The eLAN-RS485/232 is a device that allows control of various systems via smartphone or tablet, connecting to a home network and supporting protocols RS232 and RS485. The manual provides detailed instructions on installation, IP address setup, device management, and scene control, emphasizing safety and proper handling. Users can manage devices and settings through a web interface, with options for firmware updates and communication mode configurations.

Uploaded by

drszantosi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

Manual Elan-rs485 232 en Rev2 (3)

The eLAN-RS485/232 is a device that allows control of various systems via smartphone or tablet, connecting to a home network and supporting protocols RS232 and RS485. The manual provides detailed instructions on installation, IP address setup, device management, and scene control, emphasizing safety and proper handling. Users can manage devices and settings through a web interface, with options for firmware updates and communication mode configurations.

Uploaded by

drszantosi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

eLAN-RS485/232

02-66/2017 / rev.2 Page 1 of 24


4.12.2019
eLAN-RS485/232

Introduction ........................................................................................................................... 4
Device description ................................................................................................................. 4
Connection ............................................................................................................................ 5
Connection examples ............................................................................................................ 6
Installing, setting IP address .................................................................................................. 8
Logging to the web interface.................................................................................................. 9
Settings.............................................................................................................................10
Settings – description of functions.....................................................................................11
Devices - device management ..........................................................................................19
Scenes - managing scenes ...............................................................................................23
Device control ......................................................................................................................24
Starting up scenes................................................................................................................24

02-66/2017 / rev.2 Page 2 of 24


4.12.2019
eLAN-RS485/232

Before you begin

The instruction manual provides information on installing and operating the device. The instruction manual is
always part of the supply. Only perform installation after becoming thoroughly familiar with this User Guide and
device functions. Problem-free function of the device also depends on the way it was shipped, stored and
handled. If you notice any signs of damage, deformation, malfunction or a missing part, do not install this product
and return it to the point of sale. At the end of its service life, the product and its parts must be treated as
electronic waste. Before starting the installation, make sure that all wires and connected parts are not under
voltage. When assembling and performing maintenance, you must uphold safety regulations, standards,
directives and special provisions for working with electrical equipment.

02-66/2017 / rev.2 Page 3 of 24


4.12.2019
eLAN-RS485/232

Introduction

Congratulations on your purchase of the eLAN-RS485/232 converter.

• The eLAN-RS485/232 (eLAN-RS) allows you to control from your smart phone, tablet, or by using the Conection
air conditioner and their handheld devices.
• The eLAN-RS485/232 is connected to the home network (router) via the LAN network cable and communicates
with a smartphone.
• Intuitive application environment offers centralized control from one place.
• If you do not have a fixed IP address, the converter will automatically get it from the DHCP server.
• Power converter with 10-27 V DC adapter (included) or PoE 24V DC power supply (router).
• You need a Connection Server (to communicate with the application) to install.
• Set up via web interface.

Device description
USB connector

Supply connector 10- Ethernet Connector


27 V max. / 200 mA (RJ45)

Button RESET
Indication power
supply

Connection Terminals Connection Terminals


RS232 RS485

Indication of data
reception

02-66/2017 / rev.2 Page 4 of 24


4.12.2019
eLAN-RS485/232

Connection

RS485 bus connection

device device

* 120R - Integrated in eLAN-RS485 / 232


** Plug in if the 120R is not integrated in the connected device

Bus connection RS232

device
RS323

Recommended connection:

devi323 device
RS323

02-66/2017 / rev.2 Page 5 of 24


4.12.2019
eLAN-RS485/232

Connection examples

1. Wiring Example using protocol 232:

232

Integration Module EZS Paradox


PRT3 EVO 192
Alarm control panel

2. Wiring Example using protocol 485:

485

JA-121T EZS Jablotron

System Jablotron
100

3. Wiring Example using protocol 485:

485

LG Air conditioning Outdoor unit


RS

Pi485

Note: Only one protocol type can be used from the converter, Protocols 232 and 485 do not work concurrently.

02-66/2017 / rev.2 Page 6 of 24


4.12.2019
eLAN-RS485/232

List of usable ports:

More detailed description of the port use:

https://en.wikipedia.org/wiki/List_of_TCP_and_UDP_port_numbers

02-66/2017 / rev.2 Page 7 of 24


4.12.2019
eLAN-RS485/232

Installing, setting IP address

Use an Ethernet cable to connect it to your local network. Your local network (router) will allocate the eLAN-RS IP
address. By default, automatic IP address retrieval (DHCP) is set on eLAN-RS.

You can find the IP address using the ELKO Finder, where you type in ELAN RS485-232

Please download the latest version of ELKO Finder: https://www.elkoep.com/converter-elan-rs485232-en

After clicking Search devices, the program searches for all RS converters on your network.

02-66/2017 / rev.2 Page 8 of 24


4.12.2019
eLAN-RS485/232

Logging to the web interface


Start a web browser.
In the Internet browser, type the IP address of your eLAN-RS to the Address bar.
Once the specified IP address is confirmed, the web server login page is loaded.
The factory settings for signing in as administrator are:

Name: admin
Password: elkoep

Login options:

 It is possible to log into the eLAN-RF-Wi-003 web interface either as the administrator (admin) with full
access to controls and settings, or as the user (user), for whom only the panel itself is displayed.
 The user thus only has the option of controlling the device (the factory setting of the password for logging
in as admin and user is: elkoep).
 Both users log into the same dialog field (Login, Password), but each uses his/her own name and
password.

 Confirm the log in by pressing: Login.

Note: to RESET the eLAN-RS press the (> 10s) button on the front panel of the transmitter for a long time. The IP
address and login data will return to the factory settings, automatic IP address retrieval (DHCP) is set.

The default login password for both admin and user is: elkoep.

02-66/2017 / rev.2 Page 9 of 24


4.12.2019
eLAN-RS485/232

Settings

When you log in, you will see a window in the browser where you will see a tab for setting up, adding devices, and
adding a scene.

Click on the name eLAN-RS485/232 to display the eLAN-RS485/232 converter information dialog box.

02-66/2017 / rev.2 Page 10 of 24


4.12.2019
eLAN-RS485/232

Settings – description of functions

 Accounts allows you to change your login credentials for your admin or user account. Click
on Edit account to display the data entry dialog.

 Load & Save settings

Load - restore the backup settings that you have previously saved to your PC (the file has a .bin extension).

Save - backup of current eLAN-RS settings including network settings.

02-66/2017 / rev.2 Page 11 of 24


4.12.2019
eLAN-RS485/232

Network settings: allows you to configure network settings, change network settings.

Note: After changing the IP address (static address setting), you need to use the new IP address to log in to
eLAN-RS. If the connection is not working after entering the new IP address, you must reconfigure the connected
device (PC) to the same subnet.

02-66/2017 / rev.2 Page 12 of 24


4.12.2019
eLAN-RS485/232

 Firmware update enables firmware update (FW) in eLAN-RS485/232.

To update FW eLAN-RS:
1. Download the latest version of FW for eLAN-RS from the Web site.
2. Click the Update button to select the downloaded file (the FW update file must always contain the * bin
extension).
Pressing the OK button, this automatically starts the FW update in your eLAN-RS.

Note: do not turn off device or use the Reset button when updating the firmware. The eLAN-RS restarts after
updating. After the firmware update, all settings will remain preserved. This means that the set IP, login data,
visualization panel will remain the same as with the SW version prior to the update.

 Communication mode allows you to set the communication mode.

You can set these types of communication modes:


TCP-RS485/232 Bridge, Modbus RTU, Nilan, Air Pohoda, Jablotron, LG PI485, Paradox, Daikin,
Mitsubishi, Cairox, Aseko, Misol MeteoStation

Converter specification for selected TCP-RS485 / 232 Bridge communication mode:


• Only one client can be connected to a TCP port at a time.
• Bridge listens on TCP port 53.
• The recommended maximum message size is 2kB (otherwise data on the serial line may be lost).
• Recommended maximum size of message sent to TCP is 1kB.
• Received data from the serial line are sent to TCP when the send buffer is full (1kB) or in case of 10ms idle time
on the serial line.

Set Interface - it is necessary to select the interface to communicate with the device (RS485 or RS232).

When selecting the communication mode, Baudrate, Length data bits, Stop bit and Parity are automatically set
according to the default specification of the device.

We recommend comparing the initial settings in the device's manual to verify that the parameters are set
correctly. In case there were any changes on the device side, it is necessary to edit them manually in the
Communication mode folder in eLAN.

02-66/2017 / rev.2 Page 13 of 24


4.12.2019
eLAN-RS485/232

Jablotron setup example: Jablotron setup example:

Note: Any device name can be selected.

02-66/2017 / rev.2 Page 14 of 24


4.12.2019
eLAN-RS485/232

Paradox settings example: Paradox creation example:

Note: Any device name can be selected. Currently, the EVO48, EVO96, EVO192, DGP-848, DGP-NE96 control
panels are supported.

To check if the eLAN is communicating with the device, click DEVICE states to read the device data.

Example of reading data from Jablotron:

02-66/2017 / rev.2 Page 15 of 24


4.12.2019
eLAN-RS485/232

After loading, 4 sections will appear:

Status of individual sections. The maximum number of sections is 15.


OFF (section deactivated)
BLOCKED (section blocked)
SERVICE (section under maintenance)
SECTION STATE
READY (section is normal)
ARMED_PART (section partially secure)
ARMED (section is secured)

States of individual PG outputs. The maximum number of PG outputs is 32.


PG STATE OFF - PG output is inactive
ON - PG output is active
States of individual detectors. The maximum number of detectors is 192 (the number depends
on the installation)
PRF STATE
true - the detector is active
false - the detector is inactive
List of active flags in the section.
OK (no flag active)
INTERNAL_WARNING (internal siren active)
EXTERNAL_WARNING (external siren active)
SYSTEM FLAGS FIRE_ALARM (fire alarm)
INTRUDER_ALARM (intruder alarm)
PANIC_ALARM (panic alarm)
ENTRY (entrance delay)
6 - Exit delay

If Jablotron is used to determine the section or detector number, use the appropriate SW.

Example of reading data from Paradox:

02-66/2017 / rev.2 Page 16 of 24


4.12.2019
eLAN-RS485/232

After loading, 4 sections will appear:

Section status X.
DISARMED
ARMED
AREA X STATUS
FORCE ARMED
STAY ARMED
INSTANT ARMED
S List of active flags in section X.
OK (no flag active)
STROBE
IN ALARM
AREA X FLAG
IN PROGRAMMING
NOT READY
TROUBLE
ZONE IN MEMORY
Detector status X.
CLOSED
ZONE X STATUS OPEN
TAMPERED
FIRE LOOP TROUBLE
List of active flags in detector X.
OK (no flag active)
LOW BATTERY
ZONE X FLAG
SUPERVISION LOST
FIRE ALARM
IN ALARM

When using Paradox, read the section number from the control panel.

 Reboot to restart the device eLAN-RS485/232.

02-66/2017 / rev.2 Page 17 of 24


4.12.2019
eLAN-RS485/232
 Date & Time allows you to set the date and time.

Here the IP address of the NTP server is set by default, which determines for the eLAN the precise time via the
Internet. If your eLAN-RS is not connected to internet network, then time is always set to 12:00 AM

You can also set the time zone in which the eLAN is located.

Daylight Saving Time will activate daylight saving time settings.

The current day is set manually with button Set manual time.

During power failure, time information is erased from eLAN memory.

02-66/2017 / rev.2 Page 18 of 24


4.12.2019
eLAN-RS485/232

Devices - device management

Click the Devices tab to see a list of created devices.

You can add, edit, delete, manage actions associated with the device, and view device status.

 Add - add devices.


Selected communication mode defines maximal amount of connectable devices.

Modbus RTU 5 LG PI485 10


Modbus ASCII 5 Paradox 1
Nilan 5 Daikin 10
Air Pohoda 1 Mitsubishi 10
Jablotron 1 Cairox 10

02-66/2017 / rev.2 Page 19 of 24


4.12.2019
eLAN-RS485/232

 Edit allows you to edit previously created device.

 Delete allows you to delete a previously created device.

02-66/2017 / rev.2 Page 20 of 24


4.12.2019
eLAN-RS485/232
 Actions - allows actions to be managed for devices that support adding, editing, or deleting actions.
Devices that enable this feature include Modbud RTU and Nilan communication devices.

Edit Device actions


- Name - any name describing the function.
- Type - null, bool - true-false for write and read,
int - for writing and reading a numerical value,
Number - read only numeric values in 100x format.
- Register - the address of the registry to be written to the device (specified in the device manual).
- Function code - the code determines what write or read is and in which register (holding, input ...),
specifies the MODBUS protocol.

02-66/2017 / rev.2 Page 21 of 24


4.12.2019
eLAN-RS485/232
 States u allows you to view a status list from your device.
You will see a list of items for setting device value, device overlay, or just read-only items.

02-66/2017 / rev.2 Page 22 of 24


4.12.2019
eLAN-RS485/232

Scenes - managing scenes

Scenes are used to control multiple predefined settings.


Example: when the air conditioner is switched on, the temperature is set to 20°C and the fan power is set to
medium speed.

Click the Scenes tab to see a list of created scenes.


You can add, edit, delete, and run scenes.

 Add – add scene.

 Edit allows editing of scenes.

02-66/2017 / rev.2 Page 23 of 24


4.12.2019
eLAN-RS485/232

 Delete – delete scene

 Trigger starts the scene.

Device control

- Mobile phone help application

- Click Devices to see a list of items from a device that can be controlled.

Starting up scenes

- Click the Trigger button in the Scenes section.

02-66/2017 / rev.2 Page 24 of 24