Automation_temp
Automation_temp
4. OPC: OPC stands for OLE for Process Control, which is a standard for
exchanging data between different industrial automation applications. It
provides a common interface for connecting different devices and applications,
regardless of the manufacturer or technology used.
5. HMI: HMI stands for Human Machine Interface, which is a device or software
that allows operators to interact with the industrial automation system. HMIs
provide a graphical user interface that displays information about the system's
status and enables operators to control and monitor the system.
Overall, industrial automation communication and interfacing technologies play
a crucial role in ensuring the efficient and reliable operation of industrial
systems. These technologies enable different components of the system to work
together seamlessly, providing real-time data exchange and control capabilities
that are essential for achieving optimal system performance.
1. Fieldbus: This is a type of industrial network that connects field devices such
as sensors and actuators to controllers and other devices in the plant. Examples
of fieldbus protocols include Modbus, DeviceNet, and PROFIBUS.
Industrial Ethernet
Industrial Ethernet is a type of Ethernet networking that is specifically designed
for use in industrial environments such as manufacturing plants, process control
systems, and automation systems. It uses standard Ethernet technology to
provide high- speed data communication and control capabilities, while also
offering the robustness, reliability, and noise immunity required in industrial
applications.
Concept of Fieldbus
A fieldbus is a type of digital communication network used in industrial
automation applications to connect field devices such as sensors and actuators
to controllers and other devices in the plant. Fieldbus technology enables
communication between devices in real-time, allowing for improved control and
monitoring of industrial processes.
Fieldbus systems use a specialized communication protocol that is optimized for
industrial automation applications. Some common fieldbus protocols include
Modbus, PROFIBUS, and Foundation Fieldbus. These protocols allow for data
exchange between devices, and enable real_time control and monitoring of
industrial processes.
MODBUS protocol
MODBUS is a widely used communication protocol in industrial automation
applications for transmitting data between electronic devices. It was developed
in the late 1970s by Modicon, now Schneider Electric, and has since become a
de facto standard in the industry.
MODBUS is a serial communication protocol that allows for communication
between devices over a wired network. It uses a master- slave architecture,
where a master device initiates communication and slave devices respond to
requests. MODBUS protocol specifies the format of the messages that are sent
between the master and the slave devices
There are two types of MODBUS communication: MODBUS ASCII and MODBUS
RTU.
HART protocol is commonly used to communicate with smart field devices such
as sensors and actuators, providing two-way communication between the
device and the control system. This allows for real-time monitoring and control
of industrial processes.
PLCs are designed to work with a variety of hardware devices, including sensors,
actuators, and human-machine interfaces (HMIs). PLCs are designed to be
modular and flexible, allowing for easy interfacing with other hardware devices.
Here are some common methods of interfacing a PLC with other hardware
devices:
1. Input/output (I/O) modules: PLCs are designed to work with a wide range of
I/O modules, which are used to connect sensors and actuators to the PLC. I/O
modules are available in a variety of configurations and can be easily added or
removed as needed.
4. Variable frequency drives (VFDs): VFDs are used to control the speed of
motors in industrial processes. PLCs can be used to interface with VFDs,
allowing for control of motor speed based on the requirements of the process.
5. Safety devices: PLCs can be used to interface with safety devices such as
emergency stop buttons and safety interlocks. This allows the PLC to monitor
the status of these devices and take appropriate action in the event of an
emergency.
The first step in PLC programming is to define the input and output signals.
Inputs are signals fromsensors or switches that detect changes in the
environment, while outputs are signals that controlactuators or devices that
perform actions based on the input signals.
Next, the programmer creates the logic for the program. This involves defining
the conditionsunder which the PLC should perform certain actions. For example,
if a certain sensor detects a change in temperature, the PLC might be
programmed to turn on a fan to cool the environment.
The I/O addressing scheme in ladder logic typically uses a combination of letters
and numbers to specify the address of an I/O device. The letters are used to
indicate the type of device, such as "I" for input or "O" for output. The numbers
are used to indicate the specific address or location of the device in the memory
map of the PLC.
For example, if an input device is connected to the first input channel of the PLC,
its address might be specified as "I0.0" in ladder logic. The first "I" indicates that
it is an input device, while the "0" indicates the input module that the device is
connected to. The ".0" indicates the specific input channel that the device is
connected to on the module.
By using I/O addressing in ladder logic, programmers can easily identify and
manipulate the input and output devices connected to the PLC, allowing them
to create complex control systems for industrial automation.
- OR: combines two or more inputs, and produces an output when at least one
input is true.
- XOR: combines two inputs, and produces an output when one input is true and
the other is false.
Relay-type instructions are named after traditional relay circuits and are used to
control the state of output devices based on the state of input devices.
Relay-type instructions are based on the concept of energizing or de-energizing
a virtual relay coil to control an output device.
- Output Energize (OTE): turns an output device on when the input condition is
true.
- Output Latch (OTL): latches the output device on even if the input condition is
no longer true.
- Output Unlatch (OUT): turns off an output device when the input condition is
false.
1. Input Scan: The PLC reads the state of the input devices connected to it. This
involves checking the status of sensors, switches, and other input devices to
determine whether they are on or off.
2. Program Execution: The PLC executes the ladder logic program, one rung at a
time, starting with the first rung. The program consists of a series of instructions
that manipulate the state of the input and output devices based on the logic
specified in the program.
3. Output Update: After executing the program, the PLC updates the state of the
output devices connected to it. This involves setting the output devices to either
on or off based on the logic specified in the program.
4. Delay: The PLC may pause for a short time before starting the next scan cycle.
This delay allows the output devices to settle into their new states before the
next cycle begins.
The program scan cycle is a continuous process that runs repeatedly as long as
the PLC is powered on. During each cycle, the PLC checks the state of the input
devices, executes the program logic, updates the output devices, and then waits
for a short delay before starting the next cycle.
The length of the scan cycle depends on the complexity of the program and the
processing speed of the PLC. In some cases, it may take only a few milliseconds
to complete a scan cycle, while in others, it may take several seconds.
1. Addition: The addition function is used to add two or more input signals and
produce an output signal that is the sum of the input signals. In PLC
programming, the addition function is usually denoted by the "+" symbol.
4. Division: The division function is used to divide one input signal by another
input signal and produce an output signal that is the quotient of the input
signals. In PLC programming, the division function is usually denoted by the "/"
symbol.
5. Increment and Decrement: The increment and decrement functions are used
to increase or decrease the value of a signal by a specified amount. In PLC
programming, the increment function is usually denoted by the "INC"
instruction, while the decrement function is usually denoted by the "DEC"
instruction.
1. AND Function: The AND function is used to combine two or more input
signals and produce an output signal that is true if all of the input signals are
true. In PLC programming, the AND function is usually denoted by the "AND"
instruction or symbol.
3. XOR Function: The XOR function is used to combine two input signals and
produce an output signal that is true if only one of the input signals is true. In
PLC programming, the XOR function is usually denoted by the "XOR" instruction
or symbol.
4. NOT Function: The NOT function is used to invert the state of an input signal
and produce an output signal that is the opposite of the input signal. In PLC
programming, the NOT function is usually denoted by the "NOT" instruction or
symbol.
1. Timer Address: The timer address is the memory location in the PLC where
the timer block is stored. This address is used to reference the timer block in the
PLC program.
2. Status Bits: The status bits are used to monitor the state of the timer block.
The status bits indicate whether the timer block is enabled, whether it is timing,
and whether the time duration has expired.
3. On Delay: The on delay function is used to start the timer block when an
input signal is received. The timer block continues to execute for a specific
duration before producing an output signal. The on delay function is denoted by
the "TON" instruction in ladder logic.
4. Off Delay: The off delay function is used to stop the timer block when an
input signal is no longer received. The timer block continues to execute for a
specific duration after the input signal is no longer received before producing an
output signal. The off delay function is denoted by the "TOF" instruction in
ladder logic.
To program a timer block in PLC programming, the following steps are typically
followed:
1. Determine the memory location where the timer block will be stored in the
PLC.
2. Define the on delay or off delay function of the timer block based on the
required behavior.
4. Monitor the status bits of the timer block to determine when the timer
duration has expired.
An up counter is a counter that increments its value on each clock cycle. For
example, a 4-bit up counter would start at 0000 and count up to 1111, after
which it would reset back to 0000.
A down counter is a counter that decrements its value on each clock cycle. For
example, a 4-bit down counter would start at 1111 and count down to 0000,
after which it would reset back to 1111.
Status bits are flags or bits in a register that provide information about the
status of a counter or other device. For example, a status bit might indicate
whether a counter has reached its maximum or minimum value.
The ladder logic for a simple traffic light controller would include two inputs,
one for a sensor detecting the presence of vehicles and another for a timer. The
output would be two lights, a red light and a green light. The ladder logic would
be as follows:
Sensor Input: X0
Timer Input: T0
| X0 | T0 | Output_Y0 | Output_Y1 |
|-------|-------|-------------|-------------|
|0|0|1|0|
|1|0|0|1|
|0|1|0|1|
|1|1|1|0|
The ladder logic for an automatic door control system would include one input
for a sensor detecting the presence of a person and an output controlling the
door motor. The ladder logic would be as follows:
Sensor Input: X0
| X0 | Output_Y0 |
|-------|-------------|
|0|0|
|1|1|
The ladder logic for a conveyor belt control system would include one input for
a sensor detecting the presence of an object and two outputs controlling the
motor direction. The ladder logic would be as follows:
Sensor Input: X0
| X0 | Output_Y0 | Output_Y1 |
|-------|-------------|-------------|
|0|0|0|
|1|1|0|
|0|0|1|
|1|0|0|
These are just a few examples of ladder logic for simple applications. The logic
for more complex systems will include additional inputs and outputs, as well as
more complex combinations of ladder rungs
INSTALLATION AND MAINTENANCE OF PLC SYSTEMS
Installation:
1. Choose the right PLC for the application: Select a PLC that meets the system's
requirements and specifications.
2. Prepare the installation site: Choose a clean, dry, and dust-free area. Ensure
that there is adequate ventilation, and the temperature and humidity levels are
within the specified range.
3. Install the PLC hardware: Mount the PLC, power supply unit, I/O modules,
and other components on the rack or cabinet.
4. Connect the hardware: Connect the PLC to the power supply, field devices,
and other equipment using appropriate cables and connectors.
Maintenance:
1. Regular inspection: Check the PLC system for any signs of damage or wear
and tear regularly.
2. Keep the system clean: Dust and debris can clog up the PLC components and
affect performance. Keep the system clean, dry, and well-ventilated.
3. Backup the program: Regularly backup the PLC program and store it in a safe
location to avoid data loss in case of system failure.
4. Check the power supply: Ensure that the power supply to the PLC system is
stable and consistent. Any fluctuations can cause damage to the system.
5. Monitor the system performance: Monitor the system performance, including
temperature, CPU usage, and I/O operations, to detect any anomalies or issues.
The PLC enclosure is a critical component in protecting the PLC system from
environmental factors such as dust, moisture, and temperature variations. It
also helps in reducing electromagnetic interference (EMI) and radio frequency
interference (RFI). Here are some points to consider:
2. It should have proper sealing to prevent dust and moisture from entering the
enclosure.
3. The enclosure should have ventilation to dissipate the heat generated by the
PLC system.
Grounding Requirements:
Grounding is essential to ensure the safety and proper operation of the PLC
system. Here are some guidelines:
1. The PLC and all connected devices should be properly grounded to prevent
electrical shock and damage to the equipment.
2. The ground wire should be connected to a reliable ground point, such as a
building ground or a dedicated grounding rod.
3. The ground wire should be of appropriate size and material to handle the
current and resist corrosion.
4. The ground wire should be routed away from power cables to prevent
induction.
1. Install a noise filter between the inductive device and the PLC input or output.
2. Use shielded cables to connect the inductive device to the PLC input or
output.
3. Use twisted pair cables to reduce the noise generated by the inductive device.
Leaky inputs and outputs can cause false triggering and affect the performance
of the PLC system. Here are some techniques to reduce leakage:
3. Use a higher voltage to drive the input or output to overcome the leakage
current.
Hardware Troubleshooting:
1. Check the power supply: Verify that the power supply is providing the correct
voltage and current to the PLC system.
2. Check the wiring: Verify that all wiring connections are secure and free from
any damage orcorrosion.
3. Check the I/O modules: Verify that the I/O modules are functioning correctly
and are communicating with the PLC system.
5. Check the PLC module: Verify that the PLC module is functioning correctly,
and its firmware is up-to-date.
Software Troubleshooting:
1. Check the program: Verify that the PLC program is correct and that there are
no errors or bugs.
2. Check the memory: Verify that there is enough memory available to run the
program correctly.
3. Check the software settings: Verify that the software settings are correct,
including communication settings, I/O addressing, and timers.
4. Check the communication protocol: Verify that the communication protocol is
correct and compatible with the devices used in the system.
5. Check for software conflicts: Verify that there are no conflicts with other
software or applications running on the same device.
Maintenance:
1. Check the physical condition: Regularly inspect the PLC system for any
physical damage, wear and tear, or signs of overheating.
2. Backup the program: Regularly backup the PLC program to prevent data loss
in case of system failure.
3. Clean the system: Regularly clean the PLC system, including the enclosure and
components, to prevent dust and debris build-up.
4. Update the firmware: Regularly update the firmware of the PLC module and
other components to ensure optimal performance and compatibility.
5. Train personnel: Ensure that personnel responsible for the PLC system's
maintenance and troubleshooting receive proper training and have the
necessary skills to handle the system correctly.
The following are some common diagnostic LED indicators that are found on PLC
systems:
1. Power LED: This LED indicates whether the system is receiving power. If the
LED is not lit, it may indicate that the power supply is not working correctly, or
there is a problem with the wiring.
2. Run LED: This LED indicates whether the PLC program is running. If the LED is
not lit, it may indicate that there is a problem with the PLC program, the
memory, or the processor.
3. Fault LED: This LED indicates that there is an error or fault in the system. The
fault LED may flash a specific sequence that can help diagnose the problem.
4. I/O LED: This LED indicates the status of the input and output modules. If an
input or output module is not functioning correctly, the LED may indicate which
module is experiencing the issue.
6. Programming LED: This LED indicates the status of the programming mode. If
the programming LED is lit, it may indicate that the PLC system is in
programming mode.
7. System Status LED: This LED indicates the overall status of the PLC system. If
there is a problem with the system, the LED may indicate which area of the
system is experiencing the issue.
1. Check the PLC power supply: Verify that the power supply to the PLC is stable
and within the specified voltage range. Use a multimeter to measure the
voltage and ensure that it matches the recommended value.
2. Emergency push button: Test the emergency push button to ensure that it is
functioning properly. Press the button and check if the PLC responds as
expected.
3. Power supply failure: If there is a power supply failure, check the wiring and
connections to ensure they are secure. If necessary, replace the power supply
unit.
4. Battery failure: If the PLC uses a battery, check the battery voltage and
replace it if necessary. It is recommended to replace batteries on a regular
schedule to prevent failures.
6. Verify the PLC program with the master program: Compare the PLC program
with the master program to ensure that they match. This can be done using
software tools that allow comparison and verification of program code.
1. Power failure: If there is a power failure, check the power supply and wiring
to ensure they are functioning correctly. Use an uninterruptible power supply
(UPS) to provide backup power and prevent data loss.
2. Faulty grounding: Check the grounding of the system and ensure that it meets
the recommended standards. Use grounding techniques to reduce electrical
noise and interference.
4. Status of output modules and associated circuitry: Check the output modules
and their associated circuitry to ensure they are functioning correctly. Test the
output signals and check that they match the expected values.
5. Status of input modules and associated circuitry: Check the input modules
and their associated circuitry to ensure they are functioning correctly. Test the
input signals and check that they match the expected values.
6. Field input and output devices: Check the field input and output devices to
ensure they are functioning correctly. Test the devices and check that they are
sending and receiving data correctly.
1. Humidity: Check the humidity levels in the area surrounding the PLC. Use a
hygrometer to measure the humidity level and compare it with the
recommended range specified by the manufacturer. If the humidity levels are
outside the recommended range, use a dehumidifier or humidifier to adjust the
levels accordingly.
3. Vibration: Check for any sources of vibration that may affect the performance
of the PLC. Use a vibration meter to measure the levels of vibration and
compare it with the recommended range specified by the manufacturer. If the
levels are outside the recommended range, adjust the placement of the PLC or
use vibration-dampening materials to reduce the impact of vibration.
4. Noise level: Check the noise levels in the area around the PLC. Use a decibel
meter to measure the noise level and compare it with the recommended range
specified by the manufacturer. If the noise level is outside the recommended
range, use noise-reducing materials or relocate the PLC to a quieter area.
• Replacement of CPU
Here are some troubleshooting steps that can be taken for specific components
of the PLC system:
1. Power supply troubleshooting: Check the voltage and current output of the
power supply. If there are issues, check the wiring and connections to ensure
they are secure. If necessary, replace the power supply unit.
2. I/O modules troubleshooting: Test the I/O modules and their associated
circuitry to ensure they are functioning correctly. If there are issues, check the
wiring and connections to ensure they are secure. Use diagnostic tools to
identify and resolve I/O module issues.
3. PLC program errors troubleshooting: Identify the source of the program error
by reviewing the error messages and diagnostic codes. Check the PLC program
for errors, such as syntax errors or logical errors, and correct them as needed.
Test the program and check that it is functioning as expected.
1. Identify the problem: Determine the symptoms of the problem and gather
information on the system's history, operating conditions, and any recent
changes or incidents.
2. Check the power supply: Ensure that the power supply is working correctly
and providing the required voltage and current to the system.
3. Check the I/O modules: Test the input and output modules to ensure they are
functioning correctly. Check the wiring and connections to ensure they are
secure.
4. Check the PLC program: Identify any errors in the program, such as syntax or
logic errors. Test the program and check that it is functioning as expected.
7. Test the system: Test the system to ensure that the problem has been
resolved and that the PLC is functioning correctly.
By following this flowchart, issues with the PLC system can be identified and
resolved systematically, ensuring reliable performance of the system.
1. Keep the system clean: Regularly clean the PLC system to prevent dust and
debris from accumulating and affecting its functioning.
2. Check the power supply: Regularly check the power supply to ensure that it is
providing the required voltage and current to the system.
3. Check the I/O modules: Regularly test the input and output modules to
ensure they are functioning correctly. Check the wiring and connections to
ensure they are secure.
4. Check the PLC program: Regularly review the PLC program to ensure that it is
up-to-date and functioning correctly. Make any necessary updates or changes to
the program as needed.
A preventive maintenance procedure for the PLC system should include regular
checks and maintenance of the system components. Here are some steps that
can be taken for a preventive maintenance procedure:
3. Test the I/O modules: Regularly test the input and output modules to ensure
they are functioning correctly.
4. Review and test the PLC program: Regularly review and test the PLC program
to ensure that it is up-to-date and functioning correctly.
A maintenance plan for the PLC system should include a detailed schedule of
maintenance checks and procedures. Here are some steps that can be taken for
a maintenance plan for the PLC system:
5. Review and adjust the maintenance plan: Regularly review the maintenance
plan to ensure that it is effective and make any necessary adjustments or
updates to the plan.
2. Personal Protective Equipment (PPE): PPE, such as safety glasses, gloves, and
protective clothing, should be worn by personnel working with or around the
PLC system.
4. Warning Labels and Signs: Warning labels and signs should be placed on the
system to indicate potential hazards and remind personnel of safety
procedures.
8. Safety Relays: Safety relays should be used to monitor the system for
potential safety hazards and to shut down the system if necessary.
9. Training: Personnel working with or around the PLC system should receive
proper training on the system's safety procedures and equipment.
By using these safety procedures and equipment, the risk of accidents and
injuries in PLC systems can be greatly reduced, ensuring the safety of personnel
and the efficient functioning of the system.
SCADA and DCS
SCADA (Supervisory Control and Data Acquisition) and DCS (Distributed Control
System) are two types of industrial control systems that are commonly used in
manufacturing and industrial processes.
SCADA systems are used to monitor and control large-scale processes such as
water and wastewater treatment, power generation and transmission, and oil
and gas pipelines. They typically consist of a centralized computer system that
collects data from sensors and other devices located throughout the process,
and uses that data to monitor and control the process.
DCS systems, on the other hand, are typically used to control smaller-scale
processes such as chemical production, food processing, and pharmaceutical
manufacturing. DCS systems consist of multiple controllers that are distributed
throughout the process and are connected to a central computer system.
While both SCADA and DCS systems are used for process control, there are
some key differences between them. SCADA systems are typically used for
large-scale, geographically dispersed processes, while DCS systems are more
commonly used for smaller, localized processes. Additionally, SCADA systems
are often used in industries that require real-time monitoring and control, such
as power generation and transmission, while DCS systems are often used in
industries that require precise control of manufacturing processes.
Overall, both SCADA and DCS systems are critical components of modern
industrial processes, and are essential for ensuring efficient and safe operation
of these processes.
Need:
The need for SCADA and DCS systems arises from the growing complexity of
industrial processes, which require real-time monitoring and control for
effective management. These systems enable operators to remotely monitor
and control various industrial processes from a central location, allowing for
faster decision-making, reduced downtime, and improved safety.
Benefits:
3. Enhanced safety: SCADA and DCS systems can help identify potential safety
issues before they become a problem, allowing operators to take corrective
action before any harm occurs.
4. Better data management: SCADA and DCS systems collect and store large
amounts of data, which can be used for analysis and optimization of industrial
processes.
Typical Applications:
1. Power generation and distribution: SCADA systems are used to monitor and
control power generation and distribution processes, ensuring safe and efficient
operation.
2. Water and wastewater treatment: SCADA systems are used to manage water
treatment processes, ensuring clean and safe water for communities.
3. Oil and gas pipelines: SCADA systems are used to monitor and control oil and
gas pipelines, ensuring the safe transportation of these resources.
Overall, SCADA and DCS systems are critical components of modern industrial
processes, and are essential for ensuring efficient and safe operation of these
processes.
1. Remote Terminal Unit (RTU): The RTU is responsible for collecting data from
various sensors and devices located in the field and sending it to the Master
Terminal Unit (MTU) for processing.
2. Master Terminal Unit (MTU): The MTU is responsible for processing the data
received from the RTUs, providing control signals to the RTUs, and displaying
the processed data to the system operator.
3. SCADA Editor: The SCADA Editor is a software tool used to create, edit, and
configure the graphical user interface (GUI) for the SCADA system.
The RTUs are typically located in the field and are responsible for acquiring data
from sensors and other devices, such as pumps, valves, and motors. The RTUs
then process this data and send it to the MTU for further processing. The MTU is
typically located in a central control room and is responsible for processing the
data received from the RTUs, providing control signals to the RTUs, and
displaying the processed data to the system operator.
The SCADA Editor is used to create and configure the graphical user interface
(GUI) for the SCADA system. This allows the operator to monitor and control the
system using an intuitive and easy-to-use interface. The SCADA Editor is also
used to configure alarms, setpoints, and other parameters for the system.
1. Scale and Scope: SCADA systems are typically used for large-scale,
geographically dispersed processes, while DCS systems are more commonly
used for smaller, localized processes. SCADA systems can monitor and control
entire plant-wide systems, such as water treatment, power generation, and oil
and gas pipelines. DCS systems, on the other hand, are used for controlling
specific processes, such as chemical production, food processing, and
pharmaceutical manufacturing.
3. Level of Control: SCADA systems are often used in industries that require
real-time monitoring and control, such as power generation and transmission.
DCS systems, on the other hand, are often used in industries that require
precise control of manufacturing processes.
5. Integration with Other Systems: SCADA systems are often used in conjunction
with other control systems, such as Programmable Logic Controllers (PLCs) and
Distributed I/O systems. DCS systems, on the other hand, are typically
integrated with other DCS systems and do not require the same level of
integration with other control systems.
Overall, both SCADA and DCS systems are critical components of modern
industrial processes and are essential for ensuring efficient and safe operation
of these processes. However, their specific differences in scale, control
architecture, level of control, HMI design, and integration with other systems
make them better suited for different types of industrial applications.
The PLC is responsible for controlling the various field devices, such as sensors,
actuators, and motors. The PLC collects data from the field devices and sends it
to the SCADA system, which is responsible for displaying the data in a graphical
user interface (GUI) and providing the operator with control over the process.
1. PLC: The PLC is responsible for controlling the field devices and collecting data
from them.
3. SCADA System: The SCADA system is responsible for displaying the data
collected by the PLC and providing the operator with control over the process.
4. HMI: The HMI (Human Machine Interface) is the graphical user interface used
by the operator to interact with the SCADA system. The HMI typically includes
displays of process variables, such as temperature, pressure, and flow rate, as
well as control elements, such as switches and buttons.
1. OPC Client: The OPC client is the software application that uses OPC to access
data and functionality from other control systems.
2. OPC Server: The OPC server is the software application that provides data and
functionality to the OPC client. The OPC server acts as a bridge between the
control system and the OPC client.
3. OPC Object: The OPC object is a software component that represents a
specific process variable or control function in the control system. The OPC
object provides the OPC server with access to the data or functionality it
represents.
Creating SCADA Screen HMI for simple object, Steps for linking
SCADA object (defining Tags and items, creating trends etc.,) with PLC
ladder program using OPC, configuring simple applications using
SCADA: Traffic light control, water distribution, pipeline control,
Power generation, transmission and distribution etc.
Creating a SCADA HMI screen for a simple object involves the following steps:
1. Define Tags: Define tags that correspond to the data points you want to
monitor and control in the PLC ladder program. Tags can be defined as numeric,
string, Boolean, or other data types.
2. Create Items: Create items in the SCADA software that correspond to the tags
defined in the PLC ladder program. Items can be graphical representations of
data points, such as meters, gauges, or digital readouts.
4. Link Items to Tags: Link the items created in the SCADA software to the tags
defined in the PLC ladder program. This allows the SCADA software to read and
write data to the PLC.
For example, to create a SCADA application for a traffic light control system, the
following steps could be taken:
1. Define Tags: Define tags for the various components of the traffic light
system, such as the red, yellow, and green lights, as well as the pedestrian walk
signal.
2. Create Items: Create items in the SCADA software that correspond to the
tags, such as graphical representations of the lights and pedestrian signal.
4. Link Items to Tags: Link the items created in the SCADA software to the tags
defined in the PLC ladder program.
5. Create Trends: Create trends to monitor changes in the state of the traffic
lights and pedestrian signal over time.
Similar steps can be taken to create SCADA applications for water distribution,
pipeline control, power generation, transmission, and distribution systems, with
appropriate tags and items defined for each application. The key is to define the
tags in the PLC ladder program and link them to the corresponding items in the
SCADA software using OPC communication.
By following these maintenance procedures, the SCADA based PLC system can
be kept running smoothly and efficiently, and any issues can be detected and
resolved quickly, minimizing downtime and ensuring that the system is always
available to provide the necessary monitoring and control functions
Applications of Industrial Automation
Here are some examples of how industrial automation can be applied in these
areas:
3. Pick and Place Robots: Pick and place robots are commonly used in the
packaging and logistics industries to pick up and move items from one location
to another. These robots can handle a variety of items of different sizes and
shapes and can be programmed to work with a range of packaging materials.
3. AESOP and 2EVS: AESOP and 2EVS are robotic systems used in minimally
invasive surgery. AESOP (Automated Endoscopic System for Optimal
Positioning) is a robotic arm that holds and moves an endoscope, allowing the
surgeon to perform surgery with greater precision and control. 2EVS
(Two-Endoscope Vision System) is a similar system that uses two endoscopes to
provide the surgeon with a 3D view of the surgical site.
4. RP-7 (Remote Presence 7th Generation): RP-7 is a remote presence robot that
allows healthcare providers to interact with patients remotely. This robot can
be used to monitor patients in hospitals or nursing homes, or to provide care to
patients in remote locations.
1. Guided Rockets and Missiles: Guided rockets and missiles are weapons that
use advanced guidance systems to improve their accuracy and effectiveness.
These systems can be designed to home in on a target using a variety of sensors,
including radar, infrared, and GPS. Industrial automation can be used to
manufacture and assemble these weapons to ensure they meet the required
specifications and are of high quality.
3. VAV Drones Launcher: VAV (Vertical Aerial Vehicle) drones are unmanned
aerial vehicles that can be used for reconnaissance, surveillance, and other
military applications. Industrial automation can be used to manufacture and
assemble VAV drone launchers that can be used to deploy these drones quickly
and efficiently.
1. Harvesters: Harvesters are machines used for harvesting crops such as wheat,
rice, and corn. Industrial automation can be used to design and manufacture
these machines to ensure they are efficient and effective.
3. Plowing Machines: Plowing machines are used to till the soil and prepare it
for planting. Industrial automation can be used to design and manufacture
these machines to ensure they are efficient and effective.
5. Grain Yield Sensor: Grain yield sensors are used to measure the amount of
grain produced by a crop. Industrial automation can be used to design and
manufacture these sensors to ensure they are accurate, efficient, and reliable.
2. Mine Picture Compilation: Mine picture compilation systems use cameras and
sensors to create 3D models of the mine. Industrial automation can be used to
design and manufacture these systems to ensure they are accurate and
efficient.
3. Mine Control System: Mine control systems use sensors and software to
monitor and control the operations of the mine. Industrial automation can be
used to design and manufacture these systems to ensure they are safe, efficient,
and reliable.
5. Laser Imaging: Laser imaging systems use lasers to create 3D images of the
mine. Industrial automation can be used to design and manufacture these
systems to ensure they are accurate and efficient.
6. Rig Control System: Rig control systems use sensors and software to monitor
and control the operations of drilling rigs. Industrial automation can be used to
design and manufacture these systems to ensure they are safe, efficient, and
reliable.