0% found this document useful (0 votes)
33 views

D9859-Advanced-Receiver-Transcoder-SW-Version-1-10-Installation-and-Configuration-Guide

The document is an installation and configuration guide for the Cisco D9859 Advanced Receiver Transcoder Software Version 1.10, emphasizing the importance of reading the entire guide before use. It includes safety precautions, compliance information, and warranty disclaimers, highlighting the need to adhere to safety instructions to prevent hazards. Additionally, it provides guidelines for proper installation and operation to ensure reliable performance and compliance with regulatory standards.

Uploaded by

Jorge Luis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

D9859-Advanced-Receiver-Transcoder-SW-Version-1-10-Installation-and-Configuration-Guide

The document is an installation and configuration guide for the Cisco D9859 Advanced Receiver Transcoder Software Version 1.10, emphasizing the importance of reading the entire guide before use. It includes safety precautions, compliance information, and warranty disclaimers, highlighting the need to adhere to safety instructions to prevent hazards. Additionally, it provides guidelines for proper installation and operation to ensure reliable performance and compliance with regulatory standards.

Uploaded by

Jorge Luis
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 390

O L- 3198

0-01

Cisco D9859 Advanced Receiver


Transcoder Software Version 1.10
Installation and Configuration Guide
Please Read This Entire Guide
Veuillez lire entièrement ce guide
Bitte das gesamte Handbuch durchlesen
Sírvase leer completamente la prese nte guía

Si prega di leggere completamente questa guida

Important
Please read this entire guide before you install or operate this product. Give
particular attention to all safety statements.

Important
Veuillez lire entièrement ce guide avant d'installer ou d'utiliser ce produit. Prêtez
une attention particulière à toutes les règles de sécurité.

Zu beachten
Bitte lesen Sie vor Aufstellen oder Inbetriebnahme des Gerätes dieses Handbuch in
seiner Gesamtheit durch. Achten Sie dabei besonders auf die Sicherheit shinweise.

Importante
Sírvase leer la presente guía antes de instalar o emplear este producto. Preste
especial atención a todos los avisos de seguridad.

Importante
Prima di installare o usare questo prodotto si prega di leggere completamente questa
guida, facendo particolare attenzione a tutte le dichiarazioni di sicurezza.
Notices
THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN
THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL
STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL
ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT
WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL
RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.
THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE
ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION
PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED
HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE
SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO
REPRESENTATIVE FOR A COPY.
The following information is for FCC compliance of Class A devices: This equipment
has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio-
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications . Operation of this
equipment in a residential area is likely to cause harmful interference, in which case
users will be required to correct the interference at their own expense.

The following information is for FCC compliance of Class B devices: This equipment
has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If the equipment causes interference to radio or television
reception, which can be determined by turning the equipment off and on, users are
encouraged to try to correct the interference by using one or more of the following
measures:
Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

Modifications to this product not authorized by Cisco could void the FCC approval
and negate your authority to operate the product.
The Cisco implementation of TCP header compression is an adaptation of a program
developed by the University of California, Berkeley (UCB) as part of UCB’s public
domain version of the UNIX operating system. All rights reserved. Copyright ©
1981, Regents of the University of California.
NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT
FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED “AS IS” WITH
ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT
LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF
DEALING, USAGE, OR TRADE PRACTICE.
IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY
INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES,
INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE
TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL,
EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY
OF SUCH DAMAGES.

Cisco and the Cisco logo are trademarks or registered trademarks of Cisco and/or its
affiliates in the U.S. and other countries. To view a list of Cisco trademarks, go to this
URL: www.cisco.com/go/trademarks. Third-party trademarks mentioned are the
property of their respective owners. The use of the word partner does not imply a
partnership relationship between Cisco and any other company. (1110R)
Any Internet Protocol (IP) addresses and phone numbers used in this document are
not intended to be actual addresses and phone numbers. Any examples, command
display output, network topology diagrams, and other figures included in the
document are shown for illustrative purposes only. Any use of actual IP addresses
or phone numbers in illustrative content is unintentional and coincidental.

© 2014 Cisco Systems, Inc. All rights reserved.


AVC/MPEG-4/H.264 Products
With respect to each AVC/MPEG-4/H.264 product, Cisco is obligated to provide the
following notice:

THIS PRODUCT IS LICENSED UNDER THE AVC PATENT PORTFOLIO LICENSE


FOR THE PERSONAL AND NON-COMMERCIAL USE OF A CONSUMER TO (i)
ENCODE VIDEO IN COMPLIANCE WITH THE AVC STANDARD ("AVC VIDEO")
AND/OR (ii) DECODE AVC VIDEO THAT WAS ENCODED BY A CONSUMER
ENGAGED IN A PERSONAL AND NON-COMMERCIAL ACTIVITY AND/OR
WAS OBTAINED FROM A VIDEO PROVIDER LICENSED TO PROVIDE AVC
VIDEO. NO LICENSE IS GRANTED OR SHALL BE IMPLIED FOR ANY OTHER
USE. ADDITIONAL INFORMATION MAY BE OBTAINED FROM MPEG LA,
L.L.C. SEE HTTP://WWW.MPEGLA.COM.
Accordingly, please be advised that service providers, content providers and
broadcasters are required to obtain a separate use license from MPEG LA prior to
any use of AVC/MPEG-4/H.264 encoders and/or decoders.
Safety Precautions

Safety Precautions

1 Read Instructions – All the safety and operating instructions should be read
before the product is operated.
2 Retain Instructions – The safety and operating instructions should be reta ined for
future reference.
3 Heed Warnings – All warnings on the product and in the operating instructions
should be adhered to.
4 Follow Instructions – All operating and use instructions should be followed.
5 Cleaning – Unplug this product from the wall outlet before cleaning. Do not use
liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.
Exception: A product that is meant for uninterrupted service and that, for some
specific reason, such as the possibility of the loss of an authorization code f or a
CATV converter, is not intended to be unplugged by the user for cleaning or any
other purpose, may exclude the reference to unplugging the product in the
cleaning description above.
6 Attachments – Do not use attachments not recommended by the product
manufacturer as they may cause hazards.
7 Water and Moisture – Do not use this product near water – for example, near a
bath tub, wash bowl, kitchen sink, or laundry tub; in a wet basement; or near a
swimming pool; and the like.
Accessories – Do not place this product on an unstable cart, stand, tripod,
bracket, or table.
The product may fall, causing serious injury to a child or adult, and serious
damage to the product.

OL-31980 -01 vii


Safety Precautions

Use only with a cart, stand, tripod, bracket, or table recommended by the
manufacturer, or sold with the product. Any mounting of the product should
follow the manufacturer’s instructions, and should use a mounting accessory
recommended by the manufacturer.
8 A product and cart combination should be moved with care. Quick stops,
excessive force, and uneven surfaces may cause the product and cart
combination to overturn.

9 Ventilation – Slots and openings in the cabinet are provided for ventilation and
to ensure reliable operation of the product and to protect it from overheating,
and these openings must not be blocked or covered. The openings should never
be blocked by placing the product on a bed, sofa, rug, or other similar surface.
This product should not be placed in a built-in installation such as a bookcase or
rack unless proper ventilation is provided or the manufacturer’s instructions
have been adhered to.
10 Power Sources – This product should be operated only from the type of power
source indicated on the marking label. If you are not sure of the type of power
supply to your home, consult your product dealer or local power company. For
products intended to operate from battery power, or other sources, refer to the
operating instructions.
11 Grounding or Polarization – This product may be equipped with a polarized
alternating-current line plug (a plug having one blade wider than the other). This
plug will fit into the power outlet only one way. This is a safety feature. If you
are unable to insert the plug fully into the outlet, try reversing the plug. If the
plug should still fail to fit, contact your electrician to replace your obsolete outlet.
Do not defeat the safety purpose of the polarized plug. Alternate Warnings –
This product is equipped with a three-wire grounding-type plug, a plug having a
third (grounding) pin. This plug will only fit into a grounding-type power outlet.
This is a safety feature. If you are unable to insert the plug into the outlet, contact
your electrician to replace your obsolete outlet. Do not defeat the safety purpose
of the grounding-type plug.
12 Power-Cord Protection – Power-supply cords should be routed so that they are
not likely to be walked on or pinched by items placed upon or against them,
paying particular attention to cords at plugs, convenience receptacles, and the
point where they exit from the product.

viii OL-31980-01
Safety Precautions

13 Protective Attachment Plug – The product is equipped with an attachment plug


having overload protection. This is a safety feature. See Instruction Manual for
replacement or resetting of protective device. If replacement of the plug is
required, be sure the service technician has used a replacement plug specified by
the manufacturer that has the same overload protection as the original plug.
14 Outdoor Antenna Grounding – If an outside antenna or cable system is
connected to the product, be sure the antenna or cable system is grounded so as
to provide some protection against voltage surges and built -up static charges.
Article 810 of the National Electrical Code, ANSI/NFPA 70, provides
information with regard to proper grounding of the mast and supporting
structure, grounding of the lead-in wire to an antenna discharge unit, size of
grounding conductors, location of antenna-discharge unit, connection to
grounding electrodes, and requirements for the grounding electrode.

15 Lightning – For added protection for this product during a lightning storm, or
when it is left unattended and unused for long periods of time, unplug it from
the wall outlet and disconnect the antenna or cable system. This will prevent
damage to the product due to lightning and power-line surges.
16 Power Lines – An outside antenna system should not be located in the vicinity of
overhead power lines or other electric light or power circuits, or where it can fall
into such power lines or circuits. When installing an outside antenna system,
extreme care should be taken to keep from touching such power lines or circuits
as contact with them might be fatal.
17 Overloading – Do not overload wall outlets, extension cords, or integral
convenience receptacles as this can result in a risk of fire or electric shock.
18 Object and Liquid Entry – Never push objects of any kind into this product
through openings as they may touch dangerous voltage points or short -out parts
that could result in a fire or electric shock. Never spill liquid of any kind on the
product.

OL-31980 -01 ix
Safety Precautions

19 Servicing – Do not attempt to service this product yourself as opening or


removing covers may expose you to dangerous voltage or other hazards. Refer
all servicing to qualified service personnel.
20 Damage Requiring Service – Unplug this product from the wall outlet and refer
servicing to qualified service personnel under the following conditions:
a When the power-supply cord or plug is damaged,
b If liquid has been spilled, or objects have fallen into the product,
c If the product has been exposed to rain or water,
d If the product does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the operating
instructions as an improper adjustment of other controls may result in
damage and will often require extensive work by a qualified technician to
restore the product to its normal operation,
e If the product has been dropped or damaged in any way, and
f When the product exhibits a distinct change in performance – this indicates a
need for service.
21 Replacement Parts – When replacement parts are required, be sure the service
technician has used replacement parts specified by the manufacturer or have the
same characteristics as the original part. Unauthorized substitutions may result
in fire, electric shock, or other hazards.
22 Safety Check – Upon completion of any service or repairs to this product, ask the
service technician to perform safety checks to determine that the product is in
proper operating condition.
23 Wall or Ceiling Mounting – The product should be mounted to a wall or ceiling
only as recommended by the manufacturer.
24 Heat – The product should be situated away from heat sources such as radiators,
heat registers, stoves, or other products (including amplifiers) that produce heat.
Protect yourself from electric shock and your system from damage!

 This product complies with international safety and design standards. Observe
all safety procedures that appear throughout this guide, and the safety symbols
that are affixed to this product.
 If circumstances impair the safe operation of this product, stop operation and
secure this product against further operation.

Avoid personal injury and product damage! Do not proceed beyond any symbol
until you fully understand the indicated conditions!
You will find this symbol on the product and/or in the literature that
accompanies this product.
It indicates important operating or maintenance instructions.

x OL-31980-01
Safety Precautions

You may find this symbol on the product and/or in the literature that
accompanies this product.

It indicates a live terminal; the symbol pointing to the terminal device.


You may find this symbol on the product and/or in the literature that
accompanies this product.

It indicates a protective earth terminal.


You may find this symbol on the product and/or in the literature that
accompanies this product.

It indicates excessive or dangerous heat.

Power
 Important! This is a Class I product. You must earth this product. This
equipment may have up to two power supply cords. To reduce the risk of
electric shock, two power supply cords may have to be disconnected before
servicing.
 This product plugs into a socket-outlet. The socket-outlet must be near this
product, and must be easily accessible.
 Connect this product only to the power source that is indicated on the rear panel
of this product.

 If this product does not have a mains power switch, the power cord serves this
purpose

Enclosure
 Do not allow moisture to enter this product.

 Do not open the enclosure of this product unless otherwise specified.


 Do not push objects through openings in the enclosure of this product.

Cables
 Always disconnect all power cables before servicing this product.
 Always pull on the plug or the connector to disconnect a cable. Never pull on the
cable itself.
 Do not walk on or place stress on cables or plugs.

Factory service
 Refer service only to service personnel who are authorized by the factory.

OL-31980 -01 xi
Safety Precautions

Règles de sécurité
Protégez-vous des risques d'électrocution et protégez votre système contre les
endommagements éventuels.

Ce produit respecte les standards internationaux de sécurité et de conception.


Veuillez observer toutes les procédures de sécurité qui apparaissent dans ce guide,
ainsi que les symboles de sécurité qui figurent sur le produit.
Si, du fait des circonstances, ce produit cesse de fonctionner normalement, cessez de
l'utiliser et empêchez-en l'utilisation future.

Évitez le risque de blessures et de dommages aux produits! Ne procédez à aucune


tâche tant que vous n'aurez pas entièrement assimilé les conditions indiquées par un
symbole!
Ce symbole figure dans la documentation accompagnant ce produit. Il indique
d'importantes instructions de fonctionnement ou d'entretien.

Ce symbole peut être attaché à ce produit. Il indique une borne sous tension;
la direction indique la borne.

Ce symbole peut être attaché à ce produit. Il indique une borne de terre de


protection.

Ce symbole peut être attaché à ce produit. Il indique une température


excessive ou dangereuse.

Alimentation
 Important! Ce produit fait partie de la classe I. Vous devez le mettre à la terre.
 Ce produit se branche dans une prise murale. Cette dernière doit être placée à
proximité du produit et doit être facilement accessible.
 Ne branchez ce produit qu'à la source d'alimentation indiquée sur son panneau
arrière.

 Si ce produit n'a pas d'interrupteur d'alimentation générale, le cordon


d'alimentation remplit ce rôle.

Enceinte
 Ne laissez pas l'humidité pénétrer dans ce produit.

 N'ouvrez pas l'enceinte de ce produit, sauf instructions contraires.


 Ne forcez pas d'objets dans les ouvertures du boîtier.

Câbles
 Débranchez toujours tous les cordons d'alimentation avant de réparer ce produit.
 Tirez toujours sur la prise ou le connecteur pour débrancher un câble. Ne tirez
jamais directement sur le câble.

x ii OL-31980-01
Safety Precautions

 Ne marchez pas sur les câbles ou les prises et n'y exercez aucune pression.

Réparations effectuées à l'usine


 Ne confiez les travaux de réparations qu'au personnel autorisé par l'usine.

Sicherheitsvorkehrungen
Schützen Sie sich gegen elektrischen Schlag, und Ihr Gerät gegen Beschädigung!

 Dieses Gerät entspricht internationalen Sicherheits-und Ausführungsnormen.


Beachten Sie alle in diesem Handbuch enthaltenen Sicherheitshinweise sowie die
am Gerät angebrachten Warnzeichen.
 Sollten örtliche Umstände den sicheren Betrieb dieses Gerätes beeinträchtigen,
schalten Sie es ab und sichern es gegen weitere Benutzung.

Vermeiden Sie Verletzungen sowie Beschädigung des Gerätes! Wenn Sie zu einem
der folgenden Warnzeichen gelangen, nicht weiterarbeiten, bis Sie seine Bedeutung
voll verstanden haben!
Dieses Symbol erscheint auf dem Gerät und/oder in der ihm beiliegenden
Literatur. Es bedeutet wichtige, zu beachtende Betriebs-oder
Wartungsanweisungen.

Wenn dieses Zeichen am Gerät angebracht ist, warnt es vor einer


spannungsführenden Stelle.
Dieses Symbol kennzeichnet auf dem Gerät die Anschlußstelle der
Sicherheitserde.
Wenn dieses Zeichen am Gerät angebracht ist, warnt es vor heißen Stellen, die
zu Verbrennungen führen können.

Netzspannung
 Wichtig! Dieses Gerät ist ein Produkt der Schutzklasse I. Es muß geerdet werden.

 Das Gerät ist an einer Steckdose anzuschließen. Diese muß sich leicht zugänglich
in unmittelbarer Nähe des Gerätes befinden.
 Die Netzversorgung muß den auf der Rückwand des Gerätes angegebenen
Werten entsprechen.
 Falls sich kein Hauptschalter am Gerät befindet, dient das Netzkabel diesem
Zweck.

Gehäuse
 Das Innere des Gerätes ist vor Feuchtigkeit zu schützen.
 Das Gehäuse ist nicht zu öffnen.

 Niemals einen Gegenstand durch die Gehäuseöffnungen einführen!

OL-31980 -01 x iii


Safety Precautions

Kabel
 Vor jeglicher Wartung des Gerätes sind alle Kabel zu entfernen.

 Hierzu grundsätzlich am Stecker oder Verbindungsstück und niemals am Kabel


selber ziehen.
 Nicht auf die Kabel oder Stecker treten oder diese einer Zugbelastung aussetzen.

Hersteller-Wartung
 Wartungsarbeiten sind nur durch vom Hersteller autorisierte Techniker
vorzunehmen.

Precauciones de seguridad
¡Protéjase contra la electrocución y proteja su sistema contra los daños!

Este producto cumple con los criterios internacionales de seguridad y diseño.


Observe todas los procedimientos de seguridad que aparecen en esta guía, y los
símbolos de seguridad adheridos a este producto.
Si las circunstancias impiden la operación segura de este producto, suspenda la
operación y asegure este producto para que no siga funcionando.

¡Evite lastimarse y evite dañar el producto! No avance más allá de cualquier símbolo
hasta comprender completamente las condiciones indicadas!
Encontrará este símbolo en el impreso que acompaña a este producto. Este símbolo
indica instrucciones importantes de funcionamiento o mantenimiento.

Es posible que este símbolo esté pegado al producto. Este símbolo indica un
terminal vivo, la flecha apunta hacia el aparato terminal.

Podría encontrar este símbolo pegado al producto. Este símbolo indica un terminal
de protección de tierra.

Podría encontrar este símbolo pegado al producto. Este símbolo indica calor
excesivo o peligroso.

Alimentación
 Importante! Este es un producto de Clase I. Tiene que estar conectado a tierra.

 Este producto se conecta a un enchufe. El enchufe necesita estar cerca del


producto y ser fácilmente accesible.

 Conecte este producto únicamente a la fuente de suministro eléctrico indicada en


el panel posterior del producto.

 Si el producto no tiene interruptor para la linea principal, utilice el cordón to ma


de corriente para este propósito.

x iv OL-31980-01
Safety Precautions

Cubierta
 No permita que la humedad penetre en este producto.

 No abra la cubierta del producto a menos que se indique lo contrario.


 No introduzca objetos a través de las aberturas de la cubierta del producto.

Cables
 Siempre desconectar todos los cables eléctricos antes de revisar o reparar el
producto.
 Tire siempre del enchufe o del conector para desconectar un cable. Nunca tire del
cable mismo.
 No camine ni aplique presión sobre los cables o enchufes..

Revisión y reparación de fábrica


 Solo personal aprobado por la fábrica puede darle servicio al producto.

Precauzioni di sicurezza
Proteggetevi da scosse elettriche e proteggete il vostro sistema da possibili danni!
 Questo prodotto soddisfa le norme internazionali per la sicurezza ed il design.
Seguite tutte le procedure di sicurezza contenute in questa guida e i simboli di
sicurezza applicati al prodotto.
 Se circostanze avverse compromettono la sicurezza d'uso di questo prodotto,
interrompetene l'uso e assicuratevi che il prodotto non venga più utilizzato.
Evitare infortuni alla persona e danni al prodotto! Non procedere oltre a qualunque
simbolo fino a quando non si siano comprese pienamente le condizioni indicate!
Questo simbolo, che appare nella letteratura di accompagna mento del
prodotto, indica importanti istruzioni d'uso e di manutenzione.

Sul prodotto potete vedere questo simbolo che indica un dispositivo terminale
sotto tensione; la freccia punta verso il dispositivo.

Potrete trovare il presente simbolo applicato a questo prodotto. Questo


simbolo indica un terminale protettivo di messa a terra.

Potrete trovare il presente simbolo attaccato a questo prodotto. Questo


simbolo indica un calore eccessivo o pericoloso.

Alimentazione
 Importante! Questo prodotto è di Classe I. Va messo a terra.
 Questo prodotto si inserisce in una presa di corrente. La presa di corrente deve
essere in prossimità del prodotto, e deve essere facilmente accessibile.

OL-31980 -01 xv
Safety Precautions

 Collegare questo prodotto solamente alla fonte di alimentazione indicat a sul


pannello posteriore di questo prodotto.
 Se questo prodotto non è dotato di un interruttore principale, il cavo di
alimentazione funge a questo scopo.

Chiusura
 Proteggete da umidità questo prodotto.
 Non aprire la chiusura di questo prodotto a meno che non sia specificato
diversamente. Non inserire oggetti attraverso le fessure della chiusura.

Cavi
 Staccare sempre tutti i cavi di alimentazione prima di svolgere l'assistenza
tecnica al prodotto.

 Per scollegare un cavo tirate la spina o il connettore, non tirare mai il cavo stesso.
 Non calpestare o sottoporre a sollecitazioni i cavi o le prese.

Riparazionoi di fabbrica
 Per le riparazioni contattate solamente personale tecnico autoizzato dalla
fabbrica.

x vi OL-31980-01
Contents

Safety Precautions vii

About This Manual xxiii


Objective............................................................................................................. xxiii
Audience ............................................................................................................ xxiii
Required Knowled ge......................................................................................... xxiii

Chapter 1 Introduction 1
D9859 Advanced Receiver T ranscod er .............................................................................. 2
Digital Program Distribution................................................................................. 2
Key Features ............................................................................................................ 2
Software Update ..................................................................................................... 3
Transport Stream Outputs.................................................................................................. 4
DVB-ASI Outputs ................................................................................................... 4
MPEGoIP Output ................................................................................................... 4
MPE Output ............................................................................................................ 5
Disaster Recovery ................................................................................................................ 6

Chapter 2 Quick Setup - Read Me First! 9


Maintena nce of EMC Comp liance ................................................................................... 10
Connecting t he T ranscod er to Other Equ ipment ............................................................ 11
Setting up for Net work Connection................................................................................. 12
Quick Setup Instructions for RF Acqu isition .................................................................. 13
Assigning a Program C hannel to a PE (Program E ntry) ................................................ 15
Setting up the ASI Output ................................................................................................ 16
Setting t he DP M Mod e...................................................................................................... 17

Chapter 3 Installation 19
Power Connection ............................................................................................................. 20
Installing the D9859 Transcoder ....................................................................................... 21
Rack Mount ed ....................................................................................................... 21
Cooling .................................................................................................................. 21
Grounding ............................................................................................................. 21
Mou nting the D9859 Transcoder to a Rack ......................................................... 21
Connecting t he AC Power to the D9859 Transcoder ......................................... 22
Rear C onnector Panel........................................................................................................ 23
Connecting t he I nput/Output Signals............................................................................. 25
Connecting t he RF Inputs .................................................................................... 25
Connecting t he ASI Input .................................................................................... 25
Connecting t he Video Outputs ............................................................................ 25
Connecting t he Balanced Audio Output............................................................. 25
Connecting t he Ethernet Managem ent Int erface ................................................ 26
Connecting t he IP TS Output............................................................................... 26
Connecting t he ASI Outputs................................................................................ 27
Connecting a n External Alarm S ystem ............................................................... 27
Connecting t he RS-232 Data Interface................................................................. 28
Connecting t he Cue T one/Cue T rigger Interface .............................................. 28
Configuring Op en-collector Outputs .................................................................. 29
Setting Adm in User Privileges via a Telnet/SSH Connection ....................................... 30
Administrator User P rivileges ............................................................................. 30
Starting a Telnet/SSH Session ............................................................................. 30
Adding a New User.............................................................................................. 31
Deleting a User...................................................................................................... 31
Changing a Username .......................................................................................... 32
Changing a Password (allowed by all Users) ..................................................... 32
Print ing the List of Users...................................................................................... 32
Resetting t he Login Credentials .......................................................................... 32

Chapter 4 Front Panel Operation 33


About the Front Panel ....................................................................................................... 34
LCD........................................................................................................................ 34
Keypad .................................................................................................................. 34
Front Panel LEDs .................................................................................................. 34
Navigation/S elect ion Keypad ............................................................................. 35
Locking/U nlocking the Front Panel ................................................................................ 38
Startup Screen.................................................................................................................... 39
Main Structure ...................................................................................................... 39
Channel Authorization Status ............................................................................. 39
LCD Panel ............................................................................................................. 39
LCD Symbol .......................................................................................................... 40
Assigning P rogram to the P rogram Entry .......................................................... 41
Deleting a Program from the P rogram Ent ry ..................................................... 42
Main Menu ......................................................................................................................... 43
Status Menu ....................................................................................................................... 44
Structure ................................................................................................................ 44
Status Menu - IP.................................................................................................... 52
Status Menu - DR.................................................................................................. 53
Setup Menu ........................................................................................................................ 56
Setup Menu: Admin ............................................................................................. 57
Setup Menu: TS Input........................................................................................... 62
Setup Menu: IP...................................................................................................... 68

x viii OL-31980-01
Setup Menu: Services ........................................................................................... 76
Setup Menu: Outputs ........................................................................................... 88
Setup Menu: CA ................................................................................................. 115
Setup Menu: Alarm/Wa rning ........................................................................... 117
Setup Menu: Noise Cutoffs ................................................................................ 119
Setup Menu: DR.................................................................................................. 121
About Menu ..................................................................................................................... 124
General ................................................................................................................ 124
Licenses ............................................................................................................... 125
Versions Menu ................................................................................................................. 126
Main Versions ..................................................................................................... 126
Transcod er Softwa re Versions ........................................................................... 128
Transcod er Hardwa re Versions ......................................................................... 128
Diagnostics Menu ............................................................................................................ 129
Alarms/Warnings .............................................................................................. 129
Logs...................................................................................................................... 129
PSI - Frequ ency Plan........................................................................................... 130
PSI - Channels ..................................................................................................... 130
PSI - Tables .......................................................................................................... 131
Power On............................................................................................................. 131
Health Monitor ................................................................................................... 132

Chapter 5 Web GUI Setup and Monitoring 133


Logging O n to the Web GUI ........................................................................................... 134
D9859 Summary Overview ............................................................................................ 135
Shortcuts .............................................................................................................. 135
Modules ............................................................................................................... 136
Alarms/Warnings .............................................................................................. 137
D9859 Menus ................................................................................................................... 138
D9859 Web GUI Environm ent ........................................................................................ 140
Wind ow Buttons ................................................................................................. 140
Setting up Input Information ......................................................................................... 141
Setting up the RF Input ...................................................................................... 141
Setting up the ASI Input..................................................................................... 146
Setting up SI Receive Parameters ...................................................................... 148
Setting up Muting Thres hold C ontrols ............................................................. 151
Viewing the Input Status.................................................................................... 153
Configuring t he Disaster Recovery Settings ..................................................... 154
Viewing the Disaster Recovery Status .............................................................. 157
Setting up the Cha nnel S elections ..................................................................... 159
Viewing the Cha nnel Status............................................................................... 160
Viewing the CA Status ....................................................................................... 162
Setting up the BISS Mod e................................................................................... 163
Viewing the PSI Tables ....................................................................................... 164
Viewing PSI Frequ ency Information................................................................. 165
Viewing the PSI Channels .................................................................................. 166
Viewing the PID Input Status ............................................................................ 167
Setting up Audio and Video Information ...................................................................... 168
Setting up the Vid eo Parameters ....................................................................... 168
Setting up Captions ............................................................................................ 170
Setting up Subtitles ............................................................................................. 171
Setting up VBI ..................................................................................................... 173
Setting up Audio Param eters ............................................................................. 174
Setting up Cueing Parameters ........................................................................... 177
Setting up Cue Tone Test ................................................................................... 179
Setting up Cue Tones.......................................................................................... 180
Setting up Services .............................................................................................. 181
Configuring T ransport Stream Information .................................................................. 182
Configuring t he ASI Output .............................................................................. 182
Configuring t he DP M ASI Details ..................................................................... 188
Viewing the ASI Output Transport Status........................................................ 194
Configuring t he MPEGoIP Output.................................................................... 195
Configuring t he DP M MPE GoIP Output Details ............................................. 203
Viewing the MPE G Output Transport Status................................................... 210
Typical set up for Digital Program Mapping (DPM) ....................................... 210
Setting up Default Settings for the Tra nscoder ................................................ 213
Configuring S ystem Settings .......................................................................................... 218
Viewing the System Identification .................................................................... 218
Viewing Ha rdware Features and Base Licens e Information ........................... 219
Setting up IP Information................................................................................... 220
Setting up IP Routing I nformation .................................................................... 224
Configuring t he MPE Settings ........................................................................... 226
Setting up SNMP I nformation and T rap Destinations .................................... 228
Configuring T ime/C lock S ettings ..................................................................... 230
Viewing the Alarm/ Warning Status................................................................. 231
Setting up Alarms a nd Warnings ...................................................................... 232
Viewing Alarm/ Warning History .................................................................... 235
Viewing Version I nformation ............................................................................ 236
Viewing Tra nscoder Version I nformation ........................................................ 239
Setting up Import/Export File Information ..................................................... 241
Setting up Import/Export FTP Information ..................................................... 243
Managing D9859 Web GUI Accou nts ............................................................... 245
Configuring Lock Level Settings ....................................................................... 249
Configuring Front Panel Settings ...................................................................... 251
Viewing Support Inf ormation ........................................................................................ 252
Viewing Contact Information ............................................................................ 252
Viewing Diagnostic Logs ................................................................................... 253
Viewing the Usage Cou nters ............................................................................. 254
Viewing Operating Fan Speeds and Board T emperatures .............................. 255
Viewing Alarm/ Warning History .................................................................... 256
Loading a Software Version and L icense .......................................................... 257

xx OL-31980-01
Chapter 6 Service and Maintenance 259
D9859 Transcoder Alarm Messages ............................................................................... 260
Alarms ................................................................................................................. 260
Warnings ............................................................................................................. 299
Power Supply Replacement............................................................................................ 317

Chapter 7 Customer Information 319

Appendix A Technical Specifications 321


L-Band Input and Process ing ......................................................................................... 322
General ................................................................................................................ 322
LNB LO Stability................................................................................................. 322
LNB Power and C ontrol..................................................................................... 323
DVB-S/DVB-S2................................................................................................... 323
Video I nputs/Outputs and Processing .......................................................................... 326
General ................................................................................................................ 326
Video I nputs........................................................................................................ 326
Video Outputs..................................................................................................... 326
Audio Inputs/Outputs....................................................................................... 329
VBI Data Input/Output ..................................................................................... 330
Transport Stream Outputs.............................................................................................. 331
ASI Output .......................................................................................................... 331
MPEGoIP Output ............................................................................................... 331
MPE Output ........................................................................................................ 331
Control, Ma nagement and Data Interfaces ................................................................... 333
Ethernet Managem ent Int erface ........................................................................ 333
Ethernet Data Interface....................................................................................... 333
RS-232 Data Interface ......................................................................................... 333
Alarm Interface ................................................................................................... 333
Contact Closure Interface ................................................................................... 334
Power and General Specif ications .................................................................................. 335
General ................................................................................................................ 335
Power................................................................................................................... 335
Mechanical .......................................................................................................... 336
Environment ....................................................................................................... 336

Appendix B Default Settings and Lock Levels 337


Factory Default Settings and Lock Levels ..................................................................... 338
Administration.................................................................................................... 338
ASI Input ............................................................................................................. 339
RF Input ............................................................................................................... 339
Tune Mode .......................................................................................................... 340
Disaster Recovery ............................................................................................... 340
IP .......................................................................................................................... 341
Trap Destinations ............................................................................................... 342
Protocols .............................................................................................................. 342
Video.................................................................................................................... 342
Audio ................................................................................................................... 343
Captions .............................................................................................................. 343
VBI ....................................................................................................................... 343
Subtitles ............................................................................................................... 343
Decode ................................................................................................................. 344
Cueing ................................................................................................................. 344
TS Out - ASI ........................................................................................................ 345
TS Out - MOIP .................................................................................................... 345
DPM - ASI/MOIP ............................................................................................... 346
Transcod e ............................................................................................................ 347
Inband .................................................................................................................. 348
Options ................................................................................................................ 348
Alarm/Warning.................................................................................................. 349
Noise Cutoff ........................................................................................................ 349
Import/Export (Web GUI only) ........................................................................ 350
DPM Default Settings for Different Output Modes ...................................................... 351

Appendix C Compliance 355


Applicable Standa rds and Notices ................................................................................. 356
Safety ................................................................................................................... 356
ESD ...................................................................................................................... 356
Electromagnetic Compatibility Regulatory Requirem ents .............................. 356
FCC Notices ........................................................................................................ 357
Industry Canada Notice ..................................................................................... 357
Unauthorized Modifications .............................................................................. 357
Declaration of Conform ity .............................................................................................. 358

Index 361

xxii OL-31980-01
About This Manual

About This Manual


Objective
This manual describes how to install, use and maintain the Cisco D9859 Advanced
Receiver Transcoder.
Note: The manual describes all available options for the D9859 transcoder. Your
D9859 transcoder may only have some of the features described in this manual.

Audience
The audience of this manual includes users (operators) and service personnel who
are responsible for the installation, configuration, operation, monitoring and service
of the D9859 transcoder.

Required Knowledge
To use this documentation, the user should have a basic knowledge of the
technology used in relation to this product. Service personnel should have
additional skills and be familiar with cabling, electronic circuitry, and wiring
practices.

This manual is intended for operators who are responsible for the configuration,
remote operation and maintenance of the D9859 transcoder.

OL-31980 -01 x x iii


1 Chapter 1
Introduction
Overview
This chapter is a general introduction to the Cisco D985 9 Advanced
Receiver Transcoder. It describes the most common applications and
interfaces of the transcoder.

In This Chapter
 D9859 Advanced Receiver T ranscod er ...............................................2
 Transport Stream Outputs...................................................................4
 Disaster Recovery.................................................................................6

OL-31980 -01 1
Chapter 1 Introduction

D9859 Advanced Receiver Transcoder


The Cisco D9859 Advanced Receiver Transcoder extends the distribution op tions for
MPEG-4 Advanced Video Coding (AVC) high definition from solely MPEG-4
environments to existing MPEG-2 networks. Support for up to eight simultaneous
high-definition or standard-definition (SD) channels of decryption and transcoding
provides the advantage of density for locations requiring more than just a single
channel. The D9859 can provide up to 8 down-converted MPEG-2 standard
definition programs or MPEG-2 high-definition transcoded programs. Video and
two audio outputs are available for analog down-conversion for one of the
decrypted incoming MPEG-4 high-definition programs.

Digital Program Distribution


The Asynchronous Serial Interface (ASI) and MPEG over IP (MPEGoIP) transport
outputs are individually configurable and provide the capability of carrying up to
eight decrypted transcoded programs for digital tier distribution. This helps the
compressed video programs to be efficiently distributed to subscribers equipped
with digital set-top boxes. Digital audio passthrough is synchronized to the
transcoded program output. Compliant program-specific information and service
information (PSI/SI) regeneration provides integration into a digital tier distribution
network for eight transcoded programs.

Key Features
The D9859 Advanced Receiver Transcoder provides the following key features:

 Four L-Band inputs

 DVB-S Demodulation for QPSK


 DVB-S2 Demodulation for QPSK and 8PSK

 Cisco PowerVu ® conditional access with Data Encryption Standard (DES) or DVB
descrambling
 Supports Basic Interoperable Scrambling System (BISS) conditional access

 Decryption and transcoding of up to eight programs for digital transport output

 Two digital transport outputs available (ASI and MPEGoIP)


 Support for up to eight simultaneous high-definition or standard-definition
channels of decryption and transcoding and passthrough of the original channel.
Total of 16 regenerated outputs (8 transcode + 8 passthrough)
 Program transcoding to support down-conversion of a MPEG-4 HD program to
a MPEG-2 SD program

2 OL-31980-01
D9859 Advanced Receiver Transcoder

 PSI/SI regeneration support on all licensed outputs (up to eight programs


transcoded + up to 8 original content pass through)
 4:2:0 high-definition 1080i and 720p video decoding

 AFD support for down-conversion of a decoded HD program with aspect ratio


conversion

 Dolby Digital (AC-3) and Dolby Digital Plus (E-AC-3) audio decoding
 Closed captioning passthrough of EIA-608 and EIA-708 for transcoded programs

 Audio passthrough synchronization for transcoded programs

 Additional ASI outputs for redundancy

 MPEGoIP output for network connectivity


 DVB subtitle passthrough with transcode programs

 Contact closure terminals for simple alarm monitoring

 Simple Network Management Protocol (SNMP) for setup, control, and


monitoring
 Field-upgradeable software

 Field-upgradable additional transcoder channel licenses

 Front panel LCD for control and monitoring


 Web browser interface for easy setup, control, and monitoring

 Uplink addressable decoder output control (vertical blanking interval [VBI],


audio routing, DPI, and ASI output)
 Dual-tone multifrequency (DTMF) cue tone and cue trigger outputs for ad
insertion
 Digital Program Mapping that provides uplink control for service replacements
in blackout areas
 Advanced Disaster Recovery capabilities

Software Update
All software in the D9859 transcoder is stored in non-volatile memory that can be
electrically programmed. New software releases for the D9859 transcoder can be
downloaded via the Ethernet 10/100/1000BASE-T Management interface.

OL-31980 -01 3
Chapter 1 Introduction

Transport Stream Outputs


DVB-ASI Outputs
The D9859 transcoder has three DVB-ASI outputs. These outputs can be used as
inputs for multiplexers, groomers or other types of DVB-ASI reception equipment.

MPEGoIP Output
The MPEGoIP output provides a number of output modes including the capability
of carrying a decrypted program for digital tier distribution. This helps ensure that
compressed video programs are efficiently distributed to households equipped with
digital set-top boxes. Digital Program Insertion (DPI) information will also be
available along with the video and audio PIDs (Packet Identifiers) for external ad -
insertion in compressed digital format.
The diagram below shows an example of the D9859 transcoder used in an ASI or
MPEGoIP application.

4 OL-31980-01
Transport Stream Outputs

MPE Output
The Multiprotocol Encapsulation (MPE) output provides a means to carry packet
oriented IP protocols on top of a transport stream. The MPE output receives IP
packets from the transport stream and the IP data can be sent through an Ethernet
switch to an IP router or directly to a receiving device.

The diagram below shows an example of the D9859 transcoder used in an MPE
application.

OL-31980 -01 5
Chapter 1 Introduction

Disaster Recovery
In the event of a transmission failure on the primary feed, the disaster recovery
allows for continued programming, with limited to no downtime. The failure
condition could be triggered by one of the following events:

 RF Lock Loss
 Unstable RF signal

 Transport Loss (RF locked, but no transport stream packets and NULL packets
received)

Once the receiver detects a failure after the configured timeout, it will initiate a
disaster recovery search based on the search path determined by the disaster
recovery configuration. A DR symbol is displayed on the front panel, and the D9859
web GUI displays a D/R in progress status. During a disaster, the receiver will
attempt to tune to a different backup transport, based on the search path configured.
The origin transport consists of origin transport tuning parameters and PE service
IDs, configured in the Input menus. For more information on the Input parameters,
see RF1, RF2, RF3, RF4 (RFx) Input (on page 63) for the front panel, and Setting up
the RF Input (on page 141) for the web GUI.
Note: If you perform a master PE channel change during a disaster recovery search,
the search will end, the current tuning parameters will be locked, and the current
channel will become the origin channel. If you perform a tuning change during a
disaster recovery search, the search will end, the current user tuning parameters will
become the origin tuning parameters, and the origin may be updated by any of the
NIT updates that follow.

For example, the disaster recovery is configured as follows:

Program Origin Transport Backup 1 Backup 2 Backup 3


Entry Channel Number Transport Transport Transport
Channel Channel Channel
Number Number Number

PE1 101 11 101 801

PE2 2 12 1005

When disaster occurs, the receiver will tune to channel 11, as defined on the Backup
1 transport.
If the acquisition is successful on the Backup 1 transport (PAT is received), the
receiver will set PE 1 to channel 11 and PE2 to channel 12 and declare t hat the
disaster is over.

6 OL-31980-01
Disaster Recovery

If the acquisition fails or there is no signal lock on the Backup 1 transport, the
receiver will continue to search for the next backup transport for PE1 (Backup 2
transport). If the acquisition is successful on the Backup 2 transport, the receiver will
set PE1 to channel 101, but leave PE2 to channel 2 because PE2 is not specified for
Backup 2 transport.
If the acquisition fails or there is no signal lock on the Backup 2 transport, it will
continue the search path and set PE1 to channel 801 and PE2 to channel 1005 if the
acquisition is successful on the Backup 3 transport. However, if the acquisition fails
or there is no signal lock on the Backup 3 transport, the search path will continue to
the origin transport. The search path will cycle through origin, Backup 1, Backup 2,
and Backup 3 infinitely.

The search path is shown in the Disaster Recovery Status information on the front
panel and web GUI.
By default, the disaster recovery is enabled. To set up and view the disaster recovery
parameters using the front panel, see Setup Menu: DR (on page 121) and Status
Menu - DR (on page 53). To set up and view the disaster recovery parameters using
the web GUI, see Configuring the Disaster Recovery Settings (on page 154) and
Viewing the Disaster Recovery Status (on page 157).

OL-31 980 -01 7


2 Chapter 2
Quick Setup - Read Me First!
Overview
This chapter provides a quick setup for the Cisco D9859 Advanced
Receiver Transcoder. If you are unsure about which receiver settings
to use, contact your local service provider for assistance.

In This Chapter
 Maintena nce of EMC Comp liance ....................................................10
 Connecting t he T ranscod er to Other Equ ipment .............................11
 Setting up for Net work Connection..................................................12
 Quick Setup Instructions for RF Acqu isition ...................................13
 Assigning a Program C hannel to a PE (Program E ntry) .................15
 Setting up the ASI Output .................................................................16
 Setting t he DP M Mod e.......................................................................17

OL-31980 -01 9
Chapter 2 Quick Setup - Read Me First!

Maintenance of EMC Compliance


Double-shielded (braid/foil or braid/braid) cables should be used for all ASI I/O
and RF inputs. Single-shield cables are acceptable for all other inputs and outputs.
For terminal block (Alarms) I/O, no shielding is required.

10 OL-31980-01
Connecting the Transcoder to Other Equipment

Connecting the Transcoder to Other Equipment


The following displays the rear panel of the D9859 transcoder:

1 Connect the L-Band signal to RF1. 13V or 18V LNB power is only available on
the RF1 port. The factory default setting for LNB power is OFF.
2 Connect the ASI OUT port to an ASI device for digital tier applications.
Note: A double-shielded coaxial cable is required to connect to the ASI OUT
and/or the ASI IN port in order to meet EMC requirements.
3 Connect the Composite Video Outputs to a video monitor.
4 Using a multi-conductor, pluggable cable, connect the balanced audio outputs,
terminal blocks AUDIO 1 and AUDIO 2 to monitoring equipment.
5 Apply power by connecting the transcoder to a power outlet. The message
“Application Starting” will appear on the front panel. The boot -up process will
take approximately 1 minute for the unit to initialize. When ready, the front
panel display shows the start-up screen.
The power cord (consisting of appliance coupler, flexible cord, and plug)
supplied with this product meets the requirements for use in the country for
which this product was purchased. In general, the power cord must be approved
by an acceptable, accredited agency responsible for evaluation in the country
where the product will be used.

OL-31980 -01 11
Chapter 2 Quick Setup - Read Me First!

Setting up for Network Connection


1 Press MENU to display the Main menu.
2 If the Advanced Receiver Transcoder is to be connected to a network, press to
move to the Setup menu. Press SELECT. Press twice to select the IP menu.
Press SELECT twice to go to the IP menu.
3 Use the arrow keys to navigate up and down the IP menu, and the arrow
keys to move across the IP menu to set the IP Address, Mask and Gateway
parameters. Use the number keys to directly enter numbers in the fields. For
more information on keypad operation, see Keypad (on page 34).
4 Press SELECT each time to save the changes. Press MENU four times to return
to the startup screen.

12 OL-31980-01
Quick Setup Instructions for RF Acquisition

Quick Setup Instructions for RF Acquisition


1 Press MENU to display the Main menu.
2 Press to go to the Setup menu. Press SELECT. Press to move to the TS Input
menu. Press SELECT.
3 To setup the ASI input port, go to step 4. To setup the RF1 input port, go to step
5.
4 Press SELECT three times. Press to set the ASI port to Act (Activate). Press
SELECT. Go to step 11.
5 Press SELECT. Press to go to RF1. Press SELECT twice. Use to set the RF1
port parameter to Act (Activate). Press SELECT.
6 Press to move to the LO1, LO2, Crossover menu. Verify these parameters for
your application. If no change is needed, go to Step 7. If required, you may
modify these settings. Use to move to the parameter that you want to modify.
Press SELECT. Use the numerical keypad to enter new frequencies. Press
SELECT.
7 Press five times to move to the Modulation and Rolloff menu. Press SELECT.
Use to choose DVB-S or DVB-S2. Press SELECT. If DVB-S2 is used, press to
choose Rolloff. Press SELECT. Use to choose the value. Press SELECT.
8 Press to move to the Freq., Sym Rate, and FEC menu. Press SELECT. Enter the
RF frequency. Press SELECT. Press to move to the Sym. Rate menu. Press
SELECT. Enter the symbol rate. Press SELECT. If DVB-S2 is used, proceed to
step 9. If DVB-S is used, press to set up the FEC. Press SELECT. Use to
select AUTO. Press SELECT.
9 Press twice to move to the Net ID menu. Press to choose Net ID. Press
SELECT. Enter the value. Press SELECT.
10 Press . Press SELECT. Use to change the LNB power, if needed. Only the
RF1 port is capable of providing 13V or 18V. Press SELECT.
11 Press MENU three times. Press to move to Save & Exit. Press SELECT. Save &
Exit will return you to the Main: Setup menu; Abandon & Exit will go back to the
last menu accessed with the original parameters; Cancel will go back to the last
menu accessed with changes saved.
12 The transcoder will search for the signal and display “Acquisition Successful." It
will find the first available channel on the network. Press MENU twice to return
to the start-up menu.

OL-31980 -01 13
Chapter 2 Quick Setup - Read Me First!

13 If the front LED is solid green, the unit is authorized. Proceed with Assigning a
Program Channel to a PE (Program Entry) (on page 15)). If the front LED is
flashing green, the unit is unauthorized. Please contact your service provider and
provide the Tracking ID number for authorization. The Tracking ID can be found
on the ABOUT menu. To locate the Tracking ID, press MENU, press twice, and
then press SELECT twice. Make a note of the Tracking ID number. Press MENU
three times to return to the startup screen.

14 OL-31980-01
Assigning a Program Channel to a PE (Program Entry)

Assigning a Program Channel to a PE (Program


Entry)
1 At the start-up screen, PE1 is initially displayed.
PE Ch #

PE1 1 Channel Name s

RF1 Freq:12.658 Lvl:<-50 Marg:11.6

2 Press ADV and use the keys to scroll through the available program entries.
Note: The D9859 is available in an eight channel configuration.
3 Press ADV again to select the channel number.
4 Use the keys to scroll through the available program channels or directly
enter the channel number using the 0 to 9 keys; press SELECT to save the
channel selection.
Note: Enter 0 to remove the program channel from the Program Entry.
5 Repeat steps 2 to 4 to select another authorized program to decode.

OL-31980 -01 15
Chapter 2 Quick Setup - Read Me First!

Setting up the ASI Output


1 Press MENU to move to the Main Menu.
2 Press to move to the Setup menu. Press SELECT.
3 Press to move to the Outputs menu. Press SELECT.
4 Press to move to the TS Out menu. Press SELECT.
5 Press SELECT to access the ASI menu. Press . Press SELECT. Use to select
the output mode. The factory default is "No Output". It is recommended to set
the Output Mode to Transcoding.
6 Press SELECT. Press to select "YES" if requested to "RESYNC ALL?". Press
SELECT.
7 Press to move to Descramble Mode menu. Press SELECT. Use to select the
scrambling mode. Press SELECT.
8 Press to move to Insert Null Packet. Press SELECT. Use to change the
mode to Yes. Press SELECT.
9 Press APPLY. Press SELECT.
10 Press MENU five times to return to the startup menu.

16 OL-31980-01
Setting the DPM Mode

Setting the DPM Mode


A program can be set to one of four Digital Program Mapping (DPM) modes, either
Drop, Pass, Map, or Xcode. For more information, see TS Out - DPM (on page 99).

LCD Setting Description

Drop Removes the service and its associated PMT reference


from the transport output.
Pass Permits the source content and PMT reference to appear
in the transport output with the same references unless
the source material is mapped on another PE.

Map Provides the flexibility to define all the outgoing PID


numbers for a PE, including those not currently on
transmission.

Xcode Provides the flexibility to define all the outgoing PID


numbers for a PE, including those not currently on
transmission, as in Map mode, plus the video PID is
transcoded to output at the rate and settings defined for
the transcode channel.
1 Press MENU to display the Main Menu.
2 Press to move to the Setup menu. Press SELECT.
3 Press four times to move to the Outputs menu. Press SELECT.
4 Press to move to the TS Out menu. Press SELECT.
5 Press twice to move to the DPM menu. Press SELECT.
6 Press SELECT to access the Global menu.
7 Press SELECT to choose ASI for Resync All. Press and then press SELECT to
continue.
8 Press MENU. Press to move to the ASI menu. Press SELECT. Verify the PE1
”InCh” and ”OutCh” programs.
9 Press three times to choose Act. Press SELECT. Use to select the DPM
mode. Xcode (Transcode) is the most common mode. Press SELECT. Press
APPLY. Press SELECT to save the changes.
10 Press three times to choose PE1. Press SELECT. Use to select PE2. Press
SELECT. Verify the PE2 “InCh” and “OutCh” programs.
11 Press three times to choose Act. Press SELECT. Use to select the DPM
mode. Xcode (Transcode) is the most common mode. Press SELECT. Press
APPLY.
12 Press MENU six times to return to the startup screen.

OL-31980 -01 17
3 Chapter 3
Installation
Introduction
This chapter contains the information for technicians installing the
Cisco D9859 Advanced Receiver Transcoder.

Qualified Personnel
Only appropriately qualified and trained service personnel should
attempt to install, operate, or maintain the D9859 transcoder.
WARNING:
Allow only authorized and qualified service personnel to install,
operate, maintain, and service this product. Otherwise, personal
injury or equipment damage may occur.

In This Chapter
 Power Connection ..............................................................................20
 Installing the D9859 Transcoder........................................................21
 Rear C onnector Panel.........................................................................23
 Connecting t he I nput/Output Signals..............................................25
 Setting Adm in User Privileges via a Telnet/SSH Connection ........30

OL-31980 -01 19
Chapter 3 Installation

Power Connection
To operate the transcoder, you must connect it to an AC power source. For
information about connecting the chassis to AC power, see Appendix A - Technical
Specifications (on page 321).

As Cisco units are designed for continuous operation, some products do not have a
power switch. In this case the mains cord and/or DC power supply cable serve(s) as
the mains disconnect device.
WARNING:
Make sure that at least one end of the power cable(s) remains
easily accessible for unplugging, if you need to switch off the unit.
For example, ensure that the socket outlet is installed near the
product.

WARNING:
To avoid electrical shock, connect the three-prong plug on this
product to an earth-grounded three-pin socket outlet only.

20 OL-31980-01
Installing the D9859 Transcoder

Installing the D9859 Transcoder


Rack Mounted
The D9859 transcoder is a 1U unit with connector access at the rear panel. The
transcoder is intended for mounting in a standard 19" rack with minimum 1U
spacing between units to allow adequate ventilation/air flow.
The D9859 transcoder is vented from front to back. Multiple units can be stacked in a
rack, provided that adequate cooling is available.

Cooling
The D9859 transcoder is cooled by the use of internal fans. The air intake is from the
front and the air outlet is on the rear.
Note: Adequate cooling must be provided equaling 110 W (maximum) at 25°C per
unit to avoid overheating.
CAUTION:
The inlet air temperature must not exceed 50°C/122°F at any time.

Grounding
You must ensure that the unit is properly connected to ground in order to meet
safety and EMC requirements. Before any other connection is made, the unit must be
connected to a protected ground terminal as described below:
 Via the three wire power cord of the AC power supply. This connection is
mandatory.
 In addition, via the protective ground terminal on the rear panel of the unit. This
connection provides additional protection of the equipment.

Mounting the D9859 Transcoder to a Rack


1 Mount L-brackets in the rack to support each D9859 transcoder to be installed.
2 Place the transcoder in its position in the rack.
3 Mount the transcoder securely to the rack by securing the mounting flanges to
the rack using the four screws provided.
4 Make sure the air outlet holes on the back of the transcoder are not obstructed to
allow air flow from the front to the back of the chassis.

OL-31980 -01 21
Chapter 3 Installation

Connecting the AC Power to the D9859 Transcoder


1 Connect the power cord (supplied with the D9859 transcoder) between the rear
panel power receptacle and a 100 to 120/200 to 240 V AC power outlet.
2 Make sure that the power cable is connected to protective ground. See for
Grounding (on page 21) more information.
The D9859 transcoder is equipped with one power supply located in the rear of the
chassis. Note the location of the power supply in the event of alarms/warnings
resulting in replacement of a power supply. Alarm messages appear in the Mes sage
Log.

22 OL-31980-01
Rear Connector Panel

Rear Connector Panel


The following diagram show the rear connector panel of the D9859 transcoder:

The following table describes the function and type of the various connectors.

Connector Description Type

RF Inputs Each input accepts an LNB signal input. F


RF1 provides LNB power for use when no
external LNB power source is available. RF2
to RF4 require an external LNB power
source.
Reference Input For future use. BNC

ASI Input Asynchronous Serial Interface Input. BNC

ASI Outputs Three Asynchronous Serial Interface BNC


Outputs.
TS Output (Data) This is for the MPEGoIP and MPE outputs. RJ-45
The MPEGoIP output of the transport
stream is encapsulated in the IP packets to a
groomer for distribution. The MPE output
receives IP packets from the transport
stream.

Management For accessing the web GUI and upgrading RJ-45


the D9859 software application (code
downloading).

Cue Tone/Cue Trigger Program relay provides programmed 15-pin sub-D female
Relay Outputs responses for alarms, cue trigger states for
ad-insertion equipment, or a cue tone
output for connection to ad-insertion
equipment.

RS-232 Data RS-232 data output: 7 bits, even parity, 1 9-pin sub-D female
stop bit, up to 38.4 kbps. These outputs are
user-configurable via the Setup menu on
the front panel

OL-31980 -01 23
Chapter 3 Installation

Connector Description Type

Composite Video CVBS 1 and CVBS 2 provide two identical BNC


Outputs SD composite video outputs for monitoring
applications.
Balanced Audio Outputs Audio 1 and Audio 2 provide two stereo Terminal Blocks
pairs or four mono channels.

Ground Screw Grounding point for


the transcoder

Power AC power IEC 60320 Sheet 14

24 OL-31980-01
Connecting the Input/Output Signals

Connecting the Input/Output Signals


Connecting the RF Inputs
Connect up to four LNB RF cables to the RF connectors labeled RF1 through RF4 on
the rear of the unit.

Use 75-ohm (braid/foil or braid/braid), low insertion loss coaxial cable.


Each input accepts an LNB signal input. RF2 to RF4 require an external LNB power
source.

Connecting the ASI Input


If desired, connect to the ASI IN port to an asynchronous serial interface for uplink
monitoring.

Connecting the Video Outputs


Connector for the Video Output
The video output connectors are of the BNC type.

Connecting the Composite Video Output


Connect a video monitor to the CVSB 1 and CVSB 2 connectors. The two outputs are
identical. Use a 75-ohm double-braided coax cable.

Connecting the Balanced Audio Output


1 Connect the AUDIO 1 and AUDIO 2 balanced audio outputs to monitoring
equipment. Use a multi-conductor, pluggable cable from the transcoder's
AUDIO 1 and AUDIO 2 (Left and Right) terminals to your equipment, as shown
in the following illustration.

Connector Connector type

Terminal Block

OL-31980 -01 25
Chapter 3 Installation

2 Feed the stripped ends of the positive, negative and ground wires into the
appropriate terminals as labeled, and then screw the terminal screws (located on
the top of the terminal block) finger tight to each wire.

Connecting the Ethernet Management Interface


The RJ-45 interface for 10/100/1000BASE-T Ethernet is currently intended for
upgrading/downloading the software application.
Hint: If you experience problems with the 10BASE-T Ethernet it is advised that you
change it to a 100BASE-T connection.
You must set up the IP address, the default gateway and the subnet mask to match
the network connection. This is done through the front panel menu. For more
information, see IP (on page 69).
Proper cables are required for reliable Ethernet operation; to run over a maximum
segment length of 100 m the cable has to comply with the EIA/TIA Category 6 wire
specifications.
1 Connect a crossed RJ-45 cable between the Ethernet connector on the D9859
transcoder and the Ethernet port of your PC.
Note: You need a crossover cable if you want to connect the Ethernet interface of
the D9859 transcoder directly to another Ethernet device without using a hub or
switch.
2 Set up the IP address on the D9859 transcoder (via the front panel display). For
information on setting up the IP address via the front panel, see IP (on page 69).

Connecting the IP TS Output


The RJ-45 interface IP TS OUT is 10/100/1000BASE-T Ethernet. It is intended for
both MPEGoIP and MPE outputs. The MPEGoIP output of the transport stream is
encapsulated in the IP packets to a groomer (for example, Cisco D9900 Digital
Content Manager) for distribution. The MPE output receives IP packets from the
transport stream.
Note: For reliable Ethernet operation up to the maximum segment length of 100 m,
ensure that the cable complies with the EIA/TIA Category 6 wire specifications.
Connect a crossed RJ-45 cable between the Ethernet connector (DATA port only) on
the D9859 transcoder and the Ethernet port of the equipment after the D9859
transcoder. The equipment after the D9859 transcoder could be an IP router or a
switch.

26 OL-31980-01
Connecting the Input/Output Signals

Connecting the ASI Outputs


Proceed as follows to connect to the ASI outputs:
1 Connect the output signal from the D9859 transcoder ASI OUT connectors. A ll
three outputs, ASI OUT 1, 2 and 3 are identical.
2 Use a Belden “Brilliance” cable with foil/braid construction. The shield must
provide 99% or better shielding effectiveness.
The equipment after the D9859 transcoder could be a Cisco D9887 HDTV
Modular Receiver or Cisco D9854 Advanced Program Receiver.

Connecting an External Alarm System


The D9859 transcoder is equipped with a connector labeled Cue Tone/Relay which
provides alarm relay outputs for remote alarm signaling. This connector provides
Cue Tone, Cue Trigger and Alarm relay functionality. See Connecting the Cue
Tone/Cue Trigger Interface (on page 28) for more information on Cue Tone and Cue
Trigger equipment connections. These contact closure outputs are user-configurable
via the Setup Menu on the front panel.

The Alarm output connector is a 15-pin sub-D female connector. The diagram below
shows the connector and the pin allocation table for the Alarm output pins.

The connector pin states depend on the selected Relay Mode. The Relay Mode is set
on the front panel. For more information, see Cueing (on page 89).

Changing the Relay Mode for Alarm Monitoring


The Alarm relay is a program relay that can be configured to provide programmed
responses for alarms, warnings, cue trigger states for ad-insertion equipment, or a
cue tone output for connection to ad-insertion equipment. As a default, the Alarm
Relay is configured for Trigger mode.
1 On the front panel menu, go the Main: Setup: Outputs, and select Cueing.
2 Use the down arrow key to scroll through the Cueing menu to Relay Mode.
3 Select Relay Mode, change the state to Alarm and press the Select key to save
the new setting. As a result, the rear panel connector pin states will change to
that shown in the table below for Alarm mode.

Connector Normally Common pin Normally open Relay Mode


closed pin pin

10 1 11 10 15 Trigger

15 10 11 Alarm (default)
15 CUE TONE/RELAY

OL-31980 -01 27
Chapter 3 Installation

Note: A Normally closed state implies the state when power is applied to the relay
in a normal operating state, without a trigger or alarm condition present.

Connecting the RS-232 Data Interface


The DCE DB-9 female connector is intended for low-speed data: 7 bits, even parity, 1
stop bit, up to 38.4 kbps (default). These outputs are user-configurable via the Setup
Menu on the front panel.

The interconnect cable from the D9859 transcoder to a PC should be straight through
(for example, no handshaking), shielded and equipped with a DB-9 male connector
at one end to mate with the rear panel RS-232 Data interface, and a female DB-9
connector to connect to the PC.

RS-232 Data Connector Pin Allocation


The table shows the RS-232 Data connector and the pin allocation:

Connector Normally Common pin


closed pin

1 1 Not connected
2 TxD

3 RxD

4 Not connected
9 5 Ground

6 Not connected

7 Not connected

8 Not connected

9 Not connected

Connecting the Cue Tone/Cue Trigger Interface


The D9859 transcoder is equipped with a connector labeled Cue Tone/Relay for
alarm relay outputs for remote alarm signaling. This connector provides Cue Tone,
Cue Trigger and Alarm relay functionality. These outputs are user-configurable via
the Setup Menu on the front panel.
The connector is a 15-pin sub-D female connector. The following diagram shows the
connector and the pin allocation table for Cue Tone, Cue Trigger and Alarm relay
connections.

28 OL-31980-01
Connecting the Input/Output Signals

Connector Pin Pin allocation

1 Cue Trig 1

2 Cue Trig 2

3 Cue Trig 3

4 Cue Trig 4

5 Cue Trig 5

6 Cue Trig 6

7 Cue Trig 7

8 Cue Trig 8

9 Not connected
10 Alarm - Ground

11 Alarm - Normally open

12 Chassis ground

13 Cue Tone -

14 Cue Tone +

15 Alarm - Normally closed

Connecting the Cue Tone Interface


Connect the Cue Tone pins, 13 and 14 to a device to facilitate ad -insertion using
DTMF Analog Cue Tones.

Connecting the Cue Trigger Interface


Connect the Cue Trigger pins (1 to 8) to up to 8 serial control devices or a device to
control ad-insertion. These outputs are user-configurable on the front panel menu.

Configuring Open-collector Outputs


The D9859 supports decoding of SCTE-35 messages with DTMF descriptor. The
D9859 outputs tones or sets the open collector contacts according to the content of
the DTMF descriptor in the Cisco D9054 HDTV Encoder and the Cisco D9036
Modular Encoding Platform. For information on the open-collector output settings,
see the Cisco D9054 HDTV Encoder Installation and Operation Guide and Cisco D9036
Modular Encoding Platform Installation and Configuration Guide.

OL-31980 -01 29
Chapter 3 Installation

Setting Admin User Privileges via a Telnet/SSH


Connection
Administrator User Privileges
Up to 10 usernames/passwords can be defined for login use via a telnet, SSH, or
Web GUI (for example, http) session on the D9859 transcoder.
When a user tries to login via a telnet, SSH, or http connection, the user is required
to provide a username and a password. The user is granted access only if this
username/password pair exists in the authentication table.
The factory preset "Admin" account has Admin privileges and is allowed to add new
users, delete users, change usernames, and modify its own passwords. Users with
non-Admin privileges (for example, User and Guest) are only allowed to modify
their own passwords.

Starting a Telnet/SSH Session


To start a communication session with the transcoder, use a utility such as Tera
Term Pro or PuTTY.
Proceed as follows to log into a new connection using Tera Term:
1 In the New Connection window, enter the IP address in the Host field.
2 If you want to start a telnet session, select Telnet and enter 23 in the TCP Port#
field.
3 If you want to start an SSH session, select SSH and enter 22 in the TCP Port#
field.
4 Click OK.
5 If you started a Telnet session:
a At the Login prompt, type the username and press Enter.
b At the Password prompt, type the password and press Enter.
Note: The username and password are case-sensitive. The default username
is admin and the default password is localadmin.
c Type lr and press Enter.
6 If you started an SSH session:
a A Security Warning message is displayed (first time only). Select Add this
machine and its key to the known hosts list and click Continue. The SSH
Authentication window is displayed.
b In the User name field, type the username, admin.

30 OL-31980-01
Setting Admin User Privileges via a Telnet/SSH Connection

c In the Passphrase field, type the password, localadmin. Wait a few seconds,
until the Use rhosts to log in is disabled.
Note: The username and password are case-sensitive. The default username
is admin and the default password is localadmin.
d Click OK.
7 Type lr and press Enter.

Adding a New User


1 At the admin prompt, type pwd add_user and press Enter.
2 At the NEW USERNAME prompt, type a new username and press Enter.
3 At the NEW PASSWORD prompt, type a new password and press Enter.
Note: The new password must follow the rules configured in the Password
Complexity parameter. For more information, see To Change the User Login
Passwords (on page 245) for the web GUI or Setup Menu: IP (on page 68) for the
Front Panel.
4 At the CONFIRM NEW PASSWORD prompt, type the new password again and
press Enter.
Note: The New Password and Confirm New Password should be identical.
5 At the NEW USER PRIVILEGES prompt, enter the type of account you want to
assign the user. The following table illustrates the different login types:

Account Type Enter Access

Guest 3 View settings only.

User 2 View and edit settings.

Admin 1 View, edit settings, and add/delete user accounts.

6 At the ADMINISTRATOR PASSWORD prompt, type the administrator's


password and press Enter.

Deleting a User
1 At the admin prompt, type pwd del_user and press Enter.
2 At the USERNAME prompt, type the username you want to remove and press
Enter.
3 At the ADMINISTRATOR PASSWORD prompt, type in the administrator's
password and press Enter.

OL-31980 -01 31
Chapter 3 Installation

Changing a Username
1 At the admin prompt, type pwd username_change and press Enter.
2 At the CURRENT USERNAME prompt, type the username you want to edit and
press Enter.
3 At the NEW USERNAME prompt, type the new username and press Enter.
Note: Ensure that the new username does not match any of the usernames
already defined in the authentication table.
4 At the ADMINISTRATOR PASSWORD prompt, type the administrator's
password and press Enter.

Changing a Password (allowed by all Users)


Passwords can be changed by all users.
1 At the admin prompt, type pwd password_change and press Enter.
2 At the CURRENT PASSWORD prompt, type the current login password you
want to change and press Enter.
3 At the NEW PASSWORD prompt, type a new login password and press Enter.
4 At the CONFIRM NEW PASSWORD prompt, type the new login password
again to confirm and press Enter.
Note: The new password and the confirm new password should be identical.
Each user, including the admin user, can modify only his own password.

Printing the List of Users


At the admin prompt, type pwd list_users and press Enter.

Note: Only usernames will be printed. Passwords will not be visible.

Resetting the Login Credentials


At any time, the user authentication table can be reset from the front panel. This
option is under the Setup: IP: IP menu. Scroll down to Reset Credentials and press
SELECT. Press and then press SELECT to confirm the operation. A new login
username and randomly generated password will be displayed on the f ront panel
display for approximately 30 seconds. The new account will have Admin privileges.
We recommend that this account be replaced by a login username and password
chosen by the administrator. To change the username and password, you must be an
Admin user. Refer to To Change the User Login Passwords (on page 245).
Note: After this recovery procedure, all existing user accounts will be lost.

32 OL-31980-01
4 Chapter 4
Front Panel Operation
Overview
This chapter describes how to set up the Cisco D9859 Advanced
Receiver Transcoder using the front panel keys and display. This
information is primarily applicable for standalone operations.

In This Chapter
 About the Front Panel ........................................................................34
 Locking/U nlocking the Front Panel .................................................38
 Startup Screen.....................................................................................39
 Main Menu ..........................................................................................43
 Status Menu ........................................................................................44
 Setup Menu .........................................................................................56
 About Menu ......................................................................................124
 Versions Menu ..................................................................................126
 Diagnostics Menu .............................................................................129

OL-31980 -01 33
Chapter 4 Front Panel Operation

About the Front Panel


The D9859 transcoder is operated using controls and indicators on the front panel.
These include the numeric keypad, the Navigation/Selection keypad, the LCD, the
Alarm and Signal indicators. These are shown in the following illustration.

LCD
The LCD provides information on the selections available at any menu level, current
settings for parameters, and certain status and alarm indications. This is a 2x40,
backlit LCD display. The top line may be status data or identifier information. It can
also display optional functions available for tuning operations. The bottom line will
show selections or parameter values available using the navigation/selection
keypad. The items are selected by pressing the SELECT (center key) or the (down
arrow) key on the navigation/selection keypad.

Keypad
The numeric keypad is used to enter alphanumeric values. The MENU key sets the
software to the initial menu and returns to the previous menu. The MENU key can
also be used to cancel a numeric entry at any point during the entry sequence, and
the (left arrow) key allows backspacing through the entry.

Front Panel LEDs


The functions of the LEDs are described in the table below.

LED Signal Explanation


State/Color

ALARM Red Solid for five seconds indicates a Warning.

Red Flashing indicates an Alarm.

SIGNAL Green Solid indicates all of the following conditions:

 active RF inputs are enabled, locked to a


signal, and are not muted.

 all outputs are operating without an error.

34 OL-31980-01
About the Front Panel

LED Signal Explanation


State/Color

Green Flashing indicates one of the following


conditions:

 difficulty with an input, route or output.

 one or more RF inputs, or the ASI input are


not synchronized.

 one or more outputs are routed, but muted


by a fault condition.

 no RF signal is present or detected, or it is


muted.

 transcoder is not authorized to receive the


program.
Off Off indicates all of the following conditions:

 no RF input signal is available, enabled or


detected, or the input is muted.

 no ASI input is present

 no valid inputs are available.

Navigation/Selection Keypad
Throughout this manual, there are references to pa rts of a keypad on the front of the
receiver. The navigation keys (LEFT, RIGHT, UP and DOWN) and the SELECT key
are the primary controllers. Each navigation key performs various functions,
depending on the current state of the menu system (i.e., sometimes the left
navigation key backspaces over an entry and sometimes moves the cursor to a
different menu item). Once the cursor is over the desired function, pressing the
SELECT (center key) key selects the current item. Pressing the SELECT key stores
any entered values.
The following is the Navigation/Selection keypad, which changes its function,
depending on the current state of the menu:

The following table shows which parts of this integral interface are being referenced
by which term.

OL-31980 -01 35
Chapter 4 Front Panel Operation

Button Function

LEFT Arrow key When moving through menus,


it highlights the menu item to
the left. When entering data, it
moves the cursor to the left. In
some menus, it backspaces
over the data entry.

RIGHT Arrow When moving through menus,


key it highlights the menu item to
the right. When entering data,
it moves the cursor to the
right.

UP Arrow key Highlights the menu item


above.

DOWN Arrow Highlights the menu item


key below.

SELECT key Runs the highlighted


command or opens the
highlighted menu.

INFO key Press the key on the lower left


of the numeric keypad for
context-sensitive help
messages, when available.
When entering characters in
numeric or alphanumeric
fields, this key can be used to
toggle between upper and
lower case.
MENU key Press the key on the lower
right of the numeric keypad.
Starts the on-screen display.
Also functions as the Escape
key so you can back out of
menus and data entry fields.

36 OL-31980-01
About the Front Panel

Button Function

Alphanumeric Pressing the numeric keys 2-9


Entry once will enter the respective
digit into a data entry field.
Pressing these buttons again
will enter the first of the letters
displayed beside the number.
Repeatedly pressing the
button will toggle through all
of the key's possible choices.
When entering text, the 1
button can be used to insert
spaces (press twice).
To delete a character, press 0
twice.

ADV Toggles between Program


Entry and Channel number.
MAP Edit, insert, and delete Digital
Program Mapping (DPM)
Modes on Program Entries or
on PIDS within Program
Entries.

APPLY Activates current changes


without having to exit the
menu.

NAV For future use.

OL-31980 -01 37
Chapter 4 Front Panel Operation

Locking/Unlocking the Front Panel


Depending on the customer’s default settings, the receiver is shipped with a locked
or unlocked front panel. You can lock or unlock the front panel using the front panel
keypad.

Proceed as follows to unlock the front panel using the front panel keypad:
1 From the Startup screen, press SELECT and then INFO. This will unlock the
front panel keypad and allow you to make changes to all the operating
parameters; however, if the keypad remains untouched for the duration of the
set timeout period (default is 60 seconds), the keypad will change back to the
Lock state unless you change the keypad state on the Admin Menu. Likewise
you can toggle the keypad lock state back using SELECT and INFO at any time,
provided the KB Lock state on the Admin Menu is Enabled. For more
information on front panel keypad buttons, see Keypad (on page 34).
Note: If the lock level is 3 or 4, you must enter a password to unlock the front
panel. For more information on lock level password, see Setup Menu: Admin (on
page 57).
2 To disable Lock completely, navigate to Setup, Admin, KB Lock in the LCD
display and press the SELECT key.
3 Change the KB Lock state from Enabled to Disabled.
4 The front panel will now be unlocked, allowing you to change any of the
operating parameters.
To lock the front panel, perform the same procedure, except use to change
the state. In this case, you will not be prompted to confirm the operation.

38 OL-31980-01
Startup Screen

Startup Screen
Main Structure
On power-up and initialization, the startup screen is displayed similar to that shown
below. The screen also indicates the signal status.

Channel Authorization Status


From the startup screen, press the right or left arrow keys on the front panel keypad
to move to the PE entry authorization status screen. This screen indicates whether
the selected channel is authorized.

Auth Status Description

Y Indicates the channel is authorized.

N Indicates the channel is not authorized.

LCD Panel
The LCD panel displays basic signal and program information in the LCD display,
as described in the following illustration:

LCD Setting Description

PE Program Entry.
The transcoder supports eight Program Entries (PE1 to
PE8). PE1 is the decode channel and is available at the
analog outputs. PE2 to PE8 are available for the
transcoded channels on the ASI and MPEG over IP
outputs.
12345 Channel for program monitoring.

Channel name Name of the monitored program.

RF Active RF input port.


Note: ASI will be shown if the ASI input port is active.

OL-31980 -01 39
Chapter 4 Front Panel Operation

LCD Setting Description

Freq: Downlink frequency of the tuned signal in GHz.

Lvl: Signal level in dBm.

Marg: Carrier-to-noise (C/N) margin in dB.


DEGD The Degraded indicator only appears if there is
degraded tuning information in use. This occurs if the
SI tables are not consistent on the incoming stream. The
receiver will attempt to identify the service list based
on the information available. Check the SI acquisition
and stream information to ensure that the channels,
network, and tuning information are operating as
expected.

LCD Symbol
Various symbols will periodically appear in the top right-hand corner of the LCD
panel, indicating which user actions are currently acceptable. The following displays
the location of the symbol:

The following table describes the various symbols:

LCD Symbol Description

The Hourglass indicates that parameters are being


saved in the background. You can continue to perform
any operation desired.
Note: If a power-cycle/interrupti on occurs while the
hourglass is displayed, some parameters may not be
saved. Refrain from powering off the unit while the
hourglass is displayed.
The Info symbol indicates that the INFO key is active.
In most cases, this will display contextual information
on the LCD screen.
The Select symbol indicates that the SELECT key is
active.
The Left/Right symbol indicates that the
RIGHT/LEFT arrow key is active; e.g., pressing the
RIGHT/LEFT arrow key will have an affect, such as
moving the cursor to the right/left.

40 OL-31980-01
Startup Screen

LCD Symbol Description


The up/down symbol indicates that the UP/DOWN
arrow key is active.

The Download In Progress (DL) symbol indicates that


the transcoder is currently downloading a software
update and storing it into memory in the background.
Note: Service interruption occurs during a reboot,
which is always required when the transcoder's
software is updated.

The Download Trigger (DT) symbol indicates new


software is ready for download, but a download
trigger by the transcoder is required before it will be
downloaded.
Note: Service interruption occurs during a reboot,
which is always required when the transcoder's
software is updated.

The Download symbol indicates that a software


download for a version of software already in memory
has been detected.

The Disaster Recovery (DR) symbol indicates that a


disaster is declared on the current transcoder.

o The Session Open symbol indicates that you are


changing a group of related items.

Assigning Program to the Program Entry


To assign a program to the PE:
1 Press MENU until you display the startup screen.
PE # Ch #

PE1 706 Channel Name s

RF1 Freq:12.658 Lvl:-50 Marg:11.6

The PE (Program Entry) channel is initially displayed.


Note: PE1 is the default.

OL-31980 -01 41
Chapter 4 Front Panel Operation

2 Press the ADV key to select PE1.


PE

PE1 1 Channel Name s

RF1 Freq:12.658 Lvl:-50 Marg:11.6

3 Press to scroll through the available program entries.


4 Press ADV again to select the channel number.
Ch #

PE1 1 Channel Name s

RF1 Freq:12.658 Lvl:-50 Marg:11.6

5 Directly enter the channel number using the 0 to 9 keys and press SELECT to
apply the channel number, or press to scroll through the available channels.

Deleting a Program from the Program Entry


To delete a program from the PE:
1 Press MENU until the startup screen appears.
PE # Ch #

PE1 706 Channel Name s

RF1 Freq:12.658 Lvl:-50 Marg:11.6

The PE channel is displayed.


Note: PE1 is the default.
2 Press the ADV key to select PE1.
PE

PE1 1 Channel Name s

RF1 Freq:12.658 Lvl:-50 Marg:11.6

3 Press the to scroll through the available program entries.


4 Press ADV again to select the channel number.
5 Enter the channel number 0 with the numeric keys and press SELECT to apply
and delete the program.

42 OL-31980-01
Main Menu

Main Menu
Operation of the D9859 Advanced Receiver Transcoder begins at the Main menu.
From the startup screen, press the MENU key to view the Main menu.
Main Menu 1/2 i s Main Menu 2/2 i s

Status Setup About Versions Diagnostics

Select the desired function by moving the cursor left or right by pressing the LEFT or
RIGHT arrow key. Once a selection is made by pressing the SELECT key, the LCD
presents the second menu level for the selected function. Succeeding levels fo r each
function include all the hierarchical levels for the function in the front panel LCD.

OL-31980 -01 43
Chapter 4 Front Panel Operation

Status Menu
Structure
To view the Status menu from the Main menu, press the SELECT key. The Status
menu indicates the status of the input and output signals, the video and audio
services, and allows you to browse and/or configure the alarms and warnings.
The Status menu is split into four parts; General, Services, TS Input, TS Output, and
IP. Each parameter is described in this section. For instructions on how to select and
store settings, see About the Front Panel (on page 34).
The Status menu has the following structure:

44 OL-31980-01
Status Menu

Status Menu: General

Menu Item Description Parameters

Input Indicates the currently selected input RF1 to RF4, or ASI


source.

Status Indicates whether the input signal is Locked - Indicates the receiver is
locked. locked to a carrier with no valid
content.
Lock+Sig - Indicates the receiver
is locked to a carrier with valid
content.
No Lock - Indicates the receiver
is not locked to a carrier.

Rate (Mbps) Indicates the bit rate of the input transport


stream, in Mbps.

Level (dBm) Indicates the strength of the received


signal level, in dBm.

PE Select the Program Entry to view. PE1 to PE8

Mode Indicates how the program is scrambled. Unkn, DES, DVB, BISS1, BISS2,
or BISS3
Auth Indicates whether the receiver is Yes or No
authorized to receive the program.
Enc Indicates whether the received program is Yes or No
encrypted.

Scr Indicates whether the received program is Yes or No


scrambled.

CA System Indicates the type of Conditional Access SA, BISS, or FTA (Free To Air)
(CA) system used by the program.

Video Indicates the video encoding, format, and MPEG1, MPEG2, or H264 format
resolution of the received program. with a resolution of:
SD480i/2997, SD480i/3000,
SD576i/2500, HD720p/5000,
HD720p/5994, HD720p/6000,
HD1080i/2500, HD1080i/2997,
or HD1080i/3000
Unknown or Unsupported

Rate (Mbps) Indicates the bit rate of the received video


stream, in Mbps.

Alarms Displays the number of active alarms.

Warnings Indicates the number of active warnings.

OL-31980 -01 45
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Browse Select to view the current active alarms


and warnings, including additional details.
Clear All Select to clear all the active alarms and Abort, Continue. Select Abort to
warnings. You will be prompted to verify cancel the operation or Continue
whether you want to clear all the alarms to clear all the warnings and
and warnings. alarms.

Current Date and Displays the current SNTP date and time,
Time if available. Otherwise, the current TDT
date and time is displayed.
Note: This is displayed as local time.

Current TDT Date Displays the current TDT (Time and Date
and Time Table) date and time received from the
DVB stream.
Note: This is displayed as local time.

Current SNTP Date Displays the current SNTP (Simple


and Time Networking Time Protocol) date and time
if IRD receives a valid reply from the NTP
server.
Note: This is displayed as local time.

Status Menu: Services

Video

Menu Item Description Parameters

Video Indicates the video encoding, format, MPEG1, MPEG2, or H264 format
and resolution of the received with a resolution of: SD480i/2997,
program. SD480i/3000, SD576i/2500,
HD720p/5000, HD720p/5994,
HD720p/6000, HD1080i/2500,
HD1080i/2997, or HD1080i/3000
Unknown, or Unsupported

Rate (Mbps) Indicates the bit rate of the received


video stream, in Mbps.

3:2 Pulldown Indicates whether the 3:2 pulldown is Yes, No or Recent


detected, was recently detected, or
not detected in the input video
stream.

FPS Indicates the frame rate of the input Typically 25.0, 29.97, 30.0, 50.0,
video stream. 59.94, 60.0, unknown or
unsupported

46 OL-31980-01
Status Menu

Menu Item Description Parameters

Stream AR Indicates the aspect ratio of the 4:3, 14:9 or 16:9


incoming video stream.

Act Conv Displays the actual applied aspect None, 4:3 L/B, 4:3 P/B, 14:9, 14:9,
ratio conversion. 4:3 F/H or 16:9 F/W

Audio

Menu Item Description Parameters

AUD Indicates the current audio decoder AUD1 for audio channel Aud1.
status.
AUD2 for audio channel Aud2.
AUD1 to AUD4 for two stereo
audio channels.

Format Indicates the format of the audio None, Sine, Pink, Beep, MPEG1L1,
input stream. MPEG1L2, MPEG2L1, MPEG2L2,
AC3, LOAS AAC, ADTS AAC,
LOAS HEAAC, ADTS HEAAC, or
DDP

BR (Kbps) Indicates the bit rate of the audio


input stream, in kbps.

Buffer Indicates the buffer level of the input


audio stream, in bytes.
SFR (KHz) Indicates the sample rate of the input 32.0, 44.1, or 48.0 kHz
audio stream, in kHz.

DDP IND Indicates the presence of Dolby ® OFF or ON


Digital Plus frames within a Dolby
Digital Plus audio stream.

DUAL-MONO IND Indicates the presence of dual mono OFF or ON


audio outputs in the audio stream. If
the dual mono indicator is set to ON,
the left and right outputs will
correspond to mono channel 1 and
mono channel 2 respectively.

Status Menu: TS Input

Input

Menu Item Description Parameters

Input Indicates the active input port receiving RF1, RF2, RF3, RF4, or ASI
the signal.

OL-31980 -01 47
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Status Indicates the current signal lock status Locked - Indicates the receiver is
for the input. locked to a carrier with no valid
content.
Lock+Sig - Indicates the receiver is
locked to a carrier with valid
content.
No Lock - Indicates the receiver is
not locked to a carrier.

Rate (Mbps) Indicates the bit rate of the received in Mbps


input signal.

Level (dBm) Indicates the signal level of the received in dBm


signal.
SymRate Indicates the Symbol Rate of the in Msymbols/second
received signal.
FEC Indicates the FEC (Forward Error N/A, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6,
Correction) rate of the received signal. 7/8, 8/9 or 9/10

Modulation Indicates the modulation type for the N/A, QPSK, 8PSK, DVB-S, DVB-
received signal. S2 or 16QAM
Pol Indicates the signal polarization setting. Horiz (Horizontal), Vert (Vertical)
This setting is only applicable when or Auto
LNB Power is set to H-NIT or V-NIT.
The selected setting must match the
polarization of the transmitted signal.

IQ Tuner Indicates the IQ (Input Signal Inversion) Inv or NonInv


for the received signal.

IQ Status Indicates the input signal spectrum Auto, Opposite, or Normal


inversion setting (IQ), which allows the
operator to track and select inverted
and non-inverted digital signals.

Dnlk Freq (GHz) Indicates the current downlink in GHz


frequency.

L-Band Indicates the current L-Band frequency. in MHz

Pilot Present Indicates whether a Pilot is present for Yes, No, or N/A
the received signal. The Pilot is set on
the modulator for input signal
synchronization purposes.

C/N (dB) Indicates the current Carrier-to-Noise in dB


ratio.

48 OL-31980-01
Status Menu

Menu Item Description Parameters

C/N Margin (dB) Indicates the current Carrier-to-Noise Values can be displayed in the
Margin for the received signal. The range of -32.0 to +30.0 dB.
Carrier-to-Noise margin is the actual
distance that C/N is from the noise
threshold.

PER Indicates the current PER (Packet Error


Rate) of the received signal (DVB-S2).

PVBER Indicates the PV (Post-Viterbi) BER for


the received signal (DVB-S).

LDPCBER Indicates the LDPC (Low Density Parity


Check) error rate for the received signal
(DVB-S2).

AFC (MHz) Indicates the current Automatic in MHz


Frequency Control count.
UEC Indicates the current Uncorrected Error
Count for the received signal.
CEC Indicates the current Corrected Error
Count for the received signal (DVB-S).

Clear Counts Select this option to clear the error


counters.

ASI Link Indicates whether there is a transport Error, Ok, or N/A


stream link error.

Transport Indicates the current transport Error, Ok, or N/A


synchronization status.

Packet Size Indicates the packet size (in bytes) for 188, 204, or N/A
the ASI input.
Net Name Indicates the name assigned to the Up to 12 alphanumeric characters.
network.

NetID Indicates the Network ID of the uplink 1 to 65535


signal the receiver is to receive when
using the selected preset. The receiver’s
Network ID must match the Network
ID associated with the transmitted
signal that identifies the NIT to be used.
Note: Each network must be assigned a
unique ID (number).

TxID Indicates the Transport ID. 1 to 65535

LNB Stat Indicates the current Low Noise Block No Load, Over Loaded, Over
(LNB) connection status. Temperature, Short Circuit,
Disabled, Normal or N/A

OL-31980 -01 49
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Polar Indicates the polarity of the LNB Power Off, 13V, or 18V
supply.
LO Select Indicates whether a 22 kHz tone is On or Off
available on input port RF1. This is
applicable for dual-band applications.

Program PIDs

Menu Item Description Parameters


PE Select the Program Entry to view. PE1 to PE8

Stream Indicates the name assigned to the Up to 4 alphanumeric


Program Entry. characters
Detail Indicates any detail associated with MPG1 VID, MPG2 VID, 422
the program PID (e.g., MPG2 PID). VID, H264 VID, HD VID, MPG4
VID, MPG AUD, MPG2 AUD,
DVB AC3, DVB DDP, AAC
AUD, HEAAC, AUD, MPG4
AUD, DBE AUD, DTS AUD,
DVB TXT, DVB VBI, DVB
SUBT, DVB ASYN, DVB SYNS,
DVB SYND, DVB MPE, DVB
DCAR, DVB OCAR, SA VBI,
ATSC AC3, ATSC DDP, SA
UTLD, SCTE DPI, SA HSD, SA
CDDL, SA WBD, SA SUBT,
ECM, EMM, PCR, or
UNKNOWN

PID Indicates the program PID number. 1 to 8192

Present Indicates whether the PID is present Yes or No


in the incoming stream.

Program Status

Menu Item Description Parameters

PE Indicates the Program Entry PE1 to PE8


number.

50 OL-31980-01
Status Menu

Menu Item Description Parameters

SR Status This displays the status of an Not Started - Indicates that an event has
alternate authorized not started.
program/service from the same
Primary - Indicates that a service
transport stream when the receiver
replacement event is active, but the
is not authorized to view the
primary program is being displayed.
primary program. This is an uplink
initiated function that maps the Alternate - Indicates that a service
alternate service to the original replacement event is active, and that the
(primary) service PIDs, replacing receiver has tuned to and is displaying
the original service with the the alternate program/event as it is not
alternate service at the digital authorized to view the scheduled event.
transport output. No local
intervention is required by the
receiver operator for provision of
this service replacement feature.

SR Event Type Indicates the type of service None - Indicates that no service
replacement event. replacement event is scheduled.
Scheduled - Indicates that all
transcoders will tune to the alternate
program at the scheduled time. This
status applies to PE1 to PE8.
CA - Indicates that only transcoders
unauthorized to view the scheduled
program will tune to the alternate
program according to the selected
authorization tier bits. This status
applies to PE1 to PE8.
Cue Trigger - Indicates that only
transcoders authorized by the Cue
Trigger mask will tune to the scheduled
program/event.
Note: The Cue Trigger service
replacement event type is not
supported in the current release.

SR Event Start Displays the start time of the


service replacement event when
one is scheduled; otherwise, the
default start time is displayed. The
default start time is 2007/09/01
00:00:00.

SR Event End Displays the end time of the service


replacement event when one is
scheduled; otherwise, the default
end time is displayed. The default
end time is 2007/09/01 00:00:00.

OL-31980 -01 51
Chapter 4 Front Panel Operation

Status Menu: TS Output

Output Status

Menu Item Description Parameters

Output Indicates the output type. ASI or MPEGoIP

Rate (Mbps) Indicates the current output bit rate. 0 to 213 Mbps

Free (Mbps) Indicates the available bandwidth, in Mbps


(without stuffing).

Status Menu - IP
To view the IP menu from the Status menu, press the RIGHT arrow key four times.
The IP menu provides Link, Redundancy, and MOIP status information.
The IP menu has the following structure:

Link Status
The Link Status parameters display the port information, such as the status, speed, duplex
and crossover. Port 1 is the management port and port 2 is the data port.

Redundancy Status
The Redundancy Status is not supported.

Global Status

Menu Item Description Parameters

Engine Error This is not supported.

52 OL-31980-01
Status Menu

Menu Item Description Parameters

Stream Overflow Indicates the MPEG over IP transport stream Yes or No


overflow status.

Combined User Displays the configured output bit rate.


Rate

Actual Rate Port Displays the current output bit rates for the control 0 to 206 Mbps
1/2 port (Port 1) and data port (Port 2).

Stream Status

Menu Item Description Parameters

PE ID Displays the program entry channel. 1

Stream Port1/Port2 Indicates the stream status of the control port (Port Stopped, Suspended,
1) and data port (Port 2). Active, or Muted
Content Overflow Indicates if the incoming transport stream rate is Yes or No
higher than the configured output bit rate.
Link Overflow Indicates if the configured output bit rate is close Yes or No
or higher than the current Ethernet link speed for
the Ethernet port used for MPEGoIP output.

Status Menu - DR
To view the DR (Disaster Recovery) menu from the Status menu, press the RIGHT
arrow key five times. The DR menu provides the current disaster recovery status
information. For more information on disaster recovery, see Disaster Recovery (on
page 6).

The DR menu has the following structure:

OL-31980 -01 53
Chapter 4 Front Panel Operation

Global Status

Menu Item Description Parameters

State Displays the current disaster recovery status. The No Disaster, D/R In
three statuses are: Progress, D/R Disabled

 No Disaster - The unit is in a normal state.

 D/R In Progress - The unit has detected a loss


of input and it is searching for a backup
transport using the configured search path.
The configured search path is displayed in the
Transport Status menu.

 D/R Disabled - The disaster recovery feature is


temporarily disabled. To enable disaster
recover, see Setup Menu: DR (on page 121).
Signal Loss Timer Indicates the time, in seconds, the unit must wait 5 to 2160000
(after detecting a signal loss) before declaring a
disaster.
Signal Lock Timer Indicates the time, in seconds, the unit must wait 5 to 255
for a signal lock before declaring that the signal is
not usable and move on to the next search location
in the search path.

Verify Timer Indicates the time, in seconds, the unit must wait 10 to 255
for the PAT table to verify the signal has a valid
transport.

Backup Channel Status

Menu Item Description Parameters

PE Displays the program entry. PE1 to PE8

Backup Channel Displays the channel number assigned to the –


selected backup transport.

Transport # Displays the backup transport number for the 1, 2, or 3


program entry selected.

Backup Transport Status

Menu Item Description Parameters

Backup Indicates the configured backup transport entry 1, 2, or 3


number.

54 OL-31980-01
Status Menu

Menu Item Description Parameters

Input, NetId, Freq For information on the tuning parameters, see –


(GHz), SymRate, Status Menu: TS Input (on page 47).
FEC, OrbPos, E/W,
Note: The RF input must be configured to match
Pol, Modulation,
the bandwidth of the backup parameters.
Rolloff, Config by

OL-31980 -01 55
Chapter 4 Front Panel Operation

Setup Menu
To view the Setup menu from the Main menu, press the RIGHT arrow key once and
the SELECT key. The Setup menu is split into eight sections: Administration, TS
Input, IP, Services, Outputs, CA, Alarms/Warnings, and Noise Cutoff. For
instructions on how to select and store settings, see About the Front Panel (on page
34).
The Setup menu allows you to set all the parameters associated with the following:

 Administration - lock level, password, factory reset, keypad lock, download


mode and date and time
 TS Input - frequency parameters for acquiring and locking on to an RF signal, or
receiving an ASI input
 IP - parameters for setting up the Ethernet ports

 Services - audio video, captions, and VBI


 Outputs - alarm relays, cue tone/cue trigger setup, parameters f or setting up the
transport stream out, which includes DPM and transcoding
 CA - conditional access

 Alarms/Warnings - enables alarms/warnings traps and relays

 Noise Cutoff - muting thresholds

 DR - global, backup channel, and backup transport parameters for disaster


recovery

The Setup menu has the following structure:

56 OL-31980-01
Setup Menu

Setup Menu: Admin


To view the Admin menu from the Setup menu, press the SELECT key.

For instructions on how to select and store settings, see About the Front Panel (on
page 34).
The Admin menu has the following structure:

Menu Item Description Parameters

Lock Level Sets the front panel interface lock 0, 1, 2, 3, or 4


level.
For information on each of the lock
levels, see D9859 Transcoder Lock
Levels.

OL-31980 -01 57
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Password Enter the password to successfully


set the current lock level.
Depending on the unit, the default
password for all lock levels is 1234.
For more information on the
default password, contact Cisco
customer support.

Old Pwd, New Pwd, To change the password, enter the


Confirm Pwd old password (Old Pwd). Next,
enter the new password (New
Pwd, four digits in the range from
0000 to 9999) and re-enter the new
password for confirmation
(Confirm Pwd). To change the
password, the receiver must be in
Lock Level 0. Depending on the
unit, the default password is 1234.
For more information on the
default password, contact Cisco
customer support.

Factory Reset Select this option to perform a Reboots Unit - you are
reset of receiver settings back to prompted to verify the
the factory set (default) values. A operation.
warning message prompts you to
Abort or Continue
confirm the operation.

Clear FWD tables Select to clear settings that are only Abort or Continue
used in older applications.
Reverting back to an older
application will revet to the default
values of the cleared settings. A
warning message prompts you to
confirm the operation.

Reboot Allows you to reboot the receiver. Select Continue to reboot the
You will be asked to confirm the receiver or Abort to cancel the
operation. operation.

KB Lock Select whether to lock the front Enabled or Disabled


panel keypad after a time of
disuse.

KB Lock Timeout If KB Lock is enabled, you can sets 5 to 1800 seconds. The default is
the keypad lock timeout period, in 60 seconds.
seconds. The keypad will lock after
the set period of disuse. Avoid
setting the period to a short
duration when the keypad is used
often.

58 OL-31980-01
Setup Menu

Menu Item Description Parameters

LCD Contrast Adjusts the contrast of the LCD 1 (lowest contrast) to 30 (highest
menu panel. contrast)

DL Mode Set the unforced over-the-air Always - Unforced download


download mode. will be accepted and saved in
memory.
Once - An unforced download
will be accepted, followed by a
reboot of the receiver, and the
DL Mode will change to Never.

Never - Unforced downloads


will not be accepted.
Note: Forced downloads
(initiated by the uplink) are
always accepted and always
result in a reboot of the receiver.
Service interruption will occur!

Limit Version Indicates the oldest version of the Read-only alphanumeric value
application that can be installed on
the current unit. Older
applications will not be installed.
DL Status Indicates the current download Init - Download component is
state. being initialized. You cannot
perform a download while in
this state.
Ready - Download component
is ready to receive downloads.

Buffer - Download in progress.


The CDTs are being received.
Program - The application is
being written to flash.
Swap - The IRD is swapping to
a new application and it will
reboot.
Shutdown - The IRD is shutting
down and it will reboot.
App Erase - An application is
being erased from the flash.
FPGA Erase - A Field
Programmable Gate Array
(FPGA) code is being erased
from the flash.

OL-31980 -01 59
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Type The type of download being None - No download is being


performed. performed.
HTTP - An HTTP download
from the web GUI is being
performed.
Over Air - An over-the-air
download is being performed.

Bank The type of code being App 5514 - Currently


downloaded. downloading code for app5514
on the main board.
App 7109 - Currently
downloading code for app7109
on the main board.
FPGA 7109 - Currently
downloading FPGA code to the
main board.
Note: The FPGA download
does not occur over-the-air.
App PPC - Currently
downloading code to the
application in the PowerPC on
the transcoder board.

PowerPC - Currently
downloading code (such as
FPGA) to the PowerPC on
the transcoder board.
CDT# Indicates the total number of Read-only numeric value.
expected code tables in the current
download.
Recv Displays the number of code tables Read-only numeric value.
received since the last completed
or aborted download, or power-
cycle.

Reject Displays the number of code tables Read-only numeric value.


rejected. Tables are rejected
whenever validation fails due to
things like CRC failure or incorrect
code or receiver type.

60 OL-31980-01
Setup Menu

Menu Item Description Parameters

Command Select a command to issue to the Abort - Stops a download that


current download. This command is currently being received.
is for over-the-air downloads only.
Restart - Restarts a previously
It has no effect on the HTTP
aborted download.
download.
Note: The download does not
resume from where it was
aborted, but restarts from the
beginning.
None - No action is to be
performed.

Date Format Select the date format. YYYY_MM_DD,


DD_MM_YYYY, or
MM_DD_YYYY

Time Format Select the time format. 24Hr, 24Hr SuspendZero, 12Hr,
12Hr SuspendZero. The
SuspendZero options omit the
leading zero.

GMT Off Select the local time zone offset +13:00, +12:00, +11:00, +10:00,
relative to the GMT time. The time +09:30, +09:00, +08:00, +07:00,
information in the transmitted +06:30, +06:00, +05:45, +05:30,
stream is broadcast as GMT time +05:00, +04:30, +04:00, +03:30,
and changing this setting will +03:00, +02:00, +01:00, GMT,
allow the unit to correctly display -01:00, -02:00, -03:30, -04:00,
the local time. -05:00, -06:00, -07:00, -08:00,
-09:00, -10:00, -11:00, -12:00

OL-31980 -01 61
Chapter 4 Front Panel Operation

Setup Menu: TS Input


To view the TS (Transport Stream) Input menu from the Main menu, press the
RIGHT arrow key once and then the SELECT key to reach the Setup menu. Then
press the RIGHT arrow key once and the SELECT key to view the TS Input menu.

For instructions on how to select and store settings, see About the Front Panel (on
page 34).

The TS Input menu has the following structure:

ASI Input

Menu Item Description Parameters

ASI Active Select whether to tune to the ASI input. Act or No


Note: Setting a new input to be active
will deactivate the currently active
input.

62 OL-31980-01
Setup Menu

Menu Item Description Parameters

Tune Mode Select the tables required for the service Basic - Requires NIT to be present.
list creation and signal acquisition.
Auto - Uses all the service list
tables and it will acquire if any
service list tables are present.
Custom - Uses the Custom Tuning
parameters, specified by the user.
The default is Basic.

CA Ctl Sets how the conditional access will Std - In standard mode, if a
attempt to descramble the scrambled program is not authorized, even if
programs. some services are not scrambled,
the whole program will not be
authorized.
Open - In open mode, if a program
is not authorized, services in the
program that are not scrambled
will still be available.

RF1, RF2, RF3, RF4 (RFx) Input

Menu Item Description Parameters

RFx Active (RF1, Select the input to be active. Act or No


RF2, RF3, RF4)
Note: Setting a new input to be active will
deactivate the currently active input.
Tune Mode Select which tables are required for the service Basic - Requires NIT to be
list creation and signal acquisition. present.
Note: When editing the tuning, the device is in Auto - Uses all the service
a transient state while acquiring tuning list tables and it will
information and channel lists, etc. The receiver acquire if any service list
reverts to the previous set of tuning tables are present.
settings/information and channels until these
Custom - Uses the Custom
changes are either saved or abandoned.
Tuning parameters,
specified by the user.
The default is Basic.

OL-31980 -01 63
Chapter 4 Front Panel Operation

Menu Item Description Parameters

CA Ctl Sets how the conditional access will attempt to Std - In standard mode, if
descramble the scrambled programs. a program is not
authorized, even if some
services are not scrambled,
the whole program will
not be authorized.
Open - In open mode, if a
program is not authorized,
any services in the
program that are not
scrambled will still be
available.

Select Sets the method used by the RF tuner to UserCfg - User


determine which input to use when switching configuration will only use
transports. the active RF input.
SW Map - Software map
uses the orbital position
settings from each input
and map it to those in the
NIT.

LO1 (GHz) Sets the lower oscillator frequency, in GHz, of 0.0 to 15.0 GHz. Must be
the LNB. In a single band oscillator, set its lower than the value for
frequency, in GHz. LO2.

LO2 (GHz) Sets the higher oscillator frequency, in GHz, of 0.0 to 15.0 GHz. Must be
the LNB. In a single band oscillator, set this higher than the value for
value to 0.0. LO1.

Crossover (GHz) This is the crossover frequency, which is an 0.0 to 15.0 GHz. In single-
internal threshold frequency used for selecting band LNB applications, set
the LO1 or LO2 frequency, depending on the this value to 0.0.
current Downlink frequency settings. This
option is only used in dual-band LNB
applications.
Satellite This is the name of the satellite currently When the satellite is not
selected. Choose the satellite you want to use listed, enter the known
to receive the signal from the list of satellites orbital position (OrbPos)
available. When you select a satellite, the of the satellite you want to
orbital position (OrbPos) is displayed. This is use to receive the signal.
important for automatic switching from one RF
input to another in the event of loss of the
signal, allowing the receiver to acquire an
alternate signal.

64 OL-31980-01
Setup Menu

Menu Item Description Parameters

OrbPos This is the location in orbit of the satellite Degrees


currently being used. The satellite position (in
degrees) in combination with the direction
(either E (East) or W (West)) denotes the
satellite position the dish connected to the
current RF Input should point to. This is used
when the satellite is not available in the look-
up menu list.
For manual configuration, enter the location of
the satellite using the numerical keypad. The
receiver will not recognize the satellite name
and identify it as Unknown. This setting is
required to resolve any ambiguity between RF
inputs during automatic disaster recovery.

E/W Denotes the satellite position the dish E, W or NA


connected to the current RF Input should point
to. This is used when the satellite is not
available in the look-up menu list.
Pol Marks the polarity of the signal connected to H (horizontal), Vert
this RF input. (vertical), A (Auto). Auto
is only applicable when
LNB Power is set to H-NIT
or V-NIT.

Validate Orbital This option validates the RF inputs to match


Position those expected by the network. The transcoder
will check to see if all the frequencies in the
Network Information Table (NIT) can be tuned
to.

Orbital Position This displays the last date that the ‘Validate N/A
Validation Date Orbital Position’ operation was performed.

Freq (GHz) This is the current Downlink operating 0.0 to 15.0 GHz
frequency used by the receiver for tuning the
received digital signal.

SymRate This is the symbol rate. The symbol rate must 1.0 to 45.0 Ms/s for DVB-
match that of the transmitted signal. S.
1.0 to 30.0 Ms/s for DVB-
S2 if Pilot Present is set to
Yes.
5.0 to 30.0 Ms/s for DVB-
S2 if Pilot Present is set to
No.

OL-31980 -01 65
Chapter 4 Front Panel Operation

Menu Item Description Parameters

FEC Select the Forward Error Correction inner code 1/2, 2/3, 3/4, 5/6, 7/8, or
rate. The FEC must match the FEC of the Auto
transmitted signal.
L-Band This is the L-Band operating frequency used by 950 to 2150 MHz
the receiver. This value is determined by the
values set in the Freq and LO options.

RF Lock Indicate whether the tuner has locked onto the Lock or NoLock
Radio Frequency signal with the current
settings.

Modulation Sets the modulation type for the received DVB-S or DVB-S2
signal.
Rolloff Sets the rolloff factor of the incoming signal. .20, .25, .35. Use .20 or .35
when DVB-S modulation
is used, and either of the
three when DVB-S2 is
used. Use a small number
to reject or filter carriers
close to the same
frequency.

InputIQ Select the Input signal spectrum inversion Auto, Normal, or


setting, which allows the operator to track and Opposite.
select inverted and non-inverted digital
Auto - The signal is
signals. This is normally used to automatically
tracked and inverted for
reject or filter out unwanted signals. correct selection, as
required.
Opposite - The signal is
always inverted.
Normal - The signal is not
inverted.

NetID Select the Network ID of the uplink signal the 1 to 65535. The default
receiver is to receive. The transcoder's Network value is 1.
ID must match the Network ID associated with
the transmitted signal.

LNB Power Set the power output of RF1 to the external Off, 13V, 18V, V-NIT, or
LNB. H-NIT.
V-NIT and H-NIT will use
vertical and horizontal
polarity until it is
automatically read from
the NIT.
Note: Power will not be
applied to the LNB when
set to Off.

66 OL-31980-01
Setup Menu

Menu Item Description Parameters

22kHz For dual band applications, select whether to On, Off, or Auto.
transmit the 22 kHz tone Local Oscillator
Auto uses the crossover
control signal of RF1. frequency to determine if
the tone is transmitted.

Tune Mode

Custom
This menu is where you set up your custom properties. Select the channel to set up
and then edit it.

Menu Item Description Parameters

Services List Mode If using custom tune mode, Rigorous - Requires all service list tables
select which tables are required to be present to acquire the signal.
for tuning.
Degraded - Requires any service list
table to be present to acquire the signal.

BAT This is not supported in the No


current release.

NIT If using custom tune mode, Yes or No


select whether to use the
Network Information Table
(NIT) when creating the service
list.
SDT If using custom tune mode, Yes or No
select whether to use the Service
Description Table (SDT) when
creating the service list.

PAT If using custom tune mode, Yes or No


select whether to use the
Program Association Table
when creating the service list.

Frequency Tuning If using custom tune mode, NIT - The transcoder can change tuning
select whether to use the NIT to parameters to use all transports available
tune to other transports, or to in the NIT.
force the tuning to user
User Cfg - The transcoder is forced to
configuration settings.
use the user selected tuning parameters.

OL-31980 -01 67
Chapter 4 Front Panel Operation

Status

Menu Item Description Parameters

Service List Mode Indicates if all the expected Degraded or Rigorous


service list tables are present
(Rigorous) or only some of the
service list tables are present
(Degraded)
BAT This is not supported in the No
current release.
NIT Indicates whether the Network Yes or No
Information Table (NIT) is being
used to create the service list.

SDT Indicates whether the Service Yes or No


Description Table (SDT) is being
used to create the service list.

PAT Indicates whether the Program Yes or No


Association Table (PAT) is being
used to create the service list.

Frequency Tuning Indicates whether tuning is NIT or User Cfg


using the NIT to tune to other
transports, or whether tuning is
forced to use the user selected
parameters.

Re-Acquire

Menu Item Description Parameters


Re-Acquire Re-acquires the signal using the Abort or Continue. Select Abort to
tuning parameters from user cancel the operation or choose Continue
settings. to complete the operation.

Setup Menu: IP
To view the IP menu from the Main menu, press the RIGHT arrow key once and
then the SELECT key to reach the Setup menu. Then, press the RIGHT arrow key
twice and the SELECT key to view the IP menu.

The IP menu allows you to set the parameters for communicating with other
equipment via the Ethernet Data and Management ports for MPEGoIP and MPE
applications and upgrading application software.

For instructions on how to select and store settings, see About the Front Panel (on
page 34).

68 OL-31980-01
Setup Menu

The IP menu has the following structure:

IP

Menu Item Description Parameters

Port ID Select the Ethernet interface to 1, 2, or 3. Interface 1 is the control and


configure. management interface and interface 2
and interface 3 are data interfaces.
Description Sets the description or name for the Up to 20 alphanumeric characters in
Ethernet interface. length.

V4/V6 Select the IP protocol. Only IPv4 is currently supported.

IP Address Sets the IPv4 IP address for the 12 digits in length (###.###.###.###)
interface.

Mask Sets the number of CIDR (Classless 8 to 30


Inter-Domain Routing) bits in the
network mask.

OL-31980 -01 69
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Gateway Sets the Network Gateway Address The IP Address/Mask and Gateway
on the Network, used to expose the Address should be changed together,
receiver to a WAN. i.e., as a group. The following table
shows the most commonly used
Subnet mask values to enter for a
chosen IP address mask, which will
depend on the size of your network.

Mask Subnet Mask

8 255.0.0.0

16 255.255.0.0

24 255.255.255.0

Phy Mode Set the speed and duplex type of the Auto (default), 1000FD (full duplex),
interface. Select Auto for PHY to 100HD (half duplex), 10FD, 100FD, or
negotiate speed and duplex with 10HD
other devices on the network, or
select 10 HD (half-duplex), 10 FD
(full-duplex), 100 HD, 100 FD, or 1000
FD to lock into a fixed mode.
MAC Address Displays the MAC address of the N/A
interface. It is set at the factory and is
a read-only value.

SNMP Read Only Sets the password to read data from a Up to 31 alphanumeric characters in
Community String device and to display diagnostics length. This string is case-sensitive.
traps/alarms.
The default community string is:
This is used when communicating public.
with a device within an SNMP
environment.

SNMP Read Write Sets the password to write data to a Up to 31 alphanumeric characters in
Community String device. length. This string is case-sensitive.
This is used when communicating The default community string is:
with a device within an SNMP public.
environment.

70 OL-31980-01
Setup Menu

Menu Item Description Parameters

Reset Credentials If for some reason, you cannot access


the decoder (due to a forgotten
password, corrupted data, etc.), the
recovery procedure for the decoder is
as follows:
Using the keypad, choose this field on
the front panel menu. A default login
username and randomly generated
password will be displayed on the
front panel display for approximately
30 seconds. The new account will
have Admin privileges. It is
recommended that this account be
replaced by a login
username/password chosen by the
administrator. To change the
username and password, you must be
an Admin user. Refer to Setting
Admin User Privileges via a Telnet
Connection (see "Setting Admin User
Privileges via a Telnet/SSH
Connection" on page 30).
Note: After this recovery procedure,
all existing user accounts will be lost.
Password Sets the password complexity for all No Checking, Minimal Checking, or
Complexity users. The complexity level changes Full Complexity Checking
will only affect the new user accounts
and password changes. It will not For more information, see the
Password Complexity table below.
affect existing accounts.

SNTP Server Sets the NTP server address. If the 12 digits in length (###.###.###.###)
NTP server address is not set (0.0.0.0),
the IRD will not attempt to connect to
the server.

SNTP Enable Periodically request NTP timestamps Yes or No


from the NTP server and to
synchronize its system (i.e., non-DVB
related) time with the NTP server.

Passw ord Complex ity

Password Complexity Description

No Checking There are no restrictions on passwords.


Note: A minimum of one character is required.

OL-31980 -01 71
Chapter 4 Front Panel Operation

Password Complexity Description

Minimal Checking The passwords must comply with the following requirements:

 It cannot contain username or reversed username.

 It cannot contain any of the following strings: cisco, sciatl, ocsic,


Itaics, atlsci, icslta, or any string achieved by full or partial
capitalization of letters.

 No letter is repeated more than three times in a row.

 Must contain a minimum of four characters.


Full Complexity Checking The passwords must comply with the following requirements:

 It cannot contain username or reversed username.

 It cannot contain any of the following strings: cisco, sciatl, ocsic,


Itaics, atlsci, icslta,or any string achieved by full or partial
capitalization of letters.

 No letter is repeated more than three times in a row.

 Must contain a minimum of eight characters.

 Must contain a minimum of three of the following types of


characters: capital letters, small letters, digits, and special
characters.

Traps

Menu Item Description Parameters

Trap IP Address Sets the destination IP address for SNMP Up to 12 digits in length, e.g.,
trap messages for system events (i.e., fault 155.128.100.200
messages).
Ins, Del You can choose to Insert or Delete entries.
Up to 25 entries can be assigned to the Trap
IP Address and Community String fields.
To add a new entry, press Ins and enter the
new entry in the IP Address or Community
String field. To delete an existing entry,
scroll to the IP address or community string
you want to delete and press Del.

Trap Community Sets the Community string for the Trap IP Public or custom string. Up to
String Address. 35 characters. The default is:
public.

72 OL-31980-01
Setup Menu

Protocols
The Protocols menu allows you to control remote access protocols (Telnet, SSH, HTTP, and
SNMP) to the IRD.

Menu Item Description Port Number Parameters

Telnet Controls Telnet access to the TCP port #23 Enable (default) - Allow
IRD. Telnet connections.
Disable - Disables the listener
for the Telnet port.

SSH Controls SSH access to the IRD. TCP port #22 Enable (default) - Allow
secure shell connections.
Disable - Disables the listener
for the SSH port.

HTTP Controls HTTP access to the TCP port #80 Disable - Disables the listener
IRD. for HTTP. for the HTTP port.
TCP port #443 Enable (default) - Allow web
for HTTPS. connections.
Secure - Encrypted access to
the webserver (HTTPS). For
more information, see
Protocol Control Settings (on
page 221).
SNMP Controls SNMP access to the UDP port Enable (default) - Allow
IRD. #161 SNMP connections.
Disable - Disables the listener
for the SNMP port.

MPE Sets whether the MPE data is N/A Fwd None - The MPE data is
forwarded to the network. not forwarded to the
Note: The transcoder supports network.
up to a maximum of 10 Mbps Fwd All - All the MPE data is
throughput when forwarding forwarded to the network.
1500 byte packets.
Fwd Filtered - Only the MPE
data from the defined Static
Multicast Filtering table is
forwarded to the network.
For more information on
configuring the Static
Multicast Filtering table, see
To Add a Static Multicast
Filtering (on page 227).

OL-31980 -01 73
Chapter 4 Front Panel Operation

Menu Item Description Port Number Parameters

Syslog Select the logging protocol to Default port Syslog TCP, Disable, Legacy,
use. The Legacy option is used #514 for TCP Syslog UDP
by Cisco customer support only. and UDP
It is highly recommended that
you use the following syslog
servers:
Syslog-ng - Balabit for Linux
Syslog Watcher - SnmpSoft for
Windows
For more information, see
System Logs (on page 222).

Syslog Server If Syslog TCP or Syslog UDP is N/A 12 digits in length


selected as the Syslog, set the IP (###.###.###.###)
address of the server.

Port This sets the TCP or UDP port N/A 1 to 65535


number of the server.

By enabling or disabling the protocols, dynamic hardware and software firewalls are
created for the D9859 transcoder.

Accessing TCP and UDP Serv ices


The following describes the commands used to access port information for all the supported
protocols. The examples of TCP-based services are: Telnet, SSH, and HTTP. The examples of
UDP-based services are: SNTP and SNMP.
Proceed as follows to obtain TCP or UDP information:
1 Start a new communication session with the receiver using a utility, such as Tera
Term Pro or PuTTY. For more information on starting a new connection, see
Starting a Telnet/SSH Session (on page 30).

74 OL-31980-01
Setup Menu

2 In the admin command prompt, type ipal tcp_list for a list of TCP connections
or ipal udp_list for a list of UDP connections and press Enter. The following is
an example of the results:

3 All other connections that are not specifically requested by remote access
protocol selection or triggered by user actions, such as an FTP transfer, do not
have active listeners and the corresponding TCP/UDP ports are closed. To
strengthen security, the hardware firewall drops all incoming packets for the
closed ports.
Note: The hardware firewall may impose different rules for the Management
and Data ports. For example, remote access protocols, such as SSH or HTTP, are
only enabled on the Management port.

Redundancy
The D9859 transcoder is a single-port unit. The redundancy settings are not
supported.

OL-31980 -01 75
Chapter 4 Front Panel Operation

Setup Menu: Services


To view the Services menu from the Main menu, press the RIGHT arrow key once
and then the SELECT key to reach the Setup menu. Then press the RIGHT arrow
key three times and the SELECT key to view the Services menu.

The Services menu allows you to set up all the operating parameters associated with
audio, video and captions services.

Each parameter is described below. The menu has the following structure:

76 OL-31980-01
Setup Menu

Video

Menu Item Description Parameters

PV Format Sets the primary video output format for Auto, SD, HD 720p, or HD
local decoding. 1080i

Stream Indicates the video format of the input


video stream. This value is read-only.

SD Format Selects the standard definition output Auto, NTSC, PAL-N (AR),
format to use on the primary video if the PAL-M or PAL-B/G/I/D. Use
PV Output is set to SD. NTSC for 525-line systems and
PAL-B/G/I/D for 625-line
systems.

SD Output Indicates the actual standard definition NTSC, PAL-N (AR), PAL-M or
format of the primary video output if the PAL-B/G/I/D
PV Output is set to SD.

Bitrate Indicates the bit rate of the input video 1.0 to 15.0 Mbps
stream, in Mbps.

Alarm Video Cutoff Sets whether the video output is cut off if Enable or Disable.
any enabled alarm is active on the receiver.
The default is Disable.
When video is cut off, there will be no
horizontal or vertical synchronization on
the output. This is useful for downstream
redundancy switching by detecting a loss
of video signal.
Note: This same function also exists under
Setup: Alarm/Warning.
OSD Messages Sets whether alarms and warnings are to Enable or Disable
be displayed on the on-screen display (e.g.,
TV monitor).

TV A/R Select the standard definition aspect ratio 4:3 or 16:9


of your TV monitor.

Convert Select the conversion method that the None, Auto, Auto AFD, 16:9
receiver will perform on the incoming L/B, 4:3 P/B, 14:9, 4:3 CCO,
signal for the picture to be displayed 16:9 SCALE. The default is
correctly on your TV based on the TV A/R Auto. For more information, see
setting. Aspect Ratio Conversions (on
page 78).
Stream Indicates the aspect ratio of the incoming 4:3 or 16:9
video stream. This is read-only.

OL-31980 -01 77
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Act Conv The actual aspect ratio conversion the None, 16:9 L/B, 4:3 P/B, 14:9,
receiver will perform based on what you 4:3 CCO, 16:9 SCALE
have selected. This is read-only.
Refer to the Aspect Ratio Conversions
table below for the conversions performed
by the receiver based on your selection,
and the effect on the picture displayed by
the receiver in each case (without Auto
AFD)

WSS Mode Select the Wide Screen Signaling output Auto:Create - Creates WSS to
mode. It is used to select how the receiver output the correct aspect ratio
affects PAL WSS when it is present in the when performing aspect ratio
VBI line 23. conversion.
Auto:Modify - If WSS is present
in the input stream, it is
modified to output the correct
aspect ratio when performing
aspect ratio conversion. If WSS
is not present in the input, no
WSS will be present in the
output.
Suppress - Removes WSS
output.
Passthrough - Passes WSS
unmodified as received by the
receiver.
The default is Passthrough.

WSS Status This indicates the current output value of 4:3 F/F, 16:9 L/B CEN, 16:9
PAL WSS in VBI line 23. L/B TOP, >16:9 L/B, 14:9 L/B
CEN, 14:9 L/B TOP, 14:9 F/F
CEN, 16:9 F/F, or UNDEFINED
Note: F/F is full format, and
L/B is letter box.

78 OL-31980-01
Setup Menu

Aspect Ratio Conv ersions


The following table displays the conversions performed by the receiver based on the
Act Conv selection:

Stream TV A/R Conversion Act Conv Description Image

4:3 4:3 None None Normal Picture

4:3 4:3 Auto None No conversion

4:3 4:3 16:9 L/B None Conversion is not


possible. Normal
picture.

4:3 4:3 4:3 CCO None Conversion is not


possible. Normal
picture.
4:3 4:3 4:3 P/B None Conversion is not
possible. Normal
picture.

4:3 4:3 14:9 None Conversion is not


possible. Normal
picture.

4:3 4:3 16:9 SCALE None Conversion is not


possible. Normal
picture.

4:3 16:9 None None Picture is short and


wide.

4:3 16:9 Auto 4:3 P/B Uses 4:3 P/B.

4:3 16:9 16:9 L/B None Conversion is not


possible. Picture appears
short and wide.
4:3 16:9 4:3 CCO None Conversion is not
possible. Picture appears
short and wide.

OL-31980 -01 79
Chapter 4 Front Panel Operation

Stream TV A/R Conversion Act Conv Description Image

4:3 16:9 4:3 P/B 4:3 P/B 4:3 picture is centered in


a pillar-style box.

4:3 16:9 14:9 14:9 Compromises some up-


sampling. Some black
bars and cropping are
visible.

4:3 16:9 16:9 SCALE 16:9 Vertically up-samples


SCALE the center of the 4:3
picture and crops the
top and bottom of the
screen.

16:9 16:9 None None Normal

16:9 16:9 Auto None No conversion. Normal


picture.

16:9 16:9 16:9 L/B None Conversion is not


possible. Normal
picture.

16:9 16:9 4:3 CCO None Conversion is not


possible. Normal
picture.

16:9 16:9 4:3 P/B None Conversion is not


possible. Normal
picture.

16:9 16:9 14:9 None Conversion is not


possible. Normal
picture.

16:9 16:9 16:9 SCALE None Conversion is not


possible. Normal
picture.

16:9 4:3 None None Picture appears tall and


thin.

80 OL-31980-01
Setup Menu

Stream TV A/R Conversion Act Conv Description Image

16:9 4:3 16:9 L/B 16:9 L/B Vertically down-samples


the picture and applies
black bars at the top and
bottom of the screen.

16:9 4:3 4:3 CCO 4:3 CCO Horizontally up-samples


the center portion of the
picture to fill the screen.

16:9 4:3 4:3 P/B None Conversion is not


possible. Picture appears
tall and thin.

16:9 4:3 14:9 14:9 Compromises some up-


sampling. Some black
bars and some cropping
are visible.

16:9 4:3 16:9 SCALE None Conversion is not


possible. Picture appears
tall and thin.

Note: Active Format Descriptor (AFD) - normally it is necessary to set both the TV
Aspect Ratio and Conversion to correctly display the video program on the TV
system. The Auto AFD option enables the receiver output to automatically match the
display format of the video program to the TV system based on specific (uplink)
program information carried in the transport stream. In this case, the receiver
performs the conversion based on the TV Aspect Ratio setting combined with the
program-specific uplink information to provide the “best fit” for display of the
program material on the TV. This feature is primarily used in 16:9 and 14:9 (wide
screen) applications.

Audio

Menu Item Description Parameters

Aud# Sets which balanced audio output 1 or 2


on the rear panel to configure.

OL-31980 -01 81
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Stereo/Mono Sets the output mixing. Stereo - Left and Right are passed
directly through to Left and Right
R-MONO - Right is passed to both the
Left and Right
L-MONO - Left is passed to both the
Left and Right
Mixed - Left is passed to both the Left
and Right, and Right is passed to both
the Left and Right.

AC3 Compression Sets the AC3 compression mode to Line Mode, Custom 1, Custom 0 or
use if the output is compressed RF Mode.
Dolby Digital audio.
RF Mode is recommended for analog
cable modulators.

Left (dB) Sets the volume adjustment for the -6.0 to +6.0
Left audio channel, in dB.
Any value can be entered with the
numeric keypad (in the appropriate
range), but the UP and DOWN
arrows will increase or decrease in 0.5
dB steps.
Right (dB) Sets the volume adjustment for the -6.0 to +6.0
Right audio channel, in dB.
Any value can be entered with the
numeric keypad (in the appropriate
range), but the UP and DOWN
arrows will increase or decrease in 0.5
dB steps.

Select Language By Method of selecting the audio PID PMT Order, Language List, Language
for the local audio decoding. This is Entry
required if the monitored program
PMT Order (default) - Allows you to
contains more than two audio PIDs.
select a PMT order.
Language List - Allows you to select a
language from the available list.
Language Entry - Allows you to enter
a language code.

82 OL-31980-01
Setup Menu

Menu Item Description Parameters

Language List If Select Language By is set to ara (Arabic), btk (Batak (Indonesia),
Language List, select the language ben (Bengali), bul (Bulgarian), chi
for the selected audio. (Chinese), cze (Czech), dan (Danish),
dut (Dutch), eng (English), fin
(Finnish), fre (French), ger (German),
gre (Greek), heb (Hebrew), hin
(Hindi), hun (Hungarian), ice
(Icelandic), ind (Indonesian), ita
(Italian), jpn (Japanese), kor (Korean),
may (Malay), mul (Multiple
Languages), nor (Norwegian), per
(Persian), pol (Polish), por
(Portuguese), rum (Romanian), rus
(Russian), san (Sanskrit), scc
(Serbian), sin (Sinhalese), slo (Slovak),
som (Somali), spa (Spanish), swe
(Swedish), tai (Tai Other), tam
(Tamil), tha (Thai), tur (Turkish), ukr
(Ukrainian), or vie (Vietnamese)

PMT Src Selects the PMT source for the None, AUDI to AUD64
audio channel.

Entry If Select Language By is set to Enter a three-character code provided


Language Entry, select the by your uplink service provider
language entry for the selected under Entry using the numeric
audio. keypad (e.g., eng for English).
The supported languages are
according to ISO 639-2 Language
Codes.

Captions

Menu Item Description Parameters

Preferred Mode Selects the type of closed captioning Auto, SA Custom, EIA 708,
to use if there are multiple available Type 3, Type 4 SA, DVS 053
in the stream. Type 4 ATSC, Reserved or
DVS 157. The default is Auto.
Note: SA Custom is not
supported when telecine video
coding is enabled.
Actual Output Indicates the actual closed caption Auto, SA Custom, EIA 708,
mode in the output. This is read- Type 3, Type 4 SA, Type 4
only. ATSC, Reserved, or DVS 157

OL-31980 -01 83
Chapter 4 Front Panel Operation

VBI

WSS

Menu Item Description Parameters

WSS Mode Selects the Wide Screen Signaling Auto:Create - Creates WSS to
output mode. It is used to select output the correct aspect ratio,
how the receiver affects PAL WSS when performing aspect ratio
when it is present in the VBI line 23. conversion.
Auto:Modify - If WSS is
present in the input stream, it
is modified to output the
correct aspect ratio when
performing aspect ratio
conversion. If WSS is not
present in the input, no WSS
will be present in the output.
Suppress - Removes WSS
output.
Passthrough - Passes WSS
unmodified as received by the
receiver.
The default is Passthrough.

WSS Stat Indicates the current output value 4:3 F/F, 16:9 L/B CEN, 16:9
of PAL WSS in VBI line 23. L/B TOP, >16:9 L/B, 14:9 L/B
CEN, 14:9 L/B TOP, 14:9 F/F
CEN, 16:9 F/F, or
UNDEFINED
Note: F/F is full format, and
L/B is letter box.

VITC
This is not supported in the current release.

VITS

Menu Item Description Parameters


VITS PAL Line 17, Select whether to enable or disable Enable or Disable
18, 330, 331 Vertical Interval Test Signal on PAL
Lines 17, 18, 330, or 331.

84 OL-31980-01
Setup Menu

Subtitles
This menu allows you to configure the type of subtitling (i. e., DVB or Imitext) displayed by
the transcoder, and how the transcoder displays subtitling on the TV.

Menu Item Description Parameters

Op Mode Sets the subtitle mode. Off - No subtitles are displayed.


On - Displays DVB or Imitext subtitles, if
available.
DVB - Displays only DVB titles, if
available. Otherwise, no subtitles are
displayed.
Imitext - Displays only Imitext subtitles,
if available. Otherwise, no subtitles are
displayed.

Select Language By Select the input source for Language List - Allows you to select a
the subtitle language. language from the available list.
Language Entry - Allows you to enter a
language code.
PMT Order - Allows you to select a PMT
order.

The default setting is Language List.


Language Entry and PMT Order are
more applicable for advanced
applications.
Language List If Language List was ara (Arabic), btk (Batak (Indonesia), ben
selected in the Select (Bengali), bul (Bulgarian), chi (Chinese),
Language By menu, select cze (Czech), dan (Danish), dut (Dutch),
the MPEG language to eng (English), fin (Finnish), fre (French),
display. ger (German), gre (Greek), heb
(Hebrew), hin (Hindi), hun (Hungarian),
ice (Icelandic), ind (Indonesian), ita
(Italian), jpn (Japanese), kor (Korean),
may (Malay), mul (Multiple Languages),
nor (Norwegian), per (Persian), pol
(Polish), por (Portuguese), rum
(Romanian), rus (Russian), san
(Sanskrit), scc (Serbian), sin (Sinhalese),
slo (Slovak), som (Somali), spa (Spanish),
swe (Swedish), tai (Tai Other), tam
(Tamil), tha (Thai), tur (Turkish), ukr
(Ukrainian), or vie (Vietnamese)

OL-31980 -01 85
Chapter 4 Front Panel Operation

Menu Item Description Parameters

PMT Order If PMT Order was selected First to Eighth


in the Select Language By
menu, select the subtitle PID
entry to display. This
information is available from
your uplink service
provider.

Entry If Language Entry was Enter the three-character code provided


selected in the Select by your uplink service provider under
Language By menu, select Entry using the numeric keypad (e.g.,
the subtitle PID entry to eng for English).
display. The information is
The supported languages are according
available from your uplink
to ISO 639-2 Language Codes.
service provider.

Imitext Position Sets the position of the on- Standard or Extended


screen subtitle text.

ForeGnd Sets the text color for Imitext Auto, Yellow, or White.
subtitles.
Auto displays text in the color
transmitted by the subtitling equipment.
Yellow and White override the color set
by the uplink, and display text in the
selected color.

BackGnd Sets the text background for Auto - Uses the uplink subtitling
Imitext subtitles. equipment setting.
Shadow - Applies an outline to the right
side of each text character. No
background box is applied to subtitles,
i.e., text is visible directly on top of
video.
Opaque - Applies a black box to each
text character.
Semi - Applies a semi-transparent box to
subtitle text.
None - No shadow or outline is applied
to subtitle text.

86 OL-31980-01
Setup Menu

Decode

Menu Item Description Parameters

Decoder Select the local decode service to Video, Audio1 to Audio4, VBI
configure. (Vertical Blanking Interval)
DATA (low speed data), MPE1
Note: By default, all the decode
to MPE5 (Multiprotocol
services are enabled.
Encapsulation), STT
(Subtitles), or DPI (Digital
Program Insertion)
Enabled Select whether the local decoding of Yes or No
this service is enabled or disabled.

OL-31980 -01 87
Chapter 4 Front Panel Operation

Setup Menu: Outputs


To view the Outputs menus from the Main menu, press the RIGHT arrow key once
and then the SELECT key to reach the Setup menu. Then press the RIGHT arrow
key four times and the SELECT key to view the Outputs menu.

The Outputs menu allows you to set up the rear panel control relays for alarms, cue
tones and cue triggers, and the transport stream outputs, Digital Program Mapping
(DPM), and Transcoding.
For instructions on how to select and store settings, see About the Front Panel (on
page 34).
The Outputs menu has the following structure:

88 OL-31980-01
Setup Menu

Cueing

Menu Item Description Parameters

Cueing Mode Select whether cueing output Trigger or Tone


should be DTMF tones or
Tone - Cue tones are standard Dual-
trigger pins.
Tone Multi-Frequency (DTMF) tones.
The tones are generated at the Cue
Tone/Relay output on the rear panel
of the receiver.
Trigger - Cue trigger refers to open-
collector pins which can be toggled at
the Cue Tone/Relay output on the
rear panel of the receiver.

Trigger Polarity If the Cueing Mode was set to High or Low


Trigger, select the pin polarity.
High - Pins act as open or floating
collectors on an active cueing signal
and as ground on an inactive signal.
Low - Pins act as ground on an active
cueing signal and as open or floating
collectors on an inactive signal.

Repeat If the Cueing Mode was set to 1, 2, or 3. The default is 3.


Tone, set the number of
consecutive tone sequences to
be generated. Values greater
than 1 are provided when a
scenario demands repetition to
ensure that the ad insertion
equipment receives the signal.
Tone (ms) If the Cueing Mode was set to 0 to 80. The default is 40.
Tone, set the duration of each
tone, in milliseconds.

Silence (ms) If the Cueing Mode was set to 0 to 80. The default is 40.
Tone, set the duration, in
milliseconds, of each silence
between tones.
Seq# Select the tone sequence to 1 to 16
configure.

State Select whether the current tone Enabled or Disabled. When disabled,
sequence is enabled or disabled. no cue tone is output.

OL-31980 -01 89
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Tones Sets the three digit tone 000 to 999


sequence.
Mode Sets the tone sequence mode. * - Start tone only

# - End tone only


*/# - Start and end tones. The end
tone is signaled after waiting the time
specified in Delay(sec).

Delay(sec) If the Mode was set to */# 1 to 255. The default is 30.
(Start/Stop), set the delay, in
seconds, between the start and
stop sequences.

Relay Mode The relay can be programmed Alarm or Trigger


to respond to an alarm or
The following table displays the
warning state, or the state of
possible field settings and their
one of the eight cue trigger
relationship to the receiver output:
pins. The response is generated
at the Cue Tone/Relay output
on the rear panel of the Relay Condition Relay
Mode Contact
receiver.

NC- C-No
C

Alarm Unit Power Open Close


Off
Alarm State Open Close

No Alarm Close Open

Trigger Active Close Open


(selected in
PNC)

Inactive Open Close

Cue Trigger Bit If the Relay Mode is set to 1 to 8


Trigger, select the cue trigger
bit/pin that will activate the
relay.

Cue Tone Test Sets the three digit cueing tone 000 to 999
test sequence.

Mode Sets the test sequence mode. * - Start tone


# - End tone

Run Test Select and press continue to run


the cue tone test according to
the Cue Tone Test and Mode.

90 OL-31980-01
Setup Menu

TS Out - ASI

Menu Item Description Parameters

Name Displays the name assigned to the 20-character string


transport output for ease of
reference. This is read-only.

Rate Control Select the output rate control. Auto - The output rate follows that set by the
uplink. This setting can be used if the signal
source is ASI. If Insert Null Packet is set to Yes,
the output bit rate is the same as the input rate
(including all the null packets). If Insert Null
Packet is set to No, the output rate is equal to the
payload rate of the transport stream to be
encapsulated, and in most cases, it will be lower
than the overall input rate.
User - The output rate is specified by the User
Rate(Mbps) parameter. It is determined by the
user setting regardless of the input source. Null
packets are always inserted when the configured
output bit rate is higher than the payload rate of
the transport stream to be encapsulated.
User If the Rate Control is set to User, 0 to 206 Mbps
Rate(Mbps) set the maximum output bit rate.
Note: Output data may be lost if this bit rate is set
If null packets are inserted, this
to a value less than the actual signal bit rate.
will be the output rate.
This setting is used when the
signal source is RF or ASI and
allows you to set the output bit
rate to a value expected by
equipment connected to the ASI
output.

OL-31980 -01 91
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Output Mode Select the DPM output mode for No Output - No ASI output will be generated and
the current output. the ASI port will be disabled.
With the exception of No Output Passthrough - All PEs will be set to Pass and other
and Full DPM Control, selecting DPM settings will also be set.
a mode will configure the DPM
Service Chans Only - This is similar to
settings to achieve the specified
Passthrough, except that only channels applied to
behavior. In this way, they act as
program entries are available on the output.
DPM presets.
MAP Passthrough - The output will be identical to
The Config Type is changed from
the input, except that channels assigned to PEs
Unmodified to Edited by User.
and PIDs will be mapped using the DPM settings.
It is highly recommended to use If the input is tuned to a valid channel, the PEs are
either one of these basic modes, automatically set to Map. Otherwise, the PEs are
or, for advanced setup, enter the automatically set to Drop. When selecting MAP
DPM mapping before setting the Passthrough, the option to re-sync will be
Output Mode. provided. If you select Yes, it will set the DPM
mapping to the last valid (or saved) configuration.
If you select No, it will use the existing DPM
maps. If the PE is mapped, it uses the last saved
output MAP configuration. The output map (for
example, output channel PMT) does not change
automatically if the input or channel number is
changed.
MAP Svc Chans Only - This is similar to MAP
Passthrough, except that only channels applied to
program entries are available on the output. If the
input is tuned to a valid channel, the PEs are
automatically set to Map. Otherwise, the PEs are
automatically set to Drop. When selecting MAP
Svc Chans Only, the option to re-sync will be
provided. If you select Yes, it will set the DPM
mapping to match the current input. If you select
No, it will use the existing DPM maps. If the pE is
mapped, it uses the last valid input. The output
map (for example, output channel PMT) does not
change automatically if the input or channel
number is changed.
Full DPM Control - The output will be generated
according to the DPM settings. This is a manual
control setting.
Transcoding - The output will be generated using
the DPM MAP settings, except that the DPM
action (Act) will be set to Xcode and the
Descramble Mode will be set to Descrambled.

92 OL-31980-01
Setup Menu

Menu Item Description Parameters

Config Type Indicates the current DPM Edited by User - DPM changes were made.
configuration change by a user
Unmodified - No changes were made after setting
after changing the Output Mode.
a new Output Mode.
Auto Re-Mapped - Output map changed
automatically to fix the output channel or PID
conflicts at the time of setup.
Changed by Uplink - DPM output changes were
initiated by an encoder.
Descramble Select whether the output will be Scrambled - The output channel will remain
Mode descrambled if the input is scrambled even if the PE is authorized and can
scrambled. descramble the channel.
Descrambled - Descrambles the output channel,
and passes in-the-clear channels.
The default is Descrambled.

Insert Null Select whether to insert null Yes or No


Packet packets into the output to
Note: It is recommended that the Insert Null
maintain output at a constant bit
Packet is set to Yes, especially if the Output Mode
rate.
is set to Transcoding.

Auto Map Sets whether the DPM resolves Yes or No


the channel and PID collisions
automatically on the transport
outputs. New values are assigned
to the parameters that caused the
conflict. The new assigned values
are not used by any incoming
transport or other PE outputs. If a
collision is detected, you can
review the new changes before
applying the new changes.

Auto Map Select whether the DPM sets the Yes or No


Aux output actions for all the auxiliary
PEs to Map when the Output
Mode is set to Transcode. If the
Fixed Output is set to Yes, the
output configuration for the
auxiliary PEs is determined by
the fixed output table options
when you resynchronize the
output channels and PIDs to
match the input programs.
Note: The DPM resolves any
output conflicts automatically,
even if the Auto Map is set to No.

OL-31980 -01 93
Chapter 4 Front Panel Operation

MOIP

Menu Item Description Parameters


Name This is the name assigned to the 20-character string
transport output for ease of
reference.

Rate Control This is the DPM output rate Auto - The output rate follows that set by the
control. uplink. This setting can be used if the signal
source is ASI. If Insert Null Packet is set to
Yes, the output bit rate is the same as the input
rate (including all the null packets). If Insert
Null Packet is set to No, the output rate is
equal to the payload rate of the transport
stream to be encapsulated, and in most cases,
it will be lower than the overall input rate.
User - The output rate is specified by the User
Rate parameter. It is determined by the user
setting regardless of the input source. Null
packets are always inserted when the
configured output bit rate is higher than the
payload rate of the transport stream to be
encapsulated.

94 OL-31980-01
Setup Menu

Menu Item Description Parameters

Output Mode Select the DPM output mode No Output - No MPEGoIP output will be
for the current output. generated.
With the exception of No Passthrough - All PEs will be set to Pass and
Output and Full DPM Control, other DPM settings will also be set.
selecting a mode will configure
Service Chans Only - This is similar to
the DPM settings to achieve the
Passthrough, except that only channels
specified behavior. In this way,
applied to program entries are available on the
they act as DPM presets.
output.
The Config Type is changed
MAP Passthrough - The output will be
from Unmodified to Edited by
identical to the input, except that channels
User.
assigned to PEs and PIDs will be mapped
It is highly recommended to using the DPM settings. If the input is tuned to
use either one of these basic a valid channel, the PEs are automatically set
modes, or, for advanced setup, to Map. Otherwise, the PEs are automatically
enter the DPM mapping before set to Drop. When selecting MAP Passthrough,
setting the Output Mode. the option to re-sync will be provided. If you
select Yes, it will set the DPM mapping to the
last valid (or saved) configuration. If you select
No, it will use the existing DPM maps. If the
PE is mapped, it uses the last saved output
MAP configuration. The output map (for
example, output channel PMT) does not
change automatically if the input or channel
number is changed.
MAP Svc Chans Only - This is similar to MAP
Passthrough, except that only channels
applied to program entries are available on the
output. If the input is tuned to a valid channel,
the PEs are automatically set to Map.
Otherwise, the PEs are automatically set to
Drop. When selecting MAP Svc Chans Only,
the option to re-sync will be provided. If you
select Yes, it will set the DPM mapping to
match the current input. If you select No, it
will use the existing DPM maps. If the PE is
mapped, it uses the last valid input. The
output map (for example, output channel
PMT) does not change automatically if the
input or channel number is changed.
Full DPM Control - The output will be
generated according to the DPM setting.
Transcoding - The output will be generated
using the DPM MAP settings, except that the
DPM action (Act) will be set to Xcode and the
Descramble Mode will be set to Descrambled.

OL-31980 -01 95
Chapter 4 Front Panel Operation

Menu Item Description Parameters

Config Type Indicates the current DPM Edited by User - DPM changes were made.
configuration change by a user
Unmodified - No changes were made after
after changing the Output
setting a new Output Mode.
Mode.
Auto Re-Mapped - Output map changed
automatically to fix the output channel or PID
conflicts at the time of setup.
Changed by Uplink - DPM output changes
were initiated by an encoder.

Insert Null Packet This parameter selects whether Yes or No


to insert null packets in the
output stream.
Null packets are always
inserted if the Rate Control is
set to User.

Descramble Mode This parameter selects whether The default mode is Descrambled.
the receiver should scramble
Scrambled - Scrambles the output channel
the output even if it is
even if the PE is authorized and can
authorized to receive the
descramble the channel.
channel.
Descrambled - Descrambles the output
channel, and passes in-the-clear channels.

Auto Map Sets whether the DPM resolves Yes or No


the channel and PID collisions
automatically on the transport
outputs. New values are
assigned to the parameters that
caused the conflict. The new
assigned values are not used by
any incoming transport or other
PE outputs. If a collision is
detected, you can review the
new changes before applying
the new changes.

96 OL-31980-01
Setup Menu

Menu Item Description Parameters

Auto Map Aux Select whether the DPM sets the Yes or No
output actions for all the
auxiliary PEs to Map when the
Output Mode is set to
Transcode. If the Fixed Output
is set to Yes, the output
configuration for the auxiliary
PEs is determined by the fixed
output table options when you
resynchronize the output
channels and PIDs to match the
input programs.
Note: The DPM resolves any
output conflicts automatically,
even if the Auto Map is set to
No.

MOIP Streams

Menu Item Description Parameters

User Rate (Mbps) This parameter controls the 0 to 206 Mbps


output rate when Rate Control
is set to User.
Note: Output data will be
partially or completely lost if
the user-selected bit rate is set
to a value that is less than the
actual signal bit rate.
Intf Mode This selects the MPEG over IP None - Disables the MPEG over IP
output mode. interface.

Data Port - Always output data on the


Data port.
Control Port - Always output data on
the Management port.

TS/IP This selects the maximum 1 to 7


number of transport packets
per IP packet.
PCR@IP Start This selects whether to always Yes or No
transmit a new IP packet when
a new Program Clock Reference
(PCR) arrives.

OL-31980 -01 97
Chapter 4 Front Panel Operation

Menu Item Description Parameters

MOIP Selects the transport protocol to RTP or UDP


be used for the output stream.
Min IP/s This selects the minimum 0, 2 to 1000
number of IP packets per
second.

TOS (Type Of This sets the quality of service. 0 to 255


Service)

TTL (Time To Live) This sets the hop limit of the 0 to 255
packet's lifespan.

DestAddr Enter the unicast (valid host IP Unicast: valid host IP


only) or multicast destination
Multicast: IP in range of 224.0.0.0 to
IP address.
239.255.255.255
Note: It is not recommended to use
multicast IP addresses reserved by
the Internet Assigned Numbers
Authority (IANA).

UDPPort This selects the destination port 1 to 65534


number.
Note: If you selected RTP for MOIP,
you must select an even destination
port number.
Note: It is not recommended to use
destination UDP ports reserved by
the IANA.
SrcPort This selects the source UDP 0 to 65535
port number.
Note: Set the SrcPort to 0 to use the
default source UDP port (49162).

Send SAP This selects whether to send None or RFC2327


Session Announcement
Protocol messages.
SAP Multicast This is the IP address where the It is not recommended to change the
Address SAP announcements are sent, if default IP address (224.2.127.54).
required.

SAP Port This is the UDP port where the 1 to 65534


SAP announcements are sent, if
Note: It is not recommended to
required.
change the default SAP port 9875.
SAP ID Describes the SAP output User String or SDT Channel
stream name source.

SAP User Str Provides the SAP user string. Up to 31 characters

98 OL-31980-01
Setup Menu

TS Out - DPM
To view the DPM menu from the TS Out menu, press the RIGHT arrow key. The
DPM menu provides access to functionality associated with Global, ASI, and MOIP
outputs.
The DPM menu allows you to groom functionality on a program basis where
individual service PID modifications are provided on a limited scale.
Use the digital program mapping features to:
 configure the transport output bit rate

 configure the output mode for a program entry

 configure the service and PID output settings in a program entry


Note: Any changes made to the ASI/MOIP DPM values will automatically change
the Config Type to Edited by User.

The DPM menu has the following structure:

OL-31980 -01 99
Chapter 4 Front Panel Operation

DPM - Global

Menu Item Description Parameters

Resync All: Select to resynchronize all DPM ASI


output with the PMT data for
all program entries on the
selected output.

Regenerate Selects whether to regenerate Always or As Needed


the PSI tables in the output.
Always - All tables are regenerated.
As Needed - Only regenerate the
tables if the content has changed.

Copy: This copies all DPM data from ASI->MOIP or MOIP->ASI


either the ASI output to the
MOIP output (MPEG over IP)
or from the MOIP output to the
ASI output depending on your
selection.

ASI/MOIP

Menu Item Description Parameters

PE Select the Program Entry to 1 to 8 (main program)


configure.
1A to 8A (auxiliary program)
InCh Displays the channel number to 1 to 65535
which the PE is tuned. This is
read-only.

PMT Indicates the input PID value of 2 to 8190


the Program Map Table for the
current channel. This is read-
only.

100 OL-31980-01
Setup Menu

Menu Item Description Parameters

Act Selects the action to perform on Pass (default) - Output channel is the
the current program entry. same as the input channel. The
OutCh, and PMT settings are ignored.
This setting controls the overall
All PID map entries are ignored
DPM behavior of the PE and
except for entries that explicitly drop
will affect how the PID
a service.
mapping operates.
Map - The output channel is mapped
to the OutCh and PMT settings. Only
services which have entries in the PID
map are available on the output.
These services will appear in the PMT
even if the stream is not present.
Note: If the PE is mapped, it uses the
last valid (or saved) configuration.
The output map (for example, output
channel PMT) does not change
automatically if the input or channel
number is changed.
Drop - The current channel is not sent
to the output and its PMT is removed
from the output. The OutCh, PMT,
and PID map entries are ignored.
XCode - Provides the flexibility to
define all the outgoing PID numbers
for a PE, including those not currently
on transmission, as in Map mode,
plus the video PID is transcoded to
output at the rate and settings defined
for the transcode channel.
Note: The Auxiliary Programs (P1A
to P8A) cannot be set to XCode. Also,
they are automatically dropped when
the corresponding Main PE is not
transcoding.
OutCh If mapping the current PE (Act 1 to 65535
was set to Map), set the output
channel number for the current
program.

PMT If mapping the current PE (Act 2 to 8190


is set to Map), set the output
PID of the PMT.

OL-31980 -01 101


Chapter 4 Front Panel Operation

Menu Item Description Parameters

PID Press Select to view and


configure the PID map. The PID
map is used to map input
services to output PIDs. For
more information, see PID Map
Menu (on page 104).

Map Mode Select the DPM mapping mode Svc ID - The elementary PIDs are not
for the current output. changed. Channels are remapped by
changing their PSI references. When
this mode is selected, PID mapping in
the PID Map menu is ignored.
Svc ID & PID - Channels and the
elementary service PIDs can be
mapped using the PID Map menu.

Duplic Mode Select how to handle duplicate PSI Remap - Every input PID can be
programs. This setting is only mapped to only one output PID. If
used if the Map Mode menu is PID mapping conflicts exist, DPM
set to Svc ID & PID. will use the Precedence Rule to decide
which output PID to use. All PMTs
using the input PID will be updated
to reference the output PID specified
by the winner.
Pkt Copy - An input PID can be
mapped to multiple output PIDs. The
PID will be duplicated as many times
as needed (up to a certain hardware
limitation).
Note: This may increase the output
bandwidth of the stream.
Pkt Copy is recommended for most
applications.
Unref Select the action to use for Drop or Pass
unreferenced content.
Drop - All unreferenced content is
Unreferenced content is the
dropped.
remainder of the transport
stream that is not filtered by the Pass - All unreferenced content is
program entries. passed to the output unchanged.

102 OL-31980-01
Setup Menu

Menu Item Description Parameters

PSI Options Select the action to perform on Pass All - Transmits the incoming PSI
the PSI tables for the output Tables as is; does not modify the
stream. content and rate. The PSI Rate and
Note: The table menus (PAT, table settings are ignored.
CAT, PMT, TSDT, NIT, NITO, Drop All - Does not transmit any PSI
Tables. The PSI Rate and table
SDT, SDTO, BAT, EIT, TDT,
settings are ignored.
RST, TOT, DIT, SIT, ECM,
EMM, DRT, CDT) will only Ctl by Table - Configure the table
appear if you select Ctl by specific output mode for each table.
Table.

PSI Rate If the PSI Options was set to Auto - Matches the generated PSI
Ctrl by Table, select the tables' output rate to the incoming
regeneration rate for those PSI rate.
tables being regenerated.
MPEG Min - Transmits the generated
PSI tables on the longest intervals that
are allowed by MPEG standard.
SA Std - Transmits the generated PSI
tables based on PowerVu standard
intervals.

Service ID Select whether the receiver Valid Ch - Only transmits the PSI
should always generate PSI tables for the mapped program if the
tables for the Mapped PE even program exists on the input stream.
if the selected input channel is
All Ch - Transmits the PSI tables for
not available, or for only valid
the mapped program even if the
service channels/IDs.
program does not exist in the input
stream.
All Ch is only valid if the PAT, NIT,
SDT and PMT are set to Regenerate.

PAT, CAT, PMT, Selects the tables which will be


TSDT, NIT, NITO, passed, dropped, regenerated,
or passed with rate control
SDT, SDTO, BAT,
(PwRC) from the output. For
EIT, TDT, RST,
more information, see PSI
TOT, DIT, SIT, ECM, Table Settings (on page 105).
EMM, DRT, CDT
Note: The table settings are
only available if you selected
Ctl by Table in the PSI Options
menu.

OL-31980 -01 103


Chapter 4 Front Panel Operation

Menu Item Description Parameters

PE Resync: All, Each PE output can be Svcs - Map the input to the output
Template, PIDs, Svcs synchronized to its input based on the services only.
according to one of four output
PIDS - Map the input to the output
modes. For information on
based on the PIDs only.
synchronizing output services,
see Synchronizing Output All - Map the input to the output
Services (on page 108). based on the PIDs and services
Template - Map the input to a fixed
template output.

PAT/PMT Offset This is a customer-specifi c


mode, only to be used if
directed by Cisco. For more
information, contact Cisco
customer support.

NIT Offset This is a customer-specifi c


mode, only to be used if
directed by Cisco. For more
information, contact Cisco
customer support.

PID Map Menu


This menu allows the PID Map to be configured. The PID map is used to map input
services to output PIDs.
If the PE action is Pass, or PE action is Map and Map Mode is Svc ID, only entries
which drop a service are applied and all other services are passed through. If the PE
action is Map and Map Mode is Svc ID & PID, all entries are applied. Any services
not mapped by an entry will be dropped.
Press up and down to scroll through the PID map entries. Press ADV to insert or
delete entries from the PID map. After inserting an entry, specify the service using
OutType and In, and set the desired Action. If the action is Map, select the output
PID value as well. Then press APPLY and save the settings to see the selected input
service that will follow that mapping.

Menu Item Description Parameters

ITyp Displays the input service that


will be mapped by the current
entry. This value is read-only
and for reference purposes.

PID Displays the input PID that will 1 to 8190


be mapped by the current
entry. This value is read-only
and for reference purposes.

104 OL-31980-01
Setup Menu

Menu Item Description Parameters

Act Select the action to perform on Map - The service selected by the
the current PID. OutType and Instance will be
mapped to the specified PID. This is
The Drop action is always
only applied if the PE action is set to
performed, but the Map option
Map or XCode.
is only applied if the PE action
is set to Map or XCode. Drop - The service selected by the
OutType and Instance will be
removed from the PMT and the
output stream.

StTyp Enter the stream type to map 0 to 255


within a PE to a specified PID.

OTyp Select the service to configure. UNKN, ETV, CDT, LSDT, DATA,
If an input service matches this TTX, MPE, DPI, VBI, SUBT, AUD,
type and instance specified by VID, PCR or INVL
In, then the Action will be
applied.

In Select the instance of the service 1 to 64


specified by OType to
configure. If an input service
matches this type and instance,
then the Action will be applied.

PID If mapping this PID (Act is set 1 to 8190


to Map), select the output PID
number.

PSI Table Settings


Note: The table settings are only available if you selected Ctl by Table in the PSI
Options menu. The default values for the PSI table settings are dependent on the
Output Mode. For a list of default values, see DPM Default Settings for Different
Output Modes (on page 351).

Setting Mode Options Description

PAT Pass, Drop, Regen Program Association Table

CAT Pass, Drop, Regen Conditional Access Table

PMT Pass, Drop, Regen Program Map Table

TSDT Pass, Drop Transport Stream Description


Table

NIT Pass, Drop, Regen, PwRC Network Information Table

OL-31980 -01 105


Chapter 4 Front Panel Operation

Setting Mode Options Description

NITO Pass, Drop, PwRC Network Information Table -


Other
SDT Pass, Drop, Regen, PwRC Service Description Table

SDTO Pass, Drop, PwRC Service Description Table - Other

BAT Pass, Drop, PwRC Bouquet Association Table

EIT Pass, Drop Event Information Table

TDT Pass, Drop Time and Date Table

RST Pass, Drop Running Status Table

TOT Pass, Drop Time Offset Table

DIT Pass, Drop Discontinuity Information Table

SIT Pass, Drop Selection Information Table

ECM Pass, Drop Entitlement Control Message

EMM Pass, Drop Entitlement Management


Message
DRT Pass, Drop Disaster Recovery Table

CDT Pass, Drop Code Download Table

Note: The CDT is different from the other tables listed because the CDT is referred to
within the PMT, rather than outside the PMT. Select Pass to permit the output of
CDTs following the configured DPM PID map configuration and all other DPM
constraints. If a DPM PID map has not been configured for the CDT PID and the PE
Act is set to Map, the CDT will still not output. Select Drop to override the DPM PID
map configuration for CDT PIDs and to always drop all CDTs.

Setting Up Digital Program Mapping (DPM)


To set up DPM:
1 Verify that you are receiving a valid signal and that you have set up the channels
that you want to pass, drop or map.
2 Go to the Setup: Outputs, TS Out: DPM: Global menu and select Resync All for
the selected ASI output. This copies the input services PIDs to the remapped
output service PIDs.
3 Go to Setup: Outputs: TS Out: DPM: ASI, and select the PE containing the
channel you want to configure.
4 Set the Act for the selected PMT to either Pass, Drop, XCode, or Map depending
on the action desired. For more information on each mode, see ASI/MOIP1 (see
"ASI/MOIP" on page 100).

106 OL-31980-01
Setup Menu

5 Use the RIGHT arrow key to move to the right and select PID to display the
detailed menu level.
6 Configure the input to output channel mapping. Video and PCR can be output
on the same PID or different PIDs. If output on the same PID, they will appear
identical to the input.
Note: If the parameters cannot be saved, the problem may be that the incorrect
Map Mode has been selected. Ensure that Svc ID & PID is selected when
remapping PIDs, otherwise a message such as “Bad configuration data” will be
displayed and you will need to change the parameters to obtain the correct
output.
7 Go to Setup: Outputs, TS Out: ASI, and set the Output Mode to Full DPM
Control. Also, if necessary set the Descramble Mode according to whether the
program is to be Scrambled or Descrambled for downstream
viewing/monitoring.
8 On the same menu, set the following parameters:

Parameter Description
Map Mode Svc ID & PID

Duplic Mode Pkt Copy

Unref Drop

PSI Options Ctl By Table

PSI Rate Any

Svc ID Any

9 Set the table parameters as follows:

Parameter Description
PAT Regen

CAT Regen

PMT Regen

TSDT Drop

NIT Regen or Drop

NITO Drop
SDT Regen

SDTO Drop

BAT Drop

EIT Drop

TDT Pass

OL-31980 -01 107


Chapter 4 Front Panel Operation

Parameter Description

RST Pass

TOT Pass

DIT Pass
SIT Pass

ECM Drop

EMM Drop

DRT Drop

CDT Drop
10 Press MENU three times to exit the TS Out menu and save the data. If the
changes cannot be saved/made, a message will be displayed indicating "Bad
configuration data". The following options are available: Abandon, Exit or
Return. Select Return to re-enter the parameter.
Note: When remapping an input program channel to an output channel, ensure
that the PIDs are mapped to different PIDs to avoid PID collisions.

Sy nchronizing Output Serv ices


To synchronize the output to the input Services Only:

This operation synchronizes the inputs to the outputs according to the service
assignments only. This is useful when you already have PID as signments set for the
services but want to ensure that the services are mapped correctly.
1 On the DPM menu, map the output services as desired.
2 Select PE Resync: Svcs. The receiver will synchronize the PE output according to
the available input services only, and ignore the input to output service PID
mapping.
To synchronize the output to the input PIDs only:
This operation synchronizes the inputs to the outputs according to the PID
assignments only. This is useful when you have already have the services set up but
want to synchronize to the incoming PIDs.
1 On the DPM menu, map the output services as desired.
2 Select PE Resync: PIDs. The receiver will synchronize the PE output according to
the input PIDs only, and ignore the service assignment categories/names.

To synchronize the output to All (Services and PIDs):


This operation synchronizes the inputs to the outputs of the current PMT according
to the service assignments and then the PID assignments. This is similar to a sample
and hold function.
1 On the Detailed Program Mapping Active menu, map the outputs services as
desired.
108 OL-31980-01
Setup Menu

2 Select PE Resync: All. The receiver will synchronize the PE output according to
the services and then the PIDs assigned to each service.
To synchronize the output to a Template:

Using a template allows you to preset the input to output mapping of a PE according
to the preset template. This is helpful in pre-configuring any number of PEs for
future use.

TS Out - Transcode
To view the Transcode menu from the TS Out menu, press the RIGHT arrow key
three times.
The Transcode menu allows you to convert MPEG-4 HD services to MPEG-2 for use
in CATV headends. Video and two audio monitoring outputs are available for
confidence monitoring of the decrypted incoming MPEG-4 HD program.
The Transcode menu has the following structure:

OL-31980 -01 109


Chapter 4 Front Panel Operation

Transcode

Menu Item Description Parameters

PE This selects the transcoder 1 to 8


index as referenced by DPM.

Video Mode This selects the transcode Auto - Leaves the input video
channel video mode. format and resolution unchanged.
e.g., SD in - SD out, HD in - HD
out.
SD Output - Down-converts from
HD to SD when receiving an HD
input signal. SD horizontal
resolution will follow the SD Res
parameter set on this menu.
HD Output - Up-converts from SD
to HD1080i when receiving an SD
input signal. HD horizontal
resolution will follow the HD Res
parameter on this menu.
HD720p - Sets the output vertical
resolution to HD720p regardless of
the input resolution.
HD1080i - Sets the output vertical
resolution to HD1080i, regardless
of the input resolution.

HD HRes This selects the transcode Full or 3/4


channel HD horizontal output
Setting Description
video resolution.
Input Output
Resolutio Resolution
n

Full 1080i 1920

3/4 1080i 1440

Full 720p 1280

3/4 720p 960

SD HRes This selects the transcode 352, 480, 528, 544, 704, or 720
channel SD horizontal output
video resolution.
HD/SD B/R Mode This selects the transcode CBR or VBR
channel output bit rate mode.

HD Bitrate This sets the transcode channel 8 to 25 Mb/s in 400 b/s


output bit rate when HD increments. The default is 16.0
MPEG-4/ AVC to HD MPEG-2 Mb/s.
transcoding is selected.

110 OL-31980-01
Setup Menu

Menu Item Description Parameters

SD Bitrate This sets the transcode channel 2 to 15 Mb/s in 400 b/s


output bit rate when HD to SD increments. The default is 4.0
transcoding is selected for the Mb/s.
output channel.

HD/SD GOP This selects the Transcode User GOP (MN), I Frame Sync, or
Control Group of Pictures (GOP) Fixed GOP
format.

HD/SD User GOP This selects the transcode Supported GOP structures - 1 0, 12
manual GOP format value. The 2, 15 2, 24 2 or 30 2
(M N)
transcoder attempts to reuse
information from the encoded
bit stream to improve the video
quality of the transcoded
stream. Amongst others, if the
incoming GOP structure is
similar to that of an MPEG-2, it
will reuse the frame allocations
from the incoming stream as
long as GOP Control is set to I
Frame Sync. If the downstream
transcoder does not support
altering GOP structures, set the
GOP Control setting to User
GOP (MN). This will also
require the setting of the GOP
structure which is given as two
numbers, where the first is the
length of the GOP and the
second is the number of B-
pictures per sub-GOP.
HD/SD 3:2 This enables or disables 3:2 Enabled or Disabled
Pulldown pulldown.
SD Aspect Ratio This selects the HD/SD 4:3 or 16:9 (wide aspect ratio). The
transcode channel aspect ratio. default is 16:9. Set it to the
corresponding value.

SD AR Conv This selects the HD/SD Auto, None, 16:9 L/B (letter box),
transcode channel aspect ratio 4:3 P/B (pillar box), 14:9, 4:3 CCO,
conversion. This is the 16:9 SCALE or Auto AFD (Auto
conversion that the transcoder setting using Active Format
will perform on the output Descriptor). The default is set to
signal for the picture to be Auto. See Setup Menu: Services (on
displayed correctly (i.e., to page 76) for more information.
correspond to the aspect ratio
of your TV) on your TV, based
on your selection.

OL-31980 -01 111


Chapter 4 Front Panel Operation

Menu Item Description Parameters

CC Pkt 1, CC Pkt 2 This selects the order to output None, SCTE-20, or CEA 708. The
the closed caption packets on default is CEA 708.
the transcoded SD output.
LOI Action This selects the transcode Loss No Output or Black Output
Of Input (LOI) Action, which is
the action that the transcoder
takes when there is a loss of
input signal.

Setting Up Transcoding
To set up the transcode channel:
1 Verify that you are receiving a valid signal and that you have set up the channels
that you want to transcode.
2 Go to Setup: Outputs: TS Out: DPM: ASI, and set the Output Mode to
Transcoding. You will be prompted to Resync All for the selected output. This
resynchronizes the inputs to outputs for the current PMT according to the service
assignments and the PIDs for the PE.
3 Press MENU to exit the menu and save the data. If the changes cannot be saved/
made, a message will be displayed indicating “Bad configuration data”. In this
case, the menu will revert to the previously saved configuration. Note: When
remapping an input program channel to an output channel, ensure that the PIDs
are mapped to different PIDs to avoid PID collisions.
4 If desired, set a program channel for the second transcoder channel, PE2, and
repeat step 2. See LCD Symbol (on page 40) for more information on assigning a
program channel to a PE.

Inband

Menu Item Description Parameters

PE This selects the transcoder 1 to 8


index as referenced by DPM.

Apply Inband This applies the uplink Yes or No


parameters for transcoding,
such as bitrate, GOP and
resolution, to the local
transcoder settings for the
selected program entry. This is
only supported with an uplink
that uses uplink transcoding
controls for the user address of
the selected program entry.

112 OL-31980-01
Setup Menu

TS Out - Options
To view the Options menu from the TS Out menu, press the RIGHT arrow key four
times.
The Options menu allows you to configure auto synchronization and fixed output
options for the MPEG over IP and ASI outputs.

The Options menu has the following structure:

TS Output Options

Menu Item Description Parameters


Output Select 1 to configure the ASI 1 or 2
output or select 2 to configure
the MPEG over IP output.
Fixed Output Sets whether the DPM assigns Yes or No
new values for all the output
channels and PIDs according to
the options below when you
Resynchronize All.

OL-31980 -01 113


Chapter 4 Front Panel Operation

Menu Item Description Parameters

Use Inp Set to Yes to use the input Yes or No


Chan/PMT/PIDs channel numbers, PMT PID
numbers, and/or ES PID
numbers. Otherwise, set to No
to use the Start channel and
channel Step assigned below.

Start First PE channel to use if the 1 to 65535 for Use Inp Chan
Use Inp Chan/PMT/PIDs is set
1 to 8192 for Use Inp PMT/PIDs
to No.

Step Offset of the subsequent PE 1 to 65535 for Use Inp Chan


channel, PE PMT PID, or first
1 to 8192 for Use Inp PMT/PIDs
ES PID of subsequent channel
numbers.

Use Inp Ord Set to Yes to assign the ES PID Yes or No


according to the incoming PMT
order. Otherwise, set to No to
use reserved PIDs defined
below.

PCR, VID, AUD, Set the number of PIDs for the 1 to 64


SUBT, VBI, DPI, specified streams in one
MPE, TTX, Data, channel.
LSD, CDT, ETV

114 OL-31980-01
Setup Menu

Setup Menu: CA
To view the CA menu from the Main menu, press the RIGHT arrow key once and
then the SELECT key to reach the Setup menu. Then press the RIGHT arrow key six
times and the SELECT key to view the CA menu.

The CA menu provides information about the ISE, the status of the ADP
transmission, and allows you to set the BISS mode and session words available from
your service provider. The CA menu has the following structure:

Menu Item Description Parameters

ID Select the ISE to configure. 1 to 8

User Address Indicates the ISE User Address. 11 digit address in the following
format: ###-###-####-#

ISE Version Indicates the ISE version number. 7 characters

ADP Enc Pass Indicates the number of encrypted


Addressable Data Packets
successfully processed. Ideally, the
ADP Enc Pass and ADP Enc Total
numbers should be identical.

OL-31980 -01 115


Chapter 4 Front Panel Operation

Menu Item Description Parameters

ADP Enc Total Indicates the total number of


encrypted Addressable Data Packets
received. Ideally, the ADP Enc Pass
and ADP Enc Total numbers should
be identical.

ADP Non-Enc Pass Indicates the number of non-


encrypted Addressable Data Packets
successfully processed. Ideally, the
ADP Non-Enc Pass and ADP Non-
Enc Total numbers should be
identical.

ADP Non-Enc Total Indicates the total number of non-


encrypted Addressable Data Packets
received. Ideally, the ADP Non-Enc
Pass and ADP Non-Enc Total
numbers should be identical.

Clear ADP Counts Select to clear the Addressable Data


Packet counters: ADP Enc Pass, ADP
Enc Total, ADP Non- Enc Pass and
ADP Non-Enc Total. These values
are also reset whenever the receiver
is turned on, reset or power-cycled.
BISS Mode Sets the Basic Interoperable Mode 1 or Mode E
Scrambling System (BISS) mode for
the receiver. All channels assigned to
a PE identified as BISS CA-
controlled in the PMT will be
decrypted.

BISS-1 SW If BISS Mode is Mode 1, enter the 12-character password. Once


session word. entered, it cannot be viewed and
it is only displayed as asterisks
(*).
Contact your program provider
for the session word.

BISS-E ESW If BISS Mode is Mode E, enter the 16-character password. Once
encrypted session word. entered, it cannot be viewed and
it is only displayed as asterisks
(*).
Contact your program provider
for the session word.

116 OL-31980-01
Setup Menu

Menu Item Description Parameters

BISS-E IID If BISS Mode is Mode E, enter the 14-character password. Once
injected ID. entered, it cannot be viewed and
it is only displayed as asterisks
(*).
Contact your program provider
for the session word.

Setup Menu: Alarm/Warning


To view the Alarm/Warning menu from the Main menu, press the RIGHT arrow
key once and then the SELECT key to reach the Setup menu. Then press the RIGHT
arrow key seven times and the SELECT key to view the Alarm/Warning menu.

The Alarm/Warning menu allows you to browse the active alarms and warnings,
and set whether the output will be disabled in the event of an alarm. This menu has
the following structure:
Alarm/Warning
FP Alarm Reminder Alarm Vid Cutoff i s

Disable Disable

System Alarm Name Enb Rly Trp i s

Loss Of Signal Yes Yes Yes

System Warning Name Enb Rly Trp i s

PMT Timeout Yes Yes Yes

Menu Item Description Parameters

FP Alarm Reminder Select whether to display Enable or Disable


alarms and warnings on the
front panel. The alarm indicator
will intermittently flash in the
lower line, if enabled.

OL-31980 -01 117


Chapter 4 Front Panel Operation

Menu Item Description Parameters

Alarm Vid Cutoff Select whether the video output Enable or Disable
is cut off if any enabled alarm is
The default is Disable.
active on the receiver. When
video is cut off, there will be no
horizontal or vertical
synchronization on the output.
This is useful for downstream
redundancy switching by
detecting a loss of video signal.
Note: This function also exists
under Setup: Services: Video.

System Displays the alarm or warning


Alarm/Warning to configure.
Name

Enb Select whether the current Yes or No


alarm is enabled or disabled. If
the alarm is disabled, the Rly
and Trp settings are ignored

Rly If the current alarm or warning Yes or No


is enabled (Enb is set to Yes),
Note: No is a read only value that
select whether it will trigger the
indicates the setting is Yes, but is
rear panel relay when the alarm
currently being suppressed because
is set or cleared.
the alarm or warning is disabled (Enb
is set to No).

Trp If the current alarm or warning Yes or No


is enabled (Enb is set to Yes),
Note: No is a read only value that
select whether it will send
indicates the setting is Yes, but is
SNMP trap messages when the
currently being suppressed because
alarm is set or cleared.
the alarm or warning is disabled (Enb
is set to No).

118 OL-31980-01
Setup Menu

Setup Menu: Noise Cutoffs


To view the Noise Cutoffs menu from the Main menu, press the RIGHT Arrow key
once and then the SELECT key to reach the Setup menu. Then press the RIGHT
arrow key eight times and the SELECT key to view the Noise Cutoffs menu.

The Noise Cutoffs menu allows you to set the muting thresholds for both audio and
video in the event of a noisy signal. This menu has the following structure:
Noise Cutoff
Trnsprt(DVBS Marg) Cutoff Restore i s

0.0 0.1

Audio(DVBS Marg) Cutoff Restore i s

0.0 0.1

Trnsprt(DVBS2 Marg) Cutoff Restore i s

0.0 0.1

Audio(DVBS2 Marg) Cutoff Restore i s

0.0 0.1

Restore Defaults Muting Control i s

Yes Disable

Menu Item Description Parameters

Trnsprt(DVBS Marg) Sets the DVB-S and DVB-S2 -30.0 to 30.0


Cutoff Carrier to Noise margins, in dB,
This setting must be below the
below the transport outputs that
Trnsprt(DVBS2 Marg) respective Restore value.
will be muted.
Cutoff
The default is 0.0.
The receiver uses these
thresholds to determine when to Note: Muting Control must be set
mute the transport in the event to Enable for these settings to be
of a noisy signal, poor, or loss of active.
signal condition.

Trnsprt(DVBS Marg) Sets the DVB-S and DVB-S2 -30.0 to 30.0


Restore Carrier to Noise margins, in dB,
This setting must be above the
above the transport outputs that
Trnsprt(DVBS2 Marg) respective Cutoff value.
will be muted.
Restore
The default is 0.1.
The receiver uses these
thresholds to determine when to Note: Muting Control must be set
restore the transport after it has to Enable for these settings to be
been muted. active.

OL-31980 -01 119


Chapter 4 Front Panel Operation

Menu Item Description Parameters

The following displays the Transport Default C/N Margin


Relationship

Audio(DVBS Marg) Sets the DVB-S and DVB-S2 -30.0 to 30.0


Cutoff Carrier to Noise margins, in dB,
This setting must be below the
below the audio outputs that
Audio(DVBS2 Marg) respective Restore value.
will be muted.
Cutoff
The default is 0.0.
The receiver uses these
thresholds to determine when to Note: Muting Control must be set
mute the audio in the event of a to Enable for these settings to be
noisy, poor, or loss of signal active.
condition.

Audio(DVBS Marg) Sets the DVB-S and DVB-S2 -30.0 to 30.0


Restore Carrier to Noise margins, in dB,
This setting must be below the
above the audio outputs that
Audio(DVBS2 Marg) respective Cutoff value.
will be restored.
Restore
The default is 0.1.
The receiver uses these
thresholds to determine when to Note: Muting Control must be set
restore the audio after it has to Enable for these settings to be
been muted. active.

The following displays the Audio Default C/N Margin Relationship

120 OL-31980-01
Setup Menu

Menu Item Description Parameters

Restore Defaults Select to restore the default


muting thresholds.

Muting Control Select whether to enable or Enable or Disable.


disable muting cutoffs.
The default is Enable.
If disabled, all the other settings
are ignored.

Setup Menu: DR
To view the DR (Disaster Recovery) menu from the Main menu, press the RIGHT
arrow key once and then the SELECT key to reach the Setup menu. Then press the
LEFT arrow key once and the SELECT key to view the DR menu.

The DR menu allows you to set up the disaster recovery parameters. For more
information on disaster recovery, see Disaster Recovery (on page 6).
Each parameter is described below. The menu has the following structure:

OL-31980 -01 121


Chapter 4 Front Panel Operation

Global

Menu Item Description Parameters

D/R Enable Choose to enable or temporarily disable Yes or No


the disaster recover feature. Choose Yes
(default) to enable disaster recovery.
Choose No to set the disaster recovery into
maintenance mode. It will automatically
set the Disaster Recovery back to Yes after
five minutes. This prevents the user from
accidentally disabling disaster recovery
permanently. To disable disaster recovery,
remove all of the disaster recovery
configurations (Backup Channel and
Backup Transport settings).
The maintenance mode allows you to
perform any maintenance operations (such
as IP setup), without the unit declaring
disaster and initiating a disaster recovery
search path.
Note: Although the default is set to Yes,
the disaster recovery is not operational
until the search path is configured.

Signal Loss Timer Select the time, in seconds, the unit must 5 to 2160000 seconds
wait (after detecting a signal loss) before
declaring a disaster. The default is 120
seconds.

Signal Lock Timer Select the time, in seconds, the unit must 5 to 255 seconds
wait for a signal lock before declaring that
the signal is not usable and move on to the
next search location in the search path. The
default is 30 seconds.

Verify Timer Select the time, in seconds, the unit must 10 to 255 seconds
wait for the PAT table to verify the signal
has a valid transport. The default is 60
seconds.

122 OL-31980-01
Setup Menu

Backup Channel

Menu Item Description Parameters

PE # The Program Entry (PE) number you are PE1 to PE8


configuring the backup transport channel.
The transcoder supports eight program
entries (PE1 to PE8). PE1 is the decode
channel and is available at the analog
outputs. PE2 to PE8 are available for the
transcoded channels on the ASI and MPEG
over IP outputs.

Transport The backup transport number you are 1, 2, or 3


configuring the backup channel.
Backup Channel The backup channel number for the –
selected backup transport.
Note: We recommend that you configure a minimum of one backup transport. If no backup
transport is configured, an alarm is triggered, but the unit will not be able to switch to a
backup transport.

Backup Transport

Menu Item Description Parameters

Backup The backup number 1, 2, or 3


Active Indicates whether the selected backup is Yes or No
enabled.
To activate a backup, press the ADV key
and press SELECT to insert. The Active
menu for the selected backup number
changes from No to Yes. Press APPLY to
save the changes.
To disable a backup, press the ADV key
and press the RIGHT arrow once and
press SELECT to select Delete. Press the
RIGHT arrow once and press SELECT to
select Continue. The Active menu for the
selected backup number changes from Yes
to No.

Input, NetId, Freq For information on the tuning parameters, –


(GHz), SymRate, see RF1, RF2, RF3, RF4 (RFx) Input (on
FEC, Backup, page 63).
Modulation, Rolloff Note: The RF input must be configured to
match the bandwidth of the backup
parameters.

OL-31980 -01 123


Chapter 4 Front Panel Operation

About Menu
To view the About menu from the Main menu press the RIGHT arrow key two
times and then the SELECT key.

The About menu provides basic hardware information that is useful when
requesting customer support from Cisco.
Each parameter is described below. The About menu has the following structure:

General
Menu Item Description

Host Name Sets the host name of the current unit. It is a user configurable name that
appears on the Web Interface title to identify the transcoder.

Tracking ID Displays the unique Tracking ID number that identifies the product version.
This is read-only.

Model Indicates the model number and name of the transcoder. This is read-only.

Master UA Indicates the Master User Address (UA), which is required to request
program authorization from the uplink. This is read-only.

Ver Indicates the version number of the ISE.

Serial Number Indicates the unique device serial number.

Customer Code Indicates the unique Customer Code assigned to an organization by Cisco.

Board ID Indicates the hardware board design identification.

Revision Indicates the revision number of the board design.

MAC Address Indicates the MAC address of the Control Port Ethernet interface.

124 OL-31980-01
About Menu

Menu Item Description

FPGA Type Indicates the FPGA type and number information.

Licenses
Menu Item Description Parameters

Feature Displays HD Transcode License Count or SD N/A


Transcode License Count

Enb HD Transcode License Count - Displays the 0 to 8


number of program entries that can perform
both SD and HD transcode.
SD Transcode License Count - Displays the
number of program entries that can perform
SD transcode only.
For example, a fully licensed D9859 transcoder,
with additional 6 SD and 7 HD upgrades, is
displayed as 8 for the HD Transcode License
Count feature and 0 for the SD Transcode
License Count feature.

OL-31980 -01 125


Chapter 4 Front Panel Operation

Versions Menu
To view the Versions menu from the Main menu, press the RIGHT arrow key three
times and then the SELECT key.

The Versions menu provides basic software information that is useful when
requesting customer support from Cisco.
The menu has the following structure:

Main Versions
The following are the version numbers applicable to the Main printed circuit board.

Menu Item Description

App Current Indicates the version of the current application.

126 OL-31980-01
Versions Menu

Menu Item Description

App Safe Indicates the version of the factory loaded safe application.

App Safe Limit Indicates the version of the oldest application that can be
installed on the current unit. If this value is zero, the oldest
application limit is the App Safe version. If this is greater than
zero, the shown value or older and the App Safe version is the
limit. Older applications will not be installed.

Primary Indicates the versions of the primary and secondary


Boot/Secondary processors' boot code.
Boot

FPPIC Indicates the version of the front panel PIC microcontroller.

FPGA Safe Indicates the version of the factory loaded safe Field
Programmable Gate Array (FPGA) code.

FPGA Current Indicates the version of the current Field Programmable Gate
Array (FPGA) code.
Ver Register Indicates the version of FPGA code read from the FPGA.

CPLD Primary, Indicates the versions of the current primary and secondary
CPLD Secondary Complex Programmable Logic Device (CPLD).
Application, Select, Application - Select between all versions of the application
Erase loaded on the current unit.

Select - Select and then scroll to Yes to reboot the unit and load
the selected application. You will be prompted to continue or
abort this operation.
Note: Selecting an application will cause the unit to reboot
and interrupt service.
Erase - Select to erase the selected application. You will be
prompted continue or abort this operation. You cannot erase
the safe application or the current application. While an
application is being erased, the busy indicator will appear.
You cannot earse another application until it is complete.

OL-31980 -01 127


Chapter 4 Front Panel Operation

Menu Item Description

FPGA Version, FPGA Version - Select between all versions of the FPGA code
Select, Erase loaded on the current unit.
Select - Select and then scroll to Yes to reboot the unit and load
the selected FPGA code. You will be prompted to continue or
abort this operation.
Note: Selecting an FPGA code will cause the unit to reboot
and interrupt service.
Erase - Select to erase the selected FPGA code. You will be
prompted continue or abort this operation. You cannot erase
the safe FPGA code or the current FPGA code. While an FPGA
code is being erased, the busy indicator will appear. You
cannot earse another FPGA code until it is complete.

Transcoder Software Versions


The TranscoderSW version parameters list all the software packages used for the
D9859 transcoder. For more information on the software versions, contact Cisco
customer support.

Transcoder Hardware Versions


The following are the version numbers applicable to the Transcoder printed circuit
board.

Menu Item Description

Transcoder Board Rev Displays the Printed Circuit Board (PCB) revision of the
transcoder board.
MCL Indicates the hardware initialization version number for the
transcoder devices on the transcoder board.
MDL Displays the software version number that provides
software access to the transcoder devices.

Transcoder Displays the version of the firmware performing the


transcode.

Power Sequencer Indicates the firmware version running on the power-


sequencer, a chip that controls power-up and power-down
of multiple power supplies.

FPGA Indicates the Field Programmable Gate Array (FPGA)


version number.

Transcoder Board SN Indicates the serial number that is uniquely assigned to the
transcoder board.

128 OL-31980-01
Diagnostics Menu

Diagnostics Menu
To view the Diagnostics menus from the Main menu, press the RIGHT arrow key
four times and then the SELECT key.

For instructions on how to select and store settings, see About the Front Panel (on
page 34).

The Diagnostics menu has the following structure:

Alarms/Warnings
Menu Item Description

View History Select to view the system event messages. Press the UP and DOWN arrow
keys to scroll through the list of alarms and warnings. Press the LEFT and
RIGHT arrow keys to view the set and reset times. Press the INFO key to
view the detailed message.
Clear History Select to clear any existing history information.

Logs
Menu Item Description

View Logs Select to view the system log messages. Press the UP and DOWN arrow keys
to scroll through the list of log messages. Press the INFO key and then UP and
DOWN arrow keys to view the complete message text.

OL-31980 -01 129


Chapter 4 Front Panel Operation

Menu Item Description

Clear Logs Select to clear any existing log history information.

View DL Select to view the system download history messages. Press the UP and
DOWN arrow keys to scroll through the list of downloaded messages. Press
the INFO key and then UP and DOWN arrow keys to view the complete
message text.

PSI - Frequency Plan


This is the Frequency Plan sub-menu. You cannot make any changes here, but you
can view the available frequency plans stored in the receiver. Press the UP and
DOWN arrow keys to scroll through the list of available transports.

Menu Item Description Parameters

TxID Transport ID

Freq(GHz) Downlink Frequency (GHz) 0.0 to 15.0 GHz

FEC Forward Error Correction inner code rate 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 7/8,
8/9, or 9/10

Pol Polarity of the received signal (H, V, or Horiz (Horizontal), Vert


Off) (Vertical), Circ_l (Left Circular),
or Circ_r (Right Circular).

ONID Original Network ID

SymRate Symbol Rate, in Mbps

Modulation Modulation of the signal QPSK DVB-S, QPSK DVB-S2,


8PSK DVB-S2 or 16QAM DVB-S2

OrbPos Orbital Position of the satellite (in degrees) East or West

PSI - Channels
This is the Virtual Channel sub-menu. You cannot make any changes here, but you
can view the available channels and their settings. Press the UP and DOWN arrow
keys to scroll through the list of channels.

Menu Item Description

VC Virtual channel number.

TxID Identification number of the transport on which the channel is available. For
more information on the transport streams, see PSI - Frequency Plan (on page
130).

130 OL-31980-01
Diagnostics Menu

PMT PID of the channel's Program Map Table. It is displayed as ---- if unavailable.

EMC PID of the channel's Entitlement Control Message stream. It is displayed as ----
if unavailable or not scrambled.

Program Name Name of the channel.

PSI - Tables
This is the Tables received sub-menu. You cannot make any changes here, but you
can view the PSI tables received and their settings. Press the UP and DOWN arrow
keys to scroll through the list of tables.

Menu Item Description Parameters

Type The MPEG table acronym. PAT, CAT, PMT, TSDT, NIT, NIT
Other, SDT, SDT Other, BAT,
AEIT P/F, OEIT P/F, TDT, RST,
ST, TOT, DIT, SIT, ECM Odd,
ECM Even, EMM, MPE, DPI,
DRT, CDT, MCT, MIT, MAT,
ECT, or Invalid Table ID

Tbl-ID Unique Table ID.

ID MPEG/DVB Table ID.

Ver Table Version number.

PID Value of the PID on which the table is


present.

Status Reception status of the table. None, Partial, Full, Update,


Timeout, or Lost
Sections Number of sections in the table.

Power On
Menu Item Description

Creation Date and Displays the date and time the current unit was manufactured.
Time

Power On Date and Displays the date and time the current unit was last powered up, in relation to
Time the current local time.

Total Hrs Displays the total number of hours the current unit has been running since
being manufactured.

OL-31980 -01 131


Chapter 4 Front Panel Operation

Menu Item Description

Hrs Since Last Displays the number of hours the current unit has been running since the last
Pwroff power up.
Tot Rst #, Displays the total number of times the current unit has been reset since it was
manufactured.
Clrbl Rst # Displays the number of times the unit has been reset since the clearable reset
counter was last cleared.

Clr Rst # Select this option to clear/reset the Clrbl Rst # counter to 0.

Reason For Last Displays the reason for the last reset.
Reset

Health Monitor
Menu Item Description Parameters

Cur Temp, Max Displays the current (Cur Temp), maximum (Max Degrees Celsius
Temp, Avg Temp Temp) and the average (Avg Temp) operating
temperature.

Fan1 to Fan7 RPM Displays the fan speed for the internal fans. RPM

132 OL-31980-01
5 Chapter 5
Web GUI Setup and Monitoring
Introduction
This chapter describes how to set up the D9859 Advanced Receiver
Transcoder using the web GUI.

In This Chapter
 Logging O n to the Web GUI ............................................................134
 D9859 Summary Overview .............................................................135
 D9859 Menus ....................................................................................138
 D9859 Web GUI Environm ent .........................................................140
 Setting up Input Information ..........................................................141
 Setting up Audio and Video Information.......................................168
 Configuring T ransport Stream Information ...................................182
 Configuring S ystem Settings ...........................................................218
 Viewing Support Inf ormation .........................................................252

OL-31980 -01 133


Chapter 5 Web GUI Setup and Monitoring

Logging On to the Web GUI


1 Open a web browser.
2 Type the IP address of the D9859 Advanced Receiver Transcoder in the Address
bar and press Enter.

3 In the Username and Password fields, enter the username and password.
Note: The username and password are case-sensitive. The default username is
admin and the default password is localadmin. If you have forgotten your
username and password, you can reset them from the front panel menu of the
D9859 Advanced Receiver Transcoder. For more information, see Resetting the
Login Credentials (on page 32).
Important: The password and username will be remembered for the whole of the
web session. Close the web browser if you want to prevent others from accessing
the settings of the D9859 Advanced Receiver Transcoder.
If your session expires, you must refresh the browser and log back in.
4 Click Log in.
Note: If you check the Remember username check box, the user name will be
remembered the next time you log into the web GUI.

134 OL-31980-01
D9859 Summary Overview

D9859 Summary Overview


To access an overview of the main D9859 Advanced Receiver Transcoder settings:
From the user interface of the D9859, choose Summary > Summary Dashboard. The
Summary Dashboard page is displayed.

The Summary Dashboard page displays an overview of the main D9859 Advanced
Receiver Transcoder settings.

Shortcuts
The shortcuts below the modules in the Summary Dashboard page are shortcuts to
the various setup pages. For example, click Video Setup to open the Video Setup
page.

OL-31980 -01 135


Chapter 5 Web GUI Setup and Monitoring

Modules
You can customize the Summary Dashboard by temporarily minimizing or
removing the modules displayed. Each module has a maximize and minimize
button, allowing you to view or hide various modules. The default view is displayed
when you refresh the Summary Dashboard page.
You can also customize the Dashboard by clicking Add/Remove Module. The
Dashboard Configuration window is displayed.

The following table describes all the available modules:

Module Description

Decoded Program Status Displays channel and service information.

Audio Status Displays the current audio status information, such as


the audio format and sampling frequency.

Current Input Status Displays the current RF Tuning Status information,


including the downlink frequency and signal status.

Tuner Performance Displays the satellite dish status, such as the C/N
Margin and Signal Level.
Video Status Displays the current video information.

Channel Status Displays the channel status information, such as the


type of CA used and whether the receiver is
authorized to receive the signal.

PID Information Displays the PIDs associated with the channels.

Fault Active List Displays the currently active alarms and warnings.

136 OL-31980-01
D9859 Summary Overview

Alarms/Warnings
The bottom right corner of the Summary Dashboard page displays the total number
of active alarms, active warnings, and clear messages. Clear messages is calculated
as follows: total number of alarms + total number of warnings - total number of
active alarms - total number of active warnings.
To view a detailed list of alarms and warnings, click the Alarms or Warnings link
and a pop-up window is displayed with a list of all the active alarms or active
warnings. The following is an example:

Click on an alarm or warning to open the Status page for more information. For
more information on the Status page, see Viewing the Alarm/Warning Status (on
page 231).

OL-31980 -01 137


Chapter 5 Web GUI Setup and Monitoring

D9859 Menus
The web GUI of the D9859 has menus at the top of the page.

The functions for the menus are as follows:

 Summary
From this menu, you can obtain an overview of the D9859 operation.
 Input
From this menu, you can:
- set up RF and ASI inputs,

- configure muting thresholds,


- view input status,

- configure disaster recovery settings,


- configure channels,

- configure CI (Common Interface) settings,


- view PSI, Frequency, and Channel tables.

 Audio & Video


From this menu, you can:
- configure video settings,

- set up closed caption and subtitles,


- configure audio settings,

- view current audio status,


- set the cueing parameters.

 Transport Stream
From this menu, you can:

- configure ASI and MPEGoIP outputs,


- configure transcoder settings.

 System Settings
From this menu, you can:
- view alarm and warning status information

138 OL-31980-01
D9859 Menus

- configure ethernet ports,

- set date and time formats,

- configure lock levels.


 Support
From this menu, you can:
- view logs,

- view contact information,


- view and upgrade software version.

OL-31980 -01 139


Chapter 5 Web GUI Setup and Monitoring

D9859 Web GUI Environment


The following is an example of a D9859 Web GUI page:

Window Buttons
The GUI of the D9859 has the following general buttons:

Button Description

Apply Saves and applies the settings to the transcoder.

Refresh Reads existing data from the D9859. If edits were made in a setup page,
then unsaved changes are discarded.

Reset Defaults Discards any changes made and sets data to default values.

Clear Counters Resets counters on the displayed page.

140 OL-31980-01
Setting up Input Information

Setting up Input Information


Setting up the RF Input
1 From the user interface of the D9859, choose Input > Input Setup. The Input
Setup page is displayed.

2 In the RF Input Selection area, check the Use RF Input check box to activate an
RF input. You can select RF 1 to RF 4 below.
3 Choose UserCfg from the Input Selection to lock to the RF input set by the user.
Choose SW Map to use the orbital position settings to select the RF input. We
recommend that you validate the orbital position for SW Map option.
4 Click the Use RF 1, Use RF 2, Use RF 3, or Use RF 4 radio button to activate an
RF input.

OL-31980 -01 141


Chapter 5 Web GUI Setup and Monitoring

5 In the Tuning area, enter the current operating downlink frequency used by the
transcoder for tuning the received digital signal in the Downlink Frequency
field. You can enter a value in the range from 0.0 to 15.0 GHz.
6 In the Symbol Rate field, enter the symbol rate that matches the transmitted
signal. You can enter a value in the range from 1.0 to 45.0 Ms/s for DVB-S, 1.0 to
30.0 for DVB-S2 if Pilot Present is set to Yes on the Front Panel, or 5.0 to 30.0 for
DVB-S2 if Pilot Present is set to No on the Front Panel.
7 From the FEC drop-down list, choose the Forward Error Correction inner code
rate. The FEC rate must match the FEC of the transmitted signal. You can select
1/2, 2/3, 3/4, 5/6, 7/8, or Auto.
8 From the Modulation drop-down list, choose the modulation type for the
received signal (DVB-S or DVB-S2).
9 From the Roll Off drop-down list, choose the roll-off factor of the incoming
signal (.20, .25, .35). Set the value to .20 or .35 when DVB -S modulation is used,
and either of the three when DVB-S2 is used. Use a small number to reject or
filter carriers close to the same frequency.
10 From the IQ drop-down list, choose the input signal spectrum inversion setting,
which allows the operator to track and select inverted and non-inverted digital
signals. This is normally used to automatically reject or filter out unwanted
signals.
When set to Auto, signal is tracked and inverted for correct selection, as
required. When set to Opposite, the signal is always inverted. Conversely, when
set to Normal, the signal is not inverted.
11 The RF1 22KHz is only applicable for dual band applications. Select whether to
transmit the 22 kHz tone Local Oscillator control signal of RF1. The selections are
On, Off, or Auto. Select Auto to use the crossover frequency to determine if the
tone is transmitted.
12 From the RF1 Power drop-down list, choose the power output of RF1 to the
external Low Noise Block (LNB).
You can set the RF1 Power to Off, 13V, 18V, V-NIT or H-NIT. When RF1 Power
is set to V-NIT or H-NIT, it will use vertical and horizontal polarity until it is
automatically read from the NIT.
Note: Power will not be applied to the LNB when set to Off.
13 In the RF Input LNB Configuration area, for RF1, RF2, RF3, and/or RF4, set the
lower local oscillator frequency, in GHz, of the LNB in the LO1 (Ghz) column. If
it is a single band oscillator, set its frequency, in GHz. You can enter a value in a
range from 0.0 to 15.0 GHz. This value must be lower than the value for LO2.
14 For RF1, RF2, RF3, and/or RF4, set the higher oscillator frequency, in GHz, of the
LNB in the LO1 (Ghx) and LO2 (Ghz) columns. If it is a single band oscillator,
set this value to 0.0. You can enter a value in a range from 0.0 to 15.0 GHz. This
value must be higher than the value for LO1. In single-band LNB applications,
set this value to 0.0.

142 OL-31980-01
Setting up Input Information

15 In the Crossover field, enter the crossover frequency for RF1, RF2, RF3, and/or
RF4. This is an internal threshold frequency used for selecting the LO1 or LO2
frequency, depending on the current downlink frequency settings. This option is
only used in dual-band LNB applications.
You can enter a value in a range from 0.0 to 15.0 GHz. In single-band LNB
applications, set this value to 0.0.
16 From the Polarisation drop-down list, choose the signal polarisation setting
(Horizontal, Vertical, or Automatic). This setting is only applicable when the
LNB Power is set to H-NIT or V-NIT. It marks the polarity of the signal
connected to the current RF input.
17 In the Orbital Posn field, enter the orbital position for RF1, RF2, RF3, and/or
RF4, in degrees. This is the location in orbit of the satellite currently being used.
The satellite position (in degrees) in combination with the direction (either E
(East) or W (West)) denotes the satellite position the dish connected to the
current RF Input should point. This is used when the satellite is not available in
the look-up menu list.
For manual configuration, enter the location of the satellite using the numerical
keypad. The receiver will not recognize the satellite name and identify it as
Unknown. This setting is required to resolve any ambiguity between RF inputs
during automatic disaster recovery.
18 From the East/West Flag drop-down list, choose the east/west flag for RF1, RF2,
RF3, or RF4. This is the satellite position the dish connected to the current RF
Input should point. The options are East, West, or N/A (Not Applicable).
19 Click Apply.
If a disaster recovery is in progress, a message is displayed, recommending that
you do not apply the setup changes during a disaster recovery.

Click Close. If you want to save your changes during a disaster recovery, click
Apply again. The warning message is displayed again. Click OK to confirm your
changes. The changes are saved.

OL-31980 -01 143


Chapter 5 Web GUI Setup and Monitoring

Validating the Orbital Position


Click Validate Orbital Position to validate the RF inputs to match those expected by
the network. The receiver will check to see if all frequencies in the Network
Information Table (NIT) can be tuned to. The Date is displayed as the last date that
the Validate operation was performed.

Reacquiring the Network Information


Click Reacquire to re-acquire the signal using the tuning parameters from user
settings. The Reacquire Network Information window is displayed.

Select Reacquire Tuning & Channel List Only for the decoder to tune back to the
user configured input and frequency and re-acquire the PSI/SI information back to
the selected channel. Click OK.
Note: This operation can take several minutes, depending on the size of the network.

Viewing the Current Input Status


The Current Input Status section displays the current RF status.

The following table describes the Current Input Status information displayed:

Parameter Description

Downlink Frequency The current downlink frequency, in GHz.


(GHz)
L band Frequency (MHz) The current L-Band frequency, in MHz.

Symbol Rate (Msym) Symbol rate of the received signal, in Msymbols/second.

FEC The FEC (Forward Error Correction) rate of the received signal
(N/A, 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 7/8, 8/9 or 9/10).

Modulation Type The modulation type for the received signal (N/A, QPSK, 8PSK,
DVB-S or DVB-S2).

144 OL-31980-01
Setting up Input Information

Parameter Description

Pilots Indicates whether a Pilot is present for the received signal. The
Pilot is set on the modulator for input signal synchronization
purposes.

I/Q The IQ (Input Signal Inversion) for the received signal (Inv or
NonInv).

Signal Status Indicates whether the input signal is locked.

 Locked - Indicates the transcoder is locked to a carrier


with no valid content.

 Lock+Sig - Indicates the transcoder is locked to a


carrier with valid content.

 No Lock - Indicates the transcoder is not locked to a


carrier.
TS ID The Transport ID (in the range from 1 to 65535).

Input The active input port receiving the signal (RF1, RF2, RF3, RF4, or
ASI).

Acquisition State Displays Full if the ASI and PSI tables have all been found.
Otherwise, it will display Degraded if there are missing tables or
None if no ASI or PSI tables have been found.

Orbital Validation Displays the last date that the Validate Orbital Position
operation was performed.

OL-31980 -01 145


Chapter 5 Web GUI Setup and Monitoring

Setting up the ASI Input


1 From the user interface of the D9859, choose Input > Input Setup. The Input
Setup page is displayed.
2 Click ASI.

3 Check the Use ASI Input check box to tune to the ASI input.
Note: Setting a new input to be active will deactivate the currently active input.
4 Click Apply.

Viewing the ASI Input Status


The ASI Input Status table displays the current ASI status. The following table
describes the ASI Input Status information displayed:

Parameter Description

Active Input Indicates the currently selected input source (RF1, RF2, RF3,
RF4, or ASI).

Signal Status Indicates whether the input signal is locked.

 Locked - Indicates the transcoder is locked to a carrier


with no valid content.
 Lock+Sig - Indicates the transcoder is locked to a
carrier with valid content.
 No Lock - Indicates the transcoder is not locked to a
carrier.
Input Rate (Mbps) Displays the bit rate of the input transport stream, in Mbps.

146 OL-31980-01
Setting up Input Information

Parameter Description

ASI Link Indicates whether there is a transport stream link error (Error,
Ok, or N/A).

ASI Transport Indicates the current transport synchronization status (Error,


Ok, or N/A).

ASI Packet Size (bytes) Indicates the packet size (in bytes) for the ASI input (188, 204,
or N/A).

Acquisition State Displays Full if the ASI and PSI tables have all been found.
Otherwise, it will display Degraded if there are missing tables
or None if no ASI or PSI tables have been found.

TS ID The Transport ID (in the range from 1 to 65535).

OL-31980 -01 147


Chapter 5 Web GUI Setup and Monitoring

Setting up SI Receive Parameters


1 From the user interface of the D9859, choose Input > SI Receive Setup. The SI
Receive Setup page is displayed.

2 In the Custom Tuning Mode area, from the Acquisition Mode drop-down list,
choose the tables required for the service list creation and signal acquisition. The
selections are Auto, Basic, or Custom. The default is Basic. If you choose Basic, it
requires NIT to be present. If you choose Auto, it uses all the available service list
tables and it will acquire if any table is present.

148 OL-31980-01
Setting up Input Information

If you choose Custom, click Configure Custom SI Recv and the Configure
Custom SI Recv window opens.

3 From the Frequency Tuning Mode drop-down list, choose the frequency tuning
mode that determines whether to use the NIT to tune to other transports, or to
force the tuning to user configuration settings. Select NIT and the receiver can
change tuning parameters to use all transports available in the NIT. Select User
Cfg to force the receiver to use the user selected tuning parameters.
4 The Service List mode determines which tables are required for tuning.
Rigorous requires all service list tables to be present to acquire the signal.
Degraded requires any service list table to be present to acquire the signal.
5 From the Bouquet Association Table drop-down list, choose Yes to use the NIT
when creating the service list. If set to No, it is view-only. It is not supported in
the current release.
6 From the Network Information Table (NIT) drop-down list, choose Yes to use
the NIT when creating the service list.
7 From the Service Description Table (SDT) drop-down list, choose Yes to use the
SDT when creating the service list.
8 From the Program Association Table (PAT) drop-down list, choose Yes to use
the PAT when creating the service list.
9 Click OK.
10 Enter the Network ID of the uplink signal the receiver is to receive when using
the selected preset. The transcoder's network ID must match the network ID
associated with the transmitted signal that identifies the NIT to be used. You can
enter a value in the range from 1 to 65535. The default is 1.
11 From the CA Mode drop-down list, choose which programs can be viewed via
the transcoder. Choose Std (standard) for PowerVu signal or Open conditional
access for free-to-air (that is, in-the-clear signals). The default is Std.
12 Click Apply.

OL-31980 -01 149


Chapter 5 Web GUI Setup and Monitoring

If a disaster recovery is in progress, a message is displayed, recommending that


you do not apply the setup changes during a disaster recovery.

Click Close. If you want to save your changes during a disaster recovery, click
Apply again. The warning message is displayed again. Click OK to confirm your
changes. The changes are saved.
The SI Receive Status area displays all the current SI Receive settings. It also
displays the source of last tuning and the last Preset Number activated. The
Service List From area displays the current settings of the allowed services (BAT,
NIT, SDT, PAT).

150 OL-31980-01
Setting up Input Information

Setting up Muting Threshold Controls


1 From the user interface of the D9859, choose Input > Muting Thresholds. The
Muting Thresholds page is displayed.

2 Check the Enable Threshold Muting check box to mute the transport stream and
audio in the event of an unstable, poor, or loss of signal condition. The default is
selected.
3 The Transport Mute field for both DVB-S C/N Margin (dB) and DVB-S2 C/N
Margin (dB) sets the DVB-S and DVB-S2 Carrier to Noise margins, in dB, below
the transport outputs that will be muted. The receiver uses these thresholds to
determine when to mute the transport in the event of a noisy, poor, or loss of
signal condition. The adjustable operating range is from -30.0 to 30.0 dB. This
setting must be below the respective Restore value. The default setting is 0.0.
Note: The Enable Threshold Muting check box must be checked for these
settings to be active.
4 The Transport Restore field for both DVB-S C/N Margin (dB) and DVB-S2 C/N
Margin (dB) sets the DVB-S and DVB-S2 Carrier to Noise margins, in dB, above
the transport outputs that will be muted. The receiver uses these thresholds to
determine when to restore the transport after it has been muted. The adjustable
operating range is from -30.0 to 30.0 dB. This setting must be above the
respective Mute value. The default setting is 0.1.
Note: The Enable Threshold Muting check box must be checked for these
settings to be active.

OL-31980 -01 151


Chapter 5 Web GUI Setup and Monitoring

The following displays the Transport Default C/N Margin Relationship:

Transport Muted
0.0 Transport Mute

Transport
C/N Margin

0.1 Transport Restore

Transport Restored

5 The Audio Mute field for both DVB-S C/N Margin (dB) and DVB-S2 C/N
Margin (dB) sets the DVB-S and DVB-S2 Carrier to Noise margins, in dB, below
the audio outputs that will be muted. The receiver uses these thresholds to
determine when to mute the audio in the event of a noisy, poor, or loss of signal
condition. The adjustable operating range is -30.0 to 30.0 dB. This setting must be
below the respective Restore value. The default setting is 0.0.
Note: The Enable Threshold Muting check box must be selected for these
settings to be active.
6 The Audio Restore field for both DVB-S C/N Margin (dB) and DVB-S2 C/N
Margin (dB) sets the DVB-S and DVB-S2 Carrier to Noise margins, in dB, above
the audio outputs that will be restored. The receiver uses these thresholds to
determine when to restore the audio after it has been muted. The adjustable
operating range is from -30.0 to 30.0 dB. This setting must be below the
respective Mute value. The default setting is 0.1.
Note: The Enable Threshold Muting check box must be selected for these
settings to be active.
The following displays the Audio Default C/N Margin Relationship:

Audio Muted
0.0 Audio Mute

Audio
C/N Margin

0.1 Audio Restore

Audio Restored

7 Click Apply.

152 OL-31980-01
Setting up Input Information

Viewing the Input Status


From the user interface of the D9859, choose Input > Input Status. The Input Status
page is displayed.

The Current Input Status area displays the same information shown in the Input
Setup page. For more information on the parameters displayed, see Setting up the
RF Input (on page 141).
The Tuner Performance area displays the satellite dish information, such as the C/N
Margin and Signal Level.

OL-31980 -01 153


Chapter 5 Web GUI Setup and Monitoring

Configuring the Disaster Recovery Settings


The disaster recovery settings allow you to configure the search path when a disaster
occurs. By default, the disaster recovery feature is enabled. For more information on
disaster recovery, see Disaster Recovery (on page 6).
1 From the user interface of the D9859, choose Input > Disaster Recovery. The
Disaster Recovery Setup page is displayed.

2 From the Enable Disaster Recovery drop-down list, choose to enable or


temporarily disable the disaster recovery feature. Choose Yes (default) to enable
disaster recovery. Choose No to set the disaster recovery into maintenance mode.
It will automatically set the Disaster Recovery back to Yes after five minutes.
This prevents the user from accidentally disabling disaster recovery
permanently. To disable disaster recovery, remove all the disaster recovery
configurations (Search Path settings below).
The maintenance mode allows you to perform any maintenance operations (such
as IP setup), without the unit declaring disaster and initiate a disaster recovery
search path.
Note: Although the default is set to Yes, the disaster recovery is not operational
until the Search Path is configured.

154 OL-31980-01
Setting up Input Information

3 In the Signal Lock Period field, enter the time, in seconds, the unit must wait for
a signal lock before declaring that the signa l is not usable and move on to the
next search location in the search path. You can enter a value in the range from 5
to 255 seconds. The default is 30 seconds.
4 In the Signal Loss Period field, enter the time, in seconds, the unit must wait
(after detecting a signal loss) before declaring a disaster. You can enter a value in
the range from 5 to 2160000 seconds. The default is 30 seconds.
5 In the Signal Verify Period field, enter the time, in seconds, the unit must wait
for the PAT table to verify the signal has a valid transport. You can enter a value
in the range from 10 to 255 seconds. The default is 60 seconds.
6 The Search Path area determines the search order of backup transports when a
disaster occurs. For a list of triggers, see Disaster Recovery (on page 6). During a
disaster, the unit will attempt to tune to the backup transport, based on the
Search Path configured. The table displays the origin and backup channels for
PE1 and PE2.
The Origin column is automatically updated when the RF Input is enabled and
configured. For more information, see Setting up the RF Input (on page 141).
Disaster Recovery supports up to three backups. To configure Backup 1, 2, or 3:
a Click the Backup 1, Backup 2, or Backup 3 radio button.
b Click Edit/Enable. A window is displayed, with tuning parameters.

c For information on the tuning parameters, see Setting up the RF Input (on page 141).
For information on the Net ID field, see Setting up SI Receive Parameters (on page
148).
Note: The RF input in the Input Setup page must be configured to match the
bandwidth of the backup parameters.
d Click OK.

OL-31980 -01 155


Chapter 5 Web GUI Setup and Monitoring

e In the Search Path table, click the field to edit an enabled Backup 1, 2, or 3. The
following is an example of editing the enabled Backup 1 channel for PE1:

f Enter a channel number and click Save. Enter 0 to clear the backup channel.
Note: We recommend that you configure a minimum of one backup transport. If no
backup transports are configured, the origin channel is used.
The configured backup is enabled. To disable a backup, click the Backup 1,
Backup 2, or Backup 3 radio button and click Disable.
7 Click Apply.
If a disaster recovery is in progress, a message is displayed, recommending that
you do not apply the setup changes during a disaster recovery.

Click Close. If you want to save your changes during a disaster recovery, click
Apply again. The warning message is displayed again. Click OK to confirm your
changes. The changes are saved.

156 OL-31980-01
Setting up Input Information

Viewing the Disaster Recovery Status


From the user interface of the D9859, choose Input > Disaster Recovery Status. The
Disaster Recovery Status page is displayed.

The State field displays the current disaster recovery status. The three statuses are:

 No Disaster - The unit is in a normal state.


 D/R In Progress - The unit has detected a loss of input and it is searching for a
backup transport using the configured search path. The configured search path is
displayed in the Backup Transport area.

 D/R Disabled - The disaster recovery feature is temporarily disabled. To enable


disaster recovery, see Configuring the Disaster Recovery Settings (on page 154).

OL-31980 -01 157


Chapter 5 Web GUI Setup and Monitoring

The Backup Transport area displays the tuning parameters of the current origin and
backup transports configured. For example, if only Backup 1 and Backup 3 are
configured, the table will display the tuning parameters for Origin, Backup 1, and
Backup 3. The Configured By row indicates that the backup t ransport is configured
by a user.
The Search Path area displays the channel numbers assigned to the Origin and
Backup transports for PE1 to PE8.

158 OL-31980-01
Setting up Input Information

Setting up the Channel Selections


1 From the user interface of the D9859, choose Input > Channel Selection. The
Channel Selection page is displayed.

2 Enter or select a channel number for up to eight program entries.


3 Click Apply.
If a disaster recovery is in progress, a message is displayed, recommending that
you do not apply the setup changes during a disaster recovery.

Click Close. If you want to save your changes during a disaster recovery, click
Apply again. The warning message is displayed again. Click OK to confirm your
changes. The changes are saved.

OL-31980 -01 159


Chapter 5 Web GUI Setup and Monitoring

Viewing the Channel Status


From the user interface of the D9859, choose Input > Channel Status. The Channel
Status page is displayed.

The following table describes the channel information displayed:

Parameter Description

PE Index Indicates the Program Entry number (PE1 to PE8).

Channel Displays the input channel of the current PE. The channel is
displayed in a range from 1 to 65535.

Channel Name Displays the channel name of the current PE.

Conditional Access Indicates the type of Conditional Access (CA) system used by the
System ID program (SA, BISS, or FTA).

Channel Authorised Indicates whether the transcoder is authorized to receive the


program (Yes or No).

Channel Encrypted Indicates whether the received program is encrypted (Yes or No).

Channel Scrambled Indicates whether the received program is scrambled (Yes or No).

160 OL-31980-01
Setting up Input Information

Parameter Description

SR Status Displays the status of an alternate authorized program/service


from the same transport stream when the transcoder is not
authorized to view the primary program. This is an uplink
initiated function that maps the alternate service to the original
(primary) service PIDs, replacing the original service with the
alternate service at the digital transport output. No local
intervention is required by the transcoder operator for provision
of this service replacement feature. The statuses are Not Started,
Primary, or Alternate.
Not Started - Indicates that an event has not started.
Primary - Indicates that a service replacement event is active, but
the primary program is being displayed.
Alternate - Indicates that a service replacement event is active, and
that the transcoder has tuned to and is displaying the alternate
program/event as it is not authorized to view the scheduled
event.

SR Type Indicates the type of service replacement event. The types are
None, Scheduled, CA, Cue Trigger
None - Indicates that no service replacement event is scheduled.
Scheduled - Indicates that all transcoders will tune to the alternate
program at the scheduled time. This status applies to PE1 to PE8.
CA - Indicates that only transcoders unauthorized to view the
scheduled program will tune to the alternate program according
to the selected authorization tier bits. This status applies to PE1 to
PE8.
Cue Trigger - Indicates that only transcoders authorized by the
Cue Trigger mask will tune to the scheduled program/event.
Note: The Cue Trigger service replacement event type is not
supported in the current release.

SR Start/End Time Displays the start/end time of the service replacement event when
one is scheduled; otherwise, the default start/end time is
displayed. The default start/end time is 2007/09/01 00:00:00.

OL-31980 -01 161


Chapter 5 Web GUI Setup and Monitoring

Viewing the CA Status


From the user interface of the D9859, choose Input > CA Status. The CA Status page
is displayed.

The following describes the columns in the CA Status table:

Status Description

Index The ISE number.

ISE User Address The ISE User Address. It is a 11 digit address in the following
format: ###-###-####-#.

ISE Version Number The ISE version number. It consists of 7 characters.

Enc Data pkts passed Indicates the number of encrypted Addressable Data Packets
successfully processed. Ideally, the ADP Enc Pass and ADP Enc
Total numbers should be identical.

Enc Data pkts recvd Indicates the number of encrypted Addressable Data Packets
received. Ideally, the ADP Enc Pass and ADP Enc Total
numbers should be identical.

Non-Enc Data pkts passed Indicates the number of non-encrypted Addressed Data
Packets successfully processed. Ideally, the ADP Enc Pass and
ADP Enc Total numbers should be identical.

Non-Enc Data pkts recvd Indicates the total number of non-encrypted Addressable Data
Packets received. Ideally, the ADP Non-Enc Pass and ADP
Non-Enc Total numbers should be identical.

162 OL-31980-01
Setting up Input Information

Setting up the BISS Mode


1 From the user interface of the D9859, choose Input > BISS. The BISS page is
displayed.

2 From the BISS Mode drop-down list, choose the Basic Interoperable Scrambling
System for the transcoder (Mode 1 or Mode E). All channels assigned to the PE
identified as BISS CA-controlled in the PMT will be decrypted.
3 If you selected BISS Mode 1, enter a fixed 12-character BISS mode session word
in the BISS Mode-1 Session Word field. Once entered it cannot be viewed and it
is only displayed as asterisks (*). Contact your program provider for the session
word.
4 If you selected BISS Mode E, enter the 16-character BISS Mode-E encrypted
session word in the BISS Mode-E Encrypted Session Word field and the 14-
character BISS Mode-E injected ID in the BISS Mode-E Injected ID field. Once
entered, neither of these values can be viewed and it is only disp layed as
asterisks. Contact your program provider for the respective session word and/or
injected ID.
5 Click Apply.

OL-31980 -01 163


Chapter 5 Web GUI Setup and Monitoring

Viewing the PSI Tables


From the user interface of the D9859, choose Input > PSI Tables. The PSI Tables
page is displayed.

You cannot make any changes in the PSI table and can only view the PSI tables
received and their settings. The following is a list of the various columns:

Abbreviation Description

Table Type Indicates the MPEG table acronym.

PAT, CAT, PMT, TSDT, NIT, NIT Other, SDT, SDT Other,
BAT, AEIT P/F, OEIT P/F, TDT, RST, ST, TOT, DIT, SIT,
ECM Odd, ECM Even, EMM, MPE, DPI, DRT, CDT, MCT,
MIT, MAT, ECT, or Invalid Table ID

Table ID Extension Displays the MPEG/DVB Table ID.

Status Indicates the reception status of the table.

None, Partial, Full, Update, Timeout, or Lost


Version Indicates the table version number.

PID Indicates the value of the PID on which the table is present.

Number of Sections Indicates the number of sections in the table.

164 OL-31980-01
Setting up Input Information

Viewing PSI Frequency Information


From the user interface of the D9859, choose Input > PSI Frequency. The PSI
Frequency page is displayed.

You cannot make any changes in the PSI Frequency table and can only view the
available frequency plans stored in the transcoder. The following is a list of the
various columns:

Abbreviation Description

Transport Stream ID Displays the transport ID.

Frequency (GHz) Displays the downlink frequency, in GHz (0.0 to 15.0 GHz).

Symbol Rate (MSym) Displays the symbol rate, in Mbps.

Orbital Position Displays the orbital position of the satellite, in degrees


(East of West).
Polarization Displays the polarity of the received signal (H,V, or Off).

Flag Displays the satellite position (in degrees), in combination


with the direction (East or West).

FEC Indicates the Forward Error Correction inner code rate


(1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 7/8, 8/9, or 9/10).

RF Modulation Indicates the modulation of the signal (QPSK DVB-S, QPSK


DVB-S2, 8PSK DVB-S2 or 16QAM DVB-S2).

Network ID Displays the original network ID.

OL-31980 -01 165


Chapter 5 Web GUI Setup and Monitoring

Viewing the PSI Channels


From the user interface of the D9859, choose Input > PSI Channel. The PSI Channel
page is displayed.

You cannot make any changes in the PSI Channel table and can only view the
available channels and their settings. The following is a list of the various columns:

Abbreviation Description

Service ID Indicates the virtual channel number.

TS ID Displays the identification number of the transport on


which the channel is available. For more information on the
transport streams, see Viewing PSI Frequency Information
(on page 165).

Program Name Indicates the name of the channel.

PMT PID Indicates the PID of the channel's Program Map Table.

ECM PID Indicates the PID of the channel's Entitlement Control


Message stream.

166 OL-31980-01
Setting up Input Information

Viewing the PID Input Status


From the user interface of the D9859, choose Input > PID Input Status. The PID
Input Status page is displayed.

You cannot make any changes in the PID Input Status table and can only view the
available channels and their settings. The following is a list of the various columns:

Abbreviation Description

PE Index Indicates the Program Entry number (PE1 to PE8).

Type Name assigned to the Program Entry, up to 4 alphanumeric characters.

Detail Displays any detail associated with the program PID (e.g., MPG2 PID).
The parameters are: MPG1 VID, MPG2 VID, 422 VID, H264 VID, HD VID,
MPG4 VID, MPG AUD, MPG2 AUD, DVB AC3, DVB DDP, AAC AUD,
HEAAC, AUD, MPG4 AUD, DBE AUD, DTS AUD, DVB TXT, DVB VBI,
DVB SUBT, DVB ASYN, DVB SYNS, DVB SYND, DVB MPE, DVB DCAR,
DVB OCAR, SA VBI, ATSC AC3, ATSC DDP, SA UTLD, SCTE DPI, SA
HSD, SA CDDL, SA WBD, SA SUBT, ECM, EMM, PCR, or UNKNOWN.

Language Displays the language code carried in the PMT for the current PID, if
applicable. The supported languages are according to ISO 639-2 Language
Codes.
PID The program PID number, in the range from 1 to 8192.

Present Indicates whether the PID is present in the incoming stream.

OL-31980 -01 167


Chapter 5 Web GUI Setup and Monitoring

Setting up Audio and Video Information


Setting up the Video Parameters
1 From the user interface of the D9859, choose Audio & Video > Video Decoding.
The Video Setup page is displayed.

2 From the Primary Video Output drop-down list, choose the format for local
decoding. The options are Auto, HD 720p, HD 1080i, or SD.
3 From the Standard Definition Output drop-down list, choose the actual
standard definition output format of the primary video if the PV Output is set to
SD. The options are Auto, NTSC, PAL-N (AR), PAL-M, or PAL-B/G/I/D. You
must use NTSC for 525-line systems and PAL-B/G/I/D for 625-line systems.
4 From the Standard Definition Aspect Ratio drop-down list, choose the Standard
Definition aspect ratio of your TV monitor (4:3 or 16:9). The default is 4:3. Set it to
the corresponding value.
5 From the Selected Aspect Ratio Conversion drop-down list, choose the aspect
ratio conversion that the transcoder will perform on the incoming signal for the
picture to be displayed correctly on your TV, based on the Standard Definition
Aspect Ratio selection.
The options are None, Auto, Auto AFD, 16:9 L/B, 4:3 P/B, 14:9, 4:3 CCO, and
16:9 Scale. The default is Auto.
6 From the the Wide Screen Signalling drop-down list, choose the wide screen
signaling output mode. It is used to select how the transcoder affects PAL WSS
when it is present in the VBI line 23. The table below describes each of the
options. The default is Auto.

168 OL-31980-01
Setting up Audio and Video Information

WSS Mode Description

Passthrough Passes WSS unmodified as received by the transcoder.

Auto:Create Creates WSS to output the correct aspect ratio when performing
aspect ratio conversion.

Auto:Modify If WSS is present in the input stream, it is modified to output the


correct aspect ratio when performing aspect ratio conversion. If
WSS is not present in the input, no WSS will be present in the
output.

Suppress Removes WSS output.


7 Check the Enable Banner Display check box to display alarms and warnings on
the on-screen display (e.g., TV monitor).
8 Click Apply.

Viewing the Video Status


The Video Status area displays the current video settings, and the encoding, bit rate,
FPS and aspect ratio of the incoming signal. The fields are read -only. The following
table describes the video status information displayed:

Video Status Description

Primary Video Indicates the actual output video format (Auto, HD 720p, HD 1080i,
Output or SD).

Standard Definition Displays the actual standard definition format of the primary video
Output output if the PV Output is set to SD.

Aspect Ratio Displays the standard definition aspect ratio of your TV monitor.

Wide Screen Displays the Wide Screen Signaling output mode.


Signalling

Video Input Format Displays the video encoding, format, and resolution of the received
program.

Encoding Format The input stream type of the received signal/program.

Bit Rate (Mbps) Indicates the bit rate of the input video stream, in Mbps.

Frame Rate (fps) Indicates the frame rate of the input video stream.
3:2 Pulldown Indicates whether 3:2 pulldown is detected, was recently detected,
or not detected in the input video stream (Yes, Recent, or No).

OL-31980 -01 169


Chapter 5 Web GUI Setup and Monitoring

Setting up Captions
1 From the user interface of the D9859, choose Audio & Video > Captions. The
Captions page is displayed.

2 From the Preferred Closed Caption Mode drop-down list, choose the type of
closed captioning to use if there are multiple available in the stream (Auto, SA
Custom, EIA 708, Type 3, Type 4 SA, Type 4 ATSC, Reserved, or DVS 157). The
default is Auto.
Note: SA Custom is not supported when telecine video coding is enabled.
3 The Closed Caption Mode in the Status area displays the actual closed caption
mode in the output. This is read-only.
4 Click Apply.

170 OL-31980-01
Setting up Audio and Video Information

Setting up Subtitles
1 From the user interface of the D9859, choose Audio & Video > Subtitles. The
Subtitles page is displayed.

2 Select the Subtitle Control to use to display the program subtitles. The following
table describes each of the available options:

Op Mode Selection Description

Off No subtitles are displayed.

On Displays DVB or Imitext subtitles, if available.

DVB Displays only DVB titles, if available. Otherwise, no subtitles are


displayed.

Imitext Displays only Imitext subtitles, if available. Otherwise, no subtitles


are displayed.
3 From the Imitext Position drop-down list, choose the position of the on-screen
subtitle text (Standard or Extended).
4 From the Imitext Foreground Color drop-down list, choose the color for Imitext
subtitles. Auto displays text in the color transmitted by the subtitling equipment.
Yellow and White overrides the color set by the uplink and display text in the
selected color.
5 The Imitext Background Color sets the text background for Imitext subtitles. The
following table identifies the affect each setting has on the displayed subtitle text:

BackGnd Option Description

Auto Uses the uplink subtitling equipment setting.

OL-31980 -01 171


Chapter 5 Web GUI Setup and Monitoring

BackGnd Option Description

Shadow Applies an outline to the right side of each text character. No


background box is applied to subtitles, i.e., text is visible directly on
top of video.
Opaque Applies a black box to each text character.

Semi Applies a semi-transparent box to subtitle text.

None No shadow or outline is applied to subtitle text.


6 In the Subtitle Language Settings area, click on the radio button of the input
source for the subtitle language. The default is Language List. Language Entry
and PMT Order are more applicable for advanced applications. The following
table describes each of the available options and how to set them:

Select Language By Option Description

Language List Select the MPEG language to display from the available list.
The following are the available options:
ara (Arabic), btk (Batak (Indonesia), ben (Bengali), bul
(Bulgarian), chi (Chinese), cze (Czech), dan (Danish), dut
(Dutch), eng (English), fin (Finnish), fre (French), ger
(German), gre (Greek), heb (Hebrew), hin (Hindi), hun
(Hungarian), ice (Icelandic), ind (Indonesian), ita (Italian),
jpn (Japanese), kor (Korean), may (Malay), mul (Multiple
Languages), nor (Norwegian), per (Persian), pol (Polish),
por (Portuguese), rum (Romanian), rus (Russian), san
(Sanskrit), scc (Serbian), sin (Sinhalese), slo (Slovak), som
(Somali), spa (Spanish), swe (Swedish), tai (Tai Other), tam
(Tamil), tha (Thai), tur (Turkish), ukr (Ukrainian), or vie
(Vietnamese)

Language Entry Enter the three-character code provided by your uplink


service provider (e.g., eng for English).
The supported languages are according to ISO 639-2
Language Codes.

PMT Order Select the subtitle PID entry to display (First to Eighth). This
information is available from your uplink provider.
7 Click Apply.

172 OL-31980-01
Setting up Audio and Video Information

Setting up VBI
1 From the user interface of the D9859, choose Audio & Video > VBI. The VBI
page is displayed.

2 Check the Enable VITS PAL Line 17, 18, 330, and/or 331 check boxes to enable
the Vertical Interval Test Signal (VITS) on PAL Lines 17, 18, 330, and/or 331.
3 Click Apply.

OL-31980 -01 173


Chapter 5 Web GUI Setup and Monitoring

Setting up Audio Parameters


1 From the user interface of the D9859, choose Audio & Video > Audio Decoding.
The Audio Decoding page is displayed.

2 The Audio Selection area allows you to select the audio PID for audio decoding.
The D9859 supports two local audio devices.
a From the Select By drop-down list, choose the input source for Audio 1 or
Audio 2.
Note: You cannot select PMT order for one audio and Language List or
Language Entry for the other audio. For example, you cannot select PMT
Order for Audio 1 and Language List for Audio 2.
b If Language List is selected, you must choose a language from the Language
List column. If Language Entry is selected, you must a language code in the
Manual Entry column. If the languages selected are different, the first PID
with the matching language will play on the appropriate audio device
(Audio 1 or Audio 2). If you select the same language for both Audio 1 and
Audio 2, the PIDs are mapped as follows: the first matching language PID to
Audio 1 and the second matching PID to Audio 2.

174 OL-31980-01
Setting up Audio and Video Information

c If PMT Order is selected, you must set the PMT order for each audio (None,
AUD1 to AUD64). You cannot select the same PID for both audio devices. If
you select the same instance of an audio PID for one of the audio devices, the
other audio device PID instance will automatically increment by one. For
example, Audio 1 is set to AUD1 and Audio 2 is set to AUD2. If you change
Audio 1 source to AUD2, the Audio 2 source will automatically change to
AUD3 to resolve the conflict.
3 There are two audio settings. The Audio Setup area allows you to configure the
two balanced audio outputs on the rear panel (Audio 1 and Audio 2), known in
the Web GUI as 1 and 2, respectively.
a From the Audio Mode drop-down list, choose the output mixing.
Select Stereo (Left and Right are passed directly through to Left and Right),
R-Mono (Right is passed to both the Left and Right), L-MONO (Left is passed
to both the Left and Right), or Mixed (Left is passed to both the Left and
Right, and Right is passed to both the Left and Right).
b From the AC3 Compression drop-down list, choose the mode to use if the
output is compressed Dolby Digital audio. The selections are Line Mode,
Custom 1, Custom 0 or RF Mode. RF Mode is recommended for analog cable
modulators.
c From the Left Attenuation drop-down list, choose the volume adjustment for
the Left audio channel. You can select a value in the range from -6.0 dB to
+6.0 dB, in increments of 0.5 dB.
d From the Right Attenuation drop-down list, choose the volume adjustment
for the Right audio channel. You can select a value in the range from -6.0 dB
to +6.0 dB, in increments of 0.5 dB.
4 Click Apply.

Viewing the Audio Status and Audio PIDs


The Audio Status area displays the current audio settings. The following table
describes the audio status information:

Audio Status Description

Audio Displays the current audio deocder status.

PID Indicates the program PID number (1 to 8191).

Language Indicates the language code.

Format Indicates the format of the audio input stream.

Bit Rate (kbps) Displays the bit rate of the audio input stream, in kbps.

SFR Displays the sample rate of the input audio stream, in kHz (32, 44.1,
or 48 KHz).

Buffer Indicates the buffer level of the input audio stream, in bytes.

OL-31980 -01 175


Chapter 5 Web GUI Setup and Monitoring

Audio Status Description

DDP Mode Displays the presence of Dolby Digital Plus frames within a Dolby
Digital audio stream (ON or OFF).
Dualmono Mode Indicates the presence of dual mono audio outputs in the audio
stream (ON or OFF).

Click List Audio PIDs to view a list of all the current audio PIDs.

The following table describes the Audio PIDs information:

Audio Status Description

Type Displays the input audio source (AUD1 or AUD2)

Detail Indicates any detail associated with the audio PID. The parameters
are: MPG1 VID, MPG2 VID, 422 VID, H264 VID, HD VID, MPG4
VID, MPG AUD, MPG2 AUD, DVB AC3, DVB DDP, AAC AUD,
HEAAC, AUD, MPG4 AUD, DBE AUD, DTS AUD, DVB TXT, DVB
VBI, DVB SUBT, DVB ASYN, DVB SYNS, DVB SYND, DVB MPE,
DVB DCAR, DVB OCAR, SA VBI, ATSC AC3, ATSC DDP, SA
UTLD, SCTE DPI, SA HSD, SA CDDL, SA WBD, SA SUBT, ECM,
EMM, PCR, or UNKNOWN.

Language Displays the language code of the audio PID, if applicable.

PID Indicates the audio PID number, in the range from 1 to 8192.

Present Indicates whether the audio PID is present in the incoming stream
(Yes or No).

176 OL-31980-01
Setting up Audio and Video Information

Setting up Cueing Parameters


1 From the user interface of the D9859, choose Audio & Video > Cueing. The
Cueing page is displayed.

2 From the Cueing Mode drop-down list, choose whether the cueing output
should be DTMF tones or trigger pins.
Tones are standard Dual-Tone Multi-Frequency (DTMF) tones. The tones are
generated at the Cue Tone/Relay output on the rear panel of the transcoder.
Trigger refers to open-collector pins which can be generated at the Cue
Tone/Relay output on the rear panel of the transcoder.
3 If Trigger is selected as the Cueing Mode, choose the pin polarity from the
Trigger Polarity drop-down list. Choose High for the pins to act as open or
floating collectors on an active cueing signal and as ground on an inactive signal.
Choose Low for the pins to act as ground on an active cueing signal and as open
or floating collectors on an inactive signal.
4 If the Cueing Mode is set to Tone, set the number of consecutive tone sequences
to be generated in the Cueing Tone Repeat Count field. Values greater than 1
are provided when a scenario demands repetition to ensure that the ad insertion
equipment receives the signal. You can enter 1, 2, or 3. The default is 3.
5 If the Cueing Mode is set to Tone, enter the Tone Duration of each tone, in
milliseconds, in the range from 0 to 80. The default is 40.
6 If the Cueing Mode is set to Tone, enter the Silence Duration of each silence
between tones, in milliseconds. The duration is in the range from 0 to 80. The
default is 40.
7 From the Relay Mode drop-down list, choose the relay mode that can be
programmed to respond to an Alarm state, Warning statue, or the state of one of
the eight cue trigger pins. The response is generated at the Cue Tone/Relay
output on the rear panel of the transcoder. The following table shows what the
possible field settings are and their relationship to the transcoder output:

OL-31980 -01 177


Chapter 5 Web GUI Setup and Monitoring

Relay Mode Condition Relay Contact

NC - C C-NO
Alarm Unit Power Off Open Close

Alarm State Open Close

No Alarm Close Open

Trigger Active (selected in PNC) Close Open


Inactive Open Close
8 If the Relay Mode is set to Trigger, choose the cue trigger bit/pin that will
activate the relay from the Relay Trigger Bit drop-down list (1 to 8).
9 Click Apply.

178 OL-31980-01
Setting up Audio and Video Information

Setting up Cue Tone Test


1 From the user interface of the D9859, choose Audio & Video > Cue Tone Test.
The Cue Tone Test page is displayed.

2 In the Test Tones field, specify the three digit tone sequence. You can enter a
value between 000 and 999.
3 From the Sequence Mode drop-down list, choose the tone sequence mode. The
following describes the available options:

- * - Start tone only


- # - End tone only

- */# - Start and end tones. The end tone is signaled after waiting the time
specified in Delay(sec).
4 Click Apply.

OL-31980 -01 179


Chapter 5 Web GUI Setup and Monitoring

Setting up Cue Tones


1 From the user interface of the D9859, choose Audio & Video > Cue Tone. The
Cue Tone page is displayed.

2 The Sequence Number lists the tone sequences. The transcoder supports up to
16 tone sequences. You can configure the state, tones, mode, and delay for each
tone sequence.
3 From the Sequence State drop-down list, choose to enable or disable the current
tone sequence. When disabled, no cue tone is output.
4 In the Sequence Tones field, set the three digit tone sequence (1 to 999).
5 From the Sequence Mode drop-down list, choose the tone sequence mode.
Select * for start tone, # for the end tone, and */# for the start and end tones. The
end tone is signaled after waiting the time specified in the Sequence Delay field.
6 If the Sequence Mode is set to */# (Start/Stop), set the sequence delay in the
Sequence Delay field, in seconds, between the start and stop sequences. You can
enter a value in the range from 1 to 255. The default is 30.
7 Click Apply.

180 OL-31980-01
Setting up Audio and Video Information

Setting up Services
1 From the user interface of the D9859, choose Audio & Video > Decode Enables.
The Decode Enables page is displayed.

2 Check the services to be decoded by the transcoder. Check or uncheck Enable


Decode Engine check box to select/de-select all the services in the list.
3 Click Apply.

OL-31980 -01 181


Chapter 5 Web GUI Setup and Monitoring

Configuring Transport Stream Information


Configuring the ASI Output
1 From the user interface of the D9859, choose Transport Stream > ASI Output.
The ASI Outputs page is displayed.
Note: After you make any changes, a successfully updated (session open)
message appears. The changes are displayed, but not saved. You must click
Apply to save and apply the changes.

Note: Any changes made to the ASI DPM values will automatically change the
Mode Status to Edited by User.
2 From the Rate Control drop-down list, choose the output rate control. The
following table describes the affect each of the settings has on the output bit rate:

Rate Control Description


Auto The output rate follows that set by the uplink. The output rate will
be the same as the input rate (including all null packets). This
means the output bit rate is determined automatically based on
the input source symbol rate and FEC value.

182 OL-31980-01
Configuring Transport Stream Information

Rate Control Description

User The output rate is specified by the User Rate field. It is determined
by the user setting regardless of the input source.
3 If the Rate Control is set to User, enter the maximum output bit rate in the User
Rate field. This setting is used when the signal source is RF or ASI and allows
you to set the output bit rate to a value expected by equipment connected to the
ASI output.
You can enter a range from 0 to 206 Mbps.
Note: Output data may be lost if this bit rate is set to a value less than the actual
signal bit rate.
4 From the Output Mode drop-down list, choose the DPM output mode for the
current output. With the exception of No Output and Full DPM Control,
selecting a mode will configure the DPM settings to achieve the specified
behavior. In this way, they act as DPM presets. The Mode Status is changed
from Unmodified to Edited by User. We highly recommend that you use either
one of these basic modes, or, for advanced setup, enter the DPM mapping before
setting the Output Mode. The following table describes each mode:

Output Mode Description

No Output No ASI output will be generated and the ASI port will be disabled.

Passthrough All PEs will be set to Pass and other DPM settings will also be set.

Service Channels This is similar to Passthrough, except that only channels applied
Only to program entries are available on the output.
MAP Passthrough The output will be identical to the input, except that channels
assigned to PEs and PIDs will be mapped using the DPM settings.
If the input is tuned to a valid channel, the PEs are automatically
set to Map. Otherwise, the PEs are automatically set to Drop.
Note: If the PE is mapped, it uses the last saved output MAP
configuration. The output map (for example, output channel PMT)
does not change automatically if the input or channel number is
changed.
MAP Service This is similar to MAP Passthrough, except that only channels
Channels Only applied to program entries are available on the output. If the input
is tuned to a valid channel, the PEs are automatically set to Map.
Otherwise, the PEs are automatically set to Drop.
Note: If the PE is mapped, it uses the last valid input. The output
map (for example, output channel PMT) does not change
automatically if the input or channel number is changed.

Full DPM Control The output will be generated according to the DPM settings on the
ASI Digital Program Mapping page. This is a manual control
setting.

OL-31980 -01 183


Chapter 5 Web GUI Setup and Monitoring

Output Mode Description

Transcoding The output will be generated using the DPM MAP settings, except
that the DPM Action will be set to XCode and the Descrambled
mode will be set to Descrambled. If the input is tuned to a valid
channel, the PEs are automatically set to XCode. Otherwise, the
PEs are automatically set to Drop.
Note: If the PE is transcoded, it uses the last valid input. The
output map (for example, output channel PMT) does not change
automatically if the input or channel number is changed.
A message appears to confirm that you want to resynchronize the output
changes and PIDs to match the selected input programs. Click Yes.
If a conflict occurs and Enable Auto Map for Collision is set to No, a detailed list
of all the conflicts is displayed in the Output Channel and PID Conflicts table
when you click View Conflicts. You can then resolve the conflicts manually. If a
conflict occurs and Enable Auto Map for Collision is set to Yes, a message that
the conflicts will be fixed automatically and the Output Channel and PID
Conflicts table is empty.

 For channel conflicts, the system will only automatically change the
duplicated output channel numbers. If both PE actions are set to Map or
XCode, the output channel number of the higher PE is changed. Otherwise,
the output channel number of the mapped and transcoded PE is changed.
The new channel number selected is the next channel number that does not
appear in the current PAT or belong to any other PEs.
 For PID conflicts, the system will only automatically change the duplicated
output PID numbers. If both PE actions are set to Map or XCode, the output
PID number of the higher PE is changed. Otherwise, the output PID number
of the mapped or transcoded PE is changed. For exa mple, if the PMT PID of
PE1 matches the ES PID of PE2, the ES PID of PE2 is changed. The new PID
number selected is the next number that does not appear in the output of any
PE and it is not in the current transport input.
Click Apply to save the resolved conflict changes.
5 The Mode Status field indicates the current DPM configuration change by a user
after changing the Output Mode. The following is a list of possible statuses:

184 OL-31980-01
Configuring Transport Stream Information

Mode Status Description

Unmodified No changes were made after setting a new Output Mode.

Edited by User DPM changes were made.

Auto Re-Mapped The output map changed automatically to fix the output channel
or PID conflicts at the time of setup.

Changed by Uplink DPM output changes were initiated by an encoder.


6 From the Descrambled drop-down list, choose whether the output will be
descrambled if the input is scrambled. The following table describes the available
options:

Descramble Description

Scrambled The output channel will remain scrambled even if the PE is


authorized and can descramble the channel.
Descrambled Descrambles the output channel, and passes in-the-clear channels.
7 Choose Yes to insert null packets into the output to maintain output at a constant
bit rate from the Null Packet Insertion drop-down list. Otherwise, choose No.
Note: We recommend that you set the Null Packet Insertion to Yes, especially if
the Output Mode is set to Transcoding.
8 Click Apply.

Setting Up the ASI Auto Synchronization Options


The ASI Auto Sync area allows you to configure the DPM without editing each
output channel and PID separately.
1 In the ASI Outputs page (Transport Stream > ASI Output), refer to the ASI
Auto Sync area.
2 From the Enable Auto Fix for Collision drop-down list, choose Yes for the DPM
to resolve channel and PID collisions automatically on the transport outputs.
New values are assigned to the parameters that caused the conflict. The new
assigned values are not used by any incoming transport or other PE outputs. If a
collision is detected, you can review the new changes and click Apply to accept
the new changes.
Choose No and a detailed list of all the conflicts is displayed in the Output
Channel and PID Conflicts table (click View Conflicts) when a conflict occurs.
You can then resolve the conflicts manually.

OL-31980 -01 185


Chapter 5 Web GUI Setup and Monitoring

3 From the Enable Fixed Output drop-down list, choose Yes for the DPM to assign
new values for all the output channels and PIDs according to the Fixed Output
Options table when you Resynchronize All. Click Fixed Output Option to
configure the ASI Fixed Output Options:

a From the Use Input Channel Numbers drop-down list, choose Yes to use the
output channel. Otherwise, choose No (default) to use the first channel and
channel offset assigned below.
i In the First Channel Number field, enter the first PE channel number to
use. By default, the channel is set to 1.
ii In the Channel Numbers Offset field, enter the subsequent PE channel
numbers. For example, if the First Channel Number is set to 100 and the
Channel Numbers Offset is set to 10, then the first channel number is 100,
and the second channel number is 110.
b From the Use Input PMT PID Numbers drop-down list, choose Yes to use
the input PMT PID number. Otherwise, choose No (default) to use the first
PE PID number and PID offset number assigned below.
i In the First Channel First ES PID Number field, enter the first PE PMT
PID number. The default is 1701.
ii In the PMT PID Numbers Offset field, enter the offset of the subsequent
PE PMT PID numbers. For example, if the First Channel First ES PID
Number is set to 1701 and the PMT PID Numbers Offset is set to 1, then
the first PMT PID number is 1701, and the second PMT PID number is
1702.
c From the Use Input ES PID Numbers drop-down list, choose Yes to use the
input ES PID number. Otherwise, choose No (default) to use the first ES PID
number and the ES PID offset number assigned below.
i In the First Channel First ES PID Number field, enter the first ES PID
number. The default is 101.

186 OL-31980-01
Configuring Transport Stream Information

ii In the First ES PID Numbers Offset field, enter the offset of the first ES
PID of subsequent channel numbers. For example, if the First ES PID
Number is set to 101 and the ES PID Numbers Offset is set to 100, then
the first ES PID number is 101, and the second ES PID number is 201.
d From the Use Input PMT ES Stream Order drop-down list, choose Yes to
assign the ES PID according to the incoming PMT order. Otherwise, choose
No to use the reserved PIDs defined below.
i In the PCR, VID, AUD, SUBT, VBI, DPI, MPE, TTX, DATA, LSD, CDT,
ETV fields, enter the number of PIDs for the specified streams (PCR, VID,
AUD, SUBT, VBI, DPI, MPE, TTX, DATA, LSD, CDT, ETV) in one
channel.
e Click OK.
4 From the Enable Auto Map For Auxiliary PEs drop-down list, choose Yes for
the DPM to set the output actions for all the Auxiliary PEs to MAP when the
Output Mode is set to Transcode. If the Enable Fixed Table Output is set to Yes,
the output configuration for the auxiliary PEs is determined by the fixed output
table options when you resynchronize the output channels and PIDs to match
the input programs.
Note: The DPM resolves any output conflicts automatically, even if the Enable
Auto Fix for Collision is set to No.
5 Click Apply.

Viewing the ASI Output Status


The ASI Output Status area displays the current Output Rate (0 to 213 Mbps) and
the available bit bandwidth (Free Bandwidth), in Mbps.

OL-31980 -01 187


Chapter 5 Web GUI Setup and Monitoring

Configuring the DPM ASI Details


Note: The following procedure defines all the available fields. For a typical setup of
the DPM, see Typical set up for Digital Program Mapping (DPM) (on page 210).
Note: After you make any changes, a successfully updated (session open) message
appears. The changes are displayed, but not saved. You must click Apply to save
and apply the changes.
1 From the user interface of the D9859, choose Transport Stream > Digital
Program Mapping. The ASI Digital Program Mapping page is displayed.

2 For each DPM Program Entry, it displays the input channel number (Chl #) and
channel Name.
There are eight channels (PE1 to PE8), with eight a uxiliary channels (PE1A to
PE8A). The auxiliary channels automatically tune to the corresponding PE
channels. If the main PE is not transcoding, the auxiliary PE is dropped.
Note: Any changes made to the ASI DPM values will automatically change the
Mode Status to Edited by User in the ASI Outputs page.
3 In the table, select the program entry you want to edit the Action setting.
In the Action drop-down list, choose the DPM program action for the PE (Pass,
Map, Drop, or XCode). The auxiliary programs (P1A to P8A) cannot be set to
XCode.
Click Save.

188 OL-31980-01
Configuring Transport Stream Information

If you want to configure an auxiliary PE, we highly recommend that you


perform the following:
- From the Enable Auto Map For Auxiliary PEs drop-down list, choose Yes in
the ASI Outputs page.
- Set PxA to Map.
- Click Resynchronize All to ensure that the inputs and outputs are the same.
4 Select the program entry you want to edit.
5 Click Edit. The DPM PE PID MAP window opens.

6 In the Output Channel # field, enter the output channel number you want to
map to the input channel (Input Channel #). This value is only used if the PE
Action is set to Map. You can enter a range from 1 to 65535.
7 In the Output PMT PID field, enter the output PMT PID number you want to
map to the Input PMT PID.
8 In the PE PID MAP area, you can select an existing PID mapping entry you want
to modify or click Add Row to create a new entry.
9 The Input Stream indicates the input service that will be mapped by the current
entry. The Input PID displays the input PID (1 to 8190) that will be mapped by
the current entry. This is only used if the Action is set to Map.
10 From the Action drop-down list, choose the action to perform on the current
PID. The Drop action is always performed, but the Map option is only applied if
the PE Action is Map and the Remapping Mode is Svc ID & PID in the DPM
General Settings area.

OL-31980 -01 189


Chapter 5 Web GUI Setup and Monitoring

Action Description

Drop The service selected by the Category and Instance will be mapped
to the specified PID. This is only applied if the PE action is Map
and the Remapping Mode is Svc ID & PID.
Map The service selected by the Category and Instance will be removed
from the PMT and the output stream.
11 In the Stream Type field, enter a stream type to map within a PE to a specified
PID (0 to 255).
12 From the Category drop-down list, choose the service to configure. If an input
service matches this type and Instance, then the Action will be applied. This
value is only used if the Action is set to Map. The categories are: UNKN, CDT,
LSDT, DATA, TTX, MPE, DPI, VBI, SUBT, AUD, VID, PCR or INVL.
13 In the Instance field, enter the instance of the service specified by Category to
configure (1 to 64). If an input service matches this type and instance, then the
Action will be applied.
14 If Action is set to Map, enter the Output PID number (0 to 8192).
15 Click Save.
16 Click OK.
To remove a PID mapping, select the entry you want to remove and click Delete.

Synchronizing the Inputs


1 In the DPM Program Entry Setup table, each PE output can be synchronized to
its input according to one of the four output modes. Select the program entry
you want to synchronize and then click Resynchronize or click Resynchronize
All to synchronize the inputs to the outputs according to the service assignments
only. The Confirm Resynchronization window is displayed.

2 Check whether you want to synchronize the PE output according to the services
and then the PIDs assigned to each service, services only, PIDs only, or to
synchronize using a template.

Map Mode Description

Resynchronize Program, PMT The transcoder will synchronize the PE output according
PID, ES List & ES PIDs to the services and then the PIDs assigned to each
service.

190 OL-31980-01
Configuring Transport Stream Information

Map Mode Description

Resynchronize ES List The transcoder will synchronize the PE output according


to the available input services only, and ignore the input
to output service PID mapping.

Resynchronize ES PIDs The transcoder will synchronize the PE output according


to the input PIDs only, and ignore the service assignment
categories/names.

Resynchronize Template ES List Allows you to preset the input to output mapping of a PE
& PIDs according to the preset template. This is helpful in pre-
configuring any number of PEs for future use.
3 Click OK.
If a conflict occurs, a message that the conflicts will be fixed automatically and to
preview the changes prior to saving is displayed. Click View Conflicts to view a
detailed list of all the conflicts in the Output Channel and PID Conflicts
window.

 For channel conflicts, the system will only automatically change the
duplicated output channel numbers. If both PE actions are set to Map or
XCode, the output channel number of the higher PE is changed. Otherwise,
the output channel number of the mapped and transcoded PE is changed.
The new channel number selected is the next channel number that does not
appear in the current PAT or belong to any other PEs.
 For PID conflicts, the system will only automatically change the duplicated
output PID numbers. If both PE actions are set to Map or XCode, the output
PID number of the higher PE is changed. Otherwise, the output PID number
of the mapped or transcoded PE is changed. For example, if the PMT PID of
PE1 matches the ES PID of PE2, the ES PID of PE2 is changed. The new PID
number selected is the next number that does not appear in the output of any
PE and it is not in the current transport input.
Click Apply to save the resolved conflict changes.

OL-31980 -01 191


Chapter 5 Web GUI Setup and Monitoring

Configuring DPM General Settings


1 In the DPM General Settings area, you can configure ASI DPM transport stream
settings.
2 From the Remapping Mode drop-down list, choose the DPM mapping mode for
this output. The following table describes each mode:

Map Mode Description

Svc ID The elementary PIDs are not changed. Channels are remapped by
changing their PSI references. When this mode is selected, PE
detailed PID mapping in the PID menu are ignored.

Svc ID & PID Channels and the elementary service PIDs can be mapped in the
DPM PE PID MAP window.
3 From the Duplication Method drop-down list, choose the method on how to
handle duplicate programs. This setting is only used if Remapping Mode is set
to Svc ID & PID. The following table describes the each duplication method:

Duplic Mode Description

PSI Remap Every input PID can be mapped to only one output PID. If PID
mapping conflicts exist, DPM will use the Precedence Rule to decide
which output PID to use. All PMTs using the input PID will be
updated to reference the output PID specified by the winner.

Pkt Copy An input PID can be mapped to multiple output PIDs. The PID will
be duplicated as many times as needed (up to a certain hardware
limitation).
Note: This may increase the output bandwidth of the stream.

Pkt Copy is recommended for most applications.


4 From the Unreferenced Content drop-down list, choose the action to use for
unreferenced content. Unreferenced content is the remainder of the transport
stream that is not filtered by the program entries. Select Drop (default) to drop
all unreferenced content. Select Pass to pass all unreferenced content to the
output unchanged.
5 From the Service ID Output drop-down list, choose whether the transcoder
should always generate PSI tables for the Mapped PE even if the selected input
channel is not available, or for only valid service channels/IDs. The following
table describes each service ID:

Svc ID Description

Valid Ch Only transmits the PSI tables for the mapped program if the
program exists on the input stream.

All Ch Transmits the PSI tables for the mapped program even if the
program does not exist in the input stream.
All Ch is only valid if the PAT, NIT, SDT and PMT are set to
Regenerate.

192 OL-31980-01
Configuring Transport Stream Information

6 If PSI Table Output Option is set to Ctrl by Table, select the regeneration rate for
those PSI tables being regenerated in the SI Regeneration Option drop-down
menu. This parameter is only used if Remapping Control is set to None. The
following table describes each PSI rate:

PSI Rate Description

Auto Matches the generated PSI tables' output rate to the incoming rate.

MPEG Min Transmits the generated PSI tables on the longest intervals that are
allowed by MPEG standard.

SA Std Transmits the generated PSI tables based on PowerVu standard


intervals.
7 From the PSI Table Output Option drop-down list, choose the action to perform
on the PSI tables for the output stream. The table below describes each option.

PSI Options Description

Pass All Transmits the incoming PSI Tables as is; does not modify the
content and rate. The SI Regeneration Option and table settings are
ignored.
Drop All Does not transmit any PSI Tables. The SI Regeneration Option and
table settings are ignored.

Ctl By Table The operator can click Table Options to select the table specific
output mode for each table.
8 If Ctl By Table is selected as the PSI Table Output Option, click Table Options
to configure the DPM table options. The DPM Table Options (ASI) window is
displayed.

OL-31980 -01 193


Chapter 5 Web GUI Setup and Monitoring

Choose the tables which will be passed, dropped, regenerated or passed with
rate control (PwRC) from the ASI Output. For more information on the table
options, see PSI Table Settings (on page 105).
The CDT is different from the other tables listed because the CDT is referred to
within the PMT, rather than outside the PMT. Check the Block CDT Output
check box to override the DPM PID map configuration for CDT PIDs and to
always drop all CDTs. Otherwise, clear the Block CDT Output to permit the
output of CDTs following the configured DPM PID map configuration and all
other DPM constraints.
9 From the PSI Regeneration Option drop-down list, choose whether to
regenerate the PSI tables to the output. Choose Always to regenerate all the
tables or choose As Needed to only regenerate the tables if the content has
changed.
10 Click OK.
11 Click Apply.
12 Click Copy To MOIP to copy all the DPM data from the ASI output to the MPEG
over IP output.

Viewing the ASI Output Transport Status


From the user interface of the D9859, choose Transport Stream > Output Transport
Status under ASI Output. The PID Output Status page is displayed.

194 OL-31980-01
Configuring Transport Stream Information

The Program Entry - Referenced PIDs table displays the specified PE ES PIDs
information on the output.
The Output Channel and PID Conflicts table displays a list of conflicts when the
DPM alarm is active.

Configuring the MPEGoIP Output


1 From the user interface of the D9859, choose Transport Stream > MPEG over IP
Output. The MPEG over IP Output page is displayed.

Note: Any changes made to the MOIP DPM values will automatically change the
Mode Status to Edited by User.
2 From the Rate Control drop-down list, choose the DPM output rate control. The
following table describes the affect each of the settings has on the output bit rate:

OL-31980 -01 195


Chapter 5 Web GUI Setup and Monitoring

Rate Control Description

Auto The output rate follows that set by the uplink. This setting can be
used if the signal source is ASI. If Null Packet Insertion is set to
Yes, the output bit rate is the same as the input rate (including all
the null packets). If Null Packet Insertion is set to No, the output
rate is equal to the payload rate of the transport stream to be
encapsulated, and in most cases, it will be lower than the overall
input rate.

User The output rate is specified by the User Rate field. It is determined
by the user setting regardless of the input source. Null packets are
always inserted when the configured output bit rate is higher than
the payload rate of the transport stream to be encapsulated.
3 In the User Rate field, enter the output user rate, which is only used if Rate
Control is set to User. If the output bit rate is less than the input, the output data
will be partially or completely lost.
Note: Output data will be partially lost if the user-selected bit rate is set to a
value that is less than the actual signal bit rate. This allows you to set the output
bit rate to a value expected by equipment connected to the MPEGoIP output.
You can enter a range from 0 to 206 Mbps.
4 From the Output Mode drop-down list, choose the DPM output mode. With the
exception of No Output and Full DPM Control, choosing a mode will configure
the DPM settings to achieve the specified behavior. In this way, they a ct as DPM
presets. The Mode Status is changed from Unmodified to Edited by User. It is
highly recommended to use either one of these basic modes, or, for advanced
setup, enter the DPM mapping before setting the Output Mode. The following
table describes each mode:

Output Mode Description

No Output No MPEGoIP output will be generated.

Passthrough All PEs will be set to Pass and other DPM settings will also be set.

Service Channels Only service channels will be output.


Only
MAP Passthrough The output will be identical to the input, except that channels
assigned to PEs and PIDs will be mapped using the DPM settings.
If the input is tuned to a valid channel, the PEs are automatically
set to Map. Otherwise, the PEs are automatically set to Drop.
Note: If the PE is mapped, it uses the last saved output MAP
configuration. The output map (for example, output channel PMT)
does not change automatically if the input or channel number is
changed.

196 OL-31980-01
Configuring Transport Stream Information

Output Mode Description

MAP Service This is similar to MAP Passthrough, except that only channels
Channels Only applied to program entries are available on the output. If the input
is tuned to a valid channel, the PEs are automatically set to Map.
Otherwise, the PEs are automatically set to Drop.
Note: If the PE is mapped, it uses the last valid input. The output
map (for example, output channel PMT) does not change
automatically if the input or channel number is changed.

Full DPM Control The output will be generated according to the DPM settings on the
MPEG Digital Program Mapping page. This is a manual control
setting.

Transcoding The output will be generated using the DPM default settings,
except that the DPM Action will be set to XCode and the
Descrambled mode will be set to Descrambled. If the input is
tuned to a valid channel, the PEs are automatically set to XCode.
Otherwise, the PEs are automatically set to Drop.
Note: If the PE is transcoded, it uses the last valid input. The
output map (for example, output channel PMT) does not change
automatically if the input or channel number is changed.

A message appears to confirm that you want to resynchronize the output


changes and PIDs to match the selected input programs. Click Yes.
If a conflict occurs and Enable Auto Map for Collision is set to No, a detailed list
of all the conflicts is displayed in the Output Channel and PID Conflicts table
when you click View Conflicts. You can then resolve the conflicts manually. If a
conflict occurs and Enable Auto Map for Collision is set to Yes, a message that
the conflicts will be fixed automatically and the Output Channel and PID
Conflicts table is empty.

 For channel conflicts, the system will only automatically change the
duplicated output channel numbers. If both PE actions are set to Map or
XCode, the output channel number of the higher PE is changed. Otherwise,
the output channel number of the mapped and transcoded PE is changed.
The new channel number selected is the next channel number that does not
appear in the current PAT or belong to any other PEs.

OL-31980 -01 197


Chapter 5 Web GUI Setup and Monitoring

 For PID conflicts, the system will only automatically change the duplicated
output PID numbers. If both PE actions are set to Map or XCode, the output
PID number of the higher PE is changed. Otherwise, the output PID number
of the mapped or transcoded PE is changed. For example, if the PMT PID of
PE1 matches the ES PID of PE2, the ES PID of PE2 is changed. The new PID
number selected is the next number that does not appear in the output of any
PE and it is not in the current transport input.
Click Apply to save the resolved conflict changes.
5 The Mode Status indicates the current DPM configuration change by a user after
changing the Output Mode. The following is a list of possible statuses:

Mode Status Description

Unmodified No changes were made after setting a new Output Mode.

Edited by User DPM changes were.

Auto Re-Mapped Output map changed automatically to fix the output channel or
PID conflicts at the time of setup.

Changed by Uplink DPM output changes were initiated by an encoder.


6 From the Descrambled drop-down list, choose whether the transcoder should
scramble the output even if it is authorized to receive the channel. The default is
Descrambled.

Descramble Mode Description

Scrambled Scrambles the output channel even if the PE is authorized and can
descramble the channel.

Descrambled Descrambles the output channel, and passes in-the-clear channels.


7 Choose Yes to insert null packets in the output stream from the Null Packet
Insertion drop-down list. Otherwise, Choose No. Null packets are always
inserted if the Rate Control is set to User and the configured output bit rate is
higher than the payload rate of the transport stream to be encapsulated.
Note: We recommend that you set the Null Packet Insertion to Yes, especially if
the Output Mode is set to Transcoding.
8 In the SAP Multicast IP Address field, set the Session Announcement Protocol
destination IP address. This is the IP address where the SAP announcements are
sent, if required.
Note: We do not recommend you to change the default IP address (224.2.127.54).
9 In the SAP Destination UDP Port field, set the SAP destination port number (1
to 65534). This is the UDP port where the SAP announcements are sent, if
required.
Note: We do not recommend you to change the default SAP port 9875.
10 From the Start Ethernet Frame on PCR drop-down list, choose whether to
always transmit a new Ethernet Packet when a new Program Clock Reference
(PCR) arrives (Yes or No).

198 OL-31980-01
Configuring Transport Stream Information

11 From the Port Selection drop-down list, choose the output mode (None, Control
Port, or Data Port). Choose Control Port to always output data on the
Management port. Choose Data Port to always output data on the Data port.
Choose None to disable the MPEGoIP interface.
12 The IP Version field displays the IP protocol. Only IPv4 is currently supported.
13 Click Apply.

Setting Up the MPEG over IP Auto Synchronization Options


The MoIP Auto Sync area allows you to configure the DPM without editing each
output channel and PID separately.
1 In the MPEG over IP Output page (Transport Stream > MPEG over IP Output),
refer to the MoIP Auto Sync area.
2 From the Enable Auto Fix for Collision drop-down list, choose Yes for the DPM
to resolve channel and PID collisions automatically on the transport outputs.
New values are assigned to the parameters that caused the conflict. The new
assigned values are not used by any incoming transport or other PE outputs. If a
collision is detected, you can review the new changes and click Apply to accept
the new changes.
Choose No and a detailed list of all the conflicts is displayed in the Output
Channel and PID Conflicts table (click View Conflicts) when a conflict occurs.
You can then resolve the conflicts manually.
3 From the Enable Fixed Output drop-down list, choose Yes for the DPM to assign
new values for all the output channels and PIDs according to the Fixed Output
Options table when you Resynchronize All. Click Fixed Output Options to
configure the MoIP Fixed Output Options:

OL-31980 -01 199


Chapter 5 Web GUI Setup and Monitoring

a From the Use Input Channel Numbers drop-down list, choose Yes to use the
input channel numbers. Otherwise, set to No (default) to use the first channel
and channel offset assigned below.
i In the First Channel Number field, set the first PE channel number to
use. By default, the channel is set to 1.
ii In the Channel Numbers Offset field, set the subsequent PE channel
numbers. For example, if the First Channel Number is set to 100 and the
Channel Numbers Offset is set to 10, then the first channel number is 100,
and the second channel number is 110.
b From the Use Input PMT PID Numbers drop-down list, choose Yes to use
the input PMT PID number. Otherwise, choose No (default) to use the first
PE PID number and PID offset number assigned below.
i In the First Channel First ES PID Number field, set the first PE PMT PID
number. The default is 1701.
ii In the PMT PID Numbers Offset field, set the offset of the subsequent PE
PMT PID numbers. For example, if the First Channel First ES PID
Number is set to 1701 and the PMT PID Numbers Offset is set to 1, then
the first PMT PID number is 1701, and the second PMT PID number is
1702.
c From the Use Input ES PID Numbers drop-down list, choose Yes to use the
input ES PID number. Otherwise, set to No (default) to use the first ES PID
number and the ES PID offset number assigned below.
i In the First Channel First ES PID Number field, set the first ES PID
number. The default is 101.
ii In the First ES PID Numbers Offset field, set the offset of the subsequent
ES PID numbers. For example, if the First ES PID Number is set to 101
and the ES PID Numbers Offset is set to 100, then the first ES PID number
is 101, and the second ES PID number is 201.
d From the Use Input PMT ES Stream Order drop-down list, choose Yes to
assign the ES PID according to the incoming PMT order. Otherwise, set to No
to use the reserved PIDs defined below.
i In the PCR, VID, AUD, SUBT, VBI, DPI, MPE, TTX, DATA, LSD, CDT,
ETV fields, enter the number of PIDs for the specified streams (PCR, VID,
AUD, SUBT, VBI, DPI, MPE, TTX, DATA, LSD, CDT, ETV) in one
channel.
e Click OK.
4 From the Enable Auto Map For Auxiliary PEs drop-down list, choose Yes for
the DPM to set the output actions for all the auxiliary PEs to MAP when the
Output Mode is set to Transcode. If the Enable Fixed Table Output is set to Yes,
the output configuration for the auxiliary PEs is determined by the fixed output
table options when you resynchronize the output channels and PIDs to match
the input programs.

200 OL-31980-01
Configuring Transport Stream Information

Note: The DPM resolves any output conflicts automatically, even if the Enable
Auto Fix for Collision is set to No.
5 Click Apply.

Setting the Maximum and Minimum Transport Packets


The maximum and minimum transport packets are set in the Limits area of the
MPEG over IP Output page.
1 In the Maximum Transport Packets/Ethernet Frame field, enter the maximum
number of transport packets per IP packet (1 to 7).
2 In the Minimum number Packets/Second field, enter the minimum number of
transport packets per IP packet. You can enter 0 or 2 to 1000.

Configuring MPEG over IP Streams


1 In the MPEG over IP Output page (Transport Stream > MPEG over IP Output),
click Stream. The MPEG over IP Output Stream page is displayed.

The following table describes the stream information:

OL-31980 -01 201


Chapter 5 Web GUI Setup and Monitoring

Stream Details Description

Stream Type of stream (MPTS).

Bitrate (Mbps) This is the bit rate of the stream, in Mbps.

Encapsulation Selects the transport protocol to use for the output stream (UDP or
RTP).

Destination IP Enter the unicast (valid host IP only) or multicast destination IP


address.
Destination UDP This selects the destination port number (1 to 65534).
Port
Note: If you selected RTP for Encapsulation, you must select an
even destination port number.
2 To modify the stream information, select the stream and click Edit.
3 Make the necessary changes and click Save.
4 To configure MPTS advanced settings, select the stream and click Advanced.

The following table describes the MPTS advanced settings:

Advanced Settings Description

Traffic Class Sets the quality of service (0 to 255).

Time to Live (Max #hops) This sets the hop limit of the packet's lifespan (0 to 255).

Source UDP Port This sets the source UDP port number (0 to 65535).
Note: Set the Source UDP Port to 0 to use the default UDP
port (49162).
Announce Type Select RFC 2327 to send the Session Announcement Protocol
(SAP) messages according to the RFC 2327 standard.
Otherwise, select None to not send SAP messages.

Announce Title Source Select User String to use the SAP string as the channel name,
defined in the Announce User's Title below. Otherwise, select
SDT channel to use the SDT string as the channel name.

Announce User's Title If User String is selected as the Announce Title Source, enter
the SAP identifier (ID)/string, up to 31 characters.
5 Click OK.

202 OL-31980-01
Configuring Transport Stream Information

Viewing Stream Details


To view the stream details, click Stream Details in the MPEG over IP Output Main
or Stream page. The following Stream Status table is displayed.

The Stream Status table displays the status of the streams for the control and data
ports.

Viewing the MPEG over IP Output Status


The MOIP Output Status area (MPEG over IP Output Main and Stream pages)
displays the current output bit rates for the control port and data port (0 to 206
Mbps), the configured user rate, MPEG over IP TS overflow status, and whether
there are critical MPEG over IP engine errors.

Configuring the DPM MPEGoIP Output Details


Note: The following procedure defines all the available fields. For a typical setup of
the DPM, see Typical set up for Digital Program Mapping (DPM) (on page 210).
Note: After you make any changes, a successfully updated (session open) message
appears. The changes are displayed, but not saved. You must click Apply to save
and apply the changes.

OL-31980 -01 203


Chapter 5 Web GUI Setup and Monitoring

1 From the user interface of the D9859, choose Transport Stream > Digital
Program Mapping under MPEG over IP Output. The MPEGoIP Digital Program
Mapping page is displayed.

2 For each DPM Program Entry, it displays the input channel number (Chl #) and
channel Name.
There are eight channels (PE1 to PE8), with eight auxiliary channels (PE1A to
PE8A). The auxiliary channels automatically tune to the corresponding PE
channels. If the PE is not transcoded, the auxiliary PE is dropped.
Note: Any changes made to the MOIP DPM values will automatically changes
the Mode Status to Edited by User in the MPEG over IP Output page.
3 Click the radio button of the program entry you want to edit.
If you want to configure an auxiliary PE, it is highly recommended that you
perform the following:
- From the Enable Auto Map For Auxiliary PEs drop-down list, choose Yes in
the ASI Outputs page.
- Set PxA to Map.
- Click Resynchronize All to ensure that the inputs and outputs are the same.
4 From the Action drop-down list, choose the DPM program action for the PE
(Pass, Map, or Drop). The default is Pass.

204 OL-31980-01
Configuring Transport Stream Information

5 Click Edit. The DPM PE PID MAP window opens.

6 In the Output Channel Number field, enter the output channel number you
want to map to the input channel (Input Channel #). This value is only used if
the PE Action was set to Map. You can enter a range from 1 to 65535.
7 In the Output PMT PID field, enter the output PMT PID number you want to
map to the Input PMT PID.
8 In the PE PID MAP area, you can select an existing PID mapping entry you want
to modify or click Add Row to create a new entry.
9 The Input Stream indicates the input program stream category/service type. The
Input PID displays the input program PID (1 to 8190). It is only used if the PID
Action is set to Map.
10 From the Action drop-down list, choose the DPM action for the PID associated
with the PE.

Action Description

Drop Removes the service and its associated PMT reference from the
transport output.

Map Provides the flexibility to define all the outgoing PID numbers for
a PE, including those not currently on transmission.
11 In the Stream Type field, enter the stream type to map within a PE to a specified
PID (0 to 255).
12 From the Category drop-down list, choose the output program stream category
or service type. This value is only used if the Action is set to Map. The categories
are: UNKN, CDT, LSDT, DATA, TTX, MPE, DPI, VBI, SUBT, AUD, VID, PCR or
INVL.
13 In the Instance and Output PID fields, enter the output stream instance (1 to 64)
and the output program PID (0 to 8192).

OL-31980 -01 205


Chapter 5 Web GUI Setup and Monitoring

14 To remove a PID mapping, click the radio button of the entry you want to
remove and click Delete.
15 Click OK.
16 In the DPM Program Entry Setup area, each PE output can be synchronized to
its input according to one of the four output modes. Click the radio button of the
program entry you want to synchronize and then click Resynchronize or click
Resynchronize All to synchronize all the listed PE outputs to its inputs. The
Confirm Resynchronization window is displayed.

17 Select whether you want to synchronize services and PIDs, services only, PIDs
only, or to synchronize using a template.

Map Mode Description

Resynchronize Program, PMT The transcoder will synchronize the PE output according
PID, ES List & ES PIDs to the services and then the PIDs assigned to each
service.

Resynchronize ES List The transcoderwill synchronize the PE output according


to the available input services only, and ignore the input
to output service PID mapping.

Resynchronize ES PIDs The transcoder will synchronize the PE output according


to the input PIDs only, and ignore the service assignment
categories/names.

Resynchronize Template ES List Allows you to preset the input to output mapping of a PE
& PIDs according to the preset template. This is helpful in pre-
configuring any number of PEs for future use.
18 Click OK.

206 OL-31980-01
Configuring Transport Stream Information

If a conflict occurs, a message that the conflicts will be fixed automatically and to
preview the changes prior to saving is displayed. Click View Conflicts to view a
detailed list of all the conflicts in the Output Channel and PID Conflicts
window.

 For channel conflicts, the system will only automatically change the
duplicated output channel numbers. If both PE actions are set to Map or
XCode, the output channel number of the higher PE is changed. Otherwise,
the output channel number of the mapped and transcoded PE is changed.
The new channel number selected is the next channel number that does not
appear in the current PAT or belong to any other PEs.
 For PID conflicts, the system will only automatically change the duplicated
output PID numbers. If both PE actions are set to Map or XCode, the output
PID number of the higher PE is changed. Otherwise, the output PID number
of the mapped or transcoded PE is changed. For example, if the PMT PID of
PE1 matches the ES PID of PE2, the ES PID of PE2 is changed. The new PID
number selected is the next number that does not appear in the output of any
PE and it is not in the current transport input.
Click Apply to save the resolved conflict changes.

Setting the DPM General Settings


1 In the DPM General Settings area, you can configure MPEGoIP DPM transport
stream settings.
2 From the Remapping Mode drop-down list, choose the DPM map mode. The
following table describes each mode:

Map Mode Description

Svc ID The elementary PIDs are not changed. Channels are remapped by
changing their PSI references. When this mode is selected, PE
detailed PID mapping cannot be edited.

Svc ID & PID Channels and the elementary service PIDs can be mapped.

OL-31980 -01 207


Chapter 5 Web GUI Setup and Monitoring

3 From the Duplication Method drop-down list, choose the duplication method of
the DPM program, which modifies the PSI to duplicate a program and its
content. This parameter is only used if Remapping Mode is set to Svc ID & PI D.
The following table describes the each duplication method:

Duplic Mode Description

PSI Remap Every input PID can be mapped to one output PID. If PID
mapping conflicts exist, DPM will use the Precedence Rule to
decide which output PID to use. All PMTs using the input PID
will be updated to reference the output PID specified by the
winner.
Pkt Copy An input PID can be mapped to multiple output PIDs. The PID
will be duplicated as many times as needed (up to a certain
hardware limitation).
Pkt Copy is recommended for most applications.
4 Select the DPM action to use for Unreferenced Content. Unreferenced content is
the remainder of the transport that is not filtered by the program entries. Select
Drop (default) to drop all unreferenced content. Select Pass t o pass all
unreferenced content to the output unchanged.
5 From the Service ID Output drop-down list, choose whether the transcoder
should always generate PSI tables for the Mapped PE even if the selected input
channel is not available, or for only valid service channels/IDs. The following
table describes each service ID:

Svc ID Description

Valid Ch Only transmits the PSI tables for the mapped program if the
program exists on the input stream.
All Ch Transmits the PSI tables for the mapped program even if the
program does not exist in the input stream.
All Ch is only valid if the PAT, NIT, SDT and PMT are set to
Regenerate.
6 From the SI Regeneration Option drop-down list, choose the SI regeneration
option that applies the PowerVu rates (consistent with the uplink). This
parameter is only used if Remapping Control is set to None. The following table
describes each PSI rate:

PSI Rate Description

Auto Matches the generated PSI tables' output rate as the incoming rate.

MPEG Min Transmits the generated PSI tables on the longest intervals that are
allowed by MPEG standard.

SA Std Transmits the generated PSI tables based on PowerVu standard


intervals.

208 OL-31980-01
Configuring Transport Stream Information

7 From the PSI Table Output Option drop-down list, choose which PSI tables to
include in the program/output stream. The following table describes each
option:

PSI Options Description

Pass All Transmits the incoming PSI Tables as is; does not modify the
content and rate.

Drop All Does not transmit any PSI Tables.

Ctl By Table The operator can click Table Options to select the output mode
for each table. The default table selections will be all pass, and
only with CDT dropped.
8 From the PSI Regeneration Option drop-down list, choose whether to
regenerate the PSI tables. You can select Always or As Needed (only if t he
content has changed).
9 If Ctl By Table was selected as the PSI Table Output Option, click Table
Options to configure the DPM table options. The DPM Table Options (MOIP)
window is displayed.

10 Choose the tables which will be passed, dropped, regenerated or passed with
rate control (PwRC) from the ASI Output. For more information on the table
options, see PSI Table Settings (on page 105).
The CDT is different from the other tables listed because the CDT is referred to
within the PMT, rather than outside the PMT. Check the Block CDT Output
check box to override the DPM PID map configuration for CDT PIDs and to
always drop all CDTs. Otherwise, uncheck the Block CDT Output to permit the
output of CDTs following the configured DPM PID map configuration and all
other DPM constraints.

OL-31980 -01 209


Chapter 5 Web GUI Setup and Monitoring

11 Click OK.
12 Click Apply.
13 Click Copy To ASI to copy all the DPM data from the MPEG over IP output to
the ASI output.

Viewing the MPEG Output Transport Status


From the user interface of the D9859, choose Transport Stream > Output Transport
Status under MPEG over IP Output. The PID Output Status page is displayed.

The Program Entry - Referenced PIDs table displays the specified PE ES PIDs
information on the output.
The Output Channel and PID Conflicts table displays a list of conflicts when the
DPM alarm is active.

Typical set up for Digital Program Mapping (DPM)


1 Verify that you are receiving a valid signal and that you have set up the channels
that you want to pass, drop, or map.
2 From the user interface of the D9859, choose Transport Stream > ASI Output or
MPEG over IP Output.
3 From the Output Mode drop-down list, choose Full DPM Control.

210 OL-31980-01
Configuring Transport Stream Information

4 If necessary, select the Descrambled mode according to whether the program is


to be scrambled or descrambled for downstream viewing or monitoring.
5 Click Apply.
6 Choose Transport Stream > Digital Program Mapping for ASI Output or
MPEG over IP Output. The ASI or MPEGoIP Digital Program Mapping page is
displayed.
7 In the DPM Program Entry Setup, click Resynchronize All and select
Resynchronize Program, PMT PID, ES List & ES PIDs and click OK. This
copies the input services PIDs to the remapped output service PIDs.
8 In the DPM Program Entry Setup table, select the PE containing the channel you
want to configure and click Edit. The DPM PE PID MAP window is displayed.
9 From the Action drop-down list for an input stream, choose Drop or Map.
10 Configure the input to output channel mapping from the Category drop-down
list. Video and PCR can be output on the same PID or different PIDs. If output on
the same PID, they will appear identical to the input.
11 Click Save.
12 Click OK.
13 In the DPM General Settings section, set the following parameters:

Parameter Description

Remapping Mode Svc ID & PID

Duplication Method Pkt Copy

Unreferenced Content Drop

Service ID Output Valid Ch/All Ch

PSI Table Output Option Ctl By Table

PSI Regeneration Option Always/As Needed


14 Click Table Options. The DPM Table Options (ASI) window is displayed.
15 Set the following parameters:

Parameter Description

PAT Regen

CAT Regen

PMT Regen

TSDT Drop
NIT Regen or Drop

NITO Drop
SDT Regen

OL-31980 -01 211


Chapter 5 Web GUI Setup and Monitoring

Parameter Description

SDTO Drop

BAT Drop

EIT Drop
TDT Pass

RST Pass

TOT Pass

DIT Pass

SIT Pass

ECM Drop

EMM Drop

DRT Drop
16 Check the Block CDT Output check box.
17 Click OK.
18 Click Apply.

212 OL-31980-01
Configuring Transport Stream Information

Setting up Default Settings for the Transcoder


1 From the user interface of the D9859, choose Transport Stream > Transcoder
Setup. The Transcoder Setup page is displayed.

Note: Subtitle Burn-In is not supported.


2 From the Action on Loss of Input drop-down list, choose the transcoder action
on loss of input, which is the action that the transcoder takes when there is a loss
of input signal (No Output or Black Output).
3 Click the Transcoder 1 Output to Transcoder 8 Output radio buttons to select
the transcode channel video mode. The selections are Auto, HD Output, and SD
Output.

Setting Description

Auto Leaves the input video format and resolution


unchanged. That is, SD in - SD out, HD in -
HD out.

OL-31980 -01 213


Chapter 5 Web GUI Setup and Monitoring

Setting Description

SD Output Down-converts from HD to SD when


receiving an HD input signal. SD horizontal
resolution will follow the HRes parameter
set in the SD Settings column of the
Transcoder Settings window (click
Transcoder Config).

HD Output Up-converts from SD to HD1080i when


receiving an SD input signal. HD horizontal
resolution will follow the HRes parameter
set in the HD Settings column of the
Transcoder Settings window (click
Transcoder Config).

4 The Remaining Transcoders field displays the remaining HD or SD licenses


available to transcode on the unit. The number of resources available is updated
automatically when you choose HD Output or SD Output as the Transcoder
Output.

Configuring Transcoder Settings


Select the channel channel you want to configure settings and click Transcoder
Config. The Transcoder Settings window is displayed.

If the selected channel is set to HD Output, proceed as follows:


1 In the HD Settings column, choose the transcode channel HD horizontal output
video resolution from the HRes drop-down list. You can select Full or 3/4. The
following table displays the settings:

214 OL-31980-01
Configuring Transport Stream Information

Setting Description

Input Resolution Output Resolution

Full 1080i 1920

3/4 1080i 1440

Full 720p 1280

3/4 720p 960


2 From the Bitrate Mode drop-down list, choose the transcode channel output
bitrate mode. You can select VBR or CBR.
3 In the Rate field, enter the HD rate that sets the transcode channel output bit rate
when HD MPEG-4/AVC to HD MPEG-2 transcoding is selected. The range is
from 8 to 25 Mb/s in 400 b/s increments.
4 From the GOP Control drop-down list, choose the Transcode Group of Pictures
(GOP) format. The options are User Gop (MN) or I Frame Sync.
5 From the User GOP drop-down list, choose the transcode manual GOP format
value. The transcoder attempts to reuse information from the encoded bit stream
to improve the video quality of the transcoded stream. Amongst others, if the
incoming GOP structure is similar to that of an MPEG-2, it will reuse the frame
allocations from the incoming stream as long as GOP Control is set to I Frame
Sync. If the downstream transcoder does not support altering GOP structures, set
the GOP Control setting to User GOP (MN). This will also require the setting of
the GOP structure which is given as two numbers, where the first is the length of
the GOP and the second is the number of B-pictures per sub-GOP. The
supported GOP structures are 1.0, 12.2, 15.2, 24.2 and 30.2.
6 From the 3:2 Pulldown drop-down list, choose Enabled or Disabled to enable or
disable the 3:2 Pulldown.
7 Click OK.

If the select channel is set to SD Output, proceed as follows:


1 In the SD Settings area, select the transcode channel SD horizontal output video
resolution from the HRes drop-down list. The parameters are 352, 480, 528, 544,
704 or 720.
2 From the Bitrate Mode drop-down list, choose the transcode channel output
bitrate mode. You can select VBR or CBR.
3 In the Rate (Mbps) field, enter the transcode channel output bit rate when HD to
SD transcoding is selected for the output channel. You can enter a range from 2
to 15 Mb/s, in 400 b/s increments.
4 From the GOP Control drop-down list, choose the Transcode Group of Pictures
(GOP) format. The options are User Gop (MN) or I Frame Sync.

OL-31980 -01 215


Chapter 5 Web GUI Setup and Monitoring

5 From the User GOP drop-down list, choose the transcode manual GOP format
value. The transcoder attempts to reuse information from the encoded bit stream
to improve the video quality of the transcoded stream. Amongst others, if the
incoming GOP structure is similar to that of an MPEG-2, it will reuse the frame
allocations from the incoming stream as long as GOP Control is set to I Frame
Sync. If the downstream transcoder does not support altering GOP structures, set
the GOP Control setting to User GOP (MN). This will also require the setting of
the GOP structure which is given as two numbers, where the first is the length of
the GOP and the second is the number of B-pictures per sub-GOP. The
supported GOP structures are 1.0, 12.2, 15.2, 2 4.2 and 30.2.
6 From the 3:2 Pulldown drop-down list, choose Enabled or Disabled to enable or
disable the 3:2 Pulldown.
7 From the Output Aspect Ratio drop-down list, choose the aspect ratio for the SD
transcode output channel. The options are 4:3 and 16:9 (wide aspect ratio). The
default is 4:3. Set it to the corresponding value.
8 From the Aspect Ratio Conversion drop-down list, choose the SD transcode
channel aspect ratio conversion. This is the conversion that the transcoder will
perform on the output signal for the picture to be displayed correctly (i.e., to
correspond to the aspect ratio of your TV) on your TV, based on your selection.
The options are: Auto, None, 16:9 L/B (letter box), 4:3 CCO, 14:9, 4:3 P/B (pillar
box), 16:9 SCALE, or Auto AFD (Auto setting using Active Format Descriptor).
The default is set to Auto.
9 From the Closed Caption Packet 1 and Closed Caption Packet 2 drop-down
lists, choose the order to output the closed caption packets on the transcoded SD
output. The options are None, SCTE-20, or CEA 708.
10 Click OK.

Applying Inband Settings


Note: The Apply Inband Settings is not supported in the current release. You can
apply the inband settings using the front panel. For more information, see Inband
(on page 112).

216 OL-31980-01
Configuring Transport Stream Information

1 Click Apply Inband Setting to apply the uplink parameters for transcoding,
such as bit rate, GOP and resolution, to the local transcoder settings for the
selected program entry. This is only supported with an uplink that uses uplink
transcoding controls for the user address of the selected program entry. The
Apply Inband Settings window is displayed.

2 Check a transcoder/program entry check box.


3 Click OK.

OL-31980 -01 217


Chapter 5 Web GUI Setup and Monitoring

Configuring System Settings


Viewing the System Identification
1 From the user interface of the D9859, choose System Settings > System. The
Identification page is displayed.

2 The System Identification page displays the parameters associated with the
D9859 system, such as serial number, model number, and user addresses.
3 You may optionally change the Hostname (device name) and click Apply.

218 OL-31980-01
Configuring System Settings

Viewing Hardware Features and Base License Information


From the user interface of the D9859, choose System Settings > Identification >
Features/Licenses. The Features/Licenses page is displayed.

The Hardware Features area displays the hardware options installed in the current
D9859 Advanced Receiver Transcoder. For example, it indicates whether the
transcoder is equipped with an SDI output and the number of transcoding paths.
The Feature License Summary area displays the total number of PEs for HD and/or
SD transcode. The HD Transcode License Count displays the number of program
entries that can transcode both SD and HD. The SD Transcode License Count
displays the number of program entries that can transcode SD only.
For example, a fully licensed D9859 Advanced Receiver Transcoder (with additional
6 SD and 7 HD upgrades) is displayed as follows:
HD Transcode License Count: 8

SD Transcode License Count: 0


Note: If an asterisk (*) appears next to the license count, it indicates that the unit is
currently processing a license file.

OL-31980 -01 219


Chapter 5 Web GUI Setup and Monitoring

Setting up IP Information
1 From the user interface of the D9859, choose System Settings > IP Settings. The
IP Settings page is displayed.

Note: The D9859 transcoder is a single data port unit. The Redundancy Control
and Redundancy Status sections are not supported.
2 In the IP Settings table, you can set the parameters for communicating with other
equipment via the Ethernet Data and Management ports for IP applications and
upgrading application software.
3 Click the control or data radio button to edit the control or data settings and set
the IPv4 Destination IP Address for the interface. The address is 12 digits in
length (###.###.###.###). The Statmux port is not supported.
4 Set the number of CIDR (Classless Inter-Domain Routing) bits in the network
Mask (8 to 30).

220 OL-31980-01
Configuring System Settings

5 In the Gateway Address field, enter the gateway IP address on the Network,
used to expose the transcoder to a WAN. The IP Address, IP Mask, and Gateway
Address should be changed together, that is, as a group. The following table
shows the most commonly used Subnet mask values to enter for a chosen IP
address mask, which will depend on the size of your network.

Mask Subnet Mask


8 255.0.0.0
16 255.255.0.0

24 255.255.255.0
6 From the PHY Mode drop-down list, choose the speed and duplex type of the
interface. Choose Auto for PHY to negotiate speed and duplex with other
devices on the network, or select 10 HD (half-duplex), 10 FD (full-duplex), 100
HD, 100 FD, or 1000 FD to lock into a fixed mode. Otherwise, choose N/A. The
default is Auto.
7 Click Save.

Protocol Control Settings


The Protocol Control area allows you to control remote access protocols to the IRD
(Telnet, SSH, HTTP, HTTPS (via HTTP secure setting), and SNMP).
1 From the Telnet, SSH, HTTP, and SNMP drop-down list, choose Enable
(default) to allow Telnet, Secure Shell, HTTP, and/or SNMP connections.
Otherwise, choose Disable.
The following lists the associated port numbers for each protocol:

Protocol Port Number

Telnet TCP port #23

SSH TCP port #22

HTTP TCP port #80

HTTPS (via HTTP secure TCP port #443


setting)

SNMP UDP port #161


For information on accessing TCP/IP services, see Accessing TCP and UDP
Services (on page 74).
The HTTP has an additional Secure setting for an encrypted access to the
webserver (HTTPS).
a From the HTTP drop-down list, choose Secure. A confirmation message that
you will be logged out automatically is displayed.

OL-31980 -01 221


Chapter 5 Web GUI Setup and Monitoring

b Click OK to confirm. It will reconfigure the device and the next time you log
in, you will be accessing the encrypted version (HTTPS). A untrusted
connection warning message is displayed (first time only). The following is
an example:

c Add the current address as and exception and you can access the D9859 web
GUI.
Note: The HTTPS is displayed in the IP address to denote that it is a secure
access. The following is an example:

2 In the Idle Timeout (seconds) field, enter the number of seconds before the
session for all the enabled protocols will timeout due to inactivity.
3 Click Apply.

System Logs
From the Syslog drop-down list, choose the logging protocol to use (Syslog TCP or
Syslog UDP). The Legacy option is used by Cisco customer support only. Choose
Disable to disable system logging.
If Syslog TCP or Syslog UDP is selected, set the IP address of the server in the
Syslog Server IP Address field and the server UDP or TCP port number in the
Syslog Server Port field. The address is 12 digits in length (###.###.###.###), in
the range from 0 to 255.

222 OL-31980-01
Configuring System Settings

We highly recommended that you use the following syslog servers:

 Syslog-ng - Balabit for Linux (http://www.balabit.com/network-


security/syslog-ng/opensource- logging-system)

 Syslog Watcher - SnmpSoft for Windows


(http://www.snmpsoft.com/downloads.html)

The following is an example of a syslog:

Viewing the Link Status


The Link Status table displays the port information, such as the status, speed, duplex
and crossover. Port 1 is the management port and port 2 is the data port.

OL-31980 -01 223


Chapter 5 Web GUI Setup and Monitoring

Setting up IP Routing Information


1 From the user interface of the D9859, choose System Settings > IP Settings > IP
Unicast Routing. The IP Unicast Routing page is displayed.

2 From the RIP drop-down list, choose Enable to enable the Routing Information
Protocol (RIP). Otherwise, choose Disable. This is a standard protocol for
automatic unicast route discovery. If enabled, the routing information is
displayed in the Installed Unicast Routes table.
3 Click Apply.
4 In the Static Unicast Routing table, you can set the static unicast routing
information used to by MPEGoIP and MPE outputs to send data packets. It can
also be used to find hosts behind a router (for example, an FTP server, a syslog
server, or an NTP server).
To add a unicast route:
a Click Add Row.
b In the Destination IP Address field, enter the IP address that sets the
destination for the unicast route. You can enter up to 12 characters (for
example, 155.128.100.200).
c In the Mask field, enter the number of CIDR (Classless Inter-Domain
Routing) bits in the network mask (8 to 30).

224 OL-31980-01
Configuring System Settings

d In the Gateway Address field, enter the gateway IP address on the Network,
used to expose the transcoder to a WAN. The following table shows the most
commonly used Subnet mask values to enter for a chosen IP address mask,
which will depend on the size of your network.

Mask Subnet Mask

8 255.0.0.0

16 255.255.0.0

24 255.255.255.0
e Check the Port 1 and/or Port 2 check box. The management port is port 1
and the data port is port 2.
f Click Save. The routing information is displayed in the Installed Unicast
Routes table. If the configured routing information has an inactive port, then
the routing information is not displayed in the Installed Unicast Routes
table.

OL-31980 -01 225


Chapter 5 Web GUI Setup and Monitoring

Configuring the MPE Settings


1 From the user interface of the D9859, choose System Settings > IP Settings >
MPE. The MPE page is displayed.

2 From the MPE Data Filter Mode drop-down list, choose whether the MPE data
is forwarded to the network (Forward None, Forward All, or Forward Filtered).
Choose Forward None to not forward MPE data to the network. Choose
Forward All to forward all the MPE data to the network. Choose Forward
Filtered to only forward the MPE data from the defined Static Multicast Filtering
table below to the network. For more information on configuring the Static
Multicast Filtering table, see To Add a Static Multicast Filtering (on page 227).
Note: The transcoder supports up to a maximum of 10 Mbps throughput when
forwarding 1500 byte packets.
3 Click Apply.

226 OL-31980-01
Configuring System Settings

To Add a Static Multicast Filtering


1 Click Add Row in the Static Multicast Filtering table.

2 Type the IP Address that sets the destination for multicast MPE data, in the
range from 224.0.0.0 to 239.255.255.255.
Note: If MPE Data Filter Mode is set to Forward All or Forward Filtered, all the
unicast MPE data will be forwarded, regardless of the Static Multicast Filtering
table.
3 Click Save.

To edit/delete an existing multicast filter address, select the address entry by


clicking on the radio button. Click Edit and make the necessary changes, or click
Delete to remove the address from the Static Multicast Filtering list.

OL-31980 -01 227


Chapter 5 Web GUI Setup and Monitoring

Setting up SNMP Information and Trap Destinations


1 From the user interface of the D9859, choose System Settings > IP Settings >
SNMP. The SNMP page is displayed.

2 In the Read Community String and the Write Community String fields, enter
public (default) or custom string. Set the password to read/write data from a
device and to display diagnostic traps/alarms. This is used when
communicating with a device within an SNMP environment. To set a custom
community string, enter an alphanumeric character string up to 31 alphanumeric
characters in length identifying the password for the device.
Note: The community string is case-sensitive.
3 In the System Name, System Location, and System Contact fields, enter the
information of the D9859 transcoder. The system information is sent to the MIB
browser, if applicable. The MIB Browser is a third party software used to manage
SNMP requests. For more information, contact Cisco Services.
4 Click Apply.

To Add a Trap Destination


1 Click Add Row in the Trap Destination Configuration area.

2 In the Trap Destination IP Address field, enter the IP address that sets the
destination for SNMP trap messages for system events (fault messages). You can
enter up to 12 characters.

228 OL-31980-01
Configuring System Settings

3 In the Community String field, enter the community string for the trap
destination (IP Address entered above).
Enter public or custom string. The default is public. You can enter a string up to
35 characters.
4 To edit/delete an existing trap destination, select the trap destination entry by
clicking on the radio button. Click Edit and make the necessary changes, or click
Delete to remove the address from the Trap Destination Configuration list.
5 Click Save.

OL-31980 -01 229


Chapter 5 Web GUI Setup and Monitoring

Configuring Time/Clock Settings


1 From the user interface of the D9859, choose System Settings > Time/Clock. The
Time/Clock page is displayed.

2 From the Date Format drop-down list, choose the date format of the transcoder.
The following formats are supported: YYYY_MM_DD, DD_MM_YYYY,
MM_DD_YYYY.
3 From the Time Format drop-down list, choose the time format of the transcoder.
Current time information is normally broadcast as part of the transmitted digital
signal. It is broadcast as GMT (Greenwich Mean Time) with date information in
Modified Julian Date format. The following formats are supported: 24Hr, 24 Hr
SuspendZero (the leading zero is dropped from the time), 12Hr, 12Hr
SuspendZero (the leading zero is dropped from the time).
4 From the GMT Offset drop-down list, choose the GMT offset. The local time is
displayed using a time zone (GMT offset). If your local time is not GMT, you
must set this time setting in the range from -12.0 to +12.0 hours in 0.5 hour
increments.
5 The Current TDT Time/Date displays the current TDT (Time and Date Table)
date and time received from the DVB stream. This is displayed as local time.
6 Check the Enable NTP Time Service check box to periodically request NTP
(Network Time Protocol) timestamps from the NTP server (NTP server address
set below) and to synchronize its system (i.e., non-DVB related) time with the
NTP server. This is displayed as local time.
7 In the NTP Server Address field, enter the IP address of the NTP server. If the
NTP server address is not set (0.0.0.0), the unit will not attempt to connect to the
server.
8 The Current NTP Time/Date field displays the current time if the unit receives a
valid reply from the NTP server (adjusted to local time zone).
9 Click Apply.

230 OL-31980-01
Configuring System Settings

Viewing the Alarm/Warning Status


From the user interface of the D9859, choose System Settings > Status. The Alarm
Status page is displayed.

The Status page displays all the active event messages for the D9859 system. The
Fault Summary table displays the Type of message (alarm or warning) and the
number of alarms and warnings that have an active status ( Number Active).

The following table shows the Alarm/Warning Status table information:

Status Description

Type Shows whether it is an alarm or a warning message.

Name Name of the alarm or warning. For more information on


alarm messages, refer to D9859 Transcoder Alarm Messages
(on page 260).

Text Content of the message.

Set Since Date and time of the alarm or warning.

Click Clear Alarms/Warnings to clear all the messages in the Alarm/Warning Status
table.

OL-31980 -01 231


Chapter 5 Web GUI Setup and Monitoring

Setting up Alarms and Warnings


To Set Up Alarms
1 From the user interface of the D9859, choose System Settings > Setup. The
Alarm Setup page is displayed.

2 Check the Enable Alarm/Warning Front Panel Reminder check box and the
highest priority alarm flashes on the LCD display for a two-second interval every
10 seconds. The alarm will continue to flash periodically until it is either cleared
or the Enable Alarm/Warning Front Panel Reminder is unchecked.
3 Check the Enable Video Cutoff on Alarm Condition check box to cut off the
video output if any enabled alarm is active on the transcoder. When video is cut
off, there will be no horizontal or vertical synchronization on the output. This is
useful for downstream redundancy switching by detecting a loss of video signal.
4 Click the Trap Configuration link to view and/or modify SNMP trap
destinations. The link will open the SNMP page. For more information, see
Setting up SNMP Information and Trap Destinations (on page 228).
5 The Alarm Setup area displays a list of the alarm/fault messages. For more
information on alarm messages, refer to D9859 Transcoder Alarm Messages (on
page 260).

232 OL-31980-01
Configuring System Settings

6 From the Enable/Disable drop-down list, choose Yes and the alarm message will
be reported. Choose No and the alarm is disabled and the Relay and Trap
settings are ignored.
Note: The Enable/Disable drop-down list must be set to Yes for the Relay and
Trap settings to be functional.
7 If current alarm is enabled, set Trap to Yes and the SNMP trap message will be
sent when the alarm is set or cleared.
Note: No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the alarm is disabled (Enb is set to No).
8 If current alarm is enabled, choose Yes from the Relay drop-down list for the
rear panel alarm relay to be triggered when the alarm is set or cleared.
Note: No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the alarm is disabled (Enb is set to No).
9 Click Apply.

To Set Up Warnings
Proceed as follows to set up the warning parameters:
1 From the Alarm Setup page, click on the Warning Setup link at the bottom left
hand corner of the page. The Warning Setup page is displayed.

2 Check the Enable Alarm/Warning Front Panel Reminder check box and the
warning flashes on the LCD display for a two-second interval every 10 seconds.
The warning will continue to flash periodically until it is either cleared or the
Enable Alarm/Warning Front Panel Reminder is unchecked.
3 The Warning Setup area displays a list of the warning messages. For more
information on warning messages, refer to D9859 Transcoder Alarm Messages
(on page 260).

OL-31980 -01 233


Chapter 5 Web GUI Setup and Monitoring

4 From the Enable/Disable drop-down list, choose Yes and the warning message
will be reported. Choose No and the warning is disabled and the Relay and Trap
settings are ignored.
Note: The Enable/Disable drop-down list must be set to Yes for the Relay and
Trap settings to be functional.
5 If current warning is enabled, choose Yes from the Trap drop-down list and the
SNMP trap message will be sent when the warning is set or cleared.
Note: No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the warning is disabled (Enb is set to No).
6 If current warning is enabled, set Relay to Yes for the rear panel alarm relay to
be triggered when the warning is set or cleared.
Note: No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the warning is disabled (Enb is set to No).
7 Click Apply.

234 OL-31980-01
Configuring System Settings

Viewing Alarm/Warning History


From the user interface of the D9859, choose System Settings > History. The Alarm
History page is displayed.
Note: The Alarm History page is also access by choosing Support > Alarm History.

The Alarm and Warning History page displays all the past system event messages
and their set and cleared dates and times. For more information on the alarm
messages, refer to D9859 Transcoder Alarm Messages (on page 260).
Click Clear Alarms/Warnings History to clear all the messages in the Fault History
table. Click Export to export the alarm history to a .csv file. The File Download
dialog is displayed. Click Save to save the file to your local drive.

OL-31980 -01 235


Chapter 5 Web GUI Setup and Monitoring

Viewing Version Information


From the user interface of the D9859, choose System Settings > Versions. The
Versions page is displayed.

The Current Versions area displays the currently running loaded application
version and the current limit for the Field Programmable Gate Array (FPGA) version
number. In the Version Controls section, in the first drop-down list (SW APP), you
can choose a different application version number to load. In the second drop -down
list (FPGA), you can choose a different FPGA version number to load. The Selected
Version window is displayed. Click Select & Reboot to load the selected application
and reboot the transcoder. Click Erase to remove the selected application version.
You will be prompted to continue or not. Click OK to continue the deletion.

The Main Board - Firmware Versions area displays the following version
information:

Firmware Version Description

Boot5514/Boot7109 Software boot-loader version that initializes and


configures the STi5514/STi7109 device on the TMB
(main) board. This is the master controller for the
D9859 transcoder.

236 OL-31980-01
Configuring System Settings

CPLD-5514/CPLD-7109 Software Configurable Programmable Logic Device


version attached to the STi5514/STi7109.

FP-PIC Front panel controller version for the D9859


transcoder.

The HW Board Versions table displays the revisions, option bits, and serial numbers
of the main board (TMB) and the transcoder board (TXB).

In the Download FPGA/APP area, click Choose File to select the new version of
FPGA or the D9859 Advanced Receiver Transcoder’s software application. The Open
dialog opens. Select the upgrade file and click Open. Click Download to download
the selected upgrade file. File formats that can be downloaded include application
CDTs and FPGA CDTs.
Note: For application downloads, once the download is complete, the D9859
transcoder will reboot automatically. For FPGA downloads, you must click Reboot
Receiver in the Service Actions page (Support > Service Actions) to manually
reboot the D9859 transcoder and complete the download. This is to facilitate the
typical case in which the user intends to flash the FPGA file (no auto reboot)
followed by an APP download (auto reboot).

OL-31980 -01 237


Chapter 5 Web GUI Setup and Monitoring

The Download Status area displays the current status of the downloads. Click
History and the Download History window is displayed.

Verifying Software and FPGA Integrity Hash Digest


You can generate the hash digest to verify the integrity of the software and FPGA
versions running on the D9859 transcoder. The current and official Cisco D9859
transcoder hash values are published in the D9859 release note. For more
information, see Release Notes for the Cisco D9859 Advanced Receiver Transcoder. If the
generated hash digest values do not match the official list, contact Cisco Services.
To start a communication session with the transcoder, use a utility such as Tera
Term Pro or PuTTY. For more information on starting a Telnet or SSH session, see
Starting a Telnet/SSH Session (on page 30).

238 OL-31980-01
Configuring System Settings

1 At the admin prompt, type hash and press Enter. The hash digest for the D9859
is listed. The following is an example:

2 Verify the hash digest values with the values listed in the appropriate D9859
release note. If the values do not match, contact Cisco Services.

Viewing Transcoder Version Information


From the user interface of the D9859, choose System Settings > Versions Transcode.
The Versions Transcode page is displayed.

OL-31980 -01 239


Chapter 5 Web GUI Setup and Monitoring

The Transcode - Firmware Versions table displays the version numbers applicable to
the Transcoder printed circuit board.

Menu Item Description

Transcoder Board Rev Displays the Printed Circuit Board (PCB) revision of the
transcoder board.

MCL Indicates the hardware initialization version number for the


transcoder devices on the transcoder board.

MDL Displays the software version number that provides


software access to the transcoder devices.

Transcoder Displays the version of the firmware performing the


transcode.

Power Sequencer Indicates the firmware version running on the power-


sequencer, a chip that controls power-up and power-down
of multiple power supplies.

FPGA Indicates the Field Programmable Gate Array (FPGA)


version number.

Transcoder Board SN Indicates the serial number that is uniquely assigned to the
transcoder board.

The HW Board Versions table displays the revisions, option bits, and serial numbers
of the main board (TMB) and the transcoder board (TXB).
The Transcode - Software Versions table lists all the software packages used for the
D9859 transcoder. For more information on the software versions, contact Cisco
customer support.

240 OL-31980-01
Configuring System Settings

Setting up Import/Export File Information


1 From the user interface of the D9859, choose System Settings > Import/Export
File. The Import/Export File page is displayed.

In the Device Settings File Transfer area, you can export and/or import device
settings and transport network information.
2 Click the Export Device Settings & Transport Network Information radio
button and click Export to download device settings and transport network
information as a file to the designated file folder.
3 Click the Export User Device Settings only radio button and click Export to
download user settings as a file to the designated file folder.
4 In the Settings File area, click Browse. The Choose File dialog opens.
Navigate to the appropriate folder and select the file with a .bkp file extension
and click Open. Click Import.

OL-31980 -01 241


Chapter 5 Web GUI Setup and Monitoring

Viewing the Backup/Restore Status


The following table displays the Settings File Backup/Restore/Operation History
information:

Status Description

Last Backup File Name Name of the file to use.

Backup Time Stamp Date and time of the last successful backup file saved.
Last Restored File Name Name of the last file that was restored.

Restore Time Stamp Date and time of the last successful restore.

Operation Status Status of the current backup operation (Inprogress, Pass, or


Fail).

Detailed Operation Status Detailed processing step for tracking backup progress.

Percentage Complete Percentage of backup function completed.

242 OL-31980-01
Configuring System Settings

Setting up Import/Export FTP Information


1 From the user interface of the D9859, choose System Settings > Import/Export
FTP. The Import/Export FTP page is displayed.

2 The Configure Offline FTP Settings File Transfer area has backup and restore
controls.
Note: You must have access to an FTP Server (WinFTP) on a network or a local
PC before you can setup backup/restore controls.
3 In the Settings Filename field, enter the file name of the backup/restore file. You
can enter up to 119 characters.
4 In the FTP Server IP Address field, enter the IP address of the FTP server used to
restore the backup/restore file.
5 In the FTP User Name and FTP Password fields, enter the username and
password to access the FTP server.
Note: The FTP Password is not retained in the transcoder. You must re-enter the
password before initiating the backup or restore operation.
6 In the FTP Port Number field, enter the port number of the FTP server used to
store the backup/restore file. You can enter a port number in the range from 1 to
65535.

OL-31980 -01 243


Chapter 5 Web GUI Setup and Monitoring

7 Click the Export Device Settings & Transport Network Information radio
button to save user settings and tuning information to the backup file. Select
Export User Device Settings Only to save user settings to the backup file.
8 Click Export to save the settings to a backup file. Click Import to retrieve the last
backed up file.

Viewing the Backup/Restore Status


The following table displays the Settings File Backup/Restore/Operation History
information:

Status Description
Last Backup File Name Name of the file to use.

Backup Time Stamp Date and time of the last successful backup file saved.

Last Restored File Name Name of the last file that was restored.

Restore Time Stamp Date and time of the last successful restore.

Operation Status Status of the current backup operation (Inprogress, Pass, or


Fail).

Detailed Operation Status Detailed processing step for tracking backup progress.

Percentage Complete Percentage of backup function completed.

244 OL-31980-01
Configuring System Settings

Managing D9859 Web GUI Accounts


You can define up to 10 usernames/passwords for login use via web GUI session on
the D9859 transcoder.
When a user tries to login, the user is required to provide a username and a
password. The user is granted access only if this username/password pair exists in
the authentication table.
The factory preset "Admin" account has Admin privileges and is allowed to add new
users, delete users, change usernames, and modify its own passwords. Users with
non-Admin privileges (for example, User and Guest) are only allowed to modify
their own passwords.

To Change the User Login Passwords


1 From the user interface of the D9859, choose System Settings > Account
Management. The Account Management page is displayed.

To configure the password complexity for all users:


Note: This feature is only available to a user with Admin privileges only.
2 From the Password Complexity drop-down list, choose the complexity of the
password (No Checking, Minimal Checking, Full Complexity Checking). Any
changes take effect immediately, and do not require the use of the Apply button.
The following describes the rules for each level:

OL-31980 -01 245


Chapter 5 Web GUI Setup and Monitoring

Password Complexity Description

No Checking There are no restrictions on passwords.


Note: A minimum of one character is required.

Minimal Checking A password must comply with the following


requirements:

 It cannot contain username or reversed username.

 It cannot contain any of the following strings: cisco,


sciatl, ocsic, Itaics, atlsci, icslta, or any string
achieved by full or partial capitalization of letters.

 No letter is repeated more than three times in a row.

 Must contain a minimum of four characters.


Full Complexity Checking A password must comply with the following
requirements:

 It cannot contain username or reversed username.

 It cannot contain any of the following strings: cisco,


sciatl, ocsic, Itaics, atlsci, icslta,or any string
achieved by full or partial capitalization of letters.

 No letter is repeated more than three times in a row.

 Must contain a minimum of eight characters.

 Must contain a minimum of three of the following


types of characters: capital letters, small letters,
digits, and special characters.
Note: The complexity level changes will only affect the new user accounts and
password changes. It will not affect existing passwords. Any changes take effect
immediately, and do not require the use of the Apply button.
To change your login password:
Note: You are allowed to only modify your own password.
3 The Change Password for User field displays the password for the current login.
4 In the Enter Current Password field, type the current login password.
5 In the Enter New Password field, type the new login password.
6 In the Re-enter New Password field, type the new login password again to
confirm. Once the password change is successful, the user will be directed to the
login screen to re-enter their username and password.
Note: The Enter New Password and Re-enter New Password should be
identical. Each user, including the admin user, can only modify their own
password.
7 Click Apply.

246 OL-31980-01
Configuring System Settings

To Add a User Account


Note: This feature is available to a user with Admin privileges only.
1 From the Account Management page, click the Manage User Logins link. The
Login Accounts page is displayed.

2 Click Add Account Login to create a new login account.


Note: You can create a maximum of 10 user accounts.
The Add Login Account window is displayed.

3 In the Username field, enter a user ID. The new username should not match any
of the usernames already defined in the Logins Accounts table.

OL-31980 -01 247


Chapter 5 Web GUI Setup and Monitoring

4 In the New Password field, enter a password to assign the user ID. The
password must follow the rules configured in the Set Password Complexity for
All Users parameter. For more information, see To Change the User Login
Passwords (on page 245).
5 Enter the new password again to confirm in the Confirm New Password field.
Note: The New Password and Confirm New Password should be identical.
6 In the Administrator Password field, enter your Administrator password used
to log on to the D9859 web GUI.
7 From the Account Type drop-down list, choose User, Admin, or Guest. The
following table illustrates the different login types:

Account Type Access

Guest View settings only.

User View and edit settings.

Admin View, edit settings, and add/delete user accounts.


8 Click OK.

To Delete a User Account


Note: This feature is available to a user with Admin privileges only.
1 In the Login Accounts table, select the user you want to remove.
Note: if you do not have Admin privileges, NOT ALLOWED is displayed in the
Login Accounts table.
2 Click Delete Account Login. The Delete Login Account window is displayed.

3 In the Administrator Password field, enter your administrator password to


confirm the deletion.
4 Click OK. The selected user account is deleted.

248 OL-31980-01
Configuring System Settings

Configuring Lock Level Settings


1 From the user interface of the D9859, choose System Settings > Lock Level
Settings. The Lock Level Settings page is displayed.

2 Click Change Lock Level and the Change Lock Level window is displayed.

3 From the Lock Level drop-down list, choose the lock level that restricts access
and prevents unauthorized changes to the transcoder settings (0, 1, 2, 3, or 4).
The default setting is 0.
Note: For details on the lock levels, see D9859 Transcoder Lock Levels.
4 In the Enter Password to change the Lock Level field, enter the password to
change the lock level. Depending on the unit, the default password is 1234. For
more information on the default password, contact Cisco Services.
5 Click OK.
If the incorrect lock level or password is entered, an error message appears at the
top of the page.

OL-31980 -01 249


Chapter 5 Web GUI Setup and Monitoring

Changing the Lock Level Password


A unique lock level password (4-digit password) protects the current transcoder
settings against unauthorized changes. When changing the password, record and
keep this number in a secure location. Depending on the unit, the default password
is 1234. For more information on the default password, contact Cisco Services.
Important: Proceed with caution when changing the password as this operation
cannot be undone. If the password is lost or is unavailable, contact Cisco customer
support.
1 In the Lock Level Settings page, click Change Lock Level Password. The Change
Lock Level Password window is displayed.

2 In the Enter Current lock level Password field, enter the current lock level
password.
3 In the Enter New Password field, enter the new password, any number from 0 to
9.
4 In the Re-enter New Password field, re-enter the new password and click OK. A
message appears informing you that the password was changed successfully.
Note: If the password is lost or is unavailable, contact Cisco Services.

250 OL-31980-01
Configuring System Settings

Configuring Front Panel Settings


1 From the user interface of the D9859, choose System Settings > Front Panel. The
Front Panel page is displayed.

2 Check the Enable Automatic Front Panel Keyboard Lock check box to enable
the front panel keypad lock state.
3 In the Keyboard Lock Timeout field, enter the keypad lock timeout period. The
lock timeout period takes effect when the keypad has not been touched (a key
has not been pressed) when on the Main Menu for the set period. Avoid setting
the period to a short duration when the keypad is used often. Enter a value in the
range from 5 to 1800 seconds. The default is 60 seconds.
4 Click Apply.

OL-31980 -01 251


Chapter 5 Web GUI Setup and Monitoring

Viewing Support Information


Viewing Contact Information
From the user interface of the D9859, choose Support > Contact Information. The
Contact Information page is displayed.

The Contact Information page displays all the Cisco customer support information.

252 OL-31980-01
Viewing Support Information

Viewing Diagnostic Logs


From the user interface of the D9859, choose Support > Diagnostic Logs. The
Diagnostic Logs page is displayed.

The Diagnostic Logs page displays all the system log messages with their dates and
times.
Click the arrow next to Set Date and Time column to sort by date and time.

Click Export to export the log history to a .csv file. The File Download dialog is
displayed. Click Save to save the file to your local drive.
Click Clear to clear the log history.

OL-31980 -01 253


Chapter 5 Web GUI Setup and Monitoring

Viewing the Usage Counters


From the user interface of the D9859, choose Support > Usage Counters. The Usage
Counters page is displayed.

The following table describes the Usage Counter Information:

Device Status Information Description

Production Date & Time Displays the date and time when the transcoder was
manufactured.

Last Power On Date and Time Displays the date and time when the transcoder was
powered up.

Lifetime Hours Powered Displays the number of hours since the last power-on.

Lifetime Reset Counter Displays the total number of times the transcoder has
been restarted.

Clearable Reset Counter Displays the number of restarts since the last time the
restart counter was cleared.
To clear or reset the Clearable Reset Count, click Clear
Reset Counter.

Hours Since Last Powered- Displays the total number of hours that the transcoder
On/Reset has been operating since the last power-on or restart.

Last Reset Reason Displays the reason for the last restart, i.e., power cycle
or manual reset.

Click Clear Reset Counter to clear the Clearable Reset Counter field and it resets
the counter back to 0.

254 OL-31980-01
Viewing Support Information

Viewing Operating Fan Speeds and Board Temperatures


From the user interface of the D9859, choose Support > Fans & Temperatures. The
Fans & Temperatures page is displayed.

The Current column displays the current operating temperature. The Maximum
column displays the maximum operating temperature that has been reached. The
Average column displays the average operating temperature. The values are
displayed in Degrees Celsius.
The FAN1 to FAN7 columns display the current speed of the seven fans in the D9859
transcoder.

OL-31980 -01 255


Chapter 5 Web GUI Setup and Monitoring

Viewing Alarm/Warning History


From the user interface of the D9859, choose System Settings > History. The Alarm
History page is displayed.
Note: The Alarm History page is also access by choosing Support > Alarm History.

The Alarm and Warning History page displays all the past system event messages
and their set and cleared dates and times. For more information on the alarm
messages, refer to D9859 Transcoder Alarm Messages (on page 260).
Click Clear Alarms/Warnings History to clear all the messages in the Fault History
table. Click Export to export the alarm history to a .csv file. The File Download
dialog is displayed. Click Save to save the file to your local drive.

256 OL-31980-01
Viewing Support Information

Loading a Software Version and License


From the user interface of the D9859, choose Support > Service Actions. The Service
Actions page is displayed.

The Collect Debug Support Data Export is used by Cisco Services only. Click
Export to create and save a diagnostics file.

Note: We recommend that you collect the debug support data prior to contacting
Cisco Services for any D9859 issues.
The S/W Version drop-down list allows you to select/load a different application
version to your transcoder. Click Select & Reboot to load the selected application
version and reboot the transcoder. Click Erase to remove the selected application
version. You will be prompted to continue or not. Press OK to continue the deletion.

Click Factory Reset to perform a reset of transcoder settings back to the factory set
(default) values. A warning message prompts you to confirm the operation. Click
OK to continue or No to cancel the operation.

Click Reboot Receiver to reboot the transcoder. You will be prompted to verify the
operation. Click Yes to reboot the transcoder or No to cancel the operation.

OL-31980 -01 257


Chapter 5 Web GUI Setup and Monitoring

Downloading the Software Application


In the Download APP area, click Choose File to select the new version of FPGA or
the D9859 Advanced Receiver Transcoder’s software application. The Open dialog
opens. Select the upgrade file and click Open. Click Download to download the
selected upgrade file. File formats that can be downloaded include Application
CDTs and FPGA CDTs.
During the upgrade, click Return to Browser (not recommended) to return to the
web browser. The application download continues. It is not recommended to
interrupt the upgrade during the application download. Click Download Status
Toggle to move between updating the Download Status data on the Versions page
and updating the download status on an external device.
Note: For application downloads, once the download is complete, the D9859
transcoder will reboot automatically. For FPGA downloads, you must click Reboot
Receiver to manually reboot the D9859 transcoder and complete the download. This
is to facilitate the typical case in which the user intends to flash the FPGA file (no
auto reboot) followed by an APP download (auto reboot).
Note: If you are downloading an older version of the software application, it is
recommended that you clear the browser cache prior to logging back in to the D9859
web GUI.

Downloading a Software License


If the unit is new from the factory, without any licenses loaded, it is recommended
that you wait three minutes after you first boot up the unit before downloading a
license file. If the unit has previously loaded licenses, it is recommended that you
wait ten minutes after you boot up the unit before downloading a new license file.
In the Download APP area, click Choose File to select the software license file. The
Open dialog opens. Select the license file and click Open. Click Download to
download the selected license file. You must wait approximately 100 seconds before
you can view the updated transcode license information. For more information on
license information, see Viewing Hardware Features and Base License Information
(on page 219).

258 OL-31980-01
6 Chapter 6
Service and Maintenance
Overview
This chapter gives information to assist you in upgrading firmware to
the D9859 Advanced Receiver Transcoder. It also describes how the
status of the D9859 transcoder is communicated via front panel LEDs.

In This Chapter
 D9859 Transcoder Alarm Messages ................................................260
 Power Supply Replacement.............................................................317

OL-31980 -01 259


Chapter 6 Service and Maintenance

D9859 Transcoder Alarm Messages


The Alarm LED on the front panel indicates whether the unit has triggered an alarm
or warning. A solid red signal for five seconds indicates a warning, and a flashing
red signal indicates an alarm. For more information, see About the Front Panel (on
page 34).

The status of the D9859 transcoder and its immediate surroundings is reported to the
front panel in the form of messages and alarms. You can enable or disable messages
in the Alarm/Warning settings.
The following table shows an alphabetical list of the available messages and their
default alarm status. The Set Messages and Clear Messages are displayed in the
Warning History when the messages are set or cleared respectively.
Note: Only alarm conditions can be used to trigger rear panel relays to control
external alarm equipment. Warnings are not associated with relay operations.

It is recommended that you collect the debug support data prior to contacting Cisco
customer support for any D9859 issues.

Alarms
Alarm Message Message Cause/Remedy Description Severity ID
Type

PSB non- Set PROD Cause: Production Device is in the Major 900
compliant incomplete or Access Reset WEAK state
PSB non- command was not after
compliant issued after production
production programming
programming was is complete.
completed.
Remedy: The
Access Reset
command should
be issued by the
user with PROD
credentials if the
device has not yet
been shipped to
the customer.
Otherwise, the
customer must
reset credentials
using the Front
Panel.

260 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

PSB non- Clear PSB compliant – – – 900


compliant

Pri Flash Fail Set Contact Cause: FLASH The FLASH Major 910
Customer Service driver operation device
(%s fail at %d) %s (one of ERASE, hardware
WRITE, failed.
BLANK_CHECK
or READ_WRITE)
failed on the
Primary (5514)
FLASH offset %d.
Remedy: Contact
Cisco customer
support.

Sec Flash Fail Set Contact Cause: FLASH The FLASH Major 920
Customer Service driver operation device
(%s fail at %d) %s (one of ERASE, hardware
WRITE, failed.
BLANK_CHECK
or READ_WRITE)
failed on the
Secondary (7109)
FLASH offset %d.
Remedy: Contact
Cisco customer
support.

Trans 1 Flash Set Contact Cause: FLASH The FLASH Major 930
Fail Customer Service driver operation device
(%s fail at %d) %s (one of ERASE, hardware
WRITE, failed.
BLANK_CHECK
or READ_WRITE)
failed on the
Transcoder 1
(Sat1) FLASH
offset %d.
Remedy: Contact
Cisco customer
support.

OL-31980 -01 261


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Trans 2 Flash Set Contact Cause: FLASH The FLASH Major 940
Fail Customer Service driver operation device
(%s fail at %d) %s (one of ERASE, hardware
WRITE, failed.
BLANK_CHECK
or READ_WRITE)
failed on the
Transcoder 2
(Sat2) FLASH
offset %d.
Remedy: Contact
Cisco customer
support.

Settings Lost Set Stored Cause: Corrupted The settings Major 950
configuration database record database
incomplete. was found while detects
Contact populating the corruption.
Customer DBR partition.
Service.
Remedy: Contact
Cisco customer
support.

App Startup Set <Version> Failed Cause: Errors An attempt to Major 960
Fault to start during software start <version>
startup. has failed.
Remedy: The unit
will revert back to
the previous
version within ten
minutes. If the
problem persists,
contact Cisco
customer support.

Signal Status Set ASI Signal - No Cause: Loss of ASI Link Minor 1000
Content ASI/RF lock. Loss Locked, but no
of Transport data. TS content.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.

262 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Signal Status Set RF Signal - No Cause: Loss of RF Tuner Minor 1000


Content ASI/RF lock. Loss locked, but no
of Transport data. TS content.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.

Signal Status Set Signal is lost Cause: Loss of Loss of signal Minor 1000
ASI/RF lock. Loss
of Transport data.
Invalid frequency
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.
Signal Status Set Tuning Cause: Loss of One of the Minor 1000
Parameters ASI/RF lock. Loss tuning
Invalid of Transport data. parameters is
Invalid frequency invalid
parameters.
External to IRD.
Remedy: Check
tuning parameters
and ASI/RF
cables.

Signal Status Clear Signal is locked – Signal OK Minor 1000

Signal Status Clear Tuning – Tuning Minor 1000


Parameters Valid parameters are
valid

Transcoder Set Transcode Not Cause: Possible No response Major 1500


Status Started: Restart hardware or was received
Timeout software fault. from the
transcoder
Remedy: Clear all
during the boot
alarms, reset the
process.
unit, and notify
Cisco customer
support if the
problem persists.

OL-31980 -01 263


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Transcoder Set Transcode Not Cause: Possible Unable to load Major 1500
Status Started: FPGA hardware or or execute the
failed to load software fault. transcoder
FPGA
Remedy: Clear all
software.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Transcoder Set Transcode Not Cause: Possible Transcoder Major 1500


Status Started: FPGA hardware or FPGA software
version mismatch software fault. version does
not match the
Remedy: Clear all
hardware
alarms, reset the
version.
unit, and notify
Cisco customer
support if the
problem persists.

Transcoder Set Transcode Not Cause: Possible Unable to load Major 1500
Status Started: Decoder hardware or or execute the
failed to load software fault. decoder
software.
Remedy: Clear all
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
Transcoder Set Transcode Not Cause: Possible Unable to load Major 1500
Status Started: Encoder hardware or or execute the
failed to load software fault. encoder
software.
Remedy: Clear all
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

264 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Transcoder Set Transcode Not Cause: Possible Transcoder Major 1500


Status Started: Invalid hardware or production
production software fault. information is
information corrupted.
Remedy: Clear all
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Transcoder Set Transcode Not Cause: Possible There was an Major 1500
Status Started: hardware or error
Communication software fault. establishing
Failure connection
Remedy: Clear all
with the
alarms, reset the
transcoder.
unit, and notify
Cisco customer
support if the
problem persists.

Transcoder Set Transcoder Not Cause: Possible Messages were Major 1500
Status Detected hardware or not received
software fault. from Transcode
on boot.
Remedy: Clear all
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
Transcoder Set Lost Contact Cause: Transcoder Messages were Major 1500
Status With Transcoder resetting. Possible not received
hardware or from
software fault. Transcoder
after it
Remedy: Clear all
previously
alarms, reset the
received
unit, and notify
messages.
Cisco customer
support if the
problem persists.

Transcoder Clear Transcoder – – Major 1500


Status Started

OL-31980 -01 265


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Transcoder Set POST reported Cause: Possible The transcoder Major 1600
Verification errors hardware issue. power-on self-
test reported
Remedy: Clear all
alarms, reset the errors.
unit, and notify
Cisco customer
support if the
problem persists.

Transcoder Set POST data Cause: Possible The transcoder Major 1600
Verification unavailable hardware issue. was unable to
read the results
Remedy: Clear all
of the power-
alarms, reset the
on self-test.
unit, and notify
Cisco customer
support if the
problem persists.

Transcoder Set Application Cause: Possible The transcoder Major 1600


Verification checksum failed hardware issue. software failed
verification.
Remedy: Clear all
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

TEB State Set Error state Cause: There is a The transcoder Major 2000
transcoder board board is in an
error. error state.
Remedy: Clear all
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
TEB State Set TEB Application Cause: There is a Application Major 2000
mismatch transcoder board version
error. mismatch
between the
Remedy: Clear all
transcoder
alarms, reset the
board and the
unit, and notify
main board.
Cisco customer
support if the
problem persists.

TEB State Clear Fault cleared – – Major 2000

266 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

PE n: ISE Not Set Channel is not Cause: The Program Minor 3000
Auth authorized channel is unauthorized 4000
unauthorized for because the tier 5000
the current bits do not 6000
program. match. 7000
8000
Remedy: Contact
9000
your (uplink)
10000
service provider to
determine 10009-10032
whether you are
authorized to
receive the current
program.

PE n: ISE Not Set Channel requires Cause: The Program is Minor 3000
Auth an authorization channel is unauthorized 4000
key unauthorized for because the 5000
the current unit does not 6000
program. have an 7000
authorization 8000
Remedy: Contact
key. 9000
your (uplink)
10000
service provider to
10009-10032
determine
whether you are
authorized to
receive the current
program.

PE n: ISE Not Set Channel is Cause: The Program is Minor 3000


Auth blacked out channel is unauthorized 4000
unauthorized for because at a 5000
the current minimum, it 6000
program. needs to match 7000
one blackout 8000
Remedy: Contact
code. 9000
your (uplink)
10000
service provider to
10009-10032
determine
whether you are
authorized to
receive the current
program.

OL-31980 -01 267


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

PE n: ISE Not Set Channel uses an Cause: Non-SA Minor 3000


Auth unknown CA Conditional access conditional 4000
system not supported. access system. 5000
6000
Remedy: Contact
7000
your (uplink)
8000
service provider to
9000
determine
10000
whether you are
authorized to 10009-10032
receive the current
program at this
time.

PE n: ISE Not Set Channel Cause: There is Minor 3000


Auth authorization Conditional access mismatch in 4000
refused not supported. the Conditional 5000
access. 6000
Remedy: Contact
7000
your (uplink)
8000
service provider to
9000
determine
10000
whether you are
10009-10032
authorized to
receive the current
program at this
time.

PE n: ISE Not Set Channel requires Cause: Conditional Minor 3000


Auth an IRD with CA Conditional access access is not 4000
support not supported. supported. 5000
6000
Remedy: Contact
7000
your (uplink)
8000
service provider to
9000
determine
10000
whether you are
10009-10032
authorized to
receive the current
program at this
time.

PE n: ISE Not Set Channel requires Cause: Hardware Hardware Minor 3000
Auth the PE to have an issue. issue. 4000
ISE 5000
Remedy: Clear
6000
alarms, reset unit,
7000
and notify Cisco
8000
customer support
9000
if problem
10000
persists.
10009-10032

268 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

PE n: ISE Not Set Channel Cause: Uplink Uplink Minor 3000


Auth Unavailable - configuration configuration 4000
LEC timeout issue. issue. 5000
6000
Remedy: Contact
7000
your (uplink)
8000
service provider to
9000
determine
10000
whether the LEC
GDS data is being 10009-10032
provided in the
stream.

PE n: ISE Not Clear Fault Reset – – Minor 3000


Auth 4000
5000
6000
7000
8000
9000
10000
10009-10032

PE n: ISE Not Clear Channel is – – Minor 3000


Auth authorized 4000
5000
6000
7000
8000
9000
10000
10009-10032

PE n: Loss of Set Loss of input Cause: Loss of Loss of input. Minor 11000
Input detected input. 12000
13000
Remedy: Ensure
14000
input has a valid
15000
stream.
16000
17000
18000
18009-18032

OL-31980 -01 269


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

PE n: Loss of Clear Fault reset – – Minor 11000


Input 12000
13000
14000
15000
16000
17000
18000
18009-18032

Digital Program Set PID Collision Cause: Uplink Two source Minor 19000
Mapping settings may have service PIDs
changed since are being
setting up the unit. mapped to the
Please check your same output
DPM settings. PID. This will
cause data
Remedy: Correct
corruption in
the DPM settings.
the stream.
Check the uplink
to find the
appropriate
system settings.

Digital Program Set Program Cause: Uplink Two source Minor 19000
Mapping Collision settings may have channel
changed since numbers are
setting up the unit. being mapped/
Please check your passed to the
DPM settings. same channel
number in the
Remedy: Correct
output.
the DPM settings.
Check the uplink
to find the
appropriate
system settings.

Digital Program Set Mode-i PMT out Cause: Uplink PMT PID to be Major 19000
Mapping of range settings may have used for Mode-
changed since i is outside of
setting up the unit. valid MPEG
Please check your PID range.
DPM settings.
Remedy: Correct
the DPM settings.
Check the uplink
to find the
appropriate
system settings.

270 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Digital Program Clear Digital Program – – Major 19000


Mapping Mapping - OK

Transcoding Set Transcoding Cause: Possible Unexpected Minor 19500


Status Halted: SW hardware or software
version mismatch software issue. version
running on
Remedy: Reselect
transcoder
desired
application, clear
alarms, reset the
unit, notify Cisco
customer support
if problem
persists.

Transcoding Set Transcoding Cause: Possible Transcoder Minor 19500


Status Halted: hardware or software in
Transcoder out of software issue. unexpected
sync state.
Remedy: Reselect
desired
application, clear
alarms, reset the
unit, notify Cisco
customer support
if problem
persists.
Transcoding Clear Transcoding – – Minor 19500
Status operational

Shutdown Event Set DL APP Cause: User New Major 20000


REBOOT request requires application
reboot or internal downloaded,
system error. system requires
reboot.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

OL-31980 -01 271


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Shutdown Event Set User requested Cause: User Runnable Major 20000
FPGA change request requires FPGA change
reboot or internal requires reboot.
system error.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

Shutdown Event Set User requested Cause: User Runnable Major 20000
APP change request requires application
reboot or internal change requires
system error. reboot.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

Shutdown Event Set User requested Cause: User Factory reset Major 20000
factory reset request requires requires reboot.
reboot or internal
system error.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

272 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Shutdown Event Set User requested Cause: User User reboot Major 20000
reboot request requires request.
reboot or internal
system error.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

Shutdown Event Set User requested Cause: User Restore Major 20000
service restore request requires operation
reboot or internal required restart
system error.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

Shutdown Event Set PRODUCTION - Cause: User Reboot after Major 20000
Protect Flash request requires production
reboot or internal tables
system error. removed.
Remedy: If it is an
internal system
error fault, clear
alarms, reset the
unit, notify Cisco
customer support
if the problem
persists.

Shutdown Event Set I2C Failure Cause: Possible Internal system Major 20000
software/hardwar error.
e issue.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

OL-31980 -01 273


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Shutdown Event Set WDOG: FPGA Cause: Possible FPGA has not Major 20000
not loaded software/hardwar been loaded.
e issue.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set osal_SetDataFor Cause: Possible Application Major 20000


AllTasks software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set aw_LoadFaultLis Cause: Possible Application Major 20000


t software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set osal_Init Cause: Possible Application Major 20000


software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set NVS FLASH Cause: Possible Application Major 20000
mounted software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

274 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Shutdown Event Set DB_Table_Cl::po Cause: Possible Application Major 20000


pulateNvsRecord software issue. initialization
s error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set STAPI_Init Cause: Possible Application Major 20000


software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set dprm startup Cause: Possible Application Major 20000
software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set dprm clear Cause: Possible Application Major 20000
startup software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set DB_Array32_Cl Cause: Possible Application Major 20000
init failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

OL-31980 -01 275


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Shutdown Event Set DB_FlagArray32_ Cause: Possible Application Major 20000


Cl init failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Wrong DB Item Cause: Possible Application Major 20000
detected: item = software issue. initialization
AAA, table = BBB error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set DB_Item_Cl::add Cause: Possible Application Major 20000


Item() failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Memory Cause: Possible Application Major 20000


allocation error software issue. initialization
on DB table error.
Remedy: Clear
construction
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set DB_Table_Cl::ad Cause: Possible Application Major 20000
dTable() failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

276 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Shutdown Event Set DB_Table_Cl::ad Cause: Possible Application Major 20000


dItem() failed: software issue. initialization
too many DB error.
Remedy: Clear
Items alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set DBT Init Failed: Cause: Possible Application Major 20000
AAA software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Framework Cause: Possible Application Major 20000


Registration software issue. initialization
Error error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set 7109 exception! Cause: Possible Application Major 20000
Code = X, software issue. initialization
Address = Y, error.
Remedy: Clear
Task = Z
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set Memory Error: Cause: Possible Application Major 20000
AAA, Phase X software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

OL-31980 -01 277


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Shutdown Event Set Time Control Cause: Possible Application Major 20000
object creation software issue. initialization
failed error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Wrong UIC Item Cause: Possible Application Major 20000
detected: item = software issue. initialization
AAA, table BBB error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Memory Cause: Possible Application Major 20000


allocation error software issue. initialization
on UIC table error.
Remedy: Clear
construction
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Error adding UIC Cause: Possible Application Major 20000
table(AAA) software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set HTTP - Cause: Possible Application Major 20000
http_init4() software issue. initialization
FAILED to create error.
Remedy: Clear
partition
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

278 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Shutdown Event Set http_init4: Cause: Possible Application Major 20000


FAILED to software issue. initialization
allocate scratch error.
Remedy: Clear
buffer alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set HTTP - Cause: Possible Application Major 20000


http_init4() software issue. initialization
FAILED to error.
Remedy: Clear
allocate memory
alarms, reset unit,
from AVMEM
notify Cisco
Partition
customer support
if problem
persists.

Shutdown Event Set UD - Cause: Possible Application Major 20000


ud_init_phase_4( software issue. initialization
) FAILED to error.
Remedy: Clear
allocate memory
alarms, reset unit,
from System
notify Cisco
Partition
customer support
if problem
persists.

Shutdown Event Set UD - Cause: Possible Application Major 20000


ud_init_phase_4( software issue. initialization
) FAILED to error.
Remedy: Clear
create partition
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set '--- Cause: Possible Application Major 20000
COMPONENT software issue. initialization
'AAA' FAILED error.
TO INIT IN Remedy: Clear
alarms, reset unit,
PHASE X,
notify Cisco
rc=NNN
customer support
if problem
persists.

OL-31980 -01 279


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Shutdown Event Set VBI DB creation Cause: Possible Application Major 20000
failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set VBI DB allocation Cause: Possible Application Major 20000
failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set VBI Status DB Cause: Possible Application Major 20000
creation failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set VBI Status DB Cause: Possible Application Major 20000
allocation failed software issue. initialization
error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.
Shutdown Event Set UIC_ENUM_CL Cause: Possible Application Major 20000
given invalid software issue. initialization
ENUM_ST: item error.
= AAA, table = Remedy: Clear
alarms, reset unit,
BBB, problem
notify Cisco
with primary: X
customer support
if problem
persists.

280 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Shutdown Event Set FW: Memory or Cause: Possible Internal system Major 20000
List Full software issue. error.
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Framework Cause: Possible Internal system Major 20000
Registration software issue. error.
Error
Remedy: Clear
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

Shutdown Event Set Watchdog 'AAA' Cause: Possible Software Major 20000
has expired software issue. detected an
error in
Remedy: Clear
operation.
alarms, reset unit,
notify Cisco
customer support
if problem
persists.

System Startup Set System Startup Cause: The unit Indicates that Major 20100
has started up and the decoder has
it indicates an started up. This
expected or alarm will clear
unexpected reset. itself after one
second.
Remedy: If a
startup was
unexpected, check
for last reset cause.
Notify Cisco
customer support
if problem
persists.

OL-31980 -01 281


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

SMI Setup Set Phase lock error Cause: Hardware SDRAM on Major 21000
on SMI SDRAM Issue. SMI bus not
working.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

SMI Setup Set SMI SDRAM Cause: Hardware SDRAM on Major 21000
exhaust test Issue. SMI bus not
failed working.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

SMI Setup Clear SMI SDRAM SDRAM on Major 21000


setup successful SMI Bus OK.

SMI Setup Clear SMI SDRAM SDRAM on Major 21000


exhaust test SMI Bus OK.
passed

LMI setup Set LMI SDRAM Cause: Hardware DDR RAM on Major 22000
exhaust test issue. LMI bus not
failed working.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
LMI setup Clear LMI Video DDR RAM on Major 22000
SDRAM exhaust LMI bus OK.
test passed

Param Storage Set DB NVS flushing Cause: Hardware Non-volatile Major 23000
ignored issue. storage system
failed to update
Remedy: Clear
fully.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

282 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Param Storage Set RAM flush to Cause: Hardware Non-volatile Major 23000
NVS failed issue. storage system
failed to update
Remedy: Clear
alarms, reset the fully.
unit, and notify
Cisco customer
support if the
problem persists.

Param Storage Set DB Factory Reset Cause: Standard Non-volatile Major 23000
in progress operation. storage system
operation in
Remedy: Clear
progress.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Param Storage Set DB Total Reset in Cause: Standard Non-volatile Major 23000
progress operation. storage system
operation in
Remedy: Clear
progress.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Param Storage Set DB NVS flush in Cause: Standard Non-volatile Major 23000
progress operation. storage system
operation in
Remedy: Clear
progress.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
Param Storage Set DB Populate in Cause: Standard Non-volatile Major 23000
progress operation. storage system
operation in
Remedy: Clear
progress.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

OL-31980 -01 283


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Param Storage Set DB Factory Reset Cause: Hardware Non-volatile Major 23000
failed issue. storage system
failed during
Remedy: Clear
alarms, reset the operation.
unit, and notify
Cisco customer
support if the
problem persists.

Param Storage Set DB Total Reset Cause: Hardware Non-volatile Major 23000
failed issue. storage system
failed during
Remedy: Clear
operation.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Param Storage Set DB Populate Cause: Hardware Non-volatile Major 23000


failed issue. storage system
failed during
Remedy: Clear
operation.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Param Storage Set DB NVS flush Cause: Hardware Non-volatile Major 23000
failed issue. storage system
failed during
Remedy: Clear
operation.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
Param Storage Clear DB flushing – Successful NVS Major 23000
completed update.
Param Storage Clear DB Factory Reset – Non-volatile Major 23000
completed storage system
operation
successful

Param Storage Clear DB Total Reset – Non-volatile Major 23000


completed storage system
operation
successful

284 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Param Storage Clear DB NVS flush – Non-volatile Major 23000


completed storage system
operation
successful

Param Storage Clear DB Populate – Non-volatile Major 23000


completed storage system
operation
successful

Flash Storage Set RECORD: init Cause: Hardware Non-volatile Major 24000
failed issue. storage system
corrupted.
Remedy:
Possible loss of
Clear alarms, reset
configuration.
the unit, and
notify Cisco
customer support
if the problem
persists.

Flash Storage Set RECORD Cause: Hardware NVS Major 24000


MANAGER: issue. Corruption,
Record contents and loss of
Remedy:
check error, configuration
Clear alarms, reset
erasing all data
the unit, and
notify Cisco
customer support
if the problem
persists.

Flash Storage Set RECORD: sector Cause: Hardware NVS Major 24000
setup check error, issue. Corruption,
erasing sector and loss of
Remedy:
sector data
Clear alarms, reset
the unit, and
notify Cisco
customer support
if the problem
persists.

Flash Storage Clear RECORD: init – – Major 24000


done

OL-31980 -01 285


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

LNB PS Set LNBPS: No Load Cause: Possible LNB power Minor 25000
wiring or overload
hardware issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

LNB PS Set LNBPS: Over Cause: Possible LNB power Minor 25000
Temperature wiring or overload
hardware issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

LNB PS Set LNBPS: Over Cause: Possible LNB power Minor 25000
Loaded wiring or overload
hardware issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.
LNB PS Set LNBPS: Short Cause: Possible LNB power Minor 25000
Circuit wiring or overload
hardware issue.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

LNB PS Clear LNBPS: Normal – LNB power OK Minor 25000

LNB PS Clear LNBPS: Disabled – – Minor 25000

LNB PS Clear LNBPS: Off – – Minor 25000

286 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Flash Sector Set Check setting. Cause: A sector on FLASH Minor 25500
Error Counted %d FLASH %s (Pri, recovered after
events on %s. See Sec,Trans 1 or unexpected
User Manual Trans 2) was corruption.
found corrupted
on power-up,
which was not a
result of an
interrupted erase.
The problem
happened %d
times on this
FLASH, during a
lifetime.
Remedy: Check if
the desired
application is
sunning and if the
settings are valid.

Signal Quality Set Audio Muted Cause: RF Signal Signal is locked Minor 26000
due to RF noise quality is poor due but BER is
to interference or beyond Audio
signal level issues. muting
threshold.
Remedy: Check
RF settings, re-aim
dish, and add
signal amplifier.

Signal Quality Set Unstable RF Cause: RF Signal Signal lock Minor 26000
Signal quality is poor due status is
to interference or toggling
signal level issues. frequently.
Remedy: Check
RF settings, re-aim
dish, and add
signal amplifier.

Signal Quality Set Poor Quality RF Cause: RF Signal Signal is locked Minor 26000
Signal quality is poor due but BER is
to interference or beyond muting
signal level issues. threshold.
Remedy: Check
RF settings, re-aim
dish, and add
signal amplifier.

OL-31980 -01 287


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Signal Quality Clear Signal Quality – – Minor 26000


Fault Cleared

Signal Quality Clear Audio Unmuted – – Minor 26000

Transport Set PTI lockup Cause: Possible Programmable Minor 27000


Processing software issue. transport input
module
Remedy: Clear
stopped
alarms, reset unit,
processing any
and notify Cisco
customer support data packet.
if problem
persists.

Transport Clear PTI running – – Minor 27000


Processing

Version Set Version Cause: The Version Major 27400


Mismatch Mismatch App5514 version mismatch
between does not match between code
5514/7109 the App7109 running 5514
version. and 7109
versions.
Remedy:
Download code
with identical
App5514 and
App7109 versions.
DL: TEB Comms Set Intra-processor Cause: Transcoder Internal Major 27500
Failure comms failure board issue. communication
failure.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if problem
persists.

DL:NVS Flash Set APP5514 Flash Cause: Possible Failed to read Major 27600
Failure Write Failed hardware or or write flash
software issue. memory
Remedy: Clear
alarms, reset unit,
and notify Cisco
customer support
if problem
persists.

288 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

DL:NVS Flash Set APP/SAT7109/P Cause: Possible Failed to read Major 27600
Failure PC CRC/Write hardware or or write flash
has Failed software issue. memory
Remedy: Clear
alarms, reset unit,
and notify Cisco
customer support
if problem
persists.

Temperature Set Temperature Cause: Room Temperature is Major 28000


Alarm over Alarm temperature too above safe
threshold high, or air flow is operating
blocked. range.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.
Temperature Clear Temperature – Temperature is Major 28000
Alarm normal within the safe
operating
range.
Fan Set Fan RPM Alarm Cause: Hardware Fan RPM out of Major 29000
issue. normal
operating
Remedy: Unit
range.
should be
returned to Cisco
customer support
as soon as
possible.

Fan Clear Fans Operational – – Major 29000

OL-31980 -01 289


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

FPGA Set Temperature Cause: Room FPGA Major 30000


Temperature over Alarm temperature too temperature is
Alarm threshold high, or air flow is above safe
blocked. operating
range.
Remedy: Check
openings on front
and rear panels for
blockage. Lower
room temperature
or improve air
flow to device.

FPGA Clear Temperature – FPGA Major 30000


Temperature normal temperature is
Alarm within the safe
operating
range.

TXB FPGA Set Temperature Cause: Room The transcoder Major 31100
Temper. Alarm over Alarm temperature too board FPGA
threshold high, or air flow is temperature is
blocked. above the safe
operating
Remedy: Check
range.
the openings on
the front and rear
panels for
blockage, assess
the room
temperature.
Lower the room
temperature or
improve air flow
to the device.
TXB FPGA Clear Temperature The transcoder Major 31100
Temper. Alarm normal board FPGA
temperature is
within the safe
operating
range.

290 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

TXB ENC Set Temperature Cause: Room The transcoder Major 33100
Temper. Alarm over Alarm temperature too board encoder
threshold high, or air flow is temperature is
restricted. above safe
operating
Remedy: Check
the openings on range.
front and rear
panels for
blockage, assess
the room
temperature.
Lower the room
temperature or
improve air flow
to the device.

TXB ENC Clear Temperature – The transcoder Major 33100


Temper. Alarm normal board encoder
temperature is
within the safe
operating
range.

ASI Out Status Set ASI Overflow. Cause: Uplink Current Minor 34000
Output Muted. settings may have transport rate
Reduce content. changed since exceeds
setup of the unit. configured rate
Variable Bit for ASI output.
Rate/Statmuxed Output has
streams may be in been muted to
use. protect
downstream
Remedy: Increase
devices.
the output rate,
drop unreferenced
content in DPM
Options, and/or
drop programs
not needed for
downstream
devices. Contact
your (uplink)
service provider to
verify the
expected bit rate
settings.

ASI Out Status Clear ASI Output – – Minor 34000


Restored

OL-31980 -01 291


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

MPoIP Status Set MPEGoIP Cause: Uplink Current Minor 35000


Overflow. settings may have transport rate
Output Muted. changed since the exceeds
Reduce content. setup of the unit. configured rate
Variable Bit for MPEG over
Rate/Statmuxed IP output. The
streams may be in output has
use. been muted to
protect the
Remedy: Increase
downstream
output rate, drop
unreferenced devices.
content in DPM
Options, drop
programs not
needed for
downstream
devices. Contact
uplink to verify
expected bit rate
settings.

MPoIP Status Clear MPEGoIP Output – – Minor 35000


Restored

Boot Host Set KB not accessible Cause: Hardware KB is not Major 36000
issue detected by
Boot code.
Remedy: Clear
alarms, reset unit,
and notify Cisco
customer support
if the problem
persists.

Boot Host Set LCD not Cause: Hardware LCD is not Major 36000
connected issue detected by
Boot code.
Remedy: Clear
alarms, reset unit,
and notify Cisco
customer support
if the problem
persists.

292 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Boot Host Set FLASH Not Cause: Hardware Flash memory Major 36000
Found issue not detected.
Remedy: Clear
alarms, reset unit,
and notify Cisco
customer support
if the problem
persists.

Boot Host Set EMI SDRAM Test Cause: Hardware RAM Failure - Major 36000
Failed issue memory testing
failed.
Remedy: Clear
alarms, reset unit,
and notify Cisco
customer support
if the problem
persists.

Boot Host Set BOOT Invalid Cause: Hardware Boot SW Major 36000
issue cannot be read
from memory
Remedy: Clear
correctly.
alarms, reset unit,
and notify Cisco
customer support
if the problem
persists.

Boot Host Set APP Invalid Cause: Hardware Application SW Major 36000
issue cannot be read
from memory
Remedy: Clear
correctly.
alarms, reset unit,
and notify Cisco
customer support
if the problem
persists.
Boot Host Clear BOOT passed – – Major 36000

Boot Secondary Set BOOT Invalid Cause: Hardware Boot SW Major 37000
issue. cannot be read
from memory
Remedy: Clear
correctly.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

OL-31980 -01 293


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Boot Secondary Set FPGA Invalid Cause: Hardware FPGA Image Major 37000
issue. cannot be read
from memory
Remedy: Clear
alarms, reset the correctly.
unit, and notify
Cisco customer
support if the
problem persists.

Boot Secondary Set APP Invalid Cause: Hardware Application SW Major 37000
issue. cannot be read
from memory
Remedy: Clear
correctly.
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

Boot Secondary Clear BOOT passed – – Major 37000

Decoder Set DB Startup failed Cause: Hardware Transfer of Major 38000


Processor Start issue. operational
parameters to
Remedy: Clear
secondary
alarms, reset the
processor
unit, and notify
failed.
Cisco customer
support if the
problem persists.
Decoder Set App Transfer Fail Cause: Hardware Transfer of Major 38000
Processor Start issue. Application
software to
Remedy: Clear
second
alarms, reset the
processor was
unit, and notify
not correctly
Cisco customer
completed.
support if the
problem persists.
Decoder Set No Response Cause: Hardware Secondary Major 38000
Processor Start issue. processor not
responding.
Remedy: Clear
alarms, reset the
unit, and notify
Cisco customer
support if the
problem persists.

294 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Decoder Set Synchronization Cause: Hardware Communicatio Major 38000


Processor Start Failure issue. n with
secondary
Remedy: Clear
processor
alarms, reset the
failing.
unit, and notify
Cisco customer
support if the
problem persists.

Decoder Clear Boot passed – – Major 38000


Processor Start

LEC Timeout Set LEC Table Cause: Possible ECT Table is Major 38500
Missing/timeout: LEC Server or not received in
channels Uplink issue. the GDS
currently stream.
Remedy: Check
unavailable
LEC Server setup
and uplink
configuration for
GDS PID setup.
Clear alarm and
notify Cisco
customer support
if the problem
persists.
LEC Timeout Clear LEC received – – Major 38500

FPGA status Set FPGA Init failed Cause: Hardware FPGA setup Major 39000
to go high issue. failure or the
FPGA binary
Remedy: Clear
identity does
alarms, reset the
not match the
unit, notify Cisco
FPGA registers.
customer support
if the problem
persists.

FPGA status Set FPGA Init and Cause: Hardware FPGA setup Major 39000
Done failed to go issue. failure or the
low FPGA binary
Remedy: Clear
identity does
alarms, reset the
not match the
unit, notify Cisco
FPGA registers.
customer support
if the problem
persists.

OL-31980 -01 295


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

FPGA status Set FPGA Init went Cause: Hardware FPGA setup Major 39000
LOW (CRC error) issue. failure or the
FPGA binary
Remedy: Clear
identity does
alarms, reset the
not match the
unit, notify Cisco
customer support FPGA registers.
if the problem
persists.

FPGA status Set FPGA Done Cause: Hardware FPGA setup Major 39000
failed to go high issue. failure or the
FPGA binary
Remedy: Clear
identity does
alarms, reset the
not match the
unit, notify Cisco
FPGA registers.
customer support
if the problem
persists.

FPGA status Set SW ver outside Cause: Hardware FPGA setup Major 39000
upper or lower issue. failure or the
limit FPGA binary
Remedy: Clear
identity does
alarms, reset the
not match the
unit, notify Cisco
FPGA registers.
customer support
if the problem
persists.

FPGA status Set FPGA ID does Cause: Hardware FPGA setup Major 39000
not match FPGA issue. failure or the
DESIGNATION FPGA binary
Remedy: Clear
identity does
alarms, reset the
not match the
unit, notify Cisco
FPGA registers.
customer support
if the problem
persists.
FPGA status Set FPGA ID does Cause: Hardware FPGA setup Major 39000
not match HW issue. failure or the
FPGA ID FPGA binary
Remedy: Clear identity does
alarms, reset the
not match the
unit, notify Cisco
FPGA registers.
customer support
if the problem
persists.

FPGA status Clear FPGA loaded – – Major 39000


successfully and
reset

296 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

PE <n>: CA Set No PowerVU Cause: The currentCA System Minor 93000-93031


System Error support channel assigned present in the
to this Program currently
Entry is scrambledselected
using an channel cannot
unsupported CA be descrambled
System. due to no
PowerVU ISE
Remedy: Check to
ensure that the support.
proper channel is
assigned to this
Program Entry.

PE <n>: CA Set No Matching Cause: The currentCA System Minor 93000-93031


System Error CAM channel assigned present in the
to this Program currently
Entry is scrambledselected
using an channel cannot
unsupported CA be descrambled
System. due to no
PowerVU ISE
Remedy: Check to
support.
ensure that the
proper channel is
assigned to this
Program Entry.

PE <n>: CA Clear Fault cleared – – Minor 93000-93031


System Error

Xcode License Set Working Cause: Possible The number of Major 93106
Fault transcoders are hardware failure. working
fewer than the transcoders are
Remedy: Contact
licenses fewer than the
Cisco customer
number of
support.
licenses
provisioned

Xcode License Clear Transcoder – – Major 93106


Fault working

OL-31980 -01 297


Chapter 6 Service and Maintenance

Alarm Message Message Cause/Remedy Description Severity ID


Type

Xcode Load Set Failed on PE(s): Cause: Transcoder The software is Major 94008
Status x,y,z chip is not unable to
functional. This is initialize the
a possible transcoder
hardware issue. chip.
Remedy: Reboot
the unit. If the
issue is
intermittent, the
condition may be
cleared by the
reboot.

Xcode Load Clear Fault cleared – – Major 94008


Status

Transcoder Set Failed on PE(s): Cause: Transcoder The software is Major 94010
Reset x,y,z chip is not unable to
functional. This is initialize the
a possible transcoder chip
hardware issue.
Remedy: Reboot
the unit. If the
issue is
intermittent, the
condition may be
cleared by the
reboot.

Transcoder Clear Fault cleared – – Major 94010


Reset

Transcoder Set Failure to load or Cause: Possible Attempt to Major 94011


Firmware Init Transcoder problem with the load or re-load
firmware transcoder. the transcoder
firmware has
Remedy: Power- not been
cycle the unit. If successful and
the problem the transcoded
persists or output will not
occurs be present.
frequently,
contact Cisco
customer
support.
Transcoder Clear Load and Init – – Major 94011
Firmware Completed

298 OL-31980-01
Alarm Message Message Cause/Remedy Description Severity ID
Type

Disaster Set Disaster declared Cause: One or A disaster is Major 98000


Declared more of the detected.
following is
detected: RF lock
loss, unstable RF
signal, and/or
transport loss (RF
locked, but no
transport stream
packet received)
Remedy: A valid
signal.

Disaster Reset No disaster – Disaster Major 98000


Declared recovery
feature is
cleared with a
valid signal.

Warnings
Warning Message Message Cause/Remedy Description ID
Type

Transcoding Set Transcoding Cause: Possible software The transcoder has 39500
Condition Error: Decoder issue. lost connection with
timeout the decoder.
Remedy: Clear alarms,
reset the unit, and notify
Cisco customer support
if the problem persists.

Transcoding Set Transcoding Cause: Possible software The transcoder 39500


Condition Error: Encoder issue. encoder encountered
an error.
Remedy: Clear alarms,
reset the unit, and notify
Cisco customer support
if the problem persists.

Transcoding Set Transcoding Cause: Possible software The transcoder has 39500
Condition Error: Encoder issue. lost connection with
timeout the encoder.
Remedy: Clear alarms,
reset the unit, and notify
Cisco customer support
if the problem persists.

OL-31980 -01 299


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

Transcoding Set Transcoding Cause: Possible software No response was 39500


Condition configuration issue. received from the
error: timeout transcoder to
Remedy: Clear alarms,
configuration
reset the unit, and notify
message.
Cisco customer support
if the problem persists.

Transcoding Set Transcoding Cause: Possible software Unable to send the 39500
Condition configuration issue. configuration to the
error: socket transcoder.
Remedy: Clear alarms,
error reset the unit, and notify
Cisco customer support
if the problem persists.

Transcoding Set Transcoding Cause: Possible software The transcoder 39500


Condition retrieve error: issue. refused to return
refused requested information.
Remedy: Clear alarms,
reset the unit, and notify
Cisco customer support
if the problem persists.

Transcoding Set Transcoding cmd Cause: Possible software The transcoder 39500
Condition msg error: issue. refused a given
refused command.
Remedy: Clear alarms,
reset the unit, and notify
Cisco customer support
if the problem persists.

Transcoding Set Transcoding Cause: Configuration The transcoder 39500


Condition config error: may have an invalid refused the
refused parameter, or possible configuration.
software issue. The
transcoder refused the
configuration.
Remedy: Check
configuration, clear
alarms, reset the unit,
and notify Cisco
customer support if
problem persists.

Transcoding Clear Transcoding cmd – – 39500


Condition msg operational
Transcoding Clear Transcoding – – 39500
Condition retrieve
operational

300 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

Transcoding Clear Transcoding – – 39500


Condition config
operational

Transcoding Clear Transcoding – – 39500


Condition operational

ASI TS Set ASI Output Cause: Uplink settings The output rate is 40000
Overflow Overflow may have changed since higher than level set
setting up the unit. by the user.
Variable bit rate or
statmuxed streams may
be in use.
Remedy: Increase the
output rate, drop
unreferenced content in
DPM Options, and drop
the programs that are
not needed for
downstream devices.
Contact your (uplink)
service provider to
verify the expected bit
rate settings.

ASI TS Clear ASI Output – – 40000


Overflow Overflow
Cleared

Transport Error Set Continuity Count Cause: Possible uplink Transport packet 42000
Error or signal issue. continuity count
jumped. Possible
Remedy: Clear
packet loss.
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.

Transport Error Set Buffer Overflow Cause: Possible uplink The transport stream 42000
or signal issue. is faster than the
maximum buffer or
Remedy: Clear
the decode engines are
warnings, reset the unit,
having difficulty
and notify Cisco
handling the data sent
customer support if the
to them.
problem persists.

OL-31980 -01 301


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

Transport Error Set Transport Error Cause: Possible uplink Transport packets are 42000
Indicator or signal issue. marked as "errored"
upstream of the
Remedy: Clear
warnings, reset the unit, decoder.
and notify Cisco
customer support if the
problem persists.

Transport Error Set Transport Rate Cause: Uplink settings The output rate is 42000
Error: FPGA may have changed since higher than level set
Overflow setting up the unit. by the user.
Remedy: Increase the
output rate, drop
unreferenced content in
DPM Options, and/or
drop programs not
needed for downstream
devices. Contact your
(uplink) service provider
to verify the expected bit
rate settings.

Transport Error Clear Continuity Count – Trap expires after 30 42000


Error Cleared seconds.

Transport Error Clear Buffer Overflow – Trap expires after 30 42000


Cleared seconds.

Transport Error Clear Transport Error – Trap expires after 30 42000


Indicator Cleared seconds.

Transport Error Clear Transport Rate – Trap expires after 30 42000


Error: FPGA seconds.
Overflow
Cleared

Video Format Set Video format – Video Format 43000


Mismatch mismatch Mismatch.

Video Format Clear Video format – – 43000


Mismatch match

302 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

Temperature Set Temperature Cause: Room Temperature is above 44000


Warning over Warning temperature too high, or normal operating
threshold air flow is blocked. range.
Remedy: Check
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.

Temperature Clear Temperature – Temperature is within 44000


Warning normal the normal operating
range.

FPGA Set Temperature Cause: Room FPGA temperature is 45000


Temperature over Warning temperature is too high, above normal
Warning threshold or air flow is blocked. operating range.
Remedy: Check the
openings on front and
rear panels for blockage.
Lower the room
temperature or improve
air flow to the device.

FPGA Clear Temperature – FPGA temperature is 45000


Temperature normal within the normal
Warning operating range.
TXB FPGA Set Temperature Cause: Room TXB FPGA 46000
Temper. over Warning temperature too high, or temperature is above
Warning threshold air flow is restricted. normal operating
range.
Remedy: Check
openings on front and
rear panels for blockage,
assess room
temperature. Lower
room temperature or
improve air flow to
device.

TXB FPGA Clear Temperature – TXB FPGA 46000


Temper. normal temperature is within
Warning the normal operating
range.

OL-31980 -01 303


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

TXB ENC Set Temperature Cause: Room TXB encoder 46000


Temper. over Warning temperature too high, or temperature is above
Warning threshold air flow is restricted. normal operating
range.
Remedy: Check
openings on front and
rear panels for blockage,
assess room
temperature. Lower
room temperature or
improve air flow to
device.

TXB ENC Clear Temperature – TXB encoder 46000


Temper. normal temperature is within
Warning the normal operating
range.

VBI Data Set 2nd VBI PID Cause: Uplink Conflicting VBI data 49000
attempt to write configuration issue. on second VBI PID.
same line
Remedy: Contact uplink
to verify expected VBI
settings.

VBI Data Clear Line Collision – – 49000


Cleared

TDT timeout # Set TDT timed out Cause: Uplink is not Time Date Table was 50000
sending or is sending never received.
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

TDT timeout # Set TDT is lost Cause: Uplink is not No longer receiving 50000
sending or is sending Time Date.
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

TDT timeout # Clear TDT fault cleared – – 50000

304 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

SDT timeout # Set SDT # timed out Cause: Uplink is not Service Description 51000
sending or is sending Table was never 52000
intermittently. received. 53000
54000
Remedy: Clear warning.
55000
If the problem persists,
56000
determine if uplink is
57000
sending the current SI
58000
information table.
Disable the warning if
not using the table.

SDT timeout # Set SDT # is lost Cause: Uplink is not No longer receiving 51000
sending or is sending Service Description. 52000
intermittently. 53000
54000
Remedy: Clear warning.
55000
If the problem persists,
56000
determine if uplink is
57000
sending the current SI
58000
information table.
Disable the warning if
not using the table.
SDT timeout # Clear SDT fault cleared – – 51000
52000
53000
54000
55000
56000
57000
58000

PMT timeout # Set PMT # timed out Cause: Uplink is not Program Mapping 59000
sending or is sending Table was never 60000
intermittently. received. 61000
62000
Remedy: Clear warning.
63000
If the problem persists,
64000
determine if uplink is
65000
sending the current SI
66000
information table.
Disable the warning if 66009-66032
not using the table.

OL-31980 -01 305


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

PMT timeout # Set PMT # is lost Cause: Uplink is not No longer receiving 59000
sending or is sending Program Mapping 60000
intermittently. Table. 61000
62000
Remedy: Clear warning.
63000
If the problem persists,
64000
determine if uplink is
65000
sending the current SI
66000
information table.
Disable the warning if 66009-66032
not using the table.

PMT timeout # Clear PMT fault cleared – – 59000


60000
61000
62000
63000
64000
65000
66000
66009-66032
PAT timeout # Set PAT # timed out Cause: Uplink is not Program Association 67000
sending or is sending Table was never 68000
intermittently. received. 69000
70000
Remedy: Clear warning.
71000
If the problem persists,
72000
determine if uplink is
73000
sending the current SI
74000
information table.
Disable the warning if
not using the table.

PAT timeout # Set PAT # is lost Cause: Uplink is not No longer receiving 67000
sending or is sending Program Association 68000
intermittently. Table. 69000
70000
Remedy: Clear warning.
71000
If the problem persists,
72000
determine if uplink is
73000
sending the current SI
information table. 74000
Disable the warning if
not using the table.

306 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

PAT timeout # Clear PAT fault cleared – – 67000


68000
69000
70000
71000
72000
73000
74000

NIT timeout # Set NIT timed out Cause: Uplink is not Network Information 75000
sending or is sending Table was never
intermittently. received.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
NIT timeout # Set NIT is lost Cause: Uplink is not No longer receiving 75000
sending or is sending Network Information
intermittently. Table.

Remedy: Clear warning.


If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

NIT timeout # Clear NIT fault cleared – – 75000

CAT timeout # Set CAT timed out Cause: Uplink is not Conditional Access 76000
sending or is sending Table was never
intermittently. received.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

OL-31980 -01 307


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

CAT timeout # Set CAT is lost Cause: Uplink is not No longer receiving 76000
sending or is sending Conditional Access
intermittently. Table.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

CAT timeout # Clear CAT fault cleared – – 76000

DRT timeout # Set DRT # timed out Cause: Uplink is not Disaster Recovery 77000
sending or is sending Table was never
intermittently. received.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

DRT timeout # Set DRT # is lost Cause: Uplink is not No longer receiving 77000
sending or is sending Disaster Recovery
intermittently. Table.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

DRT timeout # Clear DRT fault cleared – – 77000

MCT Timeout # Set MCT # timed out Cause: Uplink is not Inband Control Table 77100
sending or is sending was never received.
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

308 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

MCT Timeout # Set MCT # is lost Cause: Uplink is not No longer receiving 77100
sending or is sending Inband Control Table.
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

MCT Timeout # Clear MCT fault – – 77100


cleared

ECT Timeout # Set ECT # timed out Cause: Uplink is not Event Control Table 77200
sending or is sending was never received.
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
ECT Timeout # Set ECT # is lost Cause: Uplink is not No longer receiving 77200
sending or is sending Event Control Table.
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.

ECT Timeout # Clear ECT fault cleared – – 77200

Memory Usage Set Excessive Cause: Possible software SW exceeding 78000


Host (stack/partition) issue. allowable memory
memory usage usage.
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.

Memory Usage Clear Normal – – 78000


Host (stack/partition)
memory usage

OL-31980 -01 309


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

Memory Usage Set Excessive Cause: Possible software Software exceeding 79000
Secondary (stack/partition) issue. allowable memory
memory usage usage.
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.

Memory Usage Clear Normal – – 79000


Secondary (stack/partition)
memory usage

FPGA Code Set FPGA newer Cause: FPGA version is FPGA version is 80000
Version than SW, incompatible with the incompatible with
Supported=AAA, software. currently operating
Running=BBB software. You may
Remedy: Select alternate
encounter operational
FPGA, software
difficulties
versions, reset unit,
notify Cisco customer
support if problem
persists.

FPGA Code Clear FPGA code ver – – 80000


Version OK

Ethernet Port Set Link is down Cause: No ethernet cable Ethernet MAC PHY 81000
<n> connected, faulty device is attempting to 82000
cabling, multiple devices reconnect to external 83000
sharing MAC address devices.
on same IP segment, or
possible HW issue.
Remedy: Check cabling,
check MAC addresses,
clear warnings, reset the
unit, and notify Cisco
customer support if the
problem persists.

Ethernet PHY n Clear Connection OK – – 81000


82000
83000

FW: Resource Set Memory or List Cause: Possible software Software exceeding 86000
Use Host Near Full issue. allowable usage of
internal constructs.
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.

310 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

FW: Resource Clear Normal Level – – 86000


Use Host

FW: Resource Set Memory or List Cause: Possible software Software exceeding 87000
Use Second Near Full issue. allowable usage of
internal constructs.
Remedy: Clear
warnings, reset the unit,
and notify Cisco
customer support if the
problem persists.

FW: Resource Clear Normal Level – – 87000


Use Second

Backup Failure Set FTP Failed Cause: FTP settings or FTP failed to connect 89000
Reason the server may not be to server or transfer
configured correctly. file.
Remedy: Verify the FTP
server configuration and
permissions. Verify that
FTP settings on the unit.
Verify that the server is
reachable from the client
(such as configuring
firewalls or network
settings). Retry the
Backup operation.
Backup Failure Set Internal Error Cause: Possible software Backup ran out of 89000
Reason issue. memory or other
internal error.
Remedy: Clear
warnings, reset the unit,
notify Cisco customer
support if problem
persists.

OL-31980 -01 311


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

Restore Failure Set FTP Failed Cause: FTP settings or FTP failed to connect 89100
Reason the server may not be to server or transfer
configured correctly. file.
Remedy: Verify the FTP
server configuration and
permissions. Verify that
FTP settings on the unit.
Verify that the server is
reachable from the client
(such as configuring
firewalls or network
settings). Retry the
Import operation.

Restore Failure Set Not Accepted Cause: Import file is Import file was 89100
Reason either for a different rejected and import
product or the structure did not occur.
was not compatible with
this unit.
Remedy: Verify that the
correct import file is
being used and was
created by this product.
Verify that the file
structure has not been
corrupted. If the
problem persists, notify
Cisco customer support.

Restore Failure Set Bad Content Cause: Import file may Item in import file is 89100
Reason be corrupted, or from a not valid for this
different version of software and import
application software. did not occur.
Remedy: Verify that the
correct import file is
being used and was
created by this product.
Verify that the file
structure has not been
corrupted. If the
problem persists, notify
Cisco customer support.

312 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

Hardware Set Non-matching Cause: Non-matching D9859 App running 94000


Platform HW Platform. App was loaded on D9854/58/24
APP: <D9859 | through either CDT platform or vice versa.
D9854/58/24>, download or FLASH
HW: <TMB2 | programming.
HDR/TMB/HDR
Remedy: Replace the
2> non-matching App and
then reboot the IRD.

Hardware Clear Matching – – 94000


Platform Hardware
Platform
detected.

Xcode Video Buf Set PE(s): x;y;z Cause: Video buffer Transcoder board 94004
Oflw overflow reported when FPGA reports buffer
the transcoding chip overflow on video PID
outputs more data that path.
the path is capable of
handling. The limitation
is a combined bit rate of
all transcoding paths
and all delayed paths,
and it is when this
combined bit rate is
above 203.04Mbps.
Remedy: Verify that the
configured overall bit
rate for 8 transcoders
does not exceed the
FPGA path limitation.

Xcode Video Buf Clear Fault cleared – – 94004


Oflw

Xcode Delay Buf Set PE(s): x;y;z Cause: Delay path buffer Transcoder board 94006
Oflw overflow reported when FPGA reports buffer
the transcoding chip overflow on delayed
outputs more data than PID path.
the path is capable of
handling.
Remedy: Verify that the
configured overall bit
rate for 8 transcoders
does not exceed the
FPGA path limitation.

Xcode Delay Buf Clear Fault cleared – – 94006


Oflw

OL-31980 -01 313


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

Xcode Delay Pkt Set PE(s): x;y;z Cause: Possible Transcoder board 94007
Drop misconfiguration of FPGA reports packet
delay value. The packet dropped on delayed
delay is caused by PID path.
arriving too early and it
cannot be held in the
buffer, or it arrived too
late on the delay path.
This is a software issue.

Xcode Delay Pkt Clear Fault cleared – – 94007


Drop

Transcoder Set Unsupported Cause: Input stream Video format of one of 94009
Input Video Format configuration is the channels is not
incorrect. supported by this
decoder.
Remedy: Request a
compatible stream
format from your uplink
provider.
Transcoder Set Unsupported Cause: Input stream Video format of one of 94009
Input Aspect Ratio configuration is the channels is not
incorrect. supported by this
decoder.
Remedy: Request a
compatible stream
format from your uplink
provider.
Transcoder Set Unsupported Cause: Input stream Video format of one of 94009
Input Video Profile or configuration is the channels is not
level incorrect. supported by this
decoder.
Remedy: Request a
compatible stream
format from your uplink
provider.

Transcoder Set Input Underflow Cause: Possible Internal transcoder 94009


Input transcoder firmware buffer overflow or
error. underflow. Errors will
be seen in the
Remedy: If problem
transcoded output.
persists, contact Cisco
customer support.

314 OL-31980-01
Warning Message Message Cause/Remedy Description ID
Type

Transcoder Set Input Overflow Cause: Possible Internal transcoder 94009


Input transcoder firmware buffer overflow or
error. underflow. Errors will
be seen in the
Remedy: If problem
transcoded output.
persists, contact Cisco
customer support.

Transcoder Set Output Cause: Possible Internal transcoder 94009


Input Underflow transcoder firmware buffer overflow or
error. underflow. Errors will
be seen in the
Remedy: If problem
persists, contact Cisco transcoded output.
customer support.

Transcoder Set Output Overflow Cause: Possible Internal transcoder 94009


Input transcoder firmware buffer overflow or
error. underflow. Errors will
be seen in the
Remedy: If problem
transcoded output.
persists, contact Cisco
customer support.

Transcoder Clear problems cleared – Transcoding is 94009


Input working properly.

Transcoder Set Low Intra and Cause: Possible Transcoded video 94012
Quality Inter scores transcoder firmware quality is degraded
error. and artifacts may be
seen in the transcoded
Remedy: If problem
video.
persists, contact Cisco
customer support.

Transcoder Set Throttling fault Cause: Possible Transcoded video 94012


Quality transcoder firmware quality is degraded
error. and artifacts may be
seen in the transcoded
Remedy: If problem
video.
persists, contact Cisco
customer support.

Transcoder Clear Quality Restored – – 94012


Quality

OL-31980 -01 315


Chapter 6 Service and Maintenance

Warning Message Message Cause/Remedy Description ID


Type

XCode Config Set Configuration Cause: Configuration or Transcoder is 94013


Mismatch Mismatch Fault software issue. Also seen generating video in a
temporarily on channel format that does not
changes or changes in match the user's
the video source format. selection.
Remedy: If problem
persists, contact Cisco
customer support.

XCode Config Clear Mismatch – – 94013


Mismatch Resolved

316 OL-31980-01
Power Supply Replacement

Power Supply Replacement


There are no user-serviceable parts in the D9859 transcoder power supply. If the
power supply requires replacement, contact your service provider or Cisco for
information on how to return the unit for repair.

OL-31980 -01 317


7 Chapter 7
Customer Information
If You Have Questions
If you have technical questions, call Cisco Services for assistance.
Follow the menu options to speak with a service engineer.
Access your company's extranet site to view or order additional
technical publications. For accessing instructions, contact the
representative who handles your account. Check your extranet site
often as the information is updated frequently.

OL-31980 -01 319


A
Appendix A
Appx auto letter

Technical Specifications
Introduction
This appendix contains the technical specifications for the D9859
Advanced Receiver Transcoder.
Note: The technical specifications are subject to change without prior
notice.

In This Appendix
 L-Band Input and Process ing ..........................................................322
 Video I nputs/Outputs and Processing ...........................................326
 Transport Stream Outputs...............................................................331
 Control, Ma nagement and Data Interfaces ....................................333
 Power and General Specif ications ...................................................335

OL-31980 -01 321


Appendix A
Technical Specifications

L-Band Input and Processing


General
Parameter Specification

System MPEG-2/DVB Compatible


EN 300 421, EN 300 468

Demodulation DVB-S QPSK, DVB-S2 QPSK and 8PSK

Number of RF Inputs 4 (only one active at a time)

LNB LO Stability
DVB-S and DVB-S2

Symbol Rate Stability

1 to 4.99 MSymbols/s ≤ ± 125 kHz

5.0 to 9.99 MSymbols/s ≤ ± 1.0 MHz

10.0 to 45 MSymbols/s ≤ ± 3.0 MHz

Parameter Specification

LNB Phase Noise -35 dBc/Hz at dF = 100 Hz


Requirement
-53 dBc/Hz at dF = 1 kHz
-76 dBc/Hz at dF = 10 kHz
-96 dBc/Hz at dF = 100 kHz
-106 dBc/Hz at dF = 1 MHz

-117 dBc/Hz at dF = 10 MHz

322 OL-31980-01
L-Band Input and Processing

LNB Power and Control


Parameter Specification

Voltage 13 V Vertical/circular right,


(RF1 only, RF2 to RF4 do not 18 V Horizontal/circular left
have LNB supply)
Off
Current 400 mA maximum

LNB Alarms:
No load - 6 mA
Overload - 360 mA minimum

DVB-S/DVB-S2
DVB-S/DVB-S2 Satellite Receiver

Parameter Specification

L-Band Input

Number of Inputs 4 (one active at a time)

Input Connector Type F-type, female, 75 ohms

Input Impedance 75 ohms

Return Loss > 10 dB

Isolation Between Inputs > 40 dB


L-band Frequency 950 to 2150 MHz

Tuning Step Size 1 MHz

Receive Spectrum Sense Normal and Inverted

L-Band Power

Input Power Level per -25 to -65 dBm (full transponder power)
Carrier

DVB-S Modulation (EN 300 421)

Modulation QPSK

Convolutional FEC Rates 1/2, 2/3, 3/4, 5/6, 7/8

Symbol Rate Range 1.0 to 45 MSymbols/s

OL-31980 -01 323


Appendix A
Technical Specifications

Parameter Specification

Eb/No (C/N) Ratio See DVB-S2 Satellite Receiver Input, DVB-S


Eb/No (C/N) Ratio Table

DVB-S2 Modulation (EN 302 307)

Modulation QPSK, 8PSK

Pilots On/Off Pilots On

QPSK LDPC FEC Rates 1/2, 3/5, 2/3, 3/4, 4/5, 5/6, 8/9, 9/10

8PSK LDPC FEC Rates 3/5, 2/3, 3/4, 5/6, 8/9, 9/10

LDPC FEC Frame Length Normal

Symbol Rate Range 1 to 30 Ms/s

Maximum Channel Bit Rate 90 Mb/s

Maximum User Bit Rate 78.55 Mb/s

DVB-S Eb/No (C/N) Ratio

Convolutional FEC Rate Eb/No Ratio (dB) in C/N at DVB Threshold


Linear Channel and IF (BW = Symbol Rate)
Loop configuration

1/2 4.5 4.1

2/3 5.0 5.9

3/4 5.5 6.9

5/6 6.0 7.9

7/8 6.4 8.5

C/N = Eb/No + 10 log (2 x FEC X 188/204)


The D9859 transcoder displays the C/N Ratio.

DVB-S2 Error Rate Performance Es/No (C/N) Ratio

Mode Simulated Es/No (dB) for Typical Performance (dB) in


FEC Frame length = 64,800 Linear Channel and IF Loop
configuration

QPSK 1/2 1.00 1.2

QPSK 3/5 2.23 2.4

QPSK 2/3 3.10 3.2

QPSK 3/4 4.03 4.2

324 OL-31980-01
L-Band Input and Processing

Mode Simulated Es/No (dB) for Typical Performance (dB) in


FEC Frame length = 64,800 Linear Channel and IF Loop
configuration

QPSK 4/5 4.68 4.8

QPSK 5/6 5.18 5.3

QPSK 8/9 6.20 6.4

QPSK 9/10 6.42 6.6

8PSK 3/5 5.50 5.8

8PSK 2/3 6.62 6.8

8PSK 3/4 7.91 8.1

8PSK 5/6 9.35 9.6

8PSK 8/9 10.69 10.9

8PSK 9/10 10.98 11.3

OL-31980 -01 325


Appendix A
Technical Specifications

Video Inputs/Outputs and Processing


General
Parameter Specification

System MPEG-2/DVB Compatible


EN 300 421, EN 300 468

Video Inputs
Item Specification

Transcoder Channel Inputs

HD Video Input

Number of Channels 1

Compression Format MPEG-2 and MPEG-4 part 10


V Resolutions 1080, 720

Horizontal Video Resolutions 1080i: 1920, 1440


720p: 1280, 960

Bit Rate 3 Mb/s to 20 Mb/s Main Profile


3 Mb/s to 25 Mb/s High Profile

Connector BNC, 75 ohms

Video Outputs
Item Specification

Transcoder Channel Outputs

HD Video Output

Number of Channels 1

Compression Format MPEG-2

Vertical Resolutions Same as input.

Horizontal Resolutions 1080i: 1920, 1440


720p: 1280, 960

326 OL-31980-01
Video Inputs/Outputs and Processing

Item Specification

Bit Rate 10 to 25 Mb/s

Analog SD Video Output

Item Test Signal Specification CVBS1 Specification CVBS2


Number of One SD source One SD source program
Channels program

Video MPEG-2 4:2:0 MPEG-2 4:2:0


Decompression

Output 75 Ω 75 Ω
Impedance

525 Line
Bar level NTC-7 comp 700 mV ± 7 mV (± 1%) 700 mV ± 35 mV (± 5%)

Line Time VITS17 ≤ 1% ≤ 1%


Distortion

Bar Tilt NTC-7 comp < 0.5% < 0.5%

Sync Level NTC-7 comp 40 IRE ± 0.5 IRE 40 IRE ± 2.0 IRE

DC Offset NTC-7 comp ± 100 mV ± 100 mV

Chrominance- NTC-7 comp 100 ± 5% 100 ± 5%


to-Luminance
Gain Inequality

Chrominance- NTC-7 comp < 20 ns < 20 ns


to-Luminance
Phase Inequality

K factor K 2T NTC-7 comp < 1% < 1%


Jitter < 5 ns < 5 ns

Frequency FCC multi-burst 0.5 MHz, 0 dB 0.5 MHz, 0 dB


Response
1.25 MHz, 0 dB ± 0.2 dB 1.25 MHz, 0 dB ± 0.2 dB
2 MHz, 0 dB ± 0.2 dB 2 MHz, 0 dB ± 0.2 dB
3 MHz, 0 dB ± 0.3 dB 3 MHz, 0 dB ± 0.3 dB
3.58 MHz, 0 dB ± 0.3 dB 3.58 MHz, 0 dB ± 0.3 dB
4.1 MHz, 0 dB ± 0.3 dB 4.1 MHz, 0 dB ± 0.3 dB

Differential Gain NTC-7 comp < 3.0% < 3.0%

OL-31980 -01 327


Appendix A
Technical Specifications

Item Test Signal Specification CVBS1 Specification CVBS2

Differential NTC-7 comp < 3° < 3°


Phase

Luminance < 5% < 5%


Non-linearity

Line Time NTC-7 comp ≤ 1% ≤ 1%


Distortion

Weighted Signal 50% Grey Field ≤ -70 dB rms ≤ -70 dB rms


Video-to-Noise

Weighted Signal Luminanace ≤ -55 dB rms ≤ -55 dB rms


Video-to-Noise Ramp

Return Loss DC to 10 MHz, > 30 dB DC to 10 MHz, > 30 dB

625 Line

Bar level VITS17 700 mV ± 7 mV (± 1%) 700 mV ± 35 mV (± 5%)

Line Time VITS17 ≤ 1% ≤ 1%


Distortion
Bar Tilt VITS17 < 0.5% < 0.5%

Sync Level VITS17 300 mV ± 3 mV 300 mV ± 15 mV

DC Offset VITS17 ± 100 mV ± 100 mV

Chrominance- Colour Bars 100 ± 5% 100 ± 5%


to-Luminance
Gain Inequality

Chrominance- Colour Bars < 20 ns < 20 ns


to-Luminance
Phase Inequality

K factor K 2T VITS17 < 1% < 1%

Jitter < 5 ns < 5 ns


Frequency VITS18 0.5 MHz, 0 dB 0.5 MHz, 0 dB
Response
1 MHz, 0 dB ± 0.2 dB 1 MHz, 0 dB ± 0.2 dB
2 MHz, 0 dB ± 0.3 dB 2 MHz, 0 dB ± 0.2 dB

4 MHz, 0 dB ± 0.3 dB 4 MHz, 0 dB ± 0.3 dB


4.8 MHz, +0 dB, -0.5 dB 4.8 MHz, +0 dB, -0.5 dB

Differential Gain VITS330 < 3.0% < 3.0%

Differential VITS330 < 3° < 3°


Phase

328 OL-31980-01
Video Inputs/Outputs and Processing

Item Test Signal Specification CVBS1 Specification CVBS2

Luminance VITS17 < 5% < 5%


Non-linearity

Weighted Signal 50% Grey Field ≤ -70 dB rms ≤ -70 dB rms


Video-to-Noise

Weighted Signal Luminanace ≤ -55 dB rms ≤ -55 dB rms


Video-to-Noise Ramp

Return Loss DC to 10 MHz, > 30 dB DC to 10 MHz, > 30 dB

Audio Inputs/Outputs
Analog SD Video Output, CVBS1 and CVBS2 for monitoring

Item Specification

Number of Channels One down-converted source HD program

Video Decompression Type MPEG-2 4:2:0

Output Level 1.0 Vpp ± 5%

Output Impedance 75 ohms

Analog Audio Inputs

Item Specification
Number of Channels 2

Audio Decompression MPEG or Dolby Digital and Dolby Digital Plus

Analog Audio Outputs

Item Specification

Number of Channels 2 stereo pairs or 4 mono channels

Audio Decompression MPEG or Dolby Digital

OL-31980 -01 329


Appendix A
Technical Specifications

VBI Data Input/Output


Item Specification

Transmission Format EIA-708 and EIA-608

330 OL-31980-01
Transport Stream Outputs

Transport Stream Outputs


ASI Output
Item Specification

Number of outputs 3 (mirrored)

Type of connector 75 ohms BNC

Output impedance 75 ohms according to EN 50083-9

Data amplitude 800 mV peak-peak ± 10% according to EN 50083-


9
Return loss > 17 dB, 27 to 270 MHz

Transport stream data rate 1 to 120 Mbit/s

ASI transmission rate 270 MBaud ± 100 ppm

Transport stream formats According to EN 50083-9

188 bytes structure


Burst or packet format

MPEGoIP Output
Item Specification

Number of outputs 1

Type of connector RJ-45, 10/100/1000 BASE-T

Output modes UDP RAW, RTP

IP Addressing Multicast, Unicast

TS Streaming MPTS

TS Bit Rate 1 to 120 Mbps


MPEGoIP bit rate Up to 206 Mbps

MPE Output
Item Specification
Number of Outputs 1

OL-31980 -01 331


Appendix A
Technical Specifications

Item Specification

Type of connector RJ-45, 10/100/1000 BASE-T

Output modes IPv4 datagrams

IP Addressing Multicast, Unicast

TS Input up to 5 PIDs

Bit Rate up to 10 Mbps (for 1500 byte packets)

332 OL-31980-01
Control, Management and Data Interfaces

Control, Management and Data Interfaces


Ethernet Management Interface
Item Specification

Number of connectors 1

Type of connector Eight-pin RJ-45

Ethernet type 10/100/1000BASE-T

Required setup IP address, default gateway and subnet mask

Ethernet Data Interface


Item Specification
Number of connectors 1

Type of connector Eight-pin RJ-45


Ethernet type 10/100/1000BASE-T

Required setup IP address, default gateway and subnet mask

RS-232 Data Interface


Item Specification
Connector type 9-pin sub-D female

Data rates RS-232 asynchronous data at selectable rates up


to 38.4 kb/s: 300, 1200, 2400, 4800, 9600, 19,200,
38,400 b/s

Alarm Interface
Item Specification

Number of outputs 3, each having one set of contacts closed and one
set open during normal operation. Alarms are
signaled by reversing the polarity of the two
contact sets.

OL-31980 -01 333


Appendix A
Technical Specifications

Item Specification

Type of connector Terminal block

Max. voltage ≤ 30 V AC, ≤ 30 V DC

Max. current ≤1A

Contact Closure Interface


Item Specification

Connector type 9-pin sub-D female

Minimum duration of event 250 ms, 1 frame period, e.g., for 1080i/25 Hz, 40
guaranteed to be detected ms for DPI applications

Max. on generator impedance 100 ohms

Min. off generator impedance 100 kilohms

334 OL-31980-01
Power and General Specifications

Power and General Specifications


General
Item Specification

LCD 2 lines of 40 characters, backlit LCD.

Keypad Arrow keys, 0 to 9, SELECT, MENU, INFO,


ADV, MAP, APPLY and NAV keys.
LEDs Green LED for Signal status. Red LED for Alarm
indication.

Power
AC Power Connector

Item Specification

Type of connector IEC 320 style C14 appliance receptable

AC input 100 to 240 V AC, 50/60 Hz

Power 125 W max.

Power Quality ANSI/IEEE Std C62.41.1-2002

Power
To operate the transcoder, you must connect it to an AC power source.
WARNING:
Make sure that at least one end of the power cable(s) remains easily accessible for
unplugging, if you need to switch off the unit. For example: Ensure that the socket
outlet is installed near the product.

WARNING:
To avoid electrical shock, connect the three-prong plug on this product to an earth-
grounded three-pin socket outlet only.

OL-31980 -01 335


Appendix A
Technical Specifications

Mechanical
Item Specification

Height 1 RU (1.75 in.) (4.4 cm)

Width 19.0 in. (48.3 cm)

Depth 20.5 in. (52.1 cm)

Weight 16 lb (7.2 kg)

Environment
Item Specification

Storage

General The product is within the original packaging.

Humidity 5 – 95% non-condensing

Temperature -20 – +70°C (-4 to 158°F)

Operation

Humidity (non-condensing) 95% humidity is valid up to 40°C


91% humidity is valid up to 45°C
70% humidity is valid up to 50°C

Temperature 0°C – +50°C (32°F to 122°F)

Altitude

Operating 10,000 ft. (3048 m) max.

Non-operating 30,000 ft. (9144 m ) max.

336 OL-31980-01
B
Appendix B
Appx auto letter

Default Settings and Lock


Levels
Introduction
This appendix lists the factory default settings and the lock levels for
the D9859 transcoder.

In This Appendix
 Factory Default Settings and Lock Levels ......................................338
 DPM Default Settings for Different Output Modes .......................351

OL-31980 -01 337


Appendix B
Default Settings and Lock Levels

Factory Default Settings and Lock Levels


The D9859 Advanced Receiver Transcoder is factory configured with default settings
unless you have requested a custom factory configuration.
The following table lists the lock levels available for protecting your transcoder and
its settings against unauthorized use or modification:

Level Description

0 All settings are unlocked (transcoder lockout disabled)

1 All settings are unlocked except Factory Reset,


Password options and transcoder parameters.

2 All settings are unlocked except RF and ASI Input


Tuning parameters.
3 All settings locked (access via password only), except IP
address and RF power.

4 All settings locked (can be changed via PNC uplink


signal only)

If a change made to the current Lock Level setting is not saved, the previously saved setting
is restored.
Note: The user cannot select NONE as a Lock Level.

Administration
Parameter Default Lock Level

Lock Level 0 3

Password 1234 3

Old Pwd, New Pwd, Confirm N/A 0


Pwd

Factory Reset N/A 0

Clear FWD Tables N/A 0


KB Lock Disable 2

KB Lock Timeout 60 2

LCD Contrast 30 2

DL Mode Always 2

Type None N/A

Bank App 5514 N/A

338 OL-31980-01
Factory Default Settings and Lock Levels

Parameter Default Lock Level

Date Format YYY_MM_DD 2

Time Format 24 Hr 2

GMT Off +05.30 2

Reboot N/A 2

ASI Input
Parameter Default Lock Level

ASI Active No 1

Tune Mode Basic 1

CA Ctl STD 1

Select UserCfg 1

RF Input
Parameter Default Lock Level

RFx Active RF1 is Act, RF2 to RF4 is No 1

Tune Mode Basic 1

CA Ctl Std 1

Select UserCfg 1
LO1 (GHz) 5.15 1

LO2 (GHz) 0.0 1

Crossover (GHz) 0.0 1

OrbPos 0.0 1

E/W NA 1

Pol H (horizontal) 1

Freq (GHz) 3.449 1

Sym Rate 28.3465 MS/s 1

FEC Auto 1

LNB Type C-Band 1


Modulation DVB-S 1

OL-31980 -01 339


Appendix B
Default Settings and Lock Levels

Parameter Default Lock Level

Roll-off .35 1

InputIQ Auto 1

NetID 1 1

LNB Power Off 3

22kHz Off 1

Tune Mode
Parameter Default Lock Level

Service List Mode Rigorous 1

Frequency Tuning NIT 1

BAT No 1

NIT Yes 1

SDT Yes 1
PAT Yes 1

Disaster Recovery
Global

Parameter Default Lock Level

D/R Enable Yes 1

Signal Loss Timer 120 1

Signal Lock Timer 30 1

Verify Timer 60 1

Backup Channel
The default is 0 and the lock level is 1.

Transport

Parameter Default Lock Level

Active No 1

340 OL-31980-01
Factory Default Settings and Lock Levels

Parameter Default Lock Level

Input RF1 1

NetId 1 1

Freq (GHz) 3.4 1

SymRate 2 1

FEC Auto 1

Modulation DVB-S 1

Rolloff 0.35 1

IP
Note: A factory reset does not change the IP settings.

Parameter Default Lock Level


Port ID 1 3

V4/V6 IPv4 N/A

IP Address 192.131.244.6 3

Mask 24 3
Gateway 255.255.255.0 3

Phy Mode Auto 3

MAC Address 00:00:00:00:00:00 N/A

SNMP Read Community public 3


String

SNMP Write Community public 3


String

Password Complexity Full Complexity Checking N/A

SNTP Server 0.0.0.0 3

SNTP Enable No 3

Reset Credentials N/A 0

OL-31980 -01 341


Appendix B
Default Settings and Lock Levels

Trap Destinations
Parameter Default Lock Level

Trap IP Address 0.0.0.0 2

Trap Community String public 2

Protocols
Parameter Default Lock Level

Telnet Disable 3

SSH Disable 3

HTTP Enable 3

SNMP Disable 3

MPE Fwd All 3


Syslog Disable 3

Syslog Server 0.0.0.0 3

Port 514 3

Video
Parameter Default Lock Level

PV Format SD 2

SD Format Auto 2

Alarm Video Cutoff Disable 2

OSD Messages Enable 2

TV A/R 4:3 2

Convert None 2
WSS Mode Passthrough 2

Enable Banner Display (Web Enable 2


GUI only)

342 OL-31980-01
Factory Default Settings and Lock Levels

Audio
Parameter Default Lock Level

Stereo/Mono Stereo 2

AC3 Compression RF Mode 2

Left (dB) 0 2

Right (dB) 0 2

Select Language By PMT Order 2

Language List eng 2

PMT Source AUD1 for Audio 1 and AUD2 for 2


Audio 2

Entry eng 2

Captions
Parameter Default Lock Level

Preferred Mode Auto 2

VBI
Parameter Default Lock Level

WSS Mode Passthrough 2

WSS Stat Undefined N/A

VITS PAL Line 17, 18, 330, Disable 2


331

Subtitles
Parameter Default Lock Level
Op Mode Off 2

Select Language By Language Entry 2

Language List eng 2

OL-31980 -01 343


Appendix B
Default Settings and Lock Levels

Parameter Default Lock Level

PMT Order First 2

Entry eng 2

Imitext Position Standard 2

ForeGnd Auto 2

BackGnd Auto 2

Decode
Parameter Default Lock Level

Decoder N/A 2

Enabled Yes 2
Note: By default, all the decode services are enabled.

Cueing
Parameter Default Lock Level

Cueing Mode Trigger 4

Trigger Polarity High 4

Repeat 3 4

Tone (ms) 40 4

Silence (ms) 40 4
Seq# 1 4

State Disable 4

Tones 0 4

Mode * 4

Delay (sec) 1 4

Relay Mode Alarm 4

Cue Trigger Bit 1 4

344 OL-31980-01
Factory Default Settings and Lock Levels

TS Out - ASI
Parameter Default Lock Level

Name ASI N/A

Rate Control User 2

User Rate 68.5 Mbps 2

Output Mode No Output 2

Descramble Mode Descrambled 2

Insert Null Packet Yes 2

Auto Map Yes N/A

Auto Map Aux No N/A

TS Out - MOIP
Parameter Default Lock Level

Name MOIP N/A

Rate Control User 2

User Rate 0 2

Output Mode No Output 2

Descrambled Mode Descrambled 2

Insert Null Packet Yes 2

Auto Map Yes N/A

Auto Map Aux No N/A

MOIP Streams

Parameter Default Lock Level

User Rate 68.5 Mbps 2

Intf Mode None 2

TS/IP 7 2

PCR@IP Start No 2

MOIP UDP 2

OL-31980 -01 345


Appendix B
Default Settings and Lock Levels

Parameter Default Lock Level

Min IP/s 0 2

TOS 0 2

TTL 64 2

DestAddr 225.1.1.1 2

UDPPort 49152 2

SrcPort 0 2

Send SAP None 2

SAP Address 224.2.127.25 2

SAP Port 9875 2


SAP ID User String 2

SAP User Str Cisco Default SAP1 2

DPM - ASI/MOIP
Parameter Default Lock Level
PE PE1 N/A

Act Drop 2

StType N/A 2

OutCh 0 2

PMT 8191 2

OType UNKN 2

In N/A 2

PID 0 2

Map Mode SVC ID & PID 2

Duplic Mode Pkt Copy 2

Unref Drop 2

PSI Options Drop All 2

PSI Rate SA Std 2

Service ID Valid Ch 2

PAT Pass 2

346 OL-31980-01
Factory Default Settings and Lock Levels

Parameter Default Lock Level

CAT Pass 2

PMT Pass 2

TSDT Pass 2

NIT Pass 2

NITO Pass 2

SDT Pass 2

SDTO Pass 2

BAT Pass 2

EIT Pass 2
TDT Pass 2

RST Pass 2

TOT Pass 2

DIT Pass 2

SIT Pass 2

ECM Pass 2

EMM Pass 2

DRT Pass 2

CDT Pass 2

Transcode
Parameter Default Lock Level

PE PE1 N/A

Video Mode HD Output 0

HD HRes Full 0

SD HRes 720 0

HD/SD B/R Mode CBR 0


HD Bitrate 16 Mb/s 0

SD Bitrate 4.0 Mb/s 0

HD/SD GOP Control User GOP (MN) 0


HD/SD User GOP (MN) 15 2 0

OL-31980 -01 347


Appendix B
Default Settings and Lock Levels

Parameter Default Lock Level

HD/SD 3:2 Pulldown Disabled 0

SD Aspect Ratio 16:9 0

SD AR Conv None 0

CC Pkt1 CEA 708 0

CC Pkt2 None 0

LOI Action Black Output 2

Inband
Parameter Default Lock Level

PE PE1 N/A

Apply Inband No 0

Options
Parameter Default Lock Level

Output 1 N/A

Fixed Output No N/A

Use Inp Chan No N/A

Start 1 N/A
Step 1 N/A

Use Inp PMT No N/A

Start 1701 N/A

Step 1 N/A

Use Inp PIDs No N/A

Start 101 N/A

Step 100 N/A

Use Inp Ord Yes N/A

PCR 1 N/A

VID 1 N/A
AUD 8 N/A

348 OL-31980-01
Factory Default Settings and Lock Levels

Parameter Default Lock Level

SUBT 8 N/A

VBI 2 N/A

DPI 2 N/A

MPE 5 N/A

TTX 1 N/A

DATA 1 N/A

LSD 1 N/A

CDT 4 N/A

ETV 4 N/A

Alarm/Warning
Parameter Default Lock Level

FP Alarm Reminder Enable 2


Alarm Vid Cutoff Disable 2

Enb N/A 2

Rly N/A 2

Trp N/A 2

Noise Cutoff
Parameter Default Lock Level

Trnsprt (DVB-S/DVB-S2 Marg) Cutoff 0.0 2

Trnsprt (DVB-S/DVB-S2 Marg) Restore 0.1 2

Audio (DVB-S/DVB-S2 Marg) Cutoff 0.0 2

Audio (DVB-S/DVB-S2 Marg) Restore 0.1 2

Muting Control Enable 2

Restore Defaults N/A 2

OL-31980 -01 349


Appendix B
Default Settings and Lock Levels

Import/Export (Web GUI only)


Parameter Default Lock Level

Settings File Name file name 3

FTP Server IP Address 192.168.0.100 3

FTP Port Number 21 3

FTP User Name user 3

FTP Password USER 3

350 OL-31980-01
DPM Default Settings for Different Output Modes

DPM Default Settings for Different Output Modes


The DPM parameters are preset to default settings for each DPM Output Mode.

The default settings for particular Output modes have been preset to optimize the
output when either PID mapping or transcoding is required. If the DPM parameters
are changed to values which switch the transcoder to Full DPM Control, the
transcoder may enter a condition where conflicts in the settings may occur, which
may require manual manipulation of the DPM or output parameters to obtain the
desired output.
The fields labeled “Any” in the table below, are not used, in which case, the Output
Mode will not change if the parameter is changed. However, if you change any of
the other parameters listed in the table for the MAP or Transcoding output modes,
the Output Mode will change to Full DPM Control.

Output No Output Passthrough Service MAP MAP Svc Full DPM Transcoding
Mode Chans Only Passthrough Chans Only Control

Rate Control Any Any Any Any Any Any Any


(unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged)

User Rate Any Any Any Any Any Any Any


(unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged)

Descramble Any Any Any Any Any Any Descrambled


Mode (unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged)

Regenerate Any Any Any Any Any Any Any


(unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged)

Insert Null Any Any Any Any Any Any Any


Packet (unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged) (unchanged)

Map Mode Any (not Svc ID Svc ID Svc Id & PID Svc ID & Actual Value Svc ID & PID
used) PID
Duplic Mode Any (not PSI Remap PSI Remap Pkt Copy Pkt Copy Actual Value Pkt Copy
used)

Unref Drop Pass Drop Pass Drop Actual Value Drop

PSI Options Drop Ctl By Table Ctl By Table Ctl By Table Ctl By Table Actual Value Ctl By Table
PSI Rate Any (not SA Std SA Std SA Std SA Std Actual Value SA Std
used)
Svc ID Any (not Valid Ch Valid Ch Valid Ch Valid Ch Actual Value Valid Ch
used)

PAT Not Pass Regen Regen Regen Actual Value Regen


Displayed

OL-31980 -01 351


Appendix B
Default Settings and Lock Levels

Output No Output Passthrough Service MAP MAP Svc Full DPM Transcoding
Mode Chans Only Passthrough Chans Only Control

CAT Not If If If If Actual Value Regen


Displayed Descramble Descramble Descramble Descramble
Mode is set Mode is set Mode is set Mode is set
to to to to
Descrambled, Descrambled, Descrambled, Descramble
it is set to it is set to it is set to d, it is set to
Regen; Regen; Regen; Regen;
otherwise, it otherwise, it otherwise, it otherwise, it
is set to Pass is set to Pass is set to Pass is set to Pass

PMT Not If If Regen Regen Actual Value Regen


Displayed Descramble Descramble
Mode is set Mode is set
to to
Descrambled, Descrambled,
it is set to it is set to
Regen; Regen;
otherwise, it otherwise, it
is set to Pass is set to Pass

TSDT Not Pass Pass Pass Pass Actual Value Pass


Displayed

NIT Not Pass Regen Regen Regen Actual Value Regen


Displayed

NITO Not Pass PwRc PwRc PwRc Actual Value Drop


Displayed
SDT Not If Regen Regen Regen Actual Value Regen
Displayed Descramble
Mode is set
to
Descrambled,
it is set to
Regen;
otherwise, it
is set to Pass

SDTO Not If PwRc PwRc PwRc Actual Value Drop


Displayed Descramble
Mode is set
to
Descrambled,
it is set to
Regen;
otherwise, it
is set to Pass

352 OL-31980-01
DPM Default Settings for Different Output Modes

Output No Output Passthrough Service MAP MAP Svc Full DPM Transcoding
Mode Chans Only Passthrough Chans Only Control

BAT Not If PwRC PwRC PwRC Actual Value Drop


Displayed Descramble
Mode is set
to
Descrambled,
it is set to
PwRC;
otherwise, it
is set to Pass

EIT Not Pass Pass Pass Pass Actual Value Drop


Displayed

TDT Not Pass Pass Pass Pass Actual Value Pass


Displayed
RST Not Pass Pass Pass Pass Actual Value Pass
Displayed

TOT Not Pass Pass Pass Pass Actual Value Pass


Displayed

DIT Not Pass Pass Pass Pass Actual Value Pass


Displayed

SIT Not Pass Pass Pass Pass Actual Value Pass


Displayed

ECM Not Pass Pass Pass Pass Actual Value Drop


Displayed

EMM Not Pass Pass Pass Pass Actual Value Drop


Displayed

DRT Not Pass Pass Pass Pass Actual Value Drop


Displayed
CDT Not Pass Pass Pass Pass Actual Value Drop
Displayed
PE Action (all Drop Pass Pass Map Map Actual Value Transcode
PEs)

OL-31980 -01 353


C
Appendix C
Appx auto letter

Compliance
Introduction
This appendix contains the compliance information for the D9859
Advanced Receiver Transcoder.
Appe

In This Appendix
 Applicable Standa rds and Notices ..................................................356
 Declaration of Conform ity ...............................................................358

OL-31980 -01 355


Appendix C
Compliance

Applicable Standards and Notices


Safety
The D9859 Advanced Receiver Transcoder has been approved for safety by the
Standards Council of Canada and the OHSA (NRTL) Accredited Testing Laboratory
to the following standards:
CAN/CSA 60065-03 + Am1 +Am2 - Audio, Video and Similar Electronic Apparatus
- Safety Requirements.

UL Std No. 60065-03 (2012) - Audio, Video and Similar Electronic Apparatus - Safety
Requirements.

Also, this product is being evaluated under the IECEE CB scheme to the following
international standard:
IEC 60065:2001 (Seventh Edition) + A1:2005 + A2:2010 including the National
requirements of AR, AT, AU, BE, CA, CH, CN, CZ, ES, DE, DK, FI, FR, GB, HU, IE,
SI, IT, JP, KR, MY, NL, NO, PL, SE, SG, SI, SK, SV, US, UA and Group Differences as
posted at the following IECEE CB Website:
http://members.iecee.org/iecee/ieceem embers.nsf.

ESD
Electrostatic Discharge (ESD) results from the static electricity buildup on the human
body and other objects. This static discharge can degrade components and cause
failures.
Take the following precautions against electrostatic discharge.
Use an anti-static bench mat and a wrist strap or ankle strap designed to safely
ground ESD potentials through a resistive element.
Keep components in their anti-static packaging until installed.

Avoid touching electronic components when installing a module.

Electromagnetic Compatibility Regulatory Requirements


Ethernet cables should be of single-shielded or double-shielded type. Coaxial cables
should be of the double-braided shielded type. Where this equipment is subject to
USA FCC and/or Industry Canada rules, the following statements apply:

356 OL-31980-01
Applicable Standards and Notices

FCC Notices
This equipment has been tested and found to comply with the limits for a Class B
digital device pursuant to Part 15 of the FCC rules. These limit s are designed to
provide reasonable protection against harmful interference when operated in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy, and if not installed and used in accordance with the instructio ns
supplied in this manual may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception (which can be determined by turning the equipment off and on), the user
is encouraged to try to correct the interference by one or more of the following
measures:
1 Reorient or relocate the television receiving antenna.
2 Increase the separation between the equipment and the receiver.
3 Connect the equipment to an AC outlet on a circuit different from that to which
the receiver is connected.
4 Contact your dealer/ reseller or an experienced radio/ TV technician for help.
The user may find the booklet “Interference handbook” prepared by the Federal
Communications Commission helpful. This booklet is available from the U.S.
Government Printing Office, Washington, DC 20402, stock no. 004 -000-00450-7.
Shielded cables should be used to interconnect this device with any other/peripheral
equipment (i.e., data sources, terminals, monitors, etc.) to ensure compliance with
Class B limits. Failure to do so may result in radio or TV interference. Cables should
be of braided shield construction with metal end shells.

Industry Canada Notice


This digital apparatus does not exceed the limits for Class B radio noise emissions
from digital apparatus as set out in the radio interference regulations of the Industry
Canada.
Le present appareil numerique n’emet pas de bruites radioelect riques qui dépassant
les limites applicables aux appareils numeriques de Class B prescrites dans le
reglement sur le brouillage radioelectrique edicte par Industrie Canada.

Unauthorized Modifications
The manufacturer is not responsible for any radio or TV interference resulting from
unauthorized modifications made to this equipment. It is the responsibility of the
user to correct such interference at his own expense.

OL-31980 -01 357


Appendix C
Compliance

Declaration of Conformity

358 OL-31980-01
Declaration of Conformity

OL-31980 -01 359


Index
Channel Authorization Status • 39
A Configuring DPM General Settings • 192
About Menu • 124 Configuring MPEG over IP Streams • 201
About the Front Panel • 34 Configuring Open-collector Outputs • 29
Accessing T CP and UDP Services • 74 Configuring System Settings • 218
Adding a New User • 31 Configuring the ASI Output • 182
Administration • 338 Configuring the Disaster Recovery Settings •
Administrator User Privileges • 30 154
Alarm Interface • 333 Configuring the DPM MPEGoIP Output Details
Alarm/Warning • 349 • 203
Alarms • 260 Configuring the MPE Settings • 226
Alarms/Warnings • 129 Configuring the MPEGoIP Output • 195
Analog Audio Inputs • 329 Configuring T ranscoder Settings • 214
Analog Audio Outputs • 329 Configuring T ransport Stream Information • 182
Analog SD Video Output • 327 Connecting an External Alarm System • 27
Analog SD Video Output, CVBS1 and CVBS2 Connecting the AC Power to the D9859
for monitoring • 329 T ranscoder • 22
Applicable Standards and Notices • 356 Connecting the ASI Input • 25
Applying Inband Settings • 216 Connecting the ASI Outputs • 27
ASI Input • 62, 339 Connecting the Balanced Audio Output • 25
ASI Output • 331 Connecting the Composite Video Output • 25
ASI/MOIP • 100 Connecting the Cue T one Interface • 29
Aspect Ratio Conversions • 79 Connecting the Cue T one/Cue T rigger Interface
Assigning a Program Channel to a PE (Program • 28
Entry) • 15 Connecting the Cue T rigger Interface • 29
Assigning Program to the Program Entry • 41 Connecting the Ethernet Management Interface •
Audio • 81, 343 26
Audio Inputs/Outputs • 329 Connecting the Input/Output Signals • 25
Connecting the IP T S Output • 26
B Connecting the RF Inputs • 25
Backup Channel • 123 Connecting the RS-232 Data Interface • 28
Backup Channel Status • 54 Connecting the T ranscoder to Other Equipment •
Backup T ransport • 123 11
Backup T ransport Status • 54 Connecting the Video Outputs • 25
Connector for the Video Output • 25
C Contact Closure Interface • 334
Captions • 83, 343 Control, Management and Data Interfaces • 333
Changing a Password (allowed by all Users) • 32 Cooling • 21
Changing a Username • 32 Cueing • 89, 344
Changing the Lock Level Password • 250 Customer Information • 319
Changing the Relay Mode for Alarm Monitoring
• 27

OL-31980 -01 361


Index

Introduction • 1
D
IP • 69, 341
D9859 Advanced Receiver T ranscoder • 2
D9859 Menus • 138
K
D9859 Summary Overview • 135 Key Features • 2
D9859 T ranscoder Alarm Messages • 260 Keypad • 34
D9859 Web GUI Environment • 140
Declaration of Conformity • 358
L
Decode • 87, 344 L-Band Input and Processing • 322
Deleting a Program from the Program Entry • 42 LCD • 34
Deleting a User • 31 LCD Panel • 39
Diagnostics Menu • 129 LCD Symbol • 40
Digital Program Distribution • 2 Licenses • 125
Disaster Recovery • 6, 340 Link Status • 52
Downloading a Software License • 258 LNB LO Stability • 322
Downloading the Software Application • 258 LNB Power and Control • 323
DPM - ASI/MOIP • 346 Locking/Unlocking the Front Panel • 38
DPM - Global • 100 Logging On to the Web GUI • 134
DPM Default Settings for Different Output Logs • 129
Modes • 351
DVB-ASI Outputs • 4 M
DVB-S Eb/No (C/N) Ratio • 324 Main Menu • 43
DVB-S/DVB- S2 • 323 Main Structure • 39
DVB-S2 Error Rate Performance Es/No (C/N) Main Versions • 126
Ratio • 324 Maintenance of EMC Compliance • 10
Mechanical • 336
E
MOIP • 94
Environment • 336 MOIP Streams • 97, 345
Ethernet Data Interface • 333 Mounting the D9859 T ranscoder to a Rack • 21
Ethernet Management Interface • 333 MPE Output • 5, 331
MPEGoIP Output • 4, 331
F
N
Factory Default Settings and Lock Levels • 338
Front Panel LEDs • 34 Navigation/Selection Keypad • 35
Front Panel Operation • 33 Noise Cutoff • 349
G O
General • 124, 322, 326, 335 Options • 348
Global • 122
Global Status • 52, 54 P
Grounding • 21 PID Map Menu • 104
Power • 335
H
Power and General Specifications • 335
Health Monitor • 132 Power Connection • 20
Power On • 131
I Power Supply Replacement • 317
Import/Export (Web GUI only) • 350 Printing the List of Users • 32
Inband • 112, 348 Program PIDs • 50
Installation • 19 Program Status • 50
Installing the D9859 T ranscoder • 21 Protocol Control Settings • 221

362 OL-31980-01
Index

Protocols • 73, 342 Alarm/Warning • 117


PSI - Channels • 130 DR • 121
PSI - Frequency Plan • 130 IP • 68
PSI - T ables • 131 Noise Cutoffs • 119
PSI T able Settings • 105 Software Update • 3
Starting a T elnet/SSH Session • 30
Q Startup Screen • 39
Quick Setup - Read Me First! • 9 Status Menu • 44
Quick Setup Inst ructions for RF Acquisition • 13 General • 45
Services • 46
R T S Input • 47
Rack Mounted • 21 T S Output • 52
Re-Acquire • 68 Status Menu - DR • 53
Rear Connector Panel • 23 Status Menu - IP • 52
Redundancy • 75 Stream Status • 53
Redundancy Status • 52 Structure • 44
Resetting the Login Credentials • 32 Subtitles • 85, 343
RF Input • 339 Synchronizing Output Services • 108
RF1, RF2, RF3, RF4 (RFx) Input • 63 Synchronizing the Inputs • 190
RS-232 Data Connector Pin Allocation • 28 System Logs • 222
RS-232 Data Interface • 333
T
S T o Add a Static Multicast Filtering • 227
Service and Maintenance • 259 T o Add a T rap Destination • 228
Setting Admin User Privileges via a T elnet/SSH T o Add a User Account • 247
Connection • 30 T o Change the User Login Passwords • 245
Setting the DPM General Settings • 207 T o Delete a User Account • 248
Setting the DPM Mode • 17 T o Set Up Warnings • 233
Setting the Maximum and Minimum T ransport T ranscode • 110, 347
Packets • 201 T ranscoder Hardware Versions • 128
Setting up Audio and Video Information • 168 T ranscoder Software Versions • 128
Setting up Default Settings for the T ranscoder • T ransport Stream Outputs • 4, 331
213 T rap Destinations • 342
Setting Up Digital Program Mapping (DPM) • T raps • 72
106 T S Out - ASI • 91, 345
Setting up for Network Connection • 12 T S Out - DPM • 99
Setting up Import/Export FT P Information • 243 T S Out - MOIP • 345
Setting up Input Information • 141 T S Out - Options • 113
Setting Up the ASI Auto Synchronization T S Out - T ranscode • 109
Options • 185 T S Output Options • 113
Setting up the ASI Output • 16 T une Mode • 67, 340
Setting Up the MPEG over IP Auto T ypical set up for Digital Program Mapping
Synchronization Options • 199 (DPM) • 210
Setting up the RF Input • 141
V
Setting up the Video Parameters • 168
Setting Up T ranscoding • 112 VBI • 84, 343
Setup Menu • 56 VBI Data Input/Output • 330
Verifying Software and FPGA Integrity Hash
Digest • 238
Versions Menu • 126

OL-31980 -01 363


Index

Video • 77, 342


Video Inputs • 326
Video Inputs/Outputs and Processing • 326
Video Outputs • 326
Viewing Contact Information • 252
Viewing Stream Details • 203
Viewing Support Information • 252
Viewing the ASI Output Status • 187
Viewing the ASI Output T ransport Status • 194
Viewing the Disaster Recovery Status • 157
Viewing the Link Status • 223
Viewing the MPEG Output T ransport Status •
210
Viewing the MPEG over IP Output Status • 203
Viewing the System Identification • 218
Viewing T ranscoder Version Information • 239
VIT C • 84
VIT S • 84
W
Warnings • 299
Web GUI Setup and Monitoring • 133
Window Buttons • 140
WSS • 84

364 OL-31980-01
Americas Headquarters
Cisco Systems, Inc. http://www.cisco.com
170 West Tasman Drive Tel: 408 526-4000
San Jose, CA 95134-1706 800 553-6387
USA Fax: 408 527-0883
This document includes various trademarks of Cisco Systems, Inc. Please see the Notices
section of this document for a list of the Cisco Systems, Inc. trademarks used in this
document.
Product and service availability are subject to change without notice.
© 2014 Cisco and/or its affiliates. All rights reserved.
April 2014 Part Number OL-31980-01

You might also like