33_11kV_Substation_Layout_With_Diagram

The document outlines the layout and measurements for a 33/11 kV substation, detailing the placement and size of various components such as transformers, circuit breakers, and control rooms. A component measurement table provides specific dimensions and positions for each element within a defined working area. The layout includes essential protective devices and metering equipment to ensure efficient operation of the substation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views1 page

33_11kV_Substation_Layout_With_Diagram

The document outlines the layout and measurements for a 33/11 kV substation, detailing the placement and size of various components such as transformers, circuit breakers, and control rooms. A component measurement table provides specific dimensions and positions for each element within a defined working area. The layout includes essential protective devices and metering equipment to ensure efficient operation of the substation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

33/11 kV Substation Layout with Measurements

Power Transformer

33 kV Line Tower

33 kV LA Isolator + CB CT/PT (33 kV)

Busbar
11 kV CB 1 11 kV CB 2 11 kV CB 3
2.0×2.0 cm 1.5×1.5 cm 2.5×1.5 cm 1.5×1.5 cm 20.0×0.2 cm

6.0×4.0 cm

2.0×2.0 cm 2.0×2.0 cm 2.0×2.0 cm

11 kV CT/PT

1.5×1.5 cm

Legend Box Control Room

Battery Room

6.0×4.0 cm 3.0×2.0 cm

10.0×6.0 cm

Component Measurement Table

Sr. No. Component Suggested Size (cm) Position on Sheet (Approx.) Remarks

1 Margin (All Sides) 2 cm All sides Keep diagram within 61×52 cm working area

2 33 kV Incoming Line 2×2 Top-left corner Line tower/pole symbol

3 Lightning Arrester (33 kV) 1.5×1.5 Right of incoming line Protection before isolator

4 Isolator + Circuit Breaker 2.5 wide block After LA Combined symbol

5 CTs/PTs (Metering) 1.5×1.5 After breaker Use rectangle or metering symbol

6 Power Transformer (33/11 kV) 6×4 Middle-left Main step-down transformer

7 Earth Switch/Earthing Grid Line below transformer Bottom left Dotted lines for earthing

8 11 kV Busbar Line ~20 cm long Horizontally from transformer Central horizontal position

9 Circuit Breakers (11 kV) 2×2 each Below busbar 4 to 6 feeders

10 CTs/PTs (11 kV) 1.5×1.5 each After each breaker For metering/protection

11 Lightning Arresters (11 kV) 1×1 Before outgoing feeders Optional per feeder

12 Outgoing 11 kV Feeders Arrows Right side of sheet 4–6 arrows with feeder labels

13 Control Room 6×4 Bottom-right corner For relays, SCADA, panels

14 Battery Room/Panel 3×2 Next to control room Auxiliary power source

15 Legend/Key Box 10×6 Bottom-left corner Symbol explanation, scale, title, etc.