0% found this document useful (0 votes)
4 views

elec

The project focuses on developing an Arduino-based transformer protection system that monitors current levels and isolates the transformer in case of faults to prevent overheating and damage. It utilizes a relay, contractor, LCD for current readings, and a buzzer for alarms, all controlled by a microcontroller. The conclusion emphasizes that such protective measures enhance reliability, reduce outages, and facilitate quicker power restoration through remote indication via SMS.

Uploaded by

vivek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
4 views

elec

The project focuses on developing an Arduino-based transformer protection system that monitors current levels and isolates the transformer in case of faults to prevent overheating and damage. It utilizes a relay, contractor, LCD for current readings, and a buzzer for alarms, all controlled by a microcontroller. The conclusion emphasizes that such protective measures enhance reliability, reduce outages, and facilitate quicker power restoration through remote indication via SMS.

Uploaded by

vivek
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

GOVERNMENT ENGINEERING COLLEGE, DAHOD

ELECTRICAL ENGINEERING DEPARTMENT

PROJECT TITLE : PROTECTION OF TRANSFORMER


ABSTRACT MODAL PIC
Our aim is to protect the whole Transformer from major fault. The main
intension of this project is to describe Arduino based system that can be used
in a transformer protection. The system checks the operating parameters of
the transformer i.e. current and reports the quantity that is flowing through the
transformer. The system is designed such that it is able to detect current
above the normal operating level and isolate the transofrmer from faulty line or
parts. This isolation process is to ensure that the transformer is safe from any
excess current levels that can make it to overheat thus get damaged.

A relay and a contractor have been used as the switching gears to isolate the
transformer from the power system in case a fault occurs. A LCD has been
used to show system current reading and indicate cases of over-current fault.
All the devices are depend on micro controller to make them operate. A buzzer
have been used which gives alarm in faulty condition.

BLOCK DIAGRAM CIRCUIT DIAGRAM FLOW CHART

CONCLUSION
Here we can conclude that by providing adequate methods of protecting devices like our project we can increases the reliability
and reduce outages. Reducing outages also reduce maintenance costs. Remote indication by SMS decreases the downtime and
re-establishment of power supply can be done quickly.

REFERENCE
Constantin Daniel Oancea," GSM Infrastructure Used for Data Transmission", 7th International Symposium on Advanced Topics in
Electrical Engineering (ATEE), 2011 May 12-14, Page(s): 1 — 4.

PREPARED BY :
PATEL SWATI S (150180109085) DWIVEDI MAYURI V (160183109014)
GHORI KANIZ A (160183109006) SAH RINKY B (160183109029)
GUIDED BY :
ISHAK SHEIKH