(Meter) Digital Electricity Meter - Catalog - EN - 201705
(Meter) Digital Electricity Meter - Catalog - EN - 201705
Electricity Meters
LD Series
Digital Electricity Meter
LSIS Digital watt hour meter
The best technique of LSIS generates
innovative meters.
LS Digital W-meter increases space application by
minimizing size, has various types and reliability by
easy maintenance.
2
▣ Various model Contents
It’s possible to do remote inspection by various
standard, pulse output, remote inspection type. ● LD Series 4
Especially, remote inspection product is composed of
● Application 6
communication module. So it’s possible to do remote
inspection gas, water, heating w a t e r, t h e r m a l ● LD Series (Ratings / Dimensions) 8
capacity, air condition-ing facility meter.
● LD Series CT/PT operated meter
LSIS always provides best A/S to our customer, we ● Ratings and specification 18
make the customer ● Diagram 21
3
Digital Electricity Meter
LD Series
Both terminal connection method
Compact size
It is easy to install and increase space usage between cabinet panel and power meter panel because of the
minimizing size.
<mm, kg>
W 130 66 49%
Dimension H
159 130 18%
D 155 65 58%
1.0% accuracy
It is possible to do more accurate inspection because of the 2times increasing of accuracy comparing
with static power meter within error range 1%.
Mechanic Electronic
4
Large LCD
It’s easy to see the inspection value and operating condition by large LCD.
LCD : 19×52mm
Number size : 9×5mm
Indication : 6digit
E G W HW H C ID
▒ Explanation of indication
➊ Normal operation condition :
Blinking time is changed in proportion to using
load current.
➋ Type of metering :
It activates from left side.
➌ Cumulating forward active power consumption :
Indication to first digit
➍ The unit of metering :
electricity(kWh) water/ hot water/heating(l/h) gas(m3/h)
LD series
It is possible to do a remote inspection of meters of electricity, gas, water, heat capacity, air conditioner value
by RS-485 communication.
HCUM
Multi-V
(Outside unit)
Power measurement unit CCU-E2 Note)
Heat Gas Water Hot Heat Gas Water Hot Heat Gas Water Hot
6
Home network system
Gas
Water
RS-485
Hot
CCU-E2 Note)
Inspection center
Web server
Prevention of
crime
Portal Entertainment
7
Digital Electricity Meter
LD Series
Ratings / Dimensions (Direct connection meter)
Up/Down type
25.4
9.1
54
79.2
130
Type LD1210DRM-040(U/D)
Circuit Sys. 1P2W
Current(A) 40(10)
54 35
Voltage(V) 220V, 50/60Hz 66 65
Pulse/kWh 1000
Front Side
Accuracy 1.0
S Standard 18
Option P Pulse type
R Remote inspection
10
126
95
25
6
Bottom
Rear
Left/Right type
130
Type LD1210DRM-040(L/R)
54
65
66
35
18 95 10
Rear Side
8
▒ Single phase 80A
Up/Down type
25.4
9.1
54
79.2
130
Type LD1210DRM-080(U/D)
Circuit Sys. 1P2W
Current(A) 80(20)
54 35
Voltage(V) 220V, 50/60Hz 66 65
Pulse/kWh 500
Front Side
Accuracy 1.0
S Standard 18
Option P Pulse type
R Remote inspection
13
126
95
25 11
Bottom
Rear
Left/Right type
130
Type LD1210DRM-080(L/R)
54
65
66
35
18 95 13
Rear Side
9
Digital Electricity Meter
LD Series
Ratings / Dimensions (Direct connection meter)
Up/Down type
25.4
9.1
54
79.2
130
Type LD1210DRM-120(U/D)
Circuit Sys. 1P2W
Current(A) 120(30)
54 35
Voltage(V) 220V, 50/60Hz 66 65
Pulse/kWh 250
Front Side
Accuracy 1.0
S Standard 18
Option P Pulse type
R Remote inspection
13
126
95
25 11
Bottom
Rear
Left/Right type
130
Type LD1210DRM-120(L/R)
54
65
66
35
Remote inspection
18 95 13
Rear Side
10
▒ 3phase 4wiring 40A
Up/Down type
25.4
9.1
54
79.2
130
Type LD3410DRM-040(U/D)
Circuit Sys. 3P4W
Current(A) 40(10)
Voltage(V) 220/380V, 50/60Hz 100 35
114 65
Pulse/kWh 500
Front Side
Accuracy 1.0
S Standard 18
10
125.6
95
25 25 25 6
Bottom
Rear
Left/Right type
130
65
114
100
35
Type LD3410DRM-040(L/R)
Circuit Sys. 3P4W Top
Current(A) 40(10) 54 9.1
79.2 25.4
Voltage(V) 220/380V, 60Hz
Front
Pulse/kWh 500
Accuracy 1.0
S Standard 125.6
6
18 95 10
Rear Side
11
Digital Electricity Meter
LD Series
Ratings / Dimensions (Direct connection meter)
Up/Down type
25.4
9.1
54
79.2
130
Type LD3410DRM-080(U/D)
Circuit Sys. 3P4W
Current(A) 80(20)
100 35
Voltage(V) 220/380V, 50/60Hz 114 65
Pulse/kWh 250
Front Side
Accuracy 1.0
S Standard
Option P Pulse type
18
R Remote inspection
13
125.6
95
25 25 25 9
Bottom
Rear
Left/Right type
130
65
114
100
35
Type LD3410DRM-080(L/R)
Circuit Sys. 3P4W Top
Current(A) 80(20) 54 9.1
79.2 25.4
Voltage(V) 220/380V, 60Hz
Pulse/kWh 250 Front
Accuracy 1.0
125.6
9
S Standard
Option P Pulse type
25
R Remote inspection
25
25
18 95 13
Rear Side
12
▒ 3phase 4wiring 120A
Up/Down type
25.4
9.1
54
79.2
130
Type LD3410DRM-120(U/D)
Circuit Sys. 3P4W
Current(A) 120(30) 100 35
114 65
Voltage(V) 220/380V, 50/60Hz
Pulse/kWh 125 Front Side
Accuracy 1.0
S Standard
18
13
125.6
95
25 25 25 11
Bottom
Rear
Left/Right type
130
65
114
100
35
Type LD3410DRM-120(L/R)
Circuit Sys. 3P4W Top
Current(A) 120(30) 54 9.1
79.2 25.4
Voltage(V) 220/380V, 60Hz
Pulse/kWh 125 Front
R Remote inspection
25
25
18 95 13
Rear Side
13
Digital Electricity Meter
LD Series
Ratings / Dimensions (CT/PT operated meter)
112
74
95
Type LD3310CTM-005Te
112
Circuit Sys. 3P3W 90
98
Current(A) 5(2.5) Front
Rear
Voltage(V) 220V, 50/60Hz
Pulse/kWh 5000
Accuracy 1.0 4-R5 below
S Standard
26
59
66
69
Pannel
R Remote inspection
76
8
Bottom
4-Ø4.5 100
74
95
Type LD3310CPM-005Te
112 90
Circuit Sys. 3P3W 98
S Standard
26
Pannel
R Remote inspection
76
Bottom
4-Ø4.5 100
112
74
95
Type LD3410CTM-005Te
112 90
Circuit Sys. 3P4W
98
Current(A) 5(2.5) Front
Rear
Voltage(V) 220/380V, 50/60Hz
Pulse/kWh 2500
Accuracy 1.0 4-R5 below
S Standard
26
59
66
69
Pannel
R Remote inspection
76
8
Bottom
100
4-Ø4.5
74
95
Type LD3410CPM-005Te
Circuit Sys. 3P4W 112 90
98
Current(A) 5(2.5)
Front
Voltage(V) 110/190V, 50/60Hz Rear
Pulse/kWh 5000
Accuracy 1.0
4-R5 below
S Standard
26
Pannel
R Remote inspection
76
Bottom
4-Ø4.5 100
122
Type LD3310CTM-005
Circuit Sys. 3P3W
Current(A) 5(2.5) 114 52
94
Rear
122
Type LD3310CPM-005
Circuit Sys. 3P3W
Current(A) 5(2.5) 114 52
Rear
122
Type LD3410CTM-005
Circuit Sys. 3P4W
114 52
Current(A) 5(2.5)
Voltage(V) 220/380V, 50/60Hz Front Side
Pulse/kWh 2500
Accuracy 1.0 57
S Standard
Option P Pulse type
R Remote inspection
Rear 94
122
Type LD3410CPM-005
Circuit Sys. 3P4W
Current(A) 5(2.5) 114 52
Rear
Output rating of pulse IF = 9.5mA, IC < 6mA, VCC < 30V, pulse width : 70mS
Power Under 2W
18
Ratings and specification
Output rating of pulse IF = 9.5mA, IC < 6mA, VCC < 30V, pulse width : 70mS
Power Under 2W
Note) Consider in case of system air-conditioning Remote inspection application and some other external application.
Output rating of pulse IF = 9.5mA, IC < 6mA, VCC < 30V, pulse width : 70mS
Power Under 2W
Note) Consider in case of system air-conditioning Remote inspection application and some other external application.
19
Digital Electricity Meter
Ratings and specification
Output rating of pulse IF = 9.5mA, IC < 6mA, VCC < 30V, pulse width : 70mS
Power Under 2W
Note) Consider in case of system air-conditioning Remote inspection application and some other external application.
Output rating of pulse IF = 9.5mA, IC < 6mA, VCC < 30V, pulse width : 70mS
Power Under 2W
Note) Consider in case of system air-conditioning Remote inspection application and some other external application.
20
Ordering
21
Digital Electricity Meter
Diagram
▒ LD series
1P2W 3P4W
Up/Down
type
Left/Right
type
(Users need
consider about
exchanging between
power supply and load.)
22
Diagram
23
Digital Electricity Meter
Diagram
P1 P2 P3
1S 1L 1S 1L
3S 3L 3S 3L
1S P1 2S P2 3S P3 P0 3L 2L 1L
1S P1 2S P2 3S P3 P0 3L 2L 1L
24
MEMO
25
Digital Electricity Meter
MEMO
26
MEMO
27
www.lsis.com