1008S-XP
Flow Indicator-Totalizer
1008S 1008S-XP
Features
Masibus' Model 1008S/ 1008S-XP has features and performance you
Input selectable from current, voltage & frequency
will find only in high end flow computers, like high accuracy, high Available in two options
resolution, PT compensation and fast sampling to measure and totalize 1008S: Panel mount
with precision even fast changing flow rates. The unit has a 5-digit flow 1008S-XP: Wall mount, Dual Compartment, Ex-proof
rate display and an 8-digit batch total/ integrated total display with (IP65, Gas Group, IIA/IIB) with touch sense keys
rollover counts. All Totalized data and configured parameters are Square root extractor
stored in non-volatile memory and retained during power off and 5 Digit Flow rate & 8 digit Batch/ Integrated Total with
rollover count
power disruptions. Model 1008S is available in Panel mount option, Programmable K factor for Freq Input
whereas 1008S-XP is available in Ex-proof, Wall mount Dual Programmable low/zero cutoff facility
Compartment enclosure having touch sensitive keys for operation. 8-digit totalizer with password protected resetting
Programmable time base Day/Hr/Min/Sec
Flow Totalizer has optional four relays, 2 for flow rate and 2 for batch Programmable zero flow rate
total, the flow rate relays can be setup for Hi/Lo Alarm and the batch Pulse output
total relays for Pre and Final batch total. 1008S also has optional four Mass flow measurement with additional Pressure and
Temperature I/P
digital inputs to operate the totalizing function remotely. RS485 and
Gas/ liquid flow measurement
flow rate Re-transmission option allows easy interface with Superheated steam flow measurement
PLC/DCS/SCADA systems. A selectable square root extractor Saturated steam flow measurement
function enables compatibility with DP transmitters without built-in Options:
square root extractor. DI inputs for remote operation
Mass Flow Measurement
Flow Totalizer is field selectable for mA/V DC or frequency flow rate 4 Configurable relays for Flow/Batch
input signal, for 4-20mA 2 wire transmitter it has a 24V DC Retransmission output (Isolated)
transmitter supply as a standard, the input signal can be scaled from RS485 serial communication (Isolated)
0 to 30000 engineering value and the time base is selectable from Applications
Sec/Min/Hour/Day, for frequency input the K factor is user Monitoring and controlling continuous and batch flow
programmable, the unit also has an option to accept 2 more dc processes like:
signals for pressure and temperature compensation for liquid/gas Mixing operation in chemical/Pharma
flow, saturated steam or super heated steam measurement. Fuel consumption
Custody Transfer
Energy management
Batch Filling
Receiver instrument for Turbine, PD & Magnetic pickup
flow elements
www.masibus.com [email protected]
TECHNICAL SPECIFICATIONS
Input Output
Input 1 Relay (Optional)
Current 0/4-20mA 2 Relays Programmable for Flow Rate or Batch Alarm
Voltage 0/1-5V DC 2 Relays Programmable for Flow Rate Alarm
4 Relays
ADC Resolution 16 bits & 2 Relays Programmable for Batch Alarm
Sampling Speed 10 Samples/Sec Contact Type C-NO-NC Single change over
Input impedance Rating 250V AC/30V DC@2A
Current Input 250 Ω Retransmission (Optional)
Voltage Input > 300K Ω Type Isolated 4-20 mA DC @ 500 Ω
NMRR > 50dB Accuracy 0.25% of FS +1 count
CMRR > 100dB Serial Communication (RS485) (Optional)
Time Base Accuracy 100 ppm Baud Rate (bps) 9600/19200, Programmable
Measurement Accuracy 0.025% FS [for Current / Voltage] Protocol Modbus-RTU
Polarity Protection Provided Data Pattern N, 8,1
Temp-co 100 ppm Transmitter Power Supply 24V DC ±5% @ 50 mA
0-10KHz Power Supply
Frequency Input*
*Max. Pulse level<=24V, Min. pulse level > 5.0V
85-265V AC @ 50Hz (Standard)
Input 2 (Optional) Power Supply
24V DC ±10% (Optional)
Current 0/4-20mA
Power Consumption <10 VA
Voltage 0/1-5V DC
Measurement Accuracy 0.025% FS [for Current / Voltage] Isolation (Withstanding voltage)
Pressure/Temperature Compensation Between primary terminals* and secondary terminals**: At least 1500 V AC for 1 minute
Purpose Between primary terminals* and grounding terminal: At least 1500 V AC for 1 minute
for Standard Vol. flow/Mass Flow
Between grounding terminal and secondary terminals**: At least 1500 V AC for 1 minute
Input 3 (Optional) Between secondary terminals**: At least 500 V AC for 1 minute
RTD 100.0 – 235.0 °C * Primary terminals indicate power terminals and relay output terminals.
Resolution 0.1 °C ** Secondary terminals indicate analog/digital I/O and Communication O/P.
Accuracy 0.25% Insulation resistance: 50MΩ or more @ 500V DC between power terminals and
Digital Input (Optional) grounding terminal.
No. of Channels 4 Nos. Physical
Input Type Dry Contact/Open Collector
1008S 1008S-XP
Exc. Voltage/Current 12V DC@10mA
Wall mount using 4 Nos
Stop batch, Integration total zero, Mounting type Panel
Input Function of M8 size bolts
Start batch, Batch total zero
Dimension (mm) 96(H)x96(W)x125(D) 340(H) X 186(W) X 110(D)
Display & Keys Panel Cut-out (mm) 92(H) X 92(W) NA
Process Value 0.56” 5 Digit, 7 Segment RED LED Weight 500 grams 6 Kgs
Total/Int. Value 0.4” 8 Digit, 7 Segment RED LED Ingress Protection IP20 IP65
Rate Indication Range Range programmable 0-30000 Zone 1 & 2,
Totalizing Range 0-99999999 Area Classification Safe
Gas Group: IIA & IIB
Decimal Point Adjustable Explosion Proof, Aluminum
Resolution 1 Count Enclosure Type ABS Plastic Alloy LM-6, Ex-d,
Keys Stop, Start, Escape & Enter Dual Compartment
Special Features Electrical Connection/ Cable
2.5mm² / Screwed 3/4” ET – 5 NOS
Batch/Integrated Total Reset Front Key (Password Protected) entry size
Time Base for Totalizer Programmable (Day / Hr /Min / Sec) Environmental
K Factor Function Yes (Frequency I/P) Operating Temperature 0 to 55 °C
Square Root Extraction For Differential Pressure Transmitter Storage Temperature 0 to 80 °C
NVRAM/EEPROM. Data will not be lost Operating Humidity 30 - 95%RH (non condensing)
Memory/Data storage
when power off, can hold for 10 years Warm-up time >10 min
With Two extra compensating I/P for
Mass Flow Measurement
Pressure and Temperature
ORDERING CODE
Retransmission Type of Flow No of extra Glands
Model Input Types Digital Input Power Supply Communication Relay
O/P Measurement (only for 1008S-XP)#
1008S X X XX X X X XX X
1008S-XP C 4-20mA N None A1 85-265V AC N None N None N None N None (with single I/P) N None
PT Compensated
D 0-20mA Y Yes A3 24V DC 2 RS485 2 2 Relays Y Yes PT 1 1 extra gland
liquid/ gas flow
E 1-5V DC 4 4 Relays SS Saturated Steam Flow 2 2 extra glands
F 0-5V DC SH Super heated Steam 3 3 extra glands
G 0-10V DC
N 0-10 KHz
S Special*
Standard Accessory
2 nos mounting clamps alongwith 1008S model
X – Specify from table 2 nos 3/4" ET Cable glands and 3 blind plugs alongwith 1008S-XP model