ARC-FREE ULTRA HIGH-SPEED
DC CIRCUIT BREAKER
CITY ELECTRIC TRANSPORT ■ METRO ■
ABOUT COMPANY
AFB® is an innovative ultra high-speed DC to the main circuit current. The generated
circuit breaker based on PLUTON experience current compensates the main circuit current.
and advanced technologies. AFB® is provided Thus, the main contact opens with a current
for application in tram, trolleybus, light value close to zero, whereby there is no arc
rail and metro traction substations power during currents of any value breaking.
distribution systems.
AFB® stands out for its vacuum interrupter
The main innovation of AFB® is the main increased mechanical/electrical wear
contact operation in vacuum and arc-free resistance, which highly determines the life
current switching principle. Pre-charged cycle of circuit breaker — minimum 25 years
high-voltage capacitor generates current to without necessity of mechanical and electrical
interrupt short-circuit current in antiphase components periodic replacement.
3 х 50 000
SWITCHINGS
LOWEST MAINTENANCE
/ fault currents breaking resource is / built-in line test function increases the
much higher than the one of a circuit circuit breaker service life due to hard
breaker with traditional switching and arc fault closing blocking.
interruption.
Safety Maintenance
/ no plasma emission during short-circuit / no arc chute and, thereby, no need for its
currents breaking due to switching in maintenance;
vacuum interrupter;
/ no need for the main circuit contact
/ no combustion products and their deposits system maintenance during operation,
on the circuit breaker components and on due to absence of combustion products on
the switchgear units; AFB® components;
/ reduction of fire risk due to no open / no need for inspection, maintenance and
plasma formation area during switching; replacement of vacuum interrupter until
the end of its mechanical life along with
/ built-in disconnector ensuring safety of
a large number of switching cycles with
operational switching.
maximum value of short-circuit currents.
Vacuum interrupter
/ no open arc
Disconnector
/ maintenance-free
System functions:
/ all circuit breaker components and parts / output of the system status data and
operation control; measurements for the upper level;
/ provides all data processing intelligent / provides galvanic isolation and pulses
functions; generation for thyristors control.
Measurement module:
I, kA
nearby fault
Imax making
current
di/dt protection
making current
di/dt
t, ms
moment of di/dt protection
setting reaching and tripping Imax
making current
moment of Imax moment of
protection setting Imax protection
reaching setting reaching
moment of Imax
protection tripping
Imax and di/dt
protections operation
AFB®
D
B C
A. Switching vacuum interrupter with the D. The main switching capacitor is rated for
main contact opening and closing control operating voltage 1000 V and is activated by
system. switching via power thyristors. The capacitor
charge is constantly monitored by control
B. The main contact closing control coil is system.
activated by switching via thyristor to a pre-
charged capacitor. E. Built-in line tester. The line is tested
optionally. It can be tested before each
C. The main contact opening control coil is tripping of the circuit breaker.
rated for operating voltage 1000 V and is
activated by switching via thyristor to a pre- F. Reverse diode is provided for load currents
charged capacitor. The capacitor charge is shunting during forward breaking.
constantly monitored by control system.
Before the circuit breaker tripping control The opening coil magnetic field influences
system tests: auxiliaries voltage, high-voltage breaking mechanism, which actuates vacuum
opening and interrupting capacitors voltage, interrupter moving contact, thereby vacuum
interrupting thyristors and shunting diodes interrupter power contacts open.
proper functioning. Closing is possible both
Arc starts between contacts upon their
with preliminary line test and without it.
opening, and is interrupted by power, stored in
pre-charged high-voltage capacitor. Capacitor
Closing
discharge current is switched in antiphase to
Pre-charged low-voltage capacitors battery the main current of power circuit. The arc is
provides circuit breaker closing by closing coil interrupted at the moment, when currents
actuation with closing thyristor. algebraic sum is zero. Afterwards the contacts
open and interrupt power circuit.
Operational breaking
Fault breaking
Circuit breaker control system actuates
opening thyristor on receiving breaking Fault breaking has similar to operational
command. When thyristor opens, the power breaking principle. In this case, the signal
stored in high-voltage opening capacitor is for breaking is measurements from current
switched to opening coil. sensor, installed in the circuit breaker main
power circuit, and processed by AFB® control
system microcontroller according to specified
algorithms.
interrupting
current
line power current interrupting current
I, kA
100
f mode
<25 kA
SHORT-CIRCUIT
CURRENT LIMITING
UNDER PEAK RATED
e, d mode
VALUE
100 kА 25
CONTACTS OPENING t, ms
10 20 30
TIME IS
1 ms
AFB® provides high-speed power contact Power stored in circuit dissipates in load circuit
opening and circuit breaker di/dt tripping upon high inductivity load tripping
before short-circuit current setting reaching. (e, d mode according to EN 50123-2/IEC
Contacts opening time is 1 ms. 61992-2). This eliminates overvoltage and
circuit breaker components wear (under
High-speed electrical circuit tripping under
forward current direction). Power stores
nearby fault (f mode according to EN 50123-2/
in capacitor, or dissipates on resistor upon
IEC 61992-2) leads to current limitation at the
reverse current breaking.
early stage of short circuit growth. This reduces
electrodynamic load on conductive parts. AFB® provides secure low current breaking,
and as a result, circuit breaker contacts
damage prevention.
AFB 25 AFB 40
Voltage
Maximum operating voltage Umax V DC 1000
Insulation voltage UNm V DC 1800
Test impulse voltage UNi kV DC 10
Maximum switching overvoltage. Zone B
acc. to EN50124.2
(<20 ms) V DC <2500 <6000
Current
Rated service current INe А DC 2500 4000
Duty class acc. to IEC 60146-1-1 - VI
Short-circuit current
Steady-state short-circuit current INss kA 80
Peak of the short-circuit current ȊNss kA 100
Maximum breaking current Imax kA 25
Forward current di/dt limit kA/ms 20
Time
Contacts opening time ms <1
Total break time ms <4
Additional data
Commutation life switchings 3 x 50 000
Protection level - IP 00
Auxiliaries supply voltage V DC 110, 220
No damaging thermal and dynamic effect (restriction of the use of certain hazardous
of arc provides increased safety and no substances) directives, and apply materials
contaminating combustion products. with minimum environmental impact in our
production.
PLUTON is certified in concordance with
ISO 14001:2015 international environmental
safety standard. We comply with RoHS