The SmartX IP Controller – RP-C is a fully programmable, IP-based field controller designed for HVAC applications, supporting both standalone and EcoStruxure BMS configurations. It features a dual-port Ethernet switch, wireless connectivity, and a versatile mix of I/O points across four models, enabling flexible network topologies and efficient engineering. The controller supports mobile commissioning, local operation, and integrates with SmartX Sensors for enhanced building management capabilities.

Uploaded by

Francisco Viltes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

RP-C Specification Sheet

The SmartX IP Controller – RP-C is a fully programmable, IP-based field controller designed for HVAC applications, supporting both standalone and EcoStruxure BMS configurations. It features a dual-port Ethernet switch, wireless connectivity, and a versatile mix of I/O points across four models, enabling flexible network topologies and efficient engineering. The controller supports mobile commissioning, local operation, and integrates with SmartX Sensors for enhanced building management capabilities.

Uploaded by

Francisco Viltes
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 17

EcoStruxure™ Building www.schneider-electric.

com/buildings | 1

RP-C
SmartX IP Controller

Introduction IP connectivity and flexible network topologies


SmartX IP Controller – RP-C is a room-purpose, fully The SmartX IP controllers are based on open protocols
programmable, IP based field controller that suits a that simplify interoperability, IP configuration, and
wide range of HVAC applications. The RP-C can either device management:
be used as a standalone BACnet/IP field controller or
as part of an EcoStruxure BMS with a SmartX AS-P or • IP addressing
AS-B server or an Enterprise Server as the parent
• BACnet/IP communications
server. The RP-C features a wireless chip that allows
the mobile commissioning application to connect • DHCP for easy network configuration
directly to the controller.
The SmartX IP controllers have a dual-port Ethernet
The RP-C has the following features: switch, which enables flexible network topologies:

• IP enabled with dual port Ethernet switch • Star


• Full range of controller models • Daisy chain
• Versatile onboard I/O point mix • Rapid Spanning Tree Protocol (RSTP) ring
• Optional covers
In a star topology, the controller and the parent
• Wireless connectivity EcoStruxure BMS server are individually connected to
an Ethernet switch. Daisy-chain multiple controllers
• High reliability
together to reduce installation time and cost. Use an
• Sensor bus for living space sensors RSTP ring topology when you want failures of a single
controller to be detected and recovered quickly and
• Room bus for future support of connected room
efficiently.
solutions
• Mobile commissioning application Full range of controller models
• Full EcoStruxure Building Operation software The RP-C comes in four different models, which offer
support, providing efficient engineering tools four different sets of I/O point types, named 12A, 12B,
12C, and 16A. The RP-C-12A, -12B, and -12C models
support 24 VAC/DC power supply, whereas the RP-C-
16A model is a 230 VAC model.

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 2

RP-C
SmartX IP Controller

Models with a versatile mix of I/O points


The RP-C-12A, -12B, -12C, and -16A models provide
12 or 16 I/O points, consisting of four different sets of
I/O point types. The versatile mix of I/O point types
match a wide variety of applications. The universal
inputs/outputs are highly flexible and can be
configured as either inputs or outputs.

Freely programmable
The freely programmable RP-C models provide
flexibility through support of both Script and Function
Block programming options. The RP-C promotes
efficiency and standardization through the use of
standard controller applications.

I/O Point Types by RP-C Models

I/O Point Types RP-C-12A model RP-C-12B model RP-C-12C model RP-C-16A model
Universal I/O 8 8 4 8
Type Ub
Solid-state relay outputs 4 - 4 4
(MOSFET)
Relay outputs - 3 3 3
Form A
High power relay outputs - 1 1 1
Form C

Configurations by I/O Point Types

Configurations Universal I/O Solid-state Relay Relay Outputs High Power Relay
Type Ub Outputs Form A Outputs
(MOSFET) Form C
Digital inputs yes - - -
Counter inputs yes - - -
Supervised inputs yes - - -
Voltage inputs yes - - -
(0 to 10 VDC)
Current inputs yes - - -
(0 to 20 mA)
Temperature inputs yes - - -
Resistive inputs yes - - -
2-wire RTD temperature yes - - -
inputs

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 3

RP-C
SmartX IP Controller

Continued

Configurations Universal I/O Solid-state Relay Relay Outputs High Power Relay
Type Ub Outputs Form A Outputs
(MOSFET) Form C
Voltage outputs yes - - -
(0 to 10 VDC)
Digital outputs - yes yes yes
Digital pulsed outputs - yes yes yes
PWM outputs - yes yes yes
Tristate outputs - yes yes -
Tristate pulsed outputs - yes yes -

Universal inputs/outputs High power relay output


The universal inputs/outputs are ideal for any mix of The high power relay output is of type Form C. The
temperature, pressure, flow, status points, and similar normally-open (NO) contact is ideal for switching
point types in a building control system. resistive loads of up to 12 A, such as electrical heating
elements. The normally-closed (NC) contact can be
As counter inputs, the universal inputs/outputs are used to switch inductive loads of up to 3 A.
commonly used in energy metering applications. As
RTD inputs, they are ideal for temperature points in a Optional covers
building control system. As supervised inputs, they are
used for security applications where it is critical to know All RP-C models can be equipped with optional covers
whether or not a wire has been cut or shorted. These to reduce access to the screw terminals and wires if
events provide a separate indication of alarms and desired.
events in the system.

For all analog inputs, maximum and minimum levels


can be defined to automatically detect over-range and
under-range values.

The universal inputs/outputs are capable of supporting


analog outputs of type voltage outputs. Therefore, the
universal inputs/outputs support a wide range of
devices, such as actuators.

Solid-state relay outputs


The solid-state relay (SSR) outputs can be used in
many applications to switch 24 VAC or 24 VDC on or off
for external loads such as actuators, relays, or
indicators. The SSR outputs are isolated from the
controller. SSRs are silent and do not suffer from relay
contact wear.

Relay outputs RP-C with equipped with optional covers


The relay outputs support digital Form A point types.
The Form A relays are designed for direct load
applications.

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 4

RP-C
SmartX IP Controller

Wireless connectivity The sensor bus provides both power and


communications for up to four sensors that are daisy-
RP-C is a Bluetooth Low Energy (BLE) enabled chained using standard Cat 5 (or higher) cables. The
product. You can use this wireless connectivity option maximum number of sensors that can be connected to
for connecting a smartphone or tablet running the a controller varies depending on the sensor model and
eCommission SmartX Controllers mobile application to the combination of cover and sensor base type:
the RP-C.
• Blank covers: Up to four sensors of any
High reliability combination of sensor base types
The SmartX IP controllers support local trends, • 3-button and touchscreen covers:
schedules, and alarms, enabling local operation when
the controller is offline or used in standalone – Up to two sensor bases with CO2 option
applications. – Up to four sensor bases without CO2 option
The battery-free power backup of the memory and real- • SmartX LCD temperature sensors: Up to four
time clock helps prevent data loss and allows seamless sensors are supported
and quick recovery after a power disruption.
The maximum total length of the sensor bus is 61 m
WorkStation allows you to update the firmware of (200 ft). For more information, see the SmartX Living
multiple SmartX IP controllers at the same time and with Space Sensors Specification Sheet.
minimum down time. The EcoStruxure BMS server
keeps track of the installed firmware to support backup, Room bus for future support of connected room
restore, and replacement of the controllers and
sensors. The server can host controllers of different
solutions
firmware versions. Through the Room bus, the RP-C is hardware-prepared
for future support of connected room solutions that
Sensor bus for living space sensors include equipment for control of electric lights, window
blinds, and so on.
The SmartX IP controllers provide an interface
designed for the SmartX Sensor family of living space
sensors. The SmartX Sensors offer an efficient way to
Mobile commissioning application
sense the temperature, humidity, CO2, and occupancy The eCommission SmartX Controllers mobile
in a room. The SmartX Sensors are available with application is designed for local configuration, field
different combinations of sensor types and various deployment, and commissioning of SmartX IP
covers and user interface options, such as controllers. The mobile application reduces the
touchscreen, setpoint and override buttons, and blank commissioning time, allows flexibility in project
covers. execution, and minimizes dependencies on network
infrastructure.

The mobile application is designed for use with


Android, Apple (iOS), and Microsoft Windows 10
devices. For more information, see the eCommission
SmartX Controllers Specification Sheet.

SmartX Sensors

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 5

RP-C
SmartX IP Controller

Full EcoStruxure Building Operation software


support
The power of the SmartX IP controllers is fully realized
when it is part of an EcoStruxure BMS, which provides
the following benefits:

• WorkStation/WebStation interface
• Script and Function Block programming options
• Device discovery
• Engineering efficiency

WorkStation/WebStation interface
WorkStation and WebStation provide a consistent user
experience regardless of which EcoStruxure BMS
eCommission SmartX Controllers mobile app server the user is logged on to. The user can log on to
the parent EcoStruxure BMS server to engineer,
Using the eCommission SmartX Controllers mobile commission, supervise, and monitor the SmartX IP
application, you can connect to one or many RP-Cs. controller and its I/O as well as its attached SmartX
You can connect to a single RP-C using the controller's Sensors. For more information, see the WorkStation and
built-in Bluetooth connectivity or using the WebStation specification sheets.
eCommission Bluetooth Adapter connected to a
SmartX Sensor. You can connect to a network of RP-Cs Script and Function Block programming options
on the local IP network, using a wireless access point The freely programmable RP-C controller models have
or a network switch. both Script and Function Block programming options.
Existing programs can easily be reused between the
Device configuration EcoStruxure BMS server and the controller.
With the eCommission SmartX Controllers mobile
application, you can easily discover SmartX IP Device discovery
controllers on the IP network and change each The enhanced Device Discovery in WorkStation
controller's configuration, including the BACnet and IP enables you to easily identify SmartX IP controllers on a
network settings, location, and parent server. To save BACnet network and to associate the controllers with
engineering time, you can save common device their parent server.
settings and then reuse them for controllers of the same
model. Engineering efficiency
Field deployment and I/O checkout The engineering and maintenance of SmartX IP
controllers can be done very efficiently using the
The eCommission SmartX Controllers mobile EcoStruxure Building Operation reusability features.
application does not require an EcoStruxure BMS With these features, you can create library items
server or a network infrastructure to be in place. You (Custom Types) for a complete controller application
can use the mobile application to load the controller that contains programs and all necessary objects such
application directly into the local SmartX IP controller as trends, alarms, and schedules. The controller
and deploy the controller. The controller application application in the Custom Types library is reusable
can be created offline using Project Configuration Tool across all controllers of the same model. You can use
or WorkStation. You can use the mobile application to the controller application as a base for creating new
change the behavior of an installed standard controller controllers intended for similar applications. You can
application, such as configuring temperature setpoints. then edit the controller application, and the changes
You can also perform an I/O checkout to verify that the are automatically replicated to all controllers, while
controller's I/O points are configured, wired, and each controller keeps its local values.
operating correctly.

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 6

RP-C
SmartX IP Controller

WorkStation supports both online and offline tool also enables the quick creation of your own
engineering of SmartX IP controllers. You can make the templates based on SmartX IP controller applications
configuration changes online or use database mode to that you have developed. This facilitates a standard
make the changes offline. In database mode, the approach and drives the ability to easily reuse and
changes are saved to the EcoStruxure Building duplicate common controller applications. For more
Operation database so that you can apply the changes information, see the Automated Engineering Tool
to the controllers later. specification sheet.

Project Configuration Tool enables you to perform all


the engineering off site, without the need for physical
hardware, which minimizes the time you need to spend
on site. You can run the EcoStruxure BMS servers
virtually and engineer the SmartX IP controllers, before
you deploy your server and controller applications to
the servers and controllers on site. For more
information, see the Project Configuration Tool
specification sheet.

In addition, you can use Automated Engineering Tool to


facilitate your engineering process when using SmartX
IP controllers. This tool provides access to a library of
standard controller applications. These standard
applications can be quickly configured and customized
using the wizards and mass edit functions provided in Library of standard HVAC applications
the tool and then loaded into your target server. The

Part Numbers

Product Part number


RP-C-12A-F-24V SXWRCF12A10001
RP-C-12B-F-24V SXWRCF12B10001
RP-C-12C-F-24V SXWRCF12C10001
RP-C-16A-F-230V SXWRCF16A10002
Optional covers SXWRPCCOV10001
DIN-RAIL-CLIP, DIN-rail end clip SXWDINEND10001
package of 25 pieces
eCommission Bluetooth Adapter SXWBTAECXX10001

Specifications
AC input
RP-C-12A, -12B, and -12C models
Nominal voltage......................................................................................................................................................24 VAC
Operating voltage range........................................................................................................................................+/-15 %
Frequency ............................................................................................................................................................50/60 Hz
Maximum power consumption ..................................................................................................................................23 VA
Power input protection................................................................................................MOV suppression and internal fuse

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 7

RP-C
SmartX IP Controller

RP-C-16A model
Nominal voltage....................................................................................................................................................230 VAC
Operating voltage range........................................................................................................................................+/-10 %
Frequency ............................................................................................................................................................50/60 Hz
Maximum power consumption ..................................................................................................................................65 VA
Power input protection................................................................................................MOV suppression and internal fuse
...........................................................................Separate PTC thermistor used as a resettable fuse for 24 VAC Out only
DC input
RP-C-12A, -12B, and -12C models
Nominal voltage.............................................................................................................................................24 to 30 VDC
Operating voltage range ...............................................................................................................................21 to 33 VDC
Maximum power consumption................................................................................................................................... 14 W
Power input protection................................................................................................MOV suppression and internal fuse
AC output
RP-C-16A model
Nominal voltage......................................................................................................................................................24 VAC
Frequency ............................................................................................................................................................50/60 Hz
Power rating ..............................................................................................................................................................19 VA
Environment
RP-C-12A, -12B, and -12C models
Ambient temperature, operating ..................................................................0 to 50 °C (32 to 122 °F) at normal operation
............................................................-40 to +60 °C (-40 to +140 °F) for rooftop applications, horizontal installation only
Ambient temperature, storage ..............................................................................................-20 to +70 °C (-4 to +158 °F)
Maximum humidity.....................................................................................................................95 % RH non-condensing
RP-C-16A model
Ambient temperature, operating ..................................................................................................0 to 50 °C (32 to 122 °F)
Ambient temperature, storage ..............................................................................................-20 to +70 °C (-4 to +158 °F)
Maximum humidity.....................................................................................................................95 % RH non-condensing
Material
Plastic flame rating .............................................................................................................................................UL94-5VB
Ingress protection rating ............................................................................................................................................IP 20

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 8

RP-C
SmartX IP Controller

Mechanical
Dimensions...................................................................................... 180 W x 110 H x 64 D mm (7.1 W x 4.3 H x 2.5 D in.)

Weight, RP-C-12A model......................................................................................................................0.420 kg (0.925 lb)


Weight, RP-C-12B and -12C models ....................................................................................................0.440 kg (0.970 lb)
Weight, RP-C-16A model......................................................................................................................0.800 kg (1.764 lb)
Weight, optional covers ........................................................................................................................0.080 kg (0.176 lb)
Installation ........................................................................................................................................DIN rail or flat surface
Terminal blocks..........................................................................................................................................................Fixed
Software compliance
EcoStruxure Building Operation software .............................................................................................version 2.1 or later
Agency compliances
RP-C-12A, -12B, and -12C models
Emission ..................................................RCM; EN 61000-6-3; EN 50491-5-2; FCC Part 15, Sub-parts A and C, Class B
Immunity ...............................................................................................................................EN 61000-6-2; EN 50491-5-3
Radio.....................................................................................................................................................EN 300 328 V2.1.1
Safety .........................................................................EN 60730-1; EN 60730-2-11; EN 50491-3; UL 916 C-UL US Listed
Fire performance in air-handling spacesa ............................................................................................................ UL 2043
a) The RP-C-12A, -12B, and -12C models are approved for plenum applications.
RP-C-16A model
Emission .....................................................................................................................RCM; EN 61000-6-3; EN 50491-5-2
Immunity ...............................................................................................................................EN 61000-6-2; EN 50491-5-3
Radio.....................................................................................................................................................EN 300 328 V2.1.1
Safety ................................................................................................................EN 60730-1; EN 60730-2-11; EN 50491-3
Energy........................................................................................................................eu.bac Certified Product; EN 15500
Real-time clock
Accuracy, at 25 °C (77 °F) ..............................................................................................................+/-1 minute per month

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 9

RP-C
SmartX IP Controller

Backup time, at 25 °C (77 °F)...................................................................................................................................7 days


Communication ports
Ethernet ................................................................................................................................ Dual 10/100BASE-TX (RJ45)
USB .................................................................... USB 2.0, 5 VDC, 2.5 W, 1 device port (mini-B) and 1 host port (type-A)
Sensor Bus ............................................................................................................................24 VDC, 2 W, RS-485 (RJ45)
Sensor Bus protection ...........................................Transient voltage suppressors on communication and power signals
Room Bus..............................................................................................................................24 VDC, 3 W, RS-485 (RJ45)
Room Bus protection .............................................Transient voltage suppressors on communication and power signals
Communications
BACnet..........................................................................................................BACnet/IP, port configurable, default 47808
...................................................................................................BTL B-AAC (BACnet Advanced Application Controller)a
a) See the BTL Product Catalog for up-to-date details on BTL listed firmware revisions on BACnet International's home
page.
Wireless connectivity
Bluetooth Low Energy (BLE)
Communication protocol .........................................................................................Bluetooth® 4.2 Low Energy compliant
.....................................................................................................................................................Bluetooth® 5 Advertising
Frequency............................................................................................................................................2.402 to 2.480 GHz
Maximum communication distance ........................................................................................Line-of-sight: 100 m (328 ft)
Antenna ............................................................................................................................................... Integrated antenna
RF connector for external antenna.............................................................................................................SMA connector
CPU
Frequency ........................................................................................................................................................... 500 MHz
Type ........................................................................................................................................ARM Cortex-A7 single-core
Internal SRAM.............................................................................................................................................................6 MB
NOR flash memory ...................................................................................................................................................32 MB
Memory backup.......................................................................................................................128 kB, FRAM, non-volatile
Universal inputs/outputs
Channels, RP-C-12A model................................................................................................................... 8 Ub, Ub1 to Ub8
Channels, RP-C-12B model................................................................................................................... 8 Ub, Ub1 to Ub8
Channels, RP-C-12C model....................................................................................................................4 Ub, Ub1 to Ub4
Channels, RP-C-16A model................................................................................................................... 8 Ub, Ub1 to Ub8
Absolute maximum ratings .......................................................................................................................-0.5 to +24 VDC
A/D converter resolution ..........................................................................................................................................16 bits
Universal input/output protection........................................Transient voltage suppressor on each universal input/output
Digital inputs
Range .........................Dry contact switch closure or open collector/open drain, 24 VDC, typical wetting current 2.4 mA
Minimum pulse width ..............................................................................................................................................150 ms

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 10

RP-C
SmartX IP Controller

Counter inputs
Range .........................Dry contact switch closure or open collector/open drain, 24 VDC, typical wetting current 2.4 mA
Minimum pulse width ................................................................................................................................................20 ms
Maximum frequency..................................................................................................................................................25 Hz
Supervised inputs
5 V circuit, 1 or 2 resistors
Monitored switch combinations.............................................................Series only, parallel only, and series and parallel
Resistor range ................................................................................................................................................1 to 10 kohm
For a 2-resistor configuration, each resistor must have the same value +/- 5 %
Voltage inputs
Range ..............................................................................................................................................................0 to 10 VDC
Accuracy...............................................................................................................................+/-(7 mV + 0.2 % of reading)
Resolution................................................................................................................................................................1.0 mV
Impedance..........................................................................................................................................................100 kohm
Current inputs
Range ................................................................................................................................................................0 to 20 mA
Accuracy..........................................................................................................................+/-(0.01 mA + 0.4 % of reading)
Resolution....................................................................................................................................................................1 μA
Impedance .............................................................................................................................................................47 ohm
Resistive inputs
10 ohm to 10 kohm accuracy .......................................................................................................+/-(7 + 4 x 10-3 x R) ohm
R = Resistance in ohm
10 kohm to 60 kohm accuracy .....................................................................................+/-(4 x 10-3 x R + 7 x 10-8 x R2) ohm
R = Resistance in ohm
Temperature inputs (thermistors)
Range................................................................................................................................-50 to +150 °C (-58 to +302 °F)
Supported thermistors
Honeywell .............................................................................................................................................................20 kohm
Type I (Continuum) ...............................................................................................................................................10 kohm
Type II (I/NET) .......................................................................................................................................................10 kohm
Type III (Satchwell) ...............................................................................................................................................10 kohm
Type IV (FD) ......................................................................................................................................................... 10 kohm
Type V (FD w/ 11k shunt) ....................................................................................................................Linearized 10 kohm
Satchwell D?T......................................................................................................................................Linearized 10 kohm
Johnson Controls .................................................................................................................................................2.2 kohm
Xenta....................................................................................................................................................................1.8 kohm
Balco.......................................................................................................................................................................1 kohm
Measurement accuracy
20 kohm...................................................................................................-50 to -30 °C: +/-1.5 °C (-58 to -22 °F: +/-2.7 °F)

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 11

RP-C
SmartX IP Controller

...................................................................................................................-30 to 0 °C: +/-0.5 °C (-22 to +32 °F: +/-0.9 °F)


.................................................................................................................. 0 to 100 °C: +/-0.2 °C (32 to 212 °F: +/-0.4 °F)
.............................................................................................................100 to 150 °C: +/-0.5 °C (212 to 302 °F: +/-0.9 °F)
10 kohm, 2.2 kohm, and 1.8 kohm.......................................................-50 to -30 °C: +/-0.75 °C (-58 to -22 °F: +/-1.35 °F)
..........................................................................................................-30 to +100 °C: +/-0.2 °C (-22 to +212 °F: +/-0.4 °F)
.............................................................................................................100 to 150 °C: +/-0.5 °C (212 to 302 °F: +/-0.9 °F)
Linearized 10 kohm .................................................................................-50 to -30 °C: +/-2.0 °C (-58 to -22 °F: +/-3.6 °F)
...............................................................................................................-30 to 0 °C: +/-0.75 °C (-22 to +32 °F: +/-1.35 °F)
.................................................................................................................. 0 to 100 °C: +/-0.2 °C (32 to 212 °F: +/-0.4 °F)
.............................................................................................................100 to 150 °C: +/-0.5 °C (212 to 302 °F: +/-0.9 °F)
1 kohm ..............................................................................................-50 to +150 °C: +/-1.0 °C (-58 to +302° F: +/-1.8 °F)
RTD temperature inputs
Supported RTDs......................................................................................................................................................Pt1000
Pt1000
Sensor range .....................................................................................................................-50 to +150 °C (-58 to +302 °F)

SmartX IP Controller device environment Sensor range Measurement accuracy


0 to 50 °C (32 to 122 °F) -50 to +70 °C (-58 to +158 °F) +/-0.5 °C (+/-0.9 °F)
0 to 50 °C (32 to 122 °F) 70 to 150 °C (158 to 302 °F) +/-0.7 °C (+/-1.3 °F)
-40 to +60 °C (-40 to +140 °F) -50 to +150 °C (-58 to +302 °F) +/-1.0 °C (+/-1.8 °F)

RTD temperature wiring


Maximum wire resistance.........................................................................................................20 ohm/wire (40 ohm total)
Maximum wire capacitance.......................................................................................................................................60 nF
The wire resistance and capacitance typically corresponds to a 200 m wire.
Voltage outputs
Range ..............................................................................................................................................................0 to 10 VDC
Accuracy..............................................................................................................................................................+/-60 mV
Resolution.................................................................................................................................................................10 mV
Minimum load resistance ........................................................................................................................................5 kohm
Load range.......................................................................................................................................................-1 to +2 mA
Relay outputs, DO
Channels, RP-C-12A model..............................................................................................................................................0
Channels, RP-C-12B model ....................................................................................................................... 3, DO1 to DO3
Channels, RP-C-12C model ........................................................................................................................3, DO5 to DO7
Channels, RP-C-16A model ........................................................................................................................3, DO5 to DO7
Contact rating ..........................................................................................................................................Pilot Duty (C300)
.............................................................................................................................................Min. current: 100 mA (5 VDC)
............................................................................................................Resistive load: 250 VAC/30 VDC, 4 A (cos phi = 1)
........................................................................................................Inductive load: 250 VAC/30 VDC, 4 A (cos phi = 0.4)
Switch type....................................................................................................................................................Form A Relay
....................................................................................................................................................Single Pole Single Throw
....................................................................................................................................................................Normally Open

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 12

RP-C
SmartX IP Controller

Commons.......................................................................................COM1 for DO1, DO2, and DO3 (on RP-C-12B model)


.............................................................................COM3 for DO5, DO6, and DO7 (on RP-C-12C and RP-C-16A models)
Isolation contact to system ground....................................................................................................................3,000 VAC
Cycle life ........................................................................................................................................At least 100,000 cycles
Minimum pulse width ..............................................................................................................................................100 ms
High power relay outputs, DO
Channels, RP-C-12A model..............................................................................................................................................0
Channels, RP-C-12B model.................................................................................................................................... 1, DO4
Channels, RP-C-12C model ................................................................................................................................... 1, DO8
Channels, RP-C-16A model.................................................................................................................................... 1, DO8
Contact rating ..........................................................................................................................................Pilot Duty (B300)
....................................................................Normally Open contact, resistive load: 250 VAC/24 VDC, 12 A (cos phi = 1)
...............................................................Normally Closed contact, inductive load: 250 VAC/24 VDC, 3 A (cos phi = 0.4)
Switch type....................................................................................................................................................Form C Relay
...................................................................................................................................................Single Pole Double Throw
.................................................................................................................................Normally Open and Normally Closed
Isolation contact to system ground....................................................................................................................5,000 VAC
Cycle life ........................................................................................................................................At least 100,000 cycles
Minimum pulse width ..............................................................................................................................................100 ms
Solid-state relay outputs, DO
Channels, RP-C-12A model ....................................................................................................................... 4, DO1 to DO4
Channels, RP-C-12B model..............................................................................................................................................0
Channels, RP-C-12C model ....................................................................................................................... 4, DO1 to DO4
Channels, RP-C-16A model ....................................................................................................................... 4, DO1 to DO4
Output rating ...............................................................................................................................Max. 2 A load per output
...................................................................................................................................Max. 4 A total load for the 4 outputs
AC voltage range ......................................................................................................................................24 VAC +/-20 %
DC voltage range ............................................................................................................................................0 to 50 VDC
Commons .....................................................................COM1 for DO1 and DO2 (on RP-C-12A, -12C, and -16A models)
.....................................................................................COM2 for DO3 and DO4 (on RP-C-12A, -12C, and -16A models)
When the SSR outputs are used to switch AC, the common terminals can be connected to maximum 30 VAC or to
ground. When the SSR outputs are used to switch DC, the common terminals can be connected to maximum 50 VDC
or to ground.
Common voltage, high side output (AC)........................................................................................................Max. 30 VAC
Common voltage, low side output (AC) .....................................................................................................0 VAC (ground)
Common voltage, positive terminal (DC) .......................................................................................................Max. 50 VDC
Common voltage, negative terminal (DC) .................................................................................................0 VDC (ground)
Minimum pulse width ..............................................................................................................................................100 ms
Solid-state relay output protection ...................Transient voltage suppressor across each solid-state relay (SSR) output

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 13

RP-C
SmartX IP Controller

Terminals • Individual 24 VDC power sources to the field must


be current limited to maximum 4 A for UL
For protection from excess current that could be compliant installations, and maximum 6 A in other
produced by field wiring, follow these instructions: areas.
<!!>TO BE CONFIRMED</!!>
For more information on wiring, see Hardware
• All RP-C models have several RET terminals for Reference Guide.
connection of I/O returns, so a common
chassis/signal ground rail is optional and may not
be needed.

RP-C-12A model (24 VAC/DC)

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 14

RP-C
SmartX IP Controller

RP-C-12B model (24 VAC/DC)

RP-C-12C model (24 VAC/DC)

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 15

RP-C
SmartX IP Controller

RP-C-16A model (230 VAC)

Part Numbers in AMER Region for Network Connectivity Accessories

Product descriptiona Part number (AMER region)


Cat 6 field-term plug, UTP ACTPG6TLU001
Cat 6 pass-through plug, UTP, 100-pack ACTPG6PTU100
Actassi crimping tool ACTTLCPT
Cat 6 cable, UTP, 1000 ft (305 m), CMP, green ACT4P6UCP1ARXGR
Cat 6 patch cord, UTP, 30 ft (9 m), CMP, green ACTPC6UBCP30AGR
Cat 6 patch cord, UTP, 50 ft (15 m), CMP, green ACTPC6UBCP50AGR
Cat 6 patch cord, UTP, 70 ft (21 m), CMP, green ACTPC6UBCP70AGR
Cat 6 patch cord, UTP, 90 ft (27 m), CMP, green ACTPC6UBCP90AGR
Cat 5e pass-through plug, UTP, 100-pack ACTPG5EPTU100
Cat 5e cable, UTP, 1000 ft (305 m), CMP, green ACT4P5EUCP1ARXGR
Cat 5e patch cord, UTP, 30 ft (9 m), CMP, green ACTPC5EUBCP30AGR
Cat 5e patch cord, UTP, 50 ft (15 m), CMP, green ACTPC5EUBCP50AGR
Cat 5e patch cord, UTP, 70 ft (21 m), CMP, green ACTPC5EUBCP70AGR
Cat 5e patch cord, UTP, 90 ft (27 m), CMP, green ACTPC5EUBCP90AGR

a) For more information, see the Product Selection Guide (SmartX IP Controllers - Accessories). Abbreviations: UTP (Unshielded Twisted Pair), CMP (Plenum-rated
cable)

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 16

RP-C
SmartX IP Controller

Part Numbers in EMEA Region for Network Connectivity Accessories

Product descriptiona Part number (EMEA region)


Cat 6 field-term plug, UTP ACTPG6TLU001
Cat 6 pass-through plug, UTP, 100-pack ACTPG6PTU100
Actassi crimping tool ACTTLCPT
Cat 6 cable, UTP, 305 m (1000 ft), Euroclass D, green VDICD116118
Cat 6 patch cord, UTP, 10 m (32 ft), LSZH, green ACTPC6UBLS100GR
Cat 6 patch cord, UTP, 15 m (49 ft), LSZH, green ACTPC6UBLS150GR
Cat 6 patch cord, UTP, 20 m (65 ft), LSZH, green ACTPC6UBLS200GR
Cat 6 patch cord, UTP, 25 m (82 ft), LSZH, green ACTPC6UBLS250GR
Cat 5e pass-through plug, UTP, 100-pack ACTPG5EPTU100
Cat 5e cable, UTP, 1000 ft (305 m), Euroclass D, green VDICD115118
Cat 5e patch cord, UTP, 10 m (32 ft), LSZH, green ACTPC5EUBLS100GR
Cat 5e patch cord, UTP, 15 m (49 ft), LSZH, green ACTPC5EUBLS150GR
Cat 5e patch cord, UTP, 20 m (65 ft), LSZH, green ACTPC5EUBLS200GR
Cat 5e patch cord, UTP, 25 m (82 ft), LSZH, green ACTPC5EUBLS250GR

a) For more information, see the Product Selection Guide (SmartX IP Controllers - Accessories). Abbreviations: UTP (Unshielded Twisted Pair), CMP (Plenum-rated
cable), LSZH (Low Smoke Zero Halogen)

Part Numbers in Pacific Region for Network Connectivity Accessories

Product descriptiona Part number (Pacific region)


Cat 6 field-term plug, UTP ACTPG6TLU001
Cat 6 pass-through plug, UTP, 100-pack ACTPG6PTU100
Actassi crimping tool ACTTLCPT
Cat 6 cable, UTP, 305 m (1000 ft), PVC, green 2D4P6IPV3B-GR
Cat 6 patch lead, UTP, 10 m (32 ft), PVC, green RJ6_100PL-GR
Cat 6 patch lead, UTP, 15 m (49 ft), PVC, green RJ6_150PL-GR
Cat 6 patch lead, UTP, 20 m (65 ft), PVC, green RJ6_200PL-GR
Cat 6 patch lead, UTP, 25 m (82 ft), PVC, green RJ6_250PL-GR
Cat 5e pass-through plug, UTP, 100-pack ACTPG5EPTU100
Cat 5e cable, UTP, 305 m (1000 ft), PVC, green 2D4P5IPV3B-GR
Cat 5e patch lead, UTP, 10 m (32 ft), PVC, green RJ5_100PL-GR
Cat 5e patch lead, UTP, 15 m (49 ft), PVC, green RJ5_150PL-GR
Cat 5e patch lead, UTP, 20 m (65 ft), PVC, green RJ5_200PL-GR
Cat 5e patch lead, UTP, 25 m (82 ft), PVC, green RJ5_250PL-GR

a) For more information, see the Product Selection Guide (SmartX IP Controllers - Accessories). Abbreviations: UTP (Unshielded Twisted Pair), PVC (Polyvinyl
chloride)

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.
EcoStruxure™ Building www.schneider-electric.com/buildings | 17

RP-C
SmartX IP Controller

Regulatory Notices
Federal Communications Commission CE - Compliance to European Union (EU)
FCC Rules and Regulations CFR 47, Part 15, Class B 2014/53/EU Radio Equipment Directive (RED)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two 2014/30/EU Electromagnetic Compatibility Directive
conditions: (1) This device may not cause harmful interference. (2) This device must accept 2014/35/EU Low Voltage Directive
any interference received, including interference that may cause undesired operation. 2011/65/EU Restriction of Hazardous Substances (RoHS) Directive
This equipment complies with the rules, of the Official Journal of the European Union, for
Industry Canada governing the Self Declaration of the CE Marking for the European Union as specified in the
This Class B digital apparatus complies with Canadian ICES-003. above directive(s) per the provisions of the following standards: EN 60730-1, EN 60730-2-
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. 11, and EN 50491-3 Safety Standards.

Regulatory Compliance Mark (RCM) - Australian Communications and Media


Authority (ACMA) WEEE - Directive of the European Union (EU)
This equipment complies with the requirements of the relevant ACMA standards made under This equipment and its packaging carry the waste of electrical and electronic equipment
the Radiocommunications Act 1992 and the Telecommunications Act 1997. These (WEEE) label, in compliance with European Union (EU) Directive 2012/19/EU, governing the
standards are referenced in notices made under section 182 of the Radiocommunications disposal and recycling of electrical and electronic equipment in the European community.
Act and 407 of the Telecommunications Act.

UL 916 Listed products for the United States and Canada, Enclosed Energy
Management Equipment. UL file E80146.
eu.bac - European Building Automation and Controls Association. Certified
Product.
This product is certified by eu.bac and conforms to the quality and energy performance
criteria outlined by the following European product standard: EN 15500.
All eu.bac certified products are found on the eu.bac web site www.eubaccert.eu

www.schneider-electric.com

03-XX017-XX-en, DRAFT
© 2018 Schneider Electric. All rights reserved. Trademarks and registered trademarks are the property of their respective owners.

You might also like