CDS_v2.7_ReleaseNotes_en
CDS_v2.7_ReleaseNotes_en
Revision 2.7
Release Notes
Notices
Document Information Warranty Safety Notices
Document No: D0013814 The material contained in this CAUTION
EDITION 04/2022 document is provided “as is,” and is
subject to being changed, without A CAUTION notice denotes a hazard. It
notice, in future editions. Further, to calls attention to an operating
Copyright the maximum extent permitted by procedure, practice, or the like that, if
© Agilent Technologies, Inc. 2022 applicable law, Agilent disclaims all
warranties, either express or implied, not correctly performed or adhered to,
No part of this manual may be with regard to this manual and any could result in damage to the product
reproduced in any form or by any information contained herein, or loss of important data. Do not
means (including electronic storage including but not limited to the implied
and retrieval or translation into a proceed beyond a CAUTION notice
warranties of merchantability and
foreign language) without prior until the indicated conditions are fully
fitness for a particular purpose.
agreement and written consent from Agilent shall not be liable for errors or understood and met.
Agilent Technologies, Inc. as governed for incidental or consequential
by United States and international
copyright laws.
damages in connection with the WARNING
furnishing, use, or performance of this
document or of any information A WARNING notice denotes a hazard.
contained herein. Should Agilent and It calls attention to an operating
Agilent Technologies, Inc. the user have a separate written
5301 Stevens Creek Blvd. agreement with warranty terms procedure, practice, or the like that, if
Santa Clara, CA 95051 covering the material in this document not correctly performed or adhered to,
USA that conflict with these terms, the could result in personal injury or
warranty terms in the separate death. Do not proceed beyond a
agreement shall control.
WARNING notice until the indicated
Software Revision conditions are fully understood and
This guide is valid for the 2.7 or lower
Technology Licenses
met.
revisions of Agilent OpenLab CDS The hardware and/or software
software until superseded. described in this document are
furnished under a license and may be
used or copied only in accordance with
the terms of such license.
Contents
Introduction 4
For our Regulated Customers 4
Introduction
When any change is made to Agilent software, the validation status of the
software needs to be re-established by the user/customer.
Whenever software is changed, a validation analysis should be conducted
not just for the validation of an individual change, but also to determine the
extent and impact of that change on the entire software system.
Version 2.7
Compatibility updates
Added Support for:
• Windows 11 (64-bit): 21H2 (Enterprise or Professional)
• Windows 10 (64-bit): 20H2 or greater (Enterprise or Professional) 1
• OpenLab Server/ECM XT 2.7, includes Basic Server product
• .NET 4.8 (minimum required)
.NET 6.0 (installed by default without removing previous versions)
• PostgreSQL 14.1 (Shared Services, Content Management, and Data
Repository)
• Amazon Web Services (AWS): Tested releases until April 2022
• Microsoft Azure: Tested releases until April 2022
Removed support of
• Windows 10 (P + E) 2004 and 20H1, and Windows 10 (E) 1909
• Oracle 18C, SQL 2014
• Internet Explorer
Compatibility prepared for the subsequent product versions that will release
after OpenLab CDS 2.7 (see the respective release notes for detail):
• EZChrom Migration
• SLIMS
• Match compare
• 2D-LC
• Online LC monitoring
Sample Prep method (.smx) is now saved with results and can be
included in a report
Usability enhancements
• System Preparation Tool (SPT) launched automatically during
installation.
• Option to navigate between launcher tabs using key "Tab" and
"Shift+Tab"; "Enter" or "Space" to select the tab
• During upgrade, installer shows tiles for installed topology only
• New command keys enhance silent mode:
Cmd key “CheckStatusOnly" to avoid automatic change of Windows
settings during SPT runs in silent mode
Ability to set key "DBAdmin", "DBpassword" in cmd or tags
<AdminName>, <ObfuscatedPassword> via configuration file
OpenLab CDS Release Notes 7
Version 2.7
Branding updates
• Installer UI refresh
• Update Launch Icon, splash screen, and login screens
Control Panel
Added Privileges
• New Activity Log Access privilege
Required for view access to the Activity Log.
Upon upgrade the Activity Log Access role is assigned
automatically to all existing users and groups.
Acquisition
Enhanced Calibration
• Calibration may be based on time-based group as reference (if using
linear curve models or fixed response factors)
• Calibration Coefficient of determination (r2) calculations can be
validated for all calibration modes
Acquisition
• Configure the 7100 Agilent CE or CE/MSD instruments using instrument
type Agilent LC & LC/MS.
• Connect to the CE instrument, create methods, and run analyses using
CE specific soft configuration options.
• Review CE analytic data with same feature set as for LC.
• Create reports from CE data with same feature set as for LC.
• Capillary Zone Electrophoresis (CZE) workflow (with or without
corrected area and CE specific calculations).
Driver Updates
Agilent Instrument driver packages shipped with OpenLab CDS 2.7:
RC.NET Instrument Driver Driver Software Installed by
Revision default
Agilent LC & CE 3.4 *
Agilent LC/MS SQ 2.5
Agilent ELSD 1.8
Agilent GC 3.7
Agilent GC/MS SQ 1.4
Agilent Micro GC 2.3
Agilent Gas Analyzer 2.7
Agilent G1888 Headspace B.01.09.2
Agilent 7697A-8697 Headspace 3.3
Agilent 35900E A/D Converter 2.3
Agilent SS420X A/D Converter 1.2
Agilent Data Player 2.4
Agilent CTC PAL 3 2.5
Agilent CTC PAL-xt B.01.08
* LC&CE driver version 3.5 or higher is required to use the extended CE
workflow, for non-RC.Net Method Import (2DLC), and the whole feature set
provided by the Modify instrument configuration in CDS Client
permission.
See the OpenLab CDS media for more details on final component versions.
Version 2.6
Compatibility updates
Workstations, Clients, and Instrument Controllers (AICs) are now
supported on:
• Windows 10 64-bit, Enterprise (1909 or greater), or
Professional (2004 or greater) 2
• OpenLab Server / ECM XT 2.6, includes new Basic Server product
2 For support of LTSC/LTSB, and the most current versions check with your Agilent representative.
System / Installation
New Roles:
• Project Content Deletion
• Content Management Administrator
QualA
New QualA 3.4 release (Test Services) delivered with OpenLab CDS. See
separate QualA Release Notes for details on feature updates
Updated Branding
Redesigned launch Icons, splash screens and login screens, to adjust to new
Agilent branding
Acquisition
Reference Chromatogram
• Added option to define a reference chromatogram in the processing
method and display up to 5 signal specific reference chromatograms in
the chromatogram window
Driver Updates
Agilent Instrument driver packages shipped with OpenLab CDS 2.6:
RC.NET Instrument Driver Driver Software Installed by
Revision default
Agilent LC & CE 3.3
Agilent LC/MS SQ 2.4
Agilent ELSD 1.8
Agilent GC 3.5
Agilent GC/MS SQ 1.4
Agilent Micro GC 2.2
Agilent Gas Analyzer 2.6
Agilent G1888 Headspace B.01.09.1
Agilent 7697A-8697 Headspace 3.1 *
Agilent 35900E A/D Converter 2.3
Agilent SS420X A/D Converter 1.2
Agilent Data Player 2.4
Agilent CTC PAL 3 2.3
Agilent CTC PAL-xt B.01.08
* Both HSS drivers may be co-installed on a system. Installing 3.1 or higher will
upgrade both B.01.09 and B.01.10 drivers. To keep G1888 control install B.01.09.1
after the upgrade.
See OpenLab CDS Requirement guide (CDS_Requirements.pdf) for details.
Version 2.5
Infrastructure Support
3 For support of the most current versions check with your Agilent representative.
4 In virtual environments
5 AICs are supported but not recommended on Windows Server 2016 or 2019, Standard or Data Center
Acquisition
Added injection types for GC dual injection sequence
• Ability to run samples with "Manual/External" or "No
Injection/Instrument Blank" as injection sources in the same dual
sequence.
MS spectrum overlay
• Ability to overlay several color-coded MS Spectrum to compare MS
Spectrum from different samples.
Split TIC SIM signal by Polarity, Fragmentor, and Gain for MS data
• Ability to view separate TIC SIM signals based on Polarity, Fragmentor,
and Gain to provide unique information for each of these different
analytical conditions.
New utility provides users with enhanced data backup and restore
including the ability to:
• Set up scheduled data backups
• Perform immediate data backup
• Supports cold backup or hot backup
New procedure for hot backup and restore of the OpenLab Server and ECM
XT system. Hot backup can be performed while the system continues to
acquire and analyze data.
Driver Updates
Version 2.4
Infrastructure Support
OpenLab CDS version 2.4 is supported in the following configurations:
Workstation Plus, Workstation with file-based storage, and Client/Server.
Workstations, Clients and Agilent Instrument Controllers (AICs) are
supported on:
• Windows 10, Enterprise or Professional, 64-bit (version 1703, 1709, or
1803) 6
• Windows 7 SP1, Enterprise or Professional, 64-bit
Additionally, for networked deployments, clients and AICs are supported on:
• Windows Server 2012 R2, Standard or Datacenter, 64-bit
• Windows Server 2016, Standard or Datacenter, 64-bit
New support for OpenLab ECM as networked security repository for
OpenLab CDS. Supported OpenLab ECM software:
• OpenLab ECM Version 3.5 Update 6 or later is required
• OpenLab ECM Version 3.6
No operating system support has been removed since v2.3.
Acquisition
6 for support of the most current versions check with your Agilent representative
Control Client
• In a multi-user environment, users with the privilege to manually control
an instrument can “take control” of an instrument to modify its
settings. Other users can still submit runs to the instrument run queue,
but only one user can be modifying these settings at a time. This
reduces mistakes in user overlap and allows changes to the instrument
settings to be correctly attributed to the person who is in-control.
Add-ons
Introduction of QualA add-on for OpenLab CDS WorkStation Plus and
Client/Server
• New software qualification tool allowing customers to self-perform
software qualification assessments for future minor software releases.
Version 1.4 of Migration Tools for OpenLab add on to support workstation to
workstation upgrades to CDS 2.4 from the following software:
• ChemStation C.01.05, C.01,06 or C.01.07
• EZChrom A.04.05, A.04.06 or A.04.07
Support for creation and automated export of Allotrope files in OpenLab CDS
WorkStation and Client/Server software. The Allotrope Data Format (ADF)
files are a universal data format, a detailed description of the Allotrope Data
Format and its structure is available on the Allotrope Foundation web site
(https://www.allotrope.org).
• Automated creation of Allotrope Data Format when result
set/injection completes. Consists of the LC-UV analytical raw data
(chromatograms + spectra) plus metadata and the original OpenLab
CDS files.
• Manual export of result set or sequence
Driver Updates
Agilent Instrument driver packages shipped with OpenLab CDS 2.4
RC.NET Instrument Driver Driver Software Revision Installed by
default with
OpenLab
CDS 2.4
Agilent LC A.02.19 SR3 x
Agilent ELSD A,01.07 (build 12)
Agilent LC/MS SQ 2.2.2260 x
Agilent GC 3.0.532 x
Agilent GC/MS SQ 1.3 (build 54) x
Agilent 490 Micro GC B.01.12.1.2125
Agilent Headspace B.01.07.3
Agilent 35900E A/D Converter 2.3 (build 53) x
Agilent SS420X A/D Converter A.01.01 (build 65) x
Agilent Data Player 2.2.6 x
Agilent CTC PAL 3 A.01.04.1
Agilent CTC PAL-xt B.01.08
users can check the “Target points per second” box to specify the
number of points across the peak. The driver software will automatically
calculate the scan time and dwell time to meet the “Target points per
second” setting.
Time Segments in Audit Trail but Not in UI
• Since the scan will be run throughout the time segments, the audit trail
reflects time segment changes although the UI no longer shows time
segments as an option.
Distinguishing Scan Traces with Overlapping Masses
• When there are overlapping masses in multiple “Scan” scan segments
and if all the parameters (fragmentor, gain, polarity) are the same, users
will not be able to distinguish the scan trace that the overlapped mass
came from in Data Analysis. If any of the above parameters is different,
users will be able to distinguish the spectrum data based on the
parameters shown in DA.
Version 2.3
Acquisition
Driver Updates
Driver packages (revision) installed with OpenLab CDS version 2.3:
Agilent LC A.02.19
Agilent LC/MSD A.01.02.35
Agilent GC B.01.03
Agilent GC/MSD A.01.02
Agilent 35900E A/D 2.3.0
Agilent SS420x Interface A.01.01
Agilent Data Player A.02.01
Version 2.2
Infrastructure Support
OpenLab CDS version 2.2 is supported in the following configurations are
Workstation Plus, Workstation with file-based storage, and Client/Server.
Workstations, Clients and Agilent Instrument Controllers can run under the
following:
• Windows 10, Enterprise or Professional, 64 bit
• Windows 7 SP1, Enterprise or Professional, 64 bit
• Windows 8.1, Enterprise or Professional, 64 bit
Acquisition
Automated creation of sequence result folder and name
Project enhancements supporting template file sharing
• Ability to share sequence and templates within multiple projects.
Failover state for operational continuity
• Allow submission of samples through the AIC in case of network connectivity
failure occurs.
Method translation from 68xx to 78xx and Intuvo
• Ability to open acquisition method created on a 68xx and use on 78xx or Intuvo.
Data Analysis
Snapshot via Data Analysis
• Ability to view, process and print from a sample that is being acquired.
Translation and import of MSD ChemStation data format to OpenLab CDS
Enhancement to user permissions and version access in Data Analysis
• Auto-lock result set when e-signing
• Version label will not change when a result set is signed or locked
Add-ons
The following add-ons are supported with OpenLab CDS (*additional licenses may
be required):
• Support for Sample Scheduler for OpenLab
• Support for Gel Permeation Chromatography (GPC)* add-on
• Manual export of data files in legacy formats:
• ChemStation Edition *.D (including ch)
• AIA
• Support for Match Compare for OpenLab*
Driver Updates
Driver packages (revision) installed with OpenLab CDS version 2.2:
Agilent LC A.02.16.6
Agilent LC/MSD A.01.02
Agilent GC B.01.02
Agilent GC/MSD A.01.01
Agilent 35900E A/D 2.3.0
Agilent SS420x Interface A.01.01
Agilent Data Player A.01.02
Other RC.NET drivers included on USB media:
CTC PAL3 A.01.03
PAL XT B.01.08
ELSD A.01.07
Agilent 490 Micro GC B.01.12
Agilent Headspace B.01.07.2
For known issues and workarounds in the OpenLab software at the time of release
see the Software Status Bulletins (SSB), which can be found online at:
http://www.agilent.com/en-us/support/software-informatics/openlab-software-
suite/openlab-chromatography-data-system-(cds)/m84xx
Agilent Community
To get answers to your questions, join over 10,000 users in the Agilent Community.
Review curated support materials organized by platform technology. Ask questions
to industry colleagues and collaborators. Get notifications on new videos,
documents, tools, and webinars relevant to your work.
https://community.agilent.com/
www.agilent.com
© Agilent Technologies, Inc. 2022
Edition 04/2022
D0013814