Manual Elan-rs485 232 en Rev2 (3)
Manual Elan-rs485 232 en Rev2 (3)
Introduction ........................................................................................................................... 4
Device description ................................................................................................................. 4
Connection ............................................................................................................................ 5
Connection examples ............................................................................................................ 6
Installing, setting IP address .................................................................................................. 8
Logging to the web interface.................................................................................................. 9
Settings.............................................................................................................................10
Settings – description of functions.....................................................................................11
Devices - device management ..........................................................................................19
Scenes - managing scenes ...............................................................................................23
Device control ......................................................................................................................24
Starting up scenes................................................................................................................24
The instruction manual provides information on installing and operating the device. The instruction manual is
always part of the supply. Only perform installation after becoming thoroughly familiar with this User Guide and
device functions. Problem-free function of the device also depends on the way it was shipped, stored and
handled. If you notice any signs of damage, deformation, malfunction or a missing part, do not install this product
and return it to the point of sale. At the end of its service life, the product and its parts must be treated as
electronic waste. Before starting the installation, make sure that all wires and connected parts are not under
voltage. When assembling and performing maintenance, you must uphold safety regulations, standards,
directives and special provisions for working with electrical equipment.
Introduction
• The eLAN-RS485/232 (eLAN-RS) allows you to control from your smart phone, tablet, or by using the Conection
air conditioner and their handheld devices.
• The eLAN-RS485/232 is connected to the home network (router) via the LAN network cable and communicates
with a smartphone.
• Intuitive application environment offers centralized control from one place.
• If you do not have a fixed IP address, the converter will automatically get it from the DHCP server.
• Power converter with 10-27 V DC adapter (included) or PoE 24V DC power supply (router).
• You need a Connection Server (to communicate with the application) to install.
• Set up via web interface.
Device description
USB connector
Button RESET
Indication power
supply
Indication of data
reception
Connection
device device
device
RS323
Recommended connection:
devi323 device
RS323
Connection examples
232
485
System Jablotron
100
485
Pi485
Note: Only one protocol type can be used from the converter, Protocols 232 and 485 do not work concurrently.
https://en.wikipedia.org/wiki/List_of_TCP_and_UDP_port_numbers
Use an Ethernet cable to connect it to your local network. Your local network (router) will allocate the eLAN-RS IP
address. By default, automatic IP address retrieval (DHCP) is set on eLAN-RS.
You can find the IP address using the ELKO Finder, where you type in ELAN RS485-232
After clicking Search devices, the program searches for all RS converters on your network.
Name: admin
Password: elkoep
Login options:
It is possible to log into the eLAN-RF-Wi-003 web interface either as the administrator (admin) with full
access to controls and settings, or as the user (user), for whom only the panel itself is displayed.
The user thus only has the option of controlling the device (the factory setting of the password for logging
in as admin and user is: elkoep).
Both users log into the same dialog field (Login, Password), but each uses his/her own name and
password.
Note: to RESET the eLAN-RS press the (> 10s) button on the front panel of the transmitter for a long time. The IP
address and login data will return to the factory settings, automatic IP address retrieval (DHCP) is set.
The default login password for both admin and user is: elkoep.
Settings
When you log in, you will see a window in the browser where you will see a tab for setting up, adding devices, and
adding a scene.
Click on the name eLAN-RS485/232 to display the eLAN-RS485/232 converter information dialog box.
Accounts allows you to change your login credentials for your admin or user account. Click
on Edit account to display the data entry dialog.
Load - restore the backup settings that you have previously saved to your PC (the file has a .bin extension).
Network settings: allows you to configure network settings, change network settings.
Note: After changing the IP address (static address setting), you need to use the new IP address to log in to
eLAN-RS. If the connection is not working after entering the new IP address, you must reconfigure the connected
device (PC) to the same subnet.
To update FW eLAN-RS:
1. Download the latest version of FW for eLAN-RS from the Web site.
2. Click the Update button to select the downloaded file (the FW update file must always contain the * bin
extension).
Pressing the OK button, this automatically starts the FW update in your eLAN-RS.
Note: do not turn off device or use the Reset button when updating the firmware. The eLAN-RS restarts after
updating. After the firmware update, all settings will remain preserved. This means that the set IP, login data,
visualization panel will remain the same as with the SW version prior to the update.
Set Interface - it is necessary to select the interface to communicate with the device (RS485 or RS232).
When selecting the communication mode, Baudrate, Length data bits, Stop bit and Parity are automatically set
according to the default specification of the device.
We recommend comparing the initial settings in the device's manual to verify that the parameters are set
correctly. In case there were any changes on the device side, it is necessary to edit them manually in the
Communication mode folder in eLAN.
Note: Any device name can be selected. Currently, the EVO48, EVO96, EVO192, DGP-848, DGP-NE96 control
panels are supported.
To check if the eLAN is communicating with the device, click DEVICE states to read the device data.
If Jablotron is used to determine the section or detector number, use the appropriate SW.
Section status X.
DISARMED
ARMED
AREA X STATUS
FORCE ARMED
STAY ARMED
INSTANT ARMED
S List of active flags in section X.
OK (no flag active)
STROBE
IN ALARM
AREA X FLAG
IN PROGRAMMING
NOT READY
TROUBLE
ZONE IN MEMORY
Detector status X.
CLOSED
ZONE X STATUS OPEN
TAMPERED
FIRE LOOP TROUBLE
List of active flags in detector X.
OK (no flag active)
LOW BATTERY
ZONE X FLAG
SUPERVISION LOST
FIRE ALARM
IN ALARM
When using Paradox, read the section number from the control panel.
Here the IP address of the NTP server is set by default, which determines for the eLAN the precise time via the
Internet. If your eLAN-RS is not connected to internet network, then time is always set to 12:00 AM
You can also set the time zone in which the eLAN is located.
The current day is set manually with button Set manual time.
You can add, edit, delete, manage actions associated with the device, and view device status.
Device control
- Click Devices to see a list of items from a device that can be controlled.
Starting up scenes