0% found this document useful (0 votes)
19 views1 page

EAVZ-D6V7_wir1_4D120620_1_EN

The document outlines the wiring and component specifications for a heating unit, including various terminal connections, PCB descriptions, and optional user-installed components. It provides detailed notes on installation and safety features, such as backup heaters and thermistors. Additionally, it includes information on power supply connections and configuration options for the system.

Uploaded by

dusseler
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views1 page

EAVZ-D6V7_wir1_4D120620_1_EN

The document outlines the wiring and component specifications for a heating unit, including various terminal connections, PCB descriptions, and optional user-installed components. It provides detailed notes on installation and safety features, such as backup heaters and thermistors. Additionally, it includes information on power supply connections and configuration options for the system.

Uploaded by

dusseler
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

EAVZ-D6V7

LEGEND
* : optional
Translation can be found in the installation manual.
# : field supply
NOTES to go through before starting the unit Part n° Description
X1M : Main terminal A1P main PCB M1P additional zone pump
X2M : Field wiring terminal for AC A2P * On/OFF thermostat (PC=power circuit) M1S mixing 3 way valve
A3P * heat pump convector M2P # domestic hot water pump
X5M : Field wiring terminal for DC
A4P * digital I/O PCB M2S # 2 way valve for cooling mode
X6M : BUH Power supply terminal A5P bizone PCB M3P main zone pump
A6P current loop PCB M3S 3 way valve for space heating
A8P * demand PCB /domestic hot water
: Earth wiring
A9P status indicator P1M MMI display
: Field supply
A10P MMI PSU PCB PC (A15P) * power circuit
1 : Several wiring possibilities A11P MMI main PCB PHC1 (A4P) * optocoupler input circuit
A12P MMI display PCB Q1L thermal protector backup heater
: Not mounted in switch box
: Option A13P * LAN adapter Q3L, Q4L # safety thermostat
A14P * user interface PCB Q*DI # earth leakage circuit breaker
A15P * receiver PCB (wireless R1H (A2P) * humidity sensor
: PCB On/OFF thermostat)
: Wiring depending on model R1T (A1P) inlet water thermistor
B1L flow sensor R1T (A2P) * ambient sensor On/OFF thermostat
B1PW water pressure sensor R1T (A14P) * ambient sensor user interface
Note 1 : Connection point of the power supply for the BUH should be foreseen outside the unit. CN* (A4P) * connector R2T (A1P) outlet backup heater thermistor
DS1 (A5P) dipswitch R2T (A2P) * external sensor (floor or ambient)
Backup heater 6T1 (3~, 230V, 6kW) DS1 (A8P) * dipswitch R5T, R8T domestic hot water thermistor
power supply 6V (1N~, 230V, 6kW) POSITION IN SWITCH BOX E1H backup heater element (1 kW) R6T * external indoor or outdoor
6WN/9WN (3N~, 400V, 6/9kW) E2H backup heater element (2 kW) ambient thermistor
SWB1 E*P (A9P) indication LED R7T mixed leaving water thermistor
F1B # overcurrent fuse backup heater S1L flow switch
User installed options: LAN adapter F1T thermal fuse backup heater S1S # preferential kWh rate PS contact
TR1
Remote user interface F1U, F2U * fuse 5 A 250 V for digital I/O PCB S2S # electrical meter pulse input 1
X1M X2M (A4P)
X5M S3S # electrical meter pulse input 2
Ext. indoor thermistor
F1U, F2U fuse T 2 A 250 V for PCB S6S-S9S * digital power limitation inputs
Ext. outdoor thermistor A6P (A5P)
A8P SS1 (A4P) * selector switch
Digital I/O PCB FU1 (A1P) fuse T 5 A 250 V for PCB SW1~2 turn buttons
Demand PCB K7M FU2 (A10P) fuse T 1.6 A 250 V for PCB (A12P)
A1P
A5P K1M, K2M contactor backup heater SW3~5
Bottom plate heater A4P push button
K6M K5M safety contactor BUH (A12P)
Main LWT:
K6M relay 3 way valve bypass TR1 power supply transformer
On/OFF thermostat (wired)
K7M relay 3 way valve flow X6M # BUH power supply terminal strip
On/OFF thermostat (wireless) A10P
K*R relay on PCB X*, X*A, J* connector
Ext. thermistor K5M K1M K2M Q1L (A1P, A4P) X*H*, X*Y
Heat pump convector X*M terminal strip
Safety thermostat
SWB2
Add LWT:
On/OFF thermostat (wired)
On/OFF thermostat (wireless)
Ext. thermistor
Heat pump convector