pennekamp operating instruction
pennekamp operating instruction
INDEX
1 GENERALITIES .......................................................................................................................................... 5
1.1 Spraying Unit Layout ............................................................................................................................. 6
Phase diagram ................................................................................................................................................. 6
1.2 good/bad rows ........................................................................................................................................ 7
6 OPERATING ELEMENTS.................................................................................................................. 12
6.1 Function Keys of the Operator Panels OP77 ........................................................................ 12
6.2 operating elements at the second Operation Position ................................................................. 13
6.3 Button Emergency-Off ...................................................................................................................... 13
page 1 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
All set values can be modified immediately at the Operator Panel KTP600 also during the
spraying cyle ..................................................................................................................................................... 21
The following set values mentioned below are only effective when the spray rail has reached its
initial position (Position 1). ............................................................................................................................ 21
7.6.2 set value for light barrier operation ............................................................................................. 23
set value LIGHT............................................................................................................................................ 23
set value LIGHT............................................................................................................................................ 23
Input .............................................................................................................................................................. 23
set value LIGHT............................................................................................................................................ 23
7.6.3 set value for continuous operation .............................................................................................. 24
superviosion LIGHT BARR.......................................................................................................................... 24
7.13 menu HELP help for the adjustment of the spray rail ............................................................. 34
7.13.1 menu structure of menu HELP .................................................................................................... 35
menu HELP ................................................................................................................................................... 35
menu HELP ................................................................................................................................................... 35
input toerance ............................................................................................................................................... 35
STARTSIGNAL : 00 ms....................................................................................................................... 35
menu HELP ................................................................................................................................................... 35
input .............................................................................................................................................................. 35
minimum GAP: 00 ms ......................................................................................................................... 35
page 2 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
page 3 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
1 GENERALITIES
The spray rail serves to spray glass articles at the cold end of the
annealing lehr.
The spraying of the glass items improves their gliding quality and
reduces the defects which may be caused by friction.
The spraying unit displaces one or various spray guns, which are
moving above or between the glass article rows.
The speed of this movement is infinitely variable via an asynchronous motor which is
controlled by a frequency converter.
So as to prevent any coating product from entering the articles‘ mouth, spraying is
executed in-between the glass rows which is possible due to the inclined position of
the drive unit and the light barrier regulation.
In case the light barrier cannot detect proper row distances, as for example some
bottles have been aligned incorrectly, this row will be
sprayed with gun lifted up or no spraying is executed, depending on the
respective adjustment. The start signal then is given by an internal impulse transmitter
which is corresponding to the time cycle of the article rows.
The operation and fault indication of the spray rail is made at the KTP600.
The spray rail is switched on via the main switch 5S1, the green signal lamp
OPERATION is flashing in cycles of about 1 second, thereby signalising that the spray
rail is ready for operation.
In case there is no switching off disturbance, the spray rail can be switched on for
operation by pushing the key K1 at the Operator Panel KTP600 (first operating
position)
or the button START (second operating position) from STOP STATE to OPERATION
STATE.
At the operator panel KTP600 of the spray rail two operating modes can be adjusted:
Continuous operation
Light Barrier Operation
At the Operator Panel KTP600 it is possible to adjust in the operating mode light
barrier whether a spraying of the article rows is allowed with spray gun lowered down
only. Thereby it is avoided that any spray product will be sprayed into the articles‘
mouth.
2.Operating Pos.
Position 1 Position 2
1.Operating Pos.
Displacement Way
rweg
Phase diagram
Magnetic valve
Delay Delay
page 5 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
Spray gun
page 6 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
2 Operating Modes
STOP
The spray rail is switched on by the main switch and can be switched into the operation state
1
(continuous operation or light barrier operation by the button „K1“ at the operator Panel KTP600 or
by the button „START“ at the second operation position.
Difference is made between bad and good rows in the light barrier operation
With the adjustment at the Operator Panel KTP600 you can chose whether every row or only good rows
shall be sprayed.
page 7 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
Die Betätigung der ESC-Taste bewirkt das Einschalten der Sprühpistole. Jetzt kann in Posi.1 oder
Posi 2. Der Sprühstrahl und die Intensität eingestellt werden.
Durch drücken und halten der Taste Lampentest leuchten alle Signallampen der Spritzbrücke auf.
Somit kann eine defekte Leuchte ermittelt werden.
Durch Betätigung der MAIN-Taste gelangen Sie ins Hauptbild der Visualisierung der Spritzbrücke.
Not acknowledged Fault messages are blinking with the system’s blinking frequency.
Acknowledging of each fault message at the KTP600 is done when the operator pushes
the ACK-KEY.
page 8 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
4 SIGNAL LAMPS
- Continuous light
The spray rail is in OPERATION condition and can start at any time after a start
impulse.
Quick blinking
The operation mode light barrier is selected and the average temporary distance of
the article row is calculated by the PLC. the spray rail starts after
start impulse has arrived.
This signal lamp signalises faults at the unit or within the electric regulation.
TROUBLE SHOOTING
When a fault message arrives, this is designated with + as “arriving message” and shown
at the display as blinking message as long as it is acknowledged by the operator at the
Operator panel KTP600 with the acknowledge key “ACK”. Still existing disturbance
messages are indicated at the Operator Panel KTP600 with the illuminating LED of the
acknowledge key. When the disturbance message is no more existing (fault message
acknowledged by the operator) this is designated as gone with “-“.
Attention !
Fault messages are reset only then if they are acknowledged with the button “ACK”
In case of failure of the KTP600 the disturbance can be acknowledged by the adjusting
switch SPRAYING/button START by short pushing to the right.
page 9 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
6 OPERATING ELEMENTS
6.1 Function Keys of the Operator Panels OP77
Switching ON: When the spray rail was switched on by the main switch and
when there is no fault with switching off effect, the spray rail can
be switched on by pressing the key „F1“. (Condition: the spray
rail was switched off). The lighting up of „F1”-LED and signal lamp
OPERATION signalise that the spray gun is switched on.
Switching OFF: After pushing the key „F1“ the spray rail is switched off when it
has reached the initial position (Initiator 0-point). (Condition: the
spray rail was switched on). The „F1“-LED and the green signal
lamp OPERATION pass over into blinking (cycle frequency 1s). The
spray rail is in STOP condition.
ACTIVATE: When the spray rail is stopped, „TEST GUN SPRAYING“ can be
activated via the key “F2“and the LED lights up. So the
adjustment of the spray gun can be done.
DEACTIVATE: When the key „F2“ is again pushed or the spray rail is switched
on, the test is deactivated.
Occurring faults are indicated by flash light of the red signal lamp and
shown in the clear text at the OP77.
By pushing the key „ACK“ the red lamp passes over into steady light,
in case the fault is still present. The red signal lamp only extinguishes,
when the fault has been removed. At the KTP600 the number of faults
which have arrived and which are still existing are indicated in the
submenu fault messages.
page 10 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
This chapter describes the operating elements at the second Operating Position.
In case there is no trouble with switching-off effect, the spray rail can be switched on
by turning the adjusting switch SPRAY / button START to the left.
The spray rail is moving then slowly unto the position „initial position“, with the guns
lifted up. The lighting up of the green signal lamps OPERATION shows that the spray
rail is switched on and will carry out a spray cycle after having reached the position
„initial position“ at next start signal.
By turning the adjusting switch SPRAY / button START to right the spray rail the spray
nd
rail moves into position 2 „2 operating position“ during the cycle. The movement is
stopped whereby the spray guns remain switched ON in order to enable an exact
spraying adjustment.
When this button is pressed the spray rail is immediately switched off. By turning and
pulling out this switch can be released again.
ATTENTION:
When working at the spray rail this button always
should be pushed!
page 11 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
The KTP600 is an operating panel allowing to visualise processes. Due to the limited
dimension of the LC-display a picture hierarchy was established for the operating of the
spray rail to allow the operator to change within the various pictures.
Message Level
The message level is the highest level at the OP. In the message level existing operating
and disturbance messages as well as system messages are shown. After starting, the OP
changes into the message level, when a system or disturbance message exists.
The disturbance and operating messages are released by the PLC and transferred to the
KTP600. If a message is existing, the KTP600 recognises the respective message as come,
and after the message has been reset it is recognised as gone.
-Fault Messages indicate faults and have to be acknowledged at the KTP600 due to their
importance.
e.g. Button Emergency-off 9S2.1/9S2.2
Prox. switch 0-position faulty – 12B4
Check Main contactor -9K4
-System messages are released by the KTP600 and inform about operation states of the KTP600
and about fault operation (see more details in the manual Operator Panel KTP600).
Picture level:
In the picture level functions (e.g. input length of the spray way) are selected and operated.
The operator can see actual process values, enter and modify values (which have to be
acknowledged then with the ENTER key. Changing between the various levels can be done
via the Symbolkeys.
page 12 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
Bildanwahl: Störungsanalyse
Bildanwahl: Einstellungen
page 13 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
Indication Spraying
GUN ↑ = = Spraying only with gun UP
(Continuous
Operation)
GUN ↓ = = Spraying only with gun down
(Light Barrier only good rows are
sprayed))
GUN ↑↓ = Spraying with gun UP and DOWN-
(Light operation spraying each row)
page 14 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
The contents of the alarm memory can be shown via the arrow keys “Up/Down”
The message text of the marked event can be shown via the arrow keys “right”.
In the submenu “Number” all alarms which are in the event memory are divided up in
- total alarms
still existing alarms
page 15 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
A correct input of the main speed (V) in % for the spray movement is necessary to make
sure that the spray guns remain in the middle between two rows during the whole cycle.
The main speed as well as the adjustment of the lateral displacement can be calculated by
the PLC in the menu CALCULATION by means of
Calculation by PLC.
page 16 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
01:
spray each ROW
Input number of rows which should be sprayed at one travel
Input = 1 one time spraying with one gun in each row
Input = 2 two time spraying with two guns in each row (so that each row is
sprayed in the double spray time
The input of the DRIVE WAY is done in the menu “Input of Set values” by entering the
length of the drive way in cm.
02:
ARTICLE / MINUTE: Input the number of articles per minute coming from the
IS-machine)
(Maschinenleistung pro Minute)
ARTICLE / ROW: Input the number of articles per row in spraying direction
(Artikelanzahl / Reihe)
Input distance article rows in mm. See chapter 1.2 (good/bad rows).
By pushing the function key „F2“ (CALC) the calculation is activated. After the calculation
is ready. screen changes into the menu “result calculation”. The “menu calculation is
finished with the function key “F4” (ESC).
01: The output value for the speed is not taken over automatically by
the PLC. The value must be entered manually in the menu „Adjust
set values“.
The output value inclined position indicates the adjust value in mm
for the lateral displacement.
Scroll into the next screen with button F4.
02: The output value for the inclined position is directly converted into
adjust values for the graduation at the hand wheel (black and red
pointer)
(password level 1)
7.6.1 Set Values for light barrier operation and continuous operation
S02: Input length of the DRIVE WAY in cm.
-upper limit = Depending on the constructional dimensions of the spray rail, the
maximum input is limited.
When advancing to the second operation position (spray movement from pos. 1 to
pos. 2) the switching-on of the spray gun in pos. 1 is delayed by the amount,
which was adjusted at the operator panel KTP600.
When returning to the initial position (spray movement from pos. 2 to pos. 1) the
switching off of the spray gun in pos. 1 takes place earlier in relation to the
amount, which was adjusted at the operator panel KTP600.
Example:
Input = 100 cm
Exactly 100 cm driveway starting from position 1, without spraying
Largest Input = 200 cm
Lowest Input = 0 cm
Beim Fahren vor zur 2.Bedienstelle (Sprühbewegung von Position 1 nach Position 2)
schaltet die Sprühpistole um den im Operator Panel KTP600 eingegebenen Wert, in der
Position 2, eher aus.
When advancing to the second operation position (spray movement from pos. 1 to
pos. 2) the switching-on of the spray gun in pos. 2 is delayed by the amount,
which was adjusted at the operator panel KTP600.
When returning to the initial position (spray movement from pos. 2 to pos. 1) the
switching- off of the spray gun in pos. 2 takes place more early in relation to the
amount, which was adjusted at the operator panel KTP600.
Example:
Input = 100 cm
Exactly 100 cm driveway starting from position 2, without spraying
Largest Input = 200 cm
Lowest Input = 0 cm
Attention: When modifying the drive speed of the spray rail, the input values of
SPRAYING have to be adapted eventually.
page 19 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
page 20 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
Länge Fahrweg
Geschwindigkeit
Position 1 ohne Sprühen
Position 2 ohne Sprühen
Sprühen bei Anlauf eher ein
Largest Input = 99
Lowest Input = 5
page 21 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
01: actual gap: Display shows the real value of the actual gap between
1
two rows in /10 of a second. (light duration of light barrier).
difference gap:
Time difference between the actual gap and the
1
gap before in /10 of a second.
02: actual start sig:
Display shows the time between two start signals
in 1/10 of second.(Signal change of light barrier from light to dark).
difference start sig:
Difference start signal is the temporal difference between the
values of start signal which were measured actually and before.
This output value serves as orientation help for the
Input Difference Start Signal.
03: time cycle rows:
Time cycle article rows is the temporal article distance which has
been calculated by the PLC after the measuring out of four good rows.
This values corresponds to the internal generator
bad rows: Number of bad rows, at which the measured gap is smaller
than the minimum gap (Input Operator Panel KTP600)
(Eingabe HELLDAUER min. Lücke).
The set values for another production can be memorised as recipe in the Operator Panel
and be called in again if necessary. The user will give a name to each data file (production)
to enable better finding back. New data files can be re-filed and also copied.
page 22 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
In the menu DATE / TIME the date and the time will be put in by using the key “F1”.
By pressing key “F2” the correct input will be transmitted to the PLC.
Change Date
Position the cursor on the input for the day. Press “SHIFT” for starting the input. By
using the cursor keys “UP” and “DOWN” you could choose the correct day. Afterwards
please press the cursor key “RIGHT” to go to the input for the date. Put in the date by
using the figure keys. Acknowledge your input by pressing the “ENTER” key.
Change Time
Position the cursor by using the cursor key ”RIGHT” at the input for the time. By using
the figure keys the time could be put in. Acknowledge your input by pressing the
“ENTER” key.
To go back to menu DATE / TIME you must push the “ESC” key.
To transmit the edit date and time to the PLC, please press “F2”. The date and time is
now stored and transmitted.
Im Untermenü Einstellungen lassen sich die Benutzerverwaltungen, Sprachen Datum/Uhrzeit einstellen und die
Runtime stoppen.
Achtung !
Es wird für die Einstellung der Helligkeit und der Gerätesprache Paßwortebene 9 (höchste Ebene)
eingegeben
page 23 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
It is shown at the display of the Operator Panels KTP600 whether an option is released or
blocked. .
8 START UP
page 24 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
The spray rail is switched on via the main switch (signal lamp OPERATION s flashing)
Disturbance signals shown at the KTP600 are acknowledged with the ACK button.
Enter the displacement way of the spray rail in cm in the menu Enter Set Value.
Calculate the adjustment for the inclined position and adjust it at the hand wheel.
The main speed as well as the adjustment for the inclined position can be calculated
in the menu CALCULATION of the PLC. The value for the speed is not taken over
automatically by the PLC (see menu Calculation).
Choose the desired operating mode (continuous operation or light barrier) at the
KTP600 and enter the speed.
Adjust the light barriers and reflectors or the guns parallel to the article rows in a way
that the guns are in the middle between the rows when starting.
At various light barriers and reflectors install them in a way that the distance between
the two light barriers or the reflectors are corresponding to the distance of the article
rows on the annealing lehr belt.
For alignment of the light barrier locate the reflector over the upper edge of the
housing. When the red light spot is in the middle of the reflector, the alignment is
optimal.
Estimate the time for the minimum gap (light duration of the light barrier) between two
article rows and enter it at the Operator Panel KTP600 (in menu Operation or in the
menu Enter Set Values.
Start the spray rail over the key K1 at the KTP600, the „K1“-LED lights up and the
signal lamp OPERATION flashes (cycle approx. 100ms), the temporal average value
of the gap and the temporal article distance out of four good rows is calculated, When
the calculation is ready, the signal lamp OPERATION lights up in continuous light and
the minimum gap calculated by the PLC is indicated at the Operator Panel KTP600 in
the menu Operation.
Adjust the light barriers and reflectors or the guns parallel to the article rows in a way
that the guns are in the middle between the article rows when starting.
Displace the carriage on the opposite side in a way that the guns are in the middle
between the rows when moving back.
Eventually the main speed has top be adapted in a way that the guns remain in the
middle between the rows during the whole cycle.
The operator has the possibility, to select a help menu for the adjustment
of the spray rail (see menu HELP) at the operator panel KTP600.
page 25 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
page 26 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
page 27 of 28
el-CES650-II-SPHF34_32-KTP600-en.docx
ERNST PENNEKAMP Operating Instructions
Cold End Coating Unit CES650/2-S7
Reason: no cooling
Removal: Check air-condition –7M6
page 28 of 28