Spektrum-SmartLink-ESC-UpdateandProgram
Spektrum-SmartLink-ESC-UpdateandProgram
GENERAL SETTINGS
• Flight Mode
o Fixed Wing (*)Default – For use with Aircraft and non-governed Heli models
o Helicopter – Enables the Speed governing “Govenor” mode for fixed RPM motor speeds
• Brake Type
o Disabled (*) Default – Motor will free wheel when throttle position is zero
o Normal – When throttle position is zero, the assigned brake force will be applied
o Proportional - With this option selected the throttle range changes so the ESC will not
start below 20%. The throttle will operate as normal above 20%, but moving the throttle
below 20% will apply the brakes, increasing in strength as the signal drops to 0%.
THROTTLE – CONTROL
• BEC Voltage - Select the BEC output voltage. Default and available settings per ESC.
• Start-up Mode
o Normal Start-up: If this mode is selected, the motor will immediately increase in RPM to
correspond to the throttle stick input.
o Soft Start-up: If this mode is selected, the motor will gradually increase in RPM to
correspond to the throttle stick input.
TIP: We recommend using this soft start-up mode when using large diameter motors or
gear drives.
• Timing - Select Low, Medium, or High motor timing.
• Motor Rotation - Adjust the rotation direction of the motor without changing wires.
• Active Freewheeling - This option can be set to Enabled or Disabled. Freewheeling can help provide
better throttle linearity or smoother throttle response.
• Thrust Rev – Use this option to select the channel used to activate motor reversing. Reverse must
set in the Brake Type menu
• Governor Gain (Heli Mode only) - Controls how aggressively the governor maintains the set RPM -
Level 1 (less) to Level 3 (more)
• Auto Restart Time (Heli Mode only) - Set the auto-rotation bailout timing
• Restart Accel (Heli Mode only) - Controls how aggressively RPMs are recovered when performing
Auto-rotation bailout
GOVERNOR SETUP
If the governor mode is activated, the ESC will try its best to hold the rotor head speed at a fixed value
that you assign. In order for your Avian ESC to calculate the speed of the main rotor blades of your
helicopter, you need to know the motor
poles number and the gear ratio of main
drive gear vs. the pinion. Below is an
example of this screen with an Avian 100
setup for a Blade Fusion 480 model running
a 14 pole motor, 11 tooth pinion and 112
tooth main gear.
o Auto (Low) - Low cutoff voltage, not very easy to get the LVC Protection activated, is
applicable to batteries with poor discharge capability.
o Auto (Intermediate) - Medium cutoff voltage, prone to getting the LVC Protection
activated, is applicable to batteries with ordinary discharge capability.
o Auto (High) - High cutoff voltage, very prone to getting the LVC Protection activated, is
applicable to packs with great discharge capability.
ADVANCED
• Reverse Force – Select between 25% and 50%. 25% is the default.
• Start Mode (Punch) –
You can adjust the throttle punch from level 1 (very soft) to level 5 (very aggressive) as per the track,
tires, grip, your preference etc. This feature is very useful for preventing tires from slipping during the
starting-up process. In addition, “level 4” and “level 5” have strict requirement on battery’s discharge
capability. It may affect the starting-up if the battery discharges poorly and cannot provide large current
in a short time. The car stutters/cogs or suddenly loses power in the starting-up process indicating the
battery’s discharge capability is not adequate. Upgrade to higher C rating battery or you can reduce the
punch or increase the FDR (Final Drive Ratio) to help.
• Timing Mode - 0°/ 3.75° / 7.5° / 11.25° / *15° / 18.75° / 22.5° / 26.25°, default is 15°.
Usually, low timing value is suitable for most motors. But there are many differences among structures
and parameters of different motors so please try and select the most suitable timing value according to
the motor you are just using. The correct timing value makes the motor run smoothly. And generally,
higher timing value brings out higher output power and higher speed/rpm. Note: After changing the
timing setting, please test your RC model on ground prior to flight. Monitor for cogging, stuttering and
excessive motor heat, if these symptoms occur, reduce timing.
FIRMWARE UPGRADE
Updating you Spektrum Smart ESC is easy. Simply download the latest version of the SmartLink app, go
to the Firmware Upgrade Tab and click Upgrade. New ESC and Smart Technology features will be added
in the future for applicable Smart ESCs. When that occurs a new SmartLink App version will be available.
Note: When a Firmware upgrade is performed, all settings on your Smart ESC will return to the
defaults, please confirm the proper settings for your model before use.
o Select the top version from the “Available Versions” drop down box then click the “Upgrade” button
to perform the update
o Once the Upgrade button has been selected to install the update on your Smart ESC, a progress bar
will appear on your computer screen. Please allow the update to finish then click OK to save the
settings. You can disconnect and use your Smart ESC with the improved firmware now.
Change Log
August 20th 2021 – Available on Smartlink App V1.09
• Improved TextGen Programming Intialization – Throttle input will cancel Text gen entry sequence
and allows esc to function as normal
• Fixed Hand-Shake bug with latest Smart Receivers
• Added: Smart ESC Programming Via TextGen (May require transmitter update)
o Change Avian programmable settings via Spektrum DX \ iX \ NX transmitter and Smart receiver
▪ See more about Smart ESC Prog./TextGen in the explanation section near the end of this
document
• Improved: Motor compatibility
• Added: Each of the following adjustable parameters:
o Reverse brake type (item #2)
o Added “Surge” LVC option (item #4)
o Governor gain set up (item #12)
o Auto restart time (item #13)
o Restart acceleration time (item 14)
o Thrust reverse channel (item #15)
• Changed: Each of the following programmed defaults:
o Cutoff voltage from 3.2V/Cell to 3.4V/Cell (item #6)
o Active FreeWheel from Enabled to Disabled (item #11)
Change Log
August 20th 2021 – Available on Smartlink App V1.09
• Improved TextGen Programming Initialization – Throttle input will cancel Text gen entry sequence
and allows esc to function as normal
• Firma 60 Sensored Crawler – Changed default Reverse force to 100%
• Firma 60 Sensored Crawler – Added “Auto” Option 10 for Drag Brake Rate
o Automatically applies increased Drag Brake in ratio to motor speed (faster = less DB)
• Firma 100 and 120 – Removed 7.4v BEC Option for better RTR Servo Compatibility
• Firma 130 – Changed Default Settings
• Added: Firma Smart ESC Programming via TextGen (May require transmitter update)
o Change Firma programmable settings via Spektrum DX Surface transmitter and Smart receiver
▪ See more about Smart ESC Prog./TextGen in the explanation section near the end of this
document
Continue to the next page to see updated programming tables for all Avian and Firma Smart ESCs
and descriptions of the firmware changes
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 2.8V / Cell 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 3 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
3. Brake Force 0 1 2 4 5 6 7
6. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell 3.6V / Cell 3.8V / Cell
Programming Charts
Firma 60 Amp Sensored 1/10th Crawler Smart ESC
SPMXSE1060 Hardware Version:
Software Version: B01-00.0.19 and Programmer Version: V1.09 (Requires V2 SPMXCA200)
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8 Option 9 Option 10
1. Running Mode Forward / Reverse Forward / Reverse / Brake
2. Cutoff Voltage Disabled 3.0V / Cell 3.2V / Cell 3.4V / Cell
3. RPM/Throttle Matching Low Medium High
4. Max. Forward Force 25.0% 37.5% 50.0% 62.5% 75.0% 87.5% 100.0%
5. Max. Reverse Force 25.0% 37.5% 50.0% 62.5% 75.0% 87.5% 100.0%
6. Turbo Timing 0 deg to 10 deg Adjustable in 1 deg Increments (Default: 0 deg)
7. Turbo Delay Off, 0.0S 0.1s 0.2s 0.3s 0.4s 0.5s
8. Drag Brake Force 50% to 200% Adjustable in 5% Increments (Default: 80%)
9. Drag Brake Rate Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9 Auto
10. Neutral Range 6% to 17% Adjustable in 1% Increments (Default: 10%)
11. Starte Mode (Punch) Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9
12. BEC Voltage 6.0V 7.4V
12. Motor Rotation CW CCW
6. BEC 6.0V
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
6. BEC 6.0V
6. BEC 6.0V
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8 Option 9
1. Running Mode Forward & Brake Forward, Reverse & Brake Forward & Reverse
2. Drag Brake 0% 5% 10% 20% 40% 60% 80% 100%
3. Cutoff Voltage None 2.6V/Cell 2.8V/Cell 3.0V/Cell 3.2V/Cell 3.4V/Cell
4. Punch Level 1 Level 2 Level 3 Level 4 Level 5 Level 6 Level 7 Level 8 Level 9
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8 Option 9
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
Programmable Item Option 1 Option 2 Option 3 Option 4 Option 5 Option 6 Option 7 Option 8
5. Max Brake Force 25.0% 37.5% 50.0% 62.5% 75.0% 87.5% 100.0% Disabled