0% found this document useful (0 votes)
3 views

DR-6 Installation Manual (en) - Copy (3)

The document outlines safety instructions and pictograms related to medium voltage switchgear, emphasizing the importance of following proper procedures to avoid damage and hazards. It provides guidance on necessary precautions, documentation, and the responsibility of the owner/operator for safety compliance. Additionally, it highlights the need for trained operators and the maintenance of clear safety symbols throughout the equipment's lifespan.

Uploaded by

hoomanir1980
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
3 views

DR-6 Installation Manual (en) - Copy (3)

The document outlines safety instructions and pictograms related to medium voltage switchgear, emphasizing the importance of following proper procedures to avoid damage and hazards. It provides guidance on necessary precautions, documentation, and the responsibility of the owner/operator for safety compliance. Additionally, it highlights the need for trained operators and the maintenance of clear safety symbols throughout the equipment's lifespan.

Uploaded by

hoomanir1980
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Pictograms in the documentation

The following pictograms apply to the medium voltage switchgear user documents:

CAUTION!
A procedure that can, if not carried out with the proper care, result in damage to
the medium voltage switchgear, the surrounding area or the environment.

WARNING
High Voltage Danger

CAUTION!
Clamping danger

Notes, suggestions and advice.

Make this cubicle, the next one and the previous cubicle, voltage-free, before
carrying out the work described.

Open the load break switch and the earthing switch before carrying out the work
described in the manual.

Consult the indicated information sources first.

Protect the medium voltage switchgear from water and damp.

Related documentation
The following technical documentation for medium voltage switchgear is available:
• Transport manual DR-6C
• User manual DR-6C

vi Installation Manual – DR-6C/ DR-6+ C DW646112


Service and technical support
For information concerning specific settings, maintenance or repair work which are not
covered in the manual, please contact SGC - SwitchGear Company nv.

• When contacting SGC – Switchgear Company nv, always provide the following
information:
− Cubicle designation and characteristics
− Serial number of the cubicle(s)

General safety directions and instructions


SGC – SwitchGear Company nv does not accept any liability for damage or injury caused
by not (strictly) following the safety directions and instructions, or by negligence during the
installation, use, maintenance, or the repair of the medium voltage switchgear and its
accompanying options.
Depending on specific user circumstances, or installed options, extra safety instructions
may be required. Please contact SGC – SwitchGear Company nv immediately if you
encounter a potential danger during the operation of the medium voltage switchgear.

The owner/operator of the medium voltage switchgear is fully responsible at all


times for following the locally applicable safety directions and guidelines.

User manual
• Anyone who uses or operates the medium voltage switchgear, must be familiar with
the contents of the user manual, and follow the directions contained within very
closely. The owner/operator must educate the users in accordance with the user
manual and obey all directions and instructions.
• Never change the order of the required actions.
• Always keep the user manual in the vicinity of the medium voltage switchgear.

Pictograms and safety symbols


The pictograms, symbols and instructions applied to the medium voltage switchgear are a
part of the safety equipment. They may therefore not be covered or removed, and must be
present and clearly readable throughout the entire lifespan of the medium voltage
switchgear.
• Replace or repair unreadable or damaged pictograms, symbols and instruction
immediately. Therefore, contact SGC – SwitchGear Company nv.

Operators
The execution of the work described (transport, installation, use and maintenance) is
strictly reserved for trained and qualified operators, who are familiar with the dangers that
can occur when operating medium voltage switchgear. Temporary staff and personnel in
training may not operate the medium voltage switchgear under any circumstances.