CSQRG_40

The EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide provides detailed information on system and storage bay components, including layouts, configurations, and cabling for both standard and high-density drive enclosures. It includes diagrams and part numbers for various components, ensuring users have the necessary resources for maintenance and support. The guide is intended for customer service representatives and technical support personnel to assist with the VMAX 40K Series systems.

Uploaded by

tachyon.20230417
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views

CSQRG_40

The EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide provides detailed information on system and storage bay components, including layouts, configurations, and cabling for both standard and high-density drive enclosures. It includes diagrams and part numbers for various components, ensuring users have the necessary resources for maintenance and support. The guide is intended for customer service representatives and technical support personnel to assist with the VMAX 40K Series systems.

Uploaded by

tachyon.20230417
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 100

EMC CONFIDENTIAL

EMC® Symmetrix®

VMAX® 40K Series

Customer Service Quick Reference Guide


August 29, 2013
REV 06

EMC Corporation
Hopkinton, MA 01748-9103
1-508-435-1000 (in North America) 1-866-464-7381
www.EMC.com
EMC CONFIDENTIAL

Copyright ©2013 EMC Corporation. All rights reserved.

Published August 29, 2013

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.

The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect
to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular
purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.

EMC2, EMC, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries.
All other trademarks used herein are the property of their respective owners.

For the most up-to-date regulatory document for your product line, go to the technical documentation and advisories section on the
EMC online support website.

2 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Table of Contents

System and Storage Bay Components .................................................................................................................................................................. 7


System Bay Components ...................................................................................................................................................................................9
Storage Bay Components, Standard (15-Drive) DAEs .....................................................................................................................................10
Storage Bay Components, High Density (25-Drive) DAEs ...............................................................................................................................11
Three-Phase Power Components .....................................................................................................................................................................12
Single-Phase Power Components ....................................................................................................................................................................13
Front Door Light Bar .........................................................................................................................................................................................14
Engine — Front View ........................................................................................................................................................................................15
Engine — Rear View .........................................................................................................................................................................................16
MIBE — Front and Rear View ...........................................................................................................................................................................17
System Bay 1 Server Panel — Rear View ........................................................................................................................................................18
Remote Server Ports, System Bay 2 — Rear View ..........................................................................................................................................19
UPS — Front and Rear Views ..........................................................................................................................................................................20
Standard (15-Drive) DAE, Components and Chassis .......................................................................................................................................21
High Density (25-Drive) DAE, Components and Chassis .................................................................................................................................22
System Layout ..................................................................................................................................................................................................... 23
Standard Layout — Maximum Standard Configuration, 2400 Drives ...............................................................................................................25
Standard Layout — Maximum High Density Configuration, 3200 Drives .........................................................................................................26
Standard Layout — Maximum Mixed Configuration, 3040 Drives ....................................................................................................................27
2 / 6 (Dispersed at Third Engine) — Maximum Standard Configuration ...........................................................................................................28
2 / 6 (Dispersed at Third Engine) — Maximum High Density or Mixed Configuration ......................................................................................29
4 / 4 (Dispersed at Fifth Engine) — Maximum Standard Configuration ............................................................................................................30
4 / 4 (Dispersed at Fifth Engine) — Maximum High Density or Mixed Configuration .......................................................................................31
6 / 2 (Dispersed at Seventh Engine) — Maximum Standard Configuration ......................................................................................................32
6 / 2 (Dispersed at Seventh Engine) — Maximum High Density or Mixed Configuration .................................................................................33

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 3
EMC CONFIDENTIAL

Engine Components............................................................................................................................................................................................. 35
Back End Fibre Channel I/O Module, Slots and Ports — Rear View ................................................................................................................37
Fibre Channel Back End I/O Modules, Components ........................................................................................................................................38
8 and 16 Gb/s Fibre Channel Front-End I/O Modules, Slots and Ports — Rear View ......................................................................................39
8 Gb/s Fibre Channel Front-End I/O Module, Components ..............................................................................................................................40
16 Gb/s Fibre Channel Front-End I/O Module, Components ............................................................................................................................41
8 Gb/s FICON Front-End I/O Module, Slots and Ports — Rear View ...............................................................................................................42
8 Gb/s FICON Front-End I/O Module, Components .........................................................................................................................................43
GbE Front-End I/O Modules, Slots and Ports — Rear View .............................................................................................................................44
1 GbE with iSCSI or SRDF with IPsec Front-End I/O Module, Components ....................................................................................................45
10 GbE with iSCSI, FCoE or SRDF Front-End I/O Module, Components ........................................................................................................46
System Interface Board (SIB), Slots and Ports — Rear View ...........................................................................................................................47
Management Module Components ...................................................................................................................................................................48
I/O Module Carrier ............................................................................................................................................................................................49
Director .............................................................................................................................................................................................................50
LED Indicators ..................................................................................................................................................................................................51
Front-End Configurations ..................................................................................................................................................................................... 55
8 Gb/s Fibre Channel Front-End Configurations ...............................................................................................................................................57
16 Gb/s Fibre Channel Front-End Configuration ..............................................................................................................................................58
8 Gb/s FICON Front-End Configuration ............................................................................................................................................................59
GbE with iSCSI, FCoE or SRDF Front-End Configurations ..............................................................................................................................60
Mixed 8 Gb/s Fibre Channel and FICON Front-End Configurations .................................................................................................................61
Mixed 16 Gb/s Fibre Channel and FICON Front-End Configurations ...............................................................................................................62
Mixed 8 Gb/s Fibre Channel and GbE with iSCSI, FCoE or SRDF Front-End Configurations .........................................................................63
Mixed 16 Gb/s Fibre Channel & GbE with iSCSI, FCoE or SRDF Front-End Configurations ...........................................................................64
Mixed FICON and GbE with iSCSI, FCoE or SRDF Front-End Configurations ................................................................................................65
8 Gb/s Fibre Channel with Federated Tiered Storage (FTS) Front-End Options ..............................................................................................66
Cabling ................................................................................................................................................................................................................. 67
Engine 4 Back-End Cabling — Directors 7 and 8 — Rear View ......................................................................................................................69

4 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Engine 5 Back-End Cabling — Directors 9 and 10 — Rear View .....................................................................................................................70


Engine 3 Back-End Cabling — Directors 5 and 6 — Rear View .......................................................................................................................71
Engine 6 Back-End Cabling — Directors 11 and 12 — Rear View ...................................................................................................................72
Engine 2 Back-End Cabling — Directors 3 and 4 — Rear View .......................................................................................................................73
Engine 7 Back-End Cabling — Directors 13 and 14 — Rear View ...................................................................................................................74
Engine 1 Back-End Cabling — Directors 1 and 2 — Rear View .......................................................................................................................75
Engine 8 Back-End Cabling — Directors 15 and 16 — Rear View ..................................................................................................................76
Fabric (MIBE-SIB) Cabling — Rear View .........................................................................................................................................................77
Management Module Ethernet Cabling, 1- & 2-Engine — Rear View ..............................................................................................................78
Management Module Ethernet Cabling, 3- & 4-Engine — Rear View ..............................................................................................................79
Management Module Ethernet Cabling, 5- & 6-Engine — Rear View ..............................................................................................................80
Management Module Ethernet Cabling, 7- & 8-Engine — Rear View ..............................................................................................................81
Management Module Ethernet Cabling, Dispersed at Third Engine — Rear View ...........................................................................................82
Management Module Ethernet Cabling, Dispersed at Third Engine — Rear View ...........................................................................................83
Management Module Ethernet Cabling, Dispersed at Fifth Engine — Rear View ............................................................................................84
Management Module Ethernet Cabling, Dispersed at Fifth Engine — Rear View ............................................................................................85
Management Module Ethernet Cabling, Dispersed at Seventh Engine — Rear View ......................................................................................86
System Bay 1 RS-232 Cabling, SPS, UPS & MIBE — Rear View ...................................................................................................................87
Part Numbers ....................................................................................................................................................................................................... 89
Main Components .............................................................................................................................................................................................91
Ethernet Cables and Cable Bundles .................................................................................................................................................................95
Back-End Cables ..............................................................................................................................................................................................96
SIB to MIBE Copper Cables (Standard Layout) ................................................................................................................................................97
SIB to MIBE Optical Cable Bundles and QSFP (Dispersed Layouts) ...............................................................................................................99
RS-232 Sense Cables ....................................................................................................................................................................................100

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 5
EMC CONFIDENTIAL

6 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
System and Storage Bay Components
EMC CONFIDENTIAL

System Bay Components


UPS*
#13
Engine 8

!
!
A B C D

Engine 7

!
!
ON
ON I
I
O
O OFF
OFF

A B C D
PDU
MIBE 2A* ! ! ! !
MIBE 2B* MIBE 2A*
ON
ON I
I
O
O OFF
OFF

Engine 6

!
!
A B C D
ON
ON I
I
O
O OFF
OFF

Engine 5

!
!
A B C D

LAN1
LAN2 Server
KVM
#15
Engine 4

!
!
A B C D

Engine 3

!
!

A B C D
PDP
MIBE 1A* ! ! ! !

MIBE 1B* MIBE 1A*

Engine 2
!
!

A B C D

Engine 1
!
!

SPS
A B C D SPS
*System bay 1 only #11

System bay (front) System bay (rear)

Part number information about components #11, #13, and #15 is available on Table 8 on page 91. Part numbers for other components are
available on the page that shows the component.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 9
EMC CONFIDENTIAL

Storage Bay Components, Standard (15-Drive) DAEs

A
B

A
B

A
B

A
B
SPS ! ! ! ! ! ! ! !

#11

#
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
! ! ! !

! ! ! !

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
Disk drives
ON
ON I
I
O
O OFF
OFF
! ! ! ! ! ! ! !

(15 per DAE)

A
B

A
B

A
B

A
B
ON
ON I
I ! ! ! ! ! ! ! !
O
O OFF
OFF

PDU

#
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
DAE power ON
I
O
!
!

!
!

!
!

!
!

ON
I
O
OFF

PRI

PRI

PRI

PRI
OFF

PRI

PRI

PRI

PRI
supply/cooling

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
module ! ! ! ! ! ! ! !

A
B

A
B

A
B

A
B
LCC ! ! ! ! ! ! ! !

#
DAE covers

EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
! ! ! !

! ! ! !

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
PDP ! ! ! ! ! ! ! !

A
B

A
B

A
B

A
B
! ! ! ! ! ! ! !

#
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
! ! ! !

! ! ! !

PRI

PRI

PRI

PRI
PRI

PRI

PRI

PRI
EXP

EXP

EXP

EXP
EXP

EXP

EXP

EXP
#

#
! ! ! ! ! ! ! !

Power zone B Power zone A


left side right side
Storage bay (front) Storage bay (rear)
SYM-001699

Part number information about component #11 is available on Table 8 on page 91. Part numbers for other components are available on the
page that shows the component.

10 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Storage Bay Components, High Density (25-Drive) DAEs

0 24
PRI EXP

B PRI EXP

DAE 16 EXP

EXP
PRI

PRI
B

0 24
PRI EXP

B PRI EXP

DAE 15 EXP

EXP
PRI

PRI
B

PRI EXP
0 24

DAE 14
B PRI EXP

B
EXP PRI

EXP PRI

0 24

DAE 13
ON
I
O
OFF
B
PRI

PRI
EXP

EXP
ON
I
O
OFF
PDU
B
EXP PRI

SPS 4A
EXP PRI

SPS SPS 4B
cover 0 24
ON
I
PRI EXP
ON
I
#11
O B PRI EXP
O
OFF OFF

DAE 12 EXP

EXP
PRI

PRI
B

0 24
PRI EXP

B PRI EXP

DAE 11 EXP

EXP
PRI

PRI
B

0 24 ON ON
PRI EXP
I I

DAE 10
O B PRI EXP O
OFF OFF

B
EXP PRI

EXP PRI

0 24
PRI EXP

B PRI EXP

DAE 9 EXP

EXP
PRI

PRI
B

SPS 3B SPS 3A
DAE B
PRI

PRI
EXP

EXP

DAE 8
cover
B
EXP PRI

EXP PRI

PRI EXP

B PRI EXP

DAE 7 EXP

EXP
PRI

PRI
B

PRI EXP

DAE 6
B PRI EXP

B
EXP PRI

EXP PRI

PRI EXP

B PRI EXP

DAE 5 EXP

EXP
PRI

PRI
B

SPS 2B SPS 2A
PRI EXP

B PRI EXP

DAE 4 EXP

EXP
PRI

PRI
B

PRI EXP

B PRI EXP

DAE 3 EXP

EXP
PRI

PRI
B

PRI EXP

B PRI EXP

DAE 2 EXP

EXP
PRI

PRI
B

PRI EXP

B PRI EXP

DAE 1 EXP

EXP
PRI

PRI
B

SPS 1B SPS 1A

SYM-002636_qs
Storage bay (front) Storage bay (rear)

Part number information about component #11 is available on Table 8 on page 91. Part numbers for other components are available on the
page that shows the component.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 11
EMC CONFIDENTIAL

Three-Phase Power Components


System bay High Density Storage Bay Standard Storage Bay

PDU ON
I
O
OFF

ON
I

#2
O
OFF

ON
I
O
OFF

ON
I
O
OFF
ON
I
O
OFF

ON
I
O
OFF

ON
I
ON
O
OFF I
O
OFF

ON
I
O
OFF

PDP O
OFF

ON
I

#3, #4 ON
ON
I
O
OFF

I
ON
O I
OFF O
OFF O
OFF
ON
I

O
OFF

ON
I

ON
I
O
ON OFF
I
ON
O I
OFF
OI
OFF
O

4 PDUs 2 PDUs (upper) 2 PDUs (upper)


2 PDPs (lower) 2 PDPs (lower) 2 PDPs (lower)
SYM-001677_v2

Part number information about components #2, #3,and #4 is available on Table 8 on page 91.

12 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Single-Phase Power Components


System bay High Density Storage Bay Standard Storage Bay

ON

PDU
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

#2 ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF

ON
I
O
OFF
ON
I
O
OFF
ON
I
O
OFF
ON
I
O
OFF

ON
I
O
OFF
ON
I
O
OFF

OFF

ON
I
O
OFF ON
I
O
OFF

ON
I
O
OFF

PDP O
OFF

ON
I
O
OFF

ON
I

#5 ON
I
O
OFF O
OFF
O
OFF

ON
I
ON
I
O
OFF O
OFF

ON
I

ON
I

ON
I
O
OFF O
OFF

ON
I

O
OFF

ON
I

O
OFF

ON
I

ON
ON I
I O
OFF
O
OFF O
OFF ON
I
ON
OI
I OFF
O

4 PDUs 4 PDUs 4 PDUs


4 PDPs 4 PDPs 4 PDPs
SYM-002635_qs

Part number information about components #2 and #5 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 13
EMC CONFIDENTIAL

Front Door Light Bar

System or
storage bays

Light bar
#27

SYM-002079_qs

Part number information about component #27 is available on Table 8 on page 91.

14 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Engine — Front View

Engine power Engine cooling fans Engine power


supply A supply B
#9 #1 #9

A A B B C C D D
SYM-001696

Part number information about components #1 and #9 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 15
EMC CONFIDENTIAL

Engine — Rear View

Back End Back End System Interface System Interface


I/O Modules I/O Modules Boards Boards
(slot 0) (slot 1) SIB 1 (slot 2) SIB 2 (slot 3)
AC power connector

AC power connector Even director

Odd director
Front-end Front-end
ports of ports of
even director odd director
Management Front End Front End Management
Module B I/O Modules I/O Modules Module A
(slot 4) (slot 5) SYM-002637_qs

Part numbers for components in this figure are available on the page that shows the component.

16 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

MIBE — Front and Rear View

MIBE power supply/


cooling module
#10

MIBE B MIBE A
0 2 4 6 8 10 12 14 0 2 4 6 8 10 12 14
1 3 5 7 9 11 13 15 1 3 5 7 9 11 13 15

MIBE B assembly
#18

MIBE A assembly
#18 SYM-002638_qs

Part number information about components #10 and #18 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 17
EMC CONFIDENTIAL

System Bay 1 Server Panel — Rear View

KVM keyboard Ethernet to Spare


Server panel Management serial port
#37 Module B
Modem Spare
serial port Ethernet

SYM-002668_v2_qs

Power from UPS Video to KVM Ethernet to


customer network
KVM mouse Ethernet to
Management
Module A

Part number information about component #37 is available on Table 8 on page 91. This panel is used with the main server in system bay 1
(#14).

18 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Remote Server Ports, System Bay 2 — Rear View

Ethernet to Management Module A


Modem serial port of the lowest engine in system bay

PS2 mouse to KVM CS spare port

Power from UPS Video to KVM USB Customer network

PS2 keyboard to KVM Ethernet to Management Module B Server


of the highest engine in system bay #14
SYM-002084

Part number information about component #14 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 19
EMC CONFIDENTIAL

UPS — Front and Rear Views

UPS Front view


#13 Output
On Line LED Overload LED

On Battery LED Replace


Battery LED

Rear view

AC Present, AC Present,
UPS_Front_Rear_VMAX
Main Input LED AUX Input LED

Part number information about component #13 is available on Table 8 on page 91. LED information is available in Table 7 on page 54.

20 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Standard (15-Drive) DAE, Components and Chassis

DAE chassis
A B #6

A
B
! !

LCC A LCC B
#7

#
DAE power supply/ EXP port

EXP

EXP
PRI port

PRI
cooling module

PRI
A and B !
!

#8
PRI port

PRI

PRI
EXP port

EXP

EXP

#
! !

Rear Front
SYM-002080

Part number information about components #6, #7, and #8 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 21
EMC CONFIDENTIAL

High Density (25-Drive) DAE, Components and Chassis

DAE power supply/


DAE chassis
LCC B cooling module A #26
PRI portEXP port

PRI EXP

B PRI EXP

A
EXP PRI

EXP PRI

EXP portPRI port


DAE power supply/
cooling module B LCC A
#33
#32
Rear Front
SYM-002639_qs

Part number information about components #26, #32 and #33 is available on Table 8 on page 91.

22 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
System Layout
EMC CONFIDENTIAL

Standard Layout — Maximum Standard Configuration, 2400 Drives


NOTE: For an all standard DAE configuration, the maximum system configuration supports 10 storage bays.

Front view

Storage bays System bay Storage bays

7 7755 66888
Engine 8
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

2 2244 33111
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2

Daisy full Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full Daisy full
3C 2C 1C 2A 1A 1B 2B 1D 2D 3D

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 25
EMC CONFIDENTIAL

Standard Layout — Maximum High Density Configuration, 3200 Drives


NOTE: For a high density DAE configuration, the maximum system configuration supports 8 storage bays.

Front view

Storage bays System bay Storage bays

7 755 66 8 8
Engine 8
8 DA PAIR
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

2244 3311
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2

Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full
2C 1C 2A 1A 1B 2B 1D 2D

26 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Standard Layout — Maximum Mixed Configuration, 3040 Drives


NOTE: For a mix of standard and high density storage bays, the maximum system configuration supports 8 storage bays. Each engine only
supports 2 storage bays: either 2 high density, 1 high density and 1 standard, or 2 standard.
The following diagram is one example of a maximum mixed configuration.
Front view

Storage bays System bay Storage bays

7755 6688
Engine 8 8
DA15/16
8 Dir PAIR
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

2244 3311
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2
Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full
2C 1C 2A 1A 1B 2B 1D 2D

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 27
EMC CONFIDENTIAL

2 / 6 (Dispersed at Third Engine) — Maximum Standard Configuration

Front view

Storage bays System bay 1 Storage bays System bay 2 Storage bays

55 777 66 888
8 8 Engine
DA PAIR 8
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

4 4 222 33 111
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2
Daisy full Direct full Daisy full Daisy full Direct full Direct full Daisy full Direct full Daisy full Daisy full
2A 1A 3C 2C 1C 1B 2B 1D 2D 3D

28 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

2 / 6 (Dispersed at Third Engine) — Maximum High Density or Mixed Configuration

Front view

Storage bays System bay 1 Storage bays System bay 2 Storage bays

55 77 668 8
Engine 8
DA PAIR
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

44 22 3311
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2

Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full
2A 1A 2C 1C 1B 2B 1D 2D

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 29
EMC CONFIDENTIAL

4 / 4 (Dispersed at Fifth Engine) — Maximum Standard Configuration

Front view

Storage bays System bay 1 Storage bays Storage bays System bay 2 Storage bays

55 66 777 888
8 8 Engine
DA PAIR8
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

44 33 2 2 2 111
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2
Daisy full Direct full Direct full Daisy full Daisy full Daisy full Direct full Direct full Daisy full Daisy full
2A 1A 1B 2B 3C 2C 1C 1D 2D 3D

30 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

4 / 4 (Dispersed at Fifth Engine) — Maximum High Density or Mixed Configuration

Front view

Storage bays System bay 1 Storage bays Storage bays System bay 2 Storage bays

55 66 77 8 8
Engine 8
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

44 33 22 11
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2

Daisy full Direct full Direct full Daisy full Daisy full Direct full Direct full Daisy full
2A 1A 1B 2B 2C 1C 1D 2D

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 31
EMC CONFIDENTIAL

6 / 2 (Dispersed at Seventh Engine) — Maximum Standard Configuration

Front view

Storage bays System bay 1 Storage bays System bay 2 Storage bays

77755 66 888
Engine 8
8 8 Dir
DA15/16
PAIR
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

22244 33 111
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2
Daisy full Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full Daisy full
3C 2C 1C 2A 1A 1B 2B 1D 2D 3D

32 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

6 / 2 (Dispersed at Seventh Engine) — Maximum High Density or Mixed Configuration

Front view

Storage bays System bay 1 Storage bays System bay 2 Storage bays

7755 66 8 8
Engine 8
DA PAIR
Dir 15/16
Engine 7
Dir 13/14
Engine 6
Dir 11/12
Engine 5
Dir 9/10

2244 33 11
Engine 4
Dir 7/8
Engine 3
Dir 5/6
Engine 2
Dir 3/4
Engine 1
Dir 1/2

Daisy full Direct full Daisy full Direct full Direct full Daisy full Direct full Daisy full
2C 1C 2A 1A 1B 2B 1D 2D

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 33
EMC CONFIDENTIAL

34 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
Engine Components
EMC CONFIDENTIAL

Back End Fibre Channel I/O Module, Slots and Ports — Rear View

Slot 0 Slot 1

Even director

Odd director

Slot 0 Slot 1

A0, A1 C0, C1
B0, B1 D0, D1
SYM-002644_qs

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 37
EMC CONFIDENTIAL

Fibre Channel Back End I/O Modules, Components

Back End I/O Module


(without encryption)
#24

Back End I/O Module


(with encryption)
#25

e
br
Fi
b
4G
Label

0 1 2 3

SYM-002491_v2

Part number information about components #24 and#25 is available in Table 8 on page 91.

38 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

8 and 16 Gb/s Fibre Channel Front-End I/O Modules, Slots and Ports — Rear View

Slot 4 Slot 5

Even director Odd director

0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

E0, E1, F0, F1 G0,G1, H0, H1 E0, E1, F0, F1 G0,G1, H0, H1

Enginuity emmulation for Fibre Channel ports


SYM-002645_qs

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 39
EMC CONFIDENTIAL

8 Gb/s Fibre Channel Front-End I/O Module, Components

SFP+ SM module (8 Gb Fibre)


#35

Front End Fibre Channel


I/O Module
#30 0 1 2 3

8 Gb Fibre

SFP+ MM module (8 Gb Fibre) 0

#34 4G
3bre
b Fi 3

Fibre Channel 4-port I/O module options

MM MM MM MM SM SM SM SM MM MM SM MM SM MM SM MM

4 MM ports 4 SM ports 3 MM, 1 SM ports 2 MM, 2 SM ports SYM-001692_v2

Part number information about for #30, #34, #35, is available in Table 8 on page 91.

40 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

16 Gb/s Fibre Channel Front-End I/O Module, Components

0 1

Front End Fibre Channel


I/O Module
#38
16 Gb Fibre
0

SFP+ MM module (8/16 Gb Fibre) 2

bre
3

Fi
3

b
G
16
#39

Fibre Channel 2-port I/O module options


(8/16 Gb)
MM MM MM MM
SYM-001692_40K

2 MM ports 2 MM ports

Part number information about components #38 and #39 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 41
EMC CONFIDENTIAL

8 Gb/s FICON Front-End I/O Module, Slots and Ports — Rear View

Slot 4 Slot 5

Even director Odd director

01 01 01 01

E0 G0 E0 G0
E1 G1 E1 G1

Enginuity emulations for FICON ports


SYM-002646_qs

42 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

8 Gb/s FICON Front-End I/O Module, Components

SFP+ SM module (8 Gb Fibre)


#35

FICON Front End


I/O Module
#31
8 Gb Fibre/FICON 0 1

SFP+ MM module (8 Gb Fibre)


#34 0

N
O
IC
/F
re
ib
F
b
G
8
FICON 2-port I/O module options

MM MM SM SM

2 MM ports 2 SM ports SYM-001694

Part number information about components #31, #34, and #35 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 43
EMC CONFIDENTIAL

GbE Front-End I/O Modules, Slots and Ports — Rear View

Slot 4 Slot 5

Even director 1 1 1 1
Odd director
0 0 0 0

0 1 0 1 0 1 0 1

0 1 0 1 0 1 0 1

E0, F0 G0, H0 E0, F0 G0, H0

Enginuity emulations for iSCSI/FCoE and GbE SRDF ports

SYM-002647_qs

44 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

1 GbE with iSCSI or SRDF with IPsec Front-End I/O Module, Components

SFP MM module (1 GbE iSCSI)


#32

1 GbE iSCSI,GbE SRDF with IPsec

Front End iSCSI,IPSEC or


GbE SRDF I/O Module
#28

C
1

E
S
IP
bE
1G
0 1

iSCSI, GbE SRDF with IPsec 2-port I/O module option

MM MM

2 MM ports SYM-001693_ipsec

Part number information about components #28, and #32 is available on Table 8 on page 91. The GbE SRDF with IPsec option is only
available with the 1GbE I/O module.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 45
EMC CONFIDENTIAL

10 GbE with iSCSI, FCoE or SRDF Front-End I/O Module, Components


SFP MM module (10 GbE iSCSI/FCoE)
#36

10 GbE iSCSI,FCoE, GbE SRDF

Front End iSCSI, FCoE or GbE SRDF


I/O Module
#29

0
C
1
IPSE
bE
1G

0 1

iSCSI, FCoE or GbE SRDF 2-port I/O module option

MM MM

2 MM ports SYM-001693_fcoe

Part number information about components #29 and #36 is available on Table 8 on page 91. The FCoE option is only available with the 10
GbE I/O module.

46 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

System Interface Board (SIB), Slots and Ports — Rear View

SIB
#20
SIB1 Port B connects to MIBE 1B
SlB 1 SlB 2
SIB1 Port A connects to MIBE 1A
SIB2 Port B connects to MIBE 2B
B A B A
SIB2 Port A connects to MIBE 2A

Slot 3 Slot 4

Even director
Slot 3 Slot 4
Odd director

SYM-002648_qs

Part number information about component #20 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 47
EMC CONFIDENTIAL

Management Module Components

Management Management
Module B Module A
#19 #19

Management port
Service port

SYM-002649_qs

Part number information about component #19 is available on Table 8 on page 91.

48 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

I/O Module Carrier

I/O Module carrier (without compression)


I/O Module carrier (with compression)
#21
#22

Compression Label

I/O module I/O module


slot 4 slot 5
SYM-001681_v2

Part number information about component #21 and #22 is available on Table 8 on page 91.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 49
EMC CONFIDENTIAL

Director

Cache Memory Modules


#17

eFlash module

Director
#23

SYM-002650_qs

Part number information about components #17 and #23 is available on Table 8 on page 91.

50 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

LED Indicators

Table 1 Engine Enclosure LEDs

LED name Color Status

Blue:
Chassis power Blue
Power is on

Amber:
Enclosure fault Amber
Fault on director

Table 2 Engine power supply LEDs

LED name Color Status


Green:
Power Green
Power is on
Amber:
Fault Amber
Fault detected

Table 3 Blower LEDs

LED name Color Status


Amber:
Fault Amber
Fault or low fan RPM

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 51
EMC CONFIDENTIAL

Table 4 Director LEDS

LED name Color Status


Green:
Power Green
Onboard DC/DC on and within spec
White on:
Director too hot to remove
Unsafe to remove White
White off:
Safe to remove director
Off:
Board not powered
Amber:
1/4 Hz, BIOS booting
SP Fault Amber/blue
1 Hz, POST booting
4 Hz, OS booting
Blue:
OS booted

Table 5 I/O Module Carrier LEDs

LED name Color Status


Green:
Power Green
Power is on
Amber:
Fault Amber
Fault detected

52 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Table 6 Management Module LEDs

LED name Color Status


Green:
Power Green
Power is on
Amber:
Fault Amber
Fault detected
Off:
No port activity (not a fault)
Flicker:
Ethernet Port (RJ-45) Activity Amber Port activity
Flash @ 1 Hz (synchronous flash with
Link status LED):
Port marking
Off:
Inactive link (not a fault)
Flicker:
Ethernet Port (RJ-45) Link Status Green Active link connection
Flash @ 1 Hz: (synchronous flash with
Activity LED)
Port marking

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 53
EMC CONFIDENTIAL

Table 7 UPS LEDs


LED name Color Status
Green:
UPS on and operating from AC power
On Line (front) Green
Off:
UPS off
Off:
Output load within UPS rating
Output Overload (front) Red
Red:
Output exceeds UPS rating
Amber:
UPS operating on battery
On Battery (front) Amber
Off:
UPS not operating on battery
Red:
Battery is low in capacity and requires replacement (fault)
Replace Battery (front) Red
Off:
Battery is within specification
Green:
Main input AC is present
AC Present, Main Input (rear) Green
Off:
Main input AC is not present or insufficient.
Green:
Auxiliary input AC is present
AC Present, AUX Input (rear) Green
Off:
Auxiliary input AC is not present or insufficient.

54 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
Front-End Configurations
EMC CONFIDENTIAL

8 Gb/s Fibre Channel Front-End Configurations


Four 8 Gb/s Fibre Channel Front-End I/O Modules. Information about 8 Gb/s Fibre Channel hardware components is on
page 40.

FA-7H FA FA FA-8H
16 FC engine FA-7G FA FA FA-8G
FA-7F FA FA FA-8F
Even director Odd director FA-7E FA FA FA-8E
DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 G1 H0 H1 E0 E1 F0 F1 G0 G1 H0 H1
DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5
DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RF-7H RF RF RF-8H
FA-7G FA FA FA-8G
12 FC / 2 FC SRDF engine FA-7F FA FA FA-8F
Even director Odd director FA-7E FA FA FA-8E
DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 G1 H0 E0 E1 F0 F1 G0 G1 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RF-7H RF RF RF-8H
FA-7G FA FA FA-8G
RF-7F RF RF RF-8F
8 FC / 4 FC SRDF engine FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
DA-7C DA DA DA-8C
E0 E1 F0 G0 G1 H0 E0 E1 F0 G0 G1 H0 DA-7B DA DA DA-8B
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7A DA DA DA-8A
Odd Even

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 57
EMC CONFIDENTIAL

16 Gb/s Fibre Channel Front-End Configuration


Four 16 Gb/s Fibre Channel Front-End I/O Modules. Information about 16 Gb/s Fibre Channel hardware components is on
page 41.

FS-7H FS FS FS-8H
FS-7G FS FS FS-8G
8 FC engine FS-7F FS FS FS-8F
Even director Odd director FS-7E FS FS FS-8E
DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

16Gb_FC

58 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

8 Gb/s FICON Front-End Configuration


Four 8 Gb/s FICON Front-End I/O Modules. Information about 8 Gb/s FICON hardware components is on page 43.

EE EE
EF-7G EF EF EF-8G
8 FICON engine EE EE
EF-7E EF EF EF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 G0 G1 E0 E1 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001710

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 59
EMC CONFIDENTIAL

GbE with iSCSI, FCoE or SRDF Front-End Configurations


Two GbE Front-End I/O Modules. FCoE and iSCSI is provided on 10 GbE I/O Modules. FCoE is not available on 1 GbE I/O
modules. Information about GbE components is on page 45 and page 46.
SE/FE-7H SE/FE SE/FE SE/FE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
8 iSCSI or FCoE engine SE/FE-7F SE/FE SE/FE SE/FE-8F
SE/FE-7E SE/FE SE/FE SE/FE-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
6 iSCSI or FCoE/ 2 GbE SRDF engine SE/FE-7F SE/FE SE/FE SE/FE-8F
SE/FE-7E SE/FE SE/FE SE/FE-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
4 iSCSI or FCoE / 4 GbE SRDF engine RE-7F RE RE RE-8F
SE/FE-7E SE/FE SE/FE SE/FE-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-002077

60 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Mixed 8 Gb/s Fibre Channel and FICON Front-End Configurations


Two 8 Gb/s Fibre Channel and two 8 Gb/s FICON Front-End I/O Modules. Information about 8 Gb/s Fibre Channel hardware
components is on page 40. Information about 8 Gb/s FICON hardware components is on page 43.

EE EE
EF-7G EF EF EF-8G
8 FC / 4 FICON engine FA-7F FA FA FA-8F
FA-7E FA FA FA-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 G1 E0 E1 F0 F1 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

EE EE
EF-7G EF EF EF-8G
4 FICON / 4 FC / 2 FC SRDF engine RF-7F RF RF RF-8F
FA-7E FA FA FA-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 F0 G0 G1 E0 E1 F0 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

EE EE
EF-7G EF EF EF-8G
4 FICON / 4 FC SRDF engine RF-7F RF RF RF-8F
RF-7E RF RF RF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 F0 G0 G1 E0 F0 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001706

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 61
EMC CONFIDENTIAL

Mixed 16 Gb/s Fibre Channel and FICON Front-End Configurations


Two 16 Gb/s Fibre Channel and two 8 Gb/s FICON Front-End I/O Modules. Information about 16 Gb/s Fibre Channel
hardware components is on page 41. Information about 8 Gb/s FICON hardware components is on page 43.

EE EE
EF-7G EF EF EF-8G
4 FC / 4 FICON engine FS-7F FS FS FS-8F
FS-7E FS FS FS-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 F0 G0 G1 E0 F0 G0 G1 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
16Gb_FC_FICON

62 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Mixed 8 Gb/s Fibre Channel and GbE with iSCSI, FCoE or SRDF Front-End
Configurations
Two 8 Gb/s Fibre Channel and two GbE Front-End I/O Modules. Information about 8 Gb/s Fibre Channel hardware
components is on page 40. FCoE and iSCSI is provided on 10 GbE I/O Modules. FCoE is not available on 1 GbE I/O modules.
Information about GbE components is on page 45 and page 46.

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
8 FC / 4 iSCSI or FCoE engine FA-7F FA FA FA-8F
FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 H0 E0 E1 F0 F1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
8 FC SRDF / 2 iSCSI or FCoE / 2 SRDF engine FA-7F FA FA FA-8F
FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
E0 E1 F0 F1 G0 H0 E0 E1 F0 F1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
4 FC / 2 FC SRDF / 4 iSCSI or FCoE engine RF-7F RF RF RF-8F
FA-7E FA FA FA-8E
Even director Odd director DA-7D DA DA DA-8D
E0 E1 F0 G0 H0 E0 E1 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-001707

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 63
EMC CONFIDENTIAL

Mixed 16 Gb/s Fibre Channel & GbE with iSCSI, FCoE or SRDF Front-End
Configurations
Two 16 Gb/s Fibre Channel and two GbE Front-End I/O Modules. Information about 16 Gb/s Fibre Channel hardware
components is on page 41. FCoE and iSCSI is provided on 10 GbE I/O Modules. FCoE is not available on 1 GbE I/O modules.
Information about GbE components is on page 45 and page 46.

SE/FE-7H SE/FE SE/FE SE/FE-8H


SE/FE-7G SE/FE SE/FE SE/FE-8G
4 FC / 4 iSCSI or FCoE engine FS-7F FS FS FS-8F
FS-7E FS FS FS-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

RE-7H RE RE RE-8H
SE/FE-7G SE/FE SE/FE SE/FE-8G
4 FC / 2 iSCSI or FCoE / 2 SRDF engine FS-7F FS FS FS-8F
FS-7E FS FS FS-8E
Even director Odd director DA-7D DA DA DA-8D
E0 F0 G0 H0 E0 F0 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
16Gb_FC_GbE

64 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Mixed FICON and GbE with iSCSI, FCoE or SRDF Front-End Configurations
Two 8 Gb/s FICON and two GbE Front-End I/O Modules. Information about 8 Gb/s FICON hardware components is on
page 43. FCoE and iSCSI is provided on 10 GbE I/O Modules. FCoE is not available on 1 GbE I/O modules. Information about
GbE components is on page 45 and page 46.

SE-7H SE /FE SE /FE SE-8H


SE-7G SE /FE SE /FE SE-8G
4 FICON / 4 iSCSI or FCoE engine EE EE
EF-7E EF EF EF-8E
Even director Odd director
DA-7D DA DA DA-8D
E0 E1 E1 G0 H0 E0 E1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even

SE-7H RE RE SE-8H
SE-7G SE /FE SE /FE SE-8G
4 FICON / 2 iSCSI or FCoE / 2 SRDF engine EE EE
EF-7E EF EF EF-8E
Even director Odd director DA DA DA-8D
DA-7D
E0 E1 G0 H0 E0 E1 G0 H0 DA-7C DA DA DA-8C
I/O module slot 4 I/O module slot 5 I/O module
E1 slot 4 I/O module slot 5 DA-7B DA DA DA-8B
DA-7A DA DA DA-8A
Odd Even
SYM-002076

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 65
EMC CONFIDENTIAL

8 Gb/s Fibre Channel with Federated Tiered Storage (FTS) Front-End Options
Four 8 Gb/s Fibre Channel Front-End I/O Modules. Information about 8 Gb/s Fibre Channel hardware components is on
page 40.

4 DX / 12 FC engine 12 DX / 4 FC engine
FA-7H FA FA FA-8H Even director Odd director FA-7H FA FA FA-8H
Even director Odd director FA-7G FA FA FA-8G DX-7G DX DX DX-8G
E0 E1 F0 F1 G0 G1 H0 H1 E0 E1 F0 F1 G0 G1 H0 H1 FA-7F FA FA FA-8F E0 E1 F0 F1 G0 G1 H0 H1 E0 E1 F0 F1 G0 G1 H0 H1 DX-7F DX DX DX-8F
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DX-7E DX DX DX-8E
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DX-7E DX DX DX-8E
DA-7D DA DA DA-8D DA-7D DA DA DA-8D
DA-7C DA DA DA-8C DA-7C DA DA DA-8C
DA-7B DA DA DA-8B DA-7B DA DA DA-8B
DA-7A DA DA DA-8A DA-7A DA DA DA-8A
Odd Even Odd Even
8 DX / 8 FC engine 16 DX engine
FA-7H FA FA FA-8H DX-7H DX DX DX-8H
Even director Odd director Even director Odd director
FA-7G FA FA FA-8G DX-7G DX DX DX-8G
E0 E1 F0 F1 G0 G1 H0 H1 E0 E1 F0 F1 G0 G1 H0 H1 DX-7F DX DX DX-8F E0 E1 F0 F1 G0 G1 H0 H1 E0 E1 F0 F1 G0 G1 H0 H1 DX-7F DX DX DX-8F
I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DX-7E DX DX DX-8E I/O module slot 4 I/O module slot 5 I/O module slot 4 I/O module slot 5 DX-7E DX DX DX-8E
DA-7D DA DA DA-8D DA-7D DA DA DA-8D
DA-7C DA DA DA-8C DA-7C DA DA DA-8C
DA-7B DA DA DA-8B DA-7B DA DA DA-8B
DA-7A DA DA DA-8A DA-7A DA DA DA-8A
Odd Even Odd Even

SYM-001705_dx

66 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
Cabling
EMC CONFIDENTIAL

Engine 4 Back-End Cabling — Directors 7 and 8 — Rear View


System bay Storage bay 1A

Engine 8
DAE 3 LCCB (P1)
DAE 7 LCCB (P2)
DAE 4 LCCB (P3) Engine 7
DAE 8 LCCB (P4)

DAE 1 LCCA (P1) Engine 6


DAE 5 LCCA (P2)
DAE 2 LCCA (P3)
Engine 5
DAE 6 LCCA (P4)

DAE 1 LCCB (P1) DAE 8

SPS
2B
DAE 5 LCCB (P2) DAE 7

DAE 8

DAE 7

DAE 6

DAE 5
DAE 2 LCCB (P3) DAE 6

SPS
DAE 6 LCCB (P4)

2A
Engine 3 DAE 5
SPS 2B SPS 2A
DAE 3 LCCA (P1)
DAE 4

SPS
1B
DAE 7 LCCA (P2) Engine 2
DAE 3

DAE 4

DAE 3

DAE 2

DAE 1
DAE 4 LCCA (P3)
DAE 8 LCCA (P4) DAE 2

SPS
1A
Engine 1 DAE 1
SPS 1B SPS 1A
15-drive DAE 25-drive DAE
SYM-002091_v2

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 69
EMC CONFIDENTIAL

Engine 5 Back-End Cabling — Directors 9 and 10 — Rear View

System bay Storage bay 1A


DAE 16

SPS
4B
DAE 11 LCCB (P1) Engine 8 DAE 15

DAE 16

DAE 15

DAE 14

DAE 13
DAE 15 LCCB (P2)
DAE 14
DAE 12 LCCB (P3)

SPS
DAE 13

4A
DAE 16 LCCB (P4) Engine 7
SPS 4B SPS 4A
DAE 9 LCCB (P1) DAE 12

SPS
3B
Engine 6
DAE 13 LCCB (P2) DAE 11

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 LCCB (P3) DAE 10

SPS
DAE 14 LCCB (P4) DAE 9

3A
SPS 3B SPS 3A
DAE 9 LCCA (P1)
DAE 13 LCCA (P2) Engine 4
DAE 10 LCCA (P3)
DAE 14 LCCA (P4)
Engine 3
DAE 11 LCCA (P1)
DAE 15 LCCA (P2)
DAE 12 LCCA (P3) Engine 2
DAE 16 LCCA (P4)

Engine 1

15-drive DAE 25-drive DAE


SYM-002092_v2

70 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Engine 3 Back-End Cabling — Directors 5 and 6 — Rear View

Storage bay 1B System bay

Engine 8
DAE 3 LCCA (P1)
DAE 7 LCCA (P2)
DAE 4 LCCA (P3) Engine 7
DAE 8 LCCA (P4)

DAE 3 LCCB (P1) Engine 6


DAE 7 LCCB (P2)
DAE 4 LCCB (P3)
Engine 5
DAE 8 LCCB (P4)

DAE 8 DAE 1 LCCB (P1)

SPS
2B
Engine 4
DAE 7 DAE 5 LCCB (P2)
DAE 8

DAE 7

DAE 6

DAE 5
DAE 6 DAE 2 LCCB (P3)
SPS
DAE 6 LCCB (P4)
2A
DAE 5
SPS 2B SPS 2A
DAE 1 LCCA (P1)
DAE 4
SPS
1B

DAE 5 LCCA (P2) Engine 2


DAE 3
DAE 4

DAE 3

DAE 2

DAE 1

DAE 2 LCCA (P3)


DAE 2 DAE 6 LCCA (P4)
SPS
1A

DAE 1 Engine 1
SPS 1B SPS 1A
SYM-002093_v2
25-drive DAE 15-drive DAE

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 71
EMC CONFIDENTIAL

Engine 6 Back-End Cabling — Directors 11 and 12 — Rear View

Storage bay 1B System bay


DAE 16

SPS
4B
DAE 15 DAE 11 LCCB (P1) Engine 8

DAE 16

DAE 15

DAE 14

DAE 13
DAE 14 DAE 15 LCCB (P2)
DAE 12 LCCB (P3)

SPS
DAE 13

4A
DAE 16 LCCB (P4) Engine 7
SPS 4B SPS 4A
DAE 12 DAE 9 LCCB (P1)

SPS
3B
DAE 11 DAE 13 LCCB (P2)

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 DAE 10 LCCB (P3)

SPS
DAE 9 DAE 14 LCCB (P4)

3A
Engine 5
SPS 3B SPS 3A
DAE 11 LCCA (P1)
DAE 15 LCCA (P2) Engine 4
DAE 12 LCCA (P3)
DAE 16 LCCA (P4)
Engine 3
DAE 9 LCCA (P1)
DAE 13 LCCA (P2)
DAE 10 LCCA (P3) Engine 2
DAE 14 LCCA (P4)

Engine 1

25-drive DAE 15-drive DAE SYM-002094_v2

72 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Engine 2 Back-End Cabling — Directors 3 and 4 — Rear View

Storage bay 1C
System bay

Engine 8 DAE 1 LCCB (P1)


DAE 5 LCCB (P2)
DAE 2 LCCB (P3)
Engine 7 DAE 6 LCCB (P4)

Engine 6 DAE 3 LCCB (P1)


DAE 7 LCCB (P2)
DAE 4 LCCB (P3)
Engine 5 DAE 8 LCCB (P4)

DAE 3 LCCA (P1)


DAE 8

SPS
DAE 7 LCCA (P2)

2B
Engine 4 DAE 7

DAE 8

DAE 7

DAE 6

DAE 5
DAE 4 LCCA (P3)
DAE 6
DAE 8 LCCA (P4)

SPS
DAE 5

2A
Engine 3
SPS 2B SPS 2A

DAE 4

SPS
1B
DAE 1 LCCA (P1) DAE 3

DAE 4

DAE 3

DAE 2

DAE 1
DAE 5 LCCA (P2)
DAE 2
DAE 2 LCCA (P3)

SPS
1A
Engine 1 DAE 1
DAE 6 LCCA (P4)
SPS 1B SPS 1A
15-drive DAE 25-drive DAE
SYM-002095_v2

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 73
EMC CONFIDENTIAL

Engine 7 Back-End Cabling — Directors 13 and 14 — Rear View

System bay Storage bay 1C


DAE 16

SPS
4B
DAE 9 LCCB (P1) Engine 8 DAE 15

DAE 16

DAE 15

DAE 14

DAE 13
DAE 13 LCCB (P2) DAE 14
DAE 10 LCCB (P3)

SPS
DAE 13

4A
DAE 14 LCCB (P4)
SPS 4B SPS 4A
DAE 9 LCCA (P1) DAE 12

SPS
3B
Engine 6
DAE 13 LCCA (P2) DAE 11

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 LCCA (P3) DAE 10

SPS
DAE 14 LCCA (P4) DAE 9

3A
Engine 5
SPS 3B SPS 3A
DAE 11 LCCA (P1)
DAE 15 LCCA (P2) Engine 4
DAE 12 LCCA (P3)
DAE 16 LCCA (P4)
Engine 3
DAE 11 LCCB (P1)
DAE 15 LCCB (P2)
DAE 12 LCCB (P3) Engine 2
DAE 16 LCCB (P4)

Engine 1

15-drive DAE 25-drive DAE


SYM-002096_v2

74 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Engine 1 Back-End Cabling — Directors 1 and 2 — Rear View

Storage bay 1D System bay

DAE 3 LCCB (P1) Engine 8


DAE 7 LCCB (P2)
DAE 4 LCCB (P3)
DAE 8 LCCB (P4) Engine 7

DAE 3 LCCA (P1)


Engine 6
DAE 7 LCCA (P2)
DAE 4 LCCA (P3)
DAE 8 LCCA (P4)
Engine 5

DAE 1 LCCB (P1)


DAE 8

SPS
DAE 5 LCCB (P2)

2B
DAE 7 DAE 8 Engine 4

DAE 7

DAE 6

DAE 5
DAE 2 LCCB (P3)
DAE 6
DAE 6 LCCB (P4)

SPS
DAE 5 2A Engine 3
SPS 2B SPS 2A DAE 1 LCCA (P1)
DAE 4 DAE 5 LCCA (P2)
SPS
1B

DAE 2 LCCA (P3) Engine 2


DAE 3
DAE 4

DAE 3

DAE 2

DAE 1
DAE 6 LCCA (P4)
DAE 2
SPS

DAE 1
1A

SPS 1B SPS 1A
25-drive DAE 15-drive DAE SYM-002097_v2

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 75
EMC CONFIDENTIAL

Engine 8 Back-End Cabling — Directors 15 and 16 — Rear View


Storage bay 1D System bay
DAE 16

SPS
4B
DAE 15 DAE 9 LCCB (P1)

DAE 16

DAE 15

DAE 14

DAE 13
DAE 13 LCCB (P2)
DAE 14
DAE 10 LCCB (P3)

SPS
DAE 13

4A
DAE 14 LCCB (P4) Engine 7
SPS 4B SPS 4A

DAE 12 DAE 9 LCCA (P1)

SPS
3B
Engine 6
DAE 11 DAE 13 LCCA (P2)

DAE 12

DAE 11

DAE 10

DAE 9
DAE 10 DAE 10 LCCA (P3)

SPS
DAE 9 DAE 14 LCCA (P4)

3A
Engine 5
SPS 3B SPS 3A
DAE 11 LCCA (P1)
DAE 15 LCCA (P2) Engine 4
DAE 12 LCCA (P3)
DAE 16 LCCA (P4)
Engine 3
DAE 11 LCCB (P1)
DAE 15 LCCB (P2)
DAE 12 LCCB (P3) Engine 2
DAE 16 LCCB (P4)

Engine 1

SYM-002098
25-drive DAE 15-drive DAE

76 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Fabric (MIBE-SIB) Cabling — Rear View

SIB1 SIB2

B A B A

Dir 9 Dir 11 Dir 13 Dir 15 Dir 1 Dir 3 Dir 5 Dir 7 Dir 16


SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B Dir 15
Dir 10 Dir 12 Dir 14 Dir 16 Dir 2 Dir 4 Dir 6 Dir 8
SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B SIB 2B Dir 14
MIBE 2B MIBE 2A Dir 13

0 2 4 6 8 101214 0 2 4 6 8 101214
1 3 5 7 9 111315 1 3 5 7 9 111315
Dir 12
Engine 6 Dir 11
Dir 9 Dir 11 Dir 13 Dir 15 Dir 1 Dir 3 Dir 5 Dir 7
SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A
Dir 10
Dir 10 Dir 12 Dir 14 Dir 16 Dir 2 Dir 4 Dir 6 Dir 8 Engine 5 Dir 9
SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A SIB 2A

Dir 8 Dir 9 Dir 11 Dir 13 Dir 15 Dir 1 Dir 3 Dir 5 Dir 7


Engine 4 Dir 7 SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B
Dir 10 Dir 12 Dir 14 Dir 16 Dir 2 Dir 4 Dir 6 Dir 8
SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B SIB 1B
Dir 6
Engine 3 Dir 5 MIBE 1B MIBE 1A

0 2 4 6 8 101214 0 2 4 6 8 101214
1 3 5 7 9 111315 1 3 5 7 9 111315
Dir 4
Dir 3
Dir 9 Dir 11 Dir 13 Dir 15 Dir 1 Dir 3 Dir 5 Dir 7
Dir 2 SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A
Dir 1 Dir 10 Dir 12 Dir 14 Dir 16 Dir 2 Dir 4 Dir 6 Dir 8
SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A SIB 1A

Fabric_Cabling
System bay (rear)

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 77
EMC CONFIDENTIAL

Management Module Ethernet Cabling, 1- & 2-Engine — Rear View

1-Engine 2-Engine

Engine 5
Server Server
KVM KVM

Engine 4 Engine 4

Ethernet_1_2

78 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Management Module Ethernet Cabling, 3- & 4-Engine — Rear View

3-Engine 4-Engine

Engine 6

Engine 5 Engine 5
Server Server
KVM KVM

Engine 4 Engine 4

Engine 3 Engine 3

Ethernet_3_4

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 79
EMC CONFIDENTIAL

Management Module Ethernet Cabling, 5- & 6-Engine — Rear View

5-Engine 6-Engine

Engine 7

Engine 6 Engine 6

Engine 5 Engine 5
Server Server
KVM KVM

Engine 4 Engine 4

Engine 3 Engine 3

Engine 2 Engine 2

Ethernet_5_6

80 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Management Module Ethernet Cabling, 7- & 8-Engine — Rear View

7-Engine 8-Engine

Engine 8

Engine 7 Engine 7

Engine 6 Engine 6

Engine 5 Engine 5
Server Server
KVM KVM

Engine 4 Engine 4

Engine 3 Engine 3

Engine 2 Engine 2

Engine 1 Engine 1
Ethernet_7_8

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 81
EMC CONFIDENTIAL

Management Module Ethernet Cabling, Dispersed at Third Engine — Rear View

System bay 1 System bay 2 System bay 1 System bay 2 System bay 1 System bay 2
2/1 2/2 2/3
UPS UPS
UPS

Engine 6 Engine 6

Engine 5 Engine 5 Engine 5


Server Server Server Server
Server Server
KVM KVM KVM KVM KVM KVM

Engine 4 Engine 4 Engine 4

Engine 3 Engine 3 Engine 3

Engine 2

SYM-002651_qs SYM-002652_qs SYM-002653_qs

82 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Management Module Ethernet Cabling, Dispersed at Third Engine — Rear View

System bay 1 System bay 2 System bay 1 System bay 2 System bay 1 System bay 2
2/4 2/5 2/6
UPS UPS UPS

Engine 8

Engine 7 Engine 7 Engine 7

Engine 6 Engine 6 Engine 6

Engine 5 Engine 5 Engine 5


Server Server Server Server Server Server
KVM KVM KVM KVM KVM KVM

Engine 4 Engine 4 Engine 4

Engine 3 Engine 3 Engine 3

Engine 2 Engine 2 Engine 2

Engine 1 Engine 1

SYM-002654_qs SYM-002655_qs SYM-002656_qs

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 83
EMC CONFIDENTIAL

Management Module Ethernet Cabling, Dispersed at Fifth Engine — Rear View

System bay 1 System bay 2 System bay 1 System bay 2


4/1 4/2
UPS UPS

Engine 7

Engine 6 Engine 6

Engine 5 Engine 5
Server Server Server Server
KVM KVM KVM KVM

Engine 4 Engine 4

Engine 3 Engine 3

Engine 2 Engine 2

SYM-002657_qs SYM-002658_qs

84 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Management Module Ethernet Cabling, Dispersed at Fifth Engine — Rear View

System bay 1 System bay 2 System bay 1 System bay 2


4/3 4/4
UPS UPS

Engine 8

Engine 7 Engine 7

Engine 6 Engine 6

Engine 5 Engine 5
Server Server Server Server
KVM KVM
KVM KVM

Engine 4 Engine 4

Engine 3 Engine 3

Engine 2 Engine 2

Engine 1 Engine 1

SYM-002660_qs
SYM-002659_qs

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 85
EMC CONFIDENTIAL

Management Module Ethernet Cabling, Dispersed at Seventh Engine — Rear View

System bay 1 System bay 2 System bay 1 System bay 2


7/1 7/2
UPS UPS

Engine 8

Engine 7 Engine 7

Engine 6 Engine 6

Engine 5 Engine 5
Server Server Server Server
KVM KVM KVM KVM

Engine 4 Engine 4

Engine 3 Engine 3

Engine 2 Engine 2

Engine 1 Engine 1

SYM-002661_qs SYM-002662_qs

86 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

System Bay 1 RS-232 Cabling, SPS, UPS & MIBE — Rear View

UPS RS-232 Cabling


From RESET port on UPS panel
to Engine 4’s Managment Module B
UPS Extension Panel
management port
038-004-052
ON
RESET
I
ON
ON
I
ON
I
I O
O OFFO
OFFO OFF
OFF

ON
ON I
ON
I
ON I
I O
O OFFO
OFFO OFF
OFF

ON
ON I
ON
I
ON I
I O
O OFFO
OFFO OFF
OFF

MIBE RS-232 Cabling


038-003-594

038-003-682
038-003-682
SPS B-side RS-232 Sense Cabling SPS A-side RS-232 Sense Cabling
per Engine per Engine

System bay (rear)


RS232_40K

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 87
EMC CONFIDENTIAL

88 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
Part Numbers
EMC CONFIDENTIAL

Main Components

Table 8 Main Componenta (Sheet 1 of 4)

Part
Name number Notes

#1 Engine cooling fan 045-000-204 Air mover module, 24 V input

#2 Power distribution unit (PDU) 100-885-137 A single part number for all power configurations

#3 Power distribution panel (PDP) 100-885-140 Three-phase WYE PDP

#4 Power distribution panel (PDP) 100-885-139 Three-phase DELTA PDP

#5 Power distribution panel (PDP) 100-885-138 Single-phase PDP

#6 Standard DAE 100-886-019 Empty 15-drive DAE chassis with midplane


Standard DAE link control card
#7 303-127-000A For 3.5 drives
(LCC)
Standard DAE power supply/ 071-000-508
#8 Dual +12V, hot-plug, 400W 1U, for 15-drive DAEs
cooling module 071-000-535
#9 Engine power supply 071-000-540

#10 MIBE power supply/cooling module 071-000-521 Replaced from the front

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 91
EMC CONFIDENTIAL

Table 8 Main Componenta (Sheet 2 of 4)

Part
Name number Notes

Standby power supply (SPS) 078-000-050


078-000-086 FRU for 078-000-050 is 078-000-051
#11
Lithium-Ion SPS 078-000-080 Lithium-Ion SPS tray
078-000-082 Lithium-Ion SPS battery for 078-000-080

#12 Front door USB AC adapter 071-000-521 Powers front door blue LED assembly in storage bays

#13 UPS 078-000-052 350W power supply for the Server, FRU is 078-000-053
090-000-218 Intel IU server, Feldman (main)
#14 Server
090-000-221 Intel IU server, Feldman (remote service processor)

#15 KVM 091-000-091 Emerson KVM

#16 Modem (optional) 100-602-106


4 GB cache memory module 100-562-866
8 GB cache memory module 100-562-479 Serialized memory modules, replaced in pairs, used in Cache
#17
16 GB cache memory module 100-562-456 Memory Module replacement kits.
32 GB cache memory module 100-563-491

#18 MIBE assembly 100-886-914 MIBE without power supply/cooling module

#19 Management Module 303-132-000C

92 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Table 8 Main Componenta (Sheet 3 of 4)

Part
Name number Notes

#20 System Interface Board (SIB) 303-186-100A

#21 I/O Module carrier 303-145-000B No hardware compression


I/O Module carrier with
#22 303-165-000B Used only with GbE SRDF Front-End I/O Modules
compression
303-128-111B Director without Cache Memory Modules
#23 Director
100-563-451 eFlash (ordered and replaced when Director board is replaced)
Fibre Channel Back End I/O
#24 303-086-101B 4 Gb Fibre Channel 4-port SFP
Module
Fibre Channel Back End I/O
#25 303-176-100B 4 Gb Fibre Channel 4-port SFP with encryption
Module with encryption

#26 High density DAE 100-886-122 Empty 25-drive DAE chassis


100-886-936 For system bay and 15-drive DAE storage bays
#27 Front door light bar
100-563-541 For 25-drive DAE storage bays
GbE iSCSI/SRDF Front-End I/O
#28 303-950-100C 1 GbE iSCSI 2-port SFP
Module
GbE iSCSI/FCoE SRDF Front-End
#29 303-142-100A 10 GbE iSCSI/FCoE 2-port SFP
I/O Module
Fibre Channel Front-End I/O
#30 303-092-102B 8 Gb/s Fibre Channel 4-port SFP
Module

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 93
EMC CONFIDENTIAL

Table 8 Main Componenta (Sheet 4 of 4)

Part
Name number Notes

#31 FICON Front-End I/O Module 303-120-100B 8 Gb/s FICON 2-port SFP
High density DAE power supply/
#32 071-000-541 For 2.5 inch drives
cooling module
High density DAE link control card
#33 303-230-000B For 2.5 inch drives
(LCC)

#34 SFP+ MM ports, 2/4/8 Gb 019-078-042

#35 SFP+ SM ports, 2/4/8 Gb 019-078-043

#36 SFP+ MM ports, 10 Gb 019-078-041 10 Gb/s GbE iSCSI/FCoE 2-port SFP

#37 System bay 1 server panel 100-886-150 For system bay 1 only
16 Gb/s Fibre Channel Front-End I/
#38 303-235-101
O Module
For 16 Gb/s Fibre Channel Front-End I/O Module
Small form-factor pluggable 019-078-045
#39
transceiver (MM)

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

94 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

Ethernet Cables and Cable Bundles

Table 9 Ethernet cables and cable bundlesa

Name Part
number
Notes
71 inches/ 1.80 meters 038-003-676 Purple
038-003-886 Green
20 inches/.50 meters 038-003-678 Purple
038-003-679 Green
98.4 feet/.30 meters 038-003-680 Purple
038-003-681 Green
98.4 feet/30 meters 038-004-226 Green/gray
98.4 feet/30 meters 038-004-227 Purple/gray

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 95
EMC CONFIDENTIAL

Back-End Cables
Table 10 Back-end cablesa

Part
Name number Notes
038-003-706
QSFP to 4 HSSDC2 Direct-connect cable, 4.5 meters/177.16 inches
038-004-253
QSFP to 4 HSSDC2 038-004-253 Direct-connect cable, 25-drive DAEs only
HSSDC2 to HSSDC2 038-003-510 Daisy-chain cable, 4 meters/157.48 inches
HSSDC2 to HSSDC2 038-003-572 Daisy-chain, separated storage bay cable,10 meters/393.7 inches

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

96 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

SIB to MIBE Copper Cables (Standard Layout)


Table 11 SIB to MIBE Copper Cablesa (Sheet 1 of 2)

Name Part
number
Notes
31 inches/0.79 meters 038-004-053 Dir 12/SIB B to MIBE B port 3
Dir 11/SIB A to MIBE A port 2
Dir 11/SIB B to MIBE B port 2
Dir 12/SIB A to MIBE A port 3
34 inches/0.86 meters 038-004-054
Dir 13/SIB B to MIBE B port 4
Dir 14/SIB B to MIBE B port 5
Dir 16/SIB A to MIBE A port 7
41 inches/1.04 meters 038-004-055 Dir 9/SIB A to MIBE A port 0
Dir 5/SIB A to MIBE A port 12
52 inches/1.32 meters 038-004-057
Dir 6/SIB A to MIBE A port 13
Dir 6/SIB B to MIBE B port 13
60 inches/1.52 meters 038-004-058 Dir 7/SIB B to MIBE B port 14
Dir 8/SIB B to MIBE B port 15
Dir 3/SIB A to MIBE A port 10
68 inches/1.73 meters 038-004-060
Dir 5/SIB B to MIBE B port 12
Dir 7/SIB A to MIBE A port 14
Dir 8/SIB A to MIBE A port 15
46 inches/1.17 meters 038-004-056
Dir 15/SIB B to MIBE B port 6
Dir 16/SIB B to MIBE B port 7

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 97
EMC CONFIDENTIAL

Table 11 SIB to MIBE Copper Cablesa (Sheet 2 of 2)

Name Part
number
Notes
63 inches/1.6 meters 038-004-059 Dir 4/SIB A to MIBE A port 11
Dir 1/SIB A to MIBE A port 8
Dir 2/SIB A to MIBE A port 9
72 inches/1.83 meters 038-004-061
Dir 3/SIB B to MIBE B port 10
Dir 4/SIB B to MIBE B port 11
Dir 1/SIB B to MIBE B port 8
85 inches/2.16 meters 038-004-062
Dir 2/SIB B to MIBE B port 9
Dir 9/SIB B to MIBE B port 0Dir 10/SIB A to MIBE A port 1
Dir 10/SIB B to MIBE B port 1
Dir 13/SIB A to MIBE A port 4
Dir 14/SIB A to MIBE A port 5
39.37 inches /1 meter 038-004-072 Dir 15/SIB A to MIBE A port 6
Dir 8/SIB A to MIBE A port 15
Dir 7/SIB B to MIBE B port 14
Dir 8/SIB B to MIBE B port 15

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

98 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide
EMC CONFIDENTIAL

SIB to MIBE Optical Cable Bundles and QSFP (Dispersed Layouts)

Table 12 Optical cable bundlesa

Name Part
number
Notes
038-004-190
Optical cable bundle/30 meters White sheathing
038-004-198
038-004-191
Optical cable bundle/30 meters Blue sheathing
038-004-199
038-004-193
Optical cable bundle/30 meters Purple sheathing
038-004-201
038-004-194
Optical cable bundle/30 meters Red sheathing
038-004-202
038-004-196
Optical cable bundle/30 meters Orange sheathing
038-004-204
038-004-197
Optical cable bundle/30 meters Pink sheathing
038-004-205
QSFP Optical Module 019-078-044

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide 99
EMC CONFIDENTIAL

RS-232 Sense Cables


Table 13 RS-232 Sense Cables a

Part
RS-232 cable type number Notes
MIBE to MIBE 038-003-594

UPS to Management Module 038-004-052

System bay SPS to Management Module 038-003-682 12 inches/0.30 meters

a. The most recent part information is available on MyGSIntranet, in the Parts Compatibility Database.

100 EMC Symmetrix VMAX 40K Series Customer Service Quick Reference Guide