0% found this document useful (0 votes)
2 views

SIL-250

The Sani-Tech SIL-250 Series is a high-performance, platinum-cured silicone tubing designed for peristaltic pump applications, lasting up to five times longer than other similar products. It features minimal extractables, excellent fatigue resistance, and a smooth inner bore to reduce contamination risks, making it suitable for sensitive biopharmaceutical applications. The tubing complies with USP Class VI and FDA standards, ensuring safety and effectiveness in various fluid handling processes.

Uploaded by

Hatem Elkharadly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2 views

SIL-250

The Sani-Tech SIL-250 Series is a high-performance, platinum-cured silicone tubing designed for peristaltic pump applications, lasting up to five times longer than other similar products. It features minimal extractables, excellent fatigue resistance, and a smooth inner bore to reduce contamination risks, making it suitable for sensitive biopharmaceutical applications. The tubing complies with USP Class VI and FDA standards, ensuring safety and effectiveness in various fluid handling processes.

Uploaded by

Hatem Elkharadly
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Sani-Tech SIL-250 Series

Extended Life Silicone Tubing Specifications

BIOPHARMACEUTICAL PRODUCTS

High-performance,
platinum-cured silicone tubing
specifically designed for
peristaltic pump applications.
Features/Benefits
• Lasts Up to Five Times Longer Than
Other Platinum Silicone Tubings

• Minimal Extractables Help


© Saint-Gobain Performance Plastics
• Maintain Fluid Integrity
The excellent fatigue resistance properties of Sani-Tech® SIL-250 tubing make it an
ideal tubing selection for peristaltic pump systems • Ultra-Smooth Inner Bore Reduces
Potential for Particle Entrapment
Limits Risk of Fluid Contamination
Peristaltic pumping transports fluids efficiently, without risking contact with any
• Documented Biocompatibility for
Sensitive Applications
portion of the pump itself. To accomplish this, flexible tubing is inserted
between the pump rollers and housing. As the rollers rotate around a stationary • Excellent Fluid Flow Characteristics
rotor, the tubing is “squeezed” or occluded, pushing the fluid through the inside
tubing surface. As the tubing behind each roller recovers its shape, a vacuum is
• Taste-Free and Odor-Free
created, drawing additional fluid in behind the occluded tubing. During this
process, the fluid is contained entirely within the flexible tubing, eliminating
exposure (and risk of fluid contamination) to any components of the pump.
Typical Pump Applications
• Production Filtration and Fermentation
Reduces Potential Production Downtime
Sani-Tech® SIL-250 silicone tubing is formulated specifically for use in peristaltic • Sterile Fill Lines
pump applications. With its superior flex life characteristics, manufacturing
• Media Processing
processes can be simplified by reducing potential production downtime due to
pump tubing failure. (See Comparative Peristaltic Pump Tubing Life chart on • Cell Harvest Collection Systems
next page.)
• Chemistry and Blood Analysis
Prevents Residue Build-up • Liquid Chromatography
The smooth inner surface of Sani-Tech SIL-250 silicone tubing is designed to
help reduce the risk of particle entrapment and microscopic build-up during
sensitive fluid transfer. This smooth fluid path also can help to facilitate
complete sanitation of a fluid transfer system. Even in extended use
applications, Sani-Tech SIL-250 silicone tubing may help to prevent residue
build-up, aiding in more efficient cleaning and sterilization processes.

Platinum-cured Sani-Tech SIL-250 silicone tubing complies fully with the


requirements of the USP Class VI criteria and is entirely non-toxic, non-
hemolytic and non-pyrogenic. In addition, Sani-Tech SIL-250 silicone tubing
meets FDA 21 CFR Part 177.2600 criteria for use in food contact applications.

Used in a Range of Applications


Sani-Tech SIL-250 silicone tubing provides versatility in use for a broad range
of peristaltic pump applications. For situations requiring other uniquely
engineered properties, Saint-Gobain Performance Plastics can design a
formulation suited to meet your specific needs, including ultra-high temperature
resistance, electrical conductivity, pressure and vacuum resistance, pigmented
colors and closed cell sponge. Sani-Tech SIL-250 has a masterfile with the U.S
Food and Drug Administration.

High Purity Liquid Handling Products Page 1


for Pharmaceutical & Biotech Industries
(800) 726-4835 | www.sani-techwest.com
Sani-Tech SIL-250 Series
®

Extended Life Silicone Tubing Specifications

Sani-Tech® SIL-250 Available Sizes Typical Physical Properties


Minimum Property ASTM Method Value or Rating
Part Tubing Length Bend
Number Size (feet) (inches)* Durometer Hardness
D2240 55
SIL-250/125-1 1/8 x 3/16 50 3/8 Shore A, 15 Sec
SIL-250/125-2 1/8 x 1/4 50 1/2 Color — Translucent
Tensile Strength
SIL-250/156-1 5/32 x 7/32 50 3/4 D412 900 (6.2)
psi (MPa)
SIL-250/187-1 3/16 x 1/4 50 1
Ultimate Elongation,% D412 400
SIL-250/187-2 3/16 x 5/16 50 1/2
Tear Resistance D624
SIL-250/187-3 3/16 x 3/8 50 3/8 135 (23.6)
lb-f/inch (kN/m) Die B
SIL-250/187-4 3/16 x 7/16 50 3/8 Specific Gravity D792 1.12
SIL-250/250-1 1/4 x 5/16 50 1-1/2 Water Absorption,%
D570 0.16
SIL-250/250-2 1/4 x 3/8 50 1-1/2 24 hrs. @ 23°C
SIL-250/250-3 1/4 x 7/16 50 1-5/8 Compression Set
D395
SIL-250/250-4 1/4 x 1/2 50 5/8 Constant Deflection,% 5
Method B
@ 158°F (70°C) for 22 hrs.
SIL-250/312-2 5/16 x 7/16 50 1-1/4
Brittleness by Impact <-112°
SIL-250/312-3 5/16 x 1/2 50 5/8 D746
Temp., °F (°C) (<-80°)
SIL-250/375-2 3/8 x 1/2 50 1-1/2
Maximum Recommended
SIL-250/375-3 3/8 x 9/16 50 1 — 400 (204)
Operating Temp.,°F (°C)
SIL-250/375-4 3/8 x 5/8 50 1 Dielectric Strength 462
D149
SIL-250/437-1 7/16 x 9/16 50 1-1/2 v/mil (kV/mm) (18.2)
SIL-250/437-2 7/16 x 5/8 50 1-3/4 Tensile Modulus,
375 (2.6)
SIL-250/500-2 1/2 x 5/8 50 3 @ 100% Elongation, psi (MPa) D412
500 (3.4)
@ 200% Elongation, psi (MPa)
SIL-250/500-3 1/2 x 11/16 50 1-3/4
Tensile Set,% D412 6
SIL-250/500-4 1/2 x 3/4 50 1-1/2
Unless otherwise noted, all tests were conducted at room temperature (73ºF).
*Working pressures are calculated at a 1:5 ratio relative to burst pressure using ASTMD1599. Values shown were determined on 0.075" thick extruded strip or 0.075" thick
ADDITIONAL SIZES AVAILABLE UPON REQUEST.
molded ASTM plaques or molded ASTM durometer buttons.

The values listed for working and burst pressures are derived from tests
conducted under controlled laboratory conditions. Many factors will
reduce the tubing’s ability to withstand pressures, including temperature, Comparative Peristaltic Pump Tubing Life
chemical attack, stress, pulsation and the attachment to fittings. It is
imperative that the user conduct tests simulating the conditions of the The table below depicts hours until failure of 1/4" ID x 3/8" OD tubing. In each
application prior to specifying the tubing for use. case, a 3-roller pump head was utilized operating at 600 rpm at room
temperature (73°F). Tubing failure is measured in hours of use prior to rupture.

Sani-Tech® 75 Hours
SIL-250 Silicone
250 Hours
Tubing
Typical 25
Hours
Platinum-
50 Hours
Cured Silicone
50 100 150 250
Sani-Tech® is a registered trademark of
Saint-Gobain Performance Plastics. 10 psi back pressure 0 psi back pressure

The performance of tubing in peristaltic pumping applications is affected by the


conditions of use and equipment utilized, along with size and wall thickness of
the tubing tested. The data above is presented for information only and should
not be utilized for specification purposes.

SANI-TECH® TUBING IS NOT INTENDED


FOR USE AS AN IMPLANT MATERIAL

IMPORTANT: It is the user’s responsibility to ensure the suitability and safety of Saint-Gobain Performance Plastics tubing for all intended uses. Laboratory and clinical tests must be conducted in accordance with
applicable regulatory requirements in order to determine the safety and effectiveness for use of tubing in any particular application.
For a period of 6 months from the date of first sale, Saint-Gobain Performance Plastics Corporation warrants this product to be free from defects in materials and workmanship. Our only obligation will be to replace
any portion proving defective, or at our option, to refund the purchase price thereof. User assumes all other risk, if any, including the risk of injury, loss or damage, direct or consequential, arising out of the
use,misuse, or inability to use, this product. THIS WARRANTY IS IN LIEU OF THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE, AND ALL OTHER WARRANTIES, EXPRESSED OR IM-
PLIED. No deviation is authorized.
Saint-Gobain Performance Plastics Corporation assumes no obligations or liability for any advice furnished by it, or for results obtained with respect to those products. All such advice is given and accepted at the
buyer's risk.