0% found this document useful (0 votes)
13 views

85010-0089_Product_Data_Sheet

The SIGA-AA30 and SIGA-AA50 are high-efficiency audio amplifiers designed for life safety systems, offering 30 and 50 watts of output, respectively. They feature dual input channels, backup amplification capabilities, and a built-in 1kHz tone generator for emergencies. These amplifiers are suitable for distributed audio applications and can be configured for either 25Vrms or 70Vrms output.

Uploaded by

Alaa M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
13 views

85010-0089_Product_Data_Sheet

The SIGA-AA30 and SIGA-AA50 are high-efficiency audio amplifiers designed for life safety systems, offering 30 and 50 watts of output, respectively. They feature dual input channels, backup amplification capabilities, and a built-in 1kHz tone generator for emergencies. These amplifiers are suitable for distributed audio applications and can be configured for either 25Vrms or 70Vrms output.

Uploaded by

Alaa M
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

EST Catalog u EST2 Mid-Range Life Safety Systems

Intelligent Audio
Amplifiers
SIGA-AA30, SIGA-AA50

Overview Standard Features


SIGA amplifiers are high efficiency switch mode audio amplifiers • Remote or Local mounting
available in 30 and 50 watt sizes. Amplifiers have two input chan-
• Two channel input
nels supporting dual channel or single channel audio applications.
Amplifier project application flexibility is enhanced by provision for • Connects to signature data circuit. Allows switching between
input levels at 1Vrms or 25Vrms. This allows SIGA amplifiers to two channels without additional control modules. Eliminates the
obtain their input from a line level signal or the output of another need for additional amplifier monitoring.
25Vrms amplifier. This feature provides great application flexibil- • Output selectable as 25Vrms or 70Vrms
ity helping meet project requirements. Input channel selection is
made through system software programming transmitted to the • Dual input level allows the use of a 1Volt or 25Volt input signal.
amplifier via a Signature data circuit. This reduces wiring intercon- • Back up amplifier connection
nect requirements by reducing the number of control modules
needed. • Back up 1kHz tone generator

Each amplifier has provision for connecting back up amplification.


Amplifiers can be backed up one-to-one or multiple amplifiers can Application
have one shared back up amplifier. In addition to back up amplifi-
Signature amplifiers are ideally suited for distributed audio applica-
ers each SIGA amplifier has an on board 1kHz tone generator that
tions and small centrally banked applications. The audio output
can activate in the event of input failure or if no back up amplifier is
is configurable as 25Vrms or 70Vrms in Class B or Class A wiring
available.
configurations. Speakers can connect directly to the output of the
amplifier or the amplifier output can run as a audio riser to signa-
ture modules where speaker zone selection is made. Each ampli-
fier has a built in 1kHz tone generator and provision for a back up
amplifier. Should an amplifier lose its input signal the output will
switch to a back up amplifier. If there is no back up amplifier or
the output from the back up is unavailable the output will receive
the internal 1kHz tone as the evacuation signal. On board status
LEDs provide quick visual indication of amplifier status including,
Power Amp. Enabled, Backup Mode, Amplifier Active, and Normal
Communications.

Page 1 of 2 D ATA S H E E T 85010-0089


Not to be used for installation purposes. Issue 3
1
To Next Amp Shield Optional
Channel 1 Input Status LEDs 2
Audio Output
to Speakers or 47K

Engineering Specification
From Channel 1
Signal Source
1Vrms or 25Vrms
1
AA30, AA50 Status LEDs Signature device
Output Return
EO

Class A Only
Amplifier
System remote amplifiers must communicate their status directly to the main control
2

25V
70V
From Output of
From Channel 2 1
Backup Amp
panel. ExternalSignal
1Vmonitoring
Source
rms or 25Vrms
is not acceptable. Each amplifier must support dual channel JP2

audio. Amplifiers must support input signals at line a built in back up 1kHz tone generator
2
1
To Backup Input
To Next Amp of Next Amp
that automatically activates with loss of input signal. Each amplifierSelection
mustJumper haveToprovision
Output Voltage
Channel 2 Input
24 VDC
for a back up amplifier.
Signature DeviceIt must be possible to
From Previous
default
To Next
Signature Device to back up tone or standby amplifier

in the event of the loss of input signals.


1 Twisted-Shielded Pair Wire

Detection & alarm since 1872


Typical Wiring
2 One Twisted Pair Wire, Shield optional

U.S. 1
Shield Optional
To Next Amp
T 888-378-2329 Channel 1 Input Status LEDs 2
Audio Output
F 866-503-3996 to Speakers or 47KW

Canada
From Channel 1
Signal Source
1Vrms or 25Vrms
1 Status LEDs
AA30, AA50 Signature device
Output Return
EOL

Class A Only
Chubb Edwards Amplifier 2

25V
70V
From Output of
T 519 376 2430 From Channel 2 1
Backup Amp
Signal Source
F 519 376 7258
JP2
1Vrms or 25Vrms
2
1
To Backup Input
Southeast Asia To Next Amp
Channel 2 Input
Output Voltage of Next Amp
Selection Jumper
T : +65 6391 9300 From Previous To Next
To 24 VDC

F : +65 6391 9306 Signature Device Signature Device

India 1 Twisted-Shielded Pair Wire


T : +91 80 4344 2000
F : +91 80 4344 2050 Specifications 2 One Twisted Pair Wire, Shield optional

Australia
Catalog Number SIGA-AA30 SIGA-AA50
T +61 3 9239 1200 Active Power Required 1700 mA @ 24 Vdc 3200 mA @ 24 Vdc
F +61 3 9239 1299 Audio Power Output 30 Watts @ 25Vrms or 70Vrms 50 Watts @ 25Vrms or 70Vrms
Primary Inputs Dual inputs, each 1Vrms
Europe Standby Power Required 1mA @ 24 Vdc
T +32 2 725 11 20 Agency Listings UL
F +32 2 721 86 13
Frequency Response 800Hz to 2.8kHz (ULI) 400 Hz to 4 kHz (ULC), at -3db
Latin America Harmonic Distortion <5%
T 305 593 4301 Signature Data Circuit 2 module addresses
F 305 593 4300 Terminal Wire Gauge 18-12 AWG (0.75-2.5 mm²)
Mounting One space in RACCR, 2-WB3 or 2-WB7
utcfireandsecurity.com Relative Humidity 10-93% non condensing
Temperature Rating 0°-49°C (32° - 120°F)
© 2010 UTC Fire & Security.
All rights reserved.
Back up tone 1kHz
Wiring Styles Class A or Class B Output

Ordering Information
Catalog Ship Wt.
Description
Number lb. (kg)
SIGA-AA30 30 Watt Intelligent Audio Amplifier 2 (.9)
SIGA-AA50 50 Watt Intelligent Audio Amplifier 2 (.9)
SIGA-AA30-CS 30 Watt Intelligent Audio Amplifier (for connection to 25Vrms inputs) 2 (.9)
SIGA-AA50-CS 50 Watt Intelligent Audio Amplifier (for connection to 25Vrms inputs) 2 (.9)
Wallboxes
EST2 Long Surface Wallbox (order 2-WB3D door separately) - Gray
2-WB3 38 (17.3)
finish. For Semi-Flush mounting order Trim Kit. See note 1
EST2 Double Wide Surface Wallbox (order 2-WB7D door separately)
2-WB7 75 (34)
- Gray finish. For Semi-Flush mounting order Trim Kit. See note 1
Remote Audio Closet Cabinet (order RACCDR door separately). Red
RACCR 32 (14.5)
Finish
Trim Kits
2-LFK Long Semi-Flush Trim Kit for 2-WB3 wallbox. See note 1 4 (1.8)
2-DFK Double Wide Semi-Flush Trim Kit for 2-WB7 box. See note 1 5 (2.3)
Note 1: Standard finish is gray, red versions are available by adding suffix R to the catalog number e.g. 2-WB3R
Related Equipment
SIGA-APS 6.4 Amp Power Supply 2 (.9)
SIGA-APS-220 6.4 Amp Power Supply 220 Vac 2 (.9)
05-18-11

Page 2 of 2 D ATA S H E E T 85010-0089


Not to be used for installation purposes. Issue 3