0% found this document useful (0 votes)
18 views

AAS-Ordering-Guide

The Agilent AAS Ordering Guide provides comprehensive information for configuring and ordering Atomic Absorption Spectroscopy (AAS) systems, including various models, accessories, and application-specific configurations. It includes detailed sections on different applications such as environmental analysis, materials and mining, and pharmaceuticals, along with ordering instructions and software options. The guide is effective from March 24, 2023, and emphasizes contacting local product specialists for unusual configurations.

Uploaded by

Umar Bin Riaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
18 views

AAS-Ordering-Guide

The Agilent AAS Ordering Guide provides comprehensive information for configuring and ordering Atomic Absorption Spectroscopy (AAS) systems, including various models, accessories, and application-specific configurations. It includes detailed sections on different applications such as environmental analysis, materials and mining, and pharmaceuticals, along with ordering instructions and software options. The guide is effective from March 24, 2023, and emphasizes contacting local product specialists for unusual configurations.

Uploaded by

Umar Bin Riaz
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 63

Agilent AAS Ordering Guide March 2023

Agilent AAS
Ordering Guide and
Configuration Assistant

This Ordering Guide and Configuration


Assistant should enable AAS
configurations and quotes to be
generated, complete with all required
peripherals, options and accessories.

For unusual applications and hardware


combinations, please contact your local
Product Specialist before quoting.

NOTE:
This ordering guide comes into effect on
24th March 2023

Page 1 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Contents
Configuration Assistance for specific applications ................................................................. 4
Environmental.................................................................................................................... 4
Materials and Mining .......................................................................................................... 6
Semicon ............................................................................................................................ 6
Oils and Petrochemical ........................................................................................................ 7
Pharmaceutical................................................................................................................... 7
Flame AAS systems............................................................................................................. 8
Typical Flame AAS/Desktop PC Bundle Contents...................................................................... 9
Agilent 55B AA Spectrometer Bundle ..................................................................................... 9
Agilent 240FS AA Spectrometer ...........................................................................................12
Agilent 280FS AA Spectrometer ...........................................................................................14
240FS/GTA120/PSD120/UltrAA System.................................................................................16
Graphite Furnace AAS Instruments .....................................................................................18
Typical Graphite Furnace AAS/Desktop PC Bundle Contents .....................................................18
Agilent 240Z AA Spectrometer with integrated UltrAA lamp supply ...........................................18
Agilent 280Z AA Spectrometer .............................................................................................20
DUO Systems.....................................................................................................................22
Typical Duo AAS/Desktop PC Bundle Contents .......................................................................22
Consumables Kits...............................................................................................................25
Light sources for AA............................................................................................................26
Hollow Cathode Lamps .......................................................................................................26
Multi-element hollow cathode lamps ...................................................................................28
Continuum lamps for background correction .........................................................................28
High Intensity UltrAA lamps.................................................................................................28
High Intensity Multi-element UltrAA lamps............................................................................29
Burners (After Sales) ..........................................................................................................29
Accessories ........................................................................................................................30
SIPS Sample Introduction Pump System ................................................................................30
SPS 4 Sample Preparation System ........................................................................................31
GTA 120 ...........................................................................................................................33
VGA-77 ............................................................................................................................36
UltrAA lamp control module ................................................................................................39
ACT-80 Atom Concentrator Tube .........................................................................................39

Page 2 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Exhaust systems ................................................................................................................40


Compressor ......................................................................................................................41
Instrument Software ............................................................................................................42
SpectrAA Base Software......................................................................................................42
SpectrAA Pro software........................................................................................................43
SpectrAA Pro SW Upgrade...................................................................................................43
SpectrAA SW Base to Pro Upgrade .......................................................................................44
SpectrAA CFR software .......................................................................................................44
Ordering Instructions...........................................................................................................45
IQ/OQ.................................................................................................................................46
Appendix –Instrument and Accessory Contents ...................................................................58
Appendix – PC Requirements .............................................................................................61
Minimum computer configuration........................................................................................61
Recommended computer configuration ................................................................................61
PC for Agilent AAS Instruments ............................................................................................61

Page 3 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Configuration Assistance for specific applications


This section is a guide only. Any configuration can generally be used for any market segment.
Please consult with your local PS to get some more specific guidance.

Environmental, Food and Agriculture


For ppm to % level analysis for environmental, food, agricultural samples.
• Include VGA and ETC-60 for low level determination As, Hg, Se.
• Include ACT-80 for extra sensitivity in air/acetylene flame

Part # Description
G8434AA Agilent 280FS AA Spectrometer, with PC, monitor, printer and SpectrAA Pro SW
G8434AA #003 Add Nitrous Oxide/Acetylene Burner
G8451A Agilent Exhaust System
G8453A Air Compressor – Oil Free
G8439A SIPS 20 (For standard preparation, autodiluton AND addition of modifiers and
internal standards)
G8490A Agilent SPS 4 Autosampler
G8444A VGA-77
G8444A #100 ETC-60 (For flame free unattended hydride analysis)
110656800 ACT-80 Atom Concentrator Tube
Lamps Application Specific HC Lamps
R3999B 100 Training Credits. Need 4 of these for 1 Day Flame Operation and
Maintenance
H2149A #001 Onsite Application Consulting – 1 Day
SYS-AA-280-E #6H9 AA 240/280 Hardware AIQ (IQ/OQ) Advanced
SYS-SW-CS #6H9 AA 240/280 Software AIQ (IQ/OQ) Advanced
SYS-AA-280-E #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service
Contract

Page 4 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

For ppb to sub-ppb trace level analysis for environmental, food and agricultural samples

Part # Description
G8436AA Agilent 240Z AA Spectrometer with integrated UltrAA lamp supply, with PC,
monitor, printer and SpectrAA Base SW
G8436AA #202 Fume Extraction system – GTA
G8436AA #204 130 sample carousel kit – PSD
G8436AA #900 Upgrade to SpectrAA Pro (For QC f unctionality)
G8496A Chiller
G8451A Agilent Exhaust System
Lamps Application Specific HC Lamps and High Intensity UltrAA lamps
R3999B 100 Training Credits. Need 18 of these for 3 Day Advanced Furnace Operation
H2149A #001 Onsite Application Consulting – 1 Day
SYS-AA-280Z #6H9 AA 240/280 Hardware AIQ (IQ/OQ) Advanced
SYS-SW-CS #6H9 AA 240/280 Software AIQ (IQ/OQ) Advanced
SYS-AA-280Z #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service
Contract

For flexibility to analyze sub-ppb to % concentrations in environmental, food and agricultural samples

Part # Description
G8442AA AA Duo 280FS/280Z/UltrAA System, with PC, monitor, printer and SpectrAA Pro
SW
G8442AA #003 Add Nitrous Oxide/Acetylene Burner
G8442AA #202 Fume Extraction system – GTA
G8442AA #204 130 sample carousel kit – PSD
G8439A SIPS 20
G8451A Agilent Exhaust System
G8453A Air Compressor – Oil Free
G8496A Chiller
Lamps Application Specific HC Lamps and High Intensity UltrAA lamps
R3999B 100 Training Credits. Need 18 of these for 3 Day Advanced Furnace Operation
H2149A #002 Onsite Application Consulting – 2 Day
SYS-AA-DUO #6H9 AA 240/280 Hardware AIQ (IQ/OQ) Advanced
SYS-SW-CS #6H9 AA 240/280 Software AIQ (IQ/OQ) Advanced
SYS-AA-DUO #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service Contract

Page 5 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Materials and Mining


Analysis of ores and materials at ppm to % levels

Part # Description
G8432AA Agilent 240FS AA Spectrometer, with PC, monitor, printer and SpectrAA Pro SW
G8451A Agilent Exhaust System
G8453A Air Compressor – Oil Free
G8438A SIPS 10
110656800 ACT-80 Atom Concentrator Tube
G8490A Agilent SPS 4 Autosampler
Lamps Application Specific HC Lamps
R3999B 100 Training Credits. Need 4 of these for 1 Day Flame Operation and
Maintenance
H2149A #001 Onsite Application Consulting
SYS-AA-280-E #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service
Contract

Semicon
The 280Z provides the highest sensitivity, lowest detection limits and best resolution for semicon
applications

Part # Description
G8437AA Agilent 280Z AA Spectrometer with integrated UltrAA lamp supply, with PC,
monitor, printer and SpectrAA Pro SW
G8437AA #202 Fume Extraction system – GTA
G8437AA #204 130 sample carousel kit – PSD
G8496A Chiller
G8451A Agilent Exhaust System
Lamps Application Specific HC Lamps and High Intensity UltrAA lamps
R3999B 100 Training Credits. Need 18 of these for 3 Day Advanced Furnace Operation
H2149A #001 Onsite Application Consulting – 1 Day
SYS-AA-280Z #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service
Contract

Page 6 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Oils and Petrochemical


For the analysis of oils by flame AAS using the organics sample introduction

Part # Description
G8432AA Agilent 240FS AA Spectrometer, with PC, monitor, printer and SpectrAA Pro SW
G8432AA #001 Change to Organics Mark 7 spray chamber
G8451A Agilent Exhaust System
G8453A Air Compressor – Oil Free
Lamps Application Specific HC Lamps
G8438A SIPS 10
G8490A Agilent SPS 4 Autosampler
R3999B 100 Training Credits. Need 4 of these for a 1 Day Operation and Maintenance
H2149A #001 Onsite Application Consulting
SYS-AA-280-E #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service
Contract

Pharmaceutical

Part # Description
G8436AA Agilent 240Z AA Spectrometer with integrated UltrAA lamp supply, with PC,
monitor, printer and SpectrAA Base SW
G8436AA #202 Fume Extraction system – GTA
G8434AA #204 130 sample carousel kit – PSD
G8436AA #900 Upgrade to SpectrAA Pro (For QC f unctionality)
G8496A Chiller
G8451A Agilent Exhaust System
Lamps Application Specific HC Lamps and High Intensity UltrAA lamps
R3999B 100 Training Credits. Need 18 of these for 3 Day Advanced Furnace Operation
H2149A #001 Onsite Application Consulting – 1 Day
SYS-AA-280Z #6H9 AA 240/280 Hardware AIQ (IQ/OQ) Advanced
SYS-SW-CS-E #6H9 AA 240/280 Software AIQ (IQ/OQ) Advanced 21 CFR 11
SYS-AA-280Z #8R1 In the first year, takes standard warranty to CrossLab Silver Level Service
Contract

Back to Contents

Page 7 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Dedicated Mercury Analysis

Part # Description
G8430AA 55B AA Spectrometer
G8451A Agilent Exhaust System
Lamps Mercury (Hg) coded single element hollow cathode lamp (5610103400) or
Mercury (Hg) uncoded single element hollow cathode lamp, for all AAS
instruments with octal base connector (5610125300)
G8444A VGA-77 Vapor Generation Accessory
9910040700 Flow-through mercury cell
IAA-280 Mercury (Hg), in dilute HNO3 – 1,000 µg/mL
R3999B 100 Training Credits. Need 4 of these for 1 Day Flame Operation and
Maintenance
H2149A #001 Onsite Application Consulting – 1 Day
SYS-AA-55 #6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is
both IQ&OQ on the hardware at installation and is cheaper than separately
including IQ and OQ.
SYS-SW-CS #6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)

Page 8 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Flame AAS systems

Typical Flame AAS/Desktop PC Bundle Contents


A standard Flame AAS/Desktop PC bundle will contain one or more of the following items:

1) Flame AAS instrument. Includes PC, software, printer, burner, spray chamber, GPIB-USB
converter and IEEE cable. Choose from:
a. 55B AA PC bundle
b. 240FS AA PC bundle
c. 280FS AA PC bundle
d. 240FS/GTA120/PSD120/UltrAA System
2) Accessories as required:
a. SIPS
b. SPS 4
c. GTA 120
d. VGA-77
e. UltrAA lamp control modules
3) Exhaust systems and Air Compressor, if required

Consumables Kits and Lamps as required.


See the Atomic Spectroscopy Supplies Catalogue for a full list of Hollow Cathode Lamps, UltrAA lamps,
spares and consumables.

Agilent 55B AA Spectrometer Bundle

Part
Description
Number

Page 9 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

G8430AA Agilent 55B AA Spectrometer Bundle


Note: Not Available in Gr. China

Description
The 55B AA Spectrometer is a rugged and reliable
double beam AA system with advanced capabilities.
Featuring an integrated LCD screen and dedicated
keyboard enabling simple, stand-alone operation.
The 55B also f eatures automatic lamp selection,
automatic gas control (manual adjustment of
acetylene) and D 2 background correction. This
conf iguration allows an SPS 4 autosampler and SIPS to be used with the 55B AA.

Includes spectrometer, Desktop PC, monitor, color printer, SpectrAA Base software,
standard Mark 7 spray chamber, Air/Acetylene burner, connecting cables and GPIB-USB
converter (7910051600).
Select other options as required.
Ensure to order Electronic Control Module when adding SIPS (see SIPS section, option
#100)

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• Includes PC, monitor and printer
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• See Appendix for full list of parts included with the 55B AA

Options for the Agilent 55B AA Spectrometer Bundle

#001 Change to Organics Mark 7 spray chamber.

Description
Replaces the standard Mark 7 spray chamber with a Mark 7 spray chamber fitted with
organics resistant O-rings.

Order Instruction
• Select this option if only organic samples will be analysed.
• If the customer is analysing both aqueous and organic samples, order the
Organics O-ring kit (9910093500) instead.

#002 Change to Nitrous Oxide/Acetylene burner

Description
Replaces the Air/Acetylene burner with a Nitrous Oxide/Acetylene burner. Cannot be
ordered with option #003.

#003 Add Burner - Nitrous Oxide/Acetylene.

Description
Adds a Nitrous Oxide/Acetylene burner to the Air/Acetylene burner supplied with the
instrument. Cannot be ordered with option #002.

Page 10 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#695 Delete PC, monitor and printer


(Please select this option for stand-alone operation)

Description
Deletes the PC, monitor, printer and all associated PC cables.

Note:
• This option does not remove the GPIB-USB converter (7910051600) or the
SpectrAA Base software
• Customer must provide their own PC and must meet the PC requirements if they
would like to use the supplied SpectrAA software.

#790 Delete Monitor

Description
Deletes the Monitor only.
Select this option if the customer wants to provide their own monitor.

#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.

#900 Upgrade to SpectrAA Pro

Description
Upgrade to SpectrAA Pro. SpectrAA Pro software supports Duo operation, Fast
Sequential operation (with applicable hardware), Internal Standard corrections, and
advanced QC operation.

110454200 Remote read footswitch

Description
Allows remote triggering of the Read command using a foot operated pedal

Page 11 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Agilent 240FS AA Spectrometer


Part
Description
Number
G8432AA Agilent 240FS AA Spectrometer

Description
The 240FS AA Spectrometer supports Fast
Sequential operation, enabling rapid multiple
elemental analysis in a single sample
measurement, offering time, gas and error
savings
Features automatic lamp selection, programmable
gas control and D 2 background correction.

Includes spectrometer, Desktop PC, monitor,


color printer, SpectrAA Pro software, standard
Mark 7 spray chamber, Air/Acetylene burner,
integrated SIPS power supply, connecting cables and GPIB-USB converter (7910051600).
Select other options as required.

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• See Appendix for full list of parts included with the 240FS AA
• To use UltrAA Lamps, the UltrAA lamp control module (G8445A) and UltrAA lamp
retrof it kit for Agilent 50/55/140/240 instruments (9910094200) are required.

Options for the Agilent 240FS AA Spectrometer

#001 Change to Organics Mark 7 spray chamber.

Description
Replaces the standard Mark 7 spray chamber with a Mark 7 spray chamber fitted with
organics resistant O-rings.

Order Instruction
• Select this option if only organic samples will be analysed.
• If the customer is analysing both aqueous and organic samples, order the
Organics O-ring kit (9910093500) instead.

#002 Change to Nitrous Oxide/Acetylene burner

Description
Replaces the Air/Acetylene burner with a Nitrous Oxide/Acetylene burner. Cannot be
ordered with option #003.

Page 12 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#003 Add Burner - Nitrous Oxide/Acetylene.

Description
Adds a Nitrous Oxide/Acetylene burner to the Air/Acetylene burner supplied with the
instrument. Cannot be ordered with option #002.

#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide their
own PC and must meet the PC requirements.

#790 Delete Monitor

Description
Deletes the Monitor only. Select this option if the customer wants to provide their own
monitor.
#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.

Page 13 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Agilent 280FS AA Spectrometer

Part Number Description

G8434AA Agilent 280FS AA Spectrometer

Description
The 280FS AA f lame instrument combines
our world-leading Fast Sequential design
with eight lamp capacity and integrated
SIPS power supply. Fitted with the high
specification optical system for best
resolution and performance.

Features automatic lamp selection and


programmable gas control, integrated SIPS
power supply, and UltrAA lamp looms.

Includes spectrometer, Desktop PC,


monitor, color printer, SpectrAA Pro
sof tware, standard Mark 7 spray chamber, Air/Acetylene burner, connecting cables
and GPIB-USB converter (7910051600).

Select other options as required.

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• See Appendix for full list of parts included with the 280FS AA
• UltrAA lamp power supplies are not included, but can be ordered with option
#200

Options for the Agilent 280FS AA Spectrometer

#001 Change to Organics Mark 7 spray chamber.

Description
Replaces the standard Mark 7 spray chamber with a Mark 7 spray chamber fitted with
organics resistant O-rings.

Order Instruction
• Select this option if only organic samples will be analysed.
• If the customer is analysing both aqueous and organic samples, order the
Organics O-ring kit (9910093500) instead.

#002 Change to Nitrous Oxide/Acetylene burner

Description
Replaces the Air/Acetylene burner with a Nitrous Oxide/Acetylene burner. Cannot be
ordered with option #003.

Page 14 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#003 Add Burner - Nitrous Oxide/Acetylene.

Description
Adds a Nitrous Oxide/Acetylene burner to the Air/Acetylene burner supplied with the
instrument. Cannot be ordered with option #002.

#200 Add UltrAA lamp control module.

Description
The UltrAA lamp uses a modified lamp current to increase the emission intensity.
UltrAA lamp control modules can power up to 2 UltrAA lamps

Order Instruction
• Up to 2 UltrAA lamp control modules can be ordered.
#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide
their own PC and must meet the PC requirements.

#790 Delete Monitor

Description
Deletes the Monitor only. Select this option if the customer wants to provide their own
monitor.
#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.

Page 15 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

240FS/GTA120/PSD120/UltrAA System

Part Number Description

G8447AA 240FS/GTA120/PSD120/UltrAA System

Description
240FS/GTA120/PSD120/UltrAA System.
Perf orm Flame AA analysis with 240FS AA
measures all elements in each sample,
bef ore progressing to subsequent samples.
Features automatic lamp selection and
programmable gas control, integrated SIPS
power supply and UltrAA lamp looms.
Bundled with a GTA 120, PSD 120 for
graphite furnace determinations (includes
50 sample carousel).

Includes spectrometer, Desktop PC, monitor, color printer, SpectrAA Pro software,
standard Mark 7 spray chamber, Air/Acetylene burner, connecting cables and GPIB-
USB converter (7910051600). Also includes GTA 120 and PSD 120 accessories,
GTA camera and UltrAA lamp control module. Select other options as required.

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• Order a water chiller, if required
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• See Appendix for full list of parts included with the
240FS/GTA120/PSD120/UltrAA System

Options for the 240FS/GTA120/PSD120/UltrAA System

#001 Change to Organics Mark 7 spray chamber.

Description
Replaces the standard Mark 7 spray chamber with a Mark 7 spray chamber fitted
with organics resistant O-rings.

Order Instruction
• Select this option if only organic samples will be analysed.
• If the customer is analysing both aqueous and organic samples, order the
Organics O-ring kit (9910093500) instead.

#002 Change to Nitrous Oxide/Acetylene burner

Description
Replaces the Air/Acetylene burner with a Nitrous Oxide/Acetylene burner. Cannot be
ordered with option #003.

Page 16 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#003 Add Burner - Nitrous Oxide/Acetylene.

Description
Adds a Nitrous Oxide/Acetylene burner to the Air/Acetylene burner supplied with the
instrument. Cannot be ordered with option #002.

#200 Add UltrAA lamp control module.

Description
The UltrAA lamp uses a modified lamp current to increase the emission intensity.
UltrAA lamp control modules can power up to 2 UltrAA lamps

Order Instruction
• 1 additional UltrAA lamp control module can be ordered
#202 Fume Extraction system – GTA

Description
Fume Extraction system - GTA (includes Light and Mirror Assembly)

#204 130 sample carousel kit – PSD

Description
The 130 sample carousel kit for the PSD
120.
#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide
their own PC and must meet the PC requirements.

#790 Delete Monitor

Description
Deletes the Monitor only. Select this option if the customer wants to provide their
own monitor.
#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.

Page 17 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Graphite Furnace AAS Instruments

Typical Graphite Furnace AAS/Desktop PC Bundle Contents


A standard GFAAS/Desktop PC bundle will contain one or more of the following items:

1) Graphite Furnace AAS instrument. Includes PC, software, printer, GTA-120, PSD 120
autosampler, GPIB-USB converter and IEEE cable. Choose from:
a. 240Z PC bundle (with integrated UltrAA control module)
b. 280Z PC bundle
2) Accessories as required:
a. VGA-77
b. UltrAA lamp control modules
3) Exhaust systems and water chiller, if required
4) Consumables kits and Lamps as required. See the Atomic Spectroscopy Supplies Catalogue for
a f ull list of Hollow Cathode Lamps, UltrAA lamps, spares and consumables.

Agilent 240Z AA Spectrometer with integrated UltrAA lamp supply


Part
Description
Number
G8436AA Agilent 240Z AA Spectrometer with integrated UltrAA lamp supply

Description
240Z AA is a PC-controlled Zeeman spectrometer
dedicated to graphite furnace atomic absorption
determinations using the GTA 120 and PSD 120.

Includes spectrometer with integrated UltrAA lamp


power supply, Desktop PC, monitor, color printer,
SpectrAA Base software, PSD 120 (includes 50 sample
carousel), GTA camera, connecting cables and GPIB-
USB converter (7910051600). Select other options as required.

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• Order a water chiller, if required
• See Appendix for full list of parts included with the 240Z AA with integrated UltrAA
lamp power supply

Options for the Agilent 240Z AA Spectrometer with integrated UltrAA lamp supply

#200 Add UltrAA lamp control module.

Description
The UltrAA lamp uses a modified lamp current to increase the emission intensity. UltrAA
lamp control modules can power up to 2 UltrAA lamps

Order Instruction
• 1 additional UltrAA lamp control module can be ordered

Page 18 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#202 Fume Extraction system – GTA

Description
Fume Extraction system - GTA (includes Light and Mirror
Assembly)

#204 130 sample carousel kit – PSD

Description
The 130 sample carousel kit for the PSD 120.

#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide their
own PC and must meet the PC requirements.

#790 Delete Monitor

Description
Deletes the Monitor only. Select this option if the customer wants to provide their own
monitor.
#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.
#900 Upgrade to SpectrAA Pro

Description
Upgrade to SpectrAA Pro. SpectrAA Pro software supports Duo operation, Fast Sequential
operation (with applicable hardware), Internal Standard corrections, and advanced QC
operation.

Page 19 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Agilent 280Z AA Spectrometer


Part
Description
Number
G8437AA Agilent 280Z AA Spectrometer

Description
280Z AA is an 8 lamp PC-controlled Zeeman
spectrometer dedicated to graphite furnace atomic
absorption determinations using the GTA 120 and PSD
120 (includes 50 sample carousel).

Includes spectrometer with integrated UltrAA lamp


power supply, Desktop PC, monitor, color printer,
SpectrAA Base and Pro software, PSD 120 (includes 50 sample carousel), GTA camera,
connecting cables and GPIB-USB converter (7910051600).

Select other options as required.


Order Instruction
• I&I is included
• Introduction can be removed using #04N
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• Order a water chiller, if required
• See Appendix for full list of parts included with the 280Z AA

Options for the Agilent 280Z AA Spectrometer

#200 Add UltrAA lamp control module.

Description
The UltrAA lamp uses a modified lamp current to increase the emission intensity. UltrAA
lamp control modules can power up to 2 UltrAA lamps

Order Instruction
• 1 additional UltrAA lamp control module can be ordered
#202 Fume Extraction system – GTA

Description
Fume Extraction system - GTA
(includes Light and Mirror Assembly)

#204 130 sample carousel kit – PSD

Description
The 130 sample carousel kit for the PSD 120.

Page 20 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide their
own PC and must meet the PC requirements.
#790 Delete Monitor

Description
Deletes the Monitor only. Select this option if the customer wants to provide their own
monitor.
#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.

Page 21 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

DUO Systems

Typical Duo AAS/Desktop PC Bundle Contents


A standard Duo system bundle will contain one or more of the following items:

1) Duo systems include 2 spectrometers, PC, SpectrAA Pro software, printer, GPIB-USB converter
and IEEE cable. Choose from:
a. AA Duo 240FS/240Z/UltrAA System
b. AA Duo 280FS/280Z/UltrAA System
2) Accessories as required:
a. SIPS
b. SPS 4
c. GTA 120
d. VGA-77
e. UltrAA lamp control modules
3) Exhaust systems, air compressors, and water chiller, if required
4) Consumables Kits and Lamps as required. See the Atomic Spectroscopy Supplies Catalogue for
a f ull list of Hollow Cathode Lamps, UltrAA lamps, spares and consumables.

Part Number Description

G8449AA AA Duo 240FS/240Z/UltrAA System

Description
Agilent 240FS and 240Z AA Duo systems are configured for simultaneous operation
of an Agilent 240FS AA flame spectrometer and an Agilent 240Z AA dedicated
f urnace spectrometer with Zeeman correction. The 240FS features automatic lamp
selection and programmable gas control.

Includes 240FS and 240Z spectrometers, Desktop PC, monitor, color printer,
SpectrAA Pro software, standard Mark 7 spray chamber, Air/Acetylene burner,
integrated SIPS power supply, connecting cables and GPIB-USB converter
(7910051600). 240Z includes GTA 120, PSD 120 (includes 50 sample carousel),
and integral UltrAA lamp PS. 240FS does not include UltrAA looms. Select other
options as required.
Order Instruction
• I&I is included
• Introduction can be removed using #04N
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• Order a water chiller, if required
• See Appendix for full list of parts included with the AA Duo
240FS/240Z/UltrAA System
G8442AA AA Duo 280FS/280Z/UltrAA System

Description
Agilent 280FS/280Z AA Duo is a system configured for simultaneous operation of an
Agilent 280FS AA flame spectrometer and an Agilent 280Z AA dedicated furnace
spectrometer with Zeeman correction. The 280FS features auto lamp selection and
programmable gas box.

Page 22 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Includes 280FS and 280Z spectrometers, Desktop PC, monitor, color printer,
SpectrAA Pro software, standard Mark 7 spray chamber, Air/Acetylene burner,
integrated SIPS power supply, connecting cables and GPIB-USB converter
(7910051600). 280Z includes GTA 120, PSD 120 (includes 50 sample carousel),
and integral UltrAA lamp PS. Select other options as required.

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• 1 Year SW Upgrade/Phone Assist is not included, but can be added
• Order a water chiller, if required
• See Appendix for full list of parts included with the AA Duo
280FS/280Z/UltrAA System

Options for the AA Duo Systems

#001 Change to Organics Mark 7 spray chamber.

Description
Replaces the standard Mark 7 spray chamber with a Mark 7 spray chamber fitted
with organics resistant O-rings.

Order Instruction
• Select this option if only organic samples will be analysed.
• If the customer is analysing both aqueous and organic samples, order the
Organics O-ring kit (9910093500) instead.
#002 Change to Nitrous Oxide/Acetylene burner

Description
Replaces the Air/Acetylene burner with a Nitrous Oxide/Acetylene burner. Cannot be
ordered with option #003.

#003 Add Burner - Nitrous Oxide/Acetylene.

Description
Adds a Nitrous Oxide/Acetylene burner to the Air/Acetylene burner supplied with the
instrument. Cannot be ordered with option #002.

#200 Add UltrAA lamp control module.

Description
The UltrAA lamp uses a modified lamp current to increase the emission intensity.
UltrAA lamp control modules can power up to 2 UltrAA lamps

Order Instruction
• 1 additional UltrAA lamp control module can be ordered for the AA Duo
240FS/240Z/UltrAA system
• 3 additional UltrAA lamp control module can be ordered for the AA Duo
280FS/280Z/UltrAA system (2 f or the 280FS and 1 for the 280Z)
#202 Fume Extraction system – GTA

Description
Fume Extraction system - GTA (includes Light and Mirror Assembly)

Page 23 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#204 130 sample carousel kit – PSD

Description
The 130 sample carousel kit for the PSD
120.
#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide
their own PC and must meet the PC requirements.

#790 Delete Monitor

Description
Deletes the Monitor only. Select this option if the customer wants to provide their
own monitor.
#890 Delete Printer

Description
Deletes the Printer only. Select this option if the customer does not want the printer.

Page 24 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Consumables Kits

Part Number Description Contents

190034100 Mark 7 f lame • Nebulizer venturi, capillary kit, nebulizer block (with
atomization integral nebulizer),
system operating • Glass impact beads
supplies • Capillary tubing
kit • Ring kit
• Mixing paddles
• Burner cleaning strips
190067900 Graphite Furnace • 2 sets graphite electrodes for GTA 120
operating supplies • Graphite shroud for GTA 120
kits f or GTA 120 • 5 packs Omega tubes (each 10/pk)
Deuterium GFAAS • 100 uL syringe for PSD
• Capillary assemblies (5/Pk)
• Plastic vessels (5/Pk)
• 2 packs 2 mL furnace vials (each 1000/Pk)
190068000 Graphite Furnace • 2 sets graphite electrodes for Zeeman
operating supplies • Graphite shroud for GTA 120 Zeeman
kit f or GTA 120 • 5 packs Omega tubes (each 10/pk)
Zeeman GFAAS • 100 uL syringe for PSD
• Capillary assemblies (5/Pk)
• Plastic vessels (5/Pk)
• 2 packs 2 mL furnace vials (each 1000/Pk)
190025200 VGA 77 vapor • 2 sets tubing and connector kits
generation operating • 2 packs sample pump tubes (each 12/Pk)
supplies • 2 packs reagent pump tubes (each 12/Pk)
kit • 1 set replacement pump beds
• 1 replacement gas-liquid separator
• 1 Hg Flow Through Cell (1/Pk)
• 2 sets hydride absorption cell (each 2/PK0
• 1 spare hydride module
190025400 SIPS f lame dilution • 2 x 500 mL constant pressure vessel
system operating • 1 x 1L diluent bottle
supplies • 1 Tee piece assembly
kit • 1 Pack SIPS pump tubing (6/Pk)
• 1 Pack Pump Bands’
• 1 SIPS tubiing kit

Page 25 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Light sources for AA

Hollow Cathode Lamps


Agilent hollow cathode lamps provide optimum signal-to-noise performance permitting
determinations at even lower levels with the most demanding applications. Agilent lamps
are manufactured in an ISO 9001 certified environment, so they are optimized to deliver
the best performance from your AA. Agilent lamps provide high spectral purity because of
the purified materials, the extended processing cycle and the unique lamp conditioning
procedure. This ensures minimal lamp warm-up time and good stability during operation.

Economical operation is assured by the long lamp life, which exceeds 5000 mA hours of
operation over and above Agilent’s preconditioning and testing service.

Agilent manufactured hollow cathode lamps are compatible with all atomic absorption
spectrometers, except PerkinElmer AA systems (a separate range of lamps is available for
PerkinElmer AA systems). Coded versions are available for automatic lamp recognition or lower
priced uncoded versions are available.

Element Part Number Part Number


Coded Uncoded
Ag (Silver) 56 101052 00 56 101272 00
Al (Aluminium) 56 101001 00 56 101220 00
As (Arsenic) 56 101003 00 56 101222 00
Au (Gold) 56 101021 00 56 101240 00
Be (Beryllium) 56 101005 00 56 101224 00
B (Boron) 56 101007 00 56 101226 00
Ba (Barium) 56 101004 00 56 101223 00
Bi (Bismuth) 56 101006 00 56 101225 00
Ca (Calcium) 56 101010 00 56 101229 00
Cd (Cadmium) 56 101008 00 56 101227 00
Co (Cobalt) 56 101013 00 56 101232 00
Cr (Chromium) 56 101012 00 56 101231 00
Cs (Cesium) N/A 56 101228 00
Cu (Copper) 56 101014 00 56 101233 00
Eu (Europium) N/A 56 101236 00
Fe (Iron) 56 101027 00 56 101246 00
Ga (Gallium) N/A 56 101238 00
Gd (Gadolinium) N/A 56 101237 00
Ge (Germanium) N/A 56 101239 00
Hf (Haf nium) 56 101022 00 56 101241 00
Hg (Mercury) 56 101034 00 56 101253 00
In (Indium) N/A 56 101244 00
Element Part Number Part Number
Coded Uncoded
Ir (Iridium) 56 101026 00 56 101245 00

Page 26 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

K (Potassium) 56 101042 00 56 101262 00


La (Lanthanum) N/A 56 101247 00
Li (Lithium) 56 101030 00 56 101249 00
Mg (Magnesium) 56 101032 00 56 101251 00
Mn (Manganese) 56 101033 00 56 101252 00
Mo (Molybdenum) 56 101035 00 56 101254 00
Na (Sodium) 56 101053 00 56 101273 00
Nb (Niobium) 56 101038 00 56 101257 00
Nd (Neodymium) 56 101036 00 56 101255 00
Ni (Nickel) 56 101037 00 56 101256 00
P (Phosphorus) 56 101077 00 56 101260 00
Pb (Lead) 56 101029 00 56 101248 00
Pd (Palladium) 56 101040 00 56 101259 00
Pt (Platinum) 56 101041 00 56 101261 00
Rb (Rubidium) N/A 56 101266 00
Re (Rhenium) 56 101044 00 56 101264 00
Rh (Rhodium) 56 101045 00 56 101265 00
Ru (Ruthenium) N/A 56 101267 00
Sb (Antimony) 56 101002 00 56 101221 00
Sc (Scandium) N/A 56 101269 00
Se (Selenium) 56 101050 00 56 101270 00
Si (Silicon) 56 101051 00 56 101271 00
Sm (Samarium) N/A 56 101268 00
Sn (Tin) 56 101061 00 56 101281 00
Sr (Strontium) 56 101054 00 56 101274 00
Ta (Tantalum) 56 101055 00 56 101275 00
Te (Tellurium) 56 101056 00 56 101276 00
Ti (Titanium) 56 101062 00 56 101282 00
Tl (Thallium) 56 101058 00 56 101278 00
V (Vanadium) 56 101065 00 56 101285 00
W (Tungsten) N/A 56 101283 00
Y (Yttrium) N/A 56 101287 00
Zn (Zinc) 56 101068 00 56 101288 00
Zr (Zirconium) 56 101069 00 56 101289 00

Page 27 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Multi-element hollow cathode lamps


Elements Part Number Part Number
Coded Uncoded
Ag/Cd/Pb/Zn 56 101087 00 N/A
Ag/Cr/Cu/Fe/Ni 56 101095 00 N/A
Al/Ca/Mg 56 101088 00 N/A
Ca/Mg 56 101071 00 56 101291 00
Co/Cr/Cu/Fe/Mn/Ni 56 101076 00 56 101292 00
Cu/Zn 56 101192 00 56 101293 00
Cu/Fe/Mn/Zn 56 101096 00 N/A
Cu/Fe/Si/Zn 56 101097 00 N/A
Na/K 56 101070 00 56 101290 00

Deuterium lamps for background correction


These lamps are used in background correction systems. All Agilent AA instruments use the
deuterium lamp.
Deuterium G8431-80000

High Intensity UltrAA lamps


Agilent UltrAA lamps are high intensity boosted discharge hollow cathode lamps. They
use the standard lamp current, but apply an additional boost discharge within the lamp to
increase the emission intensity. The boost current is supplied from a secondary control
module (either integrated into the instrument or supplied from an external module).

Element Coded Part Number


As (Arsenic) Y 56 101081 00
Au (Gold) Y 56 101090 00
Bi (Bismuth) Y 56 101342 00
B (Boron) Y 56 101357 00
Co (Cobalt) Y 56 101341 00
Cu (Copper) Y 56 101091 00
Fe (Iron) Y 56 101086 00
Ge (Germanium) Y 56 101343 00
Mn (Manganese) Y 56 101337 00
Ni (Nickel) Y 56 101085 00
Pb (Lead) Y 56 101082 00
Pd (Palladium) Y 56 101358 00
Pt (Platinum) Y 56 101359 00
Sb (Antimony) Y 56 101080 00
Se (Selenium) Y 56 101083 00
Si (Silicon) Y 56 101334 00
Sn (Tin) Y 56 101339 00
Te (Tellurium) Y 56 101340 00
Tl (Thallium) Y 56 101084 00

Page 28 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

High Intensity Multi-element UltrAA lamps

Element Coded Part Number


Ag/Cd/Pb/Zn Y 56 101089 00
Ag/Cr/Cu/Fe/Ni Y 56 101349 00
Al/Ca/Mg Y 56 101336 00
As/Cu/Fe N 56 101353 00
Co/Cr/Cu/Fe/Mn/Ni Y 56 101345 00
Co/Mo/Pb/Zn Y 56 101352 00
Cu/Zn Y 56 101346 00
Cu/Fe/Mn/Zn Y 56 101350 00
Cu/Fe/Si/Zn Y 56 101351 00
Ni/Se N 56 101354 00

Burners (After Sales)

Part Number Description

210164000 Mark 7 air-acetylene burner

210164100 Mark 7 nitrous oxide-acetylene burner

Page 29 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Accessories

SIPS Sample Introduction Pump System


The Sample Introduction Pump System (SIPS) is an innovative sample introduction and dilution system
f or f lame AA that eliminates the task of multiple standard preparation
and provides fast, accurate online dilution of over-range samples.
SIPS is available in 2 versions:
• The single pump SIPS 10
• The dual pump SIPS 20

The SIPS 10/20 can be used on all PC-controlled Agilent AA


instruments in the current range. The 55 Series AA systems (operating
as stand-alone systems without PC) can be fitted with the SIPS 10
only.

For SIPS spare and consumables see the Atomic Spectroscopy


Supplies Catalogue

Part Number Description

G8438A SIPS 10

Description
The SIPS 10 is a sample introduction and dilution system that eliminates the task of
multiple standard preparation and provides dilution of over-range samples. This is the
single pump version

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• The external Electronic SIPS Control Module (#100) is no longer
available. Customers with a 55B AA or older models (eg. 240 AA, 220 AA)
will not be able to use the SIPS 10 unless they already have a previously
purchased external Electronic SIPS Control Module.
• See Appendix for full list of parts included with the SIPS 10

G8439A SIPS 20

Description
The SIPS 20 is a dual pump sample introduction and dilution system that eliminates
the task of multiple standard preparation and provides dilution of over-range samples.

Order Instruction
• I&I is included
• The external Electronic SIPS Control Module (#100) is no longer
available. Customers with a 55B AA or older models (eg. 240 AA, 220 AA)
will not be able to use the SIPS 20 unless they already have a previously
purchased external Electronic SIPS Control Module.
• See Appendix for full list of parts included with the SIPS 20

Page 30 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Options for the SIPS 10 and SIPS 20

190025400 SIPS flame dilution system operating supplies kit

Description
2 x 500 mL constant pressure vessel
1 x 1L diluent bottle
1 Tee piece assembly
1 Pack SIPS pump tubing (6/Pk)
1 Pack Pump Bands’
1 SIPS tubing kit

SPS 4 Sample Preparation System

The Agilent SPS 4 autosampler is compatible with current AA, MP-


AES and ICP-OES spectrometers. It is designed to meet the diverse
requirements of high-throughput analytical laboratories. It offers a
range of productivity-boosting features to speed up analysis times.
The Agilent SPS 4 also provides a launching pad for a number of
additional options that further improve the quality of analytical results
and reduce running costs.

For SPS 4 or SPS 3 spares and consumables see the Atomic Spectroscopy Supplies Catalogue

Part Number Description

G8490A SPS 4 Autosampler (AA/MP-AES/ICP-OES)

The SPS 4 autosampler is designed to meet the requirements of high-throughput


laboratories requiring a f ast high capacity reliable autosampler. It offers a range of
productivity-boosting features to speed up analysis times. Comes with USB
communications cable and accessory kit for AAS, MP-AES and ICP-OES.

Order Instruction
• Installation & Introduction (I&I) is included
• Introduction can be removed using #04N
• See Appendix for full list of parts included with the SPS 4

NOTE:
For SPS 4 to be used with AAS systems purchased before May 1 st 2015, you MUST INCLUDE
the latest version of SpectrAA Software. The SPS 4 requires SpectrAA 5.3 or greater.

Options for the SPS 4 Autosampler (available at POIS)


#001 Add Kit Autosampler Trolley
Autosampler Trolley (cart) for SPS 4 f eatures lockable wheels and lower shelf for
storage.
#002 Add Integrated Cover Kit

Page 31 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Transparent SPS 4 cover prevents contamination of samples and standards from


dust and drafts. The cover fully encloses the system. The design includes an upward
sliding door for access to the samples and racks.
Duct hose (id. 50mm, 5m) to fit extraction air port on side
cover panel.

The Duct Hose (used to be Opt #003) is included in #002


f or the order placed after Nov.1, 2017.

Note:
• The duct hose should be used when the cover is installed
on the SPS 4. The active extraction air prevents possible
corrosion of internal components from sample vapors.
• Requires customer provided extraction air system (> 0.35 m3/min or > 3 m/sec) and
f ittings.
#005 Add high uptake volume rinse kit
For use with AVS systems
#006 Add Rinse tube kit for low volatile organics
For use with low volatile organic rinse solutions
#007 Add pumped drain kit
For use when gravity fed drain is not possible.
Supplies for the SPS 4 Autosampler
6610011800 10 L Rinse Vessel
Ensure you never run out of rinse solution during long unattended runs with a large
10 L rinse vessel
5042-4769 4L Polyethylene drainage tank
Suitable for waste solution
G8410-40000 34 position standards rack (Can accommodate 2 different sized tubes – 17mm
OD (16.5ml) and 29 mm OD (50ml))
6610026400 90 Position sample rack for 13 mm OD tubes
6610025400 60 Position sample rack for 16 mm OD tubes
6610025500 40 Position sample rack for 20 mm OD tubes
6610026500 24 Position sample rack for 25 mm OD tubes
6610026600 21 Position sample rack for 30 mm OD tubes
3710051100 Polypropylene sample tubes, 16 mm OD 125/pk (For the 60 position sample
rack)
190065200 Polypropylene tubes 50ml 500/pk for use with 34 position standards rack.
29mm od x 115mm. Features conical base, wide neck and threaded top for
screw cap closure. Graduated scale from 5 to 50ml at 2.5ml intervals.
00000001600L Polypropylene 17mm O.D. standard tubes suitable for the 34 position
standards rack (16.5ml). 1000/pk
G8410-80102 0.8mm ID sample probe kit, green marker. Inert – lined with fluoroplastic.
Standard probe used with AA systems
G8410-80103 1.0mm ID sample probe kit, blue marker. Inert – lined with fluoroplastic
G8410-80104 1.2mm ID sample probe kit, black marker. Inert – lined with fluoroplastic. For
viscous solutions and high matrix samples
G8410-80200 Autosampler Trolley kit
G8410-60100 Integrated Covers kit for the SPS 4
5043-0065 Duct hose (50mm) for extraction of all enclosed SPS 4 units
G8410-60150 SPS 4 Dual Port Reservoir kit
G8410-68260 SPS 4 high uptake volume rinse kit (for use with AVS systems)
G8410-68261 SPS 4 rinse tube kit for low volatile organics
G8410-68262 SPS 4 pumped drain kit for use when gravity fed drain is not possible

Page 32 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

GTA 120

Agilent’s integrated GTA 120 Graphite Tube Atomizer provides superior furnace performance, no matter
how difficult the sample, making it ideal for applications as diverse as Chemical, Petrochemical, Food and
Agriculture.
The GTA 120 f eatures a Constant Temperature Zone (CTZ) design, separate external and internal gas
f lows and a 2 stage external gas flow for reduced inert gas consumption. The Constant Temperature
Zone (CTZ) design of the GTA 120 graphite furnace provides low detection limits, excellent sensitivities,
long tube lifetimes and reduced memory effects. The CTZ is achieved by carefully matching the design of
the GTA 120 power supply to low mass, end-heated graphite tubes. This provides rapid, even heating for
unmatched performance and reduced memory effects.
The GTA120 is compatible with the Agilent 280/240/140 Series AA instruments ONLY.

Part Number Description

G8443A GTA 120

Description
GTA 120 f eatures Constant Temperature Zone design, separate external and
internal gas f lows, and 2 stage external gas flow for reduced inert gas
consumption. Includes the PSD 120 autosampler.

Order Instruction
• I&I is included
• Introduction can be removed using #04N
• Order a water chiller, if required
• It is recommended that some spare graphite tubes are supplied with the GTA
120
• See Appendix for full list of parts included with the GTA 120
Options for GTA 120
#100 Remove PSD120 Autosampler
#202 Fume Extraction system – GTA

Description
Fume Extraction system - GTA (includes Light and Mirror Assembly)
#204 130 sample carousel kit – PSD

Description
The 130 sample carousel kit for the PSD 120.
Additional Parts for GTA 120
9910115700 Kit, GTA Viewing Retrofit AA140240280

Description
GTA camera retrofit kit for 240 and 280 series instruments. Requires installation at
customer site.

Page 33 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

210190000 Fume Extraction system – GTA

Description
This is the stand alone part number for the Fume Extraction system - GTA (includes
Light and Mirror Assembly). Use this part number to order the fume extraction system
outside of the GTA 120 bundle.
10083400 PSD120 Furnace Autosampler

Description
Complete PSD120 autosampler for GTA120.
Includes: Carousel and cover,1 Litre rinse reservoir, spare capillary assembly, Sample
vials (1000 x 2 mL vials), Plastic Beakers PSD120 (5 x 10 mL))

Note: Does not include I&I

Graphite Furnace Heat exchanger or Water chiller

The Graphite Tube Atomizer requires a supply of cooling water to remove heat from the furnace
workhead during operation:
• Required Flow Rate: 1.5 L/min. at 180 kPa (27 psi)
• Maximum Pressure: 200 kPa (30 psi)

Page 34 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

• Recommended Inlet Temperature: 18 to 25 °C (65 to 70 °F)


• Maximum Inlet Water Temperature: 40 °C (104 °F)
Mains water supply can be used, but is not recommended for overnight operation.
An alternative is to install a recirculating water heat exchanger or a water chiller, which eliminates the
need f or a supply of mains water, thus reducing the running costs. A recirculating water heat exchanger
or water chiller also has the advantage of not requiring a large stored volume of water, reducing the risk
of flooding if there should be a plumbing leak. A recirculating water heat exchanger or water chiller
suitable for use with all Agilent graphite furnace and Zeeman graphite furnace systems can be ordered.

Where the heat exchanger or water chiller is to be sourced locally, the specifications of the unit supplied
must meet the above requirements.

Water Recirculator

Part Number Description

G1879B Water Recirculator (Heat exchanger)

Description
Liquid-to-air cooler, 1/3 HP turbine pump. Coolant fluid
(5779-0037). Comes in 200-240 Vac, 50 Hz and
100-120 Vac, 50/60 Hz

Order Instructions
• I&I is not included but can be added using #44K
(installation) and #44L (introduction)
• Compatible with all Agilent GFAAS

NOTE:
• G1879B is suitable where the ambient temperature around the water
recirculator does not exceed 30°C. Otherwise, order a water chiller
(G8489A).
• If buying the heat exchanger standalone without a graphite furnace
instrument, you many need to include hose fittings as none are included
specific for GFAAS. They can be added with the part number 9910088600
Kit Plumbing Water Coolers.
• Coolant fluid not available with Water Recirculator in Japan.
.
5779-0037 Coolant fluid
Coolant fluid for use at operating temperatures above 15oC to help prevent algae
growth.

NOTE:
• Coolant fluid not available in Japan

Water Chiller

Page 35 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

G8496A has either a 2.9 KW (@ 60Hz) cooling capability or 2.65kW cooling capacity (@50Hz) at 20 oC. It
is an air-cooled, non-CFC refrigerated recirculating water chiller. The chiller is fitted with a turbine pump
f or reliable operation at higher flows and pressures, especially useful when remotely locating the chiller
away f rom the instrument to minimize noise or heat issues in the laboratory. Accurate and precise
temperature control to +0.1oC ensures consistent performance from your Agilent Graphite Furnace AAS.
Large LCD display present actual temperature and flow rates simultaneously.

Part Number Description

G8496A Water Chiller


1HP compressor, 1.1 gal (4.2liters) reservoir capacity,
Coolant fluid, removable air filter, power cord, 2 x ½
inch NPT water connectors and 3m USB type A-B
cable. Comes in 200-240V/60Hz (13.5A), 200-
240V/50Hz (12A) configurations.

NOTE:
Hose f ittings for GFAAS are supplied within the
instrument installation kits for G8436AA, G8437AA and
G8447AA.

Order Instruction
• Installation is included with the instrument bundle, no need to add I&I line
item at POIS
• If purchasing the chiller stand alone, Installation MUST be included
and can be added using #44K (installation)
• If ordering in Japan, please use G8496A#001 for 50Hz and G8496A#002
f or 60Hz
• Compatible with all Agilent GFAAS

NOTE:
• Coolant fluid not available with chiller in Japan.
• Take note of the higher power requirements for the 1 HP chiller.
Details can be found in the Site Preparation Guide.
• Sound level is 61.2 dB.
• If buying the chiller standalone without a graphite furnace instrument, you
may need to include hose fittings as none are included specific for GFAAS.
They can be added with the part number 9910088600 Kit Plumbing Water
Coolers.

Agilent Water Chiller spare solution


5779-0037 Coolant fluid

NOTE:
• Coolant fluid not available in Japan

Page 36 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

VGA-77
The VGA-77 is a continuous flow vapor generation system for the determination of Hg and the hydride-
f orming elements at µg/L levels. It can be used with the Agilent AAS and ICP-OES instrument.
The VGA-77 does not interact with the software or instrument. It can be operated with any model of
Agilent AA spectrometer.

If you are using a Zeeman instrument, you will need a Zeeman adaptor to use a VGA.

ETC 60 Electrothermal Temperature Controller

The ETC 60 Electrothermal Temperature Controller is an electrically heated quartz cell which replaces
f lame heating of the quartz cell, when used for hydride analysis. As there is no flame, the ETC 60 can be
used with the SPS autosampler and VGA 77 for safe, unattended determinations on your Agilent AA.

By combining the ETC 60 with the VGA 77, Agilent Zeeman AA instruments can also be used for
determinations of the hydride elements using the vapor generation technique.

The lower atomization temperatures used with the ETC 60 also increase sensitivity by up to 30% when
compared with flame atomization.

The ETC-60 can be used with any instrument that can use the VGA 77.
Inclusions:
• Power supply and temperature controller
• Workhead (clamshell style allowing replacement of the absorption cell)
• Operation manual
• Power and communications cables

Part Number Description

G8444A VGA-77 Vapor Generation Accessory

Description
The VGA-77 is a continuous flow vapor
generation system for the determination of Hg
and the hydride-forming elements at µg/L levels.

Order Instruction
• I&I is included
• Introduction can be removed using
#04N
• See Appendix for full list of parts included with the VGA-77
#001 ETC 60 Electrothermal Temperature Controller

Description
ETC 60 Electrothermal Temperature Controller is an electrically heated quartz cell
replacing flame heating of the quartz cell. ETC 60 can be used with the
SPS4 + VGA-77 unattended.

Page 37 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#003 Add Kit HG Flow-through bracket

Description
Add Kit HG Flow-through cell mounting bracket for 240G AA and 220G.
#004 Add Zeeman Adaptor for VGA-77

Description
Add Zeeman Adaptor for VGA-77. Allows you to couple the VGA-77 Vapor
Generation Accessory with the ETC-60 Electrothermal Temperature Controller

Supplies for the VGA 77 and ETC 60

190025200 VGA 77 vapor generation operating supplies


Kit

Description
2 sets tubing and connector kits
2 packs sample pump tubes (each 12/Pk)
2 packs reagent pump tubes (each 12/Pk)
1 set replacement pump beds
1 replacement gas-liquid separator
1 Hg Flow Through Cell (1/Pk)
2 sets hydride absorption cell (each 2/PK0
1 spare hydride module
9910040000 Quartz absorption cells spare (Pk/2) for ETC-60
7910041500 Replacement ETC-60 Workhead Mark 2. Excludes cables and cells
9910062100 Hydride Module for VGA
9910040700 Flow-through mercury cell
10061100 ETC 60 Electrothermal Temperature Controller

Description
ETC 60 Electrothermal Temperature Controller is an electrically heated quartz cell
replacing flame heating of the quartz cell. ETC 60 can be used with the SPS 4 +
VGA-77 unattended.
Includes:
Power supply and temperature controller
Workhead (clamshell style allowing replacement of the absorption cell)
Operation manual
Power and communications cables

Page 38 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

UltrAA lamp control module

UltrAA lamps are a range of high intensity boosted discharge hollow cathode lamps. The UltrAA lamp
uses the existing lamp current but applies a second discharge within the lamp to increase the emission
intensity. The boost current is supplied from an external control module. UltrAA lamps are compatible with
all Agilent AA instruments. Note that any UltrAA lamps required must be ordered separately.

For a complete list of UltrAA lamps see the Atomic Spectroscopy Supplies Catalogue.
Part Number Description
G8445A UltrAA lamp control module

Description
The UltrAA lamp uses a modified lamp current to increase the
emission intensity. UltrAA lamp control modules can power up
to 2 UltrAA lamps

Order Instruction
• I&I is included. Both Installation and Introduction can
removed using #04R, or only Introduction can be
removed using #04N.
Field Retrofit Kits
9910094200 UltrAA lamp retrofit kit for Agilent 50/55/140/240 instruments.

Description
This kit is required for customers wanting to use UltrAA lamps on the 240FS or
on other older 50/55/140/240 models

NOTE:

• Each kit can power 2 UltrAA Lamps.

Order Instruction
• Requires service installation

ACT-80 Atom Concentrator Tube

The ACT 80 Atom Concentrator Tube is a quartz tube which is positioned in the air/acetylene
flame to enhance the sensitivity of flame AA by 2-3 times when compared to that of normal
flame AA. An improvement in detection limit is also achieved.

Includes:
10 ACT-80 tubes
Mounting bracket for air/acetylene burner
Operation instructions.
Accessory Part Number
ACT 80 Atom Concentrator Tube for 110656800
Mark 7 air/acetylene burner
ACT 80 Atom Concentrator Tube for 10043500
Mark VI air/acetylene burner

Page 39 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

ACT 80 Atom Concentrator Tube for 10043400


Mark V air/acetylene burner
Packet of 10 spare ACT-80 tubes 9910054400

Exhaust systems

For details of the exhaust and instrument installation requirements, refer to the Pre-installation instruction
manual.
It is the customer’s responsibility to prepare the site for the instrument.

Part Number Description


G8451A Agilent AA Exhaust System
A kit available with the components required for exhaust
extraction for AAS, MP-AES and ICP-OES. Installation is
not included with this kit, and it cannot be added. Please
see order instructions below.

The kit includes:


• 1 x Exhaust Fan (240V, 50Hz or 115V, 60Hz)
• 3 x Flexible ducting 1 meter length, Aluminum
• 2 x Couplings
• 4 x Clamps
• 1 x Flue (f or AAS applications)

Order Instructions
• Installation is NOT included.
• Depending on local regulations, installation may require a contractor.
• Introduction is included

Extra Components for the Exhaust System


410000400 Extra flexible Aluminium ducting 150 mm diameter
1610000200 Spare 150 mm diameter coupling
810000300 Spare flexible ducting clamps

Options for the Exhaust System


G8010-68002 External cooling air supply duct
This inlet duct adapter can be used to connect a supply of clean, dry
air to the instrument from outside the laboratory. It can reduce
problems with corrosion or contamination in dusty or corrosive
laboratory environments. The duct can be ordered with the G8451A
exhaust kit which can be used as a blower system with an
appropriate sheet metal adapter.
G8451A#100 Delete f lue from the Agilent Exhaust System.

Page 40 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Compressor
For details of the compressor requirements, refer to the Pre-installation instruction manual.

Part Number Description

G8453A Air Compressor - Oil Free 38l/min @ 8bar


Description
Oil f ree Air Compressor
Power Rating 230V 50-60Hz

Order Instruction
• I&I is included
• I&I can be removed using #04R
• Compressor can be configured for different power
supply requirements
• Not compatible in countries with typical mains voltages between
100-130V
o Including USA, Japan, Mexico and some countries in LAR
o Please check the Voltage available at customer sites before placing
order
• Not for sale in Japan. In Japan a compressor must be sourced locally

Page 41 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Instrument Software
SpectrAA 5.6 Base and Pro software is compatible with Microsoft Windows 10 Professional or
Enterprise 64-bit. Tested on AA55, 240, 240/280 FS, 240/280 Zeeman.
Microsoft Windows 7 operating systems is no longer supported.

SpectrAA Base Software


Note: this software is included as standard with all PC controlled AA instrument orders.
Part Description
Number
G9270AA SpectrAA Base Software v5.6

Description
SpectrAA Base Software. Includes PC.
Note: this software is included as standard with all PC controlled AA instrument orders.
Order Instruction
• I&I is not included, but can be added
• 1 Year SW Upgrade/Phone Assist is an optional add in

G9271AA SpectrAA Base SW Upgrade

Description
SpectrAA Base Software Upgrade for customers with older versions of SpectrAA Base
sof tware. Includes Windows 10 PC.
Note: Need to include GPIB-USB converter (7910051600) for customer with previous
IEEE-GPIB cable.
Order Instruction
• I&I is not included, but can be added
• 1 Year SW Upgrade/Phone Assist is an optional add in

Options for SpectrAA Base Software and SpectrAA Base SW Upgrade

#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide their
own PC and must meet the PC requirements.

#790 Delete Monitor

#890 Delete Printer

9910115700 Kit, GTA Viewing Retrofit AA140240280

Description
GTA camera retrofit kit for 240 and 280 series instruments.

GFAAS Instruments manufactured before Nov2016 with serial numbers before


MY1644xxxxxx will need to add this part number for TubeCAM upgrade.

Page 42 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Requires installation at customer site.

SpectrAA Pro software


SpectrAA Pro software supports:

• AA Duo operation enabling simultaneous flame/vapor and furnace operation from one computer.
• Fast Sequential operation, suitable for fast, multi-element flame determinations using Agilent’s
patented Fast Sequential technologies.
• Internal Standard corrections in flame AA, when operating in Fast Sequential mode, improving
precision and accuracy or allowing correction for sample preparation errors.
• Advanced QC operations offering extended capabilities that allow testing to US EPA and US CLP
protocols. Other international compliance standards can be easily met by customizing QCP using
the simple equation editor

SpectrAA Pro SW Upgrade


Note: this software is included as standard with DUO instrument packages, 240FS (including 240FS
bundles), 280FS and 280Z AA instrument orders
Part Number Description

G9285AA SpectrAA Pro SW Upgrade to v5.6

Description
SpectrAA Pro SW Upgrade. Upgrade for customers with previous versions of SpectrAA
Pro software to the latest version. Includes a Windows 10 PC. Note: Need to include
GPIB-USB converter (7910051600) f or customer with previous IEEE-GPIB cable.

Order Instruction
• I&I is not included, but can be added
• 1 Year SW Upgrade/Phone Assist is an optional add in

Options for SpectrAA Pro SW Upgrade

#695 Delete PC, monitor and printer

Description
Deletes the PC, monitor, printer and all associated cables. Customer must provide their
own PC and must meet the PC requirements.
#790 Delete Monitor

#890 Delete Printer

9910115700 Kit, GTA Viewing Retrofit AA140240280

Description
GTA camera retrofit kit for 240 and 280 series instruments.

GFAAS Instruments manufactured before Nov 2016 with serial numbers before
MY1644xxxx will need to add this part number for TubeCAM upgrade.

Page 43 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Requires installation at customer site.

SpectrAA SW Base to Pro Upgrade


Part Number Description

G9284AA SpectrAA SW Base to Pro Upgrade

Description
Upgrade to SpectrAA Pro. SpectrAA Pro software supports Duo operation, Fast
Sequential operation, Internal Standard corrections, and advanced QC operation.

Order Instruction
• I&I is not included, but can be added
• 1 Year SW Upgrade/Phone Assist is an optional add in

SpectrAA CFR software

SpectrAA CFR software provides an analysis system that assists the user organization to comply with the
US FDA 21 CFR Part 11 requirements covering audit trails, electronic records and electronic signatures.
The SpectrAA CFR software is compatible with Microsoft Windows 10 Pro or Enterprise 64 bit and
requires the latest SpectrAA Pro Software.

Part Number Description

G9272AA SpectrAA CFR S/W

Description
The f ull version of SpectrAA CFR software (includes SpectrAA PRO). For customers
who want to upgrade their system from SpectrAA Base to SpectrAA CFR.
Requires SpectrAA Base 5.6 or greater.
Includes SpectrAA Pro SW + SpectrAA CFR SW.

Order Instruction
• I&I is included
• 1 Year SW Upgrade/Phone Assist is an optional add in
G9273AA SpectrAA CFR S/W – Upgrade

Description
This version supplies SpectrAA CFR only software and is for customers that
currently have SpectrAA Base and Pro who want to upgrade to SpectrAA CFR.
Requires SpectrAA Base and PRO 5.6 or greater.

Order Instruction
• I&I is included
• 1 Year SW Upgrade/Phone Assist is an optional add in

Page 44 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Ordering Instructions for SpectrAA CFR Software


For customers with SpectrAA Base 5.6 who want to upgrade to CFR order the following part
numbers:
• G9272AA SpectrAA CFR S/W

For customers with SpectrAA Base and Pro 5.6 who want to upgrade to CFR, order the
following part numbers:
• G9273AA SpectrAA CFR S/W – Upgrade

For customers with SpectrAA Base or Pro 5.5 or older, or SpectrAA CFR 5.5 or older, order the
following part numbers:
• G9285AA SpectrAA Pro SW Upgrade to upgrade to SpectrAA Base and Pro 5.6
• G9273AA SpectrAA CFR S/W – Upgrade for the latest SpectrAA CFR software
Back to Contents

Page 45 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

IQ/OQ
Up to date information on ordering IQ/OQ services for AA instruments can be found at the
services section of the Field Portal in the Service and Support Quoting Guide, which is
available at the following links:
Upfront Services: here
Aftermarket Services: here

AA PM and OQ Standards Kits


To reduce any quality issues in the AA qualification workflow, Agilent is introducing a new portfolio
of AA PM and OQ standard kits. This portfolio has 3 unique kits that cover each type of AA system –
Flame, Furnace Zeeman and Furnace Non-Zeeman. Each of these kits include multiple pre-diluted
standards that eliminates any potential dilution errors and simplifies the qualification process.
These standards were also manufactured at an ISO 17025 and ISO 17034 facility and are at a
certified reference material quality level. All standards come with a Certificate of Analysis (CoA).

Part Number Description

5799-0003 AA Flame PMOQ Standards Kit


Description
Tailored PM and OQ standards for Flame AAS qualification

Includes
• 2 x 250mL 0.2% HNO3 Blank
• 1 x 50mL 1.0 mg/L Cu in 0.2% HNO3
• 1 x 50mL 2.5 mg/L Cu in 0.2% HNO3
• 1 x 150mL 5.0 mg/L Cu in 0.2% HNO3
• 1 x 50mL 1.0 mg/L Li & 0.38% w/v KCl in 0.2% HNO 3

5799-0009 AA Furnace (non-Zeeman) PMOQ Standards


Description
Tailored PM and OQ standards for non-Zeeman Furnace AAS qualification

Includes
• 1 x 50mL 0.2% Nitric Acid Blank
• 1 x 50mL 0.025 mg/L Copper in 0.2% HNO3
5799-0011 AA Furnace (Zeeman) PMOQ Standards Kit
Description
Tailored PM and OQ standards for Zeeman Furnace AAS qualification

Includes
• 1 x 50mL 0.2% Nitric Acid Blank
• 1 x 50mL 0.025 mg/L Copper in 0.2% HNO3
• 0.066% w/v NaCl in DI Water

* These CRMs are manufactured in an ISO Guide 34 facility and certified in an ISO/IEC 17025 and
17034 testing laboratories. They are supplied with a Certificate of Analysis confirming ISO
conformity, actual concentration values, measurement uncertainty, and NIST traceability.

Page 46 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

From September 1 2021 the services for the 55B are changing.
SYS-AA-140 is no longer valid at POIS for the 55B, the SYS-AA-14- is designated for aftermarket
services on the 50 and 140 AA instruments that have reached EGS.

SYS-AA-55 is the new system number for all services related to the 55B.

Page 47 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

AA 55

Part Number Description


(POIS)
SYS-AA-55 AA 55 Hardware compliance services system
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS SpectrAA Software compliance service system
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)
SYS-AA-55-E AA 55 Hardware Enhanced Features (CFR21)
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS-E SpectrAA Software compliance service system (CFR21)
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)
SYS-AA-55-M AA 55 Flame Only Hardware compliance services system
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS-M SpectrAA Software compliance service system
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)

Page 48 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

AA 240/280 Flame

Part Number Description


(POIS)
SYS-AA-280 AA 240/280 Hardware compliance services system
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS SpectrAA Software compliance service system
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)
SYS-AA-280-E AA 240/280 Hardware Enhanced Features
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS-E SpectrAA Software compliance service system (CFR21)
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)
SYS-AA-280-M AA 240/280 Flame Only Hardware compliance services system
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS-M SpectrAA Software compliance service system
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)

Page 49 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

AA 240/280 Zeeman

Part Number Description


(POIS)
SYS-AA-280Z AA 240Z/280Z Hardware compliance services system
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is
both IQ&OQ on the hardware at installation and is cheaper than separately
including IQ and OQ.
SYS-SW-CS SpectrAA Software compliance service system
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)
SYS-SW-CS-E SpectrAA Software compliance service system (CFR21)
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)

AA DUO

Part Number Description


(POIS)
SYS-AA-DUO AA DUO systems compliance services system
#6N9 Enterprise (ACE) Installation Qualification (hardware)
#6J9 Enterprise (ACE) Operational Qualification (hardware)
#6H9 Enterprise Hardware AIQ (Analytical Installation Qualification) at POIS. AIQ is both
IQ&OQ on the hardware at installation and is cheaper than separately including IQ
and OQ.
SYS-SW-CS SpectrAA Software compliance service system
#6N9 Pro Installation Qualification (software)
#6J9 Pro Operational Qualification (software)
#6H9 Sof tware Pro AIQ at POIS (bundled AIQ is cheaper than separate part numbers for
IQ and OQ)
SYS-SW-CS-E SpectrAA Software compliance service system (CFR21)
#6N9 Base/Pro Installation Qualification (software)
#6J9 Base/Pro Operational Qualification (software)
#6H9 Sof tware Base/Pro AIQ at POIS (bundled AIQ is cheaper than separate part
numbers f or IQ and OQ)

Page 50 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Customer Education Services


Up to date information on ordering Customer Education services can be found at the
Product Information section of the Field Portal in the Agilent University area, which is
available at the following link here

Please Note:
• Customer Education products are moving to a “Training Credits” model. The
appropriate number of training credits need to be purchased for the type of training
course the customer is interested in. Example: 3-day classroom course requires
1800 training credits. This means 18 x R3999B.
• There is an array of AAS training courses on offer. Some are classroom, some are
on line with Agilent University. Please go to the following Agilent site to check out
what is available in your country. Agilent University Lookup Tool and see AAS
training courses matrix to understand the number of credits required fo r each course.
• After training credits are ordered, the customer will receive an automated email on
how to redeem these training credits. The customer will need to go to Agilent
University register for the training but please ensure that the training is available in
your country prior to ordering. For more information on how the customer will
redeem credits please review Process around Training Credits for customer
education here.

If you wish to review the courses you can go to the Agilent University Lookup tool to see the
courses currently available in your country.

AAS training courses, training credits required and Countries offered

Course Name Credits Country


AA-FLM-2103c - Agilent Flame AA / 400 Australia, Austria, Belgium, Brazil,
SpectrAA Ver. 5 Operation and Canada, China, Denmark, Finland,
Maintenance - 1 Day France, Germany, India, Ireland, Italy,
Japan, Korea, Luxembourg, Malaysia,
Mexico, Netherlands, New Zealand,
Norway, Poland, Russia, Singapore,
Spain, Sweden, Switzerland, Taiwan,
Thailand, United Kingdom, United
States
MFA-PREP-3301c - Sample preparation for 800 Brazil
metal analysis - 1 Day (PREPAM-MET)
AA-0GEN-2000c - NTC AAS Training 1,200 China
Course - 2 Day (NTC-TEST-AAS)
AA-FLM-2000cV2 - Techniques of Agilent
Flame AA Spectroscopy Version 2 - 3 Day 1,500 United States
(R2192Av2)
AA-FLM-2000c - Techniques of Agilent Brazil, France, Germany, Mexico,
Flame AA Spectroscopy - 3 Day (R2192A) 1,500 Singapore, United Kingdom

AA-FLM-2002c - Techniques of Agilent 500 Taiwan


Flame AA Spectroscopy - 1 Day (R2192A)

Page 51 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

AA-FURN-2000c - Techniques of Agilent Brazil, France, Germany,


Furnace AA Spectroscopy - 3 Day 1,500 Singapore, United States
(R2194A)
AA-FURN-2001c - Techniques of Agilent
Furnace AA Spectroscopy - 1 Day 500 Taiwan
(R2194A)
AA-0GEN-2100c - Agilent Flame & Furnace 1,500 Switzerland
AA Operation - 3 Day (R2197A)
AA-0GEN-2101c - Agilent Flame & Furnace 2,000 China
AA Operation - 4 Day (R2197A)
AA-0GEN-2102c - Agilent Flame & Furnace 2,500 France
AA Operation - 5 Day (R2197A)
AA-FLM-2200cV2 - Agilent Flame AA
Maintenance & Troubleshooting Version 2 - 600 United States
1 Day (R2193Av2)
AA-FLM-2200c - Agilent Flame AA
Maintenance & Troubleshooting - 1 Day 600 Brazil, Germany
(R2193A)
AA-FLM-2201c - Agilent Flame AA
Maintenance & Troubleshooting - 2 Day 1,200 France
(R2193A)
AA-FURN-2200c - Agilent Furnace AA
Maintenance & Troubleshooting - 2 Day 1,200 France
(R2196A)
AA-FURN-2201c - Agilent Furnace AA
SpectrAA ver.5 Operation and maintenance 400 Japan
- 1 Day
AA-0GEN-3100c - Agilent Furnace AA 1,800 France
Advanced Operation - 3 Day (R2195A)
ICPOES-0GEN-1002c - Laboratory Skills for 300 Japan
Inorganic Analysis - 1 Day

Important Customer Training Part numbers

Part Number Description

R3999B 100 Agilent University training credits


H2149A Application Consulting
Options
#001 One day on site consulting
#002 Two days on site consulting
#003 Three days on site consulting
#004 Four days on site consulting
#005 Five days on site consulting
#010 Ten days on site consulting

Service Contract information

Page 52 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Up to date information for Agilent Advantage service contracts can be found at the services
section of the field portal at the following link:

Point of Instrument Sale Services information: here


Aftermarket services information: here

From September 1 2021 the services for the 55B are changing.
SYS-AA-140 is no longer valid at POIS for the 55B, the SYS-AA-14- is designated for aftermarket
services on the 50 and 140 AA instruments that have reached EGS.

SYS-AA-55 is the new system number for all services related to the 55B

Part Number Description

SYS-AA-55 AA 55 services system


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

SYS-AA-55-E AA 55 services system Enhanced Features


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total

Page 53 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#8D2 Extended Warranty 2 years total


#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

SYS-AA-55-M AA 55 services system Flame only


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

Page 54 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

SYS-AA-280 AA240/280 services system


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

SYS-AA-280-E AA240/280 services system Enhanced Features


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr

Page 55 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#9C4 CrossLab Bronze Gov't/Academia 4yr


#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

SYS-AA-280-M AA240/280 services system Flame only


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

SYS-AA-280Z AA240/280 Zeeman services system


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total

Page 56 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

#8R1 CrossLab Silver 1st year uplift


#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Part Number Description

SYS-AA-DUO AA DUO services system


Options
#8C1 CrossLab Bronze 1st year uplift
#8C2 CrossLab Bronze 2 years total
#8C3 CrossLab Bronze 3 years total
#8C4 CrossLab Bronze 4 years total
#8C5 CrossLab Bronze 5 years total
#8D2 Extended Warranty 2 years total
#8D3 Extended Warranty 3 years total
#8D4 Extended Warranty 4 years total
#8D5 Extended Warranty 5 years total
#8R1 CrossLab Silver 1st year uplift
#8R2 CrossLab Silver 2 years total
#8R3 CrossLab Silver 3 years total
#8R4 CrossLab Silver 4 years total
#8R5 CrossLab Silver 5 years total
#9C2 CrossLab Bronze Gov't/Academia 2yr
#9C3 CrossLab Bronze Gov't/Academia 3yr
#9C4 CrossLab Bronze Gov't/Academia 4yr
#9C5 CrossLab Bronze Gov't/Academia 5yr
#0L1 CrossLab Preventive Maintenance 1yr
#0L2 CrossLab Preventive Maintenance 2yr
#0L3 CrossLab Preventive Maintenance 3yr
#0L4 CrossLab Preventive Maintenance 4yr
#0L5 CrossLab Preventive Maintenance 5yr
#0L9 CrossLab Preventive Maintenance

Page 57 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Appendix –Instrument and Accessory Contents

Flame Instruments
All flame instruments include the following items:

• Automatic wavelength and slit selection


• PC
• GPIB-USB Converter
• Color Printer
• Monitor
• Universal spray chamber with standard O-rings (can be changed using ordering options)
• Air/Acetylene burner (can be changed using ordering options)
• Chimney
• Sample Tray
• Spray chamber stand
• Operation manual
• Flame AA Analytical Methods book
• Poster
• Spare fuses
• Spare glass impact beads
• Burner cleaning cards
• Spray chamber tools
• Nebulizer cleaning wire
• Spare O-rings for atomization system
• Capillary tubing

Notes:

• The 55B AA includes the Wide Range PMT (type R446 covers 185-900 nm).
• The 280FS includes UltrAA lamp looms.
• 240FS/GTA120/PSD120/UltrAA System includes the list of parts above as well as the
parts included with the GTA 120

See the Instrument Software matrix for software included with each instrument.

Graphite Furnace Instruments


All graphite furnace instruments include the following items:

• PC
• GPIB-USB Converter (7910051600)
• Printer
• Monitor
• UltrAA lamp looms
• Automated wavelength and slit selection

Page 58 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

• Wide range PMT


• Automated 4 lamp selection on 240Z models
• Automated 8 lamp selection on 280Z
• Zeeman Background Correction
• SpectrAA Base Worksheet style software on the 240Z models
• SpectrAA Pro software on the 280Z
• Operation manual
• Poster
• Mouse mat
• Keyboard overlay
• Spare f uses
• Pyrolytically coated partitioned graphite tubes (Pack of 10)
• Spare capillary assembly
• Drain tubing
• Sample vials (1000 x 2 mL vials)
• Plastic Beakers PSD120 (Pack of 5)
• Tubing and connectors for cooling water supply
• All gas hoses, cables and connectors
• GTA Camera

Duo instruments
Parts included with Duo instruments are a combination of the parts su pplied with the Flame and
Graphite Furnace instruments.

SPS 4 Autosampler
Includes:

• SPS 4 base unit including single port wash reservoir kit


• 250 x Polypropylene 50ml sample tubes
• 250 x Polypropylene 16.5ml, 17mm o.d. x 130mm tubes
• 4 x Solvaflex grey/grey 3 bridged PVC peri pump tubes
• Power supply AC-DC switching
• 2m USB cable
• 4 x Sample racks. 60 position for 16mm od tubes.
• Sample probe kit 0.8 mm ID Fluoroplastic sleeved probe
• 1 standards rack 34 position
• Autosampler user manual

Page 59 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

VGA-77
Includes:

• Pump unit
• AA hydride module including gas-liquid separator,
• Cell holder to fit Agilent Mark 7 Air/acetylene burner
• Reagent containers
• All tubing, hoses and connectors plus a spares kit
• Operation manual
• 2 Quartz cells
• Power cables

SIPS 10 and SIPS 20


Includes:

• SIPS 10 or SIPS 20
• Pump unit
• Constant pressure vessel for diluent
• 1 L bottle for stock solutions
• 1 pack of pump tubes (2 for the SIPS 20)
• 1 pack of pump bands (2 for the SIPS 20)
• Power cables
• IEEE cable
• SIPS communication (interconnecting) cable

GTA 120
Includes:

• GTA 120 power supply module


• PSD 120 Programmable Sample Dispenser
• Carousel and cover
• 1 Litre rinse reservoir
• Pyrolytically coated partitioned graphite tubes (Pack of 10)
• Spare capillary assembly
• Drain tubing
• Sample vials (1000 x 2 mL vials)
• Plastic Beakers PSD120 (Pack of 5)
• Tubing and connectors for cooling water supply
• All gas hoses, cables and connectors

Page 60 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Back to Contents

Appendix – PC Requirements

These are the minimum and recommended PC specifications for SpectrAA Base, Pro and CFR
software.

Note: If using a PCI-IEEE communications card the PC requires a full height PCI
expansion slot.

Note: During installation of SpectrAA software, Windows Microsoft .NET Framework 3.5
is needed and is pre-installed with the PC that we supply. If PC is purchased by the
customer independently, be sure to mention that .NET 3.5 is a prerequisite to avoid any
problems during the installation of SpectrAA software.

Note: For CFR installations, 8GB or more RAM is recommended.

Minimum computer configuration


Intel 2 GHz processor 64 bit processor; 4 GB RAM; 17 inch Super VGA monitor; graphics card
supporting 1280 x 768 resolution; minimum of 250 GB available hard disk space; at least 2 USB
ports, at least one serial (RS 232) port and Microsoft Windows 10 Professional 64-bit operating
system with Microsoft .NET Framework 3.5 installed.

Recommended computer configuration


Intel® Xeon® Quad-Core Processor (2.66 GHz); 8 GB RAM; 19 inch Super VGA monitor; graphics
card supporting 1024 x 768 resolution; 500 GB hard disk; 24 speed CD -ROM drive; 16 bit Sound
card and speakers; at least 2 USB ports, two serial (RS 232) ports and Microsoft Windows 10
Prof essional 64-bit operating system with Microsoft .NET Framework 3.5 installed.

PC for Agilent AAS Instruments


Agilent AAS instrument bundles and software/PC bundles for AAS models that include a desktop
PC f eature the HP model Z2G9 PC with Windows 10 Professional 64-bit operating system and
Microsoft Framework 3.5 installed, HP 21.5” monitor and HP 8210 colour inkjet printer.

Desktop PC specifications:

Manuf acturer: Hewlett-Packard


Product line: HP Z2G9 Guide
Form Factor: Small Form Factor Picture
Operating System: Windows 10 Prof essional 21H2, 64 bit only.
(English, Japanese, Chinese)
Processor Type: Intel® Core i5 i5-12500
Processor Speed: 3.0 GHz, 18MB cache
Memory: 8GB DDR5-4800 nECC RAM
Hard Disk: 512GB 2280 PCIe-4x4 NVMe Value M.2 SSD
Optical Drive: 9.5mm Slim DVDRW Writer

Page 61 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

Graphics: Intel UHD Graphics 770


Audio: HD Integrated Audio (Realtek ALC3252); 1 universal audio jack; 1
audio line out
Communications: 2 Network Interf ace Cards (Ethernet) incl. 1x Integrated Intel
I219LMPCIe GbE Controller and 1x HP Flex 1GbE Single Port NIC
Front Ports: (2) Type-A SuperSpeed USB 10Gbps signalling rate port (1 charge
port supports up to 5V/2.1A), (2) Type-A SuperSpeed USB 10Gbps
signalling rate port, (1) Type-C SuperSpeed® USB 20Gbps signalling
rate port (charge supports up to 5V/3A)
Rear Ports: (2) DisplayPort 1.4, (3) USB-A 480Mbps ports, (3) USBA 5Gbps
ports, (1) HP serial port adapter
Peripheral: HP USB Optical Mouse / HP No Keyboard Option
Dimensions: 338w x 380l x 100h mm (as pictured)

Monitor:

HP P22 G4 22 FHD Guide


Picture
Native Resolution: 1920x1080 @ 60 Hz
only.
Viewable Area: 21.5 in (53.8cm)
Pixel pitch: 0.247mm
Brightness Ratio: 250 cd/m2
Contrast Ratio: 1000:1 static, 8000000:1 dynamic
Response Time: 5 ms gray to gray
Aspect Ratio: 16:9
Cables in box: 1 HDMI; 1 VGA, 1 AC power cable
Display Inputs: 1 DisplayPort 1.2 (with HDCP support); 1 HDMI 1,4 (with HDCP
support; 1 VGA
Power Supply: Internal
Input Power: 100-240 VAC at 50/60 Hz

Printer:
Hewlett Packard Color inkjet printer Of f iceJet Pro 8210 series Guide
Picture
Print Speed: Black – up to 22 ppm black only.
Color – up to 18 ppm color
Print Resolution: Black – up to 1200 x 1200
optimized dpi on plain paper f rom 600 x 600 input dpi
Color – up to 2400 x 1200 optimized dpi on HP advanced photo
paper, 600 x 600 input dpi
Monthly Duty Cycle: Up to 30,000 pages
Ink Type: Pigment based (black and color)
Cartridge Capacity: Black – up to 2,000 pages (hi-cap)
Color – up to 1,600 pages (hi-cap)
Memory Standard: 256 MB DDR3
Print Languages: HP PCL 3 GUI, HP PCL 3 Enhanced
Processor: 360MHz ARM R4
Input Capacity: 250 sheet input tray
Output capacity: 150 sheet output tray
Connectivity: Hi Speed USB 2.0, Built in wired Ethernet 10/100Base-TX (RJ45)
networking, Built in wireless 802.11b/g/n networking. WiFi direct.

Page 62 of 63 DE67382444
Agilent AAS Ordering Guide March 2023

DE: 8944675926

Page 63 of 63 DE67382444