Concerte Pipeline Inspection Report NCCL

The inspection report for the concrete pipeline at NCCL Limited indicates that all tested pipes met the required thickness criteria, with measurements ranging from 4.1mm to 4.5mm. The inspection was conducted on January 3, 2025, and the next due date for inspection is July 2, 2025. The report includes a disclaimer stating that it does not guarantee performance or ensure against equipment failure, emphasizing the importance of regular checks and maintenance.

Uploaded by

KARTHIK REDDY
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views

Concerte Pipeline Inspection Report NCCL

The inspection report for the concrete pipeline at NCCL Limited indicates that all tested pipes met the required thickness criteria, with measurements ranging from 4.1mm to 4.5mm. The inspection was conducted on January 3, 2025, and the next due date for inspection is July 2, 2025. The report includes a disclaimer stating that it does not guarantee performance or ensure against equipment failure, emphasizing the importance of regular checks and maintenance.

Uploaded by

KARTHIK REDDY
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Inspection Report of Concrete Pipeline

Report No: 250103-001/NCCL


1. Name of Occupier: NCCL LIMITED

2. Site address: ADANI CONNEX PNQ 27, PIMPRI CHINCHWAD, PUNE, MAHARASHTRA.

3. Nature of process in which Equipment is used: Construction Site

4. Particulars of Equipment:
 Outside Diameter of Pipe-125mm
 Inside Diameter of Pipe-120.5mm
 Original Thickness of Pipe-4.5mm.
 Rejection Criteria- 10% Original Thickness

Sr. No. Pipe Sr. No. Thickness Observed in Remarks


mm
Minimum Maximum
1 Pipe-01 4.1 4.3 Okay
2 Pipe-02 4.1 4.5 Okay
3 Pipe-03 4.3 4.3 Okay
4 Pipe-04 4.2 4.3 Okay
5 Pipe-05 4.3 4.5 Okay
6 Pipe-06 4.4 4.3 Okay
7 Pipe-07 4.3 4.3 Okay
8 Pipe-08 4.1 4.4 Okay
9 Pipe-09 4.4 4.5 Okay
10 Pipe-10 4.2 4.3 Okay
11 Pipe-11 4.3 4.3 Okay
12 Pipe-12 4.3 4.3 Okay

I thoroughly examined this Concrete Pipeline on 03.01.2025 including its fittings and that
the above is a true report of my examination.

Next Due Date of Inspection: 02.07.2025.


Disclaimer : This certificate Neither gives any performance Guarantee nor ensure against any failure of
Equipment’s, it indicates only the present Status of the Equipment’s on the day of Inspection based on the test
carried out, Daily check the above mentioned Equipment’s and all its safety devices for its proper functioning and
safe operation & Favourable weather condition before its use, Maintenance & Safety of above Equipment is in
occupier’s scope follow manufacturer’s instruction for the safe operation & Maintenance.

09

Mr Prashant R Shinde (Competent Person)


Maharashtra: L-1 Shivalaya, Deenanth (M.Sc. Environment Science, ADIS, B. Tech - Mechanical Engineering).
For M/s AUTOMECH ENGINEERING
Mangeshkar Hospital Road, Erandwane, Pune,
Competent Person Factories Act, 1948 Rules, Sec 28, 29 & 31.
Maharashtra – 411004.
Authorized by Director of Factories and Boilers
Karnataka: Rajnagar South, No.45, SBI For Inspection, testing & Certification of Lifting Machine, Cranes, Hoist, Lifts
Appartment, Hubli, Karnataka – 580032. & Lifting tackles, Chains & Rope; Pressure vessels & Pressure Plants.
Email: [email protected] Government of Maharashtra
Phone no: +91 9423732672 / 9657787857 Licence No: MS/DISH/CPC/S-078/22.

Government of Karnataka.

You might also like