0% found this document useful (0 votes)
6 views

rcdc foundation report

The document outlines footing design calculations for a project, detailing parameters, code references, and design specifications. It includes analysis of soil pressure, uplift conditions, sliding, and overturning checks, along with reinforcement requirements. The calculations are based on IS 456 and BS 8007 standards, using specific material grades and dimensions for the footing design.

Uploaded by

Sayan Dutta Bar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
6 views

rcdc foundation report

The document outlines footing design calculations for a project, detailing parameters, code references, and design specifications. It includes analysis of soil pressure, uplift conditions, sliding, and overturning checks, along with reinforcement requirements. The calculations are based on IS 456 and BS 8007 standards, using specific material grades and dimensions for the footing design.

Uploaded by

Sayan Dutta Bar
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

Page 1 of 11

FOOTING DESIGN CALCULATIONS


Project Name : Unassigned
Client Name : Unassigned
Engineer Name : Unassigned
Design File : D:\Deyan\189. PLATFORM SIDING SHED\STAAD R3\New
folder\STAAD BY SOHOM\platform siding shed 29.01.25-Footing-
1.rcdx
Analysis File : D:\Deyan\189. PLATFORM SIDING SHED\STAAD R3\New
folder\STAAD BY SOHOM\platform siding shed 29.01.25.STD
Analysis Last Modified : 2/5/2025 6:11:31 PM

Definitions:
1. α = Coefficient of Thermal Expansion
2. ε1 = Strain at level considered, Calculated ignoring the
stiffening of the concrete in tension zone
3. εm = Average steel strain at level considered
4. ρact = Percentage steel provided
5. ρcrit = Percentage steel critical as per code
6. A = Plan area of footing base
7. Acr = Distance from the point considered to the surface of the
nearest longitudinal bar
8. AstPrv = Area of tensile reinforcement provided
9. Astrqd = Area of tensile reinforcement required
10. Asv = Area of shear reinforcement required
11. AsvPrv = Area of shear reinforcement provided
12. A1 = Bearing area of footing at slope of 1:2
13. A2 = C/s Area of column
14. B = Width of footing base
15. Beff = Effective width of footing
16. BoffB = Footing offset along B below column in plan
17. BoffT = Footing offset along B above column in plan
18. B1 = Width of sloped footing at top
19. ColOff = Column offset in sloped footing
20. D = Depth of footing
21. Deff = Effective Depth of footing
22. Df = Depth of founding layer
23. Dw = Ground water level
24. Ec = Modulus of elasticity of concrete
25. Es = Modulus of elasticity of steel
26. Foss = Safety factor against sliding
27. Fosu = Safety factor against uplift
28. Fst = Stress in steel
29. L = Length of footing base

2/6/2025
Page 2 of 11

30. Leff = Effective length of footing


31. LoffL = Footing offset along L on left side of column
32. LoffR = Footing offset along L on right side of column
33. L1 = Length of sloped footing at top
34. Mx = Bending Moment along column D
35. Mx' = Bending Moment along column D due to odd shaped
column
36. Mex = Eccentricity moment along column D
37. Mxx = Total Bending Moment along column D (Mx + Mx' + Mex)
38. My = Bending Moment along column B
39. My' = Bending Moment along column B due to odd shaped
column
40. Mey = Eccentricity moment along column B
41. Myy = Total Bending Moment along column B (My + My' + Mey)
42. Muy = Factored moment along column B
43. Muy' = Factored Moment along column B due to odd shaped
column
44. Mux = Factored moment along column D
45. Mux' = Factored Moment along column D due to odd shaped
column
46. Netdown = Net downward load
47. OB = Maximum permissible offset on bottom side of column in
plan
48. OL = Maximum permissible offset on left side of column in plan
49. OR = Maximum permissible offset on right side of column in
plan
50. OT = Maximum permissible offset on top side of column in plan
51. P = Axial load for footing sizing
52. P1 = Soil pressure at corner 1
53. P2 = Soil pressure at corner 2
54. P3 = Soil pressure at corner 3
55. P4 = Soil pressure at corner 4
56. Pdelta = Column Load to be transferred by reinforcement
57. Pt = Calculated percentage tensile reinforcement
58. Pu = Factored axial load
59. q = Surcharge Load
60. sp = Spacing Between bars at outer most layer
61. SPu = Upward Soil Pressure
62. SPuL = Upward Soil Pressure from left
63. SPuR = Upward Soil Pressure from right
64. SPuB = Upward Soil Pressure from bottom
65. SPuT = Upward Soil Pressure from top
66. Tc = Design shear strength of concrete
67. Temp1 = Peak Hydration temperature

2/6/2025
Page 3 of 11

68. Temp2 = Seasonal Temperature Variations


69. Tv = Nominal shear stress
70. Vu = Design shear force
71. Vus = Strength of shear reinforcement
72. Vx = Shear along major axis
73. Vy = Shear along minor axis
74. Waterpr = Upward water pressure
75. Waterup = Upward force due to water
76. Wcr = Surface Crack Width
77. WFoot = Add. Wt. due to difference in concrete and soil density
78. WFootc = Weight of footing and column with concrete density
79. WSoil = Weight of soil covering footing area
80. Zx = Section modulus of footing base along L
81. Zy = Section modulus of footing base along B

Code References:
IS 456
Parameter Reference
1. Ptmax : Cl. 26.5.2.1
2. Ptmin : Cl. 26.5.2.1
3. Pt : Cl. 38
4. Tc : Cl. 40.2.1
5. Tcmax : Cl. 40.2.3
6. Asv : Cl. 40.4
7. Min Shear Reinf : Cl. 26.5.1.6
8. Max Stirrup Spacing : Cl. 26.5.1.5
9. Punching Shear design : Cl. 31.6.3
10. Load transfer : Cl. 34.4
11. Ptnominal : Cl. 34.5.2
12. Crack width calculation : Annex-F
13. Cracking : Cl. 35.3.2

BS 8007 (For Early / Initial Thermal Cracking)


1. Surface Zone for suspended : Figure A.1
slab
2. Surface Zone for ground slab : Figure A.2
3. Factors for the calculation of : Table A.1
minimum reinforcement

Design Code : IS 456 : 2000 + IS 13920 : 2016


Footing No : FC11
Column No : C11 ( 590 mm X 1290 mm)

2/6/2025
Page 4 of 11

Analysis No : 9555

Concrete Grade : M30 N/sqmm


Steel Grade : Fe550 N/sqmm
Clear Cover : 50 mm
Df : 3M
Dw : 1.6 M

Density of Soil = 18 kN/cum


Soil Bearing Capacity = 150 kN/sqm
Permissible SBC Increase for EQ = 25 %
Permissible SBC Increase for Wind = 25 %
Live Load Reduction = 50 %
Permissible area of loss of contact = 5 %

Design cross section by : Average pressure


Consider overburden pressure

Footing Type : Pad


Footing Size (L x B x D) : 5300mm X 4600mm X 300mm
Without considering Effect of Water
Table
Footing Self Wt., F1 = 182.85 kN
Soil Weight, S1 = 1147.88 kN
Total Weight, W1 = F1 + S1
= 1330.73 kN
Considering Effect of Water Table
Footing Self Wt., F2 = 109.71 kN
Soil Weight, S2 = 888.07 kN
Weight of Water (Submerged column),
= 8.37 kN
Wc
Total Weight, W2 = F2 + S2 - Wc
= 989.41 kN
Offset Along L (Loff) = 2005 mm
Offset Along B (Boff) = 2005 mm

Check For Maximum Soil Pressure:


Critical Analysis Load Combination = 200
Critical Load Combination = [33] : (LOAD 3: DL) +(LOAD 4: LL) +(LOAD
9: CL)
Pcomb = 732.36 kN
P = Pcomb + W1
P = 2063.09 kN

2/6/2025
Page 5 of 11

Mx = -857.88 kNm
My = 0.67 kNm
P/A = 84.62 kN/sqm
Mx/Zx = -39.84 kN/sqm
My/Zy = 0.04 kN/sqm
Maximum Soil Pressure = 124.49 kN/sqm
Allowable Soil Pressure = 1x150 kN/sqm
= 150 kN/sqm

Check For Minimum Soil Pressure:


Footing designed with loss of contact
Critical Analysis Load Combination = 213
Critical Load Combination = [46] : (LOAD 3: DL) +(LOAD 5: WLX)
Pcomb = 215.27 kN
P = Pcomb + W2
P = 1204.68 kN
Mx = 1144.06 kNm
My = 2.84 kNm
P/A = 63.41 kN/sqm
Mx/Zx = 53.12 kN/sqm
My/Zy = 0.15 kN/sqm
Minimum Soil Pressure = -3.86 kN/sqm
< 0
Uplift condition = Short edge uplift
Area of loss of contact = 0.91558 sqm
= 3.755 %
< 5 %
Corner pressure P1 = -3.849 kN/sqm
Corner pressure P2 = 102.839 kN/sqm
Corner pressure P3 = 102.523 kN/sqm
Corner pressure P4 = -4.165 kN/sqm
Distance measured from uplift
Point of zero pressure
corner
Along long edge 1 = 0.21 m
Along long edge 2 = 0.19 m

Check For Buoyancy:


Critical Analysis Load Combination = 214
Critical Load Combination = [47] : (LOAD 3: DL) +(LOAD 6: WLZ)
Pcomb = 32.01 kN
Factor of safety = 1.4
Depth of Founding Layer = 3 m
Ground Water Level = 1.6 m

2/6/2025
Page 6 of 11

Water Pressure = 14 kN/sqm

Upward force = Water Pressure X L X B


= 341 kN
Downward force = Pcomb + (F2 + S2 - Wc)
= 1021.42 kN
Downward Force /
Factor of safety available =
Upward Force
= 2.99
> 1.4
Check For Sliding:
Critical Analysis Load Combination = 213
Critical Load Combination = [46] : (LOAD 3: DL) +(LOAD 5: WLX)
Coefficient Of Friction = 0.5
Factor of safety = 1.2
Pcomb = 215.27
Shear Vx = 0.95 kN
shear Vy = 149.02 kN
Resultant sliding force = 149.03 kN
Downward force = Pcomb + (F2 + S2 - Wc)
= 1204.68 kN
Upward water pressure = 341.32 kN
Net downward force = 863.36 kN
Friction Coeff X Net
Force resisting sliding =
Downward Force
= 431.68 kN
Resisting Force / Sliding
Factor of safety available =
Force
= 2.90
> 1.2

Check For Overturning:


Along Width:
Critical Analysis Load Combination = 213
Critical Load Combination = (LOAD 3: DL) +(LOAD 5: WLX)
Factor of safety = 1.50
Pcomb = 215.27 kN
Moment Mx = 1144.06 kNm
P = Pcomb + (F2 + S2 - Wc)
= 1204.68 kN
Stabilizing Moment for P = 3192.41 kNm
DeStabilizing Moment = 1144.06 kNm
Overturning Factor of safety = 2.79

2/6/2025
Page 7 of 11

Safe in Overturning > 1.50

Along Length:
Critical Analysis Load Combination = 212
Critical Load Combination = (LOAD 3: DL) -(LOAD 2: SLZ)
Factor of safety = 1.50
Pcomb = 137.71 kN
Moment My = 51.54 kNm
P = Pcomb + (F2 + S2 - Wc)
= 1127.12 kN
Stabilizing Moment for P = 2592.37 kNm
DeStabilizing Moment = 51.54 kNm
Overturning Factor of safety = 50.3
Safe in Overturning > 1.50

Design For Bending:


Bottom Reinforcement Along L:
Critical Analysis Load Combination = 200
Critical Load Combination = [82] : (LOAD 3: DL) +(LOAD 4: LL) +(LOAD
9: CL)
Pu = 732.36 kN
Mux = -857.88 kNm
Muy = 0.67 kNm
P/A = 30.04 kN/sqm
Mx/Zx = -39.84 kN/sqm
My/Zy = 0.04 kN/sqm

Deff = 242 mm
Beff = 4600 mm
SPu = 69.87 kN/sqm
Mu = SPu X B X Loff X Loff / 2
= 646.07 kNm
Pt = 0.559 %
Ast Rqd (BM) = 6220 sqmm
Ast Prv (Distributed Across Total Width) = 31 - T16 @ 155
= 6233 sqmm

Top Reinforcement Along L:


Percentage loss of contact (LOC) = 3.755 %
Weight of footing per unit area (W1) = D X Concrete Density
= 7.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen

2/6/2025
Page 8 of 11

= 48.6 kN/sqm
Total downward weigth per unit area
= W1 + W2
(W)
= 56.1 kN/sqm
Component of footing length subjected
= (LOC / 100) X L
to LOC (LOCL)
= 199.015 mm
Moment along L = W X (LOCL^2) X B / 2
= 5.11 kNm
Effective width = B
= 4600 mm
Pt = 0.07 %
Ast Calculated = 828 sqmm
Ast Provided = 17 - T12 @ 300 c/c
= 1923 sqmm
Bottom Reinforcement Along B:
Critical Analysis Load Combination = 202
Critical Load Combination = [84] : (LOAD 3: DL) +0.8 (LOAD 4: LL) +0.8
(LOAD 2: SLZ) +0.8 (LOAD 9: CL)
Pu = 735.49 kN
Mux = -725.82 kNm
Muy = 43.51 kNm
P/A = 30.17 kN/sqm
Mx/Zx = -33.7 kN/sqm
My/Zy = 2.33 kN/sqm

Deff = 226 mm
Leff = 5300 mm
SPu = 32.5 kN/sqm
Mu = SPu X L X Boff X Boff / 2
= 346.18 kNm
Pt = 0.282 %
Ast Rqd (BM) = 3377 sqmm
Ast Prv (Distributed Across Total
= 30 - T12 @ 185
Length)
= 3393 sqmm

Top Reinforcement Along B:


Percentage loss of contact (LOC) = 3.755 %
Weight of footing per unit area (W1) = D X ConDen
= 7.5 kN/sqm
Weight of soil over footing (W2) = (Df - D) X SoilDen
= 48.6 kN/sqm

2/6/2025
Page 9 of 11

Total downward weigth per unit area


= W1 + W2
(W)
= 56.1 kN/sqm
Component of footing breadth subjected
= (LOC / 100) X B
to LOC (LOCB)
= 172.73 mm
Moment along B = W X (LOCB^2) X L / 2
= 4.436 kNm
Effective width = L
= 5300 mm
Pt = 0.08 %
Ast Calculated = 954 sqmm
Ast Provided = 19 - T12 @ 300 c/c
= 2149 sqmm

Design For Shear:


One Way Shear Along L:
Critical Section @ d from Column Face
= 242 mm
Critical Analysis Load Combination = 200
Critical Load Combination = [82] : (LOAD 3: DL) +(LOAD 4: LL) +(LOAD
9: CL)
Pu = 732.36 kN
Mux = -857.88 kNm
Muy = 0.67 kNm
P/A = 30.04 kN/sqm
Mx/Zx = -39.84 kN/sqm
My/Zy = 0.04 kN/sqm

Deff = 242 mm
Beff = 4600 mm
SPu = 69.87 kN/sqm
Vu = SPu X (Loff - d) X B
= 566.67 kN
Tv = Vu / (Beff X Deff)
= 0.51 N/sqmm
Tc = 0.52 N/sqmm
Tv < Tc

One Way Shear Along B:


Critical Section @ d from Column Face

= 226 mm
Critical Analysis Load Combination = 202

2/6/2025
Page 10 of 11

Critical Load Combination = [84] : (LOAD 3: DL) +0.8


(LOAD 4: LL) +0.8 (LOAD
2: SLZ) +0.8 (LOAD 9: CL)
Pu = 735.49 kN
Mux = -725.82 kNm
Muy = 43.51 kNm
P/A = 30.17 kN/sqm
Mx/Zx = -33.7 kN/sqm
My/Zy = 2.33 kN/sqm

Deff = 226 mm
Leff = 5300 mm
SPu = 32.5 kN/sqm
Vu = SPu X (Boff - d) X L
= 306.39 kN
Tv = Vu / (Leff X Deff)
= 0.26 N/sqmm
Tc = 0.39 N/sqmm
Tv < Tc

Design For Punching Shear:


Critical Section @ d/2 from Column Face
= 117 mm

Critical Analysis Load Combination = 202


Critical Load Combination = [84] : (LOAD 3: DL) +0.8 (LOAD 4: LL) +0.8
(LOAD 2: SLZ) +0.8 (LOAD 9: CL)
Pu = 735.49 kN
Mux = -725.82 kNm
Muy = 43.51 kNm
P/A = 30.17 kN/sqm
Mx/Zx = -33.7 kN/sqm
My/Zy = 2.33 kN/sqm

Deff = 234 mm
Leff = 1524 mm
Beff = 824 mm
Punching Perimeter = 4696 mm
Punching Area = 1098864 sqmm
SPu = Average Pressure
= 30.17 kN/sqm
Vu = SPu X ((L X B)-(Leff X Beff))
= 697.61 kN
Tv = Vu / Punching Area

2/6/2025
Page 11 of 11

= 0.635 N/sqmm
Tc = 1.311 N/sqmm
Tv < Tc

Load Transfer Check For Load Transfer From Column To Footing


Critical Analysis Load Combination = 202
Critical Load Combination = [84] : (LOAD 3: DL) +0.8
(LOAD 4: LL) +0.8 (LOAD
2: SLZ) +0.8 (LOAD 9: CL)
Pu = 735.49 kN
A2 = 0.76 sqm
A1 = 4.46 sqm
Base Area = 24.38 sqm
A1 < Base Area
Modification Factor = SquareRoot(A1/A2) < = 2
SquareRoot(A1/A2) = 2.4225
Thus, Modification Factor = 2
Concrete Bearing Capacity = 0.45 X Fck X Modification Factor X Column
Area
= 20549.7 kN
Concrete Bearing Capacity > Pu, Hence Safe.