0% found this document useful (0 votes)
1 views

Bondor Tech Data Sheets - SolarSpan v52

SolarSpan® is an insulated roof panel system designed for commercial and residential use, combining roofing, EPS-FR insulation, and a pre-painted ceiling. It is made from Australian COLORBOND® steel and is suitable for various applications, including educational and retail facilities, with specific testing for cyclonic regions. The technical data sheet provides detailed specifications on panel properties, including thickness, mass, thermal performance, and fire hazard properties.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1 views

Bondor Tech Data Sheets - SolarSpan v52

SolarSpan® is an insulated roof panel system designed for commercial and residential use, combining roofing, EPS-FR insulation, and a pre-painted ceiling. It is made from Australian COLORBOND® steel and is suitable for various applications, including educational and retail facilities, with specific testing for cyclonic regions. The technical data sheet provides detailed specifications on panel properties, including thickness, mass, thermal performance, and fire hazard properties.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

solarspan ®

EPS-FR Technical Data Sheet


Version 52
Current as of: 19/11/21
solarspan ®
EPS-FR Technical Data Sheet
Version 52
Current as of: 19/11/21

Product Description Joint


SolarSpan® is a long-spanning commercial and residential insulated roof panel
system that combines roofing, EPS-FR insulation and a pre-painted ceiling in Certificate CM40145

one durable, functional and attractive roof panel. This all-in-one roofing solution
is manufactured using Australian-made COLORBOND® steel for durability and is
installed in a variety of applications including educational facilities, multi-residential
housing and retail facilities and is tested for use in cyclonic regions.

Panel Properties
Panel Thickness (mm) 50 75 100 125 150 175 200 Services duct

Typical Mass (kg/m2) 10.6 10.9 11.3 11.6 12.0 12.3 12.7
SL Grade Declared λ (W/m.K)
Core EPS-FR
(Expanded Polystyrene with fire retardant)
Profiles
0.042 0.042 0.042 0.042 0.042 0.042 0.042
at 23oC
Width (cover mm) 1000
SL Grade Declared R-value
1.20 1.80 2.40 3.00 3.60 4.25 4.85 Thickness (mm) 50, 75, 100, 125, 150, 175, 200
(m2K/W) at 23oC
Length Up to 24m (check for availability)
SL Grade Total R-value
(m2K/W) at 15oC (Winter)
1.40 2.03 2.65 3.27 3.90 4.52 5.15 Plain
INSULROOF - 50mm - VJ CEILING
External Material 0.42mm G550 COLORBOND® steel
SL Grade Total R-value External Finishes High-Rib Trapezoidal Profile
1.38 1.98 2.57 3.17 3.76 4.35 4.95
(m2K/W) at 30oC (Summer)
Exterior Colour Options Classic Cream™, Surfmist®, Paperbark®,
Note: The Declared R-value is at 23oC in accordance with AS/NZS 4859.1:2018 & AS/NZS
Shale Grey™, Dune®, Pale Eucalypt®,
4859.2:2018.
Manor Red®**, Basalt®^, Woodland VJ
Grey®^**
Span Table Internal Material 0.6mm G300 COLORBOND® steel
NON-CYCLONIC REGION A&B (ROOF APPLICATIONS ONLY)
Internal Finishes Plain, VJ SOLARSPAN - 50mm - VJ CEILING
SL Grade EPS-FR Core / 0.42mm Hi-tensile External / 0.6mm Internal Steel Skins.
Maximum uniformly distributed ultimate wind load (kPa) for the given span: Interior Colour Options Classic Cream , Surfmist
™ ®

Pitch 2 degree minimum


Single Span, wind pressure acting outwards
Panel Thickness (mm)
Paint System AS/NZS 2728 & AS 1397 Dimensions UNCONTROLLED
Span (mm) Acoustic Properties Rw 24 - 25 depending on thickness
50 75 100 125 150 175 200
Material Group Numbers C1.10 Group 1 & 2
25mm R
Designed by
McNallJ
250mm
Drawn by
CoxD
Vendor 185mm
Scale Path & Filename
1:3
QTY.
I:\Operations Development Manager\OPERATIONS
PER MACHINE
20mm
DEVELOPMENT\DRAWINGS-CONTROLLED\PRODUCTS\Bondor\Z-FACE PROFILES\VJ Profile\SOLARSPAN, 50mm -

1500 5.16 7.70 9.41 10.98 13.26 15.51 17.81 3.2 Description VJ.iam
Size Date

32mm
ALL MACHINED SURFACES U.N.O A3

2700 2.35 3.74 4.63 5.55 6.78 7.99 9.28 Bushfire Attack Level BAL-40 (All exposed core to be covered Me te c n o P ty Lim ite d tr a din g a s B o n do r
GENERAL TOLERANCE
BREAK ALL SHARP EDGES
U.N.O.
U.N.O. Material:
Finish:
Rev: Drawing No.
SOLARSPAN, 50mm FLAT-FLAT
Sheet
1 1

3900 1.28 2.00 2.55 3.11 3.67 4.23 4.79 with flashing)
20mm
5100 - 1.21 1.53 1.86 2.19 2.52 2.85 Fire Hazard Properties AS/NZS 1530.3 Thickness
6300 - - 1.04 1.25 1.47 1.69 1.91 Ignitability Index 0 65mm
7500 - - 0.76 0.92 1.07 1.22 1.38
8700 - - - - 0.82 0.94 1.05
Spread of Flame Index 0
1000mm cover width
Heat Evolved Index 0

UNC
Multi-span, wind pressure acting outwards Smoke Index 2-3
Panel Thickness (mm) SMOGRARC < 100
Span (mm)
50 75 100 125 150 175 200 ** Limited availability.
1500 4.15 5.90 7.61 7.74 7.74 7.74 7.75 ^ Darker colours warranted for use in limited regions. Check with your local SolarSpan®
dealer for more information.
2700 2.07 2.91 4.00 4.35 4.35 4.35 4.35
3900 1.17 1.72 2.41 2.95 3.04 3.04 3.05 a. AS5637.1 / AS ISO 9705 - BCA Group Number (Spec C1.10)
EPS-FR steel skinned insulated building panels conform to the requirements of the Bondor® National Network
5100 - 1.11 1.58 1.98 2.35 2.35 2.36 BCA Specification C1.10 as either Group 2 or Group 1 depending on the thickness and
construction detail. BRISBANE / EXPORT MELBOURNE SYDNEY
6300 - - 1.10 1.40 1.77 1.93 1.93 Group 1 103 Ingram Road 6 Dunmore Drive 49 – 53 Newton Road
Panel up to 250mm thick with steel ‘wall-wall’ and ‘wall-ceiling’ angles fixed with steel
7500 - - - 1.03 1.31 1.57 1.64 rivets or screws at maximum 300mm centres is classified as Group 1. Acacia Ridge QLD 4110 Truganina VIC 3029 Wetherill Park NSW 2164
Group 2
8700 - - - - - 1.20 1.43 Panel up to 150mm thick with aluminum ‘wall-wall’ and ‘wall-ceiling’ angles fixed with T: 07 3323 8500 T: 03 8326 8000 T: 02 9609 0888
aluminum rivets or screws at 300mm centres is classified as Group 2. Panel thicker than F: 07 3323 8501 F: 03 8326 8099 F: 02 9729 1114
150mm requires steel ‘wall-wall’ and ‘wall-ceiling’ angles fixed with steel rivets or screws
at 300mm centres to be classified as Group 2.
PERTH ADELAIDE LAUNCESTON
The technical information contained in this document cover a breadth of applications
where SolarSpan® may be used, which may be outside the scope of our Codemark
certificate. Data specific to CodeMark certification can be found on SolarSpan®’s CoC
17 Gauge Circuit 70 – 72 Rundle Road 7 Connector Park Drive Me te c n
Canning Vale WA 6155 Salisbury South SA 5106 Kings Meadows TAS 7249
CM40145.
T: 08 9256 0600 T: 08 8282 5000 T: 03 6335 8500
SPAN TABLE NOTES: F: 08 9256 0620 F: 08 8282 5099 F: 03 6335 8544
1. Extended span tables including cyclonic regions C&D, multi-span, wind pressure acting
inwards and 0.5mm interior skin are also available. Refer Bondor®.
2. Fixing with 14g tek screws (or equivalent) at each rib are required. To connect to your nearest Bondor® branch simply call 1300 300 099 or visit www.bondor.com.au
3. Pressures specified are for wind gusts only per AS/NZS 1170.2.
4. Deflection limit of span/150 applies, and in accordance with Serviceability Limit State
criteria per AS/NZS 1170.0 - TABLE C1. Metecno Pty Limited. ABN 44 096 402 934. The manufacturer reserves the right to change the specification without notice. Bondor®, Equitilt®,
5. Self weight of the panel has been allowed for, plus an allowance of max 25kg/m2 for BondorPanel®, FlameGuard®, MetecnoPanel®, MetecnoInspire®, EconoClad®, MetecnoKasset®, InsulWall®, LuxeWall®, DesignerWall®, SolarSpan®,
light duty fittings (lights, etc.). No other dead loads permitted. InsulRoof®, MetecnoSpan®, Purline®, CoolRoof®, Equideck®, InsulLiving®, Metecno are trademarks of Metecno Pty Limited. BlueScope, COLORBOND®
6. Non-trafficable maintenance access (concentrated load) of 140kg on any span has been Intramax™ and colour names are trademarks of BlueScope Steel Limited. The colours shown in this publication have been reproduced to represent
allowed for, in roof pans only. Avoid stepping on the ribs. actual product colours as accurately as possible. However, given printing limitations, we recommend checking your chosen colour against an actual
7. Distributed live load of 0.25kPa (as per AS/NZS 1170.1) has been allowed for. Bondor® sample before placing orders. This advice is of a general nature only. Designers must provide for adequate structural performance and other Building
tests comply with details outlined in AS 4040.0, AS 4040.1, AS 4040.2, AS 4040.3, AS
Code requirements. This information is subject to change. Refer to Bondor® website for latest version. Consult Bondor® for your application. BON0126
1562.1 and AS/NZS 1170.1.
8. Generic engineering certification of the SolarSpan® Patio System is available for Tech Data Sheets - Solarspan v52.
residential patios. Leaders in Thermal & Architectural Building Solutions

You might also like