5''QB (1)
5''QB (1)
Quality Documentation
Package
5" OD 19.5 LB./FT. .362 WT IEU UPSET Range 2 GRADE S-135 DRILL STRING
WITH GPDS50 6.063 Bevel PIN 6.625" OD X 3.25" ID 9" TONG SPACE WITH Arnco
350XT HARDBANDING & WITH SE None & WITH H-Series BENCHMARKS AND
GPDS50 6.063 Bevel BOX 6.625" OD X 3.25" ID 12" TONG SPACE WITH Arnco
350XT HARDBANDING & WITH SE None & WITH H-Series BENCHMARKS, TK-34
COATING
Grant Prideco
NAVASOTA, TX, USA
www.nov.com/GrantPrideco/CustomerFeedback
Drill Pipe Performance Sheet
www.NOV.com/GrantPrideco Phone: +1 (281) 878-8000
SmoothEdge Height Nominal Tool Joint Worn to Bevel Worn to Min TJ OD for
Not Raised OD Diameter API Premium Class
Box OD (in) 6.625 6.625 6.063 5.930
Elevator Capacity (lbs) 1,440,200 1,440,200 823,600 685,600
Note: Elevator capacity based on assumed Elevator Bore, no wear factor, and contact stress of 110,100psi.
Assumed Elevator Bore Diameter (in) 5.219 Note: A raised elevator OD increases elevator capacity without affecting make-up torque.
Pipe Body Slip Crushing Capacity Pipe Body Configuration ( 5 (in) OD 0.362 (in) Wall S-135 )
Nominal 95 % Inspection Class API Premium Class
Slip Crushing Capacity (lbs) 498,300 472,800 396,500
Note: Slip Crushing: Slip crushing load is calculated with the Spiri-Reinhold equation from “Why Does Drill Pipe
Assumed Slip Length (in) 16.5 Fail in the Slip Area” World Oil, 1959 for the slip length and transverse load factor shown and is for reference
only. Slip crushing is dependent on the slip design and condition, coefficient of friction, loading conditions, time in
Transverse Load Factor (K) 4.2 slips, drill pipe OD and wall variation, and other factors. Consult with the slip manufacturer for additional
information.
Pipe Body Performance Pipe Body Configuration ( 5 (in) OD 0.362 (in) Wall S-135 )
Nominal 95 % Inspection Class API Premium Class
Pipe Tensile Strength (lbs) 712,100 673,800 560,800
Pipe Torsional Strength (ft-lbs) 74,100 70,000 58,100
TJ/PipeBody Torsional Ratio 0.97 1.03 1.24
80% Pipe Torsional Strength (ft-lbs) 59,300 56,000 46,500
Burst (psi) 17,105 18,571 15,638 Note: Nominal Burst
calculated at 87.5% RBW
Collapse (psi) 15,672 14,292 10,029 per API.
Pipe OD (in) 5.000 4.964 4.855
Wall Thickness (in) 0.362 0.344 0.290
Nominal Pipe ID (in) 4.276 4.276 4.276
Cross Sectional Area of Pipe Body (in^2) 5.275 4.991 4.154
Cross Sectional Area of OD (in^2) 19.635 19.352 18.514
Cross Sectional Area of ID (in^2) 14.360 14.360 14.360
Section Modulus (in^3) 5.708 5.395 4.476
Polar Section Modulus (in^3) 11.415 10.790 8.953
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully
responsible for the accuracy and suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied
warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear
conditions (remaining body wall) is for information only and does not represent or imply acceptable operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance
ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box ID’s, tool joint ID refers to
the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
Pipe Body 95 % Inspection Class Pipe Body OD (in) 5 Wall Thickness (in) 0.362 Pipe Body Grade S-135
Combined Loading for Drill Pipe at Combined Loading for Drill Pipe at
Maximum Make-up Torque = 43,100 (ft-lbs) Minimum Make-up Torque = 36,100 (ft-lbs)
Operational Assembly Pipe Body Connection Max Operationa Assembly Pipe Body Connection
l Torque Max Tension Max Tension
Torque Max Tension Max Tension Tension Max Tension
(ft-lbs) (lbs) (lbs) (lbs) (ft-lbs) (lbs) (lbs) (lbs)
Connection
Make-up Torque Range
Make-up Torque Connection Max
(ft-lbs) Tension (lbs)
Min MUT 36,100 1,202,500
36,900 1,229,200
37,700 1,243,600
38,400 1,218,100
39,200 1,189,000
40,000 1,159,800
40,800 1,130,700
41,500 1,105,200
42,300 1,076,100
Max MUT 43,100 1,046,900
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box ID’s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
Connection
Wear
Tool Connection Max Connection Max Min MUT Connection Max
Torsional Tension Tension
New OD Joint OD MUT
(in) Strength (ft-lbs) (ft-lbs) (lbs) (ft-lbs) (lbs)
Pipe Body
Combined Loading Table (Torque-Tension)
Pipe Body 95 % Inspection Class Pipe Body OD (in) 5 Wall Thickness (in) 0.362 Pipe Body Grade S-135
Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box ID’s, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.
5.000
3.500 .362
18° 35°
4.000
6.625 3.250 4.875 4.276 6.625 3.250
Min.
UNLESS OTHERWISE
SPECIFIED 5in. 0.362 in - 19.5 lb/ft
ALL DIMENSIONS IEU - 5.125 Max OD
Range 2 S-135
ARE NOMINAL GPDS50, 6.625in. OD
Copyrighted as an unpublished work. ALL RIGHTS DRAWN BY 6.625in. Pin ID x 9in. Pin Tong
RESERVED. This work contains the CONFIDENTIAL AND Brian Narjes 6.625in. Box ID x 12in. Box Tong
PROPRIETARY INFORMATION of Grant Prideco. Neither DRAWING STATE DATE Arnco 350XT hardbanding applied 3/32in. Raised to tool joint OD.
this document nor any information disclosed here in shall be
reproduced in any form, used or disclosed to others for any
Uncontrolled 6/18/2015
2015-3391-2 6:53 AM
REFERENCED QUOTE SCALE DWG NO. SHEET REV
purpose including manufacturing without the express written
permission of Grant Prideco. 2015-3391 A NONE 1 of 1 1
Certificate of Make and Break
This hereby certifies that the Make and Break Operation has been
performed on the following:
GPDS50 PIN 6.625" OD X 3.25" ID 9" TONG SPACE WITH Arnco 350XT
HARDBANDING & WITH SE None & WITH H-Series BENCHMARKS
GPDS50 BOX 6.625" OD X 3.25" ID 12" TONG SPACE WITH Arnco 350XT
HARDBANDING & WITH SE None & WITH H-Series BENCHMARKS
5" OD 19.5 LB./FT. .362 WT IEU UPSET Range 2 GRADE S-135 DRILL STRING
WITH GPDS50 6.063 Bevel PIN 6.625" OD X 3.25" ID 9" TONG SPACE WITH Arnco
350XT HARDBANDING & WITH SE None & WITH H-Series BENCHMARKS AND
GPDS50 6.063 Bevel BOX 6.625" OD X 3.25" ID 12" TONG SPACE WITH Arnco
350XT HARDBANDING & WITH SE None & WITH H-Series BENCHMARKS, TK-34
COATING
10/13/2015
NOV Grant Prideco Representative Date
Pipe Size Pipe Weight Nominal Wall Grade Range Upset Type
5" 19.50# .362" S-135 II IEU
The above inspections were performed to meet or exceed the lateset revisions of the
following referenced specification, Tuboscope standard operating procedures, and
any applicable customer specifications:
TUBOSCOPE SOP: I-001, I-002, I-401, I-610 Rev. 6 & API 5DP
10/14/15