The Chemtrac Turbidity Sensor uses an infrared LED for accurate turbidity measurement ranging from 0.01 to 1,000 NTU with a single point calibration process. It features a maintenance-free design with no moving parts and includes an auto-cleaning function to ensure consistent performance. The HydroACT family of analyzers allows for customizable configurations and additional measurement options, making it a versatile solution for water treatment professionals.

Uploaded by

derson
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
10 views

Turbidity-Sensor-Data-Sheet

The Chemtrac Turbidity Sensor uses an infrared LED for accurate turbidity measurement ranging from 0.01 to 1,000 NTU with a single point calibration process. It features a maintenance-free design with no moving parts and includes an auto-cleaning function to ensure consistent performance. The HydroACT family of analyzers allows for customizable configurations and additional measurement options, making it a versatile solution for water treatment professionals.

Uploaded by

derson
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

TURBIDITY SENSOR

NTU with HydroACT Series

Turbidity
DESCRIPTION
The Chemtrac Turbidity Sensor incorporates an infrared LED for a nephelometric (90
degree) light scatter measurement of turbidity (NTU/FTU). The sensor, which only
requires a one point calibration, can be setup to measure either 0.01 to 100 NTU, or 0.1
to 1,000 NTU. A flush option is also available to help keep the optics clean in higher
turbidity applications. Chemtrac's Turbidity Sensor is built to last with a stainless probe
body and sapphire optics. And there are no moving parts, wiper arms, or seals that ever
need replacing.

FEATURES
Autoclean solid state optical sensor - no moving parts
·
Single point calibration - no ‘zero’ required
·
Stable and reliable - excellent process control
·
’Maintenance free’ with up to 1 year between
·
calibration
From 0.01-1000 NTU (0.01-2000 mg/l, application dependent)
·
·Up to 145 psi
·Extremely low total cost of ownership

SIMPLE CALIBRATION
Whether calibrating to a standard or grab sample, calibration is made simple with
easy to follow menu prompts and only needing to calibrate one point.

RELIABLE AUTO CLEANING


Auto cleaning the sensor is accomplished with water flow jet-flushing, ensuring
accuracy is maintained without the need for mechanical wiper arm maintenance.

HYDROACT ANALYZER - RELIABLE, SCALABLE SOLUTIONS


The HydroACT family of analyzers/controllers offers state of the art features allowing
users to specify virtually any configuration of measurements and system features they
require. It is simple to mix and match one or more NTU sensor with additional
measurements like Streaming Current, Particle Counter, Dissolved Oxygen, pH, Chemtrac, Inc.
Chlorine, Chlorine Dioxide, Ozone, UV254 Organics, Conductivity and others. There 1555 Oakbrook Drive
are also a wide selection of analyzer features to choose from such as process control Suite 100
Norcross, GA 30093
options, analog & digital I/O, digital communications, remote access (web server with USA
email alerts), data logging, and others. By paying for only what is needed, HydroACT
PH: 770.449.6233
analyzers offer water treatment professionals a more affordable solution. US: 800.442.8722
FX: 770.447.0889
www.chemtrac.com
GENERAL SPECIFICATIONS
ANALYZER
HA2 HA4 HA8
Power 100-240 VAC / 0.25 A or 12 VDC / 0.8 A (standard) or 24 VDC (optional)
Display 4.3”, 480x272, 8 bit, grayscale 4.3”, 480x272, 24 bit, color
Sensor Inputs Up to 2 Up to 4 Up to 8
Sensor Options TSS/NTU, Free Cl, Total Cl, Cl Dioxide, Chlorite, Ozone, pH with Temperature
Ozone, ORP, SCM, UV254 organics, DO, Conductivity, Particle Counter

External Input (optional) 4-20 mA, 4-20 mA loop-powered, +/- 2000 mV for pH / ORP / ISEs
Analog Outputs (optional) Up to 2 Up to 4 Up to 8
Menu configurable outputs: 4-20 mA (Note: unused sensor inputs can be used as outputs)
Relays (optional) Up to 4 Up to 8 Up to 16
SPST, electromechanical, 380 VAC, 6 A max
Digital Inputs (optional) Up to 4 Up to 8 Up to 16
Alarms & Thresholds 2 user-configurable alarms & thresholds with deadband and delay for each parameter and control output HA2 / HA4
Control Loops (optional) Up to 2 Up to 4 Up to 8
Control Types (optional) High / Low Threshold PID (with start delay and SP ramping options), feed forward (NTU/UV),
flow pacing, high/low threshold, timer

Communication (optional) Modbus ASCII/RTU (RS485), Modbus TCP (Ethernet), PROFIBUS DP


Data & Event Logging 1,000 event / status records 1 million records stored internally
stored in internal memory storage expandable with MicroSD card

Modem (optional) None GSM / GPRS / 3G intergrated modem


Remote Access (optional) None Internet browser access, alerts and reports via email (requires ethernet or modem card)
Enclosure ABS flame retardant, NEMA 4X / IP65
Dimensions & Weight HA2 & HA4: 9 in (230 mm) x 12.2 in (309 mm) x 4.1 in (103 mm); 4.4 lbs (2 kg) HA8
HA8: 18 in (460 mm) x 12.2 in (309 mm) x 4.1 in (103 mm); 4.4 lbs (2 kg)

TURBIDITY & SUSPENDED SOLIDS SENSOR*

Range: Selectable within 0.01-1000 NTU,


0.01-2000 mg/L (application dependent)
Typical Ranges: 0.01-20 NTU, 0.01-100 NTU, 0.01-1000 NTU Turbidity Sensor
Linearity: r 2 > 0.99
Response Times: T 90 > 10s (adjustable based on averaging)
Accuracy: < 1% of measured value or 0.01 NTU (whichever is greater)
Repeatability: < 0.3% of measured value or
0.005 NTU (whichever is the greater) (Ref: ISO 15839)
Unit of Detection: 0.01 NTU (0-10 NTU, Ref: ISO 15839)
Temperature: -20 to 85+°C
Pressure: 0-145 psi
Averaging: 10s - 10min
Lamp Source: IR LED, 860nm
Cleaning Cycles: User settable cleaning cycle time and cleaning time
Cleaning: Autoclean water jet
Enclosure Rating: IP65
Sensor Environmental Protection: IP68
Display: Value and alarms and graphs at the same time, controller dependent
Resolution: 0.001 NTU (0-2), 0.01 NTU (2-10), 0.1 NTU (10-100), 1 NTU (>100)
Calibration: One point (zero not required) Flow Chamber Cal Chamber
Diameter: 1.5” (38mm)
Length: 11” (278mm)

*Sensor not EPA approved

04/18