PSC Pre Arrival checklist
PSC Pre Arrival checklist
All vessels shall complete this checklist prior to arrival PSC “High Risk Areas” - USA, EU, China, Australia / New
Zealand, Russia, Ukraine, and Canada regardless of vessel flag.
Caution
Any defects found on board that are statutory i.e covered by certification, must be reported to the
ship management office. The Flag Administration and the Port State authority must also be
informed before vessel arrival. Failure to do so will result in an ISM-related PSC finding and
DETENTION.
Fire Safety
Fire Doors
Self-closing devices............................................................................................................. Tested ☐
NO “tie-backs” in use ..................................................................................................Confirmed ☐
IMO Symbols as per fire plan .................................................................................................. Yes ☐
Rubber packing.....................................................................................................Good condition ☐
Fire doors to open in the correct direction as per the fire plan ..................................Confirmed ☐
Fire doors and door frames should not have any holes for bolts. ..............................Confirmed ☐
Fire dampers, including remote controls mechanisms
1) Handles and wires ................................................................................................Good condition ☐
Labelled “open” / “closed” ............................................................................................. Labelled ☐
IMO signage............................................................................................................................. Yes ☐
All flaps ......................................................................................................................... Close fully ☐
Note: Submit photographs of engine room dampers fully closed
Fuel and Lube Quick Closing Valves, including remote controls mechanisms
1) Handles and wires ................................................................................................Good condition ☐
Tested for correct operation ...............................................................................Good condition ☐
Note: Where the vessel is required to change over to LSFO, make additional checks for leakages
after changeover and prior to arrival in port
Bilges/tank tops....................................................................................................................Clean ☐
Buckets under machinery to collect leaks ..................................................................... Removed ☐
Lagging material ...................................................................................................Good condition ☐
Note: Verify sufficient quantity of foam in the tank per capacity information
5) Fixed water spray system ready for immediate use ...................................................Confirmed ☐
Note: FW Supply valve must be checked to be open. All valves correct aligned (OPEN) and to
ensure that the system is FULLY operational. Check the system is in “AUTOMATIC MODE” and not
“MANUAL MODE” and “on.”
6) Fire Detection Panel displays with no faults ...............................................................Confirmed ☐
7) Fire Main in good condition and does not have patches or holes ...............................Confirmed ☐
8) Fire line isolation valves. ................................................................................................... Tested ☐
9) All firefighting suits in satisfactory condition……………………………………………..………….. Confirmed ☐
Note: All face masks should be in good order, no dry rotted rubber mask straps. Jackets, pants
and gloves must not have any holes or rips in the material.
MARPOL Annex I
Oily water Separator (OWS)
1) Separator & 15 ppm alarm .............................................................................................. Working ☐
2) Discharge line .......................................................................................................Good condition ☐
Inside of discharge pipe .......................................................................................................Clean ☐
NO by-pass line fitted to OWS................................................................................................. Yes ☐
Automatic stopping device................................................................................................. Tested ☐
Note: Correct operation of the 3-way valve and sensor flushing interlocks must be verified
All engineers able to demonstrate the operation of the OWS ............................................... Yes ☐
Note: Including the 15ppm alarm of the OCM and showing the data memory of the OCM.
Company Seal and Flexible Hose Program implemented with records .................................. Yes ☐
Oil / Cargo Record Book entries
1) Entries (Bunkering, weekly entries etc.) ...........................................................................Correct ☐
CE verified ORB1...................................................................................................................... Yes ☐
Each entry ............................................................................................................. Countersigned ☐
OWS related tests (Also record any failures if any) ...................................................... Recorded ☐
Tankers only
1) Overboard Discharge Monitoring Equipment (ODME) ............................................ Operational ☐
2) High alarm & high-high alarms is operating w/audio-visual alarms as required .................... Yes ☐
MARPOL Annex VI
Low Sulphur Fuel Regulations
1) IAPP supplement updated to reflect compliance method...........................................Confirmed ☐
Three (3) years of BDN records available .....................................................................Confirmed ☐
BDN shows Sulphur content no greater than 0.5% (or 0.1% for ECA) Sulphur ............... Checked ☐
Note: Unless Scrubber fitted and operational
Change over procedures are properly recorded in the ER logbook........................................ Yes ☐
All ER crew are fully familiar with the changeover procedure........................................... Tested ☐
Note: Where fitted, Exhaust Gas Scrubber should be fully operational and all necessary records up
to date
Emergency Systems
Emergency generator
1) All means of starting .......................................................................................................... Tested ☐
Other self-contained power sources on board (If any) ............................................. Operational ☐
Ship staff can demonstrate on-load test ................................................................................. Yes ☐
Note: SOLAS II-1 The emergency generator must supply power to the emergency switchboard
within a maximum of 45 seconds automatically.
Insulation resistance ................................................................................................... >5 MOhms ☐
Fuel tanks ................................................................................................................................ Full ☐
Emergency Fire Pumps
1) All crewmembers can start pump..……………………………………………………………………………Confirmed ☐
Sufficient pressure to supply 2 hoses on deck……………………………………………………………………..Yes ☐
Priming Unit ………………………………………………………………………………………………………………. Working ☐
All crewmembers can start pump………………………………………………………………………….….Confirmed ☐
Seawater Suction Valve Remote from Outside Engine room……………………………….......Confirmed ☐
Emergency Preparedness drills
1) All officers & crew are ready for fire, abandon ship & confined space rescue drills…..Confirmed ☐
Caution: If launching / testing / drills not completed, have details been recorded in the logbook
and has Flag been notified?
Lifeboat and rescue boat engines .................................................................... Start immediately ☐
Note: Fast Rescue Boats - An effective operational test is to submerge the motor leg in water to a
depth which will cover the cooling inlet ports. The cooling water pump condition and
circulation is verified by observing the cooling water flow through the water flow indication
(tell-tale) hole. Submit photos of testing.
Cold climate precautions for engines...................................................................................... Yes ☐
Boats free of temporary repairs / soft patches....................................................................... Yes ☐
Lifeboat steering systems.....................................................................................Good condition ☐
Launching and embarkation arrangement & poster ............................................Good condition ☐
Posters under emergency lighting .......................................................................................... Yes ☐
Structure and engine for each lifeboat ................................................................Good condition ☐
Fuel tanks ................................................................................................................................ Full ☐
Batteries ...............................................................................................................Good condition ☐
Lifeboat launching arrangements
1) Corrosion/wastage of sheaves/hooks ............................................................................. Checked ☐
On load release gear ....................................................................................................... Working ☐
On load release gear ................................................................................................. Properly set ☐
Davit launch limit switches......................................................................................... Good order ☐
5) Hydraulic pipes and hoses .......................................................................................... Good order ☐
Emergency lighting
a) ................................................................. Functioning correctly ☐
b) .......................................................................... Marked EMGCY ☐
Note: Auxiliary Engine Performance Tests (TEC 07a) must be fully up to date. Monthly test
at maximum sustainable load (min 80% MCR)
2) Automatic starting.............................................................................................................. Tested ☐
3) Planned maintenance items ................................................................... Complete ☐
4) Critical spare parts ............................................................................... Complete ☐
USA – Top 5
1) Engine Room piping insulation ...................................................................... See comments above
2) Electrical Appliances .................................................. Hazard Warning signs posted as required ☐
3) Spare Gas Cylinders .......................................................................................... Properly secured ☐
Rescue Boats .................................................................................................. See comments above
Security: Control of access to vessel ....................................... ISPS / SSP requirements fully met ☐
CHINA –Top 5
1) Fire Fighting Equipment & Appliances:
a) Framework for ER entrance A-Class Fire Door ................................ See comments above
b) Portable fire extinguishers ……………………………………………...……….……Checked and fully operational ☐
c) Fire detection and alarm monitoring system panel ........................ See comments above
2) Sewage treatment plan
a) All components including dosing pump …………………………………………………………………………..Working ☐
b) No modification affecting the validity of ISPP Certificate………………………………………………Confirmed ☐
3) Fire Dampers (Operational / Fully close as designed) ........................... See comments above
4) Lifeboats ................................................................................................ See comments above
5) Garbage Record Book …………………………….……………Completed as per Marpol/Company Requirements ☐
RUSSIA – Top 5
Emergency lighting on Lifeboats/Rescue Boats/ Rafts ............................................. Operational ☐
All navigation and signal lights ............................................................ Checked and operational ☐
3) Emergency Generator .................................................................................... See comments above
4) Rescue boats sub-zero temperatures ........................................................... See comments above
5) Position indicator on Bunker valves ................................................................................ Verified ☐
Ukraine – Top 5
1) Latest Edition of Nautical Publications ............................................................................ Verified ☐
2) Cleanliness of Engine Room & free of minor oil leaks ............................................... Good order ☐
3) Incinerator fully operational and reaches 600°C within 5 minutes .......................... Good order ☐
Note: Conduct additional access control training prior to arrival. PSCO may use fake ID / business
cards to catch out the gangway watch. PSCO may also try to board while gangway watch
distracted by other visitors / operations such as provisions or bunkering.
5) Logbooks and Record Books daily pages signed by Master ....................................... Good order ☐
Canada
1) Rescue Boat Release hook ready for immediate use ....................................................... Verified ☐
2) Galley, galley equipment, and food storage space cleanliness .................................. Good order ☐
3) Rotten and spoiled food discarded from storage areas ...................................... Verified ☐
4) Pressure & Temperature gauges in the engine room ............................................... Good order ☐
5) SOLAS training manual vessel specific and correct LSA equipment included .......... confirmed ☐
Completion / Confirmation
Send the completed checklist to your:
1) Company.
2) DPA, if defective or list below in the comments section unconfirmed items.
Comments:
I have verified, prior to this port arrival, except the above items which are either:
in conformance with applicable international regulations and Company SMS;
Deficiencies have been reported to the company; and
Corrective action has been taken.
COVID-19 Reminder!
The Master has the authority to prohibit boarding of the vessel – or to request a person on board
disembark - to anyone:
-whose temperature exceeds 37.5℃
- who refuses to wear PPE
- who does not agree to comply with shipboard restrictions.
All persons who fail to comply with instructions relating to Covid- for above reasons shall be
reported to their source Company.