LEGEND
* : optional
Translation can be found in the installation manual.
# : field supply
NOTES to go through before starting the unit Part n° Description
X1M : Main terminal A1P main PCB M1P additional zone pump
X2M : Field wiring terminal for AC A2P * On/OFF thermostat (PC=power circuit) M1S mixing 3 way valve
A3P * heat pump convector M2P # domestic hot water pump
X5M : Field wiring terminal for DC
A4P * digital I/O PCB M2S # 2 way valve for cooling mode
X6M : BUH Power supply terminal A5P bizone PCB M3P main zone pump
A6P current loop PCB M3S 3 way valve for space heating
A8P * demand PCB /domestic hot water
: Earth wiring
A9P status indicator P1M MMI display
: Field supply
A10P MMI PSU PCB PC (A15P) * power circuit
1 : Several wiring possibilities A11P MMI main PCB PHC1 (A4P) * optocoupler input circuit
A12P MMI display PCB Q1L thermal protector backup heater
: Not mounted in switch box
: Option A13P * LAN adapter Q3L, Q4L # safety thermostat
A14P * user interface PCB Q*DI # earth leakage circuit breaker
A15P * receiver PCB (wireless R1H (A2P) * humidity sensor
: PCB On/OFF thermostat)
: Wiring depending on model R1T (A1P) inlet water thermistor
B1L flow sensor R1T (A2P) * ambient sensor On/OFF thermostat
B1PW water pressure sensor R1T (A14P) * ambient sensor user interface
Note 1 : Connection point of the power supply for the BUH should be foreseen outside the unit. CN* (A4P) * connector R2T (A1P) outlet backup heater thermistor
DS1 (A5P) dipswitch R2T (A2P) * external sensor (floor or ambient)
Backup heater 6T1 (3~, 230V, 6kW) DS1 (A8P) * dipswitch R5T, R8T domestic hot water thermistor
power supply 6V (1N~, 230V, 6kW) POSITION IN SWITCH BOX E1H backup heater element (1 kW) R6T * external indoor or outdoor
6WN/9WN (3N~, 400V, 6/9kW) E2H backup heater element (2 kW) ambient thermistor
SWB1 E*P (A9P) indication LED R7T mixed leaving water thermistor
F1B # overcurrent fuse backup heater S1L flow switch
User installed options: LAN adapter F1T thermal fuse backup heater S1S # preferential kWh rate PS contact
TR1
Remote user interface F1U, F2U * fuse 5 A 250 V for digital I/O PCB S2S # electrical meter pulse input 1
X1M X2M (A4P)
X5M S3S # electrical meter pulse input 2
Ext. indoor thermistor
F1U, F2U fuse T 2 A 250 V for PCB S6S-S9S * digital power limitation inputs
Ext. outdoor thermistor A6P (A5P)
A8P SS1 (A4P) * selector switch
Digital I/O PCB FU1 (A1P) fuse T 5 A 250 V for PCB SW1~2 turn buttons
Demand PCB K7M FU2 (A10P) fuse T 1.6 A 250 V for PCB (A12P)
A1P
A5P K1M, K2M contactor backup heater SW3~5
Bottom plate heater A4P push button
K6M K5M safety contactor BUH (A12P)
Main LWT:
K6M relay 3 way valve bypass TR1 power supply transformer
On/OFF thermostat (wired)
K7M relay 3 way valve flow X6M # BUH power supply terminal strip
On/OFF thermostat (wireless) A10P
K*R relay on PCB X*, X*A, J* connector
Ext. thermistor K5M K1M K2M Q1L (A1P, A4P) X*H*, X*Y
Heat pump convector X*M terminal strip
Safety thermostat
SWB2
Add LWT:
On/OFF thermostat (wired)
On/OFF thermostat (wireless)
Ext. thermistor
Heat pump convector