www

.S LAR GAUGE .com


Sales Office by 888-884-2843
888-884-4145 - Fax
20675 N. Friends Road
P. O. Box 309
GREENLEaF Outside USA
208-453-1714
Greenleaf, ID 83626
USA
GAUGE 208-459-3365 - Fax
A Division of I.T.M. Electronics, Inc.

EFG-8000 QUICK START GUIDE


DO NOT PROCEED WITHOUT UNDERSTANDING THE FOLLOWING:
You MUST: Ensure that the 2” NPT pipe nipple is vertically straight using a level. Adjust if needed.

Verify that the probe, transducer, and gauge that you received are a matched set.
If for any reason they are separated or used in an application other than that which
they were intended, re-programming will be required.

PROBE TRANSDUCER GAUGE

1. The gauge has been pre-programmed and put into a “SLEEP MODE” for storage and shipping to preserve power.
Sleep mode will constantly display the Program Version, i.e. 80-E. To wake up the gauge: Use the pocket magnet to
touch the PLANET symbol on the front of the gauge. Hold only until the gauge display changes to the Firmware
version, i.e. 11 - 00 or similar. Pull away the magnet and it will go to normal operating mode.

NIPPLE HEIGHT (4” minimum from top of primary to top of nipple)


1 TANK SHAPES
2” NPT Interstitial cavity
M Threads

2 3
4
4. TYPE OF LIQUID TO BE MEASURED.
SUCH AS GAS, DIESEL, ETC.
PRIMARY TANK HEIGHT
3 TOTAL DISTANCE
FROM TOP OF 5
OR SIDE WALL HEIGHT
NIPPLE TO THE 5. ACTUAL 100% CAPACITY OF TANK.
OF SINGLE WALL TANK
BOTTOM OF TANK

The probe for this tank was ordered and custom designed for use in a tank that measures see number 3 box, total
inches from the top of the 2” pipe nipple to the inside bottom of the primary tank. If the actual distance differs
from this amount, you will need to compensate. The chain can be shortened by choking it up to the desired
length, DO NOT CUT IT! Pass the extra beads through the connector and snap the correct bead closest to the
right adjustment into the connector. Follow the assembly instructions in the EFG-8000 USER’S Guide if needed.
Make sure the measurements match up by changing the length of the pipe nipple, or connecting to another bead
on the chain other than the end bead. The probe for this tank should be inches off the bottom of the tank.
THE PROBE MUST NEVER TOUCH THE BOTTOM OF THE TANK DURING NORMAL OPERATION
or EXTEND ABOVE THE PRIMARY TANK HEIGHT. SEE ORDER INFORMATION SHEET FOR
PLACEMENT.
REFER TO PAGE 11 OF ONLINE USERS GUIDE FOR TROUBLESHOOTING AND TECHNICAL ASSISTANCE.

03/20 © 2020 Greenleaf Gauge Page 1


EFG-8000
QUICK START GUIDE
INSTALLATION:
The EFG-8000 must be installed in accordance with your local regulations and manufacturer’s specifications.
Failure to do so may affect the long term service of the gauge and may void the warranty. Any regulatory issues
should be directed to your local entity having jurisdiction over the issues involved. Manufacturer’s specifications
require any wire connections to the transducer, gauge, and their connectors, to be protected from the elements
and other possible physical damages, by the use of appropriate electrical items such as conduit and junction
boxes. The manufacturer will not be responsible for problems arising from improper equipment installation
which may also void the warranty. Please refer to assembly instructions, page 3 of the online User’s Guide.
IMPORTANT NOTICE: When this gauge and alarm are utilized as the High-level warning, the test/reset button
should ALWAYS be tested, before filling the tank, by the operator by pressing and holding the button . If it does not
respond correctly DO NOT FILL. The operator must monitor the tank filling process and the status of the gauge
and alarm to prevent overfills. When tank is empty at installation the gauge will never read zero. It will read the
gallons that are between the bottom of the probe and the bottom of the tank.
THE ONLINE USER GUIDE INCLUDES THE FOLLOWING INFORMATION.
Assembly/Installation.........................page 3 Determining Total Gallons.........................page 11
Programming Details...........................page 4 Specifications.............................................page 12
Using Calibration Weights...................page 5-10 Repair and Return Policies........................page 12
Other Calibration Issues......................page 10 Manufacturer Suggested Annual
Troubleshooting..................................page 11 Maintenance Protocols......................page 13-16
Information needed for a tech call.......page 11 Warranty......................................................page 17

Trans + (Red wire)


Trans S (White Wire)
Trans - (Black Wire)
Interstitial (Black)
Interstitial (Black)
No Connection
Data Gnd -
To your Data Out +
SCADA
or
Controller OR

Primary Tank

OR

Interstital Cavity

HELP: Voice: 208-453-1714 Voice: 1-888-884-2843 Email: [email protected]


Fax: 208-459-3365 Fax: 1-888-884-4145
Web site: www.solargauge.com
3/20 © 2020 Greenleaf Gauge Page 2