The document is a concrete cube test report from CAST Laboratories Pte Ltd for a project by China Jingye Engineering Corporation Ltd. It details the compressive strength and density of concrete samples taken from a column and kicker, with results showing compressive strengths of 57.1 N/mm2 and 58.6 N/mm2. The report includes testing conditions and disclaimers regarding the use of the report and the laboratory's liability.

Uploaded by

paidbywah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views1 page

BASIC_C655A_13_12234

The document is a concrete cube test report from CAST Laboratories Pte Ltd for a project by China Jingye Engineering Corporation Ltd. It details the compressive strength and density of concrete samples taken from a column and kicker, with results showing compressive strengths of 57.1 N/mm2 and 58.6 N/mm2. The report includes testing conditions and disclaimers regarding the use of the report and the laboratory's liability.

Uploaded by

paidbywah
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

CAST LABORATORIES PTE LTD

17 TUAS AVENUE 8 SINGAPORE 639232


Tel: 6801 6000 Fax: 6801 6004
Website: www.castlab.com.sg
Business Reg No 198100052N

CONCRETE CUBE TEST REPORT


TEST METHOD: Density BSEN 12390-7:2019 (by calculation, using checked, designated dimensions)
Compressive Strength BSEN 12390-3:2019

CUBE DETAILS AS FURNISHED BY COMPANY: JOB NO: C655A/13/12234


CHINA JINGYE ENGINEERING CORPORATION LTD (S`PORE) DATE: 04/08/2024
21 BUKIT BATOK CRESCENT, #19-77, WCEGA TOWER SINGAPORE 658065 PAGE: 1 OF 1

Project: CONTRACT CR101 - DESIGN, CONSTRUCTION AND COMPLETION OF CHANGI EAST DEPOT

Structural Element Cast: COLUMN & KICKER (STB2-GL24/L COLUMN & GL 11/C-KICKER)

Grade of Concrete: 50 SBC501F4


Cement/Admixture (If Any):
Supplier: Pan United Concrete (PUC ) TESTED AT: 17 Tuas Ave 8

DATE RECEIVED: 05/07/2024 DATE CAST: 30/06/2024 DATE TEST: 29/07/2024 AGE AT TEST: 29 DAY(S)
DENSITY
COMP
GIVEN WATER MAX
STRENGTH
SLUMP DIMENSION SATURATED LOAD
(N/mm2)
SAMPLE MARK (mm) (mm) (Kg/m3) (kN) REMARKS
Z1/STB2-GL24/L/CO&11C- 600-800 (FR) 150x150x150 2380 1284.1 57.1
KI/10952C
Z1/STB2-GL24/L/CO&11C- 600-800 (FR) 150x150x150 2360 1317.4 58.6
KI/10952D

*Measured dimension (> ±1% of nominal) Curing of received sample(s) at 25±5°C

WITNESSED BY:
C.C. This Report is issued under the following conditions:
CAST Laboratories Pte Ltd
1. This is a Test Report and not a CAST Laboratories Certificate of Quality. It
only applies to the sample of the specific product given at the time of its
testing.
2. CAST Laboratories testing does not constitute a recommendation for or
endorsement of, the product or material tested.
3. The report shall not be reproduced in part or full unless approval in writing
has been given by CAST Laboratories.
4. CAST Laboratories agrees to use reasonable diligence in the manner of
performing the test but no warranties are given and none shall be implied
directly or indirectly relating to CAST Laboratories services, test results or FOO SIANG MENG
facilities. In no event shall CAST Laboratories be liable for collateral, special or
consequential damage. MANAGER
TESTED BY: Azizul

The results reported herein have been performed in accordance with the laboratory's terms of accreditation under the Singapore Accreditation Council - Singapore Laboratory Accreditation Scheme/
The report shall not be reproduced wholly or in parts unless approval in writing has been given by CAST Laboratories Pte Ltd.

You might also like