Data sheet

testo 816-1

Sound level meter

testo 816-1 – Sound level measurement


with integrated data storage

Sound level measurement acc. to IEC 61672-1 class 2


and ANSI S1.4 Type 2 dB

Frequency weighting A and C

Integrated data storage for up to 31000 measurement


values

Software for data management and long-term measurement

Switchable time weighting Fast/Slow

Bar graph display

Backlit display

AC and DC output for the connection of other intruments

The testo 816-1 is ideal for sound level measurements The integrated data memory allows the storage of over
at workplaces, in industrial and production halls, and in 30,000 measurement values in the instrument, which can be
public places. With the touch of a button, the measuring managed using the convenient PC software (download from
instrument can be switched from Slow (1 sec.) to Fast www.testo.com). In addition to this, the software allows
(125 ms). It is also possible to switch between the online measurements over a longer period to be carried out.
frequency weighting characteristic curves A and C and vice With the optional sound calibrator and the adjustment
versa, also at the touch of a button. Characteristic curve A accessory included with it, the testo 816-1 can be re-
corresponds to the sound pressure sensitivity of the human calibrated on site.
ear, while characteristic curve C can evaluate low-frequency
components of a noise.

www.testo.com
testo 816-1

Technical data / Accessories

Technical data testo 816-1

testo 816-1 Measuring range 30 to 130 dB

Frequency range 20 Hz to 8 kHz


testo 816-1, sound level meter incl. microphone, Accuracy ±1.4 dB
wind protection, PC software, connection cable, ±1 digit (under reference conditions: 94 dB, 1 kHz)

0981 8974/msp/04.2024
manual and batteries in system case
Resolution 0.1 dB

Part no. 0563 8170 Frequency weighting A/C

Microphone ½ inch

Measuring rate 0.5 s

Dynamic range 100 dB

Data storage Internal (in instrument):


Single value memory: 99 data sets
Measurement series memory: 31,000 data sets
External (via PC software):
Technical data sound level calibrator Online measurement: max. 99,999 data sets
Battery type 9V block battery Recording rate Offline measurement: min: 1 sec, max: 1 min
Online measurement: min: 0.1 sec, max: 30 sec
Battery life 40 h
Operating temperature 0 to +40 °C
Accuracy ±0.5 dB in accordance with
Class 2 to IEC 60942 Storage temperature -10 to +60 °C

Sound pressure level: 94 dB/104 dB, switchable Battery type 4 x Type AA batteries
Frequency: 1000 Hz
Weight 390 g
Also suitable for ½ and 1 inch microphones by other manufacturers
Dimensions 272 x 83 x 42 mm

Time weighting FAST 125 ms / SLOW 1 sec

AC/DC output AC: 1 V RMS at full scale

Subject to change without notice.


DC: 10 mV/dB

Accessories for measuring instrument Part no.

Calibrator, for regular calibration of testo 815, testo 816-1 0554 0452

PC software testo 816-1 (download from www.testo.com) 0501 8170

ISO calibration certificate; sound level calibrators and pistonphones on two fixed sound pressure values 0520 2810

ISO calibration certificate pressure


Pressure chamber calibration – calibration at the measuring points 94 dB/1000 Hz and 114 dB/1000 Hz for up to
three frequency evaluations (A, C and Z) 0520 2812
Free-field calibration – calibration of the amplitude frequency response in the free field at fixed frequencies in third
interval. Possible frequency range 125 Hz to 20 kHz. 0520 2812
Free-field and pressure chamber calibration – calibration of the amplitude frequency response at fixed frequencies
in third interval. Possible frequency range 31.5 Hz up to 20 kHz. 0520 2812