GT15 General Description
GT15 General Description
General Description
GT1595-XTBA GT1575V-STBA GT1575-VNBA
GT1595-XTBD GT1575V-STBD GT1575-VNBD
GT1585V-STBA GT1575-STBA GT1572-VNBA
GT1585V-STBD GT1575-STBD GT1572-VNBD
GT1585-STBA GT1575-VTBA GT1562-VNBA
GT1585-STBD GT1575-VTBD GT1562-VNBD
GT1565-VTBA GT1555-VTBD
GT1565-VTBD GT1555-QTBD
GT1555-QSBD
GT1550-QLBD
Thank you for purchasing the GOT1000 Series.
Prior to use, please read both this manual and detailed manual
thoroughly to fully understand the product.
MODEL GT15-U(HW)
MODEL
1D7M38
CODE
IB(NA)-0800322-L(0707)MEE
SAFETY PRECAUTIONS
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant manuals
introduced in this manual carefully and pay full attention to safety to handle the
product correctly.
The precautions given in this manual are concerned with this product.
In this manual, the safety precautions are ranked as "DANGER" and "CAUTION".
Note that the caution level may lead to a serious accident according to the
circumstances.
Always follow the instructions of both levels because they are important to
personal safety.
Please save this manual to make it accessible when required and always forward
it to the end user.
A-1
[DESIGN PRECAUTIONS]
DANGER
z Some failures of the GOT, communication unit or cable may keep the outputs
on or off.
An external monitoring circuit should be provided to check for output signals
which may lead to a serious accident.
Not doing so can cause an accident due to false output or malfunction.
z Do not use the GOT as the warning device that may cause a serious accident.
An independent and redundant hardware or mechanical interlock is required
to configure the device that displays and outputs serious warning.
Failure to observe this instruction may result in an accident due to incorrect
output or malfunction.
z Incorrect operation of the touch switch(s) may lead to a serious accident if the
GOT backlight is gone out.
When the GOT backlight goes out, the POWER LED flickers (green/orange)
and the display section turns black and causes the monitor screen to appear
blank, while the input of the touch switch(s) remains active.
This may confuse an operator in thinking that the GOT is in “screensaver”
mode, who then tries to release the GOT from this mode by touching the
display section, which may cause a touch switch to operate.
Note that the following occurs on the GOT when the backlight goes out.
• The POWER LED flickers (green/orange) and the monitor screen appears
blank
A-2
[DESIGN PRECAUTIONS]
DANGER
z The display section of the GT1595-X is an analog-resistive type touch panel.
If you touch the display section simultaneously in 2 points or more, the switch
that is located around the center of the touched point, if any, may operate.
Do not touch the display section in 2 points or more simultaneously.
Doing so may cause an accident due to incorrect output or malfunction.
CAUTION
z Do not bundle the control and communication cables with main-circuit, power
or other wiring.
Run the above cables separately from such wiring and keep them a minimum
of 100mm apart.
Not doing so noise can cause a malfunction.
z Do not press the GOT display section with a pointed material as a pen or
driver.
Doing so can result in a damage or failure of the display section.
[MOUNTING PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the GOT main unit to/from the panel.
Not doing so can cause the unit to fail or malfunction.
z Be sure to shut off all phases of the external power supply used by the system
before mounting or removing the communication unit, option function board or
multi-color display board onto/from the GOT.
Not doing so can cause the unit to fail or malfunction.
z When installing the multi-color display board, wear an earth band etc. to avoid
the static electricity.
Not doing so can cause a unit corruption.
A-3
[MOUNTING PRECAUTIONS]
CAUTION
z Use the GOT in the environment that satisfies the general specifications
described in this manual.
Not doing so can cause an electric shock, fire, malfunction or product damage
or deterioration.
z When mounting the GOT to the control panel, tighten the mounting screws in
the specified torque range.
Undertightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, short circuit or malfunction due to the
damage of the screws or the GOT.
z When loading the communication unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the specified torque
range.
Under tightening can cause the GOT to drop, short circuit or malfunction.
Overtightening can cause a drop, failure or malfunction due to the damage of
the screws or unit.
z When mounting the multi-color display board onto the GOT, tighten the
mounting screws within the specified torque range.
Loose tightening may cause the unit and/or GOT to malfunction due to poor
contact.
Overtightening may damage the screws, unit and/or GOT; they might
malfunction.
z Push the option function board onto the corresponding connector until it
clicks, so that it will be secured firmly.
z Push the multi-color display board onto the corresponding connector so that it
will be secured firmly.
z When inserting a CF card into the GOT, push it into the insertion slot until the
CF card eject button will pop out.
Failure to do so may cause a malfunction due to poor contact.
A-4
[MOUNTING PRECAUTIONS]
CAUTION
z When removing a CF card from the GOT, make sure to support the CF card
by hand, as it may pop out.
Failure to do so may cause the CF card to drop from the GOT and break.
[WIRING PRECAUTIONS]
DANGER
z Be sure to shut off all phases of the external power supply used by the system
before wiring.
Failure to do so may result in an electric shock, product damage or
malfunctions.
CAUTION
z Always ground the FG terminal, LG terminal, and protective ground terminal
of the GOT power to the protective ground conductors dedicated to the GOT.
z Use applicable solderless terminals and tighten them with the specified
torque.
If any solderless spade terminal is used, it may be disconnected
when the terminal screw comes loose, resulting in failure.
z Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
A-5
[WIRING PRECAUTIONS]
CAUTION
z Tighten the terminal screws of the GOT power supply section in the specified
torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or the GOT.
z Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
z The module has an ingress prevention label on its top to prevent foreign
matter, such as wire offcuts, from entering the module during wiring.
Do not peel this label during wiring.
Before starting system operation, be sure to peel this label because of heat
dissipation.
z Plug the communication cable into the connector of the connected unit and
tighten the mounting and terminal screws in the specified torque range.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
DANGER
z Before performing the test operations of the user creation monitor screen
(such as turning ON or OFF bit device, changing the word device current
value, changing the settings or current values of the timer or counter, and
changing the buffer memory current value), read through the manual carefully
and make yourself familiar with the operation method.
During test operation, never change the data of the devices which are used to
perform significant operation for the system.
False output or malfunction can cause an accident.
A-6
[STARTUP/MAINTENANCE PRECAUTIONS]
DANGER
z When power is on, do not touch the terminals.
Doing so can cause an electric shock or malfunction.
z Before starting cleaning or terminal screw retightening, always switch off the
power externally in all phases.
Not switching the power off in all phases can cause a unit failure or
malfunction.
Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or unit.
A-7
[STARTUP/MAINTENANCE PRECAUTIONS]
CAUTION
z Do not disassemble or modify the unit.
Doing so can cause a failure, malfunction, injury or fire.
z Do not touch the conductive and electronic parts of the unit directly.
Doing so can cause a unit malfunction or failure.
z When unplugging the cable connected to the unit, do not hold and pull the
cable portion.
Doing so can cause the unit or cable to be damaged or can cause a
malfunction due to a cable connection fault.
z Do not drop the module or subject it to strong shock. A module damage may
result.
z Before touching the unit, always touch grounded metals, etc. to discharge
static electricity from human body, etc.
Not doing so can cause the unit to fail or malfunction.
DANGER
z Before changing the backlight, always switch off the GOT power externally in
all phases (when the GOT is connected to the bus, the PLC CPU power must
also be switched off externally in all phases) and remove the GOT from the
control panel.
Not switching the power off in all phases may cause an electric shock.
Not removing the unit from the control panel can cause injury due to a drop.
A-8
[BACKLIGHT CHANGING PRECAUTIONS]
CAUTION
z When replacing the backlight, use the gloves.
Otherwise, it may cause you to be injured.
z Start changing the backlight more than 5 minutes after switching the GOT
power off.
Not doing so can cause a burn due to the heat of the backlight.
[DISPOSAL PRECAUTIONS]
CAUTION
z When disposing of the product, handle it as industrial waste.
[TRANSPORTATION PRECAUTIONS]
CAUTION
z When transporting lithium batteries, make sure to treat them based on the
transport regulations.
(Refer to GT15 User’s Manual for details of the regurated models.)
z Make sure to transport the GOT main unit and/or relevant unit(s) in the
manner they will not be exposed to the impact exceeding the impact
resistance described in the general specifications of the GT15 User's Manual,
as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
A-9
REVISIONS
* The manual number is noted at the lower right of the top cover.
A-10
Print Date *Manual Number Revision
Aug., 2006 IB(NA)-0800322-G Partial corrections
Chapter 6
Partial additions
Section 4.3.1, 4.3.3, 4.3.4, 5.3
This manual confers no industrial property rights or any rights of any other kind, nor does it
confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any
problems involving industrial property rights which may occur as a result of using the contents
noted in this manual.
© 2005 MITSUBISHI ELECTRIC CORPORATION
A-11
CONTENTS
1. Features......................................................................................................... 1
2. Part Names .................................................................................................... 3
2.1 Part Names and Settings of the GT1595 ................................................. 3
2.2 Part Names and Settings of the GT1585 ................................................. 5
2.3 Part Names and Settings of the GT157 ................................................... 7
2.4 Part Names and Settings of the GT156 .................................................. 9
2.5 Part Names and Settings of the GT155 ................................................. 11
3. Specifications............................................................................................... 13
3.1 General Specifications ........................................................................... 13
3.2 Performance Specifications ................................................................... 15
3.2.1 GT1595-X ..................................................................................... 15
3.2.2 GT1585V-S, GT1585-S ................................................................ 18
3.2.3 GT1575V-S, GT1575-S, GT1575-V, GT1575-VN, GT1572-VN ... 21
3.2.4 GT1565-V, GT1562-VN ................................................................ 25
3.2.5 GT1555-V, GT1555-Q, GT1550-Q ............................................... 28
3.3 Power Supply Specifications ................................................................. 31
3.3.1 For GOTs powered from the 100 to 240VAC power supply ......... 32
3.3.2 For GOTs powered from the 24VDC power supply ...................... 33
3.4 External Dimensions .............................................................................. 35
4. EMC and Low Voltage Directive .................................................................. 40
5. Installation.................................................................................................... 41
5.1 Control Panel Inside Dimensions for Mounting GOT ............................ 41
5.2 Panel Cutting Dimensions ..................................................................... 41
5.3 Mounting Position .................................................................................. 42
5.4 Control Panel Inside Temperature and Mounting Angle ........................ 45
5.5 Installation Procedure ............................................................................ 46
6. Wiring........................................................................................................... 47
6.1 Wiring Precautions ................................................................................ 47
6.2 Power Supply Wiring ............................................................................. 49
6.3 Wiring to GOT Power Section ............................................................... 50
6.4 Grouding ................................................................................................ 51
6.4.1 Grounding the GOT ...................................................................... 51
6.4.2 Wiring-related malfunction causes and the measures examples . 55
6.5 Panel Inside Wiring, Panel Outside Wiring ............................................ 59
6.5.1 Panel inside wiring ........................................................................ 59
A-12
6.5.2 Panel outside wiring ..................................................................... 60
6.6 Attaching Surge Suppressor for Control Equipment ............................. 61
6.7 Wiring FG Cable of Bus Connection Cable ........................................... 62
6.7.1 When connecting QCPU or motion controller CPU (Q series) to the
GOT ............................................................................................. 62
6.7.2 When connecting QnACPU, ACPU, or motion controller CPU (A
series) to the GOT ....................................................................... 62
7. Maintenance and Inspection........................................................................ 64
7.1 Daily Inspection ..................................................................................... 64
7.2 Periodic Inspection ................................................................................ 65
7.3 Battery Voltage Low Detection and Battery Replacement .................... 66
7.3.1 Applicable battery ......................................................................... 66
7.3.2 Battery specifications .................................................................... 66
7.3.3 Battery replacement procedure .................................................... 66
7.3.4 Battery life ..................................................................................... 67
Appendix. Confirming of Versions and Conformed Standards ........................ 68
A-13
Manuals
Detailed Manual
Manual Number
Manual name
(Type code)
GT15 User's Manual SH-080528ENG
(Option) (1D7M23)
Relevant Manual
For relevant manuals, refer to the PDF manual stored within the drawing
software used.
Product Components
The GOT product package includes the following:
GOT 1
GT1595-X
Installation fitting 8
GT1585V-S, GOT 1
GT1585-S,
GT1575V-S,
GT1575-S,
GT1575-V,
GT1575-VN,
GT1572-VN,
GT1565-V, Installation fitting 4
GT1562-VN,
GT1555-V,
GT1555-Q,
GT1550-Q
A-14
1.Features
1
(3) Enhanced support of FA device setup tools
• Transferring and monitoring sequence programs with the personal
computer connected to the GOT can be executed when
connecting to a PLC CPU with the direct CPU connection or bus
connection. (FA transparent function)
2
2.Part Names
16)
2),3)
1)
4)
14)
5)
6)
17)
8)
15)
9)
10)
11) 12)
3
No. Name Description
2) Display screen Displays the Utility and the user creation screen.
4
2.2 Part Names and Settings of the GT1585
17)
2),3)
1)
5)
15)
6) 7)
9)
16)
10)
11)
4)
12) 13)
5
No. Name Description
2) Display screen Displays the Utility and the user creation screen
For installing the video input unit, RGB input unit, video/RGB
4) Video/RGB interface*1
input unit, or RGB output unit
For connecting a personal computer
5) USB interface
(Connector type: MINI-B)
12) Optional function board For installing the optional function board
interface
Multi-color display board
13) For installing the multi-color display board
interface*2
6
2.3 Part Names and Settings of the GT157
2),3)
1)
5)
15)
6) 7)
9)
16)
10)
11)
4)
12) 13)
7
No. Name Description
2) Display screen Displays the Utility and the user creation screen
For installing the video input unit, RGB input unit, video/RGB
4) Video/RGB interface*1
input unit, or RGB output unit
For connecting a personal computer
5) USB interface
(Connector type: MINI-B)
8
2.4 Part Names and Settings of the GT156
2),3)
1)
4)
14)
5) 6)
8)
9)
10)
15)
11) 12)
9
No. Name Description
2) Display screen Displays the Utility and the user creation screen
10
2.5 Part Names and Settings of the GT155
8)
2),3)
1)
4) 13)
5) 14) 6)
9)
10)
12)
15)
11)
11
No. Name Description
2) Display screen Displays the Utility and the user creation screen
Protective ground
15) For earthing
terminal
12
3.Specifications
Item Specifications
Display
Operating 0 to 50°C
section
ambient
temperature Other than
*1 the display 0 to 55°C
section
Storage ambient
-20 to 60°C
temperature
Operating ambient
humidity 10 to 90% RH, non-condensing
*6
Storage ambient
10 to 90% RH, non-condensing
humidity*6
Half- Sweep
Frequency Acceleration
amplitude count
Compliant with JIS B3502 and IEC61131-2 (147 m/s2, 3 times each
Shock resistance
in X, Y and Z directions)
13
*1 When mounting an extension unit on the upper stage of
MELSECNET/H communication unit (GT15-J71LP23-25, GT15-
J71BR13) or CC-Link communication unit (GT15-J61BT13), the
operating ambient temperature must be reduced 5°C against the
maximum values described in general specifications.
*2 When using the MELSECNET/10 communication unit (GT15-
75J71LP23-Z, GT15-75J71BR13-Z) or CC-Link communication unit
(GT15-75J61BT13-Z), refer to the manual of the communication unit
you use. (Differs with the specification of GOT.)
*3 Do not use or store the GOT under pressure higher than the
atmospheric pressure of altitude 0m (0ft.). Failure to observe this
instruction may cause a malfunction.
*4 This indicates the section of the power supply to which the
equipment is assumed to be connected between the public electrical
power distribution network and the machinery within the premises.
Category II applies to equipment for which electrical power is
supplied from fixed facilities.
The surge voltage withstand level for up to the raged voltage of 300 V
is 2500 V.
*5 This index indicates the degree to which conductive material is
generated in the environment where the equipment is used.
In pollution degree 2, only non-conductive pollution occurs but
temporary conductivity may be produced due to condensation.
*6 The wet-bulb temperature is 39°C or less for STN LCDs.
14
3.2 Performance Specifications
The performance specifications of the GT15 is as follows.
3.2.1 GT1595-X
3.2.2 GT1585V-S, GT1585-S
3.2.3 GT1575V-S, GT1575-S, GT1575-V, GT1575-VN,
GT1572-VN
3.2.4 GT1565-V, GT1562-VN
3.2.5 GT1555-V, GT1555-Q, GT1550-Q
3.2.1 GT1595-X
Specifications
Item
GT1595-XTBA GT1595-XTBD
TFT color liquid crystal display (High intensity and wide angle
Type
view)
Screen size 15"
Resolution 1,024 768 dots
Display size 304.1(12.0)(W) 228.1(8.98)(H) [mm](inch)
16-dot standard font : 64 characters 48 lines (2byte character)
Display character
12-dot standard font : 85 characters 64 lines (2byte character)
Display
section Display color 65536 colors *2
*1
Left/Right: 75 degrees
Display angle Top : 50 degrees
Bottom : 60 degrees
Intensity of LCD
450 [cd/m²]
only
Intensity
8-level adjustment
adjustment
Life Approx. 52,000 h (Operating ambient temperature : 25°C)
Cold cathode fluorescent tube (replaceable) backlight shutoff
Backlight detection function is included
Backlight off/screen saving time can be set.
Approx. 50,000 h or longer
Life*3 (Time when display luminance reaches 50% at the operating
ambient temperature of 25°C)
Type Analog resistive film
Key size Minimum 2 2 dots (per key)
Touch Number of objects
panel that can be Simultaneous presses not allowed.
simultaneously (Only 1 point can be touched.)
touched
Life 1 million times or more (operating force 0.98N max.)
15
Specifications
Item
GT1595-XTBA GT1595-XTBD
Detection length 1(39.37) [m](inch)
Human Detection range Left/Right/Top/Bottom: 70 degrees
sensor Detection delay
0 to 4s
time
C drive Built-in flash memory 9Mbytes (for storing project data and OS)
Memory
*4 Life (Number of
100,000 times
write times)
Battery GT15-BAT lithium battery (Option)
Backup target Clock data and maintenance time notification data
Life Approx. 5 years (Operating ambiant temperature of 25°C)
RS-232, 1ch
Transmission speed : 115,200/57,600/38,400/19,200/9,600/
4,800 bps
RS-232*6 Connector shape : D-sub 9-pin (Male)
Application : For communicating with a controller or connecting a
personal computer (Project data upload/download, OS
installation, FA transparent function)
USB (Full Speed 12Mbps), Device, 1ch
Connector shape: Mini-B
USB
Built-in Application: For connecting a personal computer (Project data
interface upload/download, OS installation and FA transparent function))
Compact flash slot, 1ch
CF card Connector shape : TYPE I
Application : Data transfer, data storage
Option function
For option function board mounting, 1ch
board
Multi-color display
For multi-color display board mounting, 1ch
board
Extension unit*6 For communication unit/option unit mounting, 2ch
Buzzer output Single tone (tone length adjustable)
Outside the enclosure: IP67*5
Protective structure
Inside the enclosure: IP2X
External dimensions
(Excluding USB
397(15.6)(W) 296(11.7)(H) 61(2.40)(D)[mm](inch)
environmental protection
cover)
Panel cutting dimensions 383.5(15.1)(W) 282.5(11.1)(H)[mm](inch)
Weight 4.9kg (mounting fixtures are not included)
Compatible software
package 2.17T or later 2.30G or later
(GT Designer2 Version)
16
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid
crystal display panel due to its characteristics. It is impossible to
completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Please note that
these dots appear due to its characteristic and are not caused by
product defect.
*2 With the hardware version indicated below, it will be 256 colors when
the multi-color display board is not installed.
For how to confirm the function version, refer to the following.
Appendix Confirming of Versions and Conformed Standards
17
3.2.2 GT1585V-S, GT1585-S
Specifications
Item GT1585V- GT1585V-
GT1585-STBA GT1585-STBD
STBA STBD
TFT color liquid crystal display (High intensity and wide angle
Type
view)
Screen size 12.1”
Resolution 800 600 dots
Display size 246(9.69)(W) 184.5(7.26)(H) [mm](inch)
16-dot standard font : 50 characters 37 lines (2byte
characters)
Display character
12-dot standard font : 66 characters 50 lines (2byte
Display characters)
section
*1 Display color 65536 colors *2
Left/Right: 60 degrees Left/Right: 65 degrees
Display angle Top : 40 degrees Top : 45 degrees
Bottom : 50 degrees Bottom : 55 degrees
Intensity of LCD
350 [cd/m2] 400 [cd/m2]
only
Intensity
8-level adjustment
adjustment
Life Approx. 50,000 h (Operating ambient temperature : 25°C)
Cold cathode fluorescent tube (replaceable) backlight shutoff
Backlight detection function is included.
Backlight off/screen saving time can be set.
Approx. 50,000 h or longer
Life*3 (Time when display luminance reaches 50% at the operating
ambient temperature of 25°C)
Type Matrix resistive film
Number of touch 1,900 objects/screen
keys (38 lines 50 columns)
Minimum 16 16 dots (16 8 dots for the last line only) (per
Key size
Touch key)
panel Number of objects
that can be
Maximum of 2 objects
simultaneously
touched
Life 1 million times or more (operating force 0.98N max.)
Detection length 1(39.37) [m](inch)
Human Detection range Left/Right/Top/Bottom: 70 degrees
Sensor Detection delay
0 to 4s
time
18
Specifications
Item GT1585V- GT1585V-
GT1585-STBA GT1585-STBD
STBA STBD
C drive Built-in flash memory 9Mbytes (for storing project data and OS)
Memory
*4 Life (Number
100,000 times
of write times)
Battery GT15-BAT lithium battery (Option)
Backup target Clock data and maintenance time notification data
Life Approx. 5 years (Operating ambient temperature of 25°C)
RS-232, 1ch
Transmission speed:115,200/57,600/38,400/19,200/9,600/4,800
bps
RS-232*6 Connector shape:D-sub 9-pin (Male)
Application:For communicating with a controller or connecting a
personal computer (Project data upload/download, OS
installation, FA transparent function)
USB (Full Speed 12Mbps), Device, 1ch
Connector shape:Mini-B
USB
Built-in Application:For connecting a Personal computer (Project data
interface upload/download, OS installation and FA transparent function)
Compact flash slot, 1ch
CF card Connector shape:TYPE I
Application:Data transfer, data storage
Option function
For option function board mounting, 1ch
board
Multi-color
For multi-color display board mounting, 1ch
display board
Extension unit*6 For communication unit/option unit mounting, 2ch
Buzzer output Single tone (tone length adjustable)
Outside the enclosure: IP67 *5
Protective structure
Inside the enclosure: IP2X
External dimensions
(Excluding USB
316(12.44)(W) × 242(9.53)(H) × 52(2.05)(D) [mm](inch)
environmental protection
cover)
Panel cutting dimensions 302(11.89)(W) × 228(8.98)(H)[mm](inch)
Weight 2.8 kg (mounting fixtures are not included)
Compatible software
package 2.30G or later 2.04E or later 2.17T or later
(GT Designer2 Version)
19
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid
crystal display panel due to its characteristics. It is impossible to
completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Please note that
these dots appear due to its characteristic and are not caused by
product defect.
*2 With the hardware version indicated below, it will be 256 colors when
the multi-color display board is not installed.
For how to confirm the function version, refer to the following.
Appendix Confirming of Versions and Conformed Standards
20
3.2.3 GT1575V-S, GT1575-S, GT1575-V, GT1575-VN,
GT1572-VN
Specifications
GT1575-VNBA,
Item GT1575V-STBA, GT1575-STBA, GT1575-VTBA, GT1575-VNBD,
GT1575V-STBD GT1575-STBD GT1575-VTBD GT1572-VNBA,
GT1572-VNBD
TFT color liquid crystal (LCD of high intensity and TFT color liquid
Type
wide angle view) crystal
Screen size 10.4"
Resolution 800 600dots 640 480dots
Display size 211(8.31)(W) 158(6.22)(H)[mm](inch)
16-dot standard font: 16-dot standard font:40
50 characters 37 lines characters 30 lines
Display (2byte characters) (2byte characters)
character 12-dot standard font: 12-dot standard font:53
66 characters 50 lines characters 40 lines
(2byte characters) (2byte characters)
GT1575-VN:
Display 256color
section Display color 65536color*2
GT1572-VN:
*1
16color
Left/Right:45
Left/ Right/Top/ degrees
Display Left/Right/Top/Bottom:
Bottom: Top:30 degrees
angle 85 degrees
85 degrees Bottom:20
degrees
Intensity of
400[cd/m2] 380[cd/m2] 200[cd/m2]
LCD only
Intensity 4-level
8-level adjustment
adjustment adjustment
Approx. 50,000 h
Approx. 41,000 h (Operating
Life (Operating ambient temparature:
ambient temparature:25°C)
25°C)
Cold cathode fluorescent tube (replaceable) backlight shutoff
Backlight detection function is included.
Backlight off/screen saving time can be set.
Approx. 40,000 h or longer (Time when display luminance reaches
Life*3
50% at the operating ambient temperature of 25°C )
Type Matrix resistive film
Number of 1,900 objects/screen 1,200 objects/screen (30 lines
Touch
touch keys (38 lines 50 columns) 40 columns)
panel
Minimum 16 16 dots (16 8
Key size Minimum 16 16 dots (per key)
dots for the last line only)(per key)
21
Specifications
GT1575-VNBA,
Item GT1575V-STBA, GT1575-STBA, GT1575-VTBA, GT1575-VNBD,
GT1575V-STBD GT1575-STBD GT1575-VTBD GT1572-VNBA,
GT1572-VNBD
Number of
objects that
Touch can be Maximum of 2 objects
panel simultaneou
sly touched
Life 1 million times or more (operating force 0.98 max.)
Detection
None
length
Human Detection
None
sensor range
Detection
None
delay time
Built-in flash
memory
Built-in flash memory 9Mbytes 5Mbytes
C drive
(for storing project data and OS) (for storing
Memory project data
*4
and OS)
Life
(Number of 100,000 times
write times)
Batery GT15-BAT lithium battery (Option)
Backup
Clock data and maintenance time notification data
target
Life Approx. 5 years (Operating ambient temperature of 25°C)
RS-232, 1ch
Transmission speed:115,200/57,600/38,400/19,200/9,600/4,800 bps
Connector shape:D-sub 9-pin (Male)
RS-232*6
Application:For communicating with a controller or connecting a
personal computer (Project data upload/download, OS installation,
FA transparent function)
USB (Full Speed 12 Mbps), Device, 1ch
Built-in Connector shape:Mini-B
USB
interface Application:For connecting a personal computer (Project data upload/
download, OS installation and FA transparent function)
Compact flash slot, 1ch
CF card Connector shape: TYPE I
Application: Data transfer, data storage
Option
function For option function board mounting, 1ch
board
(Continued to next page)
22
Specifications
GT1575-VNBA,
Item GT1575V-STBA, GT1575-STBA, GT1575-VTBA, GT1575-VNBD,
GT1575V-STBD GT1575-STBD GT1575-VTBD GT1572-VNBA,
GT1572-VNBD
Cannot be
Multi-color used. (Even
display For multi-color display board mounting, 1ch installed, 65536
Built-in board colors will not
interface be displayed.)
Extension
For communication unit/option unit mounting, 2ch
unit*6
Buzzer output Single tone (tone length adjustable)
Outside the enclosure: IP67*5
Protective structure
Inside the enclosure: IP2X
External dimensions
(Excluding USB
303(11.93)(W) 214(8.43)(H) 49(1.93)(D)[mm](inch)
environmental
protective cover)
Panel cutting
289(11.38)(W)×200(7.87)(H)[mm](inch)
dimensions
2.3 kg 2.3 kg
2.4 kg
(mounting (mounting
Weight (mounting fixtures are not
fixtures are not fixtures are not
included)
included) included)
Compatible software GT1575-STBA: GT1575-VTBA:
package 2.04E or later 2.04E or later
2.30G or later 2.17T or later
(GT Designer2 GT1575-STBD: GT1575-VTBD:
Version) 2.17T or later 2.17T or later
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid
crystal display panel due to its characteristics. It is impossible to
completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Please note that
these dots appear due to its characteristic and are not caused by
product defect.
23
*2 With the hardware version indicated below, it will be 256 colors when
the multi-color display board is not installed.
For how to confirm the function version, refer to the following.
Appendix Confirming of Versions and Conformed Standards
Item Model Function version
GT1575-STBA A
GT1575-STBD A
GT1575
GT1575-VTBA A
GT1575-VTBD A
24
3.2.4 GT1565-V, GT1562-VN
Specifications
Item GT1565-VTBA, GT1562-VNBA,
GT1565-VTBD GT1562-VNBD
TFT color liquid crystal (LCD of
Type high intensity and wide angle TFT color liquid crystal
view)
Screen size 8.4"
Resolution 640×480dots
Display size 171(6.73)(W) 128(5.04)(H)[mm](inch)
16-dot standard font: 40 characters × 30 lines (2byte characters)
Display character
Display 12-dot standard font: 53 characters × 40 lines (2byte characters)
section Display color 65536color*2 16color
*1
Left/Right: 65 degrees Left/Right: 45 degrees
Display angle Top : 50 degrees Top : 20 degrees
Bottom : 60 degrees Bottom : 20 degrees
Intensity of LCD
380[cd/m2] 150[cd/m2]
only
Intensity
8-level adjustment 4-level adjustment
adjustment
Life Approx. 41,000 h (Operating ambient temperature: 25°C)
Cold cathode fluorescent tube (replaceable) backlight shutoff
Backlight detection function is included.
Backlight off/screen saving time can be set.
Approx. 40,000 h or longer
Life*3 (Time when display luminance reaches 50% at the operating
ambient temperature of 25°C)
Type Matrix resistive film
Number of touch
1,200 objects/screen (30 lines 40 columns)
keys
Key size Minimum 16 16 dots (per key)
Touch
panel Number of objects
that can be
Maximum of 2 objects
simultaneously
touched
Life 1 million times or more (operating force 0.98N max.)
Detection length None
Human Detection range None
sensor Detection delay
None
time
25
Specifications
Item GT1565-VTBA, GT1562-VNBA,
GT1565-VTBD GT1562-VNBD
Built-in flash memory 9Mbytes Built-in flash memory 5Mbytes
C drive
Memory (for string project data and OS) (for string project data and OS)
*4
Life (Number of
100,000 times
write times)
Battery GT-15BAT lithium battery (Option)
Backup target Clock data and maintenance time notification data
Life Approx. 5 years (Operating ambient temperature of 25°C)
RS-232, 1ch
Transmission speed:115,200/57,600/38,400/19,200/9,600/4,800
bps
RS-232*6 Connector shape:D-sub 9-pin (Male)
Application: For communicating with a controller or connecting a
personal computer (Project data upload/download, OS
installation and FA transparent function)
USB (Full Speed 12 Mbps), Device, 1ch
Connector shape:Mini-B
Built-in USB
Application:For connecting a personal computer (Project data
interface upload/download, OS installation and FA transparent function)
Compact flash slot, 1ch
CF card Connector shape: TYPE I
Application: Data transfer, data storage
Option function
For option function board mounting, 1ch
board
Cannot be used. (Even
Multi-color display For multi-color display board
installed, 65536 colors will not
board mounting, 1ch
be displayed.)
Built-in
Extension unit*6 For communication unit/option unit mounting, 2ch
interface
Buzzer output Single tone (tone length adjustable)
Outside the enclosure: IP67*5
Protective structure
Inside the enclosure: IP2X
External dimensions
(Excluding USB
241(9.49)(W) 190(7.48)(H) 52(2.05)(D)[mm](inch)
environmental protective
cover)
Panel cutting dimensions 227(8.94)(W) 176(6.93)(H)[mm](inch)
Weight 1.9 kg (mounting fixtures are not included)
Compatible software
GT1565-VTBA:2.04E or later,
package 2.17T or later
GT1565-VTBD:2.17T or later
(GT Designer2 Version)
26
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid
crystal display panel due to its characteristics. It is impossible to
completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Please note that
these dots appear due to its characteristic and are not caused by
product defect.
*2 With the hardware version indicated below, it will be 256 colors when
the multi-color display board is not installed.
For how to confirm the function version, refer to the following.
Appendix Confirming of Versions and Conformed Standards
Item Model Function version
GT1565-VTBA A
GT1565
GT1565-VTBD A
27
3.2.5 GT1555-V, GT1555-Q, GT1550-Q
Specifications
Item GT1555- GT1555- GT1555- GT1550-
VTBD QTBD QSBD QLBD
TFT color liquid crystal (LCD of STN
STN color
Type high intensity and wide angle monochrome
liquid crystal
view) liquid crystal
Screen size 5.7"
Resolution 640×480dots 320 240dots
Display size 115(4.53)(W)×86(3.39)(H)[mm](inch)
16-dot
standard font:
40 characters
30 lines
(2byte 16-dot standard font: 20 characters 15 lines
characters) (2byte characters)
Display character
12-dot 12-dot standard font: 26 characters 20 lines
standard font: (2byte characters)
53 characters
Display 40 lines
section (2byte
*1 characters)
monochrome
Display color 65536color*2 4096color
(16-level)
Left/Right: Left/Right: Left/Right: Left/Right:
80 degrees 70 degrees 55 degrees 45 degrees
Top: Top: Top: Top:
Display angle
80 degrees 70 degrees 65 degrees 20 degrees
Bottom: Bottom: Bottom: Bottom:
70 degrees 50 degrees 70 degrees 40 degrees
Intensity of LCD
350[cd/m2] 400[cd/m2] 380[cd/m2] 220[cd/m2]
only
Intensity
8-level adjustment
adjustment
Contrast
None 16-level adjustment
adjustment
Life Approx. 50,000 h (Operating ambient temperature: 25°C)
28
Specifications
Item GT1555- GT1555- GT1555- GT1550-
VTBD QTBD QSBD QLBD
Cold cathode fluorescent tube (nonreplaceable) backlight shutoff
Backlight detection function is included.
Backlight off/screen saving time can be set.
Approx.
58,000 h or
longer
(Time when
display
Approx. 75,000 h or longer
luminance
Life*2 (Time when display luminance reaches 50% at
reaches 50%
the operating ambient temperature of 25°C)
at the
operating
ambient
temperature of
25°C)
Type Matrix resistive film
1200 objects/
screen (Matrix
Touch Number of touch 300 objects/screen (Matrix structure of 15 lines
structure of 30
panel keys 20 columns)
lines 40
columns)
Key size Minimum 16 16 dots (per key)
Number of
objects that can
Touch be Maximum of 2 objects
panel simultaneously
*6
touched
Life 1 million times or more (operating force 0.98N max.)
Detection length None
Human Detection range None
sensor Detection delay
None
time
Built-in flash memory 9Mbytes
C drive
Memory (for string project data and OS)
*3
Life (Number of
100,000 times
write times)
Battery GT15-BAT lithium battery (Option)
Backup target Clock data and maintenance time notification data
Life Approx. 5 years (Operating ambient temperature of 25°C)
(Continued to next page)
29
Specifications
Item GT1555- GT1555- GT1555- GT1550-
VTBD QTBD QSBD QLBD
RS-232, 1ch
Transmission speed:115,200/57,600/38,400/19,200/9,600/
4,800 bps
RS-232*5 Connector shape:D-sub 9-pin (Male)
Application: For communicating with a controller or connecting a
personal computer (Project data upload/download, OS
installation and FA transparent function)
USB (Full Speed 12 Mbps), Device, 1ch
Built-in Connector shape:Mini-B
interface USB Application:For connecting a personal computer (Project data
upload/download, OS installation and FA transparent function)
Compact flash slot, 1ch
CF card Connector shape: TYPE I
Application: Data transfer, data storage
Option function
For option function board mounting, 1ch
board
Extension unit*5 For communication unit/option unit mounting, 1ch
Buzzer output Single tone (tone length adjustable)
Outside the enclosure: IP67*4
Protective structure
Inside the enclosure: IP2X
External dimensions
(Excluding USB
167(6.6)(W)×135(5.3)(H)×56(2.2)(D)[mm](inch)
environmental protective
cover)
Panel cutting dimensions 153(6.0)(W)×121(4.8)(H)[mm](inch)
Weight 1.1 kg (mounting fixtures are not included)
Compatible software
package 2.58L or later 2.32J or later
(GT Designer2 Version)
*1 Bright dots (always lit) and dark dots (unlit) may appear on a liquid
crystal display panel due to its characteristics. It is impossible to
completely avoid this symptom, as the liquid crystal display
comprises of a great number of display elements. Flickers may be
observed depending on the display color. Please note that these dots
and flickers appear due to its characteristic and are not caused by
product defect.
*2 The GOT screen saving/backlight off function prevents images from
becoming permanently etched on the display screen and increases
the backlight life.
*3 ROM in which new data can be written without deleting the written
data.
30
*4 Compliant with IP67 when the USB environmental protection cover is
attached. Compliant with IP2X at the USB interface only when a
USB cable is connected. Note that this does not guarantee all users'
operation environment.
*5 When using multiple extension units and a bar code reader, the total
current of the extension units and bar code reader must not be
greater than the total current that the GOT can supply.
For current values of extension units and bar code reader and the
total current that the GOT can supply, refer to the following manual.
GT Designer2 Version Screen Design Manual
*6 The GT1555-V can be operated with a stylus pen.
With a stylus pen, small-sized touch switches can be certainly
operated.
Use a stylus pen that satisfies the following specifications.
Material: Polyacetal resin Pen tip radius: 0.8mm or more
Remarks
31
3.3.1 For GOTs powered from the 100 to 240VAC power
supply
Specifications
GT1575V-STBA,
GT1575-STBA,
Item GT1575-VTBA,
GT1585V-STBA,
GT1595-XTBA GT1575-VNBA,
GT1585-STBA
GT1572-VNBA,
GT1565-VTBA,
GT1562-VNBA
Input power supply
100 to 240VAC (+10% -15%)
voltage
Input frequency 50/60Hz 5%
Input max. apparent
110VA (maximum load)
power
Power consumption 56W or less 41W or less 39W or less
At backlight off 30W or less 28W or less
50A or less (4ms) 45A or less (4ms) 40A or less (4ms)
Inrush current
(maximum load) (maximum load) (maximum load)
Permissible
instantaneous power 20ms or less (100VAC or more)
failure time
1,500Vp-p noise voltage, 1µs noise width (when measuring with a
Noise immunity
noise simulator under 25 to 60Hz noise frequency)
Dielectric withstand
1500VAC for 1 minute across power terminals and earth
voltage
10M or more across power terminals and earth by a 500VDC
Insulation resistance
insulation resistance tester
Applicable wire size 0.75 to 2 [mm2]
Applicable solderless Solderless terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A,
terminal FV2-N3A
Applicable tightening
torque (Terminal block 0.5 to 0.8 [N•m]
terminal screw)
32
3.3.2 For GOTs powered from the 24VDC power supply
Specifications
GT1575
V-STBD,
GT1575-
STBD,
GT1575-
GT1585 VTBD,
Item GT1595- V-STBD, GT1575- GT1555- GT1555- GT1555- GT1550-
XTBD GT1585- VNBD, V QTBD QSBD QLBD
STBD GT1572-
VNBD,
GT1565-
VTBD,
GT1562-
VNBD
Input power
24VDC (+25%, -20%)
supply voltage
57W or 43W or 41W or 19W or 18W or 17W or 15W or
Power less less less less less less less
consumption (2380mA (1790mA (1710mA (790mA/ (750mA/ (710mA/ (620mA/
/24VDC) /24VDC) /24VDC) 24VDC) 24VDC) 24VDC) 24VDC)
32W or 14W or
less 30W or less less
At backlight off 13W or less (540mA/24VDC)
(1330mA (1250mA/24VDC) (580mA/
/24VDC) 24VDC)
100A or 67A or
less 115A or less less
60A or less (1ms)(maximum
Inrush current (4ms) (1ms)(maximum (1ms)(m
load)
(maximu load) aximum
m load) load)
Permissible
instantaneous
10 ms or less
power failure
time
500Vp-p noise voltage, 1 s noise width (when measuring with a noise
Noise immunity
simulator under 25 to 60Hz noise frequency)
Dielectric
withstand 500VAC for 1 minute across power terminals and earth
voltage
Insulation 10M or more across power terminals and earth by a 500VDC insulation
resistance resistance tester
Applicable wire
0.75 to 2 [mm²]
size
Applicable
solderless Solderess terminal for M3 screw RAV1.25-3, V2-S3.3, V2-N3A, FV2-N3A
terminal
33
Specifications
GT1575
V-STBD,
GT1575-
STBD,
GT1575-
GT1585 VTBD,
Item GT1595- V-STBD, GT1575- GT1555- GT1555- GT1555- GT1550-
XTBD GT1585- VNBD, V QTBD QSBD QLBD
STBD GT1572-
VNBD,
GT1565-
VTBD,
GT1562-
VNBD
Applicable
tightening torque
0.5 to 0.8 [N•m]
(Terminal block
terminal screw)
34
3.4 External Dimensions
(1) GT1595
397(15.6)
(0.39)
10
320(12.6)
296(11.7)
281(11.1)
(0.39)
320(12.6)
10
(0.20)
5
(0.24)
6
(2.4)
61
382(15.0)
Unit:mm(inch)
35
(2) GT1585
316(12.44)
263(10.35)
(0.39)
10
227(8.94)
242(9.53)
(0.39)
10
250(9.84)
(0.20)
5
(0.24)
(2.05)
(2.20)
6
52
56
301(11.85)
Unit: mm (inch)
36
(3) GT157
303 (11.93)
252 (9.92)
(0.39)
10
199 (7.83)
214 (8.43)
(0.39)
10
222 (8.74)
(0.20)
5
(0.24)
(1.93)
(2.20)
49
6
56
288 (11.34)
Unit: mm (inch)
37
(4) GT156
241 (9.49)
175.5 (6.91)
(0.39)
10
175 (6.89)
190 (7.48)
(0.39)
10
175.5 (6.91)
(0.20)
5
52 (2.05)
56 (2.20)
(0.24)
6
226 (8.90)
Unit: mm (inch)
38
(5) GT155
167 (6.58)
10 (0.39)
110 (4.33)
120 (4.73)
135 (5.32)
10 (0.39)
110 (4.33)
5 (0.20)
60 (2.36)
6 (0.24)
152 (5.99)
Unit: mm (inch)
39
4.EMC and Low Voltage Directive
For the products sold in European countries, the conformance to the EMC
Directive, which is one of the European Directives, has been a legal obligation
since 1996.
Also, conformance to the Low Voltage Directive, another European Directives, has
been a legal obligation since 1997.
Manufacturers who recognize their products must conform to the EMC and Low
Voltage Directive are required to declare that their products conform to these
Directives and put a "CE mark" on their products.
When manufacturers produce machineries using the GOT, they should finally
decide the EMC and low voltage directives conformance method or judge if the
manufactured machineries conform to these directives.
For the EMC and low voltage directives conformance method for the GOT1000
series, refer to the GT15 User’s Manual.
The above manual can be downloaded from the Information site for Mitsubishi
industrial automation products MELFANSweb website.
Also, conformance to the EMC Directive of the GOT1000 series can be confirmed
with the MELFANSweb website.
For latest information, please confirm on the MELFANSweb website.
(MELFANSweb website: http://wwwf2.mitsubishielectric.co.jp/english/index.html)
40
5.Installation
POINT
Applicable cable
Some cables may need to be longer than the specified dimensions
when connecting to the GOT.
Therefore, consider the connector dimensions and bending radius of
the cable as well for installation.
A
B
+2(0.08) +2(0.08)
GT1585 302(11.89) 0(0) 228(8.98) 0(0)
+2(0.08) +2(0.08)
GT157 289(11.38) 0(0) 200(7.87) 0(0)
+2(0.08) +2(0.08)
GT156 227(8.94) 0(0) 176(6.93) 0(0)
+2(0.08) +2(0.08)
GT155 153(6.02) 0(0) 121(5) 0(0)
41
5.3 Mounting Position
When mounting the GOT, the following clearances must be left from
the other device.
B
C D E
A
50 (1.97)
Ethernet communication unit is 50 (1.97) or more or more
fitted [20 (0.79) or more] [40 (1.58)
or more]
MELSECNET/10 communication 50 (1.97) or more
—
unit (coaxial) is fitted [20 (0.79) or more]
CC-Link communication unit 50 (1.97) or more
—
(GT15-75J61BT13-Z) fitted [20 (0.79) or more]
50(1.97)
CC-Link communication 50 (1.97) or more or more
unit (GT15-J61BT13) fitted [20 (0.79) or more] [32(1.26)
or more]
(Continued to next page)
42
Type GT1595 GT1585 GT157 GT156 GT155
50(1.97) 50(1.97) 50(1.97) 50(1.97)
MELSECNET/10 communication or more or more or more or more
—
unit (optical) fitted [20(0.79) [26(1.02) [43(1.69) [48(1.89)
or more] or more] or more] or more]
50(1.97) 50(1.97) 50(1.97)
MELSECNET/H communication or more or more or more 50(1.97) 72(2.84)
unit (coaxial) fitted [20(0.79) [24(0.95) [38(1.5) or more or more
or more] or more] or more]
MELSECNET/H communication
50 (1.97) or more [20 (0.79) or more]*1
unit (optical) fitted
50(1.97) 50(1.97)
50(1.97) or more or more or more 50(1.97)
printer unit fitted
[20(0.79) or more] [31(1.22) [36(1.47) or more
or more] or more]
50 (1.97) or more
Video input unit fitted — — —
[20 (0.79) or more]*2
50 (1.97) or more
RGB input unit fitted — — —
[20 (0.79) or more]*3
A Video/RGB input unit fitted 50 (1.97) or more
— — —
[20 (0.79) or more]*3
50 (1.97) or more
RGB output unit fitted — — —
[20 (0.79) or more]*3
50 (1.97) 50 (1.97)
50 (1.97) or more or more or more 65(2.56)
CF card unit
[20 (0.79) or more] [31 (1.22) [36 (1.47) or more
or more] or more]
50 (1.97) 50 (1.97)
50 (1.97) or more or more or more 65(2.56)
CF card extension unit
[20 (0.79) or more] [31 (1.22) [36 (1.47) or more
or more] or more]
50 (1.97) 50 (1.97)
50 (1.97) or more or more or more 65(2.56)
Output/Input unit
[20 (0.79) or more] [31 (1.22) [36 (1.47) or more
or more] or more]
50 (1.97) 50 (1.97)
50 (1.97) or more or more or more 65(2.56)
Sound Interface Unit
[20 (0.79) or more] [31 (1.22) [36 (1.47) or more
or more] or more]
80(3.15) or more
B
[20(0.79) or more]
(When the CF card is not used) 50(1.97) or more [20(0.79) or more]
C 100(3.94)
(When the CF card is used) 50(1.97) or more [20(0.79) or more]
or more
(Continued to next page)
43
Type GT1595 GT1585 GT157 GT156 GT155
50(19.7) or more
D
[20(0.79) or more]
100(39.4) or more
E
[20(0.79) or more]
Unit: mm (inch)
*1 This value differs depending on the cable used.
Please contact your local Mitsubishi (Electric System) Service.
The value indicated in the table is a reference value.
*2 This value is for use of the coaxial cable 3C-2V (JIS C 3501).
MODEL GT15V-75V4R1 Video/RGB Input Unit MODEL
GT15V-75V4 Video Input Unit MODEL GT15V-75R1 RGB
Input Unit User's Manual (Section 2.4.1 Specifications of the
cables (coaxial cables) used when displaying video images)
*3 This value differs depending on the cable used.
If the bending radius of the cable used is greater than the value
specified above, apply the value of the cable used.
44
5.4 Control Panel Inside Temperature and Mounting Angle
When mounting the main unit to a control panel or similar, set the
display section as shown below.
• When the temperature inside the control panel is 40 to 55°C or
less, the mounting angle should be in the range 60 to 105
degrees.
GOT
105
Display
section 60
Control panel,
etc.
45
5.5 Installation Procedure
The GOT mounting procedure is as follows.
For the panel cutting dimensions of each GOT, refer to the following.
5.2 Panel Cutting Dimensions
(1) Insert the GOT into the panel opening from the front side.
GOT
Mounting hole
(2) Place the mounting fixtures (included with GOT) on the mounting
fixture attaching part of the GOT, and fix them by tightening the
mounting screws in the torque range of 0.36 to 0.48N·m.
(Failure to do so may distort the panel and make a surface waviness
on the protective sheet.)
Magnified figure Magnified figure
• For GT1595-X: Fix the GOT with 8 • For other than GT1595-X: Fix the
mounting fixtures. GOT with 4 mounting fixtures.
46
6.Wiring
DANGER
z Before starting wiring, always switch off the GOT power externally in all
phases.
Not doing so may cause an electric shock, product damage or malfunction.
CAUTION
z Please make sure to ground FG terminal and LG terminal of the GOT power
supply section by applying Class D Grounding (Class 3 Grounding Method) or
higher which is used exclusively for the GOT.
Not doing so may cause an electric shock or malfunction.
z Correctly wire the GOT power supply section after confirming the rated
voltage and terminal arrangement of the product.
Not doing so can cause a fire or failure.
z Tighten the terminal screws of the GOT power supply section in the specified
torque range. Undertightening can cause a short circuit or malfunction.
Overtightening can cause a short circuit or malfunction due to the damage of
the screws or the GOT.
z Exercise care to avoid foreign matter such as chips and wire offcuts entering
the GOT. Not doing so can cause a fire, failure or malfunction.
47
Remarks
General preventive measures against noise
There are two kinds of noises: Radiated noise that is transmitted into the air
and Conductive noise that is directly transmitted along connected lines.
Countermeasures must be taken considering both kinds of noises and
referring to the following 3 points.
48
6.2 Power Supply Wiring
• Make wiring connections to the power supply, I/O equipment and
power equipment separately by system as shown below.
When frequent noise is identified, connect an isolation
transformer.
Isolation
Main power GOT power transformer
GOT
T1
I/O power
I/O equipment
GOT
AC I/O equipment
E2
49
POINT
1. Separate the grounding of the lightning surge absorber (E1) from
the grounding of the GOT (E2).
100/110V AC
AC In the case of 100V AC
GOT
Fuse
INPUT
100-240VAC
AD (LG) (FG)
DC
24V DC
INPUT
24VDC
- +
(LG) (FG)
GOT
INPUT
24VDC
- +
(FG)
Ground cables
Grounding
50
POINT
(1) Precautions for wiring to the power supply section
• For 100V AC, 200V AC or 24V DC cable, use the thickest cable
as possible (Max.2mm2) and start twisting them at the position
closest to the connected terminals.
To prevent a short circuit due to loose screws, use the solderless
terminal with insulation sleeve.
• When connection is made between LG and FG terminals, be sure
to connect them to the ground.
Otherwise, the system becomes susceptible to noise.
Since the LG terminal has potential equal to a half of the input
voltage, touching the terminal may lead to an electric shock.
• When grounding the GT155 , ground it with the ground terminal
equipped at the lower-left corner on the GOT main unit back
face.(Refer to the previous page.)
Connect only the ground cables of the bus connection cable and
the CF card extension unit connection cable to the FG terminal.
6.4 Grouding
6.4.1 Grounding the GOT
About grounding
Perform the following three items for grounding.
• Independent grounding should be performed as possible for
the GOT.
Perform grounding works. (grounding resistance 100 or
less)
• When independent grounding cannot be performed for the
GOT, perform "(2) Shared grounding" shown below.
51
Other Other Other
GOT device GOT device GOT device
Grounding Grounding
Grounding examples
(1) Independent grounding (Best)
Power equipment
(servo, etc.)
PLC
Connection cable
CN1A CN1B
FG
LG
CN 2C N3
FG
FG GOT
LG
Panel Ground
grounding terminal block Grounding for
control system
Grounding for power system
52
(2) Shared grounding (Good)
Power equipment
(servo, etc.)
PLC
Connection cable
CN1A CN1B
FG
LG
CN2C N3
FG
FG GOT
LG
Panel
Panel grounding
grounding
Power equipment
(servo, etc.)
Connection cable
CN1A CN1B
FG
CN2 CN3 LG
FG FG GOT
The power equipment and
LG
control equipment are
connected with a wire.
Panel
grounding
Panel grounding
53
Recommended terminal shape
Terminal Solderless
Terminal Solderless
3.2 screw terminal
screw terminal
6.2mm
or less
3.2
6.2mm
or less
Applicable solderless terminal RAV1.25- 3, V2- S3.3, V2- N3A, FV2- N3A
54
6.4.2 Wiring-related malfunction causes and the measures
examples
The malfunction causes in grounding the GOT include potential
difference caused by groundings and noise.
Potential difference and noise may be reduced by taking the following
measures.
When the ground cable and power line of the GOT are installed
together, the GOT may malfunction due to noise.
Separating the ground cable and power line of the GOT in wiring
reduces the influence of noise.
GOT
LG FG
GOT
LG FG
55
Leading of the ground cable from the panel having a control
equipment in the panel having the GOT
When a single ground cable is led from the panel having a control
equipment such as PLC in the panel having the GOT, the cable
may need to be directly connected to the terminal block of the
GOT.
.
Connection
cable
56
The malfunction occurred by the potential difference caused by
the groundings in such a case, may be prevented by reducing the
voltage with the following measure example 1, where the voltage
is reduced.
Connection
cable
GOT
FG
LG
Ground
cable
Use a thick
Ground to
wire as
the panel.
possible.
Connection
cable
GOT
Ground FG
LG
cable
Ground to
the panel.
57
If the GOT is affected by noise when measure example 1 is
taken, the influence of noise may be reduced with the following
measure example 2.
Connection
cable
GOT
FG
LG
Ground
cable Ferrite core
Connection
cable
GOT
Ground FG
cable LG
Ferrite core
Ground to
the panel.
58
6.5 Panel Inside Wiring, Panel Outside Wiring
6.5.1 Panel inside wiring
In wiring, the power line connected to the power or servo amplifier and
the communication cable such as bus connection cable or network
cable must not be mixed.
Mixing the power line and communication cable may cause
malfunction due to noise.
When using an equipment that may occur surge noise, such as molded
case circuit breaker (MCCB), electromagnetic contactor (MC), relay
(RA), solenoid valve, or induction motor, using a surge suppressor is
effective.
For surge suppressor, refer to the following.
6.6 Attaching Surge Suppressor for Control Equipment
Separated power lines and communication cables Mixed power lines and communication cables
Power cable Control panel inside Power cable Control panel inside
GOT GOT
connection connection
cable cable
NFB NFB
MC MC RA RA MC MC RA RA
Drive Drive
control control
wire wire
59
6.5.2 Panel outside wiring
When leading the power line and communication cable outside the
panel, open cable holes at two separate places to lead the cables
separately out.
If cables are led out through the same cable hole for wiring reasons,
the cables are more easily influenced by noise.
Power line
Power line
Communication
cable
Communication
cable
Cable hole
Wiring for leading the power line and communication cable out from the panel
Install the power line and communication cable as apart from each
other as possible in the duct.
If the cables are installed closely with each other for wiring reasons,
using a separator (made of metal) can make the cables less influenced
by noise.
100mm or more
Signal
Power Communication
line
line cable
60
6.6 Attaching Surge Suppressor for Control Equipment
If an improper operation such as communication error occurs in the
GOT in synchronization with ON/OFF of a particular control equipment
(hereinafter abbreviated to load) such as MCCB, electromagnetic
contactor, relay, solenoid valve, or induction motor, the GOT may be
influenced by surge noise.
In such a case, install the ground cable or communication cable apart
from the load.
If the ground cable or communication cable has to be installed close to
the load unavoidably, attaching a surge suppressor is effective.
Attach the surge suppressor at the position closest to the load.
Output equipment
such as PLC's
output module
C
Output L Load
R
Output equipment
such as PLC's
output module
Output D L Load
DC
The surge suppressor must
be attached close to the load.
61
6.7 Wiring FG Cable of Bus Connection Cable
This section describes wiring of the FG cable when a PLC CPU is
connected to the GOT.
POINT
Cable connected to the PLC CPU
Do not install the connection cable together with the main circuit
lines (high voltage, large current) or I/O signal lines.
POINT
(1) GOT terminal block
The terminal block layout of a GOT differs depending on the
model.
Before wiring, confirm the terminal layout of the GOT to be
used.
(2) Ground cables
Up to two ground cables can be connected to the LG and FG
terminals of the GOT respectively.
For three or more ground cables, connect the third or later
ground cables to the LG terminal.
62
(1) When using GT15-C EXSS-1
Not connected
PLC GOT
3)
OUT IN
FG
LG L N LG FG
N (GT15-EXCNB)
L
2SQ cables to
FG terminals,
6) 5) 28cm or less 4) 1)
2)
1)Connect the LG and FG terminals of the terminal block on the GOT
unit power and ground them with a cable.
2)Use the GT15-C BS's FG cable of 28cm or less.
3)Do not connect the GT15-EXCNB's FG ground cable.
4)Connect the GT15-C BS's FG cable on the GOT side to FG of
the GOT unit power's terminal block.
5)Connect the GT15-C BS's FG cable on the PLC side to FG of
the PLC's power supply module.
6)Connect the LG and FG terminals of the terminal block on the PLC
and ground them with a cable.
63
7.Maintenance and Inspection
Inspection
No. Inspection Item Criterion Action
Method
Retighten screws
Check for loose Securely within the
1 GOT mounting status
mounting screws. mounted specified torque
range.
Loose terminal Retighten screws Retighten
Not loose
screws with screwdriver terminal screws
Proximate
Connection solderless Visual check Proper intervals Correct
2
status terminals
Retighten
Loose
Visual check Not loose connector fixing
connectors
screws
Dirt on protection Replace with new
Visual check Not outstanding
Usage sheet one
3
status Foreign material No foreign matter
Visual check Remove, clean
attachment sticking
For applicable protective sheet model or replacement procedure, refer
to GT15 User’s Manual.
64
7.2 Periodic Inspection
Yearly or half-yearly inspection items
The following inspection should also be performed when equipment
has been moved or modified or the wiring changed.
Inspection
No. Inspection Item Criterion Action
Method
Display
0 to 40°C
Ambient Make section For use in
Surround temperature measurement Other control panel,
ing with thermometer portions 0 to 55°C temperature
1
environm or hygrometer inside control
ent Ambient Measure panel is ambient
10 to 90%RH
humidity corrosive gas temperature
Atmosphere No corrosive gas
GOT
Measure voltage
powered Power supply
across terminals Change supply
from 100- voltage 85AC to 242V
of 100-240VAC power
240VAC check
power.
power
2
GOT
powered Input polarity Measure voltage
Left : -
from of 24VDC across terminals Change wiring
Right: +
24VDC power of 24VDC power.
power
Should be mounted Retighten
Looseness Move module
Mounting firmly screws
3
status Dirt, foreign No dirt, foreign matter
Visual check Remove, clean
matter sticking
Loose
Retighten screws Retighten
terminal Not loose
with screwdriver terminal screws
screws
Proximate
Connecti
4 solderless Visual check Proper intervals Correct
on status
terminals
Retighten
Loose
Visual check Not loose connector fixing
connectors
screws
Replace with
Check "GOT new battery
internal battery when the current
voltage status" in battery has
"Time setting & reached the
5 Battery No alarm appears
display" of the specified life
Utility. (Refer to span, even if
the GT15 User's battery voltage
Manual.) low is not
displayed.
65
7.3 Battery Voltage Low Detection and Battery Replacement
The battery is used for backing up the present time or the maintenance
time notification data.
It is recommended that you replace battery periodically.
7.3.1 Applicable battery
The following battery is applicable for GT15 .
Model Descriptionm
GT15-BAT Battery for backup of clock data and maintenance time notification data.
Item Specifications
Type Magnesium manganese dioxide lithium primary battery
Initial voltage 3.0V
Nominal current 1800mAh
Storage life Approx.5 years (Operating ambient temperature of 25°C)
Total power
Refer to Section .
stoppage time
Lithium content 0.49g
Application For backup of clock data and maintenance time notification data.
(1) Keep the GOT power supply on for 10 minutes or more, and turn it
off.
(Executes step 2 to 6 within 5 minutes of powering the GOT power
supply off.)
(3) Remove the old battery from the folder and disconnect the
connector.
66
(4) Connect the new battery to the connector.
(5) Insert the battery into the folder and set it into the GOT backside.
POINT
1. Precautions after battery replacement
Make sure to turn on the GOT power supply once upon comple-
tion of battery replacement.
Failure to do so may decrease the battery life.
67
Appendix Confirming of Versions and Conformed
Standards
(1) Ratings plate
The GOT hardware version, function version, and the standards
conformed by a GOT can be confirmed at the rating plate on the
GOT rear face.
AA
Hardware version
B B
Function version
Conformed standard
68
MEMO
Warranty
Mitsubishi will not be held liable for damage caused by factors found not to be the cause of
Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage,
secondary damage, accident compensation caused by special factors unpredictable by
Mitsubishi; damages to products other than Mitsubishi products; and to other duties.
For safe use
• This product has been manufactured as a general-purpose part for general industries, and
has not been designed or manufactured to be incorporated in a device or system used in
purposes related to human life.
• Before using the product for special purposes such as nuclear power, electric power,
aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.
• This product has been manufactured under strict quality control. However, when installing the
product where major accidents or losses could occur if the product fails, install appropriate
backup or failsafe functions in the system.
HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.