PART II
CLASSIFICATION PROCEDURES,
TEST METHODS AND CRITERIA
RELATING TO
SELF-REACTIVE SUBSTANCES OF
DIVISION 4.1
AND ORGANIC PEROXIDES OF
DIVISION 5.2
- 195 -
Copyright © United Nations. All rights reserved
Copyright © United Nations. All rights reserved
CONTENTS OF PART II
NOTE 1: The country or organisation of origin of each test method is indicated in brackets after each test
name.
NOTE 2: The test method recommended for use with each test type is indicated in bold italics and by an
asterisk (see sub-section 1.6 of the General Introduction).
Section Page
- 197 -
Copyright © United Nations. All rights reserved
Section Page
- 198 -
Copyright © United Nations. All rights reserved
Section Page
- 199 -
Copyright © United Nations. All rights reserved
Copyright © United Nations. All rights reserved
SECTION 20
INTRODUCTION TO PART II
20.1 Purpose
20.1.1 Part II of the test manual presents the United Nations schemes for the classification of self-
reactive substances of Division 4.1 and organic peroxides of Division 5.2 (see respectively sub-
section 2.4.2.3 and section 2.5.3 of the Model Regulations). It includes a description of the procedures, test
methods and criteria considered to be the most suitable for providing competent authorities with the
necessary information to arrive at a proper classification of these substances for transport. It should be used
in conjunction with the classification principles given in paragraphs 20.4.2 (Division 4.1) and 20.4.3
(Division 5.2) and the flow chart given in Figure 20.1 (see also 2.4.2.3.3 and 2.5.3.3 in the Model
Regulations).
20.1.2 Self-reactive substances and organic peroxides are classified into seven types according to
the hazard. The scheme for classifying these substances is illustrated in Figure 20.1. The tests are performed
in two stages. In the first stage, for the safety of laboratory workers, preliminary small scale tests should
be performed to ascertain the stability and sensitivity of the substance. In the second stage, classification
tests should be performed.
20.2 Scope
(b) They are oxidizing substances according to the assignment procedure of Division 5.1;
(c) They are organic peroxides according to the criteria of Division 5.2;
(d) Their heat of decomposition (see 20.3.3.3) is less than 300 J/g; or
20.2.2 New organic peroxides offered for transport should be subjected to the classification
procedures as set out in this section unless the organic peroxide formulation contains:
(a) Not more than 1.0% available oxygen from the organic peroxides when containing not
more than 1.0% hydrogen peroxide; or
(b) Not more than 0.5% available oxygen from the organic peroxides when containing
more than 1.0% but not more than 7.0% hydrogen peroxide.
20.2.3 In this context a new substance is one which, in the opinion of the competent authority,
involves any of the following:
(a) A new self-reactive substance which meets the definition given in paragraph
2.4.2.3.1.1 of the Model Regulations, or a mixture of already classified self-reactive
substances which is considered to be significantly different from those already
classified;
- 201 -
Copyright © United Nations. All rights reserved
(c) A new organic peroxide which meets the definition given in paragraph 2.5.1 of the
Model Regulations, or a mixture of already classified organic peroxides which is
considered to be significantly different from those already classified.
20.2.4 Mixtures of organic peroxide formulations currently assigned to a generic entry may be
classified as the same type of organic peroxide as that of the most dangerous component and be transported
under the conditions of transport given for this type. However, as two components can form a thermally less
stable mixture, the self-accelerating decomposition temperature (SADT) of the mixture should be determined
and, if necessary, the control and emergency temperature derived from the SADT in accordance with
paragraph 2.5.3.4 of the Model Regulations.
20.2.5 The classification procedure should be undertaken before a new product is offered for
transport.
20.2.6 Any substance which shows the properties of a self-reactive substance (except type G)
should be classified as such, even if this substance gives a positive test result according to the test method for
self-heating substances of Division 4.2 (see section 32.5.2 of this Manual and Chapter 2.4 of the Model
Regulations).
It is essential for the safety of laboratory workers that small-scale preliminary tests are
performed before attempting to handle larger quantities. This involves tests for determining the
sensitiveness of the substance to mechanical stimuli (impact and friction), and to heat and flame.
Generally four types of small scale test may be used to make a preliminary safety
assessment:
(c) A test to assess thermal stability and the exothermic decomposition energy; and
20.3.3.1 For safety, it is usual to perform the tests requiring the smallest quantity of material first.
20.3.3.2 Impact and friction sensitiveness may be assessed using one of the tests in series 3 of the
Class 1 acceptance procedure (see Part I).
- 202 -
Copyright © United Nations. All rights reserved
20.3.3.3 Thermal stability and exothermic decomposition energy may be estimated using a suitable
calorimetric technique such as differential scanning calorimetry or adiabatic calorimetry. In using such
techniques, special care should be taken in interpreting the results when:
- Evaporation of constituents will lower the exothermicity (sealed sample vessels should
normally be used);
- The presence of air may critically affect the measured decomposition energy;
- There is a large difference between the specific heats of the reactants and products;
and
- Using rapid heating rates (when differential scanning calorimetry is used, the heating
rates should normally be in the range of 2 to 5 K/min).
If differential scanning calorimetry is used, the extrapolated onset temperature is defined as being the point
of intersection of the tangent drawn at the point of greatest slope on the leading edge of the peak with the
extrapolated baseline.
20.3.3.4 Any suitable method may be used to assess the effect of ignition provided it adequately
identifies those materials which react violently under little or no confinement.
- 203 -
Copyright © United Nations. All rights reserved
Figure 20.1 (a): FLOW CHART SCHEME FOR SELF-REACTIVE SUBSTANCES AND
ORGANIC PEROXIDES
Box 1
Does it
propagate a
Box 2 1.1 Yes detonation ? 1.3 No
10.1 Yes
- 204 -
Copyright © United Nations. All rights reserved
Figure 20.1 (b): FLOW CHART SCHEME FOR SELF-REACTIVE SUBSTANCES AND
ORGANIC PEROXIDES (cont’d)
from box 9
of figure 2.1 (a)
Box 11
Is
the self-reactive
substance or organic peroxide
to be considered for transport
in IBCs or tanks, or 11.1 Yes
for exemption
?
11.2 No
Box 12
What is its
explosive power
12.1 Not low 12.3 None
?
12.2 Low
Box 13
What
is the effect of
heating it under defined
13.1 Low confinement
?
13.2 None
- 205 -
Copyright © United Nations. All rights reserved
20.4.1.1 The principles of classification of self-reactive substances and organic peroxides are given in
sub-sections 20.4.2 and 20.4.3 respectively (see also paragraphs 2.4.2.3.3 and 2.5.3.3 of the Model
Regulations). The general scheme for classification (flow chart) is shown in Figure 20.1. Self-reactive
substances and organic peroxides are classified into seven types according to the hazard. In order to
determine the substance type, it is necessary to determine the properties as requested in the boxes of the flow
chart and the additional requirements in the classification principles. The types range from type A, which is
not accepted for transport in the packaging in which it is tested, to type G which is exempted from the
provisions for self-reactive substances of Division 4.1 or organic peroxides of Division 5.2.
The classification of types B to F is directly related to the maximum quantity allowed in one packaging.
20.4.1.3 The self-accelerating decomposition temperature (SADT) is defined as the lowest ambient
temperature at which self-accelerating decomposition may occur in a substance in the packaging as used in
transport (see sub-section 2.5.3.4 of the Model Regulations). An SADT should be determined in order to
decide if:
(c) When appropriate, a substance meets the SADT criterion for self-reactive substances.
20.4.1.4 When appropriate, the physical form of the substance should be determined as set out under
definition of liquids in paragraph 1.2.1 of the Model Regulations.
20.4.1.5 The substance type, physical form and whether or not temperature control is required are
used to make the assignment of the substance to the appropriate generic entry.
(a) Any substance which can detonate or deflagrate rapidly, as packaged for transport,
should be prohibited from transport under the provisions for self-reactive substances
of Division 4.1 in that packaging (defined as self-reactive substance type A, exit
box A of Figure 20.1);
(b) Any substance possessing explosive properties and which, as packaged for transport,
neither detonates nor deflagrates rapidly, but is liable to undergo a thermal explosion
in that package, should also bear an "EXPLOSIVE" subsidiary risk label. Such a
substance may be packaged in amounts of up to 25 kg unless the maximum quantity
has to be limited to a lower amount to preclude detonation or rapid deflagration in the
package (defined as self-reactive substance type B, exit box B of Figure 20.1);
- 206 -
Copyright © United Nations. All rights reserved
(i) detonates partially, does not deflagrate rapidly and shows no violent effect
when heated under confinement; or
(ii) does not detonate at all, deflagrates slowly and shows no violent effect when
heated under confinement; or
(iii) does not detonate or deflagrate at all and shows a medium effect when heated
under confinement;
may be accepted for transport in packages of not more than 50 kg net mass (defined as
self-reactive substance type D, exit box D of Figure 20.1);
(e) Any substance which, in laboratory testing, neither detonates nor deflagrates at all and
shows low or no effect when heated under confinement may be accepted for transport
in packages of not more than 400 kg/450 litres (defined as self-reactive substance
type E, exit box E of Figure 20.1);
(f) Any substance which, in laboratory testing, neither detonates in the cavitated state nor
deflagrates at all and shows only a low or no effect when heated under confinement as
well as low or no explosive power may be considered for transport in IBCs or tanks
(defined as self-reactive substance type F, exit box F of Figure 20.1); for additional
provisions, see Model Regulations, sub-section 4.1.7.2 and packing instruction
IBC520, sub-section 4.2.1.13 and portable tank instruction T23;
(g) Any substance which, in laboratory testing, neither detonates in the cavitated state nor
deflagrates at all and shows no effect when heated under confinement nor any
explosive power should be exempted from classification as a self-reactive substance of
Division 4.1 provided that the formulation is thermally stable (self-accelerating
decomposition temperature 60 °C to 75 °C for a 50 kg package) and any diluent meets
the requirements of paragraph 2.4.2.3.5 of the Model Regulations (defined as self-
reactive substance type G, exit box G of Figure 20.1). If the formulation is not
thermally stable or a compatible diluent having a boiling point less than 150 °C is used
for desensitization, the formulation should be defined as self-reactive liquid/solid
type F.
(a) Any organic peroxide formulation which can detonate or deflagrate rapidly, as
packaged for transport, should be prohibited from transport in that packaging under
Division 5.2 (defined as organic peroxide type A, exit box A of Figure 20.1);
(b) Any organic peroxide formulation possessing explosive properties and which, as
packaged for transport, neither detonates nor deflagrates rapidly, but is liable to
undergo a thermal explosion in that package, should bear an "EXPLOSIVE"
subsidiary risk label. Such an organic peroxide may be packaged in amounts of up
to 25 kg unless the maximum quantity has to be limited to a lower amount to preclude
detonation or rapid deflagration in the package (defined as organic peroxide type B,
exit box B of Figure 20.1);
- 207 -
Copyright © United Nations. All rights reserved
(c) Any organic peroxide formulation possessing explosive properties may be transported
without an "EXPLOSIVE" subsidiary risk label when the substance as packaged
(maximum 50 kg) for transport cannot detonate or deflagrate rapidly or undergo a
thermal explosion (defined as organic peroxide type C, exit box C of Figure 20.1);
(i) detonates partially, does not deflagrate rapidly and shows no violent effect
when heated under confinement; or
(ii) does not detonate at all, deflagrates slowly and shows no violent effect when
heated under confinement; or
(iii) does not detonate or deflagrate at all and shows a medium effect when heated
under confinement
is acceptable for transport in packages of not more than 50 kg net mass (defined as
organic peroxide type D, exit box D of Figure 20.1);
(e) Any organic peroxide formulation which, in laboratory testing, neither detonates nor
deflagrates at all and shows low or no effect when heated under confinement is
acceptable for transport in packages of not more than 400 kg/450 litres (defined as
organic peroxide type E, exit box E of Figure 20.1);
(f) Any organic peroxide formulation which, in laboratory testing, neither detonates in the
cavitated state nor deflagrates at all and shows only a low or no effect when heated
under confinement as well as low or no explosive power may be considered for
transport in IBCs or tanks (defined as organic peroxide type F, exit box F of
Figure 20.1); for additional provisions, see Model Regulations, sub-section 4.1.7.2 and
packing instruction IBC520, sub-section 4.2.1.13 and portable tank instruction T23;
(g) Any organic peroxide formulation which, in laboratory testing, neither detonates in the
cavitated state nor deflagrates at all and shows no effect when heated under
confinement nor any explosive power should be exempted from Division 5.2,
provided that the formulation is thermally stable (self-accelerating decomposition
temperature is 60 °C or higher for a 50 kg package) and for liquid formulations diluent
type A is used for desensitization (defined as organic peroxide type G, exit box G of
Figure 20.1). If the formulation is not thermally stable or a diluent other than type A is
used for desensitization, the formulation should be defined as organic peroxide type F.
20.4.4.1 Paragraphs 20.4.2 and 20.4.3 refer only to those properties of self-reactive substances and
organic peroxides which are decisive for their classification. These properties should be determined
experimentally.
20.4.4.2 The test methods for determining the type of self-reactive substance or organic peroxide are
grouped into eight series, lettered A to H, designed to provide the information necessary to answer the
questions in the flow chart given in Figure 20.1 and to apply the principles for classification.
20.4.4.3 Test series A comprises laboratory tests and criteria concerning propagation of detonation as
requested in box 1 of the flow chart.
20.4.4.4 Test series B comprises a test and criteria concerning the propagation of detonation of the
substance as packaged for transport, as requested in box 2 of the flow chart.
- 208 -
Copyright © United Nations. All rights reserved
20.4.4.5 Test series C comprises laboratory tests and criteria concerning propagation of deflagration
as requested in boxes 3, 4 and 5 of the flow chart.
20.4.4.6 Test series D comprises a test and criteria concerning the propagation of a rapid deflagration
of the substance as packaged for transport, as requested in box 6 of the flow chart.
20.4.4.7 Test series E comprises laboratory tests and criteria concerning the determination of the
effect of heating under defined confinement, as requested in boxes 7, 8, 9 and 13 of the flow chart.
20.4.4.8 Test series F comprises laboratory tests and criteria concerning the explosive power of
substances which are considered for transport in Intermediate Bulk Containers (IBCs) or tanks, or for
exemption (see box 11 of the flow chart), as requested in box 12 of the flow chart.
20.4.4.9 Test series G comprises tests and criteria concerning the determination of the effect of a
thermal explosion of the substance as packaged for transport, as requested in box 10 of the flow chart.
20.4.4.10 Test series H comprises tests and criteria concerning the determination of the self-
accelerating decomposition temperature of organic peroxides and self-reactive, or potentially self-reactive
substances.
20.4.5.1 The ordering of test series A to H relates more to the sequence of assessing results than to
the order in which tests are conducted. The recommended sequence of laboratory scale testing is test
series E, H, F, C and then A. Some tests may not be required - see the introduction to each test series.
20.4.5.2 The package tests of test series B, D and G need be performed only if indicated by the results
from the corresponding tests in test series A, C and E.
20.5.1 Examples of a test report and a classification are illustrated in figures 20.2 and 20.3
respectively.
20.5.2 To allow for analytical uncertainties, the concentration of the substance to be transported
may be up 2% higher than the concentration tested. If an organic peroxide is tested, the available oxygen
content should be given in the General Data section of the report. Similarly, if a self-reactive substance is
tested, the activator type and concentration, if any, should be given.
20.5.3 If the preliminary test results indicate that the substance is very sensitive to initiation (e.g. by
impact, friction or sparks), the results should be recorded in the report.
- 209 -
Copyright © United Nations. All rights reserved
2. General data
- 210 -
Copyright © United Nations. All rights reserved
9. Proposed assignment
- 211 -
Copyright © United Nations. All rights reserved
TERT-BUTYL PEROXYBENZOATE
Box 1
Does it
propagate a
1.1 Yes detonation ? 1.3 No
Box 2
10.1 Yes
- 212 -
Copyright © United Nations. All rights reserved
SECTION 21
TEST SERIES A
21.1 Introduction
20.1.1 Test series A comprises laboratory tests and criteria concerning propagation of detonation as
requested in box 1 of Figure 20.1.
21.1.2 The question "Does it propagate a detonation?" (box 1 of Figure 20.1) is answered on the
basis of the results of one of the test methods in Table 21.1. If a liquid is being considered for transport in
tank-containers or IBCs with a capacity exceeding 450 litres, a cavitated version of a Series A test may be
used (see Appendix 3).
a
Recommended test
All tests are considered to be equivalent and only one test method has to be used.
21.2.2 For organic peroxides, a combination of a test for explosive power (any test of series F
except test F.5) with two tests for the effects of heating under confinement may be used as a screening
procedure for assessing the ability to propagate a detonation. A test of series A need not be performed if:
(a) A "No" result is obtained from the explosive power test; and
(b) A "No" or "Low" result is obtained from test E.2 and either test E.1 or E.3.
For transport in packages (excluding IBCs), if the screening procedure indicates that a Series A test is not
needed, the question in box 1 is answered with a "No". However, if the substance is being considered for
transport in tank containers or IBCs, or for exemption, then a series A test is required unless the result of a
series A test on a formulation of the substance with a higher concentration and the same physical state
is "No".
- 213 -
Copyright © United Nations. All rights reserved
21.3.1 As the apparent density of the substance has an important effect on the results from series A
tests, it should always be recorded. The apparent density of solids should be determined from measurement
of the tube volume and sample mass.
21.3.2 If a mixture can separate out during transport, the test should be performed with the initiator
in contact with the potentially most explosive part.
21.3.3 The tests should be performed at ambient temperature unless the substance is to be
transported under conditions where it may change its physical state or density. Organic peroxides and self-
reactive substances which require temperature control should be tested at the control temperature if below
ambient temperature.
21.3.4 The preliminary procedure should be performed before performing these tests (see
section 20.3).
21.3.5 When a fresh batch of steel tubes is used, calibration tests using water (for tests on liquids)
and an inert, organic solid (for tests on solids) should be performed to determine the average blank
fragmentation length. The "No" / "Partial" criteria should be set to 1.5 times the average blank fragmentation
length.
- 214 -
Copyright © United Nations. All rights reserved
21.4.1.1 Introduction
This test is used to measure the ability of a substance to propagate a detonation by subjecting
it to a detonating booster charge under confinement in a steel tube. It may be used to answer the question in
box 1 of Figure 20.1.
A seamless drawn steel tube of 500 mm length, 60 mm external diameter and 5 mm wall-
thickness (e.g. according to DIN 2448) should be used, made from steel St 37.0 with tensile strength of 350
to 480 N.mm-2 (e.g. according to DIN 1629). The tube is closed by a malleable cast iron screwing cap or by
an appropriate plastic cap, put over the open end of the tube. The booster consists of a cylindrical pellet
of 50 g RDX/wax (95/5) compressed to a pressure of 1500 bar and with dimensions shown in
Figure 21.4.1.1. The upper part of the booster has an axial recess of 7 mm diameter and 20 mm depth which
accepts a detonator of sufficient strength to initiate the booster reliably. Substances which may react
dangerously with steel St. 37.0 are tested in tubes with an internal polythene coating1.
21.4.1.3 Procedure
21.4.1.3.1 Normally, the steel tube is filled with the substance as received, the sample mass determined
and, if solid, the apparent density calculated using the measured internal tube volume. However, lumps are
crushed and paste-like or gel-type substances are carefully packed to eliminate voids. In all cases, the final
density of the substance in the tube should be as close as possible to its shipping density. The booster is
placed centrally in the upper end of the tube, so that it is surrounded by the substance. When liquids are
tested, the booster is separated from the liquid by wrapping it in a thin foil of aluminium or an appropriate
plastic material. The wrapped booster is then attached to the malleable iron cap by means of thin wires
passing through four additional drillings in the cap. The cap is carefully screwed onto the tube and the
detonator inserted into the booster through the central hole in the screw cap. The detonator is then initiated.
21.4.1.3.2 At least two tests, which may be instrumented (e.g. by a continuous velocity probe), are
performed unless detonation of the substance is observed. An instrumented third test may be necessary if no
conclusion can be drawn from two uninstrumented tests.
(c) If the occasion arises, the measured rate of propagation in the substance.
The test giving the most severe assessment should be used for classification.
1
In special cases, pure aluminium or steel 1.4571 according to DIN 17440 may be used as tube
material.
- 215 -
Copyright © United Nations. All rights reserved
- A velocity measurement shows that the rate of propagation in the non-fragmented part
of the tube is constant and above the velocity of sound in the substance.
"Partial": - The tube is fragmented only at the initiator end and the average tube fragmentation
length (average over two tests) is greater than 1.5 times the average fragmentation
length found with an inert material having the same physical state; and
"No": - The tube is fragmented only at the initiator end and the average fragmentation length
(average of two tests) not more than 1.5 times the average fragmentation length found
with an inert material having the same physical state; and
- 216 -
Copyright © United Nations. All rights reserved
a
Both ends fragmented.
b
Substance completely reacted by deflagration.
c
Detonation velocity 3040 m/s.
- 217 -
Copyright © United Nations. All rights reserved
- 218 -
Copyright © United Nations. All rights reserved
21.4.2.1 Introduction
This test is used to measure the ability of a substance to propagate a detonation by subjecting
it to a detonating booster charge under confinement in a steel tube. It may be used to answer the question in
box 1 of Figure 20.1.
21.4.2.2.1 Solids
The apparatus consists of a seamless steel tube (e.g. material St. 35 in accordance with
DIN 1629/P3), i.d. 50 mm, wall thickness 10 mm, and length 1160 mm (tube type A). At one end (which
will be called the bottom), it is closed by welding a 20 mm-thick steel plate to the tube (see Figure 21.4.2.1).
The tube is instrumented, e.g. by a continuous wire velocity probe, to measure the velocity of propagation in
the substance. The booster charge consists of four RDX/wax (95/5) booster charges of 50 mm diameter,
mass 50 g and length 16.4 mm.
21.4.2.2.2 Liquids
The detonability of liquids is determined with the aid of a tube similar to the tube used for
solids but with a length of 750 mm. One end of the tube (called the bottom) is closed by a 0.5 mm metal
plate under which the four boosters are positioned (tube type B), see Figure 21.4.2.2. The tube is held upright
by means of a holder or three supports welded onto the tube. For corrosive liquids and liquids which
decompose on contact with St. 35, a tube of stainless steel 316 (passivated if necessary) is used with a length
of 750 mm, an internal diameter of 50 mm and an external diameter of 63 mm (tube type C).
21.4.2.3 Procedure
21.4.2.3.1 Solids
The substance should be tested at ambient temperature or at the control temperature, if below
ambient. After fitting the velocity probe, the solid substance under investigation is introduced via the open
end of the tube while the tube is continuously tapped. After filling up to 60 mm below the upper rim of the
tube, the sample mass is determined and the apparent density calculated using the measured internal tube
volume. The four booster charges are inserted, the final booster charge provided with a detonator and the
charge detonated. Two tests are performed unless detonation of the substance is observed.
21.4.2.3.2 Liquids
For tests on liquids the booster charge, which is identical to that used for solids, should be
positioned under the metal plate after which the tube is completely filled with the liquid and its mass
determined. Subsequently, the procedures used for solids and liquids are the same.
21.4.2.4.1 The test results are assessed on the basis of the fragmentation pattern of the tube and, in
some cases, on the measured propagation velocity. The test giving the most severe assessment should be
used for classification.
- 219 -
Copyright © United Nations. All rights reserved
- A velocity measurement shows that the rate of propagation in the non-fragmented part
of the tube is constant and above the velocity of sound in the substance.
"Partial": - In all tests, the substance failed to detonate but the average fragmentation length
(average over two tests) is greater than 1.5 times the average fragmentation length
found with an inert material with the same physical state.
"No": - In all tests, the substance failed to detonate and the average fragmentation length
(average over two tests) is not more than 1.5 times the average fragmentation length
found with an inert material with the same physical state.
a
Performed at the control temperature.
b
Propagation velocity, 660 m/s, greater than the sound velocity in the substance.
c
Propagation velocity, 690 m/s, greater than the sound velocity in the substance.
- 220 -
Copyright © United Nations. All rights reserved
Figure 21.4.2.1: TNO 50/70 STEEL TUBE TEST FOR SOLIDS (TUBE TYPE A)
- 221 -
Copyright © United Nations. All rights reserved
(A) 63.5 (C) or 70 mm (B) outer diameter steel tube (B) Velocity probe
(C) Substance under investigation (D) Steel disc
(E) 4 RDX/wax cartridges (F) Detonator
(G) Supports
Figure 21.4.2.2: TNO 50/70 STEEL TUBE TEST FOR LIQUIDS (TUBE TYPES B AND C)
- 222 -
Copyright © United Nations. All rights reserved
21.4.3.1 Introduction
This test is used to measure the ability of a substance to propagate a detonation by subjecting
it to a detonating booster charge under confinement in a steel tube. It may be used to answer the question in
box 1 of Figure 20.1.
The apparatus is shown in Figure 21.4.3.1. The test sample is contained in cold-drawn,
seamless, carbon steel tube with an external diameter of 48 ± 2 mm, a wall thickness of 4.0 ± 0.1 mm and
a length of 400 ± 5 mm. If the test substance may react with the steel, the inside of the tube may be coated
with fluorocarbon resin. The bottom of the tube is closed with two layers of 0.08 mm thick polythene sheet
pulled tightly (so that it plastically deforms) over the bottom of the tube and held in place with rubber bands
and insulating tape. For samples which affect polythene, polytetrafluoroethylene sheet can be used.
The booster charge consists of 160 g RDX/wax (95/5) or PETN/TNT (50/50), 50 ± 1 mm in diameter with
a density of 1600 ± 50 kg/m3 giving a length of about 50 mm. The RDX/wax charge may be pressed in one
or more pieces, as long as the total charge is within the specifications, and the PETN/TNT charge is cast.
A mild steel witness plate, 150 ± 10 mm square and 3.2 ± 0.2 mm thick, is mounted at the upper end of the
steel tube and separated from it by spacers 1.6 ± 0.2 mm thick.
21.4.3.3 Procedure
21.4.3.3.1 The sample is loaded to the top of the steel tube. Solid samples are loaded to the density
attained by tapping the tube until further settling becomes imperceptible. The sample mass is determined
and, if solid, the apparent density calculated using the measured internal volume of the tube. The density
should be as close as possible to the shipping density.
21.4.3.3.2 The tube is placed in a vertical position and the booster charge is placed in direct contact
with the sheet which seals the bottom of the tube. The detonator is fixed in place against the booster charge
and initiated. Two tests should be performed unless detonation of the substance is observed.
21.4.3.4.1 The test results are assessed on the basis of the fragmentation pattern of the tube. The
witness plate is used only to provide supplemental information on the violence of the reaction. The test
giving the most severe assessment should be used for classification.
"Partial": - The tube is not fragmented over its entire length but the average tube fragmentation
(average over the two tests) is greater than 1.5 times the average fragmentation length
found with an inert material with the same physical state.
"No": - The tube is not fragmented over its entire length and the average tube fragmentation
(average over the two tests) is not more than 1.5 times the average fragmentation
length found with an inert material with the same physical state.
- 223 -
Copyright © United Nations. All rights reserved
- 224 -
Copyright © United Nations. All rights reserved
- 225 -
Copyright © United Nations. All rights reserved
21.4.4.1 Introduction
This test is used to measure the ability of a substance to propagate a detonation by subjecting
it to a detonating booster charge under confinement in a steel tube. It may be used to answer the question in
box 1 of Figure 20.1.
The apparatus is shown in Figure 21.4.4.1 and is identical for solids and liquids. The test
sample is contained in cold-drawn, seamless, carbon steel tube with an external diameter of 60 ± 1 mm, a
wall thickness of 5 ± 1 mm and a length of 500 ± 5 mm. If the test substance may react with the steel, the
inside of the tube may be coated with fluorocarbon resin. The bottom of the tube is closed with two layers of
0.08 mm thick polythene sheet held in place with rubber bands and insulating tape. For samples which affect
polythene, polytetrafluoroethylene sheet can be used. The booster charge is a 200 g RDX/wax (95/5) or
PETN/TNT (50/50), 60 ± 1 mm in diameter and about 45 mm long with a density of 1600 ± 50 kg/m3.
The RDX/wax charge may be pressed in one or more pieces as long as the total charge is within the
specifications and the PETN/TNT charge is cast. The tube may be instrumented, e.g. by a continuous wire
velocity probe, to measure the velocity of propagation in the substance. Additional information on the
explosive behaviour of the test sample can be gained by the use of a witness plate, as shown in
Figure 21.4.4.1. The mild steel witness plate, 150 mm square and 3.2 mm thick, is mounted at the upper end
of the tube and separated from it by spacers 1.6 mm thick.
21.4.4.3 Procedure
The sample is loaded to the top of the steel tube. Solid samples are loaded to the density
attained by tapping the tube until further settling becomes imperceptible. The sample mass is determined
and, if solid, the apparent density calculated. The density should be as close as possible to the shipping
density. The tube is placed in a vertical position and the booster charge is placed in direct contact with the
sheet which seals the bottom of the tube. The detonator is fixed in place against the booster charge and
initiated. Two tests should be performed unless detonation of the substance is observed.
(b) If the occasion arises, the measured rate of propagation in the substance.
The test giving the most severe assessment should be used for classification.
"Partial": - The tube is not fragmented over its entire length but the average tube fragmentation
(average over the two tests) is greater than 1.5 times the average fragmentation length
found with an inert material with the same physical state.
"No": - The tube is not fragmented over its entire length and the average tube fragmentation
(average over the two tests) is not more than 1.5 times the average fragmentation
length found with an inert material with the same physical state.
- 226 -
Copyright © United Nations. All rights reserved
- 227 -
Copyright © United Nations. All rights reserved
- 228 -
Copyright © United Nations. All rights reserved
SECTION 22
TEST SERIES B
22.1 Introduction
Test series B comprises a test and criteria concerning the propagation of detonation of a
substance as packaged for transport. The test is required only for substances which propagate detonation
(box 1 of Figure 20.1).
The question "Can it detonate as packaged for transport?" (box 2 of Figure 20.1) is answered
on the basis of the results of the test method in Table 22.1.
a
Recommended test.
22.2.2 The test is required only for substances for which the answer to the question in box 1 of
Figure 20.1 is "Yes".
22.3.1 The test from series B should be applied to packages (not larger than 50 kg) of substance in
the condition and form in which they are offered for transport.
22.3.2 The preliminary procedure should be performed before performing these tests
(see section 20.3).
- 229 -
Copyright © United Nations. All rights reserved
22.4.1.1 Introduction
This test is used to measure the ability of a substance to propagate a detonation when
packaged as for transport. It involves subjecting the substance in a package to the shock from a detonating
booster charge. It is used to answer the question in box 2 of Figure 20.1.
A detonator, detonating cord, plastic explosive and suitable confining material are required.
A mild steel sheet of about 1 mm thickness, with a minimum size in each direction of 0.2 m larger than that
of the bottom dimensions of the package, serves as a witness plate beneath the package.
22.4.1.3 Procedure
The test is applied to packed substances in the condition and form in which they are offered
for transport. The package is placed on the steel witness plate from which the edges are supported by bricks
or other suitable material so that there is sufficient free air space below the witness plate that puncture is not
impeded. Two charges of plastic explosive (each maximum 100 g but in total not more than 1% by mass of
the substance in the package) are placed on top of the substance in the package. For liquids, metal-wire
support may be needed to ensure that the two explosive charges are located correctly in the middle of each of
the two semicircular or triangular parts of the top surface (see Figure 22.4.1.1). Each charge is initiated by
the detonator through a detonating cord. Both pieces of detonating cord should be of equal length.
The preferred method of confinement is loose sand placed around the test package with a minimum thickness
of 0.5 m in every direction. Alternative methods of confinement are to use boxes, bags or drums filled with
earth or sand placed around and on top of the package with the same minimum thickness. The test is
performed in duplicate unless a detonation is observed. An instrumented third test may be necessary if no
conclusion can be drawn from two uninstrumented tests.
22.4.1.4.1 The test results are assessed on the basis of evidence of a detonation of the substance under
investigation by:
"Yes": - Formation of a crater at the test site or perforation of the witness plate beneath the
product; both in combination with a disruption and scattering of most of the confining
material; or the propagation velocity in the lower half of the package is constant and is
above the velocity of sound in the substance.
"No": - No formation of a crater at the test site, no perforation of the witness plate beneath the
product, a velocity measurement (if made) shows that the rate of propagation is lower
than the velocity of sound in the substance and, for solids, retrieval of unreacted
substance after the test.
- 230 -
Copyright © United Nations. All rights reserved
a
Performed in duplicate. Detection of detonation by formation of crater.
b
Tests performed in duplicate. Propagation velocity measured instead of using a witness plate.
- 231 -
Copyright © United Nations. All rights reserved
- 232 -
Copyright © United Nations. All rights reserved
SECTION 23
TEST SERIES C
23.1 Introduction
Test series C comprises laboratory tests and criteria concerning propagation of deflagration
as requested in boxes 3, 4 and 5 of Figure 20.1.
23.2.1 The question "Does it propagate a deflagration?" (boxes 3, 4 and 5 of Figure 20.1) is
answered on the basis of the results of the test methods in Table 23.1.
a
Recommended test.
23.2.2 The answer is "Yes, rapidly" if shown to be so by either test. The answer is "Yes, slowly" if
the deflagration test result is "Yes, slowly" and the time/pressure test result is not "Yes, rapidly". The answer
is "No" if the deflagration test result is "No" and the time/pressure test is not "Yes, rapidly".
23.3.1 The preliminary procedure (see section 20.3) should be carried out before performing
these tests.
- 233 -
Copyright © United Nations. All rights reserved
23.4.1.1 Introduction
This test is used to measure the ability of a substance1 under confinement to propagate a
deflagration. It may be used to answer the question in boxes 3, 4 and 5 of Figure 20.1.
23.4.1.2.1 The time/pressure apparatus (Figure 23.4.1.1) consists of a cylindrical steel pressure
vessel 89 mm in length and 60 mm in external diameter. Two flats are machined on opposite sides (reducing
the cross-section of the vessel to 50 mm) to facilitate holding whilst fitting the firing plug and vent plug. The
vessel, which has a bore of 20 mm diameter, is internally rebated at either end to a depth of 19 mm and
threaded to accept 1" British Standard Pipe (BSP). A pressure take-off, in the form of a side-arm, is screwed
into the curved face of the pressure vessel 35 mm from one end and at 90° to the machined flats. The socket
for this is bored to a depth of 12 mm and threaded to accept the 1/2" BSP thread on the end of the side-arm.
A washer is fitted to ensure a gas-tight seal. The side-arm extends 55 mm beyond the pressure vessel body
and has a bore of 6 mm. The end of the side-arm is rebated and threaded to accept a diaphragm type pressure
transducer. Any pressure-measuring device may be used provided that it is not affected by the hot gases or
decomposition products and is capable of responding to rates of pressure rise of 690 to 2070 kPa in not more
than 5 ms.
23.4.1.2.2 The end of the pressure vessel furthest from the side-arm is closed with a firing plug which is
fitted with two electrodes, one insulated from and the other earthed to the plug body. The other end of
the pressure vessel is closed by an aluminium bursting disk 0.2 mm thick (bursting pressure
approximately 2200 kPa) held in place with a retaining plug which has a 20 mm bore. A soft lead washer is
used with both plugs to ensure a good seal. A support stand (Figure 23.4.1.2) holds the assembly in the
correct attitude during use. This comprises a mild steel base plate measuring 235 mm × 184 mm × 6 mm and
a 185 mm length of square hollow section (S.H.S.) 70 × 70 × 4 mm.
23.4.1.2.3 A section is cut from each of two opposite sides at one end of the length of S.H.S. so that a
structure having two flat sided legs surmounted by an 86 mm length of intact box section results. The ends of
these flat sides are cut at an angle of 60° to the horizontal and welded to the base plate.
23.4.1.2.4 A slot measuring 22 mm wide × 46 mm deep is machined in one side of the upper end of the
base section such that when the pressure vessel assembly is lowered, firing plug end first, into the box
section support, the side-arm is accommodated in this slot. A packing piece of steel 30 mm wide and 6 mm
thick is welded to the lower internal face of the box section to act as a spacer. Two 7 mm thumb screws,
tapped into the opposite face, serve to hold the pressure vessel firmly in place. Two 12 mm wide strips
of 6 mm thick steel, welded to the side pieces abutting the base of the box section, support the pressure
vessel from beneath.
23.4.1.2.5 The ignition system consists of an electric fusehead of the type commonly used in low
tension detonators, together with a 13 mm square piece of primed cambric. Fuseheads with equivalent
properties may be used. Primed cambric consists of a linen fabric coated on both sides with a potassium
nitrate/silicon/sulphurless gunpowder pyrotechnic composition2.
23.4.1.2.6 The procedure for the preparation of the ignition assembly for solids starts with separation of
the brass foil contacts of an electric fusehead from its insulator, (see Figure 23.4.1.3). The exposed portion of
insulation is then cut off. The fusehead is then fixed onto the terminals of the firing plug by means of
1
When testing liquids, variable results may be obtained because the substance may give two pressure
peaks.
2
Obtainable from the national contact for test details in United Kingdom (see Appendix 4).
- 234 -
Copyright © United Nations. All rights reserved
the brass contacts such that the tip of the fusehead is 13 mm above the surface of the firing plug. A 13 mm
square piece of primed cambric is pierced through the centre and positioned over the attached fusehead
around which it is then folded and secured with fine cotton thread.
23.4.1.2.7 For liquids samples, leads are fixed onto the contact foils of the fusehead. The leads are then
threaded through an 8 mm length of 5 mm o.d. and 1 mm i.d. silicone rubber tubing and the tubing is pushed
up over the fusehead contact foils as shown in Figure 23.4.1.4. The primed cambric is then wrapped around
the fusehead and a single piece of thin PVC sheathing, or equivalent, is used to cover the primed cambric and
the silicone rubber tubing. The sheathing is sealed in position by twisting a length of thin wire tightly round
the sheathing and rubber tubing. The leads are then fixed onto the terminals of the firing plug such that the
tip of the fusehead is 13 mm above the surface of the firing plug.
23.4.1.3 Procedure
23.4.1.3.1 The apparatus assembled, complete with pressure transducer but without the aluminium
bursting disk in position, is supported firing plug end down. 5.0 g3 of the substance is introduced into the
apparatus so as to be in contact with the ignition system. Normally no tamping is carried out when filling the
apparatus unless it is necessary to use light tamping in order to get the 5.0 g charge into the vessel. If, even
with light tamping, it is impossible to get all the 5.0 g of sample in, then the charge is fired after filling the
vessel to capacity. Note should be taken of the charge weight used. The lead washer and aluminium bursting
disk are placed in position and the retaining plug is screwed in tightly. The charged vessel is transferred to
the firing support stand, bursting disk uppermost, which should be contained in a suitable, armoured fume
cupboard or firing cell. An exploder dynamo is connected to the external terminals of the firing plug and the
charge is fired. The signal produced by the pressure transducer is recorded on a suitable system which allows
both evaluation and a permanent record of the time/pressure profile to be achieved (e.g. transient recorder
coupled to a chart-recorder).
23.4.1.3.2 The test is carried out three times. The time taken for the pressure to rise from 690 kPa
to 2070 kPa above atmospheric is noted. The shortest time interval should be used for classification.
23.4.1.4.1 The test results are interpreted in terms of whether a gauge pressure of 2070 kPa is reached
and, if so, the time taken for the pressure to rise from 690 kPa to 2070 kPa gauge.
"Yes, rapidly": - The time for a pressure rise from 690 kPa to 2070 kPa is less than 30 ms.
"Yes, slowly": - The time for a pressure rise from 690 kPa to 2070 kPa is greater than or equal
to 30 ms.
NOTE: If necessary, the deflagration test, Test C.2, should be performed to distinguish between "Yes,
slowly" and "No".
3
If preliminary safety-in-handling tests (e.g. heating in a flame) or [burning] tests (e.g. a series 3
type (d) test) indicate that a rapid reaction is likely to occur, then the sample size should be reduced
to 0.5 g until the severity of the confined reaction is known. If it is necessary to use a 0.5 g sample size, the
sample size is gradually increased until either a "Yes, rapidly" result is obtained or the test is performed
with a 5.0 g sample.
- 235 -
Copyright © United Nations. All rights reserved
a
No ignition.
- 236 -
Copyright © United Nations. All rights reserved
60°
60°
- 237 -
Copyright © United Nations. All rights reserved
60°
- 238 -
Copyright © United Nations. All rights reserved
- 239 -
Copyright © United Nations. All rights reserved
(A) Fusehead
(B) PVC sheath
(C) Insulating card
(D) Silicone rubber tubing
(E) Firing leads
(F) Foil contacts
(G) Wire to make liquid-tight seal
(H) Primed cambric
- 240 -
Copyright © United Nations. All rights reserved
23.4.2.1 Introduction
This test is used to measure the ability of a substance to propagate a deflagration. It may be
used to answer the question in boxes 3, 4 and 5 of Figure 20.1.
23.4.2.2.1 The test is performed with a Dewar vessel (see Figure 23.4.2.1) which is provided with
vertical observation windows on opposite sides. A timer with an accuracy of 1 second is used to measure the
deflagration rate.
23.4.2.2.2 The Dewar vessel has a volume of about 300 cm3, an internal diameter of 48 ± 1 mm, an
external diameter of 60 mm and a length between 180 and 200 mm. The half-time of cooling with 265 cm3 of
water in the Dewar vessel, closed by a cork, should be longer than 5 hours. Horizontal graduation marks are
drawn at 50 and 100 mm from the top of the Dewar vessel. The time it takes for the decomposition front to
propagate from the 50 mm mark to the 100 mm mark yields the deflagration rate. A glass thermometer with
an accuracy of 0.1 °C is used to measure the temperature of the test substance prior to ignition. Alternatively,
the deflagration rate and sample temperature may be determined by using two thermocouples at distances
of 50 mm and 100 mm from the top of the Dewar vessel.
23.4.2.2.3 Any gas flame with a flame length of at least 20 mm can be used for igniting the substance.
23.4.2.3 Procedure
23.4.2.3.1 If preliminary safety-in-handling tests (e.g. heating in a flame) or a small scale burning
test (e.g. the series 3 type (d) test) indicate that a rapid reaction is likely to occur, exploratory tests in
borosilicate glass tubes should be performed, with suitable safety precautions, prior to the Dewar vessel
test. In this case, it is recommended that the test be performed in a 14 mm diameter tube first and
subsequently in a 28 mm diameter tube. If the deflagration rate in any of these exploratory tests
exceeds 5 mm/s, the substance can forthwith be classified as a rapidly deflagrating substance and the main
test, using a Dewar vessel, can be omitted.
23.4.2.3.2 The Dewar vessel and the substance are brought to the emergency temperature as defined in
the Model Regulations. If the substance is sufficiently stable as to require no emergency temperature, a test
temperature of 50 °C is used. The Dewar vessel is filled with 265 cm3 of the substance. Granular substances
are filled into the Dewar vessel in such a way that the bulk density of the substance will be comparable with
that in transport and there are no lumps.
23.4.2.3.3 Pasty materials are introduced into the Dewar vessel in such a way that no air pockets will be
present in the sample to be tested. The height of filling should be about 20 mm below the rim of the Dewar
vessel. The mass and the temperature of the substance are recorded. The Dewar vessel is placed in the test-
cell or fume-chamber behind a shield, after which the substance is heated at the top by means of a gas
burner. At the moment when ignition is observed or, alternatively, if no ignition occurs within five minutes,
the gas burner is removed and extinguished. The period of time that is required for the reaction zone to pass
the distance between the two marks is measured with the timer. If the reaction stops before reaching the
lower mark, the substance is considered to be non-deflagrative. The test is performed in duplicate and the
shortest time interval is used for the calculation of the deflagration rate. Alternatively, the rate may be
determined by locating thermocouples down the centre of the Dewar at distances 50 mm and 100 mm from
- 241 -
Copyright © United Nations. All rights reserved
the top of the Dewar vessel. The thermocouple outputs are monitored continuously. The passage of the
reaction front causes a steep increase in output. The time between the increases in output is determined.
23.4.2.4.1 The test results are interpreted in terms of whether a reaction zone will propagate downwards
through the substance and, if so, the rate of propagation. The participation of oxygen from the air in the
reaction at the sample surface is negligible after the reaction zone has propagated over a distance of 30 mm.
The reaction zone will extinguish if the substance does not deflagrate under the test conditions. The
propagation velocity of the reaction zone (deflagration rate) is a measure of the susceptibility of the
substance to deflagration under atmospheric pressure.
"Yes, slowly": - the deflagration rate is less than or equal to 5.0 mm/s and greater than or equal
to 0.35 mm/s.
"No": - the deflagration rate is less than 0.35 mm/s or the reaction stops before reaching
the lower mark.
NOTE: The time/pressure test, test C.1, is carried out if "Yes, rapidly" is not obtained.
- 242 -
Copyright © United Nations. All rights reserved
a
Pulsating flame followed by extinguishing of flame; no stable propagation under test conditions.
b
Performed with an exploratory test using a glass tube with a diameter of 14 mm at 20 °C instead
of 50 °C.
- 243 -
Copyright © United Nations. All rights reserved
- 244 -
Copyright © United Nations. All rights reserved
SECTION 24
TEST SERIES D
24.1 Introduction
Test series D comprises a test and criteria concerning the propagation of a rapid deflagration
of a substance as packaged for transport. The test is required for substances which deflagrate rapidly in a
series C test.
24.2.1 The question "Does it deflagrate rapidly in package?" (box 6 of Figure 20.1) is answered on
the basis of the results of the test method in Table 24.1.
a
Recommended test.
24.2.2 The test is only required for substances for which the answer from the series C test is "Yes,
rapidly".
24.3.1 The test of series D should be applied to packages (not larger than 50 kg) of substance in the
condition and form in which they are offered for transport.
24.3.2 The preliminary procedure (see section 20.3) should be carried out before performing
these tests.
- 245 -
Copyright © United Nations. All rights reserved
24.4.1.1 Introduction
This test is used to measure the ability of a substance to rapidly propagate a deflagration
when packaged as for transport. It may be used to answer the question in box 6 of Figure 20.1.
An igniter just sufficient to ensure ignition of the substance (e.g. a squib with maximum 2 g
of a slow burning pyrotechnic composition wrapped in thin plastics foil) and suitable confining material are
required.
24.4.1.3 Procedure
The test is applied to packaged substances in the condition and form in which they are
offered for transport. The package is placed on the ground and the igniter is placed in the centre of the
substance. For liquids, a support of metal wires may be needed to fix the igniter in the desired place. The
igniter should be protected against the liquid. The test is performed under confinement. The preferred
method of confinement is loose sand placed around the test package with a minimum of 0.5 m in every
direction. Alternative methods of confinement are to use boxes, bags or drums filled with earth or sand
placed around and on top of the package with the same minimum thickness. The test is performed in
triplicate, unless an explosion is observed. If no deflagration is observed after ignition, the package should
not be approached for at least 30 minutes. It is recommended that a thermocouple be inserted near the
igniter to allow monitoring of its operation and to check when it is safe to approach the package.
24.4.1.4.1 The test results are assessed on the basis of the evidence of a rapid deflagration of the
substance under investigation by:
"Yes" : - Fragmentation of inner or outer packaging into more than three pieces (excluding the
bottom and top parts of the packaging) shows that the substance under investigation
deflagrated rapidly in that package.
"No" : - No fragmentation or a fragmentation of the inner or outer packaging into not more
than three pieces (excluding the bottom and top parts of the packaging) shows that the
substance under investigation did not deflagrate rapidly in that package.
- 246 -
Copyright © United Nations. All rights reserved
- 247 -
Copyright © United Nations. All rights reserved
Copyright © United Nations. All rights reserved
SECTION 25
TEST SERIES E
25.1 Introduction
25.1.1 Test series E comprises laboratory tests and criteria concerning the determination of the
effect of heating under defined confinement as requested in boxes 7, 8, 9 and 13 of Figure 20.1.
25.2.1 The question "What is the effect of heating it under defined confinement?" (boxes 7, 8, 9
and 13 of Figure 20.1) is answered on the basis of combinations of the results from the test methods in
Table 25.1.
a
Recommended test for self-reactive substances in combination with one of the other tests.
b
Recommended test for organic peroxides in combination with one of the other tests.
25.2.2 The combination of the Koenen test and either the Dutch pressure vessel or USA pressure vessel
test should be used for self-reactive substances. The combination of the Dutch pressure vessel test and either
the Koenen test or the USA pressure vessel test should be used for organic peroxides. For classification, the
highest hazard rating should be applied.
25.3.1 The preliminary procedure (see section 20.3) should be carried out before performing these
tests.
- 249 -
Copyright © United Nations. All rights reserved
25.4.1.1 Introduction
This test is used to determine the sensitiveness of substances to the effect of intense heat
under high confinement. It may be used, in conjunction with an additional heating under confinement test, to
answer the question in boxes 7, 8, 9 and 13 of Figure 20.1.
25.4.1.2.1 The apparatus consists of a non-reusable steel tube, with its re-usable closing device,
installed in a heating and protective device. The tube is deep drawn from sheet steel of suitable quality.
The mass of the tube is 25.5 ± 1.0 g. The dimensions are given in Figure 25.4.1.1. The open end of the tube
is flanged. The closing plate with an orifice, through which the gases from the decomposition of the test
substance escape, is made from heat-resisting chrome steel and is available with the following diameter
holes: 1.0 - 1.5 - 2.0 - 2.5 - 3.0 - 5.0 - 8.0 - 12.0 - 20.0 mm. The dimensions of the threaded collar and the nut
(closing device) are given in Figure 25.4.1.1.
25.4.1.2.2 Heating is provided by propane, from an industrial cylinder fitted with pressure regulator, via
a flow meter and distributed by a manifold to the four burners. Other fuel gases may be used provided the
specified heating rate is obtained. The gas pressure is regulated to give a heating rate of 3.3 ± 0.3 K/s when
measured by the calibration procedure. Calibration involves heating a tube (fitted with a 1.5 mm orifice
plate) filled with 27 cm3 of dibutyl phthalate. The time taken for the temperature of the liquid (measured with
a 1 mm diameter thermocouple centrally placed 43 mm below the rim of the tube) to rise from 135 °C
to 285 °C is recorded and the heating rate calculated.
25.4.1.2.3 Because the tube is likely to be destroyed in the test, heating is undertaken in a protective
welded box, the construction and dimensions of which are given in Figure 25.4.1.2. The tube is suspended
between two rods placed through holes drilled in opposite walls of the box. The arrangement of the burners
is given in Figure 25.4.1.2. The burners are lit simultaneously by a pilot flame or an electrical ignition
device. The test apparatus is placed in a protected area. Measures should be taken to ensure that the burner
flames are not affected by any draughts. Provision should be made for extracting any gases or smoke
resulting from the test.
25.4.1.3 Procedure
25.4.1.3.1 Normally substances are tested as received although in certain cases it may be necessary to
test the substance after crushing it. For solids, the mass of material to be used in each test is determined using
a two-stage dry run procedure. A tared tube is filled with 9 cm3 of substance and the substance tamped1
with 80 N force applied to the total cross-section of the tube. If the material is compressible then more is
added and tamped until the tube is filled to 55 mm from the top. The total mass used to fill the tube to
the 55 mm level is determined and two further increments, each tamped with 80 N force, are added. Material
is then either added, with tamping, or taken out as required to leave the tube filled to a level 15 mm from the
top.
A second dry run is performed, starting with a tamped increment a third of the total mass found in the first
dry run. Two more of these increments are added with 80 N tamping and the level of the substance in the
tube adjusted to 15 mm from the top by addition or subtraction of material as required. The amount of solid
determined in the second dry run is used for each trial filling being performed in three equal increments, each
1
For reasons of safety, e.g. the substance is friction sensitive, the substance need not be tamped. In
cases where the physical form of the sample can be changed by compression or compression of the sample is
not related to the transport conditions, e.g. for fibrous materials, more representative filling procedures may
be used.
- 250 -
Copyright © United Nations. All rights reserved
compressed to 9 cm3 by whatever force is necessary. (This may be facilitated by the use of spacing rings.)
Liquids and gels are loaded into the tube to a height of 60 mm taking particular care with gels to prevent the
formation of voids. The threaded collar is slipped onto the tube from below, the appropriate orifice plate is
inserted and the nut tightened by hand after applying some molybdenum disulphide based lubricant. It is
essential to check that none of the substance is trapped between the flange and the plate, or in the threads.
25.4.1.3.2 With orifice plates from 1.0 mm to 8.0 mm diameter, nuts with an orifice of 10.0 mm
diameter should be used; if the diameter of the orifice is above 8.0 mm, that of the nut should be 20.0 mm.
Each tube is used for one trial only. The orifice plates, threaded collars and nuts may be used again provided
they are undamaged.
25.4.1.3.3 The tube is placed in a rigidly mounted vice and the nut tightened with a spanner. The tube is
then suspended between the two rods in the protective box. The test area is vacated, the gas supply turned on
and the burners lit. The time to reaction and duration of reaction can provide additional information useful in
interpreting the results. If rupture of the tube does not occur, heating is continued for at least five minutes
before the trial is finished. After each trial the fragments of the tube, if any, should be collected and weighed.
Examples for the effect types "D", "E" and "F" are shown in Figure 25.4.1.3. If a trial results in any of the
effects "O" to "E", the result is regarded as "no explosion". If a trial gives the effect "F", "G" or "H", the
result is evaluated as "explosion".
25.4.1.3.5 The series of trails is started with a single trial using an orifice plate of 20.0 mm. If, in this
trial, the result "explosion" is observed, the series is continued with trials using tubes without orifice plates
and nuts but with threaded collars (orifice 24.0 mm). If at 20.0 mm "no explosion" occurs, the series is
continued with single trials using plates with the following orifices 12.0 - 8.0 - 5.0 - 3.0 - 2.0 - 1.5 and
finally 1.0 mm until, at one of these diameters, the result "explosion" is obtained. Subsequently, trials are
carried out at increasing diameters, according to the sequence given in 25.4.1.2.1, until only negative results
in three tests are obtained at the same level. The limiting diameter of a substance is the largest diameter of
the orifice at which the result "explosion" is obtained. If no "explosion" is obtained with a diameter
of 1.0 mm, the limiting diameter is recorded as being less than 1.0 mm.
2
The upper part of the tube remained in the closing device is counted as one fragment.
- 251 -
Copyright © United Nations. All rights reserved
"Low": - The limiting diameter is equal to or less than 1.0 mm and the effect in any test is
different from type "O".
"No": - The limiting diameter is less than 1.0 mm and the effect in all tests is of type "O".
a
At the limiting diameter.
b
With a sample mass of 13 g the limiting diameter is < 1.0 mm
- 252 -
Copyright © United Nations. All rights reserved
(A) Nut (b = 10.0 or 20.0 mm) with flats for size 41 spanner
(B) Orifice plate (a = 1.0 → 20.0 mm diameter)
(C) Threaded collar
(D) Flats for size 36 spanner
(E) Flange
(F) Tube
- 253 -
Copyright © United Nations. All rights reserved
- 254 -
Copyright © United Nations. All rights reserved
- 255 -
Copyright © United Nations. All rights reserved
25.4.2.1 Introduction
This test is used to determine the sensitiveness of substances to the effect of intense heat
under defined confinement. It may be used, in conjunction with an additional heating under confinement test,
to answer the question in boxes 7, 8, 9 and 13 of Figure 20.1.
Figure 25.4.2.1 shows the apparatus used. The vessel is made of stainless steel, type
AISI 316. 8 aperture discs are used, the diameters of the orifices being: 1.0 - 2.0 - 3.5 - 6.0 - 9.0 - 12.0 - 16.0
and 24.0 mm. These discs have a thickness of 2.0 mm ± 0.2 mm. The bursting discs are 38 mm diameter
aluminium discs rated to burst at 620 ± 60 kPa at 22 °C (see Figure 25.4.2.2).
The pressure vessel is heated by technical-grade butane taken from a cylinder fitted with a
pressure regulator. A Teclu burner is used. Other gases may be used, with a suitable burner, provided that a
heating rate of 3.5 ± 0.3 K/s is obtained. The heating rate should be checked by heating 10 g of dibutyl
phthalate in the pressure vessel and measuring its temperature. The time taken for the temperature of the oil
to rise from 50 °C to 200 °C is recorded and the heating rate calculated.
25.4.2.3 Procedure
25.4.2.3.1 For a normal test, 10.0 g of the substance should be placed in the vessel. The bottom of the
vessel should be evenly covered with the substance. The 16.0 mm orifice plate is used first. The bursting
disc, central orifice plate and retaining ring are then put in place. The wing nuts are tightened by hand and
the box nut with a spanner. The bursting disc is covered by enough water to keep it at a low temperature. The
pressure vessel is placed on a tripod (with an inside ring diameter of 67 mm) which is inside a protective
cylinder. The ring at the middle of the vessel rests on the tripod.
25.4.2.3.2 The burner is lit, the flow of gas is set to the required rate and the flow of air adjusted so that
the colour of the flame is blue and the inner cone of the flame light blue. The tripod should be of such a
height that the inner cone just touches the bottom of the vessel. The burner is then placed under the vessel
through an opening in the protective casing. The test area should be very well ventilated and entry
prohibited during the test. The vessel is observed from outside the test area either by mirrors or by an
aperture in the wall fitted with armoured glass. The time to reaction and duration of reaction can provide
additional information useful in interpreting the results. Finally the receptacle is cooled in water and cleaned.
25.4.2.3.3 If there is no rupture of the disc with a 16.0 mm orifice, experiments are performed in
sequence with the diameters 6.0, 2.0 and 1.0 mm (one experiment at each diameter) until rupture of the disc
occurs. In cases where no disc rupture is observed with an orifice of 1.0 mm, the next test with an orifice
of 1.0 mm is carried out with 50.0 g of the substance instead of 10.0 g. If still no rupture of the disc is
observed the experiment is repeated until three successive experiments without rupture are obtained. In the
event of rupture of the disc, the experiments are repeated at the next higher level (10 g instead of 50 g or next
higher diameter of the orifice) until the level is found at which there are no ruptures in three successive
experiments.
25.4.2.4.1 The relative degree of sensitivity of a substance to heating in a pressure vessel is expressed
by the limiting diameter. This being the orifice with the largest diameter in millimetres with which, in three
- 256 -
Copyright © United Nations. All rights reserved
tests, the bursting disc is broken at least once, while having remained unbroken during three tests with the
next larger diameter.
"Violent": - Rupture of the disc with an orifice of 9.0 mm or greater and a sample mass of 10.0 g.
"Medium": - No rupture of the disc with an orifice of 9.0 mm but rupture of the disc with an orifice
of 3.5 mm or 6.0 mm and a sample mass of 10.0 g.
"Low": - No rupture of the disc with an orifice of 3.5 mm and a sample mass of 10.0 g but
rupture of the disc with an orifice of 1.0 mm or 2.0 mm and a sample mass of 10.0 g
or rupture of the disc with an orifice of 1.0 mm and a sample mass of 50.0 g.
"No": - No rupture of the disc with an orifice of 1.0 mm and a sample mass of 50.0 g.
a
Test carried out with a 50 g sample.
- 257 -
Copyright © United Nations. All rights reserved
- 258 -
Copyright © United Nations. All rights reserved
- 259 -
Copyright © United Nations. All rights reserved
25.4.3.1 Introduction
This test is used to determine the sensitiveness of substances to the effect of intense heat
under defined confinement. It may be used, in conjunction with an additional heating under confinement test,
to answer the question in boxes 7, 8, 9 and 13 of Figure 20.1.
(a) Test-vessel: 316 stainless steel cylindrical pressure vessel (see Figure 25.4.3.1);
(e) Rupture discs: 38 mm aluminium rupture discs rated 620 ± 50 kPa at 22 °C;
(f) 2 mm thick orifice plates with the following orifice diameters (mm): 1.0, 1.2, 2.0, 3.0,
3.5, 5.0, 6.0, 8.0, 9.0, 12.0, 16.0 and 24.0.
25.4.3.3 Procedure
25.4.3.3.1 The general assembly of the apparatus is shown in Figure 25.4.3.1. The heating rate should
be checked by heating 5.0 g of dibutyl phthalate in a sample cup in the pressure vessel and measuring the
temperature of the dibutyl phthalate. The time taken for the temperature of the dibutyl phthalate to rise
from 50 °C to 200 °C is recorded and the heating rate calculated. The heating rate should be 0.5 ± 0.1 K/s.
An orifice plate, with an orifice diameter larger than the expected vent needed to cause rupture, is selected
and inserted into the side port.
25.4.3.3.2 A 5.0 g sample of the substance to be tested is weighed accurately into an aluminium cup.
The cup is than lowered and positioned with the aid of forceps in the centre of the pressure vessel. The
rupture disc is positioned and secured tightly by the flange bolts. Water is poured over the rupture disc to
keep the disc relatively cool. The heating is switched on to the correct setting at least 30 minutes prior to the
start of the test. The test-vessel is inserted into the pressure vessel holder onto the heater. This plate holder
prevents the test-vessel from falling over. It also prevents escaping vent vapours from reaching the hot plate.
The time to decomposition is noted.
25.4.3.3.3 If the disc does not rupture, the experiment is repeated using a smaller orifice diameter until
rupture of the disc occurs. In the event of a rupture of the disc, the experiment is repeated at the next higher
diameter of the orifice until the level is found at which there are no ruptures in three successive experiments.
25.4.3.4.1 The smallest orifice diameter which does not cause a rupture disc to burst during
decomposition is designated as the USA-PVT number. This value is used as a measure of the effects of
heating a substance under defined confinement. USA-PVT ratings for all substances are based on the same
test conditions and heating rate.
- 260 -
Copyright © United Nations. All rights reserved
25.4.3.4.2 The effect of heating under confinement of the substance is defined by the following criteria:
a
Intermediate diameters, no longer used.
- 261 -
Copyright © United Nations. All rights reserved
- 262 -
Copyright © United Nations. All rights reserved
(A) Shield
(B) Thermal insulation
(C) Sample cup
(D) Electrical heater
(E) Base
(F) Laboratory jack
- 263 -
Copyright © United Nations. All rights reserved
Copyright © United Nations. All rights reserved
SECTION 26
TEST SERIES F
26.1 Introduction
26.1.1 Test series F comprises laboratory tests and criteria concerning the explosive power of
substances as requested in box 12 of Figure 20.1. It is applicable to those substances which are being
considered for transport in Intermediate Bulk Containers (IBCs) or tank-containers or for exemption from the
provisions for self-reactive substances of Division 4.1 or organic peroxides of Division 5.2 (see box 11 of
Figure 20.1). Substances not being considered for these may be assigned to type E without further testing.
26.1.2 All the tests, except test F.5, may also be used for those substances which are being screened
for their ability to propagate detonation (see 21.2.2).
The question "What is its explosive power?" (box 12 of Figure 20.1) is answered on the basis
of the results of one of the test methods in Table 26.1.
a
Recommended test.
26.3.1 The preliminary procedure (see section 20.3) should be performed before carrying out
these tests.
26.3.2 The results obtained in tests F.1 to F.4 depend on the sensitivity to detonative shock of the
substance and the strength of the detonator used. If the results are much lower than those obtained with
similar substances, a more powerful initiation system may be used with a suitable adjustment (e.g. by firing
with inert samples) to the test criteria.
26.3.3 The tests should be performed at ambient temperature. However, if the control temperature is
below ambient temperature, adequate safety precautions should be taken. If the substance is transported
under temperature control as a solid but is liquid at ambient temperature then the test should be performed
just below the melting point.
- 265 -
Copyright © United Nations. All rights reserved
26.4.1.1 Introduction
This test is used to measure the explosive power of a substance. A detonator is initiated in
the substance whilst the substance is confined in the bore of a mortar. The recoil (swing) of the mortar is
measured and, after allowing for the effect of the detonator, the power is calculated as a percentage
equivalence of picric acid - the explosive standard. The test may be used to answer the question in box 12 of
Figure 20.1.
26.4.1.2.1 The mortar consists of a steel tube 457 mm long by 203 mm external diameter, closed at one
end and having a bore 229 mm long with an internal diameter of 25 mm, flaring out at the open end. The
mortar is suspended by 4 stainless steel cables attached at either end by bottle screws and pivots, thus
allowing it to swing freely. The total weight is approximately 113.2 kg and the suspension length
is 2,080 mm. A pen, secured at the extremity of a hinged trailing arm attached to the mortar, scribes on a
horizontal table a line equal to the horizontal swing of the mortar. The mortar body is made in two pieces, an
outer casing of mild steel and an inner cylinder of Vibrac V30 steel heat-treated to a proof stress of 772 MPa.
This cylinder is held in place by a retaining annular plate (Figure 26.4.1.1).
26.4.1.2.2 The sand used for stemming is clean, dry, quartz sand sieved to pass a BS 600 micron sieve
and to be retained on a BS 250 micron sieve. The picric acid is in the form of pure, dry crystals sieved in the
same manner. Boric Acid (analytical grade) is sieved to pass a BS 500 micron sieve. Charge bags are
cylindrical, 25 mm in diameter and made of thin paper. The inner charge bag is 90 mm long and the outer
charge bag 200 mm long.
26.4.1.2.3 The detonator used is a flat-based aluminium sheathed detonator containing 0.6 g PETN.
26.4.1.3 Procedure
26.4.1.3.1 Impact, friction and electric spark tests are normally carried out on the substance before it is
tested in the mortar. 10.00 ± 0.01 g of the substance is tamped into the inner charge bag. The detonator is
inserted into a 6 mm cavity made in the substance with a phosphor-bronze rod and the neck of the bag is
twisted around the detonator. The charge is then inserted in the outer bag and pressed down to the bottom
with a special tool. 57 g of sieved sand is poured into the outer bag and gently compacted by tapping. The
neck of the outer bag is twisted around the detonator wires and the whole charge is inserted into the bore of
the mortar and rammed with the special tool. The detonator is fired and the total horizontal swing (S) is
measured. The test is performed three times and the average swing (Sm) for the substance calculated.
26.4.1.3.2 Liquids are tested by using a cylindrical glass vessel1 of approximately 16 ml volume instead
of the paper charge bag. The open end of the vessel is reduced to a narrow tube 8 mm in diameter and 8 mm
in length. The standard detonator sheathed in a suitable length of polythene tubing makes a push fit seal in
the neck of the vessel. The vessel is then inserted into the outer charge bag, as for solids.
26.4.1.3.3 The picric acid standard value and the detonator standard value established with paper
charge bags may be employed in the power equivalence calculation for liquids fired in glass vessels.
26.4.1.3.4 When a new inner cylinder is inserted into the outer casing of the mortar, the mean swing
(average of 10 shots) given by boric acid (Bm) and picric acid (Pm) are found.
1
The use of glass vessels with powerful explosives can damage the mortar liner. Test firings with
picric acid in glass vessels caused severe wear but produced the same results as picric acid fired in paper
charge bags.
- 266 -
Copyright © United Nations. All rights reserved
"Not Low": - Explosive power values of 7 % or greater of that given by picric acid.
"Low": - Explosive power values of less than 7 % of that given by picric acid but more
than 1 % of that given by picric acid.
- 267 -
Copyright © United Nations. All rights reserved
- 268 -
Copyright © United Nations. All rights reserved
26.4.2.1 Introduction
This test is used to measure the explosive power of a substance. A detonator is initiated in
the substance whilst the substance is confined in the bore of a mortar by a steel projectile. The recoil of the
mortar is measured and the power is calculated as a percentage equivalence of picric acid - the explosive
standard. The test may be used to answer the question in box 12 of Figure 20.1.
26.4.2.2.1 Mortar
The mortar is made of chrome-nickel steel with a mass of 248.50 ± 0.25 kg. It is cylindrical
and the axial cavity consists, from front to rear, of the projectile holder, the firing chamber and access for the
detonator lead wires. The dimensions of the mortar will change during use (in particular, the firing chamber
is enlarged) resulting in diminished recoil with the firing of a given charge. The reference charge used
is 10.00 g picric acid (see 26.4.2.2.7). The used mortar is replaced by a new one when the average energy
released in the last 10 firings is less than 90 per cent of the average energy produced in the first 10 firings
(for similar temperatures and using a projectile in good condition).
The mortar is suspended by steel arms from a roller-bearing mounted horizontal axis. The
mortar pendulum is rendered ballistic by attaching a steel weight underneath it. Figure 26.4.2.1 is a
representation of the ballistic mortar-pendulum, which has the following principal characteristics:
A cursor on the graduated sector displaced by a lateral arm attached to the mortar is used to measure the
recoil. The scale marked on the sector is proportional to (1 - cos A), A being the angle of recoil of the
pendulum, i.e. proportional to the work performed.
26.4.2.2.3 Projectile
The projectile is a steel cylinder. The diameters (diameter 127 mm, length 162 mm) are in
practice adjusted to meet the following conditions:
(a) The gap between the projectile, when new, and its housing in the mortar should be less
than 0.1 mm;
(b) The mass of the projectile, when new, should be 16.00 ± 0.01 kg.
A worn projectile should be replaced when the gap between it and its housing in the mortar
exceeds 0.25 mm. On firing, the projectile is normally expelled at a speed of between 100 and 200 km/h. The
use of a receptacle lined with shock absorbing material enables it to be stopped without being damaged.
When liquids are tested, glass ampoules of 16 g mass with a filling orifice and a recess
to take the detonator (see Figure 26.4.2.3) are used to contain the test samples. Other substances (solid,
granular, pastes, etc.) are loaded in cylindrical sample vessels, 20 mm in diameter, made of tinfoil of
thickness 0.03 mm and mass about 2 g. This applies, for instance, to picric acid charges.
- 269 -
Copyright © United Nations. All rights reserved
26.4.2.2.5 Supports
A steel-wire ring support with three feet, shown in Figure 26.4.2.2, is used to centre the
charge in the firing chamber (to reduce wear on the mortar).
26.4.2.2.6 Detonators
These are European standard detonators charged with 0.6 g PETN, as shown in Appendix 1.
This is pure crushed picric acid, grain size less than 0.5 mm, dried at 100 °C and kept in a
tightly-stoppered flask.
26.4.2.3 Procedure
26.4.2.3.1.1 Compact solids have to be tested in the form of cylindrical blocks, diameter 20 mm ± 1 mm,
with at one end an axial cavity (diameter 7.3 ± 0.2 mm, depth 12 mm) to accommodate the detonator.
The mass of the block should be 10.0 ± 0.1 g. To prepare the charge, the block is wrapped in tinfoil,
thickness 0.03 mm, mass approximately 2 g. The detonator is placed in its housing and the end of the foil
wrapping pressed around the head of the detonator (see Figure 26.4.2.3).
26.4.2.3.1.2 Substances other than liquids are packed at normal density in tinfoil wrappings, each test
charge weighing 10.0 ± 0.1 g. The detonator is inserted to a depth of approximately 12 mm in the substance.
The end of the wrapping is twisted around the head of the detonator (see Figure 26.4.2.3).
26.4.2.3.1.3 For liquids, a charge of 10.0 ± 0.1 g of the test substance is placed in a glass ampoule. The
detonator is placed in its housing. If necessary, metal wire can be used to hold it in place (but under no
circumstances combustible material).
26.4.2.3.1.4 Charges of 10.0 ± 0.1 g of picric acid, at normal density, are also prepared in foil wrappings.
The detonator is inserted to a depth of approximately 12 mm in the picric acid. The end of the wrapping is
twisted around the head of the detonator.
26.4.2.3.2.1 The charge, placed in a charge holder (see 26.4.2.2.5) is pressed home in the firing chamber,
the detonator head being in contact with the rear surface of the chamber (see Figure 26.4.2.3).
26.4.2.3.2.2 The projectile is greased with a consistent quality lubricant, inserted and pushed home in its
housing in the mortar. To avoid any scatter in the results, due to possible distortion of the mortar or
projectile, the position of the projectile in relation to the mortar housing is checked and recorded.
26.4.2.3.2.3 The cursor (see 26.4.2.2.2) is placed in contact with the moving arm so that the recoil of the
pendulum can be measured. After firing, the deviation (D) of the pendulum is noted, i.e. the point at which
the cursor remains on the graduated sector at the end of the swing.
26.4.2.4 Procedure
26.4.2.4.1 Four firings are first carried out with picric acid. The average of the four deviations obtained
is calculated. This average should have a value around 100, in the arbitrary unit of power adopted for the
scale of the sector on which the pendulum recoil is measured. The results of the four firings should not vary
- 270 -
Copyright © United Nations. All rights reserved
by more than one unit, and if that is the case, the value Do will be the average of the four deviations
measured. If one of the results varies by more than one unit from the average, it is discarded and the value Do
is the average of the other three results.
26.4.2.4.3 The procedure is then repeated with the test substance, for not less than three firings, the
deviations obtained being D1, D2, D3 etc. The corresponding powers, expressed as a percentage of the finding
for picric acid, are calculated by the equation:
26.4.2.4.4 The average value of Tk is then calculated. The result, rounded to the nearest whole number,
is called the "ballistic mortar power" (BMP) of the substance.
NOTE: When several substances are to be tested in succession during the same half-day, only one series of
four firings with picric acid is made in the half-day.
26.4.2.5.1 The result of the test is presented in detail by giving the results T1, T2, T3 ... and the value of
BMP and the ambient temperature. In summary form, only the BMP value is given.
- 271 -
Copyright © United Nations. All rights reserved
- 272 -
Copyright © United Nations. All rights reserved
- 273 -
Copyright © United Nations. All rights reserved
(A) To igniter
(B) Detonator
(C) 20 mm diameter charge
(D) Charge holder
(E) Firing chamber
(F) Projectile
(G) Expanded view of charge holder
- 274 -
Copyright © United Nations. All rights reserved
- 275 -
Copyright © United Nations. All rights reserved
26.4.3.1 Introduction
This test is used to measure the explosive power of a substance. A detonator is initiated in
the substance whilst the substance is confined in a hole in a lead block. The explosive power is expressed in
the form of the increase in volume of the cavity in the lead block per 10 g of substance. The test may be used
to answer the question in box 12 of Figure 20.1.
26.4.3.2.1 Initiation of the substance is achieved by a European standard detonator with 0.6 g of PETN
(see Appendix 1).
26.4.3.2.2 For the test, standardized Trauzl lead blocks of cylindrical shape are used with a height
of 200 mm and a diameter of 200 mm. They have an axial recess of 25 mm diameter and 125 mm depth with
a volume of 61 cm3, see Figure 26.4.3.1. The lead blocks are made by casting pure soft lead into moulds at a
casting temperature of 390 °C to 400 °C. The quality of a casting series of lead blocks is checked by three
test explosions each using 10 cm3 of crystallized picric acid (loading density 1.0 g/cm3). The mean of the
three net expansion values obtained should be between 287 cm3 and 300 cm3.
26.4.3.3 Procedure
26.4.3.3.1 Solid substances are shaped to cylindrical test charges with a volume of 10 cm3 by wrapping
in a weighed piece of tinfoil and the mass of the charge determined. The test charges have an external
diameter of 24.5 mm, a height of 22.2 mm, and a coaxial recess of 7 mm diameter and 12 mm depth to take
the detonator. The test charge is prepared in a device consisting of a piston, a two-part matrix, a clamping
frame and a base piece (Figure 26.4.3.2). For this, a trapezoidal piece of tinfoil (thickness approx. 0.01 mm)
55 m wide is wound round the piston. The die with its tinfoil sheath is then introduced into the matrix until it
reaches the backstop of the base. The matrix is clamped with the aid of the frame and the piston is slowly
drawn out of the tinfoil tube after pressing it firmly against the base piece. The bottom of the tinfoil tube is
carefully pierced in its centre using a thin wooden rod. From the side of the clamping frame, the standard
detonator PETN 0.6 g is inserted into the base piece so that the detonator wires are drawn through the hole in
the adjusting screw until the detonator touches the screw. The screw is so adjusted that the detonator
projects 12.0 mm from the base piece. The substance to be tested is put into the tinfoil tube, compressing it
lightly by means of a wooden rod. The projecting tinfoil edge is folded inwards and the piston is pressed into
the matrix up to the collar. After withdrawing the piston, the prepared test charge, in the tinfoil tube, with the
inserted detonator, is carefully taken out of the matrix.
26.4.3.3.2 Liquid substances are tested in thin-walled glass cylinders of similar shape and of such a
capacity as to take the sample volume of 10 cm3 and that of the detonator, when it is introduced to a depth of
12 mm into the liquid. The neck of the vessel is of such a length that it keeps the detonator in a central
position. After having determined the sample mass, the test charge is carefully introduced into the recess of
the lead block right to the bottom. The lead blocks are stored in a temperature-controlled room, so that the
temperature, measured in the depth of the recess, immediately before introducing the charge, is in the
range 10 °C and 20 °C. For the test, the lead block should rest on a flat, massive support of steel laid on the
ground. For stemming, the remaining space in the recess is filled with dry quartz sand, passed through a
sieve of 144 meshes per cm2, with a gravimetric density of 1.35 g/cm3. The lead block is then hit at the side
three times with a hammer of 2 kg mass and the excess of sand is removed from the upper surface.
- 276 -
Copyright © United Nations. All rights reserved
26.4.3.3.3 The detonator is fired and the block emptied of any residues. The volume of the enlarged
cavity is measured using water and the expansion which would be caused by a 10 g sample calculated using
the expression:
26.4.3.3.4 Normally, the test is conducted in duplicate and the highest expansion value obtained used
for the assessment.
26.4.3.4.1 The explosive power is expressed in the form of the increase in volume of the cavity in the
lead block per 10 g of substance. At a given strength of initiation, the explosive power increases with the
volume of expansion.
"Not Low": - The expansion of the lead block is 25 cm3 or more per 10 g of sample.
"Low": - The expansion of the lead block is less than 25 cm3 but more than or equal to 10 cm3
per 10 g of sample.
"No": - The expansion of the lead block is less than 10 cm3 per 10 g of sample.
- 277 -
Copyright © United Nations. All rights reserved
a
Determined by using test charges of 11 cm3 volume and a slightly stronger test blasting cap with a
copper tube of 6.85 mm external diameter and 45 mm length, with flat bottom containing 0.5 g PETN
with 10% wax, 0.2 g tetryl, and 0.5 g mercury fulminate as explosive charge, all pressed at 400 bar.
b
Initiation with 3 detonators gives 123 cm3/10 g, Not low
- 278 -
Copyright © United Nations. All rights reserved
- 279 -
Copyright © United Nations. All rights reserved
(A) End part of piston for preparing the tinfoil tube (B) Piston
(C) Test sample (D) Detonator
(E) Adjusting screw (axial bore 3.5 mm, slot 1 mm, 100 mm long) (F) Base piece
(G) Pins (H) Clamping frame
(J) Matrix (K) Knurled screw
(L) Tin foil
Figure 26.4.3.2: DEVICE FOR MAKING THE CHARGES (10 cm3 volume, 24.6 mm
diameter and 22.2 mm height) FOR THE BAM TRAUZL TEST
- 280 -
Copyright © United Nations. All rights reserved
26.4.4.1 Introduction
This test is used to measure the explosive power of a substance. A detonator is initiated in
the substance whilst the substance is confined in a hole in a lead block. The explosive power is expressed in
the form of the average increase in volume of the cavity in the lead block over the value obtained from an
inert substance with similar physical properties. The test may be used to answer the question in box 12 of
Figure 20.1.
The lead block is machined from cast or extruded lead rod 50 ± 1 mm diameter by 70 mm
long with a cavity 25.4 mm in diameter and 57.2 mm long as shown in Figure 26.4.4.1. The cavity is cut with
a flat-tipped drill to prevent puncture of the lead block. The blasting cap used is a standard No. 8 (USA)
detonator (see Appendix 1). Assembly A is used for liquids and pastes and assembly B for solids
(see Figure 26.4.4.2). The sample vial used for assembly A is a commercial 12 ml, 21 mm o.d. vial. The
sample vial used for assembly B is a commercial 16 ml, 24.9 mm o.d. vial. The polyethylene stoppers are the
standard ones supplied with the vials. The glass tube used to locate the blasting cap in assemblies A and B is
a borosilicate glass culture tube. It is 10 mm o.d. × 75 mm long. A 10 mm diameter hole drilled in the centre
of the polyethylene stopper gives a tight fit which holds the tube secure. Two rubber "0" rings (16.5 mm i.d.,
2.5 mm diameter cross section) are used to centre the vial in the cavity in the lead block in assembly A.
26.4.4.3 Procedure
A 6.0 g sample is placed in the sample vial which is assembled as required and placed in the
lead block. The lead block is placed on a solid surface in a protected area, the blasting cap is fully inserted
and, when the area is vacated, the cap is fired. The volume of the cavity in the lead block is measured
accurately, to the nearest 0.2 ml, using water before and after the test. Three tests are conducted on the
substance and on the inert reference substance using the same type of assembly.
26.4.4.4.1 The explosive power of the test sample is expressed in terms of the average increase of the
volume of the cavity in the lead block over that given by the inert reference substance.
"Not low": - The average net block expansion is equal to or greater than 12 cm3.
"Low": - The average net block expansion is less than 12 cm3 but greater than 3 cm3.
- 281 -
Copyright © United Nations. All rights reserved
Air 6
Dimethyl phthalate 10
Mineral spirits 10.5
Paste of 60% CaCO3 + 40% dimethyl phthalate 8
Water 10
Air 5.5
Benzoic acid 7
Calcium carbonate (powder) 5
Kaolin clay 6
a
Performed at ambient temperature.
- 282 -
Copyright © United Nations. All rights reserved
- 283 -
Copyright © United Nations. All rights reserved
26.4.5.1 Introduction
This test is used to measure the specific energy of a substance. Varying quantities of substance
are heated in a sealed vessel and the maximum pressure rise obtained for each sample size measured.
The specific energy is a function of the maximum pressure rise. The test may be used to answer the question
in box 12 of Figure 20.1.
26.4.5.2 Apparatus
The high pressure autoclave (Figure 26.4.5.1) is a cylindrical stainless steel vessel with a
capacity of 96 ml and a working pressure of 150 MPa at a temperature of 473 K. The vessel is made from
stainless steel type AISI 431, has an internal diameter of 38 mm and an internal height of 84 mm. An inner
sample vessel (stainless steel type AISI 316, internal diameter 32 mm and internal height 77 mm) is used
inside the autoclave. A coated Ni/Cr resistance wire (specific resistance of approximately 10 ohms/m), skip-
wound around a piece of glass tube, is used to heat the sample by means of a constant current supply;
a heating power of 50-150 W is supplied. Owing to the use of the inner vessel, the heat transfer from the
substance to the autoclave is relatively small compared to the heat transfer that would exist in the situation
without inner vessel. Therefore rapid heating will take place which will lead to an exothermic reaction
involving self-heating and explosion. The pressure-time history of the explosion is determined. The pressure
is registered by means of a piezo-electric transducer.
26.4.5.3 Procedure
The required amount of substance is weighed into the sample vessel after which the sample
vessel is placed in the autoclave. The heating coil is connected to the lid of the autoclave which is then
closed. Provisions are made to ensure that the whole heating coil is completely immersed in the substance.
The ends of the heating wire are then connected to the power supply electrodes by low-resistance wire.
The sample is then heated until explosion occurs. Experiments are normally performed using 5, 10, 15, 20
and 25 g of substance and the maximum pressure recorded. However, these quantities may need to be varied
according to the bulk density and detonability of the substance.
26.4.5.4.1 The results are assessed on the basis of the specific energy (F) which is a function of the
maximum pressure rise (Pm). The initial sample mass (Mo) and the volume (V) of the reaction vessel are
required to calculate the specific energy using the following equation:
V/Mo = F/Pm + C
Where V = internal volume of pressure vessel - volume of steel of inner sample vessel;
C = constant under the test conditions; and
F = determination from the slope of the plot of V/Mo versus 1/Pm.
The explosive power of a substance is based on the value of the specific energy F only.
- 285 -
Copyright © United Nations. All rights reserved
- 286 -
Copyright © United Nations. All rights reserved
(A) Valve
(B) Pressure transducer
(C) Autoclave
(D) Inner sample vessel
(E) Electrodes
- 287 -
Copyright © United Nations. All rights reserved
Copyright © United Nations. All rights reserved
SECTION 27
TEST SERIES G
27.1 Introduction
27.1.1 Test series G comprises tests and criteria concerning the determination of the effect of a
thermal explosion of a substance as packaged for transport, requested in box 10 of Figure 20.1. The test is
only needed for substances which show a violent effect in tests involving heating under defined confinement
(test series E).
27.2.1 The question "Can it explode as packaged for transport?" (box 10 of Figure 20.1) is
answered on the basis of the results of one of the test methods in Table 27.1.
a
Recommended test.
27.2.2 Both tests are considered equivalent for all substances excluding water-wetted solids. For
water-wetted solids, in the event that the results of the two tests are not in agreement, the results of test G.1
have precedence over the results of test G.2.
27.3.1 The test of Series G should be applied to packages of substance (not more than 50 kg) in the
condition and form in which they are offered for transport.
27.3.2 The preliminary procedure (see section 20.3) should be performed before carrying out
these tests.
- 289 -
Copyright © United Nations. All rights reserved
27.4.1.1 Introduction
This test is used to determine the potential for thermal explosion in a package. It may be
used to answer the question in box 10 of Figure 20.1.
27.4.1.2.1 Packaging (not larger than that needed for 50 kg of substance), substance, a suitable heating
device (e.g. 2 kW for 25 kg of substance) and equipment for measuring temperatures.
27.4.1.3 Procedure
The test is applied to packed substances in the condition and form in which they are offered
for transport. The method of obtaining the thermal explosion is by heating the substance as homogeneously
as possible with an electric heating coil within the package. The surface temperature of the heating coil
should not be so high that premature ignition of the substance can take place. It may be necessary to use
more than one heating coil. The package should be mounted on a stand to keep it upright. The heating system
is switched on and the temperature of the substance continuously recorded. The heating rate should be
about 60 °C/hour. The difference in temperature between the substance at the top and bottom of the package
should be as small as possible. It is advisable to make provision in advance for the remote destruction of
the package in the event of heater failure. The test is performed in duplicate unless an explosion is
observed.
27.4.1.4.1 Observations are made on the evidence of an explosion of the package under investigation
by fragmentation of the package. The results obtained are only valid for the package tested.
"Yes": - A fragmentation of inner and/or outer packaging(s) into more than three pieces
(excluding bottom and top parts of the packaging(s) show(s) that the substance under
investigation can give an explosion of that package.
"No": - No fragmentation or a fragmentation into not more than three pieces shows that the
substance under investigation does not explode in the package.
- 290 -
Copyright © United Nations. All rights reserved
a
N.F. means no fragmentation.
- 291 -
Copyright © United Nations. All rights reserved
27.4.2.1 Introduction
This test is used to determine the potential for thermal explosion in a package. It may be
used to answer the question in box 10 of Figure 20.1.
The equipment for this test is a typical SADT test cell as represented in Figure 27.4.2.1 and
as described for test H.1 in section 28.
27.4.2.3 Procedure
The test is carried out in accordance with the procedure described for test H.1 in section 28.
The temperature of the test cell may be set approximately 10 °C above the SADT, if known. The SADT test
cell is designed to readily vent any significant pressure developed during the decomposition of a test sample.
The cell covers are simply set in place and held by gravity alone.
27.4.2.4.1 The condition of the sample, the package, the test cell, and the immediate surroundings
provide a measure of the violence of the decomposition reaction of the product/package configuration tested.
27.4.2.4.2 The test criteria are defined in terms of the condition of the test cell, the package and the
occurrence of an explosion and are as follows:
"Yes": - Significant disruption of the inside of the test cell would be noted. The outer cover
may be lifted off and carried at least two metres indicating significant internal cell
pressure. The test package would be severely damaged, breaking into at least three
fragments.
"No": - Slight to no disruption of the test cell. The outer cover may be lifted off but not carried
further than two meters from the cell. The test package may be disrupted and damaged
e.g. split inner packaging, torn carton.
- 292 -
Copyright © United Nations. All rights reserved
- 293 -
Copyright © United Nations. All rights reserved
- 294 -
Copyright © United Nations. All rights reserved
SECTION 28
TEST SERIES H
28.1 Introduction
This test series contains test methods for the determination of the self-accelerating
decomposition temperature (SADT). The SADT is defined as the lowest temperature at which self-
accelerating decomposition may occur with a substance in the packaging as used in transport. The SADT is a
measure of the combined effect of the ambient temperature, decomposition kinetics, package size and the
heat transfer properties of the substance and its packaging. To assist in interpreting the results, models can be
used in which the main resistance to heat flow is:
The text should be used in conjunction with the temperature control requirements given in sub-
section 2.5.3.4 of the Model Regulations.
28.2.1 Test series H comprises tests and criteria concerning the thermal stability of substances at
transport temperatures or concerning the determination of whether a substance meets the definition of a self-
reactive substance.
28.2.2 Each test involves either storage at a fixed external temperature and observation of any
reaction initiated or storage under near adiabatic conditions and measurement of the rate of heat generation
versus temperature. The test methods included in test series H are given in Table 28.1. Each of the methods
listed is applicable to solids, liquids, pastes and dispersions.
a
Recommended test for substances transported in packagings.
b
Recommended test for substances transported in packagings, IBCs or tanks.
c
Recommended test for substances transported in packagings, IBCs or small tanks.
The list of tests is not exhaustive; other tests may be used provided that they give the correct SADT of the
substance as packaged for transport.
- 295 -
Copyright © United Nations. All rights reserved
28.2.3 When necessary (SADT ≤ 50 °C for organic peroxides, SADT ≤ 55 °C for self-reactive
substances), control and emergency temperatures may be derived from the SADT using Table 28.2.
a
i.e. the SADT of the substance as packaged for transport.
28.2.5 The results obtained for the largest commercial package are applicable to smaller packages
of similar construction and material provided that the heat transfer per unit mass is no smaller than from the
larger package.
28.3.1 The preliminary procedure (see section 20.3) should be performed and the effect of heating
under confinement (test series E) determined before performing SADT tests. Safety precautions should be
taken which allow for the possibility of catastrophic failure of the test vessel and for the hazards arising
from the ignition of secondary fuel-air mixtures and the evolution of toxic decomposition products.
Substances liable to detonate should only be tested with special precautions.
28.3.2 The test selected should be conducted in a manner which is representative, both in size and
material, of the package to be transported. For transport in metal packagings, IBCs or tanks, it may be
necessary to include a representative amount of the metal in the sample tested i.e. representative of both the
metal(s) and the area of contact.
28.3.3 Extra care should be taken when handling samples which have been tested since changes
may have occurred rendering the substance more unstable and more sensitive. Tested samples should be
destroyed as soon as possible after the test.
28.3.4 Samples which have been tested at a particular temperature and are apparently unreacted
may be used again, for screening purposes only, provided extra care is taken. Fresh samples should be used
for the actual determination of the SADT.
28.3.5 If the complete package is not tested, the heat loss data used for the determination of the
SADT should be representative of the package, IBC or tank offered for transport. The heat loss per unit of
mass of the package, IBC or tank may be determined by calculation (taking account of the quantity of
substance, dimensions of the package, heat transfer in the substance and the heat transfer through the
packaging to the environment) or by measuring the half-time of cooling of the package filled with the
substance or another substance having similar physical properties. The heat loss per unit mass, L (W/kg.K),
- 296 -
Copyright © United Nations. All rights reserved
can be calculated from the half-time of cooling, t1/2 (s), and the specific heat, Cp (J/kg.K), of the substance
using the formula:
L = ln 2 × Cp / t1/2.
28.3.6 The half-time of cooling can be determined by measuring the period of time in which the
temperature difference between the sample and surroundings is decreased by a factor of 2. For example, for
liquids, the packaging may be filled with dibutyl phthalate or dimethyl phthalate and this heated to
about 80 °C. Water should not be used as erratic results may be obtained through evaporation / condensation.
The temperature drop is measured at the centre of the package over the temperature range which includes the
expected SADT. For scaling, it may be necessary continuously to monitor the temperature of the substance
and surroundings and then use linear regression to obtain the coefficients of the equation:
ln {T - Ta} = co + c × t
28.3.7 Examples of the heat loss characteristics of some typical packages are given in Table 28.3.
The actual value obtained will depend on the shape, wall thickness, surface coating etc. of the packaging.
Table 28.3: HEAT LOSS PER UNIT MASS FROM PACKAGES, IBCs AND TANKS
For solids:
1G 38 28.0 kg DCHPc 35
c
1G 50 37.0 kg DCHP 29
1G 110 85.0 kg DCHPc 22
c
4G 50 32.0 kg DCHP 27
a
DMP = dimethyl phthalate.
b
Calculated using a heat transfer coefficient of 5 W/m2.K.
c
Dicyclohexyl phthalate (solid).
- 297 -
Copyright © United Nations. All rights reserved
28.4.1.1 Introduction
This method determines the minimum constant temperature air environment at which auto-
accelerative decomposition occurs for a substance in a specific package. Packages of up to 220 litres may be
tested by this method. An indication of the explosion hazard from the decomposition reaction can also be
obtained.
28.4.1.2.1 The test substance and packaging should be representative of that intended for commercial
use. The packaging forms an essential part of the test.
28.4.1.2.2 The apparatus consists of a test chamber in which the air surrounding the package under test
can be maintained at a constant temperature for a period of at least ten days.
(c) The minimum separation distance from the package to the wall is 100 mm.
Any type of oven may be used provided that it is capable of meeting the temperature control requirements
and will not ignite any decomposition products. Examples of a suitable small-package and large-package
oven are given in 28.4.1.2.4 and 28.4.1.2.5 respectively.
28.4.1.2.4 A small-package oven may be constructed from an open head 220 litre steel drum. This will
readily accommodate packages of up to 25 litres capacity. Construction details are shown in Figure 28.4.1.1.
Larger packages may be tested as long as a 100 mm clearance between the package and the oven wall is
maintained.
28.4.1.2.5 An expendable large-package oven may be made from 50 mm × 100 mm lumber formed into
a cubic frame 1.2 m on each side, which is lined inside and out with 6 mm thick waterproof plywood and
insulated all around with 100 mm fibreglass insulation. Construction details are shown in Figure 28.4.1.2.
The frame should be hinged on one side to permit loading and unloading of test drums. The floor should be
provided with 50 mm × 100 mm lumber on edge, spaced 200 mm on centres to keep the test container off the
floor and allow free air circulation around the package. Cleats should run normal to the door to permit a fork-
lift to move the drums. A circulating fan should be located on the side opposite the door. The air flow should
be from the upper corner of oven to the fan discharge at the diagonally opposite lower corner. An electric
heater of 2.5 kW is suitable for heating the air. Thermocouples should be placed in the air intake and outflow
ducts as well as the top, middle and bottom of the oven. For substances with an SADT below ambient
temperature, the test should be performed in a cooling chamber or solid carbon dioxide should be used for
cooling the oven.
28.4.1.2.6 The package should be equipped with a thermowell which positions the thermocouple at the
package mid-point. The thermowell may be constructed of glass, stainless steel or other suitable material but
should be introduced in a manner which does not reduce package strength or venting capability.
28.4.1.2.7 Continuous temperature-measuring and recording equipment, which is protected from fire
and explosion hazards, is required.
- 298 -
Copyright © United Nations. All rights reserved
28.4.1.2.8 The tests should be performed in an area which provides adequate protection from fire
and explosion hazards, and from toxic fumes. A safety distance, e.g. 90 m, from public roads and occupied
buildings is recommended. If there may be toxic fumes, longer safety distances may be required.
28.4.1.3 Procedure
28.4.1.3.1 The package is weighed. A thermocouple is inserted in the package to be tested such that the
temperature in the centre of the sample can be monitored. If the required oven temperature is below ambient,
the oven is switched on and the inside of the oven cooled to the desired temperature before placing the
package in the oven. If the required oven temperature is at or above ambient temperature, the package is
inserted in the oven at ambient temperature and the oven then switched on. There should be a minimum
clearance of 100 mm between the package and the sides of the oven.
28.4.1.3.2 The sample is heated and the temperature of the sample and test chamber continuously
monitored. The time is noted at which the sample temperature reaches a temperature 2 °C below the test
chamber temperature. The test is then continued for a further seven days or until the sample temperature rises
to 6 °C or more above the test chamber temperature if this occurs sooner. Note the time taken for the sample
to rise from the 2 °C below the test chamber temperature to its maximum temperature.
28.4.1.3.3 When the test is completed, cool the sample and remove it from the test chamber. Note the
variation of temperature with time. If the package remains intact, note the percentage mass loss and
determine any changes in composition. Dispose of the sample as soon as possible.
28.4.1.3.4 If the temperature of the sample does not exceed the oven temperature by 6 °C or more then
repeat the test with a new sample in an oven at a 5 °C higher temperature. The self-accelerating
decomposition temperature (SADT) is defined as the lowest oven temperature at which the sample
temperature exceeds the oven temperature by 6 °C or more. If the substance is being tested to determine if
temperature control is necessary, perform sufficient tests to determine the SADT to the nearest 5 °C or to
determine if the SADT is greater than or equal to 60 °C. If the substance is being tested to determine if it
meets the SADT criterion for a self-reactive substance, perform sufficient tests to determine if the SADT for
a 50 kg package is 75 °C or less.
28.4.1.4.1 The SADT is reported as the lowest temperature at which the sample exceeds the oven
temperature by 6 °C or more. If the sample temperature does not exceed the oven temperature by 6 °C or
more in any test, the SADT is recorded as being greater than the highest oven temperature used.
- 299 -
Copyright © United Nations. All rights reserved
- 300 -
Copyright © United Nations. All rights reserved
- 301 -
Copyright © United Nations. All rights reserved
Figure 28.4.1.2: LARGE PACKAGE OVEN (top view and side view)
- 302 -
Copyright © United Nations. All rights reserved
28.4.2.1 Introduction
28.4.2.1.1 This test method determines the rate of heat generation produced by a reacting substance as
a function of temperature. The heat generation parameters obtained are used with the heat loss data relating
to the package to determine the SADT of a substance in its packaging. The method is appropriate for every
type of packaging, including IBCs and tanks.
28.4.2.1.2 Measurements can be performed in the temperature range from -20 °C to 220 °C.
The smallest temperature rise that can be detected corresponds to a rate of heat generation of 15 mW/kg.
The upper limit is determined by the capacity of the cooling system to safely cool the substance (up to 500
W/kg if water is used as the coolant). Although the test is not perfectly adiabatic, the heat losses are less
than 10 mW. The maximum error is 30% at 15 mW/kg and 10% from 100 mW/kg to 10 W/kg.
28.4.2.1.3 If the cooling system is activated at a stage where the rate of heat generation exceeds the
cooling capacity, an explosion may occur. The test site should therefore be carefully selected to reduce to a
minimum the possible hazards from an explosion and of a possible subsequent gas explosion of the
decomposition products (secondary explosion).
28.4.2.2.1 The apparatus consists of a glass Dewar vessel (1.0 or 1.5 litre) to contain the sample,
an insulated oven with a differential control system to keep the temperature in the oven to within 0.1 °C of
the sample temperature and an inert lid for the Dewar vessel. In special cases, sample holders of other
construction materials may have to be used. An inert heating coil and cooling tube pass through the lid into
the sample. Pressure build-up in the Dewar vessel is prevented by a 2 m long PTFE capillary tube which
passes through the insulated lid. A constant power heating unit is used for internal heating of the substance to
a pre-set temperature or for calibration. Internal heating and cooling may be stopped or started automatically
at pre-set temperatures. In addition to the cooling system, a secondary safety device is fitted which
disconnects the power supply to the oven at a pre-set temperature. A schematic drawing of the AST is given
in Figure 28.4.2.1.
28.4.2.2.2 The temperature of the substance is measured at its centre by means of thermocouples or
platinum resistance sensors placed in a steel or glass tube. The temperature of the surrounding air is
measured at the same height as the sample temperature, also with thermocouples or platinum resistance
sensors. Continuous temperature measuring and recording equipment is required to monitor the temperature
of substance and the air in the oven. This equipment should be protected from fire and explosion.
For substances with an SADT below ambient temperature, the test should be performed in a cooling chamber
or solid carbon dioxide should be used for cooling the oven.
28.4.2.3 Procedure
(a) Fill the Dewar vessel with sodium chloride, dibutyl phthalate or with a suitable oil and
place it in the vessel holder of the AST oven;
(b) Heat the sample in 20 °C steps using the internal heating system at a known power
rating, e.g. 0.333 or 1.000 W, and determine the heat losses at 40 °C, 60 °C, 80 °C
and 100 °C;
(c) Use the data to determine the heat capacity of the Dewar vessel using the method
given in 28.4.2.4.
- 303 -
Copyright © United Nations. All rights reserved
(a) Fill the Dewar vessel with the weighed sample, including a representative amount of
packaging material (if metal), and place it in the vessel holder of the AST oven;
(b) Start the temperature monitoring and then increase the sample temperature using the
internal heater to a pre-set temperature at which detectable self-heating may occur.
The specific heat of the substance can be calculated from the temperature rise, heating
time and heating power;
(c) Stop the internal heating and monitor the temperature. If no temperature rise due to
self-heating is observed within 24 hours, increase the temperature by 5 °C. Repeat this
procedure until self-heating is detected;
(d) When self-heating is detected, the sample is allowed to heat up under adiabatic
conditions to a pre-set temperature where the rate of heat generation is less than the
cooling capacity, upon which the cooling system is activated;
(e) On cooling, determine the loss in mass, if any, and determine the change in
composition (if desired).
28.4.2.4.1 Calculate the rate of temperature drop, A ( °C/h), of the Dewar vessel at the different
temperatures used in the calibration procedure. Plot a graph through these values in order to allow
determination of the rate of temperature drop at any temperature.
28.4.2.4.2 Calculate the heat capacity, H (J/ °C), of the Dewar vessel using the formula:
3600 × E 1
H= − (M 1 × Cp 1 )
A+B
A × (H + M 1 × Cp1 )
K=
3600
- 304 -
Copyright © United Nations. All rights reserved
28.4.2.4.4 Calculate the specific heat, Cp2 (J/kg °C) of the substance using:
3600 × (E 2 + K ) H
Cp 2 = −
C × M2 M2
28.4.2.4.5 Calculate the heat generation, QT (W/kg), of the substance at intervals of 5 °C using the
following formula for each temperature:
D
(M 2 × Cp 2 + H ) ×
− K
QT = 3600
M2
28.4.2.4.6 Plot the calculated rates of heat generation per unit of mass as a function of the temperature
in a graph with linear scales and draw the best-fit curve through the plotted points. Determine the heat losses
per unit of mass, L (W/kg °C) of the specific package, IBC or tank (see 28.3.3). Draw a straight line of
gradient L tangential to the heat generation curve. The intersection of the straight line and the abscissa is
the critical ambient temperature i.e. the highest temperature at which the substance as packaged does not
show self-accelerating decomposition. The SADT is the critical ambient temperature ( °C) rounded to the
next higher multiple of 5 °C. An example is given in Figure 28.4.2.2.
- 305 -
Copyright © United Nations. All rights reserved
- 306 -
Copyright © United Nations. All rights reserved
- 307 -
Copyright © United Nations. All rights reserved
28.4.3.1 Introduction
28.4.3.1.1 This method determines the rate of heat generation produced by reacting or decomposing
substances as a function of time at constant temperature. The heat generation parameters obtained are used
with the heat loss data relating to the package to determine the SADT of a substance in its packaging. The
method is appropriate for every type of packaging including IBCs and tanks. Some substances may show an
increase in the rate of heat generation with increasing decomposition (e.g. due to autocatalysis or induced
decomposition). This property is also taken into account by this test method.
28.4.3.1.2 Measurements can be performed in the temperature range of -20 °C to 200 °C. Heat
generation values can be measured from 5 mW/kg to 5 W/kg. The thermal resistance between the sample
holder and aluminium block via the heat flow meters is about 0.1 W/ °C. The apparatus is able to measure
rates of heat generation from 15 mW/kg to 1500 mW/kg with a maximum error of 30% at 15 mW/kg and 5%
from 100 to 1500 mW/kg.
28.4.3.1.3 The robust construction of the apparatus, the relatively small sample size and the well-
defined operating conditions enable the test to be performed in an ordinary laboratory. The effects of a
thermal explosion, e.g. fragmentation of the sample holder and generation of pressure, should be contained
within the apparatus.
28.4.3.2.1 The apparatus consists of an air-insulated heat sink (an aluminium block) which is kept at a
constant temperature by means of controlled heating. A cryostat is used to maintain temperatures
below 40 °C. The heat controller is capable of maintaining the temperature to within 0.2 °C of the set
temperature. The temperature of the heat sink is measured with a platinum-resistance sensor. The two holes
drilled in the block contain heat flow meters (e.g. Peltier elements). A schematic drawing of the IST is given
in Figure 28.4.3.1. For substances with an SADT below ambient temperature, the test should be performed in
a cooling chamber or solid carbon dioxide should be used for cooling the oven.
28.4.3.2.2 Holders are placed on both heat flow meters: one with the sample and one with an inert
substance. Both holders are identical and have a volume of 70 cm3. The amount of substance in each holder
is about 20 g. The holders are made of glass or stainless steel. The steel must be compatible with the test
substance. When using a glass holder, it is provided with a long capillary tube which prevents pressure build-
up in the holder and evaporation of the sample.
28.4.3.2.3 The voltage difference resulting from the difference in heat flow from sample holder to the
heat sink and inert substance holder to the heat sink is continuously recorded as a function of time
(differential measurement) by a recorder or computer.
28.4.3.3 Procedure
Before a measurement can be performed, the blank signal and the sensitivity of the heat flow
meter need to be determined by the following calibration procedure.
(b) Insert a heating coil in the sample holder. Fill the sample and reference holders with
inert material (e.g. sodium chloride or milled glass beads) ensuring that the heating
coil is completely covered with material. Place both holders in the IST;
- 308 -
Copyright © United Nations. All rights reserved
(c) Determine the blank signal (the output of the recorder when no electric power is
applied to the heating coil);
(d) Determine the sensitivity of the heat flow meter using two or three different electrical
heating powers which lie within the expected range of heat generation of the sample to
be tested.
(b) Fill the sample holder with the weighed sample and with a representative quantity of
packaging material (if metal) and insert the holder into the apparatus. The amount of
sample should be sufficient to give a rate of heat generation between 5 mW to 1500
mW per kg of substance;
(c) Start monitoring the rate of heat production. The results from the first 12 hours of the
test should not be used because this period is required for temperature equilibration.
The duration of each test depends on the test temperature and on the rate of heat
production. The test should last for at least 24 hours after the 12 hour equilibration
period but can then be stopped if the rate of heat generation is falling from the
maximum or if the rate of heat generation is greater than 1.5 W/kg;
(d) At the end of the test the change in sample mass should be determined;
(e) The test is repeated with new samples at temperature intervals of 5 °C so that there are
seven results with a maximum heat generation rate between 15 and 1500 mW/kg.
28.4.3.4.1 Calculate the sensitivity, S (mW/mV), of the instrument at the various electrical powers used
in the calibration procedure using the following formula:
P
S=
Ud − Ub
28.4.3.4.2 Use these values and the test data to calculate the maximum rate of heat generation,
Q (mW/kg), at the different test temperatures using the formula:
(U s − U b ) × S
Q=
M
28.4.3.4.3 Plot the calculated maximum rate of heat generation per unit of mass as a function of the test
temperature on a graph with linear scales and draw the best-fit curve through the plotted points. Determine
the heat losses per unit of mass, L (W/kg °C) of the specific package, IBC or tank (see 28.3.3). Draw a
straight line of gradient L tangential to the heat generation curve. The intersection of the straight line and the
- 309 -
Copyright © United Nations. All rights reserved
abscissa is the critical ambient temperature i.e. the highest temperature at which the substance as packaged
does not show self-accelerating decomposition. The SADT is the critical ambient temperature ( °C) rounded
to the next higher multiple of 5 °C. An example is given in Figure 28.4.3.2.
- 310 -
Copyright © United Nations. All rights reserved
- 311 -
Copyright © United Nations. All rights reserved
- 312 -
Copyright © United Nations. All rights reserved
28.4.4.1 Introduction
28.4.4.1.1 This method determines the minimum constant air environment temperature at which
thermally unstable substances undergo exothermic decomposition at conditions representative of the
substance when packaged as for transport. The method is based on the Semenov theory of thermal explosion
i.e. the main resistance to heat flow is considered to be at the vessel walls. The method can be used for
the determination of the SADT of a substance in its packaging, including IBCs and small tanks (up to 2 m3).
28.4.4.1.2 The effectiveness of the method depends on selecting a Dewar vessel with heat loss per unit
mass characteristics similar to the package offered for transport.
28.4.4.2.1 The experimental equipment consists of a suitable test chamber, appropriate Dewar vessels
with closures, temperature probes and measuring equipment.
28.4.4.2.2 The test should be performed in a test cell capable of withstanding fire and overpressure
and, preferably, should be fitted with a pressure relief system e.g. a blow out panel. The recording system
should be housed in a separate observation area.
28.4.4.2.3 For tests at temperatures up to 75 °C, a double walled metal chamber (ca. 250 mm inner
diameter, 320 mm outer diameter and 480 mm high made from 1.5 to 2.0 mm thick stainless steel sheet) is
used with fluid from a temperature-controlled circulating bath passed between the walls at the desired
temperature. The test chamber is loosely closed by an insulated lid (e.g. made from 10 mm thick polyvinyl
chloride). The temperature control should allow the desired temperature for a liquid inert sample in the
Dewar vessel to be maintained with a deviation of not more than ± 1 °C for up to 10 days.
28.4.4.2.4 Alternatively, and particularly for tests at temperatures above 75 °C, a thermostatically
controlled drying oven (which may be fan-assisted) large enough to allow air circulation on all sides of the
Dewar vessel may be used. The air temperature in the oven should be controlled so that the desired
temperature for a liquid inert sample in the Dewar vessel can be maintained with a deviation of not more
than ± 1 °C for up to 10 days. The air temperature in the oven should be measured and recorded. It is
recommended that the door of the oven be fitted with a magnetic catch or replaced by a loosely fitting
insulated cover. The oven may be protected by an appropriate steel liner and the Dewar vessel housed in a
wire mesh cage.
28.4.4.2.5 For tests at sub-ambient temperatures, a double walled chamber (e.g. a freezer) of suitable
size provided with a loose door or lid (e.g. with a magnetic closure) may be used. The temperature of the air
in the chamber should be controlled to ± 1 °C of the set temperature.
28.4.4.2.6 Dewar vessels, with their closure system, are used with heat loss characteristics which are
representative of the maximum size of package offered for transport. The closure of the Dewar vessel should
be inert. Particularly for solids, cork or rubber bungs may used. A closure system for use with liquids with
low or medium volatility is illustrated in Figure 28.4.4.1. Samples which are highly volatile at the test
temperature should be tested in a pressure-tight metal vessel fitted with a pressure relief valve. The pressure
vessel is placed in the Dewar vessel and the effect of the heat capacity of the metal vessel taken into account
by calculation.
28.4.4.2.7 The heat loss characteristics of the system used, i.e. Dewar vessel and closure, should be
established (see 28.3.6) prior to performance of the test. Since the closure system has a significant effect on
the heat loss characteristics, these can be adjusted to some extent by varying the closure system. In order to
achieve the required level of sensitivity, Dewar vessels with sample capacities below 0.5 litres should not be
used.
- 313 -
Copyright © United Nations. All rights reserved
28.4.4.2.8 Dewar vessels, filled with 400 ml of substance, with a heat loss of 80 to 100 mW/kg.K are
normally suitable for representing a 50 kg package. For larger packages, IBCs or small tanks larger Dewar
vessels with lower heat losses per unit mass should be used. For example, spherical 1 litre Dewar vessels
having heat loss characteristics in the range 16 to 34 mW/kg.K may be suitable for IBCs and small tanks.
28.4.4.3 Procedure
28.4.4.3.1 Set the test chamber at the selected storage temperature. Fill the Dewar vessel, to 80% of its
capacity, with the substance under test and note the mass of the sample. Solids should be moderately
compressed. Insert the temperature probe into the centre of the sample. Seal the lid of the Dewar in place and
insert the Dewar vessel in the test chamber, connect the temperature recording system and close the test
chamber.
28.4.4.3.2 The sample is heated and the temperature of the sample and test chamber continuously
monitored. The time is noted at which the sample temperature reaches a temperature 2 °C below the test
chamber temperature. The test is then continued for a further seven days or until the sample temperature rises
to 6 °C or more above the test chamber temperature if this occurs sooner. Note the time taken for the sample
to rise from 2 °C below the test chamber temperature to its maximum temperature.
28.4.4.3.3 If the sample survives, cool and remove it from the test chamber and carefully dispose of it
as soon as possible. The percentage mass loss and change in composition may be determined.
28.4.4.3.4 Repeat the test with fresh samples, varying the storage temperature in 5 °C steps. If the
substance is being tested to determine if temperature control is necessary, perform sufficient tests to
determine the SADT to the nearest 5 °C or to determine if the SADT is greater than or equal to 60 °C. If the
substance is being tested to determine if it meets the SADT criterion for a self-reactive substance, perform
sufficient tests to determine if the SADT for a 50 kg package is 75 °C or less.
28.4.4.4.1 The SADT is reported as the lowest temperature at which the sample undergoes exceeds the
test chamber temperature by 6 °C or more. If the sample temperature does not exceed the test chamber
temperature by 6 °C or more in any test, the SADT is recorded as being greater than the highest storage
temperature used.
- 314 -
Copyright © United Nations. All rights reserved
a
In a pressure vessel contained with a 2 litres Dewar vessel.
b
In a spherical, 1 litre Dewar vessel.
- 315 -
Copyright © United Nations. All rights reserved
(A) PTFE capillary tube (B) Special screw fittings (PTFE or Al) with O-ring seal
(C) Metal strip (D) Glass lid
(E) Glass beaker base (F) Spring
(G) Glass protective tube (H) Dewar vessel
(J) Steel retaining device
- 316 -