REINFORCEMENT DETAILS
REINFORCEMENT DETAILS
3450
BASE 1 BASE 1
BASE 1
BASE 1
2300
2300
9700
9700
200 2200 5400 200 5500 200 200 5500 200 5400 2200 200
BASE 1
BASE 1
3950
600 X 200 RC FOOTING 600 X 200 RC FOOTING
200 2100 200 3000 200 2100 200 5500 200 5500 200 2100 200 3000 200 2100 200
27200
FOUNDATION LAYOUT
SCALE 1:100
C.C C.C
DEC 2017
SCALE: AS SHOWN 1 OF 8
CHIN/STR/12-17/001 00
NOTE:
16R8-05 1. THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH ALL OTHER RELEVANT DRAWINGS.
2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED.
3. ALL SETTING OUT DIMENSIONS ARE TO BE
VERIFIED ON SITE PRIOR TO COMMENCING
75 KICKER
WORKS.
150
4. PROGRAM, METHOD OF CONSTRUCTION AND
SETTING OUT OF THE WORKS SHALL BE APPROVED
BY THE ENGINEER BEFORE COMMENCEMENT OF
14R8-05 WORK.
250
SLAB LEVEL
5. OBTAIN ALL DIMENSIONS FROM SHOWN FIGURES.
DO NOT SCALE OFF.
6. ALL REINFORCEMENT TO BE INSPECTED BY THE
ENGINEER PRIOR TO POURING CONCRETE.
300
7. ALL REINFORCED CONCRETE WORKS TO BE DONE
GROUND LEVEL IN ACCORDANCE WITH THE ENGINEER'S
-10- -10- SPECIFICATIONS ON STRUCTURAL CONCRETE.
C/C
8. ALL REINFORCED CONCRETE WORKS TO BE DONE
IN ACCORDANCE WITH BS 8110 PARTS I, II & III OF
200
1997.
-11- -11-
R8@
9. THE CONTRACTOR IS RESPONSIBLE FOR
6R8-05-200
PROVIDING ALL SPACER BLOCKS, CHAIRS AND
TYING WIRE.
-10- -10- 10. ALL STRUCTURAL CONCRETE TO BE CLASS 25. 50
800
mm BLINDING CONCRETE TO BE CLASS 15.
4Y16-03 11. MINIMUM COVER TO REINFORCEMENT TO BE: 25
SECTION 4 - 4 2Y12-04 mm FOR ALL CONCRETE.
1100
SCALE 1:25 12. MAXIMUM AGGREGATE SIZE TO BE 20 mm.
2 2
3000
-02-
4 4
3050
300
2650
4Y16-08 -06- -06- -01-
C/C
+2Y12-09
500 200 500
200
-07- -07- 4Y16-10
R8@
1200
+2Y12-11
-06- -06-
SECTION 1 - 1
SCALE 1:25
SECTION 3 - 3
SCALE 1:25
7Y12-02-200 B2
75 KICKER
75 KICKER
400
6050
150
Y16 Y16
C/C
14R8-05 Starter bar 1 1
250
200
1200
400
200 Y12 Y12
R8@
Y16 Y16
COLUMN C2
SCALE 1:25
400
7Y12-01-200 B1
3 3 Conforce 86 mesh
300
4Y16-06
+2Y12-07 GROUND LEVEL
800
200
DEC 2017
3450
mm BLINDING CONCRETE TO BE CLASS 15.
11. MINIMUM COVER TO REINFORCEMENT TO BE: 25
mm FOR ALL CONCRETE.
12. MAXIMUM AGGREGATE SIZE TO BE 20 mm.
C2 C2
C2 C2 C2 C2
1
IT
H CO25m
W TOP NF m T
C EDHE OR HI
R T CE CK
FO N
2300
2300
86 CO
IN H O M NC
RE S
9700
9700
ES R
A B ME H ET
6
SL E 8 ON E
S
TE RC TH LA
RE FO E BR
C N TO E
N O P INF
C2 CO C OR C2
K C2 C2
IC CE
TH D
W
5 mm IT
H
12
3950
3950
C1 C1 C1 C1
200 2100 200 3000 200 2100 200 5600 5600 200 2100 200 3000 200 2100 200
27200
300
DEC 2017
SCALE: AS SHOWN 3 OF 8
CHIN/STR/12-17/001 00
NOTE:
1. THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH ALL OTHER RELEVANT DRAWINGS.
Y 2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED.
2640
3. ALL SETTING OUT DIMENSIONS ARE TO BE
1050 270 270 270 270 270 240 VERIFIED ON SITE PRIOR TO COMMENCING
2640 WORKS.
(2X2)Y12-11-150 T2/B2
4. PROGRAM, METHOD OF CONSTRUCTION AND
SETTING OUT OF THE WORKS SHALL BE APPROVED
1050 6 QUAL TREADS = 1620
200
BY THE ENGINEER BEFORE COMMENCEMENT OF
WORK.
5. OBTAIN ALL DIMENSIONS FROM SHOWN FIGURES.
DO NOT SCALE OFF.
6. ALL REINFORCEMENT TO BE INSPECTED BY THE
176
6Y12-08-200 UB ENGINEER PRIOR TO POURING CONCRETE.
(3) (3) 6Y12-05-200 T2 - 7. ALL REINFORCED CONCRETE WORKS TO BE DONE
-05 IN ACCORDANCE WITH THE ENGINEER'S
SFL
176
SPECIFICATIONS ON STRUCTURAL CONCRETE.
3050 SEE BEAM B04
8. ALL REINFORCED CONCRETE WORKS TO BE DONE
SFL
9Y12-05-200 B2 -10- IN ACCORDANCE WITH BS 8110 PARTS I, II & III OF
1760
176
1050
9. THE CONTRACTOR IS RESPONSIBLE FOR
1100
176
10. ALL STRUCTURAL CONCRETE TO BE CLASS 25. 50
X X mm BLINDING CONCRETE TO BE CLASS 15.
11. MINIMUM COVER TO REINFORCEMENT TO BE: 25
-06-
176
mm FOR ALL CONCRETE.
- 12. MAXIMUM AGGREGATE SIZE TO BE 20 mm.
- -05
-07- -05
176
176
-01-
270
150
(3)
6Y12-09-200
270
-09-
SCALE 1:25
270
270
215 1100 270 270 270 270 270 270 270 270 270
270
-11- -06-
-09-
UP
270
6Y12-08-200 UB
150
176
-0
5-
-11- -07-
176
6Y12-02-200
270
176
(3)
270
176
15Y12-05-200 B2 6Y12-05-200 T2
1610
-05
176
-
176
1050
-0 -02-
5-
176
-01-
STAIRCASE PLAN - REINFORCEMENT DETAILS, 2No. THUS
176
SCALE 1:25 2Y12-03
176
125
150
6R8-04-200
2Y12-03
C.C C.C
DEC 2017
SCALE: AS SHOWN 4 OF 8
CHIN/STR/12-17/001 00
NOTE:
1. THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH ALL OTHER RELEVANT DRAWINGS.
2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED.
3. ALL SETTING OUT DIMENSIONS ARE TO BE
VERIFIED ON SITE PRIOR TO COMMENCING
WORKS.
4. PROGRAM, METHOD OF CONSTRUCTION AND
SETTING OUT OF THE WORKS SHALL BE APPROVED
BY THE ENGINEER BEFORE COMMENCEMENT OF
WORK.
5. OBTAIN ALL DIMENSIONS FROM SHOWN FIGURES.
DO NOT SCALE OFF.
6. ALL REINFORCEMENT TO BE INSPECTED BY THE
ENGINEER PRIOR TO POURING CONCRETE.
7. ALL REINFORCED CONCRETE WORKS TO BE DONE
IN ACCORDANCE WITH THE ENGINEER'S
400 X 200 RC RING BEAM 400 X 200 RC RING BEAM SPECIFICATIONS ON STRUCTURAL CONCRETE.
SFL 2600 SFL 2600 8. ALL REINFORCED CONCRETE WORKS TO BE DONE
IN ACCORDANCE WITH BS 8110 PARTS I, II & III OF
300 X 200 RC BEAM 07 300 X 200 RC BEAM 07
1997.
9. THE CONTRACTOR IS RESPONSIBLE FOR
SFL 2600
mm BLINDING CONCRETE TO BE CLASS 15.
11. MINIMUM COVER TO REINFORCEMENT TO BE: 25
mm FOR ALL CONCRETE.
12. MAXIMUM AGGREGATE SIZE TO BE 20 mm.
VOID VOID
15
I L
TA
0m
DE
m
TH
TO
I
CK
T
EN
CO
M
NC
CE
RE
400 X 200 RC BEAM B02 400 X 200 RC BEAM B02
OR
TE
NF
SL
I
RE
AB
B
RE
A
SL
IN
TE
FO
400 X 200 RC RING BEAM
RC
400 X 200 RC BEAM B01
EM
CO
EN
K
T
IC
TO
TH
DE
m
0m
TA
15
IL
400 X 200 RC RING BEAM 400 X 200 RC RING BEAM 400 X 200 RC RING BEAM 400 X 200 RC RING BEAM
200 2100 200 3000 200 2100 200 5600 5600 200 2100 200 3000 200 2100 200
27200
3Y20-02
A
02 02 02
2Y16
150
150
150
400
C/C
20R8-03-200 C/C
250
C/C
200
400
R8@
200
400
R8@
250
250
A 3Y20-01
01 01 01
200 2Y16
200 3750 200 200
SECTION A - A 4150
C.C C.C
DEC 2017
SCALE: AS SHOWN 5 OF 8
CHIN/STR/12-17/001 00
NOTE:
1. THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH ALL OTHER RELEVANT DRAWINGS.
2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED.
3. ALL SETTING OUT DIMENSIONS ARE TO BE
VERIFIED ON SITE PRIOR TO COMMENCING
WORKS.
4Y20-05 B
05 05 05 05
4. PROGRAM, METHOD OF CONSTRUCTION AND
SETTING OUT OF THE WORKS SHALL BE APPROVED
150
BY THE ENGINEER BEFORE COMMENCEMENT OF
150
C/C
WORK.
500
200
38R8-03a-200 C/C (19) (8) (11)
350
5. OBTAIN ALL DIMENSIONS FROM SHOWN FIGURES.
R8@
500
04a 04a DO NOT SCALE OFF.
350
2Y12-04a 4Y20-04
6. ALL REINFORCEMENT TO BE INSPECTED BY THE
B ENGINEER PRIOR TO POURING CONCRETE.
7. ALL REINFORCED CONCRETE WORKS TO BE DONE
200 3700 200 1400 200 2100 200
04 04 04 04 IN ACCORDANCE WITH THE ENGINEER'S
8000
200
SPECIFICATIONS ON STRUCTURAL CONCRETE.
SECTION B - B 400 X 200 BEAM 02 8. ALL REINFORCED CONCRETE WORKS TO BE DONE
SCALE 1:15 SCALE 1:25 IN ACCORDANCE WITH BS 8110 PARTS I, II & III OF
1997.
9. THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL SPACER BLOCKS, CHAIRS AND
TYING WIRE.
10. ALL STRUCTURAL CONCRETE TO BE CLASS 25. 50
C 3Y20-07
07 07 07
mm BLINDING CONCRETE TO BE CLASS 15.
11. MINIMUM COVER TO REINFORCEMENT TO BE: 25
150
150
mm FOR ALL CONCRETE.
400
C/C
(11)
39R8-03-200 C/C (28)
12. MAXIMUM AGGREGATE SIZE TO BE 20 mm.
250
200
400
R8@
250
3Y20-06
C
06 06 06
200
200 5200 400 2000 200
SECTION C - C 8000
SCALE 1:15
D 3Y20-09
09 09 09
150
150
400
C/C
29R8-03-200 C/C (17) (12)
250
200
400
R8@
250
3Y20-08
D
08 08 08
200
200 3250 200 2100 200
SECTION D - D 5950
SCALE 1:15
E 3Y20-26
26 26
25R8-27-200 C/C
C/C
350
200
350
R8@
3Y20-26
E
26 26 26
200
F 2Y16-28
28 28
C/C
300
17R8-29-200 C/C
00
300
@2
R8
3Y16-28
F
28 28 28
200
SECTION F - F
350 3250 200
SCALE 1:15
3800
G 2Y12-30
30 30
C/C
300
10R8-29-200 C/C
00
300
@2
R8
2Y12-30
G
30 30
200
DEC 2017
SCALE: AS SHOWN 6 OF 8
CHIN/STR/12-17/001 00
NOTE:
1. THIS DRAWING IS TO BE READ IN CONJUNCTION
WITH ALL OTHER RELEVANT DRAWINGS.
2. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS
OTHERWISE STATED.
3. ALL SETTING OUT DIMENSIONS ARE TO BE
VERIFIED ON SITE PRIOR TO COMMENCING
WORKS.
4. PROGRAM, METHOD OF CONSTRUCTION AND
SETTING OUT OF THE WORKS SHALL BE APPROVED
BY THE ENGINEER BEFORE COMMENCEMENT OF
WORK.
7800 5700 5700 7800
5. OBTAIN ALL DIMENSIONS FROM SHOWN FIGURES.
DO NOT SCALE OFF.
2100 200 5300 200 5500 200 5500 200 5300 200 2100 200 6. ALL REINFORCEMENT TO BE INSPECTED BY THE
ENGINEER PRIOR TO POURING CONCRETE.
(2X26) Y16-21-150 (T1/B1)
7. ALL REINFORCED CONCRETE WORKS TO BE DONE
(2x3)Y16-21a (T1/B1) (2x3)Y16-21a (T1/B1)
(2X22) Y10-23-150 (T2/B2) (2X22) Y10-23-150 (T2/B2) IN ACCORDANCE WITH THE ENGINEER'S
18R8-24-200 LINKS (2X26) Y16-21-150 (T1/B1) 18R8-24-200 LINKS SPECIFICATIONS ON STRUCTURAL CONCRETE.
8. ALL REINFORCED CONCRETE WORKS TO BE DONE
IN ACCORDANCE WITH BS 8110 PARTS I, II & III OF
10R8-25-200 LINKS 10R8-25-200 LINKS 1997.
9. THE CONTRACTOR IS RESPONSIBLE FOR
PROVIDING ALL SPACER BLOCKS, CHAIRS AND
(2X9)Y10-20-150 (T2/B2) (3) (6) (6) (3) (2X9)Y10-20-150 (T2/B2)
TYING WIRE.
(2X44) Y12-22-150 (T1/B1) (2X44) Y12-22-150 (T1/B1) 10. ALL STRUCTURAL CONCRETE TO BE CLASS 25. 50
(2X4)Y16-20a (T2/B2) (8) (36) (36) (8) (2X4)Y16-20a (T2/B2)
mm BLINDING CONCRETE TO BE CLASS 15.
11. MINIMUM COVER TO REINFORCEMENT TO BE: 25
3850
mm FOR ALL CONCRETE.
3450
VOID VOID
2300
2200
10000
(15) (18) (2X33) Y12-17-150 (T1/B1) (2X33) Y12-17-150 (T1/B1) (18) (15)
9700
A A A A
3950
3950
(2X26)Y12-14-150 (T1/B1) (2X26) Y12-13-150 (T1/B1) (2X26) Y12-13-150 (T1/B1) (2X26)Y12-14-150 (T1/B1)
22Y10-11-150 T2 22Y10-11-150 T2
(11) (11) (11) (11)
22Y10-11-150 B2 22Y10-11-150 B2
7Y12-10-150 B1 7Y12-10-150 B1
7Y10-10a-150 T1 7Y10-10a-150 T1
200 2100 200 3000 200 2100 200 5600 5600 200 2100 200 3000 200 2100 200
27200
-12- -12-
-14- -13-
150
C/C
C/C
C/C
200
200
200
-14- -13-
400
-12- -12-
R8@
R8@
R8@
250
8000
SECTION A - A
SCALE 1:25
C.C C.C
DEC 2017
SCALE: AS SHOWN 7 OF 8
CHIN/STR/12-17/001 00