The document outlines fire protection requirements and specifications for a building project in Toledo City, Philippines, emphasizing compliance with NFPA codes. It includes guidelines for sprinkler installation, pipe sizes, and necessary equipment such as fire extinguishers and pumps. The contractor is responsible for securing permits and ensuring all work meets the standards set by the architect and engineer.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views1 page

MEPF 1

The document outlines fire protection requirements and specifications for a building project in Toledo City, Philippines, emphasizing compliance with NFPA codes. It includes guidelines for sprinkler installation, pipe sizes, and necessary equipment such as fire extinguishers and pumps. The contractor is responsible for securing permits and ensuring all work meets the standards set by the architect and engineer.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

REPUBLIC OF THE PHILIPPINES

OFFICE OF THE BUILDING OFFICIAL


CITY OF TOLEDO

RECOMMENDING ISSUANCE:

GENERAL NOTES : FIRE PROTECTION : ABBREVATIONS: SYMBOLS: SECTION HEAD DATE

APPROVED:

ITC - INSPECTOR TEST CONNECTION BUILDING OFFICIAL DATE

1. ALL FIRE PROTECTION WORKS SHALL CONFORM WITH THE LATES 1. USE NON-COMBUSTIBLE CEILING MATERIAL. - PENDENT SPRINKLER HEAD
EDITION OF NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES RN - RISER NIPPLE
2. MAXIMUM RADIUS ALLOWED PER SPRINKLER 1S 2.0 M. - UPRIGHT SPRINKLER HEAD
NO. 13, 14, 20 & 72.
FHV - FIRE HOSE VALVE
3. FOR ADDITIONAL HEADS MAX. OF 5 HEADS ARE ALLOWED FOR - SIDEWALL SPRINKLER HEAD (EXTENDED)
2. READ THE DRAWING CONNECTION WITH OTHER RELATED DRAWINGS AFSR - AUTOMATIC FIRE SPRINKLER RISER
EVERY TAPPING TO THE EXISTING LOCATION OF SPRINKLER HEADS.
AND SPECIFICATIONS. THE ARCHITECT AND THE ENGINEER SHALL BE - SIDEWALL SPRINKLER HEAD (ORDINARY)
NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES FOUND THEREIN. 4. PROVIDE SPRINKLER HEAD GUARD AT STORAGE AREAS. DSPR - DRY STAND PIPE RISER FHC
- FIRE HOSE CABINET
3. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF 5. USED 215°F HEAD RATING FOR KITCHEN AREAS AND 165°F PG - PRESSURE GAUGE
SPRINKLER IN COORDINATION WITH THE ARCHITECTURAL CEILING HEAD FOR OTHER AREAS. - HANGER
PRV - PRESSURE RELIEF VALVE
LAYOUT. ANY RELOCATION SHALL BE SUBJECT TO ARCHITECTS AND
6. DO NOT REDUCE EXISTING NUMBER OF HEAD PROVISON AT SITE WFS - WATER FLOW SWITCH - 2-WAY BRACKET
ENGINEER'S APPROVAL.
PROVIDE 9mmØ ROUND BAR HANGER ACHORGE DIRECTLY TO EXISTING SLAB.
FCV - FLOOR CONTROL VALVE - 4-WAY BRACKET
4. ALL DRAIN PIPES FOR INSPECTORS TEST CONNECTION AND DRAIN
7. ALL SPRINKLER PIPES SHALL BE PAINTED WITH INTERNATIONAL RED
VALVES SHALL BE PIPED TO THE NEAREST FLOOR DRAIN / SLOPE SINK
COORDINATE WITH ADMINISTRATION OFFICE FOR SPRINKLER INSTALLATION. CV - CHECK VALVE - GATE VALVE
PROVIDED BY THE PLUMBING CONTRACTOR.
GV - GATE VALVE - GATE HOSE VALVE
5. PIPE SLEEVES SHALL BE PROVIDED FOR ALL PIPES PASSING THRU SLABS. 8. PROVIDE AT LEAST ONE (1) UNIT 10 LBS. HCFC PORTABLE

WALLS, GIRDER AND BEAMS. FIRE EXTINGUISHERS FOR EVERY ROOM. SS - SUPERVISORY SWITCH - CHECK VALVE

6. MINIMUM PIPE SIZES FOR ALL SPRINKLER SHALL BE 25mm 9. UPRIGHT SPRINKLER HEADS TO BE USED AT OPEN CEILING AREAS ONLY. FP - FIRE PUMP
- ALARM CHECK VALVE
OTHERWISE NOTED.
JP - JOCKEY PUMP
- FLOW DETECTOR
7. ALL PIPE SIZES ARE IN MILLIMETER (mm) DIAMETER, UNLESS OTHERWISE
MM - MILLIMETER
NOTED. - FLUSHING CONNECTION
TYP - TYPICAL
8. WORKMANSHIP : THE WORK THROUGHOUT SHALL BE EXECUTED IN THE - CONCENTRIC CONNECTION
BEST AND MOST THOROUGH MANNER KNOWN TO TRADE AND TO THE GPM - GALLONS PER MINUTE
- ECCENTRIC REDUCER
SATISFACTION OF THE ARCHITECT AND THE ENGINEER.
PSI - POUNDS PER SQUARE INCH.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL - 2-WAY FIRE DEPARTMENT CONNECTION

GOVERNMENT / LOCAL CONSTRUCTION AND OPERATION PERMIT AND PAY


HZ - HERTZ
- 2-WAY ROOF MANIFOLD CONNECTION
ALL REQUIRED FEES. V - VOLT
- PORTABLE FIRE EXTINGUISHER
10. REFER TO TECHNICAL SPECIFICATIONS FOR PUMP & MATERIAL FP - FIRE PROTECTION 5KG CAP (DRY CHEM)
SPECIFICATIONS.
- FIRE EXTINGUISHER (WHEELED
11. PIPE HANGERS & SWAY BRACES LOCATION SHALL BE AS PER NFPA SCHEDULE OF EQUIPMENTS TYPE )-25KG CAP (DRY CHEM)
STANDARD AND LEAST ONE (1) HANGER BETWEEN HEAD. CAPACITY HEAD POWER
ELECTRICAL
EQUIPTMENT REMARKS
(gpm) (psi) (hp)
VICINITY MAP VOLTS PHASE HERTZ
HORIZONTAL SPLIT CASE PUMP WITH RATED
CAPACITY OF 500GPM @ 150 PSI
FIRE PUMP 500 150 75 400 3 60 THE PUMP CUT - IN POINT SHOULD
NOT TO SCALE BE 145 PSI, 5 PSI LESS THAN JOCKEY PUMP
; CUT-OUT 160 PSI
VERTICAL IN-LINE PUMP
CAPACITY OF 20 GPM AT 85PSI
JOCKEY PUMP 50 160 7.5 400 3 60 THE PUMP CUT-IN 150 PSI AND
PUMP CUT-OUT IS 160 PSI

DESIGNED BY: THIS DRAWING IS ISSUED FOR :


DEVELOPED BY: APPROVED BY: S E A L PROJECT TITLE APPROVED BY: SHEET CONTENT: SHEET NO.
R.A.9266 SECTION 33 4PH : PAMBANSANG PABAHAY PARA SA PILIPINO AS BUILT ESTIMATE

Drawing and specifications and other contract documents 1 DRAFTED BY:


BIDDING FABRICATION

ENGR. EDWIN TEVES


PROFESSIONAL MECHANICAL ENGINEER
signed, stamped or sealed, as instruments of service, are
the intellectual property and documents of the architect,
whether the object for which they are made is executed or
not, if shall be unlawful for any person to duplicate or to
" MYCOLLEX-WESTTOWN":
A PROPOSED 10-STOREY SOCIALIZED
ALEX T. TAN
(EASTLAND PROPERTY VENTURES, INC.)
2

3
CAMILLE BAJO
DATE DRAFTED:
04-10 - 2024
BUILDING PERMIT

CONSTRUCTION
OWNER'S APPROVAL

DEVELOPMENT PERMIT
1 5
PRC NO: 3430 DATE: 12-08-1998 make copies of said documents for use in the repetition of
and for other projects of building, whether executed partly REVISIONS DATE REVISIONS DATE
CONDOMINIUM DEVELOPMENT" BLDG 1 TYPE 1 OWNER
4

MEFP
PTR NO: DATE: in whole, without the written consent of architect or
0672249 01-02-2024
EASTLAND PROPERTY VENTURES, INC. a u t h o r o f s a i d d o c u m e n t s . 5