Knuerr-DCL
Knuerr-DCL
Business-Critical Continuity™
Knürr® DCL
Modular Rack Cooling from 6kW to 60 kW
Emerson Network Power
Business-Critical Continuity™ – so your success continues!
No company, no matter how big it is, We can ensure the stable operation
Core competencies can afford business-critical system of your network infrastructure – re-
failures. gardless of whether voice, data or
multimedia content are transmitted.
AC Power Over the years we at Emerson Net-
Connectivity work Power have acquired unique This is based on a proven, compre-
know-how, and with our name we hensive portfolio of products, ser-
DC Power
represent reliable rack systems, vices and systems which supports a
Embedded Computing power supply, precision cooling, multitude of computing, telecom-
Embedded Power connectivity and integrated solu- munications, health care and in-
tions. We can consequently ensure dustrial applications. This creates a
Infrastructure Management &
that you generate optimum benefits foundation of trust that is only possi-
Monitoring from your technology investments. ble with a partnership with Emerson
Outside Plant Network Power.
Thanks to Emerson Network Pow-
Power Switching & Controls er's technology range and extensive Our assignment is to prepare you for
Thermal Management competencies, the entire bandwidth the unknown and the unexpected.
of company-wide solutions is sup- We show you the way against the
Racks & Solutions
ported for today's critical business background of dynamic changes in
Services requirements. your business environment.
Surge Protection Customers all over the world build on And we help you to master the re-
our support for future-proof invest- quirements this entails and avail of
ments, because they know that we the greatest possible benefits from
offer globally specific innovations and your technology investments. This
optimized solutions from one single is what we mean by Business-Critical
source – supported by reliable local Continuity.
service and support.
2
Knürr® DCL
Modular Rack Cooling from 6kW to 60kW
4 5
Knürr® DCL-L
Closed Loop Cooling Architecture
Complete separation of IT
equipment and room, precisely
controlled cooling air tempera-
ture
Knürr® DCL-L with one Knürr® DCM *30/34 kW per rack 2-1 combination *15/17 kW per rack
Knürr® DCL30L frontview High Density Server Rack cooled by two *60 kW per rack 4-1 combination *6/7 kW per rack
Knürr® DCL-L
Availability
An essential requirement for data Precise control of cooling air Redundant A/B power supply with
center operators is to ensure un- temperature and air flow control automatic operation
interrupted availability. Knürr through patented concept Dual-circuit heat exchanger option
guarantees this by means of Even air distribution to all internal ensures redundancy of the water
"Fail-safe“ function ("safe despite IT component supply if two independent chilled
faults") of the control valve: in the water circuits are installed
Even temperature profile in the air
event of a power failure or interrup- supply Optional integration into Knürr®
tion in the control line, the control
CoolVac systems guarantees leak
valve switches the full volume of n+1 fan redundancy means that
proofing (patent pending).
the chilled water flow to heat ex- the remaining fans support the
changers. volume flow required for cooling The automatic door opening pro-
Rack cooling controller in the event of a fan failure. vides additional overheating pro-
Rack cooling controller hardware
tection in case of cooling system
guarantees autonomous In the event of
failure.
continued operation of the control - planned downtime or mainte-
in the event of a component nance
failure. Components continue - or unnecessary cooling power,
to operate in a controlled way in non-return values ensure that
"fail-safe" mode. hot air can flow from the hot
aisle into the cold zone of the
Access control and data security
data center.
guaranteed by means of HTTPS
and SNMP V3.
Alarm management can be inte-
Rack cooling controller display output
grated into DCIM (Data Center In-
frastructure Management).
Rack cooling controller imple-
ments the patented concept of
regulating the fan speeds based on
indirect differential pressure mea-
surement.
Rack cooling controller ensures
traceability of all settings changes
by means of login logging and Rack cooling controller architecture
event logging.
Automatic emergency door opening option for Non-return flap open Non-return flap closed
server rack
10 11
Knürr® DCL
Efficiency Adaptability
In today's competition, no Energy cost savings by adjusting Minimum possible investment for Same base unit can be used for
data center operator can leave the fan speed to the actually cooling components through the aisle cooling concepts and rack
the issue of costs untouched. required air flow using the ability to use up to four server racks cooling with minimum conversion
Anyone who only thinks about embedded controller per Knürr® DCL cost.
the upfront costs or wants to cut Low air pressure drop leads to Facilitates data center upgrade Simple switchover between 2-way
costs at the expense of reliability lower power consumption of the through gradual expansion of the and 3-way valve by means of a ball
will be in for unpleasant surprises fans. data center with no new invest- valve in the bypass line
later on. Clever decision-makers ment in different cooling infra-
will consider Knürr experience EC fans guarantee energy-
structure.
in ensuring lower running costs efficient operation with maximum
Simple fan change performance over the entire range
with maximum availability. Can be adapted to different
of fan speeds.
Greater power density in the data geometries
center results in better utilization Operator support through the
- Height 2,000mm and 2,200 mm
of space and reduced building ability to display the "cooling
- Depth in 100mm increments
costs. power" efficiency value (ratio of
from 1,000mm to 1,300mm.
electrical power consumption of
Reduced running costs through the servers to fans)
customized operation. Future-proof cooling solution be-
Fans in Knürr® DCL
High chilled water supply tem- cause Knürr EC fans already comply
perature increases the proportion with the energy efficiency require-
of free cooling during refrigeration ments for CE approval that will
and improves the energy efficiency apply from 2015.
rating (EER) of the chiller. Cooling power and energy effi-
ciency (fan/pump power consump-
The control valve adjusts cold tion for cold water connection)
water volume flow for the current confirmed by independent insti-
operational situation. tutions
Low water-side pressure drop leads
Knürr® DCM server rack for cooling with
to lower pump power consump-
Knürr® DCL, Liebert® power distribution tion.
modules and integrated cable manage-
ment.
12 13
Knürr® DCL
Basic specification, Order table
14 15
As at: August 2013/ Version 1.0
While every precaution has been taken to ensure accuracy and completeness of this
literature, Emerson Network Power and/or its affiliates makes no representations or
warranty about the accuracy, reliability, completeness, or timeliness of the materials
and disclaims any and all liability for damages resulting from use of this information
or for any errors or omissions.
Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. ©2013 Emerson Electric Co.