CSQRG_987

The document is a Customer Service Quick Reference Guide for the EMC® Symmetrix® VMAX® 10K Series, detailing system and storage bay components, configurations, and cabling. It includes diagrams and part numbers for various components, as well as information on system layout and configurations for standard and high-density DAEs. The publication is intended for use by customer service personnel and is marked as EMC confidential.

Uploaded by

tachyon.20230417
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
8 views

CSQRG_987

The document is a Customer Service Quick Reference Guide for the EMC® Symmetrix® VMAX® 10K Series, detailing system and storage bay components, configurations, and cabling. It includes diagrams and part numbers for various components, as well as information on system layout and configurations for standard and high-density DAEs. The publication is intended for use by customer service personnel and is marked as EMC confidential.

Uploaded by

tachyon.20230417
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 81

EMC CONFIDENTIAL

EMC® Symmetrix®

VMAX® 10K Series (SN-xxx987xxxxx)

Customer Service Quick Reference Guide


November 10, 2014
REV 06

EMC Corporation
Hopkinton, MA 01748-9103
1-508-435-1000 (in North America) 1-866-464-7381
www.EMC.com
EMC CONFIDENTIAL

Copyright © 2012 - 2014 EMC Corporation. All rights reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without
notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS
OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY
DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.
For the most up-to-date regulatory document for your product line, go to EMC Online Support http://support.EMC.com.

For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com.

All other trademarks used herein are the property of their respective owners.

2 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table of Contents
System and Storage Bay Components .................................................................................................................................................................. 7
System Bay Components ...................................................................................................................................................................................9
Storage Bay Components .................................................................................................................................................................................10
VMAX 10K File Components, All Standard and Mixed DAEs ...........................................................................................................................11
VMAX 10K File Components, High Density DAEs ............................................................................................................................................12
Engine Components — Front and Rear View ...................................................................................................................................................13
Server — Rear View .........................................................................................................................................................................................14
UPS — Front and Rear View ............................................................................................................................................................................15
Data Mover — VMAX 10K File Systems, Rear View .......................................................................................................................................16
Control Station — VMAX 10K File Systems, Rear View ...................................................................................................................................17
MIBE Components — Front and Rear View .....................................................................................................................................................18
Standard (15-Drive) DAE, Components and Chassis — Rear View .................................................................................................................19
High Density (25-Drive) DAE, Components and Chassis .................................................................................................................................20
System Layout ..................................................................................................................................................................................................... 21
Single System Bay configurations, All Standard and Mixed DAEs ...................................................................................................................23
Single System Bay configuration, All High Density DAEs .................................................................................................................................24
Four System Bays, maximum All Standard DAE configuration, 960 Drives .....................................................................................................25
Four System Bays, dispersed, maximum All Standard DAE configuration, 960 Drives ....................................................................................26
Four System Bays, maximum All High Density DAE configuration, 1200 Drives .............................................................................................27
Four System Bays, dispersed, maximum All High Density DAE configuration, 1200 Drives ............................................................................28
Engine Components............................................................................................................................................................................................. 29
Engine Power Supply/Cooling Modules — Front View .....................................................................................................................................31
Management Modules — Rear View ................................................................................................................................................................32
System Interface Boards (SIB) and Connections — Rear View .......................................................................................................................33
Fibre Channel Back End I/O Modules, Slots and Ports — Rear View ..............................................................................................................34
4 and 8 Gb/s Fibre Channel Front-End I/O Modules, Slots and Ports — Rear View ........................................................................................35

Customer Service Quick Reference Guide 3


EMC CONFIDENTIAL

16 Gb/s Fibre Channel Front End I/O Module, Slots and Ports — Rear View ..................................................................................................36
4 Gb/s Fibre Channel Front-End I/O Modules, Components — AP only ..........................................................................................................37
8 Gb/s Fibre Channel Front-End I/O Module, Components ..............................................................................................................................38
16 Gb/s Fibre Channel Front End I/O Module, Components ............................................................................................................................39
GbE with iSCSI/FCoE or SRDF Front-End I/O Modules, Slots and Ports — Rear View ..................................................................................40
GbE with iSCSI/FCoE or SRDF Front-End I/O Modules, Components ............................................................................................................41
Director .............................................................................................................................................................................................................42
LED Indicators ..................................................................................................................................................................................................43
Front-End Configurations ..................................................................................................................................................................................... 47
4 Gb/s Fibre Channel Front-End Options — AP only .......................................................................................................................................49
8 Gb/s Fibre Channel Front-End Options .........................................................................................................................................................50
16 Gbs Fibre Channel Front End Options .........................................................................................................................................................51
GbE with iSCSI/FCoE and SRDF Front-End Options — AP only .....................................................................................................................52
GbE with iSCSI/FCoE and SRDF Front-End Options .......................................................................................................................................53
Mixed Fibre Channel and GbE with iSCSI/FCoE and SRDF Front-End Options ..............................................................................................54
Mixed 16 Gb/s Fibre Channel and GbE with iSCSI/FCoE and SRDF Front End Options ................................................................................55
8 Gb/s Fibre Channel with Federated Tiered Storage Front-End Options ........................................................................................................56
Cabling ................................................................................................................................................................................................................. 57
Engine Power Supply/Cooling Module Power Zones & Engine AC Cabling .....................................................................................................59
Management Module Ethernet Cabling, One System Bay — Rear View .........................................................................................................60
Management Module Ethernet Cabling, Two System Bays — Rear View .......................................................................................................61
Management Module Ethernet Cabling, Three System Bays — Rear View .....................................................................................................62
Management Module Ethernet Cabling, Four System Bays — Rear View .......................................................................................................63
Management Module Ethernet Cabling, Dispersed Bays — Rear View ...........................................................................................................64
System Bay 1 RS-232 Sense Cables, SPS & UPS — Rear View ....................................................................................................................65
System Bay 2, 3 & 4 RS-232 Sense Cables, SPS — Rear View .....................................................................................................................66
Fabric (MIBE-SIB) Copper Cabling — Rear View .............................................................................................................................................67
Fabric Optical Cabling, Dispersed System Layout — Rear View .....................................................................................................................68
Standard DAE Back-End Cabling, Direct ..........................................................................................................................................................69

4 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

High Density DAE Back-End Cabling, Direct ....................................................................................................................................................70


Standard or Mixed DAE Back-End Cabling, Storage Bay 1A, Standard or Dispersed System Layout ............................................................71
Standard or Mixed DAE Back-End Cabling, Storage Bay 1B, Standard System Layout ..................................................................................72
High Density Back-End Cabling, Standard or Dispersed System Layout .........................................................................................................73
VMAX 10K File, Fibre Channel Cabling, 1 and 2 Engines ................................................................................................................................74
VMAX 10K File, Fibre Channel Cabling, 3 Engines ..........................................................................................................................................75
VMAX 10K File, Fibre Channel Cabling, 4 Engines ..........................................................................................................................................76
Part Numbers ....................................................................................................................................................................................................... 77
Main Components .............................................................................................................................................................................................79
Back-End Cables ..............................................................................................................................................................................................82
MIBE Cables .....................................................................................................................................................................................................83
Ethernet Cables ................................................................................................................................................................................................84
Power Cables ....................................................................................................................................................................................................85

Customer Service Quick Reference Guide 5


System and Storage Bay Components
EMC CONFIDENTIAL

System Bay Components


System Bay 1 System Bay 2 System Bay 3, 4
Includes Server, KVM and UPS Includes MIBE

B
A

B
A

ON ON ON ON ON ON
I I I I I I
O O O O O O
OFF OFF OFF OFF OFF OFF

Standard, Standard, Standard, Standard, Standard,


B
A

Standard,
Mixed, or Mixed, or Mixed, or Mixed, or Mixed, or Mixed, or
High density ON
I
O
OFF
High density ON
I
O
OFF
High density ON
I
O
OFF
High density
ON
I
O
OFF
High density
ON
I
O
OFF

High density
ON
I
O
OFF

DAEs: DAEs: DAEs: DAEs: DAEs: DAEs:


5-10 5-10 5-10 5-10 5-10 5-10
PDU ON
I
O
OFF
ON
I
O
OFF
ON
I
O
OFF
ON
I
O
OFF
ON
I
O
OFF
ON
I
O
OFF

#1 PDU PDU
B
A

KVM
#10
Engine Engine Engine

UPS
LAN1
LAN2
#8 ! ! ! !
MIBE
Server
#9 SPS SPS
SPS
#7 B
A

PDP PDP PDP


Standard or #2 Standard or Standard or Standard or Standard or B
Standard or
Mixed DAEs: Mixed DAEs: Mixed DAEs: Mixed DAEs: Mixed DAEs: Mixed DAEs:
1-4 1-4 1-4 1-4 1-4 1-4
High density DAEs: High density DAEs: High density DAEs: High density DAEs: High density DAEs: High density DAEs:
1-4, 31,41 1-4, 31,41 1-4, 31,41 1-4, 31,41 1-4, 31,41 1-4, 31,41
B
A

SPS SPS SPS

Front view Rear view Front view Rear view Front view Rear view
SYM-002577 987 system

Part number information about components #1, #2, #7, #8, #9 and #10 is available in Table 6 on page 79. Part number information for other
components is referenced from the page that shows details about the component.

Customer Service Quick Reference Guide 9


EMC CONFIDENTIAL

Storage Bay Components

Storage Bay (front) Storage Bay (rear)


Storage bays can be added to
Standard or Mixed DAE
system configurations B
A

B
A

PDU B B
PDU A Standard DAE (rear) DAE power supply/
DAEs cooling module B
A

Standard DAE (front) DAEs


7-12 ON
I
7-12 I

!
O
O
OFF

!
B
A

EXP PRI

LCC B

!
#
B EXP PRI

PRI EXP
A #

!
PRI EXP

ON
I
O
OFF
B
I
O

LCC A

!
A

!
0 14
B
ON
I
O
OFF
A I
O

DAE power supply/


Empty cooling module A
Empty

B
A High density DAE (rear)
High density DAE (front) LCC B
0 24
PDP B
B
A PDP A PRI EXP

DAEs B
DAEs A

1-6 1-6
0 24
B
A
DAE power supply/ LCC A DAE power supply/
cooling module B cooling module A
B
A

B
A

IMG-ICO-000865_987_storage bay
Power zone B Power zone A
(left, black) (right, gray)

10 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

VMAX 10K File Components, All Standard and Mixed DAEs

Storage Bay 1A (front) Storage Bay 1A (rear)


Data mover (front) Data mover (rear)
4 5 Blade 5 4

2 3 Blade 3 2
1 Control Station 1
Control Station (front) 0 Control Station 0
Control Station (rear)
Empty PDU ON
I
O
OFF
Empty ON
I
O
OFF
PDU
(to Symmetrix) (to Symmetrix)
DAEs ON
I
O
OFF

B
A
DAEs O
I

7- 8 7-8
ON I
I B O
O
OFF A

Empty PDP PDP


Empty
(to VMAX 10K (to VMAX 10K File
File components) components)
B
A

Lower PDU B
A
Lower PDU
(behind PDP to (behind PDP to
DAEs VMAX10 K file B
DAEs VMAX 10K File
A

1-6 components) 1-6 components)


PDP B
A

PDP
(to Symmetrix) (to Symmetrix)
B
A

B
A

Power zone B Power zone A gateway_bay1a


(left, black) (right, gray)

Customer Service Quick Reference Guide 11


EMC CONFIDENTIAL

VMAX 10K File Components, High Density DAEs

System Bay 1
Includes Server, KVM and UPS

Data mover (front) Data mover (rear)


4 5 5 4

2 3 3 2

Control Station (front)


ON
I
O
OFF
ON
I
O
OFF
Control Station (rear)
PDU PDU
(to Symmetrix) (to Symmetrix)
DAEs ON
I
O
OFF DAEs ON
I
O
OFF

5-10 5-10
PDP
(to VMAX 10K File ON
I
O
OFF
ON
I
O
OFF
PDP
components) (to VMAX 10K File
components)
KVM
Engine
UPS
Server
Lower PDU
LAN1
LAN2

Lower PDU (behind PDP to


(behind PDP to VMAX 10K File
VMAX 10K File components)
components)
DAEs DAEs PDP
PDP
1-41 1-41 (to Symmetrix)
(to Symmetrix)

SPS

Front view Rear view


Power zone B Power zone A gateway_sb1
(left, black) (right, gray)

12 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Engine Components — Front and Rear View

Engine power supply/cooling modules

A0 A1 B0 B1

Even director Odd director


slot slot slot slot slot slot slot slot slot slot
0 1 2 3 4 0 1 2 3 4

SIB Front End SIB Front End


I/O Modules I/O Modules
Management Back End Management Back End
Module B I/O Modules Module A I/O Modules SYM-002578

Customer Service Quick Reference Guide 13


EMC CONFIDENTIAL

Server — Rear View

Ethernet to Management Module A


Modem serial port in system bay 1

PS2 mouse to KVM CS spare port

Power from UPS Video to KVM USB Customer network

PS2 keyboard to KVM Ethernet to Management Module B Server


#9
of the engine in the highest system bay
SYM-002084

Part number information for component #9 is available in Table 6 on page 79.

14 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

UPS — Front and Rear View

UPS Front view


#8 Output
On Line LED Overload LED

On Battery LED Replace


Battery LED

RS-232 Sense cable


Rear view
Management Module B
COM 1 Port 038-003-894

AC Present, AC Present,
UPS_Front_Rear
Main Input LED AUX Input LED

Part number information for component #8 is available in Table 6 on page 79. LED information is available in Table 5 on page 46. Information
on RS-232 sense cabling is provided on page 65.

Customer Service Quick Reference Guide 15


EMC CONFIDENTIAL

Data Mover — VMAX 10K File Systems, Rear View

Management Modules

#33
Data Mover
enclosure
slot 0 slot 0
#34
Data Mover

3 3
2 2
#36
1 1
Four-port FC I/O modules
0 0

slot 0 slot 0

vnx_components

Part number information for components #33, #34, and #36 is available in Table 6 on page 79.

16 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Control Station — VMAX 10K File Systems, Rear View

Rj-45 Ethernet port Rj-45 Ethernet port


(A label) (MGMT label)
AC power in Rj-45 Ethernet port Rj-45 Ethernet port DB-9 serial console
(not used) (B label) plug connector

DB-9 modem 4 - USB connectors


plug connector (not used)

#35 DB-15 VGA connector


Control Station (not used)

Part number information for component #35 is available in Table 6 on page 79.

Customer Service Quick Reference Guide 17


EMC CONFIDENTIAL

MIBE Components — Front and Rear View

Dir 1 Dir 3 Dir 5 Dir 7 Dir 1 Dir 3 Dir 5 Dir 7


MIBE power supply/ SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A
cooling module Dir 2 Dir 4 Dir 6 Dir 8 Dir 2 Dir 4 Dir 6 Dir 8
#14 SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A

MIBE B MIBE A
Port Port Port Port Port Port Port Port
8 10 12 14 8 10 12 14
Port Port Port Port Port Port Port Port
9 11 13 15 9 11 13 15

Port Port Port Port


8 10 12 14
Port Port Port Port
9 11 13 15

MIBE B assembly
#13

MIBE A assembly

SYM-002585

Part number information for components #13 and #14 is available in Table 6 on page 79.

18 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Standard (15-Drive) DAE, Components and Chassis — Rear View

DAE chassis
#3

DAE power supply/


cooling modules LCC B
#5 #4
EXP PRI
port port
!
!

EXP PRI
!

#
B EXP PRI

PRI EXP
A #
!

PRI EXP

!
!
PRI EXP
port port

LCC A SYM-002584

Part number information for components #3, #4, and #5 is available in Table 6 on page 79.

Customer Service Quick Reference Guide 19


EMC CONFIDENTIAL

High Density (25-Drive) DAE, Components and Chassis

DAE power supply/


LCC B DAE chassis
cooling module A #29
B PRI EXP
port port

PRI EXP

B PRI EXP

A
EXP PRI

EXP PRI

EXP PRI A
port port
DAE power supply/
cooling module B LCC A
#31
#30
Rear Front
SYM-002639_987

Part number information for components #29, #30, and #31 is available in Table 6 on page 79.

20 Customer Service Quick Reference Guide


System Layout
EMC CONFIDENTIAL

Single System Bay configurations, All Standard and Mixed DAEs


System Bay 1 System Bay 1
All Standard DAEs Mixed DAEs (example)
(120 drives) (160 drives)

Empty Empty

DAE 8 D1
DAE 8 D1
DAE 7 C1
DAE 7 C1
Vault D0 Vault
DAE 6 DAE 6
D0
Vault C0 Vault
DAE 5 DAE 5 C0
KVM KVM
Engine 1 Engine 1
Dir 1 & 2 Dir 1 & 2
Cable Manager Cable Manager
UPS UPS
Server Server

SPS SPS

B1 Empty
DAE 4
DAE 4 B1
DAE 3 A1 A1
DAE 3

Vault Vault
B0 B0
DAE 2 DAE 2
Vault Vault
A0 A0
DAE 1 DAE 1
SPS SPS

Rear view Config_SingleBay_StandardMixed

Customer Service Quick Reference Guide 23


EMC CONFIDENTIAL

Single System Bay configuration, All High Density DAEs


NOTE: VMAX 10K File systems include NAS components at the top of System Bay1.

System Bay 1
All High density DAEs
(300 drives)

Empty NOTE: This bay type cannot be used in


Standard and Mixed system configurations.

DAE 10 D1
DAE 9 C1
DAE 8 D1
DAE 7 C1
Vault DAE 6 D0
Vault DAE 5 C0
KVM
Engine 1
Dir 1 & 2
Cable Manager
UPS
Server

SPS
DAE 41 B1
DAE 31 A1
DAE 4 B1
DAE 3 A1
Vault DAE 2 B0
Vault DAE 1 A0
SPS

Config_SingleBay_dense
Rear view

24 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Four System Bays, maximum All Standard DAE configuration, 960 Drives
NOTE: VMAX 10K File systems replace DAEs 9, 10, 11 and 12 in storage bay 1A with NAS components.

Storage Bay 1B System Bay 4 System Bay 3 System Bay 2 System Bay 1 Storage Bay 1A
(180 drives) (150 drives) (150 drives) (150 drives) (150 drives) (180 drives)

DAE 12 D1 DAE 10 D1 DAE 10 D1 DAE 10 D1 DAE 10 D1 DAE 12 D1

DAE 11 C1 DAE 9 C1 DAE 9 C1 DAE 9 C1 DAE 9 C1 DAE 11 C1

DAE 10 B1 DAE 8 D1 DAE 8 D1 DAE 8 D1 DAE 8 D1 DAE 10 B1


From system
bay 4 A1
DAE 9 DAE 7 C1 DAE 7 C1 DAE 7 C1 DAE 7 C1 DAE 9 A1

DAE 8 Vault D0 Vault D0 Vault D0 Vault


B1 D0 DAE 8 B1
DAE 6 DAE 6 DAE 6 DAE 6
Vault Vault Vault Vault
DAE 7 A1 C0 C0 C0 C0 DAE 7 A1
DAE 5 DAE 5 DAE 5 DAE 5
Empty Empty Empty KVM
Empty Engine 4 Engine 3 Engine 2 Engine 1 Empty
Dir 7 & 8 Dir 5 & 6 Dir 3 & 4 Dir 1 & 2
Cable Manager Cable Manager Cable Manager Cable Manager
DAE 6 D1 UPS DAE 6 D1
Empty Empty MIBE Server

DAE 5 SPS SPS SPS SPS


C1 DAE 5 C1
DAE 4 B1 DAE 4 B1 DAE 4 B1 DAE 4 B1
DAE 4 B1 DAE 4 B1
From system From system
bay 3 DAE 3 A1 DAE 3 A1 DAE 3 A1 DAE 3 A1 bay 1
DAE 3 A1 DAE 3 A1
Vault Vault Vault Vault
B0 B0 B0 B0
DAE 2 B1 DAE 2 DAE 2 DAE 2 DAE 2 DAE 2 B1
Vault A0 Vault A0 Vault A0 Vault A0
DAE 1 A1 DAE 1 DAE 1 DAE 1 DAE 1 DAE 1 A1
Empty SPS SPS SPS SPS
Empty

Rear view SBC_Config-16_rear_unif

Customer Service Quick Reference Guide 25


EMC CONFIDENTIAL

Four System Bays, dispersed, maximum All Standard DAE configuration, 960 Drives
NOTE: VMAX 10K File systems replace DAEs 9, 10, 11 and 12 in storage bay 1A with NAS components.

System Bay 4 System Bay 3 Storage Bay 1B System Bay 2 System Bay 1 Storage Bay 1A

DAE 10 DAE 10
Empty DAE 12 DAE 10 DAE 10
Empty D1
D1 D1 D1 D1 DAE 12 D1

DAE 9 C1 Empty
DAE 9 C1 DAE 11 C1 DAE 9 C1 Empty
DAE 9 C1 C1
DAE 11
DAE 10
DAE 8 D1 DAE 8 D1 B1 DAE 8 D1 DAE 8 D1 B1
DAE 10

DAE 7 C1 DAE 7 C1 DAE 9 A1 DAE 7 C1 DAE 7 C1 A1


DAE 9
Vault Vault DAE 8 Vault Vault DAE 8
DAE 6 D0 DAE 6 B1 DAE 6 D0 DAE 6 D0 B1
D0
Vault Vault DAE 7 A1 Vault Vault A1
C0 C0 C0 DAE 7
DAE 5 DAE 5 C0 DAE 5 DAE 5
Empty KVM Empty KVM
Engine 4 Engine 3 Empty Engine 2 Engine 1 Empty
Dir 7 & 8 Dir 5 & 6 Dir 3 & 4 Dir 1 & 2
Cable Manager Cable Manager Cable Manager Cable Manager
DAE 6 D1 UPS DAE 6 D1
Empty Empty MIBE Server

SPS SPS C1 SPS SPS


DAE 5 DAE 5 C1

DAE 4 DAE 4 B1 DAE 4 DAE 4 B1


B1 B1
DAE 4 B1 DAE 4 B1
DAE 3 DAE 3 A1 DAE 3 DAE 3 A1
A1 A1
DAE 3 A1 DAE 3 A1
Vault Vault Vault Vault
DAE 2 B0 DAE 2 B0 DAE 2 B0 DAE 2 B0
DAE 2 B1 DAE 2 B1
Vault Vault Vault Vault
A0 A0 A0 A0
DAE 1 DAE 1 A1 DAE 1 DAE 1
DAE 1 DAE 1 A1
SPS SPS SPS SPS
Empty Empty

Dispersion using optical cables. SBC_Config-16_rear_sep.eps


10-meter maximum distance between system bays 2 and 4.

Rear view

26 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Four System Bays, maximum All High Density DAE configuration, 1200 Drives
NOTE: VMAX 10K File systems include NAS components at the top of System Bay 1.

System Bay 4 System Bay 3 System Bay 2 System Bay 1

Empty Empty Empty Empty

DAE 10 D1 DAE 10 D1 DAE 10 D1 DAE 10 D1


DAE 9 C1 DAE 9 C1 DAE 9 C1 DAE 9 C1
DAE 8 D1 DAE 8 D1 DAE 8 D1 DAE 8 D1
DAE 7 C1 DAE 7 C1 DAE 7 C1 DAE 7 C1
Vault DAE 6 D0 Vault DAE 6 D0 Vault DAE 6 D0 Vault DAE 6 D0
Vault DAE 5 C0 Vault DAE 5 C0 Vault DAE 5 C0 Vault DAE 5 C0
Empty Empty Empty KVM
Engine 4 Engine 3 Engine 2 Engine 1
Dir 7 & 8 Dir 5 & 6 Dir 3 & 4 Dir 1 & 2
Cable Manager Cable Manager Cable Manager Cable Manager
UPS
Empty Empty MIBE Server

SPS SPS SPS SPS


DAE 41 B1 DAE 41 B1 DAE 41 B1 DAE 41 B1
DAE 31 A1 DAE 31 A1 DAE 31 A1 DAE 31 A1
DAE 4 B1 DAE 4 B1 DAE 4 B1 DAE 4 B1
DAE 3 A1 DAE 3 A1 DAE 3 A1 DAE 3 A1
Vault DAE 2 B0 Vault DAE 2 B0 Vault DAE 2 B0 Vault DAE 2 B0
Vault DAE 1 A0 Vault DAE 1 A0 Vault DAE 1 A0 Vault DAE 1 A0
SPS SPS SPS SPS

Customer Service Quick Reference Guide 27


EMC CONFIDENTIAL

Four System Bays, dispersed, maximum All High Density DAE configuration, 1200
Drives
NOTE: VMAX 10K File systems include NAS components at the top of System Bay 1.

System Bay 4 System Bay 3 System Bay 2 System Bay 1

Empty Empty Empty Empty

DAE 10 D1 DAE 10 D1 DAE 10 D1 DAE 10 D1


DAE 9 C1 DAE 9 C1 DAE 9 C1 DAE 9 C1
DAE 8 D1 DAE 8 D1 DAE 8 D1 DAE 8 D1
DAE 7 C1 DAE 7 C1 DAE 7 C1 DAE 7 C1
Vault DAE 6 D0 Vault DAE 6 D0 Vault DAE 6 D0 Vault DAE 6 D0
Vault DAE 5 C0 Vault DAE 5 C0 Vault DAE 5 C0 Vault DAE 5 C0
Empty Empty Empty KVM
Engine 4 Engine 3 Engine 2 Engine 1
Dir 7 & 8 Dir 5 & 6 Dir 3 & 4 Dir 1 & 2
Cable Manager Cable Manager Cable Manager Cable Manager
UPS
Empty Empty MIBE Server

SPS SPS SPS SPS


DAE 41 B1 DAE 41 B1 DAE 41 B1 DAE 41 B1
DAE 31 A1 DAE 31 A1 DAE 31 A1 DAE 31 A1
DAE 4 B1 DAE 4 B1 DAE 4 B1 DAE 4 B1
DAE 3 A1 DAE 3 A1 DAE 3 A1 DAE 3 A1
Vault DAE 2 B0 Vault DAE 2 B0 Vault DAE 2 B0 Vault DAE 2 B0
Vault DAE 1 A0 Vault DAE 1 A0 Vault DAE 1 A0 Vault DAE 1 A0
SPS SPS SPS SPS

Dispersion using optical cables.


10-meter maximum distance between system bays 2 and 4. Config_dense_disp_rear_987.eps

R i

28 Customer Service Quick Reference Guide


Engine Components
EMC CONFIDENTIAL

Engine Power Supply/Cooling Modules — Front View

Enclosure/fault (upper)
Chassis power (lower)
Power/fault

Power supply/cooling module


#6
1
2

Odd director 2
1

Even director

ICO-3973

Part number information for component #6 is available in Table 6 on page 79. Information about engine power supply LED status is in
Table 2 on page 43. Information about enclosure LED status is in Table 1 on page 43.

Customer Service Quick Reference Guide 31


EMC CONFIDENTIAL

Management Modules — Rear View

Even director Odd director

Management Module B Management Module A


#15

Power/Service
Port activity
Service Management
port port
Link state

SPS Service
COM2 port COM1 port

SYM-002579

Part number information for component #15 is available in Table 6 on page 79. Information about LED status is in Table 4 on page 45.
Page 60 through page 66 provides information on Management Module Ethernet and RS-232 sense cabling.

32 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

System Interface Boards (SIB) and Connections — Rear View

Even director Odd director


slot slot
0 0

1
0

0
SYM-002586
1
0

System Interface
Board (SIB)
#16

Port A
(connects to MIBE A)
1

Port B
0

(connects to MIBE B)

Part number information for component #16 is available in Table 6 on page 79. Fabric cabling is provided on page 67.

Customer Service Quick Reference Guide 33


EMC CONFIDENTIAL

Fibre Channel Back End I/O Modules, Slots and Ports — Rear View

Even director Odd director


slot slot slot slot
1 2 1 2

Back End Fibre Channel


I/O Module (without encryption)
#18

Back End Fibre Channel


I/O Module (with encryption)
#32 A0, A1 C0, C1
B0, B1 D0, D1
Slot 1 Slot 2
SYM-002580_987

Part number information for component #18 and #32 is available in Table 6 on page 79.

34 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

4 and 8 Gb/s Fibre Channel Front-End I/O Modules, Slots and Ports — Rear View

Even director Odd director


slot slot slot slot
3 4 3 4

slot 3
3 2 LED and
hardware etch
1
0

E0, E1 G0, G1 Logical ports


F0, F1 H0, H1
slot 3 slot 4
SYM-002581

Customer Service Quick Reference Guide 35


EMC CONFIDENTIAL

16 Gb/s Fibre Channel Front End I/O Module, Slots and Ports — Rear View

Even director Odd director


slot slot slot slot
3 4 3 4

16 Gb/s Fibre Channel

1
LED and
hardware etch
0

E0, F0 G0, H0 Logical ports


slot 3 slot 4
SYM-002581_987

36 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

4 Gb/s Fibre Channel Front-End I/O Modules, Components — AP only

Front End Fibre Channel


I/O Module

#22
4 Gb Fibre

3
Label

2
here
SFP SM module

1
(2/4 Gb Fibre)

3
#24

0
2
1
0
SFP MM module Fibre Channel 4-port I/O Module options
(2/4 Gb Fibre)
MM SM MM MM
#23
MM SM SM SM
MM SM MM MM
MM SM MM SM
4 MM 4 SM 3 MM, 2 MM, ICO-IMG-000893_987

ports ports 1 SM ports 2 SM ports

Part information for components #22, #23, and #24 is available in Table 6 on page 79.

Customer Service Quick Reference Guide 37


EMC CONFIDENTIAL

8 Gb/s Fibre Channel Front-End I/O Module, Components

Front-End Fibre Channel


I/O Module
#19
8 Gb Fibre

3
Label

2
here
SFP SM module
(2/4/8 Gb Fibre)

1
3
#21

0
2
1
0

Fibre Channel 4-port I/O Module options SFP MM module


(2/4/8 Gb Fibre)
MM SM MM MM
#20
MM SM SM SM
MM SM MM MM
MM SM MM SM
4 MM 4 SM 3 MM, 2 MM,
ports ports 1 SM ports 2 SM ports SYM-002588ww

Part number information for components #19, #20 and #21is available on Table 6 on page 79.

38 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

16 Gb/s Fibre Channel Front End I/O Module, Components

Front End Fibre Channel


I/O Module
#37
16 Gb Fibre

1
Label
here
SFP MM module
(8/16 Gb Fibre)

0
#38

1
0

2-port Fibre Channel I/O Module options (8/16 Gb)


MM

MM

2 MM
ports
SYM-002588_16Gb_987

Part number information for components #37and #38 and is available on Table 6 on page 79.

Customer Service Quick Reference Guide 39


EMC CONFIDENTIAL

GbE with iSCSI/FCoE or SRDF Front-End I/O Modules, Slots and Ports — Rear View

Even director Odd director


slot slot slot slot
3 4 3 4

1
LED and
hardware etch
0

E0, F0 G0, H0
Slot 3 Slot 4
SYM-002582

40 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

GbE with iSCSI/FCoE or SRDF Front-End I/O Modules, Components

Front-End GbE with iSCSI/FCoE Label


here
I/O Module (10 Gb/s)

1
#25

1
Front-End GbE with iSCSI
I/O Module (1 Gb/s)

0
#27

0
SFP MM module SFP MM module GbE with iSCSI/FCoE
(10 GbE with iSCSI/FCoE) (1 GbE with IPSec/iSCSI) 2-port I/O MM option
#26 #28
MM
MM

10 GbE iSCSI/FCoE 1 GbE IPSec/iSCSI 2 MM ports


SYM-002587

Part number information for components #25, #26, #27, and #28 is available in Table 6 on page 79.

Customer Service Quick Reference Guide 41


EMC CONFIDENTIAL

Director

Cache memory modules


#12
Cache memory
Director module cover
#17

eFlash module

Power
SP fault

Do not remove

SYM-002589

Part number information about components #12 and #17 are available in Table 6 on page 79. Information about LED status is in Table 3 on
page 44.

42 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

LED Indicators

Table 1 Engine Enclosure LEDs

LED name Color Status

Blue:
Chassis power Blue
Power is on

Amber:
Enclosure fault Amber
Fault on director or Management Module

Table 2 Engine power supply/cooling module LED

LED name Color Status


Green:
Normal
Amber steady-state:
Under voltage if power is on
Overvoltage
Amber/green Internal fan fault
Power/fault
PIC watchdog fault
PS calibration incorrect
Amber flashing:
Disabled due to out-of-range condition
Disabled because SP_INS_N is high
No input voltage present

Customer Service Quick Reference Guide 43


EMC CONFIDENTIAL

Table 3 Director LEDS

LED name Color Status

Green:
Power
Green Onboard DC/DC on and within spec

White on:
Director too hot to remove
Unsafe to remove White
White off:
Safe to remove director
Off:
Board not powered
Amber:
1/4 Hz, BIOS booting
SP Fault Amber/blue
1 Hz, POST booting
4 Hz, OS booting
Blue:
OS booted

44 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table 4 Management Module LEDS

LED name Color Status


Green:
Power is on
Power/service Green/yellow
Yellow:
Module is inserted, fault detected
Amber flicker:
Port activity
Amber 1 Hz flashing:
Port activity Amber
Port marking
Off:
No port activity (not a fault indicator)
Green:
Link connection is active
Green 1 Hz flashing:
Link state Green
Port marking
Off
Link is inactive (not a fault indicator)

Customer Service Quick Reference Guide 45


EMC CONFIDENTIAL

Table 5 UPS LEDs


LED name Color Status
Green:
UPS on and operating from AC power
On Line (front) Green
Off:
UPS off
Off:
Output load within UPS rating
Output Overload (front) Red
Red:
Output exceeds UPS rating
Amber:
UPS operating on battery
On Battery (front) Amber
Off:
UPS not operating on battery
Red:
Battery is detected to be low in capacity and requires replacement(fault)
Replace Battery (front) Red
Off:
Battery is within specification
Green:
Main input AC is present
AC Present, Main Input (rear) Green
Off:
Main input AC is not present or insufficient.
Green:
Auxilliary input AC is present
AC Present, AUX Input (rear) Green
Off:
Auxilliary input AC is not present or insufficient.

46 Customer Service Quick Reference Guide


Front-End Configurations
EMC CONFIDENTIAL

4 Gb/s Fibre Channel Front-End Options — AP only


Two 4 Gb/s Fibre Channel Front-End I/O Modules. Information about 4 Gb/s Fibre Channel hardware parts and components is on
page 37.

8 FC engine
Fibre Fibre
Director (even) Channel Director (odd) Channel
F1

F1

3
3

Module
Module

Module

Module
F1 3

EndorI/OGlactan
EndorI/OGlactan

EndorI/OGlactan

EndorI/OGlactan
FA

Fabric
Fabric

C0,, C1,D0,D1

C1,D0,D1
,D0,,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
F0

F0
A
A

2
2

F0
, ,

2 FA

Aurora
Aurora

BE

BE

BE
BE

C0,, C1,
SIB
SIB

Spartan
Spartan

Spartan

Spartan
E1 1 FA

MM
E1

E1

1
Fabric
Fabric

Back
Back

Back

Back
E0 0 FA

MM
E0

E0

0
0

slot 3 slot 4 (empty)


SL_fibreIO_2_SRDF
Slot 3 Slot 4 Slot 3 Slot 4

4 FC / 2 FC SRDF engine
Fibre Fibre
Director (even) Channel Director (odd) Channel
F1

F1

3
3

Module
Module

Module

Module F1 3 NC
EndorI/OGlactan
EndorI/OGlactan

EndorI/OGlactan

EndorI/OGlactan
Fabric
Fabric

C1,D0,D1
,D0,,D1

C0,, C1,D0,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
F0

F0
A
A

2
2

F0 2 RF
, ,
Aurora
Aurora

BE

BE

BE
BE

C0,, C1,

SIB
SIB

E1 1 FA
Spartan
Spartan

Spartan

Spartan

MM
E1

E1

1
Fabric
Fabric

Back
Back

Back

Back

E0 0 FA
MM
E0

E0

0
0

slot 3 slot 4 (empty)


Slot 3 Slot 4 Slot 3 Slot 4 SL_fibreIO_2_SRDF

KEY:
SymmWin port Protocol
Hardware port FA=Fibre Channel
RF=SRDF/Fibre

Customer Service Quick Reference Guide 49


50
Aurora
SIB Aurora
SIB Aurora
SIB
Fabric Fabric Fabric Fabric Fabric Fabric

A A A

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE

A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module

Director (even)

Director (even)
Director (even)
BE BE BE

C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1 C1,D0,D1
C0,, C1,
,D0,,D1

E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1

Slot 3

Slot 3
Slot 3
Fibre

Fibre
Fibre
0 1 2 3 0 1 2 3 0 1 2 3
Channel

Channel
Channel
G0 G1 H0 H1
G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3

Slot 4

Slot 4
Slot 4
0 1 2 3 0 1 2 3
EMC CONFIDENTIAL

SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric

A A A

Back
Spartan Module
EndorI/OGlactan Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module
BE BE BE

A1,,B0,,B1
A0,, A1,B0,B1 A1,,B0,,B1
A0,, A1,B0,B1 A0,, A1,B0,B1
A1,,B0,,B1

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE
16 FC engine

C1,D0,D1
C0,, C1,
,D0,,D1 C1,D0,D1
C0,, C1,
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1

E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1
MM MM MM MM MM MM
Slot 3

8 FC / 4 FC SRDF engine

Slot 3
Slot 3
Fibre

Fibre
Fibre

0 1 2 3 0 1 2 3 0 1 2 3
12 FC / 2 FC SRDF engine
Director (odd) Channel

Director (odd) Channel


Director (odd) Channel

G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3 0 1 2 3 0 1 2 3
Slot 4

Slot 4
Slot 4
F0
F1

E0
E1

F0
F1
F0
F1

E0
E1
E0
E1
3

0
1
2

3
3

0
1
2
0
1
2
slot 3

Slot 3
Slot 3
FA
FA
FA
FA

FA
FA
FA
FA
FA
FA

RF
NC
H0
H1
H0
H1

G0
G1
G0
G1
H0
H1

G0
G1

3
3

0
1
2
0
1
2
3

0
1
2

Slot 4
Slot 4
slot 4

FA
FA
FA
FA

RF
NC
RF
NC
FA
FA
FA
FA

sl_fibreIO_4

SL_fibreIO_4_SRDF
SL_fibreIO_2_SRDF
8 Gb/s Fibre Channel Front-End Options

KEY:

Hardware port
SymmWin port
Protocol
Four 8 Gb/s Fibre Channel Front-End I/O Modules. Information about 8 Gb/s Fibre Channel hardware components is on page 38.

RF=SRDF/Fibre
FA=Fibre Channel

Customer Service Quick Reference Guide


EMC CONFIDENTIAL

16 Gbs Fibre Channel Front End Options


Four 16 Gb/s Fibre Channel Front End I/O Modules. Information about 16 Gb/s Fibre Channel hardware components is on page 39.

8 FC engine
Fibre Fibre
Director (even) Channel Director (odd) Channel
F1
F0

F1
F0
H0

H0
1

1
1

Module
Module

Module

Module
EndorI/OGlactan
EndorI/OGlactan

EndorI/OGlactan

EndorI/OGlactan
F0 1 FS H0 1 FS

Fabric
Fabric

C1,D0,D1
,D0,,D1

C1,D0,D1
,D0,,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
F0

F0
A
A

Aurora
Aurora

BE

BE

BE
BE

C0,, C1,

C0,, C1,
SIB
SIB

Spartan
Spartan

Spartan

Spartan

MM
E1
E0

E1
E0
G0

G0
0

0
Fabric
Fabric

0
0

E0 0 FS G0 FS

Back
Back

Back

Back

MM
E0

E0
Slot 3 Slot 4
Slot 3 Slot 4 Slot 3 Slot 4 SL_16GbfibreIO_8

KEY:
SymmWin port Protocol
Hardware port FS=16G Fibre Channel

Customer Service Quick Reference Guide 51


EMC CONFIDENTIAL

GbE with iSCSI/FCoE and SRDF Front-End Options — AP only


Two GbE Front-End I/O Modules. FCoE and iSCSI are provided on 10 GbE I/O modules. FCoE is not available on 1 GbE I/O modules.
Information about 10 GbE components is on page 40 and page 41.

4 iSCSI or FCoE engine


Director (even) iSCSl/FCoE Director (odd) iSCSI/FCoE

Module
Module

Module

Module
Glactan
Glactan

Glactan

Glactan
F0 1

Fabric
Fabric

C1 D0 D1
C0, C1,D0,D1

C1,,D0,,D1
C0,, C1,D0,D1
SE/FE
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
F0

F0
A
A

QuickSand

QuickSand
1

EndorI/O
EndorI/O

EndorI/O

EndorI/O

1
Aurora
Aurora

BE

BE

BE
BE

SIB
SIB

Spartan
Spartan

Spartan

Spartan
0

Fabric
Fabric

SE/FE
E0

E0
E0
C0

Back
Back

Back

Back
B
B

0
Slot 3 Slot 4 (empty)
SL_gige_iscsi_fcoe_4
Slot 3 Slot 4 Slot 3 Slot 4

2 iSCSI or FCoE / 2 SRDF engine


Director (even) iSCSl/FCoE Director (odd) iSCSI/FCoE
Module
Module

Module

Module
Glactan
Glactan

Glactan

Glactan
Fabric
Fabric

C1,,D0,,D1
C0,, C1,D0,D1

C1,,D0,,D1
C0,, C1,D0,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1

F0 1 RE
F0

F0
A
A

QuickSand
F0
1

EndorI/O
EndorI/O

EndorI/O

EndorI/O

1
Aurora
Aurora

BE

BE

BE
BE

SIB
SIB

Spartan
Spartan

Spartan

Spartan
Fabric
Fabric

E0

E0
E0 0 SE/FE
Back
Back

Back

Back
B
B

0 Slot 3 Slot 4 (empty)


SL_gige_iscsi_fcoe_2_SRDF
Slot 3 Slot 4 Slot 3 Slot 4

KEY:
SymmWin port Protocol
Hardware port FE=FCoE
SE=iSCSI
RE=SRDF/Ethernet

52 Customer Service Quick Reference Guide


Aurora
SIB SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric
B A B A B A

Back
Spartan
EndorI/O
Glactan
Module Back
Spartan
EndorI/O
Glactan
Module Back
Spartan
EndorI/O
Glactan
Module
BE BE BE

Director (even)
Director (even)

Director (even)
A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/O
Glactan
Module Back
Spartan Glactan
EndorI/O Module Back
Spartan
EndorI/O
Glactan
Module
BE BE BE

C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,D0,D1
, ,
QuickSand QuickSand QuickSand
E0 F0
F0 E0 F0
F0 E0 F0

Slot 3
Slot 3
Slot 3
0 1 0 1 0 1

iSCSl/FCoE
QuickSand
G0 H0
iSCSl/FCoE

G0 H0 G0 H0

iSCSl/FCoE

Slot 4
Slot 4
Slot 4
0 1 0 1 0 1

Customer Service Quick Reference Guide


SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric
B A B A B A

Back
Spartan
EndorI/O Module
Glactan Spartan
Back EndorI/O
Glactan
Module Spartan
Back EndorI/O
Glactan
Module
BE BE BE

Director (odd)
Director (odd)

Director (odd)

A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/O Module
Glactan Back
Spartan Glactan
EndorI/O Module Back
Spartan
EndorI/O
Glactan
Module
BE BE BE
C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,D0,D1
C , 0,,

QuickSand
8 iSCSI or FCoE engine

E0 F0 E0 F0 E0 F0
Slot 3

Slot 3
Slot 3

0 1 0 1 0 1
QuickSand
iSCSI/FCoE
iSCSI/FCoE

iSCSI/FCoE

G0 H0 G0 H0 G0 H0
Slot 4

Slot 4
Slot 4

0 1 0 1 0 1
4 iSCSI or FCoE / 4 SRDF engine
6 iSCSI or FCoE / 2 SRDF engine
Information about iSCSI and FCoE components is on page 40 and page 41.

E0
F0

E0
F0
E0
F0
0
1

0
1
0
1
Slot 3

Slot 3
Slot 3

RE

SE/FE
SE/FE
SE/FE

SE/FE
SE/FE

G0
H0
G0
H0
G0
H0

0
1
0
1
0
1

Slot 4
Slot 4
Slot 4

RE
RE

SE/FE
SE/FE

SL_6gige_2SRDF
SE/FE
SE/FE

SL_gige_iscsi_fcoe_4_SRDF
SL_gige_iscsi_fcoe_4

KEY:
GbE with iSCSI/FCoE and SRDF Front-End Options

Hardware port
SymmWin port
FE=FCoE
SE=iSCSI
Protocol
Four GbE Front-End I/O Modules. FCoE and iSCSI is provided on 10 GbE I/O modules. FCoE is not available on 1 GbE I/O modules.

RE=SRDF/Ethernet

53
EMC CONFIDENTIAL
EMC CONFIDENTIAL

Mixed Fibre Channel and GbE with iSCSI/FCoE and SRDF Front-End Options
Two 8 Gb/s Fibre Channel and 2 GbE Front-End I/O Modules. FCoE and iSCSI is provided on 10 GbE I/O modules. FCoE is not
available on 1 GbE I/O modules. Information about iSCSI and FCoE components is on page 40 and page 41.

8 FC / 4 iSCSI or FCoE engine


Fibre Fibre iSCSI/FCoE
Director (even) Channel iSCSl/FCoE Channel
F1

F1
3

3
Module
Module

Module

Module
3

Glactan
Glactan

Glactan

Glactan
F1 FA

Fabric
Fabric

,D0,,D1
C1,D0,D1

,D0,,D1
C1,D0,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
H0
H0

H0
A
A

1
F0

F0
SE/FE
QuickSand

QuickSand
1
F0
2

2
2

EndorI/O
EndorI/O

EndorI/O

EndorI/O

1
FA

Aurora
Aurora

BE

BE

BE
BE

C0,, C1,

C0,, C1,
SIB
SIB

FA

Spartan
Spartan

Spartan

Spartan
E1 1 FA
E1

E1
G0

G0
Fabric
Fabric

Back
Back

Back

Back

1
G0 0 SE/FE

B
B

0 FA

0
E0 0 FA
E0

E0
0

0
slot 3 Slot 4
SL_fibreIO_2_gige_iscsi_fcoe
Slot 3 Slot 4 Slot 3 Slot 4

8 FC / 2 iSCSI or FCoE/2 SRDF engine


Fibre Fibre iSCSI/FCoE
Director (even) Channel iSCSl/FCoE Channel
F1

F1
3

3
Module
Module

Module

Module
3
Glactan
Glactan

Glactan

Glactan
F1 FA
Fabric
Fabric

C1,,D0,,D1
C0,, C1,D0,D1

C1,,D0,,D1
C0,, C1,D0,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
H0
H0

H0
A
A

1
F0

F0
RE
QuickSand

QuickSand
1

F0
2

2
2
EndorI/O
EndorI/O

EndorI/O

EndorI/O

1
FA
Aurora
Aurora

BE

BE

BE
BE

SIB
SIB

FA
Spartan
Spartan

Spartan

Spartan

E1 1 FA
E1

E1
G0

G0
Fabric
Fabric

Back
Back

Back

Back

1
G0 0 SE/FE
B
B

FA

0
E0 0 FA
E0

E0
0

0
slot 3 Slot 4
SL_8fibre_2gige_2SRDF
Slot 3 Slot 4 Slot 3 Slot 4

4 FC / 2 FC SRDF / 2 iSCSI or FCoE / 2 SRDF engine


Fibre Fibre iSCSI/FCoE
Director (even) Channel iSCSl/FCoE Channel KEY:
Protocol
F1

F1
33

3
F1

SymmWin port
Module
Module

Module

Module

F1 3 NC
Glactan
Glactan

Glactan

Glactan

FA=Fibre Channel
Fabric
Fabric

C0,, C1,D0,D1

C1,,D0,,D1
C0,, C1,D0,D1
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1

H0 1 RE Hardware port
22

2
F0

F0
A
A

F0

H0
H0

F0 RF
, ,

2
1
1

EndorI/O
EndorI/O

EndorI/O

EndorI/O
Aurora
Aurora

BE

BE

BE
BE

FE=FCoE
SIB
SIB

FA
Spartan
Spartan

Spartan

Spartan

E1 1 FA
E1

E1
11

1
E1

G0
Fabric
Fabric

G0

G0 0 SE/FE
Back
Back

Back

Back
B
B

SE=iSCSI
0

E0 0 FA
FA
E0

E0

RF=SRDF/Fibre
E0

00

Slot 3 Slot 4
RE=SRDF/Ethernet
Slot 3 Slot 4 Slot 3 Slot 4 SL_fibreIO_2_SRDF_gige_iscsi_fcoe_2_SRDF

54 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Mixed 16 Gb/s Fibre Channel and GbE with iSCSI/FCoE and SRDF Front End
Options
Two 16 Gb/s Fibre Channel and 2 GbE iSCSI or FCoE Front End I/O Modules. FCoE and iSCSI is provided on 10 GbE I/O
modules. FCoE is not available on 1 GbE I/O modules. Information about iSCSI and FCoE components is on page 40 and page 41. Information
about 16 Gb/s Fibre Channel hardware components is on page 39.

4 FC / 4 iSCSI or FCoE engine


Fibre iSCSl/FCoE Fibre iSCSl/FCoE
Director (even) Channel Director (odd)
Channel
F1
F0

F1
F0

1
1

Module
Module

Module

Module
EndorI/OGlactan
EndorI/OGlactan

EndorI/OGlactan

EndorI/OGlactan
1 FS

Fabric
Fabric

F0
C1,D0,D1
,D0,,D1

C1,D0,D1
,D0,,D1
H0
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1
1 SE/FE
F0

F0

H0
A
A

H0

1
1

Aurora
Aurora

BE

BE

BE
BE

C0,, C1,

C0,, C1,
SIB
SIB

Spartan
Spartan

Spartan

Spartan

MM
E1

E1
E0

E0

G0
G0

Fabric
Fabric

E0 0 FS G0 0 SE/FE

Back
Back

Back

Back

0
0

MM
E0

E0
Slot 3 Slot 4
Slot 3 Slot 4 Slot 3 Slot 4 SL_16GbfibreIO_4FC_4gige

4 FC / 2 iSCSI or FCoE / 2 SRDF engine


Fibre iSCSl/FCoE Fibre iSCSl/FCoE
Director (even) Channel Director (odd)
Channel
F0
F1

F0
F1

1
1

Module
Module

Module

Module
EndorI/OGlactan
EndorI/OGlactan

EndorI/OGlactan

EndorI/OGlactan

1 FS
Fabric
Fabric

F0
C1,D0,D1
,D0,,D1

C1,D0,D1
,D0,,D1
H0
A1,,B0,,B1
A0,, A1,B0,B1

A1,,B0,,B1
A0,, A1,B0,B1

1 RE
F0

F0

H0
A
A

H0

1
1

Aurora
Aurora

BE

BE

BE
BE

C0,, C1,

C0,, C1,
SIB
SIB

Spartan
Spartan

Spartan

Spartan

MM
E1
E0

E1
E0

G0
G0

Fabric
Fabric

E0 0 FS G0 0 SE/FE
Back
Back

Back

Back

0
0

MM
E0

E0

Slot 3 Slot 4
Slot 3 Slot 4 Slot 3 Slot 4 SL_16GbfibreIO_4FC_2gige_2SRDF

KEY:
SymmWin port Protocol
Hardware port FS=16Gb Fibre Channel
RE=SRDF/Ethernet
FE=FCoE
SE=iSCSI

Customer Service Quick Reference Guide 55


56
SIB
Aurora SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric
Fabric Fabric
A A A A

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE BE

A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module

Director (even)
Director (even)

Director (even)
Director (even)
BE BE BE BE

C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1

Slot 3
Slot 3

Slot 3
Slot 3
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

Fibre
Fibre

G0 G1 H0 H1 G0 G1 H0 H1

Fibre
Fibre
G0 G1 H0 H1 G0 G1 H0 H1

Channel
Channel

Channel
Channel
0 1 2 3 3 3 0 1 2 3

Slot 4
Slot 4
0 1 2 0 1 2

Slot 4
Slot 4
EMC CONFIDENTIAL

SIB
Aurora SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric
Fabric Fabric
A A A A

16 DX engine
Back
Spartan
EndorI/OGlactan
Module Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE BE

A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
8 FC / 8 DX engine

Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module

Director (odd)
Director (odd)

Director (odd)
Director (odd)
12 FC / 4 DX engine

BE BE

4 FC / 12 DX engine
BE BE
C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1
MM MM MM MM MM MM MM MM

Slot 3
Slot 3

Slot 3
Slot 3

0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

Fibre
Fibre

Fibre
Fibre

G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1

Channel
Channel

Channel
Channel

0 1 2 3 0 1 2 3

Slot 4
Slot 4

0 1 2 3 0 1 2 3

Slot 4
Slot 4

F0
F1
F0
F1

E0
E1
E0
E1

F0
F1
F0
F1

E0
E1
E0
E1

3
3

0
1
2
0
1
2

3
3

0
1
2
0
1
2

slot 3
slot 3

slot 3
slot 3
FA
FA

DX
DX
DX
DX
DX
DX

DX
DX
DX
DX
DX
DX
DX
DX

H0
H1
H0
H1

G0
G1
G0
G1

H0
H1
H0
H1

G0
G1
G0
G1

3
3

0
1
2
0
1
2

3
3

0
1
2
0
1
2

slot 4
slot 4

slot 4
slot 4
FA
FA
FA
FA

DX
DX
DX
DX
FA
FA
FA
FA
FA
FA

DX
DX

sl_16DX
NOTE: A 16 DX engine configuration is only applicable to systems with multiple engines

sl_8fibre_8DX
sl_12fibre_4DX

sl_4fibre_12DX

KEY:

Hardware port
SymmWin port

DX=FTS
Protocol
8 Gb/s Fibre Channel with Federated Tiered Storage Front-End Options

FA=Fibre Channel

Customer Service Quick Reference Guide


Cabling
EMC CONFIDENTIAL

Engine Power Supply/Cooling Module Power Zones & Engine AC Cabling

front view
Power zone B (black)
Power zone A (gray)

PS A0 PS A1 PS B0 PS B1

DIR A (odd director) DIR B (even director)

rear view

038-003-719 038-003-936

SPS 2B AC Out SPS 2A AC Out


DIR B (even director) DIR A (odd director)
SBC_engine_AC_cabling

Customer Service Quick Reference Guide 59


EMC CONFIDENTIAL

Management Module Ethernet Cabling, One System Bay — Rear View

System Bay 1

Management Management
Module B Module A

Ethernet to
Server customer network
038-004-173

038-003-952

Ethernet to Management Module B


service port in system bay 1
Ethernet to Management Module A
service port in system bay 1
ICO-IMG-000860

Server Components on page 14 provides details about server ports. Management Modules on page 32 shows detailed Management Module
ports.

60 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Management Module Ethernet Cabling, Two System Bays — Rear View

System Bay 2 System Bay 1


Management Management
Module B (all) Module A (all)
038-003-954

Ethernet to
Server customer network
038-003-953 038-004-173
038-003-952

Ethernet to Management Module B


service port in system bay 2

Ethernet to Management Module A


service port in system bay 1
ICO-IMG-000859

Server Components on page 14 provides details about server ports. Management Modules on page 32 shows detailed Management Module
ports.

Customer Service Quick Reference Guide 61


EMC CONFIDENTIAL

Management Module Ethernet Cabling, Three System Bays — Rear View

System Bay 3 System Bay 2 System Bay 1

Management Management
Module B (all) Module A (all)
038-003-954 038-003-954

Ethernet to
Server customer network
038-003-953 038-003-953 038-004-173
038-003-952

Ethernet to Management Module B


service port of system bay 3
Ethernet to Management Module A
service port of system bay 1
ICO-IMG-000858

Server Components on page 14 provides details about server ports. Management Modules on page 32 shows detailed Management Module
ports.

62 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Management Module Ethernet Cabling, Four System Bays — Rear View

System Bay 4 System Bay 3 System Bay 2 System Bay 1

Management Management
Module B (all) Module A (all)
038-003-954 038-003-954 038-003-954

Ethernet to
Server customer network
038-003-953 038-003-953 038-003-953 038-004-173
038-003-952

Ethernet to Management Module B


service port in system bay 4
Ethernet to Management Module A
service port in system bay 1
ICO-IMG-000857

Server Components on page 14 provides details about server ports. Management Modules on page 32 shows detailed Management Module
ports.

Customer Service Quick Reference Guide 63


EMC CONFIDENTIAL

Management Module Ethernet Cabling, Dispersed Bays — Rear View

System Bay 4 System Bay 3 System Bay 2 System Bay 1

Management Management
Module B (all) Module A (all)
038-003-954 P3 (bundled) 038-003-095 (SB2 MM A Service LAN) 038-003-954

Ethernet to
Server customer network
038-003-953 038-003-953 038-004-173
P2 (bundled) 038-003-955 (SB2 MMB Service LAN)

P1 (bundled) 038-003-955 (Server Ethernet)


Ethernet to Management Module B
service port in system bay 4
Ethernet to Management Module A
service port in system bay 1
ICO-IMG-000871

Server Components on page 14 provides details about server ports. Management Modules on page 32 shows detailed Management Modules.

64 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

System Bay 1 RS-232 Sense Cables, SPS & UPS — Rear View

System Bay 1

Management Module B Management Module A

COM2 port COM1 port COM2 port


Management Management Not Connected
to SPS 2B to UPS Test to SPS 2A
Module B Module A

Dir 2 Dir 1
UPS
038-003-894

038-003-085 SPS 2B SPS 2A 038-003-085

!
!

DAE 2 LCC B EXP PRI

038-003-315
!
B EXP PRI
#

PRI EXP
A #

!
PRI EXP

038-003-315

!
!
!
!

To EXP PRI

DAE 1 LCC A
!

B EXP PRI
#

PRI EXP
A #
!

PRI EXP

!
!

To
SPS 1B SPS 1A

rear view SBC-SB1_RS232_SenseCabling

Customer Service Quick Reference Guide 65


EMC CONFIDENTIAL

System Bay 2, 3 & 4 RS-232 Sense Cables, SPS — Rear View

System Bay 2, 3 or 4

Management Module B Management Module A

COM2 port COM2 port Not Connected


Not Management Management
to SPS 2B Connected to SPS 2A
Module B Module A

Even Dir Odd Dir

038-003-085 SPS 2B SPS 2A 038-003-085

!
!

DAE 2 LCC B B
A #
EXP
EXP

PRI
PRI

!
PRI

PRI EXP
EXP
#

038-003-315
038-003-315
!
!
!
!

To EXP PRI

DAE 1 LCC A
!

B EXP PRI
#

PRI EXP
A #
!

PRI EXP
!

To
!

SPS 1B SPS 1A

rear view SBC-SB_RS232_SenseCabling

66 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Fabric (MIBE-SIB) Copper Cabling — Rear View

SIB-A Port SIB-A Port


(connects to MIBE A) (connects to MIBE A)

1
1
SIB-B Port

0
SIB-B Port
0
(connects to MIBE B) (connects to MIBE B)

Dir 8 Dir 7 Dir 6 Dir 5 Dir 4 Dir 3 Dir 2 Dir 1


MIBE B MIBE A

Dir 1 Dir 3 Dir 5 Dir 7 Dir 1 Dir 3 Dir 5 Dir 7


SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A
Dir 2 Dir 4 Dir 6 Dir 8 Dir 2 Dir 4 Dir 6 Dir 8
SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A

MIBE B MIBE A
Port Port Port Port Port Port Port Port
8 10 12 14 8 10 12 14
Port Port Port Port Port Port Port Port
9 11 13 15 9 11 13 15
SBC-FabricCabling

MIBE copper cables to:


SB1 & SB3 - 038-003-950
SB2 - 038-003-704 Port Port Port Port
8 10 12 14
SB4 - 038-003-951
Port Port Port Port
9 11 13 15

Part information for MIBE cables is provided in Table 8 on page 83.

Customer Service Quick Reference Guide 67


EMC CONFIDENTIAL

Fabric Optical Cabling, Dispersed System Layout — Rear View


System Bay 4 System Bay 3 System Bay 2 System Bay 1
(Rear view) (Rear view) (Rear view) (Rear view)

SIB-A Port
SIB-A Port (connects to MIBE A)
(connects to MIBE A)

1
1
SIB-B Port

0
SIB-B Port

0
(connects to MIBE B) (connects to MIBE B)

Dir 2 Dir 1

1
Dir 8 Dir 7 Dir 6 Dir 5 Dir 4 Dir 3
1

1
1

0
0

0
0

0
MIBE B MIBE A

Dir 1 Dir 3 Dir 5 Dir 7 Dir 1 Dir 3 Dir 5 Dir 7


SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A
Dir 2 Dir 4 Dir 6 Dir 8 Dir 2 Dir 4 Dir 6 Dir 8
SIB-B SIB-B SIB-B SIB-B SIB-A SIB-A SIB-A SIB-A

MIBE B MIBE A
Port Port Port Port Port Port Port Port
8 10 12 14 8 10 12 14
Port Port Port Port Port Port Port Port
9
Rear
11
view
13 15 9 11 13 15

From: MIBE B Port 14 From: MIBE B Port 12


To: SB 4 Dir 7 SIB-B To: SB 3 Dir 5 SIB-B Port Port Port Port Port Port Port Port
8 10 12 14 8 10 12 14
From: MIBE B Port 15 From: MIBE B Port 13 Port Port Port Port Port Port Port Port
To: SB 4 Dir 8 SIB-B To: SB 3 Dir 6 SIB-B 9 11 13 15 9 11 13 15

From: MIBE A Port 14 From: MIBE A Port 12


To: SB 4 Dir 7 SIB-A To: SB 3 Dir 5 SIB-A
MIBE A & B Ports 8-11 use copper cables
From: MIBE A Port 15 From: MIBE A Port 13 MIBE A & B Ports 12-15 use optical cable bundles 038-003-915
To: SB 4 Dir 8 SIB-A To: SB 3 Dir 6 SIB-A
SBC-FabricOpticalCabling

68 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Standard DAE Back-End Cabling, Direct

System Bays 1,2,3,4


Even Director Odd Director
Back-End I/O module Back-End I/O module
Slot 1 Slot 1
cables cables
to LCC B to LCC A

!
!
EXP PRI

!
EXP PRI

PRI
#
ON ON

!
PRI EXP

!
I I
!
O O

!
OFF OFF
O

!
D1 EXP PRI

!
#
B

!
EXP PRI

!
PRI EXP
A #
EXP PRI

!
PRI EXP

!
#
EXP PRI

PRI
#

!
PRI EXP

!
!

!
!
!
!
!

EXP PRI
!

!
#
EXP PRI

PRI
#

C1

!
PRI EXP

EXP PRI

!
#

!
EXP PRI

!
I I
PRI EXP
O A # !
O
OFF PRI EXP OFF

!
!
EXP PRI

!
#

!
EXP PRI

PRI
#

!
PRI EXP

!
!
!

!
!
!

EXP PRI

B1

!
#
B EXP PRI

EXP PRI PRI EXP


A
!

#
#
B

D0

!
EXP PRI PRI EXP

PRI EXP
A #
!

PRI EXP

!
!
ON ! ON
I I
!

O O
OFF OFF

Vault

!
!
!
!

EXP PRI

!
#
B

C0
EXP PRI

A1
EXP PRI PRI EXP
A #
!

#
B

!
EXP PRI PRI EXP

PRI EXP
A #
!

PRI EXP

!
!
!
!

!
!

!
!
EXP PRI

!
EXP PRI

PRI
#

!
PRI EXP

EXP PRI

!
#
B

!
EXP PRI

!
PRI EXP
A #

!
PRI EXP

B0

!
!

!
EXP PRI

!
B #

!
EXP PRI

PRI EXP
A #

!
PRI EXP

!
Vault

!
!
!
!
EXP PRI

!
EXP PRI
#
B

!
#
EXP PRI EXP PRI

A0
PRI EXP
# PRI EXP
A

!
PRI EXP #

!
PRI EXP

Even Director Odd Director

!
!
!

Back-End I/O module Back-End I/O module EXP


EXP PRI

PRI

!
PRI EXP
#

cables cables
#
!
PRI EXP

Slot 2 Slot 2
!
to LCC B to LCC A

Rear view SYM-002583

Part information for back-end cables is provided in Table 7 on page 82.

Customer Service Quick Reference Guide 69


EMC CONFIDENTIAL

High Density DAE Back-End Cabling, Direct

System Bays 1,2,3,4 Even Director Odd Director


Back-End I/O module Back-End I/O module
Slot 1 Slot 1

cables cables
to LCC B to LCC A

!
PRI EXP #
EXP PRI

PRI EXP
B #

!
PRI EXP

!
PRI
PRI EXP
EXP
A

!
EXP PRI

EXP PRI
B

!
#
ON B O
ON

D1
PRI EXP
EXP PRI
I I

!
B
PRI EXP

!
O A #
O

!
OFF PRI EXP OFF EXP PRI

!
#
EXP PRI A
EXP PRI PRI EXP
#
A

!
EXP PRI PRI EXP

!
ON ON
O

!
!
I I
B

!
PRI EXP

O O
OFF OFF
O

!
PRI EXP EXP PRI

!
C1
B EXP PRI

!
PRI EXP
#
!

EXP PRI
B PRI EXP
!

!
PRI EXP

!
A
EXP PRI

!
EXP PRI
!

A
EXP PRI #
B EXP PRI

PRI EXP
A #
!

PRI EXP

PRI EXP

ON ON
!
I B I
!

D0 O
OFF

EXP PRI A
O
OFF
!
!

Vault EXP PRI


!

#
B EXP PRI
PRI EXP
PRI
PRI EXP
EXP
B PRI EXP
A #
B

C0 B1
!

PRI EXP
!

A
!

EXP PRI
EXP PRI
A

PRI EXP

EXP PRI
A
A1
EXP PRI PRI EXP

!
#
EXP PRI
B PRI EXP
#

!
PRI EXP
PRI EXP

A
B

!
B0
EXP PRI

!
PRI EXP

B
!
!

EXP PRI
EXP PRI A

!
#
A
EXP PRI
EXP PRI
PRI EXP
#

!
Vault
PRI EXP

Odd Director
PRI EXP

Even Director

!
B

!
PRI EXP

A
B
!

EXP PRI

Back-End I/O module


!

Back-End I/O module EXP PRI PRI EXP

A0
!

#
EXP PRI
B
PRI EXP
#
!

PRI EXP

Slot 2 Slot 2
A
EXP PRI
A
EXP PRI

cables cables
to LCC B to LCC A
Rear view SYM-002583_D25

Part information for back-end cables is provided in Table 7 on page 82.

70 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Standard or Mixed DAE Back-End Cabling, Storage Bay 1A, Standard or


Dispersed System Layout
System Bay 2 System Bay 1 Storage Bay 1A
(D1) (D1) (D1)
SB DAE 10 SB DAE 10 DB DAE 12
from SB DAE 8 from SB DAE 8 from SB(2,4) DAE 10
(C1) (C1) (C1) DAE 7-12
SB DAE 9 SB DAE 9 DB DAE 11
from SB DAE 7 from SB DAE 7 from SB(2,4) DAE 9 from
system bay 2
SB DAE 8 (D1) SB DAE 8 (D1) DB DAE 10 (B1)
from IOM-2 port D1 from IOM-2 port D1 from DB DAE 8

SB DAE 7 (C1) SB DAE 7 (C1) DB DAE 9 (A1)


from IOM-2 port C1 Coast from IOM-2 port C1 from DB DAE 7
to coast
SB DAE 6 (D0) SB DAE 6 (D0) (B1)
bracket DB DAE 8
from IOM-2 port D0 from IOM-2 port D0 from SB(2,4) DAE 4

SB DAE 5 (C0) SB DAE 5 (C0) (A1)


DB DAE 7
from IOM-2 port C0 from IOM-2 port C0 from SB(2,4) DAE 3
Empty KVM Empty
Dir B Dir A Dir B Dir A
(Even) (Odd) (Even) (Odd) (D1)
Empty Empty DB DAE 6
MIBE UPS from SB(1,3) DAE 10
Empty Server DAE 1-6
(C1) from
SPS 2B SPS 2A SPS 2B SPS 2A DB DAE 5
(B1) (B1) from SB(1,3) DAE 9 system bay 1
SB DAE 4 SB DAE 4
from IOM-1 port B1 from IOM-1 port B1 (B1)
DB DAE 4
from DB DAE 2
SB DAE 3 (A1) SB DAE 3 (A1)
from IOM-1 port A1 DB DAE 3 (A1)
from IOM-1 port A1 from DB DAE 1

SB DAE 2 (B0) SB DAE 2 (B0) (B1)


Coast DB DAE 2
from IOM-1 port B0 from IOM-1 port B0
to coast from SB(1,3) DAE 4
(A0) bracket (A0)
SB DAE 1 SB DAE 1 (A1)
from IOM-1 port A0 from IOM-1 port A0 DB DAE 1
from SB(1,3) DAE 3
SPS 1B SPS 1A SPS 1B SPS 1A Empty
Rear view Rear view Rear view

A1 Loop B1 Loop C1 Loop D1 Loop


ICO-IMG-000852

Customer Service Quick Reference Guide 71


EMC CONFIDENTIAL

Standard or Mixed DAE Back-End Cabling, Storage Bay 1B, Standard System
Layout
Storage Bay 1B System Bay 4 System Bay 3

(D1) (D1) (D1)


DB DAE 12 SB DAE 10 SB DAE 10
from SB(2,4) DAE 10 from SB DAE 8 from SB DAE 8

(C1) (C1) (C1)


DAE 7-12 DB DAE 11 SB DAE 9 SB DAE 9
from from SB(2,4) DAE 9 from SB DAE 7 from SB DAE 7
system bay 4 (D1) (D1)
DB DAE 10 (B1) SB DAE 8 SB DAE 8
from DB DAE 8 from IOM-2 port D1 from IOM-2 port D1

Coast
DB DAE 9 (A1) SB DAE 7 (C1) SB DAE 7 (C1)
to coast
from DB DAE 7 bracket from IOM-2 port C1 Coast from IOM-2 port C1
(B1) (D0) to coast (D0)
DB DAE 8 SB DAE 6 bracket SB DAE 6
from SB(2,4) DAE 4 from IOM-2 port D0 from IOM-2 port D0
(A1) SB DAE 5 (C0) SB DAE 5 (C0)
DB DAE 7
from SB(2,4) DAE 3 from IOM-2 port C0 from IOM-2 port C0

Empty Empty Empty


Dir B Dir A Dir B Dir A
DAE 1-6 (D1) (Even) (Odd) (Even) (Odd)
DB DAE 6 Empty Empty
from from SB(1,3) DAE 10 Empty Empty
system bay 3 Empty Empty
(C1)
DB DAE 5 SPS 2B SPS 2A SPS 2B SPS 2A
from SB(1,3) DAE 9 (B1) (B1)
SB DAE 4 SB DAE 4
(B1) from IOM-1 port B1 from IOM-1 port B1
DB DAE 4
from DB DAE 2
SB DAE 3 (A1) SB DAE 3 (A1)
DB DAE 3 (A1) from IOM-1 port A1
from DB DAE 1 from IOM-1 port A1
Coast
to coast
(B1) bracket SB DAE 2 (B0) SB DAE 2 (B0)
DB DAE 2 Coast
from IOM-1 port B0 from IOM-1 port B0
from SB(1,3) DAE 4 to coast
(A0) bracket (A0)
(A1) SB DAE 1 SB DAE 1
DB DAE 1 from IOM-1 port A0 from IOM-1 port A0
from SB(1,3) DAE 3
Empty SPS 1B SPS 1A SPS 1B SPS 1A

Rear view Rear view Rear view

A1 Loop B1 Loop C1 Loop D1 Loop


ICO-IMG-000856

72 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

High Density Back-End Cabling, Standard or Dispersed System Layout


NOTE: High density systems do not have storage bays.
System Bay 3 & 4 System Bay 2 System Bay 1

Empty Empty Empty

SB DAE 10 (D1) SB DAE 10 (D1) SB DAE 10 (D1)


From SB DAE 8 From SB DAE 8 From SB DAE 8
SB DAE 9 (C1) SB DAE 9 (C1) SB DAE 9 (C1)
From SB DAE 7 From SB DAE 7 From SB DAE 7
SB DAE 8 (D1) SB DAE 8 (D1) SB DAE 8 (D1)
From IOM-2 Port D1 From IOM-2 Port D1 From IOM-2 Port D1
SB DAE 7 (C1) SB DAE 7 (C1) SB DAE 7 (C1)
From IOM-2 Port C1 From IOM-2 Port C1 From IOM-2 Port C1
SB DAE 6 (D0) SB DAE 6 (D0) SB DAE 6 (D0)
From IOM-2 Port D0 From IOM-2 Port D0 From IOM-2 Port D0
SB DAE 5 (C0) SB DAE 5 (C0) SB DAE 5 (C0)
From IOM-2 Port C0 From IOM-2 Port C0 From IOM-2 Port C0
Empty Empty KVM
Dir B Dir A Dir B Dir A Dir B Dir A
( Even ) (Odd) ( Even ) (Odd) ( Even ) (Odd)
Empty Cable Manager Cable Manager
Empty MIBE UPS
Empty Empty Server
SPS 2B SPS 2A SPS 2B SPS 2A SPS 2B SPS 2A
SB DAE 41 (B1) SB DAE 41 (B1) SB DAE 41 (B1)
From SB DAE 4 From SB DAE 4 From SB DAE 4
SB DAE 31 (A1) SB DAE 31 (A1) SB DAE 31 (A1)
From SB DAE 3 From SB DAE 3 From SB DAE 3
SB DAE 4 (B1) SB DAE 4 (B1) SB DAE 4 (B1)
From IOM-1 Port B1 From IOM-1 Port B1 From IOM-1 Port B1
SB DAE 3 (A1) SB DAE 3 (A1) SB DAE 3 (A1)
From IOM-1 Port A1 From IOM-1 Port A1 From IOM-1 Port A1
SB DAE 2 (B0) SB DAE 2 (B0) SB DAE 2 (B0)
From IOM-1 Port B0 From IOM-1 Port B0 From IOM-1 Port B0
(A0) (A0) (A0)
SB DAE 1 SB DAE 1 SB DAE 1
From IOM-1 Port A0 From IOM-1 Port A0 From IOM-1 Port A0
SPS 1B SPS 1A SPS 1B SPS 1A SPS 1B SPS 1A

Rear view Rear view Rear view

A1 Loop B1 Loop C1 Loop D1 Loop ICO-IMG-BE_Dense_987

Customer Service Quick Reference Guide 73


74
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3

Data Mover 5

Data Mover 5
EMC CONFIDENTIAL

Data Mover 3

Data Mover 3
0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
Data movers 2, 3, 4, 5

Data movers 2, 3, 4, 5
Data Mover 2

Data Mover 2
Data Mover 4

Data Mover 4

SIB
Aurora
Aurora
SIB SIB
Aurora Fabric Fabric
Fabric Fabric Fabric Fabric
A
A A

Back
Spartan
EndorI/OGlactan
Module
Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE
Director 2

BE BE
Director 2

Director 4

A0,, A1,B0,B1
A1,,B0,,B1
A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module
Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE
BE BE
C0,, C1,
C1,D0,D1
,D0,,D1
C1,,D0,,D1
C0,, C1,D0,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1
E0 E1 F0 F1 E0 E1 F0 F1

0 1 2 3
Slot 3

0 1 2 3 0 1 2 3
Slot 3

Slot 3

G0 G1 H0 H1
G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3
0 1 2 3 0 1 2 3
Engine 1

Engine 1

Engine 2

SIB
Aurora
SIB
Aurora SIB
Aurora Fabric Fabric
Fabric Fabric Fabric Fabric
A
A A

Back
Spartan Module
EndorI/OGlactan
Back
Spartan
EndorI/OGlactan
Module Back
Spartan Module
EndorI/OGlactan
VMAX 10K File, Fibre Channel Cabling, 1 and 2 Engines

BE
BE BE
A0,, A1,B0,B1
A1,,B0,,B1
A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module
Back
Spartan
EndorI/OGlactan
Module
Director 1

Back
Spartan
EndorI/OGlactan
Module
BE
Director 1

Director 3

BE BE
C0,, C1,
C1,D0,D1
,D0,,D1
C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,D0,D1
C1,,D0,,D1
E0 E1 F0 F1
E0 E1 F0 F1 E0 E1 F0 F1

0 1 2 3
Slot 3

0 1 2 3 0 1 2 3
Slot 3

Slot 3

G0 G1 H0 H1
G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3
vnx_cables_1_eng

0 1 2 3 0 1 2 3
vnx_cables_2_eng

Customer Service Quick Reference Guide


0 1 2 3 0 1 2 3

Data Mover 5

Data Mover 3

Customer Service Quick Reference Guide


0 1 2 3 0 1 2 3
Data movers 2, 3, 4, 5

Data Mover 2
Data Mover 4

SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric
A A A

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE
Director 2

Director 6
Director 4

A1,,B0,,B1
A0,, A1,B0,B1 A1,,B0,,B1
A0,, A1,B0,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE

C1,D0,D1
C0,, C1,
,D0,,D1 C1,D0,D1
C0,, C1,
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1

0 1 2 3 0 2 3 0 1 2 3
Slot 3

1
Slot 3
Slot 3

G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3 0 1 2 3 0 1 2 3
Engine 1

Engine 3
Engine 2

SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric
VMAX 10K File, Fibre Channel Cabling, 3 Engines

A A A

Back
Spartan
EndorI/OGlactan
Module Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module
BE BE BE

A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
Director 1

Director 5
Director 3

BE BE BE

C1,D0,D1
,D0,,D1
C0,, C1, C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1

0 1 2 3 0 1 2 3
Slot 3

3
Slot 3

0 1 2
Slot 3

G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3 0 1 2 3 0 1 2 3
vnx_cables_3_eng

75
EMC CONFIDENTIAL
76
0 1 2 3 0 1 2 3

Data Mover 5
EMC CONFIDENTIAL

Data Mover 3

0 1 2 3 0 1 2 3
Data movers 2, 3, 4, 5

Data Mover 2
Data Mover 4

SIB
Aurora SIB
Aurora SIB
Aurora SIB
Aurora
Fabric Fabric Fabric Fabric Fabric Fabric Fabric Fabric
A A A A

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE BE
Director 8
Director 2

Director 4

Director 6

A1,,B0,,B1
A0,, A1,B0,B1 A1,,B0,,B1
A0,, A1,B0,B1 A1,,B0,,B1
A0,, A1,B0,B1 A0,, A1,B0,B1
A1,,B0,,B1
Back
Spartan
EndorI/OGlactan
Module Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
BE BE BE BE
C1,D0,D1
C0,, C1,
,D0,,D1 C1,,D0,,D1
C0,, C1,D0,D1 C1,,D0,,D1
C0,, C1,D0,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1

0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
Slot 3
Slot 3

Slot 3

Slot 3

G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
Engine 4
Engine 1

Engine 2

Engine 3

Aurora
SIB SIB
Aurora SIB
Aurora Aurora
SIB
Fabric Fabric Fabric Fabric Fabric Fabric Fabric Fabric
VMAX 10K File, Fibre Channel Cabling, 4 Engines

A A A A

Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module Spartan
Back EndorI/OGlactan
Module
BE BE BE BE
A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A0,, A1,B0,B1
A1,,B0,,B1 A1,,B0,,B1
A0,, A1,B0,B1
Back
Spartan
EndorI/OGlactan
Module Back
Spartan Module
EndorI/OGlactan Back
Spartan
EndorI/OGlactan
Module Back
Spartan
EndorI/OGlactan
Module
Director 7
Director 1

Director 3

Director 5

BE BE BE BE
C0,, C1,
C1,D0,D1
,D0,,D1 C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,D0,D1
C1,,D0,,D1 C0,, C1,
C1,D0,D1
,D0,,D1
E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1 E0 E1 F0 F1

0 1 2 3 3 0 1 2 3 0 1 2 3
Slot 3

0 1 2
Slot 3

Slot 3

Slot 3

G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1 G0 G1 H0 H1

0 1 2 3 0 1 2 3 0 1 2 3 0 1 2 3
vnx_cables_4_eng

Customer Service Quick Reference Guide


Part Numbers
EMC CONFIDENTIAL

Main Components
Table 6 Main components (Sheet 1 of 3)

Part
Part Name Number Notes
#1 Power distribution unit 100-885-137 Single-phase PDU
Power distribution panel (10K, 10K file) 100-885-138 Single-phase PDP
#2 100-885-139 Three-phase Delta
100-885-140 Three-phase WYE
Standard DAE chassis (energy efficient) 100-886-019 Empty 15-drive DAE chassis with midplane
#3 DAE chassis with midplane 100-886-935 AP only
#4 Standard DAE link control card 303-127-000A For 3.5 inch drives
Standard DAE power supply/cooling module 071-000-518 For 3.5 inch drives
#5 (improved efficiency features) Substitute 071-000-535
Standard DAE power supply/cooling module 017-000-532 AP only
#6 Engine power supply/cooling module 071-000-543 Substitute 071-000-548
#7 Standby power supply 078-000-050 Substitute 078-000-086
#8 Uninterrupted Power Supply (UPS) 078-000-052
#9 Server 090-000-218
#10 Keyboard Video Mouse (KVM) 019-000-090
#11 Modem (optional) 100-602-108

#12 2 GB cache memory module 100-562-863 12 GB director (24 GB engine) - AP only


8 GB cache memory module 100-562-479 48 GB director (96 GB engine)
16 GB cache memory module 100-562-424 72 GB director (128 GB engine)

Customer Service Quick Reference Guide 79


EMC CONFIDENTIAL

Table 6 Main components (Sheet 2 of 3)

Part
Part Name Number Notes
#13 MIBE assembly 100-886-914 MIBE without power supply/cooling module
#14 MIBE power supply/cooling module 071-000-521
#15 Management Module 303-129-101B
#16 System Interface Board 303-184-100A

#17 Director 303-113-700B Director


100-563-451 eFlash - ordered and replaced whenthe Director is replaced
#18 Fibre Channel Back End I/O Module 303-086-101B without encryption
#19 8 Gb/s Fibre Channel Front-End I/O Module 303-092-102B
Small form-factor pluggable transceiver (MM) 019-078-042
#20 (8 Gb/s)
Small form-factor pluggable transceiver (SM) 019-078-043
#21 (8 Gb/s)
#22 4 Gb/s Fibre Channel Front-End I/O Module 303-019-101A AP only

#23 Small form-factor pluggable transceiver (SM) 019-078-032 AP only


(4 Gb/s)

#24 Small form-factor pluggable transceiver (MM) 019-078-039 AP only


(4 Gb/s)

#25 GbE with iSCSI or FCoE Front-End I/O 303-142-100A


Module (10 Gb/s)
#26 Small form-factor pluggable transceiver 019-078-041 For 10 Gb/s modules with FCoE or iSCSI
#27 GbE with iSCSI Front-End I/O Module 303-950-100C

80 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table 6 Main components (Sheet 3 of 3)

Part
Part Name Number Notes
#28 Small form-factor pluggable transceiver 019-078-032 For 1 Gb/s modules with iSCSI, or IPSec
#29 High density DAE 100-886-209 Empty 25-drive DAE chassis with midplane
High density DAE power supply/cooling 071-000-541 For 2.5 inch drives
#30
module
#31 High density DAE link control card (LCC) 303-230-000B For 2.5 inch drives
4 Gb/s Fibre Channel Back End I/O Module 303-176-100B
#32 with encryption
#33 Data Mover enclosure 100-563-109 Empty
#34 Data Mover 110-113-724B-01
#35 Control Station 100-520-152-01
#36 Four-port FC I/O module 303-092-100B
#37 16 Gb/s Fibre Channel Front End I/O Module 303-235-101
Small form-factor pluggable transceiver (MM) 019-078-045 For 16 Gb/s Fibre Channel Front End I/O Module
#38
(16 Gb/s)
Light panel assembly 100-886-118

The most recent part information is available on https://alliance.emc.com/pages/PcdSearch.aspx in the Parts Compatibility Database.

Customer Service Quick Reference Guide 81


EMC CONFIDENTIAL

Back-End Cables
Table 7 Symmetrix Back-end cables

Cable Description Part number


2 meter (78.74 inch) copper Fibre Channel cable Engine to DAE — direct connect 038-003-708

1 meter (39.37 inch) copper Fibre Channel cable Daisy-chain cable (short) 038-003-508

4 meter (157.48 inch) copper Fibre Channel cable Daisy-chain cable (long) 038-003-510

The most recent part information is available on https://alliance.emc.com/pages/PcdSearch.aspx in the Parts Compatibility Database.

82 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

MIBE Cables
Table 8 MIBE QSFP copper & optical cables

Cable Description Part number


1 meter (39.37 inch) copper cable Dir 3, 4/SIB A, B to system bay 2, MIBE A, B/Ports 10,11 038-003-704

2.5 meter (98.43 inch) copper cable Dir 5, 6/SIB A, B to system bay 2, MIBE A, B/Ports 12,13 038-003-950

Dir 1, 2/SIB A, B to system bay 2, MIBE A, B/Ports 8, 9


4.5 meter (177.16 inch) copper cable 038-003-951
Dir 7, 8/SIB A, B to system bay 2, MIBE A, B/Ports 14,15

Optical bundle For dispersed systems, Dir 5,6,7,8 to MIBEs A & B 038-003-915

Table 9 MIBE to MIBE RS-232 cable


Cable Description Part number
MIBE to MIBE RS-232 cable MIBE A to MIBE B 038-003-594

The most recent part information is available on https://alliance.emc.com/pages/PcdSearch.aspx in the Parts Compatibility Database.

Customer Service Quick Reference Guide 83


EMC CONFIDENTIAL

Ethernet Cables

Table 10 Symmetrix Ethernet cables

Cable Zone Description Part number


Ethernet cable, 94 cm (37 inch) Green Server to Management Module A 038-003-677

Ethernet coupling cable, dongle Server to Management Module A 038-004-173

Ethernet coupling cable, dongle Server to customer network 038-004-173

Ethernet cable, 396.2 cm (156 inch) Purple Server to Management Module B 038-003-952

Ethernet cable, 249 cm (98 inch) Purple Engine to engine, even director 038-003-953

Ethernet cable, 274 cm (108 inch) Green Engine to engine, odd director 038-003-954

The most recent part information is available on https://alliance.emc.com/pages/PcdSearch.aspx in the Parts Compatibility Database.

84 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Power Cables
Table 11 Symmetrix system bay, DAE, and SPS power cables (Sheet 1 of 2)

Cable Zone Description Part number


PDU to DAE 7, 8, 9, 10 and SPS 2A to
Power cable, 1 meter (39.37 inch) Gray PDU 038-004-010

PDU to DAE 2, 7, 8, 9, 10 and SPS 2B to


Power cable, 1 meter (39.37 inch) Black 038-004-004
PDU

PDU to DAE 3, 4; PDU to 31, 41 (dense)


Power cable, 167.64 cm (66 inch) Black 038-004-030
SPS 1B to DAE 5, 6

PDU to DAE 3, 4; PDU to DAE 31, 41


Power cable, 167.64 cm (66 inch) Gray (dense) 038-004-031
SPS 1A to DAE 5, 6

Power cable, 200 cm (79 inch) Black PDU to SPS 1B 038-003-992

Power cable, 200 cm (79 inch) Gray PDU to SPS 1A 038-004-008

Power cable, 60.96 cm (24 inch) Black SPS 2B to engine power supply B 038-003-719

Power cable, 60.96 cm (24 inch) Black SPS 1B to DAE 1, 2 038-004-002

Power cable, 60.96 cm (24 inch) Gray SPS 1A to DAE 1, Server to UPS 038-004-022

Power cable, 60.96 cm (24 inch) Gray SPS 2A to engine power supply A 038-003-936

Customer Service Quick Reference Guide 85


EMC CONFIDENTIAL

Table 11 Symmetrix system bay, DAE, and SPS power cables (Sheet 2 of 2)

Cable Zone Description Part number


Power cable, 60.96 cm (24 inch) Black Server to UPS 038-004-002

Power cable, 1 meter (39.37 inch) Black PDU to UPS 038-004-004

Power cable, 1 meter (39.37 inch) Gray PDU to UPS 038-004-010

Table 12 SPS & UPS sense cables

Cable Zone Description Part number


RS-232 cable, 81,28 cm (32 inch) SPS 2A/2B to Management Module 038-003-085

RS-232 cable, 91.44 cm (36 inch) SPS 1A to DAE1, SPS 1B to DAE 2 038-003-315

RS-232, 101.6 cm (40 inch) UPS to Management Module B 038-003-894

Table 13 Storage bay DAE power cables (Sheet 1 of 2)

Cable Zone Description Part number


Power cable, 167.64 cm (66 inch) Black PDU to DAE 1, 2, 3, 4, 7, 8 038-004-030

Power cable, 167.64 cm (66 inch) Gray PDU to DAE 1, 2, 3, 4, 7, 8 038-004-031

Power cable, 1 meter (39.37 inch) Black PDU to DAE 5, 6 038-004-004

86 Customer Service Quick Reference Guide


EMC CONFIDENTIAL

Table 13 Storage bay DAE power cables (Sheet 2 of 2)

Cable Zone Description Part number


Power cable, 1 meter (39.37 inch) Gray PDU to DAE 5, 6 038-004-010

Y power cable Black PDU to DAE 9,10,11,12 038-004-254

Y power cable Gray PDU to DAE 9,10,11,12 038-004-255

Table 14 MIBE power cables

Cable Zone Description Part number


System bay 2 SPS 2A/2B to MIBE AC
Power cable Black 038-003-624
power

Power cable Gray System bay 2 SPS 2A/2B to MIBE AC 038-003-625


power

Customer Service Quick Reference Guide 87


EMC CONFIDENTIAL

Table 15 VMAX 10K File components, cables

Cable Zone Description Part number


Power cable, 2 meter ( 78.74 inch) Black Data Mover to power, zone B 038-018-001

Power cable, 2 meter (78.74 inch ) Gray Data Mover to power, zone A 038-018-002

Fibre Channel back-end optical cable Fibre channel I/O module on Data Mover 038-003-739
5 meter (196.86 inch ) to engine

Null modem DB-9 (debug) cable Control Station to customer service laptop 038-003-458

Ethernet coupling cable, dongle 038-003-718

Ethernet cable, 7.62 meter (25 feet) Control Station to customer network 038-003-467

The most recent part information is available on https://alliance.emc.com/pages/PcdSearch.aspx in the Parts Compatibility Database.

88 Customer Service Quick Reference Guide