0% found this document useful (0 votes)
0 views

1585-Cabo ethernet_SpecificationSheet

The document outlines the Ethernet Media Specifications, including updates on various cable types and their features, such as shielded and unshielded twisted-pair cables designed for harsh environments. It details the specifications for Rockwell Automation's Cat 5e Ethernet cables, including their construction, certifications, and suitable applications. Additionally, it includes product selection information for various RJ45 cordsets and patchcords, emphasizing their reliability and performance in industrial settings.

Uploaded by

noporks
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
0 views

1585-Cabo ethernet_SpecificationSheet

The document outlines the Ethernet Media Specifications, including updates on various cable types and their features, such as shielded and unshielded twisted-pair cables designed for harsh environments. It details the specifications for Rockwell Automation's Cat 5e Ethernet cables, including their construction, certifications, and suitable applications. Additionally, it includes product selection information for various RJ45 cordsets and patchcords, emphasizing their reliability and performance in industrial settings.

Uploaded by

noporks
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 24

Technical Data

Original Instructions

Ethernet Media Specifications


Bulletin Number 1585
Topic Page
Summary of Changes
This publication contains new and updated information
Summary of Changes 1
as indicated in the following table.
Introduction 2
Cable Spools 3 Topic Pages
Shielded Twisted-pair (Foil and Braided Shield) 4 Updated conductor AWG under IDC Connector Features 18
600V Ethernet Cable 5
RJ45 Cordsets and Patchcords 7
RJ45 Gigabit Cordset, Cat 6 9
RJ45 Red Cordset 10
M12 Flex-rated 11
M12 Receptacle Flex-rated 13
M12 Xcode Flex-rated Gigabit 15
M12 Red 16
RJ45 Field Attachable Connector 18
M12 Insulation Displacement Connectors (IDC) 20
M12 to RJ45 Bulkhead Connector 22
Additional Resources 23
Ethernet Media Specifications

Introduction
As Ethernet is increasingly used in industrial control, survival of physical media in rugged or harsh environments is
becoming a necessity. The high speed of network protocol allows it to be used in applications where other networks fall
short. EtherNet/IP™ uses both standard Ethernet and TCP/IP technologies and an open application layer protocol that
is called the Control and Information Protocol (CIP). This application layer is the same as used in DeviceNet® and
ControlNet® networks.

Rockwell Automation® Cat 5e Ethernet cables are designed to supply a network connection with excellent reliability in
harsh surroundings. By optimizing the balance of twisted-pair conductors inside a robust Thermoplastic Elastomer
(TPE) jacket, data is protected from noise, chemicals, and mechanical issues to M3I3C3E3 environmental protection
levels. The cable is available in RJ45 patchcords for IP20 applications or in four-pin D-coded M12 patchcords for IP67
applications where high vibration, fluids, and other contaminants can threaten the reliability of a network.

M12 D-code field attachable insulation displacement connectors (IDC) are available in both shielded and unshielded
housings with male or female connectors. Male eight-pin RJ45 connectors are available in both a crimp termination and
a toolless IDC connector for custom cabling.

Rockwell Automation M12 to RJ45 bulkhead connectors provide an elegant transition for network architecture from an
IP20 setting to an IP67 environment. The adapter can be used to connect remote junction boxes or implement an
On-Machine™ solution with Armor™ I/O products.

The Rockwell Automation Ethernet media portfolio provides connectivity with excellent reliability to maintain network
integrity and reduces costly downtime from troubleshooting.

2 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

Cable Spools
Specifications
Attributes Bulletin 1585
Certifications UL Listed and CEC
Cable type Unshielded 2- and 4-pair, Cat 5e
Unshielded Twisted-pair Ethernet Cable Spool
Conductor material Tinned copper stranded
Bend radius 10 million cycles at 20 x diameter (TPE cable)
Features Data rate Up to 1 GB/s
Operating temperature -40…+75 °C (-40…+167 °F)
• 4- and 8-conductor styles
Voltage 300V
• Unshielded cable types, Cat 5e
• 24 AWG conductors
• Twisted pairs maintain signal balance through Cable and Color Code
cable to provide high noise immunity and return Two-pair Four-pair
loss
• Designed to ODVA EtherNet/IP specifications
and ISO IEC 24702
• Suitable for high noise environments M3I3C3E3
• Riser PVC cables are used for general-purpose
environments
• TPE robotic cable is used for flex applications,
transmission-tested to 10 million cycles White/Orange White/Orange

• Plenum PVC cable is used for air duct applications White/Green Orange
Orange White/Green
• TPE cable meets channel transmission Green Blue
White/Blue
performance to 10 million flexes Green
White/Brown
Brown

Product Selection
Jacket No. of Jacket Wire Size Nominal Outer Operating
Material Cable Type Conductors Color [AWG] Diameter Temperature Cable Rating Cat. No.(1)
4 (two pairs) 5.6 mm (0.22 in.) 1585-C4TB-Sx
Teal Weld splatter, sunlight, and
Robotic TPE oil-resistant; UL CM, CMX; cUL CM; 1585-C8TB-Sx
-40…+75 °C Standard TIA 568-B, high flex rated
Unshielded 24 1585-C8VB-Sx
8 (four pairs) Red 5.84 mm (0.23 in.) (-40…+167 °F)
Plenum UL CMP; cUL CMG; Standard TIA 568-B 1585-C8MB-Sx
Riser PVC Teal UL CMR; cUL CMG; Standard TIA 568-B 1585-C8PB-Sx
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C4TB-Sx becomes 1585-C4TB-S600 for a 600 m cable).

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 3


Ethernet Media Specifications

Shielded Twisted-pair (Foil and Braided Shield)


Specifications
Attributes Bulletin 1585
Certifications UL Listed and CEC
Conductor material Tinned copper stranded
Insulation material High-density polyethylene
Shielded Ethernet Cable Spool
Bend radius 10 million cycles at 20 x diameter (TPE cable)
Data rate Up to 1 GB/s, Cat 5e
Voltage 300V
Features
• Four- and eight-conductor styles
Cable and Color Code
• Twisted-pair shielded cable types, Cat 5e
• Twisted pairs maintain signal balance through Two-pair Four-pair
cable to provide high noise immunity and return
loss
• Designed to ODVA EtherNet/IP specifications
and ISO IEC 24702
• Suitable for high noise environments M3I3C3E3
• Riser PVC cables used for general-purpose
environments
• PUR robotic cable used for flex applications, also White/Orange White/Orange
White/Green Orange
Halogen-free Orange White/Green

• 600V PVC cable designed to support high-voltage Green Blue


White/Blue
applications Green
White/Brown
• 600V On-Machine rated cable for use in a cable Brown
tray that is shared with high-voltage power cables

Product Selection
Jacket No. of Jacket Wire Size Nominal Outer Operating
Material Cable Type Conductors Color [AWG] Diameter Temperature Cable Rating Cat. No.(1)
5.84 mm
Riser PVC 8 (four pairs) UL CMR; cUL CMG; TIA-568-B 1585-C8CB-Sx
(0.23 in.)
Foil and -40…+75 °C
braided 4 (two pairs) 26 — 1585-C4UB-Sx
Teal (-40…+167 °F) C(ETL)US TYPE CMX; TIA 568-B,
Robotic PUR shield
6.2 ± 12 mm Flex rated, Halogen-Free
8 (four pairs) 1585-C8UB-Sx
(0.244 in.)
1585-C8HB-Sx
8 (four pairs)
Red (UL) CMX, CMR; c(UL) CMG; (UL) 1585-C8EB-Sx
8.13 ± 0.38 mm -20…+80 °C
600V PVC Foil shield 22 PLTC or AWM 2570 80 °C 600V;
Teal (0.32 in.) (-4…+176 °F) 1585-C4HB-Sx
TIA-568-B
4 (two pairs)
Red 1585-C4EB-Sx
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C8UB-Sx becomes 1585-C8UB-S600 for a 600 m cable).

4 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

600V Ethernet Cable


Specifications
Attributes Bulletin 1585
Certifications UL and c-UL Listed
Conductor material Thin copper stranded
Insulation material Perfluoroalkoxy copolymer and polyolefin
RJ45 Cordset—600V
Diameter 8.13 ± 0.38 mm (0.32 ± 0.015 in.)

Cable Rating UL, c-UL TYPE CMG; UL PLTC or UL AWM 2570 80C 600V, TIA
568B

Cable Spool Product Selection


Jacket No. of Jacket Wire Size Nominal Outer Operating
Material Cable Type Conductors Color [AWG] Diameter Temperature Cable Rating Cat. No.(1)
Teal 1585-C8HB-Sx
8 (four pairs)
Red 8.13 ± 0.38 mm -20…+80 °C (UL) CMX, CMR; c(UL) CMG; (UL) PLTC 1585-C8EB-Sx
600V PVC Foil shield 22
Teal (0.32 in.) (-4…+176 °F) or AWM 2570 80 °C 600V; TIA-568-B 1585-C4HB-Sx
4 (two pairs)
Red 1585-C4EB-Sx
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C4HB-Sx becomes 1585-C4HB-S600 for a 600 m cable).

RJ45 Cordsets RJ45 Patchcords

Shielding Cable Type Cat. No.(1)


8 conductor, teal 600V PVC 1585J-M8HB-x
No. of Jacket Cable
8 conductor, red 600V PVC 1585J-M8EB-x
Foil shield Conductors Material Type Cable Rating Angle Cat. No.(1)
4 conductor, teal, 600V PVC 1585J-M4HB-x
8 1585J-E8HBJM-x
(UL) CMX, CMR; Right
4 conductor, red, 600V PVC 1585J-M4EB-x c(UL) CMG; (UL)
4 Teal 600V Foil 1585J-E4HBJM-x
PLTC or
(1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable 8 PVC shield 1585J-L8HBJM-x
AWM 2570 80 °C
lengths (example 1585J-M8EB-x becomes 585J-M8EB-10 for a 10 m cable). 600V; TIA-568-B Left
4 1585J-L4HBJM-x
RJ45 Patchcords (1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable
lengths (example 1585J-E4HBJM-x becomes 1585J-E4HBJM-5 for a 5 m cable).

RJ45 IDC Connector


No. of Jacket Cable Insulation Diameter Cable Diameter
Conductors Material Type Cable Rating Cat. No.(1) [mm (in.)] [mm (in.)] Cat. No.
Teal 600V, 1585J-M8HBJM-x 0.85…1.6 (0.033…0.063) 5…9 (0.197…0.354) 1585J-M8CC-H
PVC
8
Red 600V (UL) CMX, CMR; c(UL) 1585J-M8EBJM-x
PVC Foil CMG; (UL) PLTC or
Teal 600V, shield AWM 2570 80 °C
600V; TIA-568-B 1585J-M4HBJM-x
PVC
4
Red 600V 1585J-M4EBJM-x
PVC
(1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable
lengths (example 1585J-M4HBJM-x becomes 1585J-M4HBJM-10 for a 10 m cable).

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 5


Ethernet Media Specifications

Cable and Color Code Approximate Dimensions [mm (in.)]


Four-pair
RH45IDC Connector
53.1 (2.09) Ref 29.3 (1.15) Ref

14.2
View (0.56)
Shown Ref
with Cap

13.9

B PC
12 87

12 87
(0.55)
Ref

White/Orange
6.6
Orange (0.26) 51.2 (2.02) Ref 13.8
White/Green Ref (0.054)
Ref
Blue
White/Blue
Green
White/Brown
View
Brown Shown
without Cap
Color Code 11.68
(0.46)
Face View RJ45 Pinout Ref
8-Pin
RH45 90° Left and Right Angle Patchcord
32 (1.25)

32 (1.25)
36.4 (1.4)

Color Code 8 7 6 5 4 3 2 1
36.4 (1.4)
1 White/Orange TxData +
2 Orange TxData -
3 White/Green Recv Data +
4 Blue Unused RH45 Cordset and Patchcord
A
5 White/Blue Unused 48.94 (1.93)
6 Green Recv Data -
7 White/Brown Unused
8 Brown Unused

6 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

RJ45 Cordsets and Patchcords


Specifications
Attributes Bulletin 1585J
Certifications UL Listed
Connectors RJ45 Male to RJ45 Male, Cat 5e
Unshielded 4- and 8-conductor, 24 AWG, Industrial Cat 5e
Cable type Shielded 8-conductor 26 AWG Industrial Cat 5e
Enclosure type rating IP20
Nominal outer diameter 5.84 mm (0.23 in.) ±10%
Features Operating temperature -20…+60 °C (-4…+140 °F)
Voltage 300V
• Flex-rated TPE, PVC, and plenum cables for
various applications
• Teal cable jacket Color Code
• Rugged strain relief and hitch mechanism to Face View RJ45 Pinout
maintain network integrity 8-Pin
• Suitable environments M3I3C3E3

Color Code 8 7 6 5 4 3 2 1

8-Pin 4-Pin
1 White/
Orange TxData + 1 White/
Orange TxData +
2 Orange TxData - TxData -
2 Orange
3 White/Green Recv Data + Recv Data +
A 3 White/Green
4 Blue Unused —
4—
5 White/Blue Unused —
5—
6 Green Recv Data - Recv Data -
6 Green
7 White/ Unused —
Brown 7—
Unused —
8 Brown 8—

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 7


Ethernet Media Specifications

Product Selection

Cat. No.(1)
No. of Jacket Cable Type Cable Rating
Conductors Material Straight to Right Angle to Left Angle to Right Angle to Left Angle to Right Angle to
Straight Straight Straight Left Angle Left Angle Right Angle
Teal riser, UL CMR; cUL CMG;
8 1585J-M8PBJM-y 1585J-E8PBJM-y 1585J-L8PBJM-y 1585J-E8PBJL-y 1585J-L8PBJL-y 1585J-E8PBJE-y
PVC Standard TIA 568-B
Weld splatter,
sunlight, and
Teal high- oil-resistant; UL CM,
8 1585J-M8TBJM-y 1585J-E8TBJM-y 1585J-L8TBJM-y 1585J-E8TBJL-y 1585J-L8TBJL-y 1585J-E8TBJE-y
flex, TPE outdoor; cUL CM;
Unshielded Standard TIA 568-B,
twisted pair flex rated
Weld splatter,
sunlight, and
Teal high- oil-resistant; UL CMG,
4 flex, TPE CMX; cUL CMG; 1585J-M4TBJM-y 1585J-E4TBJM-y 1585J-L4TBJM-y 1585J-E4TBJL-y 1585J-L4TBJL-y 1585J-E4TBJE-y
Standard TIA 568-B,
flex rated
Teal riser, UL CMR; CUR CMG,
8 PVC TIA B 1585J-M8CBJM-y 1585J-E8CBJM-y 1585J-L8CBJM-y 1585J-E8CBJL-y 1585J-L8CBJL-y 1585J-E8CBJE-y
Braid over
8 foil shield C(ETL)US TYPE CMX; 1585J-M8UBJM-y 1585J-E8UBJM-y 1585J-L8UBJM-y 1585J-E8UBJL-y 1585J-L8UBJL-y 1585J-E8UBJE-y
Teal high-
flex, PUR TIA 568-B, flex-rated,
4 halogen-free 1585J-M4UBJM-y 1585J-E4UBJM-y 1585J-L4UBJM-y 1585J-E4UBJL-y 1585J-L4UBJL-y 1585J-E4UBJE-y
8 Teal 1585J-M8HBJM-y 1585J-E8HBJM-y 1585J-L8HBJM-y 1585J-E8HBJL-y 1585J-L8HBJL-y 1585J-E8HBJE-y
Foil shield (UL) CMX, CMR; c(UL)
4 600V, PVC CMG; (UL) PLTC or 1585J-M4HBJM-y 1585J-E4HBJM-y 1585J-E4HBJM-y 1585J-E4HBJL-y 1585J-L4HBJL-y 1585J-E4HBJE-y
AWM 2570 80 °C
Teal riser, Crossover 600V; TIA-568-B
8 PVC cable 1585J-M8CBJM-yX 1585J-E8CBJM-yX 1585J-L8CBJM-yX 1585J-E8CBJL-yX 1585J-L8CBJL-yX 1585J-E8CBJE-yX

(1) Replace y with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable lengths (example 1585J-E8PBJE-y becomes 1585J-E8PBJE-5 for a 5 m cable).

Approximate Dimensions [mm (in.)]


48.94 (1.93)

Example of Cordset

Example of Patchcord

8 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

RJ45 Gigabit Cordset, Cat 6 Specifications


Attributes Bulletin 1585J
Certifications UL Listed
Connectors RJ45 Male to RJ45 Male, Cat 6
Cable type Shielded, 8-conductor, 24 AWG, Industrial Cat 6
Enclosure type rating IP20
Nominal outer diameter 5.84 mm (0.23 in.) ±10%
Operating temperature -20…+60 °C (-4…+140 °F)
Voltage 300V
Features
• Flex-rated TPE cables for various applications
Patchcords Product Selection
• Teal cable jacket
Connector Cable
• Rugged strain relief and latch mechanism to Shielding Style Cable Type Length Cat. No. (1)
maintain network integrity
RJ45 straight
1585J-M8TGJM-x
• Suitable environments M1I1C2E2 male
RJ45 straight
Foil and male to right 8-conductor (4 1585J-M8TGJE-x
2m
Cordsets Product Selection braided angle male pair), teal high- (6.56 ft)
shield flex TPE
RJ45 right
Connector Cable angle male to
Cat. No. (1) 1585J-E8TGJE-x
Shielding Style Cable Type Length right angle
Straight male 1585J-M8TG-x male
Foil and 8-conductor, teal 2m
braided Right angle (1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable
high-flex TPE (6.56 ft) 1585J-E8TG-x
shield male lengths (example 1585J-M8TGJE-x becomes 1585J-M8TGJE-2 for a 2 m cable).

(1) Replace x with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable
lengths (example 1585J-M8TG-x becomes 1585J-M8TG-5 for a 5 m cable). Color Code
Face View RJ45 Pinout
Approximate Dimensions [mm (in)] 8-Pin
48.94 (1.93)

Example of Cordset

Example of Patchcord Pin 1


Color Code Pin 8
Side A Plug Side B
Pin T568B Plug Pin 1000BASE-T
1 White/Orange 1 BI_DA+ (bidirectional pair 1+)
2 Orange 2 BI_DA- (bidirectional pair 1-)
3 White/Green 3 BI_DB+ (bidirectional pair 2+)
4 Blue 4 BI_DC+ (bidirectional pair 3+)
5 White/Blue 5 BI_DC- (bidirectional pair 3-)
6 Green 6 BI_DB- (bidirectional pair 2-)
7 White/Brown 7 BI_DD+ (bidirectional pair 4+)
8 Brown 8 BI_DD- (bidirectional pair 4-)

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 9


Ethernet Media Specifications

RJ45 Red Cordset


Specifications
Attributes Bulletin 1585J
Certifications UL Listed
Connectors RJ45 Male to RJ45 Male, Cat 5e
Unshielded, 4- and 8-conductor, 24 AWG, Industrial Cat 5e
Cable type
Shielded, 8-conductor, 26 AWG, Industrial Cat 5e
Wiring Enclosure type rating IP20
Face View RJ45 Pinout Nominal outer diameter 5.84 mm (0.23 in.) ±10%

8-Pin Operating temperature -20…+60 °C (-4…+140 °F)

Approximate Dimensions [mm (in.)]


48.94 (1.93)

Color Code 8 7 6 5 4 3 2 1
Example of Cordset
8-Pin 4-Pin
1 White/
Orange TxData + 1 White/
Orange TxData +
2 Orange TxData - TxData - Example of Patchcord
2 Orange
3 White/Green Recv Data + Recv Data +
A 3 White/Green
4 Blue Unused —
4—
5 White/Blue Unused —
5— Right Angle Left Angle
6 Green Recv Data - Recv Data -
6 Green
7 White/ Unused —
Brown 7— 31.70 (1.25)
Unused —
8 Brown 8—

Cable Spool Product Selection


Jacket No. of Jacket Wire Size Nominal Outer Operating
Material Cable Type Conductors Color [AWG] Diameter Temperature Cable Rating Cat. No.(1)
Teal 1585-C8HB-Sx
8 (four pairs)
Red 8.13 ± 0.38 mm -20…+80 °C (UL) CMX, CMR; c(UL) CMG; (UL) PLTC 1585-C8EB-Sx
600V PVC Foil shield 22
Teal (0.32 in.) (-4…+176 °F) or AWM 2570 80 °C 600V; TIA-568-B 1585-C4HB-Sx
4 (two pairs)
Red 1585-C4EB-Sx
(1) Replace x with 100 [100 m (328 ft)], 300 [300 m (984 ft)], or 600 [600 m (1969 ft)] for standard cable lengths (example 1585-C4HB-Sx becomes 1585-C4HB-S600 for a 600 m cable).

Patchcord Product Selection

Cat. No.(1)
No. of Jacket Cable Straight to Right Angle to Left Angle to Right Angle to Left Angle to Right Angle to
Conductors Material Type Cable Rating Straight Straight Straight Left Angle Left Angle Right Angle
Red riser, Weld splatter, 1585J-M8QBJM-y 1585J-E8QBJM-y 1585J-L8QBJM-y 1585J-E8QBJL-y 1585J-L8QBJL-y 1585J-E8QBJE-y
PVC sunlight, and
Unshielded oil-resistant; UL CM,
8 twisted
Red high outdoor; cUL CM;
pair
flex, TPE Standard TIA 568-B, 1585J-M8VBJM-y 1585J-E8VBJM-y 1585J-L8VBJM-y 1585J-E8VBJL-y 1585J-L8VBJL-y 1585J-E8VBJE-y
flex rated
(1) Replace y with 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable lengths (example 1585J-E8PBJE-y becomes 1585J-E8PBJE-5 for a 5 m cable).

10 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

M12 Flex-rated
Specifications
Attributes Bulletin 1585D
Coupling Nut Material Nickel-plated brass
4-Pin M12
D-Code Cordset Housing Material Polyurethane (PUR)
Contact material Gold-plated brass
Enclosure type rating IP67
Features Nominal outer diameter 5.84 mm (0.23 in.) ±10%
• Over molded housing suitable for IP67 Bend radius 10 x cable diameter
applications and harsh industrial environments Operating temperature -40…+75 °C (-40…+167 °F)
where extreme vibration, shock, chemicals, and
temperature are found.
• Flex-rated cable (must be tied down and not flexed
Cable Style
within 152 mm [6 in.] of the connector). Wire Size Cable O.D.
Cable Style Cable Type [AWG] [mm (in.)] Cable Rating
• Custom termination of single-ended cordsets with
one of several field attachable connectors. Weld splatter,
4 conductor, sunlight, and
TPE, high flex, unshielded
• Designed to ODVA EtherNet/IP specifications unshielded twisted-pair 24 5.6 (0.22) oil-resistant; UL CM,
CMX; c-UL CM; TIA
and ISO IEC 24702, IEC 61918. (UTP), teal 568B
• Twisted pairs maintain signal balance through PUR, foil and
cable to provide high noise immunity and return braided shield, 26 5.84 (0.23) C(ETL)US TYPE CMX;
high flex, 4 conductor, TIA 568B
loss. halogen free shielded
• Suitable for noise environments M3I3C3E3. twisted-pair (UL) CMX, CMR; c-UL
PVC, 600V (STP), teal CMG; (UL) PLTC or
rated, foil 22 8.13 (0.32) AWM 2570 80C
shield 600V; TIA 568B

M12 Cordset Product Selection

Cable Style First End Connector Second End Connector Operating Temperature Cat. No.
TPE, high flex, unshielded 1585D-M4TB-2
-40…+75 °C
PUR, foil and braided shield, (-40…+167 °F) 1585D-M4UB-2
high flex, halogen free Male M12 D-Code, straight Flying leads
-20…+80 °C
PVC, 600V rated, foil shield 1585D-M4HB-2
(-4…+176) °F

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 11


Ethernet Media Specifications

M12 Patchcord Product Selection

Cable Style First End Connector Second End Connector Operating Temperature Cat. No.
Male M12 D-Code, Straight Male M12 D-Code, Straight 1585D-M4TBDM-2
Male M12 D-Code, Right Angle 1585D-E4TBDE-2
TPE, high flex, unshielded Male M12 D-Code, Right Angle
1585D-M4TBDE-2
Male M12 D-Code, Straight Female M12 D-Code, Straight -40…+75 °C 1585D-M4TBDF-2
Male M12 D-Code, Straight (-40…+167 °F) 1585D-M4UBDM-2

PUR, foil and braided shield, high Male M12 D-Code, Right Angle 1585D-E4UBDE-2
Male M12 D-Code, Right Angle
flex, halogen free 1585D-M4UBDE-2
Male M12 D-Code, Straight Female M12 D-Code, Straight 1585D-M4UBDF-2
Male M12 D-Code, Straight 1585D-M4HBDM-2
Male M12 D-Code, Right Angle -20…+80 °C 1585D-E4HBDE-2
PVC, 600V rated, foil shield Male M12 D-Code, Right Angle
(-4…+176 °F) 1585D-M4HBDE-2
Male M12 D-Code, Straight
Female M12 D-Code, Straight 1585D-M4HBDF-2

M12 to RJ45 Patchcord Product Selection

Cable Style First End Connector Second End Connector Operating Temperature Cat. No.(1)
TPE, high flex, unshielded 1585D-M4TBJM-x
-40…+75 °C
PUR, foil and braided shield, high flex, (-40…+167 °F) 1585D-M4UBJM-x
halogen free Male M12 D-Code, straight RJ45
-20…+80 °C
PVC, 600V rated, foil shield 1585D-M4HBJM-x
(-4…+176 °F)
(1) Replace x with 1 [1 m (3.3 ft)], 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], or 10 [10 m (32.8 ft)] for standard cable lengths (example 1585D-M4UBJM-x becomes 1585D-M4UBJM-5 for a 5 m cable).

Accessories
Description Channel Bandwidth Cat. No.
RJ45 insulation displacement connector (IDC) Cat. 6 1585J-M8CC-H(1)
RJ45 crimp connector with boot Cat. 5e 1585J-M8CC-C(2)
(1) Qty. = 1 piece
(2) Qty. = 50 pieces

Approximate Dimensions [mm (in.)]


47 (1.85)

12 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

M12 Receptacle Flex-rated Specifications


Attribute Bulletin 1585D
Coupling Nut Material Nickel-plated brass
Contact material Gold-plated brass
Unshielded teal TPE, 4-conductor, stranded tinned wire,
Cable Type
Industrial Cat 5e
Enclosure type rating IP67
Nominal outer diameter 5.84 mm (0.23 in.) ±10%
4-Pin M12 D-Code Receptacle to RJ45 Patchcord Mounting Front-mount
Operating temperature -40…+75 °C (-40…+167 °F)
Cable Rating TIA 568B, flex-rated, 24 AWG, UL, c-UL
Features
Voltage 300V
• Suitable for IP67 applications and harsh industrial
environments where extreme vibration, shock,
chemicals, and temperature are found Color Code
• Flex-rated cable (cable must be tied down and not
flexed within 6 in. [152.4 mm] of the connector)
• Designed to ODVA EtherNet/IP specifications
Color
and ISO IEC 24702, IEC 61918 Code 8 7 6 5 4 3 2 1
• Twisted pairs maintain signal balance through 8-Pin 4-Pin
cable to provide high noise immunity and return 1 White/Orange TxData + 1 White/Orange TxData +
loss 2 Orange TxData - 2 Orange TxData -
• M12 D-code receptacle is suitable for noisy 3 White/Green Recv Data + 3 White/Green Recv Data +
A 4 Blue Unused 4— —
environments M3I3C3E3.
5 White/Blue Unused 5— —
6 Green Recv Data - 6 Green Recv Data -
7 White/Brown Unused 7— —
Color Code 8 Brown Unused 8— —

1 2 2 1

Color 4 4
3 3
Code
1 White-Orange 3 Orange
A
2 White-Green 4 Green

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 13


Ethernet Media Specifications

Connector Product Selection Color Code Pinout


Second Face View Pinout Face View RJ45 Pinout
First End End (Female)
Connector Connector Cable Type Cat. No.(1) 4-Pin
Unshielded twisted-pair,
4-conductor, teal TPE, 1585D-D4TBJM-x 1 2
Female M12 D- flex rated
Code Receptacle, RJ45
Front Mount Foil and braided shield, 4
conductor, teal PUR, flex 1585D-D4UBJM-x Color 4
rated, halogen-free Code 3 8 7 6 5 4 3 2 1

(1) Replace x with 1 [1 m (3.3 ft)], 2 [2 m (6.6 ft)], 5 [5 m (16.4 ft)], 10 [10 m (32.8 ft)], or 15 [15 1 White/Orange TxData +
m (49.2 ft)] for standard cable lengths (example 1585D-D4TBJM-x becomes 1585D-D4TBJM- 2 Orange TxData -
2 for a 2 m cable). 1 White/Orange 3 White/Green Recv Data +
2 White/Green 4 Blue Unused
A
3 Orange 5 White/Blue Unused
4 Green 6 Green Recv Data -
7 White/Brown Unused
8 Brown Unused

Approximate Dimensions [mm (in.)]


39 (1.54) Length 44.2 (1.74)
(see table)
19.5 (0.77) 19.5 (0.77)
M12 7.5
28 2 8 12 9
1.5 (0.06) (0.29)
(1.1) (0.08) (0.31) (0.47) (0.35)
Ø Ø
5.5 (0.22)
Ø
20/SW18 M12 x 1
Ø
PG9
x

x
G 2
Dia. M12 RJ45 1
PIN PIN 2
1 1 3
2 3 6
3 2
18 (0.71) 4 6
Ø

G
SW17

14 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

M12 Xcode Flex-rated Gigabit


Specifications
Attributes Bulletin 1585D
Coupling nut material Nickel-plated brass
Housing material Polyurethane (PUR)
Contact material Gold-plated brass
8-Pin M12 Xcode Cordset, Cat 6 Shielded teal PUR, 4 twisted pairs, 26 AWG, Industrial Cat 6,
Cable type
sunlight and oil-resistant
Nominal outer diameter 5.84 mm (0.23 in.) ±10%
Features Bend radius 10 x cable diameter
• Over-molded housing suitable for IP67 Cable rating Shielded: Standard TIA 568-B, ISO/IEC 11801, flex-rated,
26 AWG, halogen-free, Type CMX
applications and harsh industrial environments
where extreme vibration, shock, chemicals, and Enclosure type rating IP67

temperature are found. Operating temperature -40…+80 °C (-40…+176 °F)

• Flex-rated cable (must be tied down and not flexed


within 6 in. of the connector). Wiring Diagram
• Designed to EtherNet/IP specifications and ISO 1 1 White/Orange
2 2 Orange
IEC 11801, IEC 61918. 3
4
3 White/Green
4 Green
5 5 White/Brown
• Twisted pairs maintain signal balance through 6 6 Brown
7 7 White/Blue
cable to provide high noise immunity and low 8 8 Blue
return loss. GND
Connector pin assignment
GND
plug M12 Cat 6A
• Suitable for noise environments M3I3C3E3. pin side view

5 4
6 3

7 2
8 1

Product Selection
Patchcord Description Shielding Connector Style Cable Type Cable Length Cat. No.
M12 Xcode to M12 Xcode Shielded teal PUR, 4 twisted pairs, 26 AWG, 1585D-M8UGDM-1
Foil and braided shield Straight Male Industrial Cat 6, UL Listed, sunlight, and 1 m (3.28 ft)
M12 Xcode to RJ45 oil-resistant 1585D-M8UGJM-1

Approximate Dimensions [mm (in.)]


50 (1.97)

Example of M12 to M12 Patchcord Example of M12 to RJ45 Patchcord

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 15


Ethernet Media Specifications

M12 Red
Specifications
Attributes Bulletin 1585D
Coupling Nut Material Nickel-plated brass
4-Pin M12 D-Code Cordset Housing Material Polyurethane (PUR)
Contact material Gold-plated brass

Features Nominal outer diameter 5.84 mm (0.23 in.) ±10%


Enclosure type rating IP67
• Over molded housing suitable for IP67
Bend radius 10 x cable diameter
applications and harsh industrial environments
where extreme vibration, shock, chemicals, and
temperature are found. RJ45 Pinout
• Flex-rated cable (must be tied down and not flexed
within 6 in. of the connector).
• Custom termination of single-ended cordsets with
one of several field attachable connectors. Color
Code 8 7 6 5 4 3 2 1
• Designed to ODVA EtherNet/IP specifications
8-Pin 4-Pin
and ISO IEC 24702, IEC 61918.
1 White/Orange TxData + 1 White/Orange TxData +
• Twisted pairs maintain signal balance through 2 Orange TxData - 2 Orange TxData -
cable to provide high noise immunity and return A
3 White/Green Recv Data + 3 White/Green Recv Data +
4 Blue Unused 4— —
loss. 5 White/Blue Unused 5— —
6 Green Recv Data - 6 Green Recv Data -
• Suitable for noise environments M3I3C3E3. 7 White/Brown Unused 7— —
8 Brown Unused 8— —
M12 Pinout
1 2 2 1

Color 4 4
Code 3 3

1 White-Orange 3 Orange
A
2 White-Green 4 Green

16 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

Product Selection

First End Second End


Cable Style Connector Connector Operating Temperature Cat. No.
Red high flex TPE, unshielded -40…+75 °C 1585D-M4VBDM-2
Red high flex PUR, foil and braided shield, high flex, halogen free (-40…+167 °F) 1585D-M4FBDM-2
Male M12 D-Code, straight
-20…+80 °C
Red 600V PVC, 600V rated, foil shield 1585D-M4EBDM-2
(-4…+176 °F)

Approximate Dimensions [mm (in.)]


47 (1.85) Example of Cordset

Example of M12 to M12 Patchcord

Example of M12 to RJ45 Patchcord

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 17


Ethernet Media Specifications

RJ45 Field Attachable Connector


Specifications
Attribute Bulletin 1585J
Certifications UL Listed
Connector Type RJ45 male
RJ45 Insulation Displacement Connector (IDC)
Enclosure type rating IP20
RJ45 Crimp Operating temperature -40…+70 °C (-40…+158 °F)

IDC Connector Features


• 27...24 AWG (solid wire) or
27…22 AWG (stranded wire) conductors
• 360° shielding
• Reuse IDC connector up to five times
• No tools or conductor stripping required
• Cat 6

Crimp Connector Features


• 26…24 AWG
• Standard crimp connector with rugged boot
• Cat 5e

18 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

Product Selection
Electrical Insulation Channel
Description Connection Housing Material Material Contact Material Bandwidth Cat. No.
RJ45 insulation displacement 1585J-M8CC-H (1)
— Die-cast zinc Gold-plated copper Cat. 6
connector (IDC) Plastic alloy
RJ45 crimp connector with boot 150V, 1.5 A Clear polycarbonate Cat. 5e 1585J-M8CC-C (2)
(1) Qty. = 1 piece
(2) Qty. = 50 pieces

Face View RJ45 Pinout


Face View RJ45 Pinout
8-Pin

Color Code 8 7 6 5 4 3 2 1

8-Pin 4-Pin
1 White/Orange TxData + 1 White/Orange TxData +
2 Orange TxData - 2 Orange TxData -
3 White/Green Recv Data + 3 White/Green Recv Data +
A 4 Blue Unused 4— Unused
5 White/Blue Unused 5— Unused
6 Green Recv Data - 6 Green Recv Data -
7 White/Brown Unused 7— Unused
8 Brown Unused 8— Unused

Approximate Dimensions [mm (in.)]


RJ45 Insulation Displacement Connector (IDC)

12.9 11.6
(0.50) (0.46)

6.6 9.4
14.6 (0.26) (0.37)
(0.57)

51.3 (2.02)

RJ45 Crimp Connector


8.6
(0.34)

35.7
(1.4)

11.68 (0.46) 13.5


22.55 (0.89) (0.53)
8.18 (0.32) 7.47
(0.29) 12.32 (0.48)
4.38 (0.17) 9.71
(0.38) 8.6
6.60 7.92 (0.64)
6.10 (0.24) (0.26) (0.31)
6.5 (0.26)

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 19


Ethernet Media Specifications

M12 Insulation Displacement Connectors (IDC)


Specifications
Attribute Bulletin 1585D
Coupling Nut Material Zinc die-cast
Connector Shell Material Zinc die-cast or polyamide
Contact material Gold-plated brass
IDC Installations 10x, max.
Field Attachable
Unshielded: 26…22 AWG: 1.0…1.6 mm (0.04…0.063 in.);
Conductor OD
Shielded: 24…22 AWG: 1.2…1.6 mm (0.04…0.063 in.)

Features Assembly Rating 32V, 4 A


Enclosure type rating IP67
• Field installable with no hand tools needed
Operating temperature -25…+85 °C (-13…+185 °F)
• Straight male or female shielded versions Installation Temperature -5…+50 °C (23…185 °F)
• Allows easy modification of existing cable
installations
• Insulation displacement technology for secure
installation with excellent reliability
• Metal body unit excellent in shielding applications

Product Selection
Connector Cable Diameter Cat. No.
No. of Pins Material [mm (in.)] Wire Size, AWG Assembly Rating Dimensions Straight Female Straight Male
Polyamide small 4.0…5.1 26…22 See Figure A on page 21. — 1585D-M4DC-H
body unshielded (0.16…0.20)
4 32V, 4 A
Zinc die-cast large 5.5…7.2 24…22 See Figure B on page 21. 1585D-F4DC-SH 1585D-M4DC-SH
body shielded (0.22…0.28)

Face View Pinout Face View M12 Pinout


Color Code 4-Pin

1 2 2 1

4 4
3 3

1 White-Orange 3 Orange
A
2 White-Green 4 Green

20 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

Approximate Dimensions [mm (in.)]


M12 Insulation Displacement Connectors

15 (0.60)
20 (0.75)

Complete length when assembled approx. 43.45 (1.71)

M12 x 1

15.3 (0.60)
Dia.
Coupling Connector O-Ring Wire Cable Connector
Nut Body Gauge Stop Compression Shell
Ring
Figure A

51.7 (2.03) 47.8 (1.88)

19.5 19.5 SW13


(0.76) M12 x 1 SW13 (0.76) M12 x 1
Dia. Across flats Dia. Across flats

SW17 SW17
Across flats Across flats

Male Female
Figure B

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 21


Ethernet Media Specifications

M12 to RJ45 Bulkhead Connector


Specifications
Attributes Bulletin 1585A
Certifications UL Recognized for Canada and USA
Receptacle Shell Material Nickel-plated brass
Contact material Brass with nickel plating
Oil-resistant PVC, 22 AWG stranded copper, 300V,
Wire Insulation
UL recognized
Field Attachable
Assembly Rating 32V, 4 A
Enclosure type rating IP67, 1200 psi (8270 kPa) washdown
Operating temperature -20…+85 °C (-4…+185 °F)

Product Selection
Description Connector Panel Assembly Cat. No.
Material Mount Rating
Female M12 receptacle to Polyamide and
PG 9 22 AWG,
RJ45 female adapter right brass with nickel threads 32V, 4 A 1585A-DD4JD
angle plating

Approximate Dimensions [mm (in.)]


M12 to RJ45 Bulkhead Connector
Shielding from housing
over PCB to RJ45
M12 RJ45
1
15 1 2
(0.59) 16.5 3
2
(0.65) 3 100W 4
Dia. 15.4 5
(0.61) 4
6
100W 7
21.6 (0.85) Panel Cut Out 8
SW 20
Across
Flats
22.1 M16 x
(0.87) 1.5

M12 x 1
28.9 (1.14)
Nut 46.2 (1.82)
‘O’ Ring

22 Rockwell Automation Publication 1585-TD001F-EN-P - October 2019


Ethernet Media Specifications

Additional Resources
These documents contain additional information concerning related products from Rockwell Automation.
Resource Description
Industrial Ethernet Media Brochure, publication 1585-BR001 Provides an overview of Ethernet Media products that Rockwell Automation offers.
Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1 Provides general guidelines for installing a Rockwell Automation industrial system.
Product Certifications website, rok.auto/certifications. Provides declarations of conformity, certificates, and other certification details.

You can view or download publications at rok.auto/literature.

Rockwell Automation Publication 1585-TD001F-EN-P - October 2019 23


Rockwell Automation Support
Use the following resources to access support information.

Knowledgebase Articles, How-to Videos, FAQs, Chat,


Technical Support Center www.rockwellautomation.com/knowledgebase
User Forums, and Product Notification Updates.
www.rockwellautomation.com/global/support/get-support-
Local Technical Support Phone Numbers Locate the phone number for your country.
now.page
Find the Direct Dial Code for your product. Use the
www.rockwellautomation.com/global/support/direct-
Direct Dial Codes code to route your call directly to a technical support
dial.page
engineer.
Installation Instructions, Manuals, Brochures, and
Literature Library www.rockwellautomation.com/literature
Technical Data.
Get help determining how products interact, check
Product Compatibility and Download Center
features and capabilities, and find associated www.rockwellautomation.com/global/support/pcdc.page
(PCDC)
firmware.

Documentation Feedback
Your comments will help us serve your documentation needs better. If you have any suggestions on how to improve this document, complete the
How Are We Doing? form at http://literature.rockwellautomation.com/idc/groups/literature/documents/du/ra-du002_-en-e.pdf.

Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page.

Allen-Bradley, Armor, LISTEN. THINK. SOLVE., On-Machine, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc.
ControlNet, DeviceNet and EtherNet/IP are trademarks of ODVA, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400

Publication 1585-TD001F-EN-P - October 2019


Supersedes Publication 1585-TD001E-EN-P - April 2019 Copyright © 2019 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

You might also like