RECOMMENDING ISSUANCE:
APPROVED:
1. ALL FIRE PROTECTION WORKS SHALL CONFORM WITH THE LATES 1. USE NON-COMBUSTIBLE CEILING MATERIAL. - PENDENT SPRINKLER HEAD
EDITION OF NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES RN - RISER NIPPLE
2. MAXIMUM RADIUS ALLOWED PER SPRINKLER 1S 2.0 M. - UPRIGHT SPRINKLER HEAD
NO. 13, 14, 20 & 72.
FHV - FIRE HOSE VALVE
3. FOR ADDITIONAL HEADS MAX. OF 5 HEADS ARE ALLOWED FOR - SIDEWALL SPRINKLER HEAD (EXTENDED)
2. READ THE DRAWING CONNECTION WITH OTHER RELATED DRAWINGS AFSR - AUTOMATIC FIRE SPRINKLER RISER
EVERY TAPPING TO THE EXISTING LOCATION OF SPRINKLER HEADS.
AND SPECIFICATIONS. THE ARCHITECT AND THE ENGINEER SHALL BE - SIDEWALL SPRINKLER HEAD (ORDINARY)
NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES FOUND THEREIN. 4. PROVIDE SPRINKLER HEAD GUARD AT STORAGE AREAS. DSPR - DRY STAND PIPE RISER FHC
- FIRE HOSE CABINET
3. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF 5. USED 215°F HEAD RATING FOR KITCHEN AREAS AND 165°F PG - PRESSURE GAUGE
SPRINKLER IN COORDINATION WITH THE ARCHITECTURAL CEILING HEAD FOR OTHER AREAS. - HANGER
PRV - PRESSURE RELIEF VALVE
LAYOUT. ANY RELOCATION SHALL BE SUBJECT TO ARCHITECTS AND
6. DO NOT REDUCE EXISTING NUMBER OF HEAD PROVISON AT SITE WFS - WATER FLOW SWITCH - 2-WAY BRACKET
ENGINEER'S APPROVAL.
PROVIDE 9mmØ ROUND BAR HANGER ACHORGE DIRECTLY TO EXISTING SLAB.
FCV - FLOOR CONTROL VALVE - 4-WAY BRACKET
4. ALL DRAIN PIPES FOR INSPECTORS TEST CONNECTION AND DRAIN
7. ALL SPRINKLER PIPES SHALL BE PAINTED WITH INTERNATIONAL RED
VALVES SHALL BE PIPED TO THE NEAREST FLOOR DRAIN / SLOPE SINK
COORDINATE WITH ADMINISTRATION OFFICE FOR SPRINKLER INSTALLATION. CV - CHECK VALVE - GATE VALVE
PROVIDED BY THE PLUMBING CONTRACTOR.
GV - GATE VALVE - GATE HOSE VALVE
5. PIPE SLEEVES SHALL BE PROVIDED FOR ALL PIPES PASSING THRU SLABS. 8. PROVIDE AT LEAST ONE (1) UNIT 10 LBS. HCFC PORTABLE
WALLS, GIRDER AND BEAMS. FIRE EXTINGUISHERS FOR EVERY ROOM. SS - SUPERVISORY SWITCH - CHECK VALVE
6. MINIMUM PIPE SIZES FOR ALL SPRINKLER SHALL BE 25mm 9. UPRIGHT SPRINKLER HEADS TO BE USED AT OPEN CEILING AREAS ONLY. FP - FIRE PUMP
- ALARM CHECK VALVE
OTHERWISE NOTED.
JP - JOCKEY PUMP
- FLOW DETECTOR
7. ALL PIPE SIZES ARE IN MILLIMETER (mm) DIAMETER, UNLESS OTHERWISE
MM - MILLIMETER
NOTED. - FLUSHING CONNECTION
TYP - TYPICAL
8. WORKMANSHIP : THE WORK THROUGHOUT SHALL BE EXECUTED IN THE - CONCENTRIC CONNECTION
BEST AND MOST THOROUGH MANNER KNOWN TO TRADE AND TO THE GPM - GALLONS PER MINUTE
- ECCENTRIC REDUCER
SATISFACTION OF THE ARCHITECT AND THE ENGINEER.
PSI - POUNDS PER SQUARE INCH.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SECURING ALL - 2-WAY FIRE DEPARTMENT CONNECTION
3
CAMILLE BAJO
DATE DRAFTED:
04-10 - 2024
BUILDING PERMIT
CONSTRUCTION
OWNER'S APPROVAL
DEVELOPMENT PERMIT
1 5
PRC NO: 3430 DATE: 12-08-1998 make copies of said documents for use in the repetition of
and for other projects of building, whether executed partly REVISIONS DATE REVISIONS DATE
CONDOMINIUM DEVELOPMENT" BLDG 1 TYPE 1 OWNER
4
MEFP
PTR NO: DATE: in whole, without the written consent of architect or
0672249 01-02-2024
EASTLAND PROPERTY VENTURES, INC. a u t h o r o f s a i d d o c u m e n t s . 5
TIN: ADDRESS: 2F TSC RESIDENTIAL SUITES, PRES. MAGSAYSAY ST.,
ADDRESS: 2F TSC RESIDENTIAL SUITES, PRES. MAGSAYSAY ST., CEBU CITY 119-265-987 PLACE: LAPU-LAPU CITY LOCATION: BRGY. CANLUMAMPAO, TOLEDO CITY, PROVINCE OF CEBU 6
CEBU CITY, 6000