IECEN 61215-2 Test Report
IECEN 61215-2 Test Report
Test results listed in this test report refer exclusively to the mentioned test sample.
The submitted test samples as described in the reports hereunder are based on the requirements:
IEC 61215-2:2016 / EN 61215-2:2017 + AC:2017 + AC:2018 “Terrestrial photovoltaic (PV) modules - Design
qualification and type approval - Part 2: Test procedures”
List of contents
List of contents..............................................................................................................................3
Summary of testing .......................................................................................................................4
General remarks ............................................................................................................................5
General product information ........................................................................................................6
Module type: SR-M672430HLP ...................................................................................................6
Module group assignment ............................................................................................................7
Module type: SR-M672430HLP ...................................................................................................7
Test result overview ......................................................................................................................8
Module type: SR-M672430HLP ...................................................................................................8
Test results of IEC / EN 61215-2 ...................................................................................................9
Module type: SR-M672430HLP ...................................................................................................9
4.1 Visual inspection (initial) - MQT01 ....................................................................................9
4.3 Insulation test (initial) - MQT03 .......................................................................................11
4.15 Wet leakage current test (initial) - MQT15 ....................................................................12
4.13 Damp heat 1000 test - MQT13 .....................................................................................13
Annex 1: List of measurement equipment.................................................................................16
Annex 2: Statement of the estimated uncertainty of the test results.......................................17
Annex 3: Photos ..........................................................................................................................18
Module type: SR-M672430HLP .................................................................................................18
Annex 4: Photos of insulation tape ............................................................................................20
Summary of testing
According to the enquiry of the applicant, a commission test was performed according to IEC 61215-2:2016.
Test items see page 7 for details.
Module type SR-M672430HLP was delivered to lab and was conducted with all the related tests.
All tests were successfully completed.
General remarks
Test item particulars:
Accessories and detachable parts included in the N/A
evaluation ................................................................. :
Options included ....................................................... : N/A
Abbreviations used in the report:
HF - Humidity Freeze TC - Temperature Cycling
DH - Damp Heat Vmpp - Maximum power voltage
Impp - Maximum power current Voc - Open circuit voltage
Isc - Short circuit current FF - Fill Factor
Pmpp - Maximum power α - Current temperature coefficient
NMOT - Nominal Module Operating Temperature β - Voltage temperature coefficient
STC - Standard Test Conditions γ - Power temperature coefficient
CTI - Comparative Tracking Index PTI - Proof Tracking Index
RTI - Relative Temperature Index RTE - Relative Thermal Endurance index
TI - Temperature Index DTI - Distance through insulation
Cl - Clearances Cr - Creepage distances
PD - Pollution Degree MG - Material Groups
Possible test case verdicts:
Test case does not apply to the test object .............. : Not Applicable (N/A)
Test object does meet the requirement .................... : Pass (P)
Test object does not meet the requirement .............. : Fail (F)
Other remarks:
The test verdicts presented in this report relate only to the object tested.
This report shall not be reproduced except in full, without the written approval of the issuing testing
laboratory.
Power degradation data expressed in negative value indicates a reduction of maximum power output.
Power degradation data expressed in positive value indicates an increment of maximum power output.
Sample 1# -
MQT13 Damp heat test (1000h) ..................................... : See table 4.13 P
4.15 Wet leakage current test (after damp heat 1000 test) - MQT15 -
Test date [MM/DD/YYYY]..................... : 11/02/2020 -
Test voltage applied [V] ........................ : 2 minutes of 1500 -
Solution resistivity [Ω/cm] / <3500 ....... : 2016 -
Solution temperature [°C] / 22±2 ......... : 22.4 -
Sample # Required [MΩ] Measured [MΩ] -
1 18.0 >1000 P
Supplementary information: Minimum requirement according to the standard is 40MΩ·m2. Area of the module is
2.22m2.
Annex 3: Photos
Module type: SR-M672430HLP
N/A
Sample #1 Sample #1
----- End of test report -----