You are on page 1/ 2

REF: FGD:AGITATORS

TECHNICAL SPECIFICATION OF
AGITATORS REV. No. 01

Annexure-IV MOTOR DATASHEET FOR AGITATORS ( TO BE FILLED FOR EACH AGITATOR)


Project :
Enquiry No :

SLNO Description DATA


A. GENERAL
1. Manufacturer & Country of origin.
2. Equipment driven by motor
3. Motor type
4. Quantity
B. DESIGN AND PERFORMANCE DATA
1. Frame size
2. Type of duty
Type of enclosure /Method of cooling/ Degree of
3.
protection
Applicable standard to which motor generally
4.
conforms
5. Efficiency class as per IS 12615(IE3)
6. (a)Whether motor is flame proof
(b)If yes, the gas group to which it conforms as per
IS:2148
7. Type of mounting
8. Direction of rotation as viewed from DE END
Standard continuous rating at 40 deg.C. Ambient
9.
temp. as per Indian Standard (KW)
Derated rating for specified normal condition i.e.
10.
50 deg. C ambient temperature (KW)
Maximum continuous load demand of driven
11.
equipment in KW
12. Rated Voltage (volts)
13. Permissible variation of :
a. Voltage (Volts)
b. Frequency (Hz)
c. Combined voltage and frequency
14. Rated speed at rated voltage and frequency(RPM)
15. At rated Voltage and frequency:
a. Full load current
b. No load current

Page 32 of 37
BIDDER SIGN WITH SEAL AND DATE:
REF: FGD:AGITATORS
TECHNICAL SPECIFICATION OF
AGITATORS REV. No. 01

16. Power Factor at


a. 100%/75%/50% load
b. NO load
c. Starting.
17. Efficiency at rated voltage and Frequency,
a.100% load
b. 75% load
c. 50% load
18. Starting current (amps) at
a. 100 % voltage
b. 85% voltage
c. 80% voltage
19. Minimum permissible starting Voltage (Volts)
Starting time with minimum
20.
permissible voltage/80%/ 100%/ 110%
a. Without driven equipment coupled
b. With driven equipment coupled
Safe stall time with 100% ,110% &
21.
80% of rated voltage
a. From hot condition
b. From cold condition
22. Torques :
a. Starting torque at min. permissible
voltage(kg-mtr.)/ rated voltage
b. Pull up torque at rated voltage.
c. Pull out torque
d. Min accelerating torque (kg.m) available at
lowest permissible starting voltage
e.Rated torque (kg.m)
Stator winding resistance per phase
23.
(ohms at 20 Deg.C.)
24. GD2 value of motors
No of permissible successive starts when motor is
25.
in hot condition
26. Locked Rotor KVA Input
27. Locked Rotor KVA/KW
28. Vibration limit :Velocity (mm/s)
29. Noise level limit (dBA)
C. CONSTRUCTIONAL FEATURES
1. Stator winding insulation

Page 33 of 37
BIDDER SIGN WITH SEAL AND DATE: