CWL TLC VH2 + V2C Control Panel Tables 06.04.24
CWL TLC VH2 + V2C Control Panel Tables 06.04.24
ExtCct.G
ExtCct.A
ExtCct.C
ExtCct.D
ExtCct.H
Cct. 11*
ExtCct.B
ExtCct.E
ExtCct.F
ExtCct.J
ExtCct.I
Cct. 10
Cct. 6*
Cct. 1
Cct. 2
Cct. 3
Cct. 4
Cct. 5
Cct. 7
Cct. 8
Cct. 9
Circuits Control type Button Function
Welcome Scene RCU - - - - - - - - - - 100% 0% 0% 100% 60% - - 100% 40% 100% - n/a n/a
BMS TIMER - 100% - - 100% 100% 100% 100% 100% 100% - - - - - - - - - - - n/a n/a
Control Panel 1 BUTTON
Front Porch 100% - - - - - - - - - - - - - - - - - - - - 1way 1 gang on/off
- - - - - - - - - - - - - - - - 0% 0% 0% 0% -
night light - - - - - - - -
recheck
- - - - - - - - - - - - 100% on/off
Cct. 20*
Cct. 12
Cct. 13
Cct. 14
Cct. 15
Cct. 16
Cct. 17
Cct. 18
Cct. 19
Cct. 21
Cct. 22
Cct. 23
Cct. 24
Cct. 25
Cct. 26
Cct. 27
Cct. 28
Circuits Control type Button Function
- - - - - - - - - 0% 0% 0% 0% - - - -
dimmable circuits
percentage values are place holders for circuit assignment to be determined by Lighting Consultant on commission
*Cct. 35
*Cct. 36
ExtCct.A
ExtCct.C
ExtCct.D
ExtCct.B
ExtCct.E
ExtCct.F
Cct. 10
Cct. 11
Cct. 12
Cct. 1
Cct. 2
Cct. 3
Cct. 4
Cct. 5
Cct. 6
Cct. 7
Cct. 8
Cct. 9
Circuits Control type Button Function
BMS TIMER 100% 100% 100% 100% 100% 100% - - - - - - - - - - - - - - - n/a n/a
IFF: seperate this cct for new
Control Panel 1 BUTTON corridor switch
Front Porch - - - - - - - 100% - - - - - - - - - - - - - on/off
Main Entrance 2way 3gang
Foyer - - - - - - - - 100% 100% 100% 100% - - - - - - - - - on/off
Control Panel 1a BUTTON
ground floor stairwell Foyer - - - - - - - - 100% 100% 100% 100% - - - - - - - - - 2way 1 gang on/off
Control Panel 1b BUTTON
ground floor foyer Guest WC - - - - - - - - - - - - - 100% 100% 100% 100% - - - - 1way 1 gang on/off
* Control Panel 8 BUTTON
ground floor stairwell Foyer - - - - - - - - - - - - 100% - - - - - - 100% 100% 2way 1 gang on/off
* Control Panel 8a BUTTON
1st floor stairwell Foyer - - - - - - - - - - - - 100% - - - - - - 100% 100% 2way 1 gang on/off
Control Panel 2 BUTTON
Utility Kitchen on/off - - - - - - - - - - - - - - - 100% 100% - - 1way 1 gang on/off
Cct. 33-35
Cct. 20*
Cct. 13
Cct. 14
Cct. 15
Cct. 16
Cct. 17
Cct. 18
Cct. 19
Cct. 21
Cct. 22
Cct. 23
Cct. 24
Cct. 25
Cct. 26
Cct. 27
Cct. 28
Cct. 29
Cct. 30
Cct. 31
Cct. 32
Circuits Control type Button Function
- - - - - - 0% 0% 0% 0% 0% 0% - - - - - -
Control Panel 7a BUTTON ExtCctA ExtCctB ExtCctC ExtCctD ExtCctE ExtCctF
Living Room external lighting 100% 100% 100% 100% 100% 100% - 100% - - - - - - - - - - - - on/off
Control Panel 7 BUTTON
Back Porch - - - - - - - - - - - - - - - - - 100% on/off
- - - - - - - -
Living Room Bright / Soft / - - - - - SPARE1 SPARE2 - -
IFF: it's
-
not-- correct
-
-
-
-
-
-
100%
70%
100%
40%
100%
0%
100%
100%
100%
100%
-
- 1way 2gang
toggle
Dining / Off - - - - - - - - - - - - 70% 100% 70% - - -
- - - - - - - - - - - - 0% 0% 0% 0% 0% -
Cct. 37
Cct. 38
Cct. 39
Cct. 40
Cct. 41
Cct. 42
Cct. 43
Cct. 44
Cct. 45
Cct. 46
Cct. 47
Cct. 48
Cct. 49
Cct. 50
Cct. 51
- - - - - 0% 0% 0% 0% 0% 0% 0% - - - - - - -
Cct. 52
Cct. 53
Cct. 54
Cct. 55
Cct. 56
Cct. 57
Cct. 58
Cct. 59
Cct. 60
Cct. 61
Cct. 62
Cct. 63
Cct. 64
Cct. 65
- - - - - 0% 0% 0% 0% 0% - - - - - - - -
dimmable circuits
percentage values are place holders for circuit assignment to be determined by Lighting Consultant on commission
CWL Lighting
info@ cwl-lighting.com www.cwl-lighting.com