure 4 Dual engine, system bays 2-4

SPS 3A/B #1

2 SAS

01 01
B
2 SAS Engine - Odd A

6
3

6
2

5
PDU #4,#5,#6

4
4

3
5

2
6

3
2 SAS

01 01
B
2 SAS Engine - Even A

Worktray

SPS 2A/B #1

60 drive DAE
(DAE 4) 0 1 0 1

60 drive DAE
(DAE 3) 0 1 0 1

DC DC DC DC

AC AC AC AC

120 drive DAE


(DAE 2)

120 drive DAE


DC DC DC DC

AC AC AC AC

(DAE 1)

Front view Rear view

Part number information about components #1 and #4 - #6 is available at System


bay part numbers on page 78.

Part number information about DAEs is available at DAE part numbers on page
80.
Configuration Details
l System bays 2 through 4 on dual engine systems provide an odd engine (upper)
and even engine (lower).
l A work tray is provided in place of the KVM.
l The MIBE and Ethernet switch are not included.
l Dual engine system bays 2 - 4 contain any mix of up to four 60- or 120-drive DAEs.
l A single bay may be added for each dual engine system bay.

Dual engine, system bays 2-4 15


DELL EMC CONFIDENTIAL
System Bay Stack-Up

Lightbar cabling - single engine, system bay 1


Figure 5 Lightbar cabling - single engine, system bay 1

16 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System Bay Stack-Up

Lightbar cabling - single engine, system bays 2-8


Figure 6 Lightbar cabling - single engine, system bays 2-8

Lightbar cabling - single engine, system bays 2-8 17


DELL EMC CONFIDENTIAL
System Bay Stack-Up

Lightbar cabling - dual engine, system bay 1


The following diagram illustrates lightbar cabling in an EMC rack. Lightbar cabling for
third-party racks is covered in the third-party rack installation guides.
Figure 7 Lightbar cabling - dual engine, system bay 1

18 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System Bay Stack-Up

Lightbar cabling - dual engine, system bays 2-4


The following diagram illustrates lightbar cabling in an EMC rack. Lightbar cabling for
third-party racks is covered in the third-party rack installation guides.
Figure 8 Lightbar cabling - dual engine, system bays 2-4

Lightbar cabling - dual engine, system bays 2-4 19


DELL EMC CONFIDENTIAL
System Bay Stack-Up

20 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 2
System layout

Topics include:

l Single engine, adjacent bays.............................................................................. 22


l Single engine, dispersed bays.............................................................................23
l Single engine, dispersed and adjacent (mixed) bays...........................................24
l Dual engine, adjacent bays................................................................................. 25
l Dual engine, dispersed bays............................................................................... 26
l Dual engine, dispersed and adjacent (mixed) bays............................................. 27

System layout 21
DELL EMC CONFIDENTIAL
System layout

Single engine, adjacent bays


Figure 9 Single engine, adjacent bays

1 2 3

System System System System System System System System


bay 1 bay 2 bay 3 bay 4 bay 5 bay 6 bay 7 bay 8
Engine 1 Engine 2 Engine 3 Engine 4 Engine 5 Engine 6 Engine 7 Engine 8

00 R1 R2 R3 R4 R5 R6 R7

Bay position

Table 1 Adjacent layout diagram key

# Description
1 VMAX 100K

2 VMAX 200K

3 VMAX 400K

Configuration Details
Single-engine systems in adjacent layouts are arranged in a single row.
Models are defined by the number of engines:
l 100K - up to 2 engines (2 system bays)
l 200K - up to 4 engines (4 system bays
l 400K - up to 8 engines (8 system bays)
Directors are numbered from bottom to top, beginning with engine 1.

22 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System layout

Single engine, dispersed bays


Figure 10 Single engine, dispersed bays

System System System System System


bay 3 bay 4 bay 5 bay 6 bay 7
Engine 3 Engine 4 Engine 5 Engine 6 Engine 7

System
System
bay 1 System
bay 2
Engine 1
bay 8
Engine 2
Engine 8

Maximum dispersion is 82 feet (25 meters) from system bay 1.

Single engine, dispersed bays 23


DELL EMC CONFIDENTIAL
System layout

Single engine, dispersed and adjacent (mixed) bays


Figure 11 Single engine, dispersed and adjacent (mixed) bays

Initial
install
System
bay 3
Engine 3

Initial
install Upgrade

System System System


bay 1 bay 2 bay 4
Engine 1 Engine 2 Engine 4

00 R1 R2

Bay position

Maximum dispersion is 82 feet (25 meters) from system bay 1.

24 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System layout

Dual engine, adjacent bays


Dual-engine systems with adjacent layouts position system bay 1 next to system bay 2,
and system bay 3 next to system bay 4.
Figure 12 Dual engine, adjacent bays

3
2
1

System System System System


bay 1 bay 2 bay 3 bay 4

Engine 1 Engine 3 Engine 5 Engine 7


Engine 6 Engine 8
Engine 2 Engine 4

00 R1 R2 R3

Bay position

Table 2 Adjacent layout diagram key

# Description
1 VMAX 100K

2 VMAX 200K

3 VMAX 400K

Dual engine, adjacent bays 25


DELL EMC CONFIDENTIAL
System layout

Dual engine, dispersed bays


Figure 13 Dual engine, dispersed bays

System
Bay 3
Engine 5
Engine 6

System System
Bay 2 Bay 4
Engine 3
Engine 7
Engine 4
System Engine 8
Bay 1
bay
Engine 1
Engine 2

Maximum dispersion is 82 feet (25 meters) from system bay 1.

26 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
System layout

Dual engine, dispersed and adjacent (mixed) bays


Figure 14 Dual engine, dispersed and adjacent (mixed) bays

System
bay 2
Engine 3
Engine 4

Initial
install

System System
bay 1 bay 3
Engine 1 Engine 5
Engine 2 Engine 6

00 R1

Bay position

Maximum dispersion is 82 feet (25 meters) from system bay 1.

Dual engine, dispersed and adjacent (mixed) bays 27


DELL EMC CONFIDENTIAL
System layout

28 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 3
Engine Components

Topics include:

l Engine components ...........................................................................................30


l Engine director ..................................................................................................32
l Engine physical port numbering......................................................................... 33
l Engine logical port numbering............................................................................ 34
l MIBE - 12-port................................................................................................... 35
l MIBE - 18-port................................................................................................... 36
l Ethernet switch..................................................................................................37
l MMCS diagram.................................................................................................. 38
l Management Module (MM) diagram..................................................................39
l Front-end I/O module: 4/8 Gb/s Fibre Channel, SRDF, eNAS........................... 40
l Front-end I/O module: 16 Gb/s Fibre Channel, SRDF......................................... 41
l Front-end I/O module: 10 GbE SRDF................................................................. 42
l Front-end I/O module: 1 GbE SRDF................................................................... 43
l Front-end I/O module: 10 GigE (optical) eNAS.................................................. 44
l Front-end I/O module: 10 GigE (copper) eNAS..................................................45
l Front end I/O module: 1 GigE eNAS................................................................... 46
l Front end I/O module: Mixed Fibre Channel and Ethernet SRDF........................47

Engine Components 29
DELL EMC CONFIDENTIAL
Engine Components

Engine components
Figure 15 Engine components

Empty boot drive


slots in engine
Front
Boot drive SAS

Power supply B1 - Zone B P/S B Even Director

Power supply A1 - Zone A P/S A Even Director

Boot drive
SAS

Power supply B0 - Zone B P/S B Odd Director

Power supply A0 - Zone A P/S A Odd Director

#16,#17
Fan 0 Fan 1 Fan 2 Fan 3 Fan 4
#18
Rear
Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10

Power Zone B
Even Director
Power Zone A #13,#14,#15
AC Tube
#50
Power Zone B Odd Director
Power Zone A

Front-end Front-end
I/O modules Vault I/O modules
MMCS (Eng 1 only) Vault SAS Flash #26-#34
#9,#10 Flash Back End SIB (multiple engine systems only)
#11,#12 #20
MM (Eng 2-8) #35
#19

Part number information about components #9-#20, #26-#35 and #50 is available
at Engine component part numbers on page 78.
Configuration Details
l Engines consist of two directors, odd (lower) and even (upper).
l The engine front includes fans and power supplies.
l Drive 0, at the top of each director, is used for director boot and code loads.
l The engine rear provides 11 I/O slots, populated as follows:
n Slots 0, 1, 6 and 7 - Vault-to-flash

30 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

n Slot 2, 3, 8, 9 - Universal front-End I/O


n Slots 4 and 5 - SAS Back end
n Slot 10 - SIB if MIBE installed

Engine components 31
DELL EMC CONFIDENTIAL
Engine Components

Engine director
Figure 16 Engine director

Engine director

Boot Memory modules


disk #21-#25
15 14 13 12 11 10 9 8

Front view

Fans
#18

Power supplies
#16,#17

7 6 5 4 3 2 1 0
Memory module locations
Front view

Part number information about components #16 - #18 and #21 - #25 is available at
Engine component part numbers on page 78.

Part number information about disks is available at 2.5 inch drive part numbers on
page 81 and 3.5 inch drive part numbers on page 81.
Configuration Details
l 2 directors per engine, each director has redundant power and cooling
l 7 I/O slots/director
n 1 Fabric connect
n 2 BE to drives

32 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

n Up to 8 vault to flash
n Up to 4 shared for FE and compression
l Cache memory per engine (2 directors) by model:
n VMAX 100K - 512 GB or 1TB
n VMAX 200K, VMAX 400K - 512 GB, 1 TB, 2 TB

Engine physical port numbering


Figure 17 Engine physical port numbering

Slot 10
Slot 0

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9
3 3 3 3 3 3
2 2 2 2 2 2 1
Director
1 1 1 1 1 1 0 EVEN
0 8 0 0 0 0

3 3 3 3 3 3
2 2 2 2 2 2 1 Director
1 1 1 1 1 1 ODD
0
0 0 0 0 0 0
Vault to flash
Module or MMCS

Universal/FE

Fabric
Vault to flash

Universal/FE

Back End
Managament

Configuration Details
l I/O module slots numbered 0 - 10 from left to right
l Ports numbered 0 - 3 from bottom to top of each I/O module
l I/O modules with 2 ports numbered 0 & 1 bottom to top

Note

All slots have four logical ports. For two port modules, physically ports are 0 and 1 and
logically only two of the four ports are used. The other two are designated but unused.

Engine physical port numbering 33


DELL EMC CONFIDENTIAL
Engine Components

Engine logical port numbering


Figure 18 Engine logical port numbering

Slot 10
Slot 0

Slot 1

Slot 2

Slot 3

Slot 4

Slot 5

Slot 6

Slot 7

Slot 8

Slot 9
7 11 15 19 27 31

lash
6 10 14 18 26 30 1
5 9 13 17 25 29 Director
0 EVEN
4 8 12 16 24 28

7 11 15 19 27 31
6 10 14 18 26 30 1
Director
5 9 13 17 Vau 25 29 0 ODD

Vau
4 8 12 16 Vault to flash 24 28
Module or MMCS

Universal/FE

Fabric
Vault to flash

Universal/FE

Back End
Managament

Configuration Details
l Engine slots and ports are numbered from left to right, bottom to top, across the
slots that contain FE or BE I/O modules.
l Reserved for future use:
n Slot 1 - Ports 0,1,2,3
n Slot 7 - Ports 20,21,22,23
l All slots have four logical ports. For two port modules, physically ports are 0 and 1
and logically only two of the four ports are used. The other two are designated but
unused.

34 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

MIBE - 12-port
Figure 19 MIBE - 12-port

PS1
1 2 3 4 5 6 7 8 9 10 11 12

Rear
PS2

UID

RST

Mellanox
R

Director 7
Director 1
Director 3
Director 5
<--> To SIB, Port B

X = port not used


MIBE B
1 3 5 7 X9 X11 1

2 X
2
2 4 6 8 X
1
100 X
1
12
Director 8
Director 2
Director 4
Director 6

<--> To SIB, Port B


Director 1
Director 3

Director 7
Director 5

<--> To SIB, Port A

X = port not used

MIBE A
1 3 5 7 X9 X11 1

2 X
2
2 4 6 8 X
10
1 0 X
12
1
Director 8
Director 4
Director 2

Director 6

<--> To SIB, Port A

Part number information about the 12-port MIBE (#2) is available at System bay
part numbers on page 78.
Configuration Details
l VMAX 100K and VMAX 200K systems use the 12-port MIBE.
n VMAX 100K uses ports 1-4 for directors 1-4
n VMAX 200K can use ports 5-8 for directors 1-8
l Ports on the MIBE connect to the SIB on the corresponding director:
n MIBE A connects to SIB port A
n MIBE B connectics to SIB port B
l MIBE ports 9, 10, 11, and 12 are not used

MIBE - 12-port 35
DELL EMC CONFIDENTIAL
Engine Components

MIBE - 18-port
Figure 20 MIBE - 18-port
MGT
Mellanox
CONSOLE
R

TECHNOLOGIES

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18

Rear
PS1
PS2

UID
RST

Director 10

Director 12

Director 14

Director 16
Director 13
Director 11

Director 15
Director 2

Director 4

Director 6

Director 8
Director 1

Director 5

Director 9
Director 3

Director 7

<-> To SIB, Port B


MIBE B

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X 1X
17
17 8
18
1
X
X2 X
Director 10

Director 12

Director 14

Director 16
Director 11

Director 13

Director 15
Director 2

Director 4

Director 6

Director 8
Director 1

Director 5

Director 9
Director 3

Director 7

<-> To SIB, Port A


MIBE A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 X 18
17
17X8
1
1
X
X2 X
X = port not used

Part number information about the 18-port MIBE (#3) is available at System bay
part numbers on page 78.
Configuration Details
l VMAX 400K systems use the 18-port MIBE.
l Ports on the MIBE connect to the SIB on the corresponding director:
n SIB port A connects to MIBE A
n SIB port B connects to MIBE B
l MIBE ports 17 and 18 are not used.

36 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

Ethernet switch
Figure 21 Ethernet switch

Eng-1, MMCS-1
Eng-1, MMCS-1

MM-11
MM-15
MM-12
MM-16

MM-3
MM-7
MM-4
MM-8

Eng-2,

Eng-6,
Eng-8,
Eng-4,
Eng-2,

Eng-6,
Eng-8,
Eng-4,
Switch B Switch A
Allied Telesis AT-GS900/16 Allied Telesis AT-GS900/16 L/A 1000 LINK ACT 10/100 LINK ACT D/A FDX HDX COL
L/A 1000 LINK ACT 10/100 LINK ACT D/A FDX HDX COL
16 Port 10/100/1000Base-T Gigabit Ethernet Switch
16 Port 10/100/1000Base-T Gigabit Ethernet Switch
1 3 5 7 9 11 13 15 1 3 5 7 9 11 13 15
1 3 5 7 9 11 13 15 L/A 1 3 5 7 9 11 13 15
L/A

D/A
D/A
L/A
eco L/A eco
friendly
friendly D/A
D/A

2 4 6 8 10 12 14 16 POWER 2 4 6 8 10 12 14 16
POWER

2 4 6 8 10 12 14 16 2 4 6 8 10 12 14 16

Eng-1, MMCS-2

Eng-1, MMCS-2
MIBE-B, Port 1

MIBE-A, Port 1
Eng-5, MM-10
Eng-7, MM-14

Eng-7, MM-13
Eng-3, MM-6

Eng-3, MM-5
Eng-5, MM-9

CS Ethernet
Rear view

Part number information about Ethernet switch (#7) is available at System bay
part numbers on page 78.
Configuration Details
l MMCS and MM modules connect to the Ethernet switch on system bay 1.
l MMCS and MM cables are color coded:
n Violet cables connect to switch B
n Green cables connect to switch A
l Color coded labels on each cable identify the engine to which the cable connects.

Ethernet switch 37
DELL EMC CONFIDENTIAL
Engine Components

MMCS diagram
Figure 22 MMCS diagram

Director 2 (upper) MMCS 2 USB/CS code load*


039-004-110
yellow

violet, Fabric B 038-000-446-00 light gray


black, Guest OS, CUST 039-004-110
Keyed USB to KVM
connector
green, Fabric A mouse/keyboard*

038-004-127-00
KVM
VGA*
To SPS 1A
To Modem
039-000-021 Group and dress*
pink
To SPS 3B

Engine 1
Network
Ethernet port 038-003-718

Director 1 (lower) MMCS 1


039-004-110
yellow
USB/CS code load
violet, Fabric B 038-000-446-00 light gray (cable routed to front)
black, Guest OS, CUST 039-004-110
Keyed
connector USB to KVM
green, Fabric A mouse/keyboard
To front door light bar 039-004-113
USB 038-004-127-00
cyan
To SPS 1B KVM
To Modem VGA
039-000-021
pink
To SPS 3A
Network
Ethernet port 038-003-718

Configuration Details
l Group the unconnected cables from MMCS-2 together and dress to the cable
retention bar (or similar structure) at the top of the cabinet.
l In MMCS-1, the yellow USB/CS code load cable is routed to the front.
l LEDs: power and marker.

38 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

Management Module (MM) diagram


Figure 23 Management Module (MM) diagram

Director even (upper)


Management Module - even

Dress*
Service port,
worktray*
Ethernet switch B
038-004-136

To SPS
038-004-283
Engine

Director odd (lower)


Management Module - odd

Service port, worktray


038-004-136
Ethernet switch A

To front door light bar


038-003-941
USB

To SPS
038-004-283

Configuration Details
l Group the unconnected cables from MM (even/upper) and dress to the cable
retention bar (or similar structure) at the top of the cabinet.
l 2x Ethernet connections for Mgmt and Service LAN.
l 2x Serial Port in micro DB9 connector for SPS.

Management Module (MM) diagram 39


DELL EMC CONFIDENTIAL
Engine Components

Front-end I/O module: 4/8 Gb/s Fibre Channel, SRDF,


eNAS
Figure 24 Front-end I/O module: 4/8 Gb/s Fibre Channel, SRDF, eNAS

0 1 2 3
SYM-002855

3
2
1
0

SYM-002856

#26 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Quad Port 8G Fibre Channel interface
l Copper (4G) and optical (8G) media via SFP+ connector

40 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

Front-end I/O module: 16 Gb/s Fibre Channel, SRDF


Figure 25 Front-end I/O module: 16 Gb/s Fibre Channel, SRDF

SFP+ SM module (16 Gb Fibre)

0 1 2 3

SFP+ SM module (4/8 Gb Fibre)

SFP+ MM module (4/8 Gb Fibre)


0

1
bre
b Fi
4G
2
3
3

Fibre Channel 4-port options


(4/8 Gb)

MM MM MM MM SM SM SM SM MM MM SM MM SM MM SM MM
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

4 MM ports 4 SM ports 3 MM, 1 SM ports 2 MM, 2 SM ports

#33 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Quad Port Fibre Channel interface
l Optical media via SFP+ connector

Front-end I/O module: 16 Gb/s Fibre Channel, SRDF 41


DELL EMC CONFIDENTIAL
Engine Components

Front-end I/O module: 10 GbE SRDF


Figure 26 Front-end I/O module: 10 GbE SRDF

0 1
SYM-002857

0 SYM-002858

#32 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Dual port 10GbE
l Copper and optical media via SFP+ connector

42 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

Front-end I/O module: 1 GbE SRDF


Figure 27 Front-end I/O module: 1 GbE SRDF

0 1 2 3
SYM-002877

3
2
1
0

SYM-002878

#29 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Quad port 1GbE interface
l 2 ports copper via RJ45 (ports 0, 1)
l 2 ports optical via SFP (ports 2, 3)

Front-end I/O module: 1 GbE SRDF 43


DELL EMC CONFIDENTIAL
Engine Components

Front-end I/O module: 10 GigE (optical) eNAS


Figure 28 Front-end I/O module: 10 GigE (optical) eNAS

0 1
SYM-002859

0
SYM-002860

#34 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Dual Port 10GbE interface
l Copper and optical media via SFP+ connector

44 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

Front-end I/O module: 10 GigE (copper) eNAS


Figure 29 Front-end I/O module: 10 GigE (copper) eNAS

0 1

SYM-002861

0
SYM-002862

#31 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Dual Port 10GbE BaseT interface
l Copper media via RJ45 connector

Front-end I/O module: 10 GigE (copper) eNAS 45


DELL EMC CONFIDENTIAL
Engine Components

Front end I/O module: 1 GigE eNAS


Figure 30 Front end I/O module: 1 GigE eNAS

SYM-002875

SYM-002876

#28 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Quad Port 1GbE BaseT interface
l 4 lane PCIE Gen1.0 interface
l Copper media via RJ45 connector

46 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Engine Components

Front end I/O module: Mixed Fibre Channel and Ethernet


SRDF
Figure 31 Front end I/O module: Mixed Fibre Channel and Ethernet SRDF

0 1 2 3
SYM-002855

3
2
1
0

SYM-002856

#26 - Part number information about I/O modules is available at Engine component
part numbers on page 78.
Configuration Details
l Quad Port 8G Fibre Channel interface
l Copper (4G) and optical (8G) media via SFP+ connector
Rules of Mixed Layouts
l FC installed in pairs, odd even directors
l Ethernet installed in pairs, odd even directors
l Any combination of pairs allowed

Front end I/O module: Mixed Fibre Channel and Ethernet SRDF 47
DELL EMC CONFIDENTIAL
Engine Components

48 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 4
I/O Modules

This chapter matches I/O modules to slots and the software emulations that run on
them.
Topics include:

l Vault flash - slots 0, 1 and 6, 7............................................................................50


l Fabric - slot 10.................................................................................................... 51
l SAS back end - slots 4, 5................................................................................... 52
l Front end connectivity - slots 2, 3 and 8, 9........................................................ 53

I/O Modules 49
DELL EMC CONFIDENTIAL
I/O Modules

Vault flash - slots 0, 1 and 6, 7


Figure 32 Engine rear view - vault flash

Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10

Even Director

Odd Director

Front-end
I/O modules Vault Front-end
Vault SAS Flash I/O modules Fabric
Flash Back End (SIB)

Table 3 Vault flash

Color Technology Hardware SlicMap Part Number


Label
Green - Flash 400GB v2 Windstorm 400G 303-404-001A

Green - Flash 800GB v2 Windstorm 800G 303-404-000A

Light Green label - FLASH Whirlwind 350G 313-270-101A


350 v1

Light Green label - FLASH Whirlwind 700G 313-270-102A


700 v1

Note

Intermixing Windstorm and Whirlwind I/O modules is not allowed.

50 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
I/O Modules

Fabric - slot 10
Figure 33 Engine rear view - fabric

Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10

Even Director

Odd Director

Front-end
I/O modules Vault Front-end
Vault SAS Flash I/O modules Fabric
Flash Back End (SIB)

Table 4 Fabric

Color Technology Hardware SlicMap Part Number


Label
Cyan - 56 Gb IB v2 Gorgon 303-266-101A

Fabric - slot 10 51
DELL EMC CONFIDENTIAL
I/O Modules

SAS back end - slots 4, 5


Figure 34 Engine rear view - SAS back end

Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10

Even Director

Odd Director

Front-end
I/O modules Vault Front-end
Vault SAS Flash I/O modules Fabric
Flash Back End (SIB)

Table 5 SAS back end

Color Hardware SlicMap DirMap Part Number


Technology Emulation
Label
Black label - 6 Gb Moonshadow 303-161-101B
SAS v3

52 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
I/O Modules

Front end connectivity - slots 2, 3 and 8, 9


Figure 35 Engine rear view - front end connectivity

Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot Slot
0 1 2 3 4 5 6 7 8 9 10

Even Director

Odd Director

Front-end
I/O modules Vault Front-end
Vault SAS Flash I/O modules Fabric
Flash Back End (SIB)

2
Physical ports Logical ports
1 (mapped to
emulation)
0

Table 6 Host connectivity - Fibre Channel and SRDF

Color Hardware SlicMap DirMap Emulation Part Number


Technology
Label
Gray - 8 Gb Fibre Glacier 303-092-102B

Rainfall 303-290-100B-01

Sage - 10 GbE/ Heatwave 303-142-100A


FCoE

White - 16 Gb VortexQ 303-220-300D


Fibre v1

Front end connectivity - slots 2, 3 and 8, 9 53


DELL EMC CONFIDENTIAL
I/O Modules

Table 7 Host connectivity - GigE iSCSI and SRDF

Color Hardware SlicMap DirMap Emulation Part Number


Technology
Label
Light green - 10 Rainstorm E 303-235-102B-02
GbE/FCoE V2

Tan - 1 GbE Thunderbolt 303-122-100B

Tan - 1 GbE Thunderchild 303-121-100A

Table 8 eNAS connectivity

Color Technology Hardware SlicMap Part Number


Label
Orange - 10 GbE v3 El Nino 303-195-100C-01

Orange - 10 GbE BaseT Eruption 303-164-104D-01

Gray - 8 Gb Fibre Glacier (tape 303-092-102B


backup)

54 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 5
Storage Components

Topics include:

l 60-drive DAE..................................................................................................... 56
l 60-drive DAE layout and power distribution....................................................... 58
l 120-drive DAE.................................................................................................... 59
l 120-drive DAE layout and power distribution......................................................60
l SAS cabling, single-engine..................................................................................61
l SAS cabling, dual-engine....................................................................................62

Storage Components 55
DELL EMC CONFIDENTIAL
Storage Components

60-drive DAE
Figure 36 60-drive DAE

ICM
#42
LCC B
#41 Power Supply
#40
LCC A
#41
Disk
Fan
#43

ICM A
Power Supply B Power Supply A

ICM B

0 1 0 1

B0 B1 A0 A1
Rear view

Part number information about components #40 - #43 is available at DAE part
numbers on page 80.

Part number information about 3.5 inch disks is available at 3.5 inch drive part
numbers on page 81.
Configuration Details
l 60 3.5'' SAS disk drives
l 6G SAS connectivity
l 100K: 720 drives, two bays
l 200K: 1440 Drives, four bays
l 400K: 2880 drives, eight bays
l All:

56 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Storage Components

n 2/4 TB 7.2K RPM SAS


n 300 GB, 600 GB, 1.2 TB 10K RPM SAS
n 300 GB 15K RPM SAS
n 200, 400, 800 GB, 1.2 TB Flash SAS

60-drive DAE 57
DELL EMC CONFIDENTIAL
Storage Components

60-drive DAE layout and power distribution


Figure 37 60-drive DAE layout and power distribution

PS A1 PS A0 PS B1 PS B0

E (0-11)

D (0-11)

C (0-11)

B (0-11)

A (0-11)

Fan 00 Fan 01 Fan 02

Front

Configuration Details
l Input 1340 W
l Output 1200 W
l N+1 fans with adaptive cooling
l Four power rails on Baseboard
l Four power cords (2 on each rail)
l 15W/drive slot

58 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Storage Components

120-drive DAE
Figure 38 120-drive DAE

#45
Rear
PWS B0 PWS B1 PWS A0 PWS A1

DC DC DC DC

AC AC AC AC

1 0 1 0 1 0 1 0

Rear
= PRI
Fans 5-9
= EXP
LCC B LCC A #47 F
F
#48 #48
0 19

E E
0 19
Drives
#46
D D
0 19

#47
Fan 0 Fan 1 Fan 2 Fan 3 Fan 4 C
0
C
19

B B
0 19

A A
0 19

Front SSC Fans 0-4


#49 #47
Front

Part number information about components #45 - #49 is available at DAE part
numbers on page 80.

Part number information about 2.5 inch drives is available at 2.5 inch drive part
numbers on page 81.
Configuration Details
l 120 2.5" drives
l 6G SAS connectivity
l 100K, 200K: 2880 drives, four bays
l 400K: 5760 drives, eight bays
l All:

120-drive DAE 59
DELL EMC CONFIDENTIAL
Storage Components

n 300 GB, 600 GB, 1.2 TB 10K RPM SAS


n 300 GB 15K RPM SAS
n 200, 400, 800 GB, 1.6 TB Flash SAS

120-drive DAE layout and power distribution


Figure 39 120-drive DAE layout and power distribution

Power Supply A Power Supply B

PS A1 PS A0 PS B1 PS B0

Fan 05 Fan 09

F (0 - 19) F
0
F
19

E (0 - 19) E
0
E
19

D (0 - 19) D
0
D
19

C (0 - 19) C
0
C
19

B (0 - 19) B
0
B
19

A (0 - 19) A
0
A
19

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
1 2 3 4
046-001-026_01

Fan 00 Fan 01 Fan 02 Fan 03 Fan 04

Configuration Details
l Max. Output Power: 2160W (10W/drive slot)
l Power Architecture: N+1
l Total Power Inputs: 4 (AC)
l SPS Support: Yes
l Cooling Mode: Adaptive Cooling, N+2

60 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Storage Components

SAS cabling, single-engine


Figure 40 SAS cabling, single-engine

Engine

3
PWS-

1
B

2
0

0
1

1
PWS-

0
A

0
3

3
PWS-

1
B

2
0

0
1

1
AC

0
IN

0
038-018-150 (3m)

038-018-150 (3m)

038-018-150 (3m)
038-018-150 (3m)
PWS B0 PWS B1 PWS A0 PWS A1
DAE 6
1 0 1 0 1 0 1 0

038-018-026 (3m)
PWS B0 PWS B1 PWS A0 PWS A1
DAE 5
038-018-026 (3m)

1 0 1 0 1 0 1 0

PWS B0 PWS B1 PWS A1


DAE 4PWS A0
1 0 1 0 1 0 1 0

0 0
PWS-B PWS-A
1 DAE 3 1
0 0
1 1
038-018-026 (3m)

B0 B1 A0 A1
038-018-026 (3m)

0 0
1 PWS-B DAE 2 PWS-A
1
0 0
1 B0 B1 A0 A1 1

0 0
PWS-B PWS-A
1 DAE 1 1
0 0
1 B0 B1 A0 A1 1

In the illustration:
l DAEs 1 - 3 are 60 3.5" disk drives
l DAEs 4 - 6 are 120 2.5" disk drives

Part number information about DAE cables is available at Cable part numbers on
page 82.
Configuration Details
l Connect DAE cables from DAEs at the bottom of the bay and work up.
l Route, connect and dress all power cables for one DAE before beginning the next.
l DAE 1 daisy-chains to DAE 2

SAS cabling, single-engine 61


DELL EMC CONFIDENTIAL
Storage Components

l DAE 2 daisy-chains to DAE 3


l DAE 3 connects directly to odd and even directors.
l DAE 4 daisy-chains to DAE 5
l DAE 5 daisy-chains to DAE 6
l DAE 4 connects directly to odd and even directors
l Daisy-chain connections cables - PN 038-018-026
l Direct connection cables - PN 038-100-150

SAS cabling, dual-engine


Figure 41 SAS cabling, dual-engine

Engine— Odd
3

3
PWS-
1

1
B
2

2
0

0
1

1
PWS-
0

0
A
0

0
3

3
All cables are PN 038-000-150

PWS-
1

1
B
2

2
0

0
1

1
AC
0

0
IN
0

0
Engine— Even
3

PWS-
1

B 1
2

2
0

0
1

PWS-
0

A
0

0
3

PWS-
1

B
2

2
0

0
1

AC
0

IN
0

0 0
PWS-B PWS-A
1 DAE 4 1
0 0
1 B0 B1 A0 A1 1
w_dual_dae_3_4_voy

0 0
1 PWS-B DAE 3 PWS-A
1
0 0
1 B0 B1 A0 A1 1

PWS BO PWS B1 PWS A0 PWS A1


DAE 2
1 0 1 0 1 0 1 0

PWS B0 PWS B1 PWS A0 PWS A1

DAE 1
1 0 1 0 1 0 1 0

Part number information about DAE cables is available at Cable part numbers on
page 82.

62 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Storage Components

Configuration Details
l Connect DAE cables from DAEs at the bottom of the bay and work up.
l Route, connect and dress all power cables for one DAE before beginning the next.
l DAEs 1 and 2 - four SAS cables connect each DAE to alternate directors on the
even (lower) engine)
l DAEs 3 and 4 - four SAS cables connect each DAEs to alternate directors on the
odd (upper) engine.
l All SAS cables are PN 038-000-150 (3m)

SAS cabling, dual-engine 63


DELL EMC CONFIDENTIAL
Storage Components

64 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 6
Power Components

Topics include:

l PDU, three-phase.............................................................................................. 66
l PDU, single-phase...............................................................................................71

Power Components 65
DELL EMC CONFIDENTIAL
Power Components

PDU, three-phase
Figure 42 PDU, three-phase

PDU, three-phase
3 2 1 4 5 6

Rear view
6 5 4 1 2 3
3 2 1 4 5 6

PDU 12 11 10 9 8 7 6 5 4 3 2 1 13 14 15 16 17 18 19 20 21 22 23 24 PDU
Zone B 24 23 22 21 20 19 18 17 16 15 14 13 1 2 3 4 5 6 7 8 9 10 11 12 Zone A

6 5 4 1 2 3

Rear view

Part number information for this component (#5, #6) is available at System bay
part numbers on page 78.
Configuration Details
PDUs with three-phase transmission use 2 AC main cables (one each side) that
connect to all components.
Check that PDU numbers match component (1111, 2222 etc)

66 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Power Components

PDU cabling, three-phase, single-engine, system bay 1


Figure 43 PDU cabling, three-phase, single-engine, system bay 1

PDU cabling, three-phase, single-engine, system bay 1

DAE 4, PWS-B0 DAE 1, PWS-A0


DAE 3, PWS-B0 DAE 2, PWS-A1
DAE 2, PWS-B0 empty
Lightbar, side B empty
empty DAE 4, PWS-A1
DAE 5, PWS-B0 DAE 6, PWS-A1
DAE 6, PWS-B0 DAE 3, PWS-A1
empty empty
SPS 3B SPS 1A
KVM DAE 5, PWS-A1
Ethernet switch B DAE 1, PWS-A1
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
DAE 1, PWS-B1 Ethernet switch A
DAE 5, PWS-B1 empty
SPS 1B SPS 3A
empty empty
DAE 3, PWS-B1 DAE 6, PWS-A0
DAE 6, PWS-B1 DAE 5, PWS-A0
DAE 4, PWS-B1 empty
empty Lightbar, side A
empty DAE 2, PWS-A0
DAE 2, PWS-B1 DAE 3, PWS-A0
DAE 1, PWS-B0 DAE 4, PWS-A0

Rear view

Note

Wiring is the same for three-phase Delta and three-phase Wye.

Configuration Details
l Three-phase Delta - 2 drops/bay
l Three-phase Wye - 2 drops/bay
See also:
l PDU cabling, three-phase, single-engine, system bays 2-8 on page 68

PDU cabling, three-phase, single-engine, system bay 1 67


DELL EMC CONFIDENTIAL
Power Components

PDU cabling, three-phase, single-engine, system bays 2-8


Figure 44 PDU cabling, three-phase, single-engine, system bays 2-8

PDU cabling, three-phase, single-engine, system bays 2-8

DAE 4, PWS-B0 DAE 1, PWS-A0


DAE 3, PWS-B0 DAE 2, PWS-A1
DAE 2, PWS-B0 empty
Lightbar, side B empty
empty DAE 4, PWS-A1
DAE 5, PWS-B0 DAE 6, PWS-A1
DAE 6, PWS-B0 DAE 3, PWS-A1
empty empty
SPS 3B empty
empty DAE 5, PWS-A1
Worktray DAE 1, PWS-A1
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
DAE 1, PWS-B1 empty
DAE 5, PWS-B1 empty
empty SPS 3A
empty empty
DAE 3, PWS-B1 DAE 6, PWS-A0
DAE 6, PWS-B1 DAE 5, PWS-A0
DAE 4, PWS-B1 empty
empty Lightbar, side A
empty DAE 2, PWS-A0
DAE 2, PWS-B1 DAE 3, PWS-A0
DAE 1, PWS-B0 DAE 4, PWS-A0

Rear view

Note

Wiring is the same for three-phase Delta and three-phase Wye.

Configuration Details
l Three -phase Delta - 2 drops/bay
l Three-phase Wye - 2 drops/bay
See also:
l PDU cabling, three-phase, single-engine, system bay 1 on page 67

68 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Power Components

PDU cabling, three-phase, dual-engine, system bay 1


Figure 45 PDU cabling, three-phase, dual-engine, system bay 1

PDU cabling, three-phase, dual-engine, system bay 1

DAE 4, PWS-B0 DAE 1, PWS-A0


DAE 3, PWS-B0 DAE 2, PWS-A1
DAE 2, PWS-B0 empty
Lightbar, side B empty
empty DAE 4, PWS-A1
SPS 2B empty
empty DAE 3, PWS-A1
empty empty
SPS 3B SPS 1A
KVM empty
Ethernet switch B DAE 1, PWS-A1
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
DAE 1, PWS-B1 Ethernet switch A
empty empty
SPS 1B SPS 3A
empty empty
DAE 3, PWS-B1 empty
empty SPS 2A
DAE 4, PWS-B1 empty
empty Lightbar, side A
empty DAE 2, PWS-A0
DAE 2, PWS-B1 DAE 3, PWS-A0
DAE 1, PWS-B0 DAE 4, PWS-A0

Rear view

Note

Wiring is the same for three-phase Delta and three-phase Wye.

Configuration Details
l Three-phase Delta - 2 drops/bay
l Three-phase Wye - 2 drops/bay
See also:
l PDU cabling, three-phase, dual-engine, system bays 2-4 on page 70

PDU cabling, three-phase, dual-engine, system bay 1 69


DELL EMC CONFIDENTIAL
Power Components

PDU cabling, three-phase, dual-engine, system bays 2-4


Figure 46 PDU cabling, three-phase, dual-engine, system bays 2-4

PDU cabling, three-phase, dual-engine, system bays 2-4

DAE 4, PWS-B0 DAE 1, PWS-A0


DAE 3, PWS-B0 DAE 2, PWS-A1
DAE 2, PWS-B0 empty
Lightbar, side B empty
empty DAE 4, PWS-A1
SPS 2B empty
empty DAE 3, PWS-A1
empty empty
SPS 3B empty
Worktray DAE 1, PWS-A1
empty empty
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
empty empty
DAE 1, PWS-B1 empty
empty SPS 3A
empty empty
DAE 3, PWS-B1 empty
empty SPS 2A
DAE 4, PWS-B1 empty
empty Lightbar, side A
empty DAE 2, PWS-A0
DAE 2, PWS-B1 DAE 3, PWS-A0
DAE 1, PWS-B0 DAE 4, PWS-A0

Rear view

Note

Wiring is the same for three-phase Delta and three-phase Wye.

Configuration Details
l Three-phase Delta - 2 drops/bay
l Three-phase Wye - 2 drops/bay
See also:
l PDU cabling, three-phase, dual-engine, system bay 1 on page 69

70 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Power Components

PDU, single-phase
Figure 47 PDU, single-phase

Front view
PDU, single-phase

3 2 1 4 5 6

Rear view
6 5 4 1 2 3
3 2 1 4 5 6

PDU 12 11 10 9 8 7 6 5 4 3 2 1 13 14 15 16 17 18 19 20 21 22 23 24 PDU
Zone B 24 23 22 21 20 19 18 17 16 15 14 13 1 2 3 4 5 6 7 8 9 10 11 12 Zone A

6 5 4 1 2 3

Rear view

Part number information for this component (#4) is available at System bay part
numbers on page 78.
Configuration Details
l Three 30A, single-phase drops per zone.
l Two power zones require 6 drops, each drop rated for 30A.
l PDU A and PDU B require three separate single-phase 30A drops for each PDU.

PDU, single-phase 71
DELL EMC CONFIDENTIAL
Power Components

PDU cabling, single-phase, single-engine, system bay 1


Figure 48 PDU cabling, single-phase, single-engine, system bay 1

PDU cabling, single-phase, single-engine, system bay 1

DAE 3, PWS-B0 SPS 3A


DAE 3, PWS-B1 Ethernet switch A
SPS 1B empty
Lightbar, side B empty
DAE 4, PWS-B0 DAE 6, PWS-A0
DAE 4, PWS-B1 DAE 6, PWS-A1
DAE 5, PWS-B0 DAE 5, PWS-A1
empty empty
DAE 1, PWS-B0 DAE 1, PWS-A1
DAE 2, PWS-B0 empty
DAE 2, PWS-B1 empty
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
empty DAE 2, PWS-A1
empty DAE 2, PWS-A0
DAE 1, PWS-B1 DAE 1, PWS-A0
empty empty
DAE 5, PWS-B1 DAE 5, PWS-A0
DAE 6, PWS-B1 DAE 4, PWS-A1
DAE 6, PWS-B0 DAE 4, PWS-A0
empty Lightbar, side A
KVM SPS 1A
Ethernet switch B DAE 3, PWS-A1
SPS 3B DAE 3, PWS-A0

Rear view

Configuration Details
l Single-phase - Up to 6 drops/bay
See also:
l PDU cabling, single-phase, single-engine, system bays 2-8 on page 73

72 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Power Components

PDU cabling, single-phase, single-engine, system bays 2-8


Figure 49 PDU cabling, single-phase, single-engine, system bays 2-8

PDU cabling, single-phase, single-engine, system bays 2-8

DAE 3, PWS-B0 SPS 3A


DAE 3, PWS-B1 empty
empty empty
Lightbar, side B empty
DAE 4, PWS-B0 DAE 6, PWS-A0
DAE 4, PWS-B1 DAE 6, PWS-A1
DAE 5, PWS-B0 DAE 5, PWS-A1
empty empty
DAE 1, PWS-B0 DAE 1, PWS-A1
DAE 2, PWS-B0 empty
DAE 2, PWS-B1 empty
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
empty DAE 2, PWS-A1
empty DAE 2, PWS-A0
DAE 1, PWS-B1 DAE 1, PWS-A0
empty empty
DAE 5, PWS-B1 DAE 5, PWS-A0
DAE 6, PWS-B1 DAE 4, PWS-A1
DAE 6, PWS-B0 DAE 4, PWS-A0
empty Lightbar, side A
Worktray empty
empty DAE 3, PWS-A1
SPS 3B DAE 3, PWS-A0

Rear view

Configuration Details
l Single-phase - Up to 6 drops/bay
See also:
l PDU cabling, single-phase, single-engine, system bay 1 on page 72

PDU cabling, single-phase, single-engine, system bays 2-8 73


DELL EMC CONFIDENTIAL
Power Components

PDU cabling, single-phase, dual-engine, system bay 1


Figure 50 PDU cabling, single-phase, dual-engine, system bay 1

PDU cabling, single-phase, dual-engine, system bay 1

DAE 3, PWS-B0 SPS 3A


DAE 3, PWS-B1 Ethernet switch A
SPS 1B empty
Lightbar, side B empty
DAE 4, PWS-B0 SPS 2A
DAE 4, PWS-B1 empty
empty empty
empty empty
DAE 1, PWS-B0 DAE 1, PWS-A1
DAE 2, PWS-B0 empty
DAE 2, PWS-B1 empty
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
empty DAE 2, PWS-A1
empty DAE 2, PWS-A0
DAE 1, PWS-B1 DAE 1, PWS-A0
empty empty
empty empty
empty DAE 4, PWS-A1
SPS 2B DAE 4, PWS-A0
empty Lightbar, side A
KVM SPS 1A
Ethernet switch B DAE 3, PWS-A1
SPS 3B DAE 3, PWS-A0

Rear view

Configuration Details
l Single-phase - Up to 6 drops/bay
See also:
l PDU cabling, single-phase, dual-engine, system bays 2-4 on page 75

74 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Power Components

PDU cabling, single-phase, dual-engine, system bays 2-4


Figure 51 PDU cabling, single-phase, dual-engine, system bays 2-4

PDU cabling, single-phase, dual-engine, system bays 2-4

DAE 3, PWS-B0 SPS 3A


DAE 3, PWS-B1 empty
empty empty
Lightbar, side B empty
DAE 4, PWS-B0 SPS 2A
DAE 4, PWS-B1 empty
empty empty
empty empty
DAE 1, PWS-B0 DAE 1, PWS-A1
DAE 2, PWS-B0 empty
DAE 2, PWS-B1 empty
empty empty

PDU 3 3 3 3 2 2 2 2 1 1 1 1 4 4 4 4 5 5 5 5 6 6 6 6 PDU
Zone B 6 6 6 6 5 5 5 5 4 4 4 4 1 1 1 1 2 2 2 2 3 3 3 3 Zone A

empty empty
empty DAE 2, PWS-A1
empty DAE 2, PWS-A0
DAE 1, PWS-B1 DAE 1, PWS-A0
empty empty
empty empty
empty DAE 4, PWS-A1
SPS 2B DAE 4, PWS-A0
empty Lightbar, side A
Worktray empty
empty DAE 3, PWS-A1
SPS 3B DAE 3, PWS-A0

Rear view

Configuration Details
l Single-phase - Up to 6 drops/bay
See also:
l PDU cabling, single-phase, dual-engine, system bay 1 on page 74

PDU cabling, single-phase, dual-engine, system bays 2-4 75


DELL EMC CONFIDENTIAL
Power Components

76 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL

CHAPTER 7
Part Numbers

Topics include:

l System bay part numbers ..................................................................................78


l Engine component part numbers........................................................................78
l DAE part numbers..............................................................................................80
l 3.5 inch drive part numbers................................................................................ 81
l 2.5 inch drive part numbers................................................................................ 81
l 3rd party part numbers...................................................................................... 82
l Cable part numbers............................................................................................ 82

Part Numbers 77
DELL EMC CONFIDENTIAL
Part Numbers

System bay part numbers


Part name Part number Notes

#1 SPS (without battery) 078-000-080 No SPS for DAEs, labels on both front/back
doors

Lithium ion SPS battery 078-000-198 or


078-000-111

Lithium ion SPS battery 078-000-082 2nd source for 078-000-198 or 078-000-111

#2 MIBE, 12 port fabric switch 100-886-605-01 Only one type of MIBE in system. Specify
either 12 or 18 ports
#3 MIBE, 18 port fabric switch 100-886-604-00

MIBE, 18 port power supply 071-000-588

MIBE, 18 port cooling module 045-000-224 The 4 embedded fans cannot be replaced
individually.

#4 PDU - single-phase 100-564-177-00 Only one PDU per power zone

#5 PDU - three-phase Wye 100-887-122-00 Only one PDU per power zone

#6 PDU - three-phase Delta 100-887-121-00 Only one PDU per power zone

#7 Ethernet switch 100-563-659

#8 KVM 091-000-094

Rear door LED 100-887-028-00 LED front in system bay 2

Front door LED 100-887-108-01

Front light bar AC/DC power supply 100-887-111-00

Engine component part numbers


Part name Part number Notes

#9 MMCS 100-886-218-07 MMCS is named by the director that cools it


(aligned to it)
#10 MMCS 100-887-103-03

#11 350 G vault flash I/O module 313-270-101A-00 Light Green label - FLASH 350 v1

#12 700 G vault flash I/O module 313-270-102A-00 Light Green label - FLASH 700 v1

#13 6 core director (without memory) 110-188-350C-02

#14 8 core director - unpopulated 110-188-351C-02 Field spare for 110-188-322C-02,


110-188-323C-02 and 110-188-324C-01

#15 12 core director - unpopulated 110-188-353C-02 Field spare for 110-188-331C-01,


110-188-332C-01 and 110-188-335C-01

#16 Director 800 W power supply 071-000-555-01

78 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Part Numbers

Part name Part number Notes

Director 800 W power supply 071-000-556 2nd source spares

#17 Director 1100 W power supply 071-000-578-01

Director 1100 W power supply 071-000-579 2nd source spares

#18 Director fan 100-565-011-01 Slots are labeled 0-4

Director boot drive assembly 005050898

#19 Management module (Akula II) 303-288-000A-00 Management module is named by the director
that cools it (aligned to it)

#20 SAS back-end I/O module 303-161-101B-05 Black label - 6 Gb SAS v3

#21 DIMM - 4 Gb 100-563-383 Memory module: 4 Gb REG. DIMM


TLA,DDR3-1600

#22 DIMM - 8 Gb 100-563-384 Memory module: 8 Gb REG. DIMM


TLA,DDR3-1600

#23 DIMM - 16 Gb 100-564-111 Memory module: 16 Gb REG. DIMM


TLA,DDR3-1600

#24 DIMM - 32 Gb 100-563-491 Memory module: 32 Gb REG. DIMM


TLA,DDR3-1600

#25 DIMM - 64 Gb 100-887-105-00 Memory module: 64 Gb L REG. DIMM


DDR-1333

#26 Front-end I/O module, 8 Gb Fibre Channel 303-092-102B Gray label - 8 Gb Fibre

#27 Front-end I/O module, 8 Gb Fibre Channel 303-120-100B Pink label - 8 Gb Fibre / Ficon

#28 Front-end I/O module, 1 Gb copper Ethernet 303-121-100A Tan label - 1 GbE

#29 Front-end I/O module, 1 Gb copper Ethernet 303-122-100B Tan label - 1 GbE

#30 Front-end I/O module, 10 Gb 303-142-100A Sage label - 10 GbE/FCoE

#31 Front-end I/O module, 10 Gb copper Ethernet 303-164-104D-01 Orange label - 10 GbE BaseT

#32 Front-end I/O module, 10Gb 303-235-102B-01 10Gb FCoE


Light green label - 10 GbE/FCoE V2

Front-end I/O module, 10Gb 303-235-102B-02 10Gb iSCSI, FCoE


Light green label - 10 GbE/FCoE V2

#33 Front-end I/O module, 16 Gb FC 303-290-100B-01

#33A Front-end I/O module, 16 Gb FICON 303-220-300D-00 White label - 16 Gb Fibre v1

#34 I/O module, 10 Gb Optical Ethernet 303-195-100C-01 Orange label - 10 GbE v3

#35 I/O module 56 Gb SIB 303-266-101A-04 56 Gb SIB when in SIB slot (x8)
Cyan label - 56 Gb IB v2

#36 16 Gb single mode SFP 019-078-047

#37 8 Gb single mode SFP 019-078-043

#38 8 Gb multi mode SFP 019-078-042

Engine component part numbers 79


DELL EMC CONFIDENTIAL
Part Numbers

Part name Part number Notes

1 Gb optical SFP 019-078-032

10 Gb optical SFP 019-078-041

16 Gb multi mode SFP 019-078-045

MIBE/SIB QSFP optical transceiver(port) 019-078-048 56 Gb IB I/O module - when in SIB slot using
SIB QSFP

#50 Engine AC cable tube 100-565-118-01 Megatron engine

DAE part numbers


Part name Part number Notes

#39 3.5 inch DAE (60 slots) 100-887-020-09

#40 3.5 inch DAE power supply 071-000-585-03 Drives Bay 1A, 60S-DAE-3,
Power Supply A

#41 3.5 inch DAE LCC 303-171-004C-01 Always replace BOTH the
LCC and ICM
#42 3.5 inch DAE ICM 303-172-004D-02

#43 3.5 inch DAE fan 303-173-000B Fans are labeled 0-2

#44 3.5 inch DAE chassis with 100-564-101-01 Does not include drives or
midplane LCCs

#45 2.5 inch DAE chassis with 100-563-654-04 Does not include drives or
midplane LCCs

#46 2.5 inch DAE (120 slots) with 100-563-655-05


875 W power supply

2.5 inch DAE (120 slots) with 100-887-110-01


1080 W power supply

2.5 inch DAE power supply 071-000-569-03

#47 2.5 inch DAE fan 100-563-653-01

#48 2.5 inch DAE LCC drive 303-197-000C-04


expander

#49 2.5 inch DAE system status 303-214-000C-02 One per DAE
card (SSC)

CMA - B Side (Upper) 100-887-117

CMA - A Side (Lower) 100-887-123

80 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Part Numbers

3.5 inch drive part numbers


Part name Part number Notes
200 GB EFD (MLC) 3.5 inch 005050712
drive
005050885 2nd source spare for 005050712

005051143 3rd source spare for 005050712

400 GB EFD (MLC) 3.5 inch 005050716


drive
005050877 2nd source spare for 005050716

005051147 3rd source spare for 005050716

800 GB EFD (MLC) 3.5 inch 005050881


drive
005051151 2nd source spare for 005050881

1.6 TB EFD (MLC) 3.5 inch drive 005051155

300 GB 10K 3.5 inch SAS drive 005050679

600 GB 10K 3.5 inch SAS drive 005050683

1.2 TB 10K 3.5 inch SAS drive 005050725

300 GB 15K 3.5 inch SAS drive 005050900

2 TB 7.2K 3.5 inch SAS EV drive 005050733

4 TB 7.2K 3.5 inch SAS drive 005050735

2.5 inch drive part numbers


Part name Part number Notes
200 GB EFD (MLC) 2.5 inch SAS 005050714
drive
005050875 2nd source spare for 005050714

005051145 3rd source spare for 005050714

400 GB EFD (MLC) 2.5 inch drive 005050718

005050879 2nd source spare for 005050718

005051149 3rd source spare for 005050718

800 GB EFD (MLC) 2.5 inch drive 005050883

005051153 2nd source spare for 005050883

300 GB 10K 2.5 inch SAS drive 005050681

300 GB 15K 2.5 inch SAS drive 005050899

600 GB 10K 2.5 inch SAS drive 005050685

1.2 TB 10K 2.5 inch SAS drive 005050727

1.6 TB EFD (MLC) 2.5 inch drive 005051157

3.5 inch drive part numbers 81


DELL EMC CONFIDENTIAL
Part Numbers

3rd party part numbers


Part name Part number
3rd party light bar bezel 100-887-104-02

3rd party engine bezel 100-887-102-02

3rd party Ethernet switch 100-887-080-00

3rd party AC/DC power supply front door LED 100-887-076-00

3rd party light bar cable 038-001-110

3rd party glow bezel mono cable 038-900-021

Network Ethernet port dongle (for MMCS) 038-003-718

Cable part numbers


DAE SAS cables
Cable Part number
SAS direct - 3 meter (118.11 inch) 038-000-150-00

SAS daisy - 3 meter (118.11 inch) 038-018-026-00

SAS daisy - 5 meter (196.85 inch) 038-018-028-00

Fabric cables
Cable Part number
IB cable - 2 meter (78.74 inch) 038-004-066-01

IB cable - 3 meter (118.11 inch) 038-004-067-01

IB cable - 5 meter (196.85 inch) 038-900-027-01

IB cable - 8 meter (314.96 inch) 038-900-030-01

82 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Part Numbers

Ethernet cables - dispersed bays


Cable Part number
Ethernet bundle: engine 2 Ethernet switch A - 30 meter (98.5 feet) 038-004-122

Ethernet bundle: engine 2 Ethernet switch B - 30 meter (98.5 feet) 038-004-259

Ethernet bundle: engine 3 Ethernet switch A - 30 meter (98.5 feet) 038-004-325

Ethernet bundle: engine 3 Ethernet switch B - 30 meter (98.5 feet) 038-004-327

Ethernet bundle: engine 4 Ethernet switch A - 30 meter (98.5 feet) 038-004-328

Ethernet bundle: engine 4 Ethernet switch B - 30 meter (98.5 feet) 038-004-329

Ethernet bundle: engine 5 Ethernet switch A - 30 meter (98.5 feet) 038-004-352

Ethernet bundle: engine 5 Ethernet switch B - 30 meter (98.5 feet) 038-004-353

Ethernet bundle: engine 6 Ethernet switch A - 30 meter (98.5 feet) 038-004-354

Ethernet bundle: engine 6 Ethernet switch B - 30 meter (98.5 feet) 038-004-355

Ethernet bundle: engine 7 Ethernet switch A - 30 meter (98.5 feet) 038-004-356

Ethernet bundle: engine 7 Ethernet switch B - 30 meter (98.5 feet) 038-004-357

Ethernet bundle: engine 8 Ethernet switch A - 30 meter (98.5 feet) 038-004-358

Ethernet bundle: engine 8 Ethernet switch B - 30 meter (98.5 feet) 038-004-359

Fabric cables - dispersed bays


Cable Part number
Optical bundle: engine 2 fabric A - 30 meter (98.5 feet) 038-004-360

Optical bundle: engine 2 fabric B - 30 meter (98.5 feet) 038-004-361

Optical bundle: engine 3 fabric A - 30 meter (98.5 feet) 038-004-362

Optical bundle: engine 3 fabric B - 30 meter (98.5 feet) 038-004-369

Optical bundle: engine 4 fabric A - 30 meter (98.5 feet) 038-004-395

Optical bundle: engine 4 fabric B - 30 meter (98.5 feet) 038-004-404

Optical bundle: engine 5 fabric A - 30 meter (98.5 feet) 038-004-438

Optical bundle: engine 5 fabric B - 30 meter (98.5 feet) 038-004-439

Optical bundle: engine 6 fabric A - 30 meter (98.5 feet) 038-004-440

Optical bundle: engine 6 fabric B - 30 meter (98.5 feet) 038-004-441

Optical bundle: engine 7 fabric A - 30 meter (98.5 feet) 038-004-442

Optical bundle: engine 7 fabric B - 30 meter (98.5 feet) 038-004-443

Optical bundle: engine 8 fabric A - 30 meter (98.5 feet) 038-004-444

Optical bundle: engine 8 fabric B - 30 meter (98.5 feet) 038-004-445

Cable part numbers 83


DELL EMC CONFIDENTIAL
Part Numbers

Power cables
Cable Zone Where Used Part number
AC cable 39 inch (. Black SPS to engine, SPS 038-004-338
9906 meter) to PDU, PDU to
lightbar

AC cable 39 inch (. Gray SPS to engine, SPS 038-004-339


9906 meter) to PDU, PDU to
lightbar

AC cable 48 inch Gray SPS to engine 038-004-331


(1.219 meter)

AC cable 77 inch Black SPS to PDU 038-004-340


(1.955 meter)

AC cable 77 inch Gray SPS to PDU 038-004-341


(1.955 meter)

AC cable 7 inch Mate- Black SPS to MIBE 038-004-500


n-Lok (.1778 meter)

AC cable 7 inch Mate- Gray SPS to MIBE 038-004-501


n-Lok (.1778 meter)

AC cable 18 inch Black Ethernet to PDU 038-004-396


Mate-n-Lok (.4572
meter)

AC cable 22 inch Gray Ethernet to PDU 038-004-397


Mate-n-Lok (.5588
meter

AC cable 30 inch Black Ethernet to PDU 038-004-400


Mate-n-Lok (.7620
meter)

AC cable 30 inch Gray Ethernet to PDU 038-004-401


Mate-n-Lok (.7620
meter)

AC cable 34 inch Black SPS to MIBE 038-004-398


Mate-n-Lok (.8636
meter)

AC cable 34 inch Gray SPS to MIBE 038-004-399


Mate-n-Lok (.8636
meter)

AC cable 84 inch Black SPS to MIBE 038-004-402


Mate-n-Lok (2.134
meter)

AC cable 84 inch Gray SPS to MIBE 038-004-403


Mate-n-Lok (2.134
meter)

AC Cable 83 inch 16 Black DAE to PDU 038-004-332


awg (2.108 meter)

84 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide
DELL EMC CONFIDENTIAL
Part Numbers

Cable Zone Where Used Part number


AC Cable 83 inch 16 Gray DAE to PDU 038-004-333
awg (2.108 meter)

AC Cable 93 inch 16 Black DAE to PDU, SPS to 038-004-334


awg (2.362 meter) engine

AC Cable 93 inch 16 Gray DAE to PDU 038-004-335


awg (2.362 meter)

AC Cable 118 inch 16 Black DAE to PDU 038-004-336


awg (2.997 meter)

AC Cable 118 inch 16 Gray DAE to PDU, SPS to 038-004-337


awg (2.997 meter) engine

Power cord 58 inch Black SP L6-30P 4PPP 038-004-125


24 amp (1.473 meter)

Power cord 58 inch Gray SP L6-30P 4PPP 038-004-126


24 amp (1.473 meter)

Ethernet cables
Cable Zone Part number
Ethernet 24 inch (.6096 meter) Violet 038-004-406

Ethernet 71 inch (1.803 meter) Lime green 038-004-409

Ethernet 71 inch (1.803 meter) Violet 038-004-410

Ethernet 3 meter (118.11 inch) Lime green 038-004-411

Ethernet 3 meter (118.11 inch) Violet 038-004-412

Ethernet 5 meter (196.85 inch) Lime green 038-004-413

Ethernet 5 meter (196.85 inch) Violet 038-004-414

Ethernet 8 meter (314.96 inch) Lime green 038-004-415

Ethernet 8 meter (314.96 inch) Violet 038-004-416

CAT 6 straight Ethernet cable, 84 Red 038-004-136


inch (2.134 meters) (Customer support)

USB cables
Cable Description Part number
Rear door light bar USB, 98 inch 038-004-133
(2.489 meter)

USB cable 65 inch (1.651 meter) 038-003-941

USB male/female extension 038-004-231

RJ12 cables
Cable Part number
Micro D89 to RJ12 SPS sense 038-004-283

Cable part numbers 85


DELL EMC CONFIDENTIAL
Part Numbers

Cable Part number


RJ12 to RJ coupling 40 inch (1.016 meter) 038-004-888

RJ12 to RJ coupling 80 inch (2.032 meter) 038-004-321

Lightbar cables
Cable Part number
Front Door light bar cable 038-000-944

86 VMAX 100K, 200K, 400K 5.0 Customer Service Quick Reference Guide