5HGJAD
5HGJAD
Commercial
generator set
TM
Quiet Gasoline
Series
QG 5500 EFI
Features and benefits Weight, size and sound level
• First EFI (electronic fuel injection) generator Weight: 288 lbs (131 kg)
set in its class
• EFI provides improved hot and cold start Size: Length 33.6 in (853 mm), width 22.2 in
capability (563 mm), height 16.7 in (425 mm)
• Integrated hydraulic pump option (pictured) Sound: 64 dB(A) at 10 ft (3 m), typical installation,
• Quietest and lowest vibration generator set in
full load
its class
• Integrated housing design
• Enclosed muffler for ease of installation
• Self-diagnostic capability to simplify
troubleshooting
• Runs two ACs
• Digital regulation for voltage stability as loads
change
• Electronic governor for voltage stability and
frequency control
• 2-year limited warranty, 5-year drive warranty
• Instant one-touch stop switch at 2400 r/min. Air flow includes engine, generator set and
• Electronic ignition control cooling air flow
• Self diagnostic capability Fuel system:
• Hour meter • Replaceable dry element air cleaner
• Battery charging - 5 A • Gasoline side-draft throttle body.
• Remote disable/continuous stop • Remote mount electronic fuel pump with positive fuel
• Start and run without AC output - engine run only shutoff (45 psi), maximum fuel lift 3 ft (0.9 m)
• Enclosed muffler provides noise reduction and ease of 3
• Combustion air volume: 60 Hz: 17.2 ft /min (0.53
installation 3
m /min) at 2400 r/min
• Sound-attenuated housing Starting system: Remote, 12 V, negative ground;
• Waterproof remote connector automotive type starter with steel pinion and ring gear,
• Heavy-duty solenoid shift starter automatic start disconnect, connector for remote start
• Long-life fuel filter cable, start-stop rocker switch mounted on set control
• Spin-on, full-flow oil filter Ignition system: Electronic magneto type with resistor plugs
• Low oil pressure protection Lubrication: Full pressure positive displacement lube
• Over/under speed protection oil pump, spin-on, full-flow lube oil filter, low oil pressure
• Low power factor field over current protection shutdown, dipstick
• Digital voltage regulation Cylinder crankcase: Alloy aluminum with iron cylinder
• Hydraulic pump standard on some models liners cast into the block, aluminum oil base
• 10 ft generator set output leads Cylinder head: Aluminum, OHV, removable
Alternator details
Design: Cummins Onan, revolving field, AC, 2-pole self- Excitation: Capped, digital voltage regulation
excited, two bearing design DC brushes: Electrographic; long life
Insulation system and temperature rise: Meets Bearing: Double-sealed pre-lubricated ball bearings
requirements of NEMA MG-1 and CSA C22.2, Std. 100
Generator set performance
Motors and Generators
Cooling: Direct drive centrifugal blower, cast aluminum Hydraulic pump
housing for excellent heat transfer • Fixed displacement gear pump, 1.5 Gal/min at 2500 psi
• A generator set with a hydraulic pump is rated with the
Rotor: Laminated electrical steel assembly press-fitted
pump idle
to shaft, balanced; heavy insulated copper wire windings;
• When using a non-Cummins Onan pump supplied by
optimized air gap for improved waveform and motor the customer, the hydraulic pump shaft seals must be
starting; Class 200 magnet wire capable of operating in a temperature environment of
Stator: Laminated electrical steel assembly, skewed for 225° F to 250° F. Seal failure will result in equipment
improved waveform; Class 200 quadrature wire with 70% damage
more insulation over comparable generator sets
Frequency regulation No load/Full load 1.7% Constant load 1.7%
Voltage regulation No load/Full load 2.0% Constant load 1.7%
Note: This outline drawing is provided for general reference only and is not intended for design or installation. For more information see
Operation and Installation manuals or obtain drawing 500-3449 and wiring diagram from your distributor/dealer.
! WARNING: ! WARNING:
Do not use this generator set on a Back feed to a utility system can
boat. Such use may violate U.S. cause electrocution and/or
Coast Guard regulations, and can property damage. Do not connect
result in severe personal injury or to any building electrical except
death from fire, explosion, through an approved device or
electrocution, or carbon after building main breaker is
monoxide poisoning. open.