The document outlines the preliminary and main building works for a construction project, detailing quantities, units, rates, and amounts for various tasks including excavation, concrete work, formwork, and roofing. It specifies requirements for materials and construction methods, referencing relevant standards and guidelines. Additionally, it includes provisions for temporary facilities and site management during the construction process.

Uploaded by

jennibuzy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views217 pages

BEME for building construction

The document outlines the preliminary and main building works for a construction project, detailing quantities, units, rates, and amounts for various tasks including excavation, concrete work, formwork, and roofing. It specifies requirements for materials and construction methods, referencing relevant standards and guidelines. Additionally, it includes provisions for temporary facilities and site management during the construction process.

Uploaded by

jennibuzy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 217

BILL NR 1 - PRELIMINARIES

ITEM DESCRIPTIONS QTY UNIT RATE


AB BILL NR. 1 - PRELIMINARIES Item
CD Allow for the provision of the following preliminary Item
EF items Setting out of the work Item
GH Watching and lighting item
JK Temporary buildings Item
Temporary welfare and sanitary facilities Regular item
cleaning item
Cleaning at completion item
Plant and Scalfold for the work Progress reports and item
photographs Water for the works item
Temporary electricity
PRELIMINARIES CARRIED TO GENERAL SUMMARY


PL/3
BILL NR 2- MAIN BUILDING
Building Works
PRELIMINARIES
AMOUNT
S/N DESCRIPTION QTY UNIT RATE AMOUNT
BILL NO. 2- MAIN BUILDING (BUILDING WORKS)
SUBSTRUCTURE (ALL PROVISIONAL)

WORK UP TO FLOOR SLAB


Nature and location of the work The work in this section
comprises:
(i) Limited demolition below ground where existing and new
foundations conflict
(ii) Excavation, earthfilling, column bases, strip foundation
under walls, blockwork and concrete work to floor slab (DPC)
(iii) The contractor is however referred to the various
Architectural and
Structural drawings in relation to this section for the nature
and content of the work to be executed.
(iv) The contractor is hereby reminded of the necessity to keep
accurate
records authenticated by the Project Architects or his duly
authorised representative as no variations would be
entertained unless duly certified.
SUPPLEMENTARY PREAMBLES
Carting away of excavated material
Descriptions of carting away of excavated material shall be
deemed to include loading excavated material onto trucks
directly from the excavations or, alternatively, from stock piles
situated on the building site
Pricing of Working Space allowance to Excavation
Excavation, disposal, backfilling and compaction with suitable
excavated or imported materials, work below ground water
level, and breaking out are deemed to be included in the
pricing.
Reinforcement
Bars will be specified to comply with the British standard BS
4449. Specifically, bar diameter sizes 10mm, 12mm, 16mm
and 20mm shall have the mass per unit length (kg/m) of
0.617, 0.888, 1.579 and 2.467 respectively. Tenderer should
note this and price accordingly.
EXCAVATION, FILLING, ETC OTHER THAN BULK
Excavating
Top soil for preservation
average 150 deep
Excavation in compacted earth maximum depth not exceeding
2m deep (Working space inclusive)
Ground beam
Ditto; but bulk excavation in lift shaft
CARTING AWAY
Extra over all excavations for carting away
Surplus material from excavations on site

1100 m2
A 142 m3
BC 19 m3
D 161 m3

Carried to collections
S/N DESCRIPTION QTY UNIT RATE AMOUNT
RISK OF COLLAPSE
Risk of collapse of excavations to deep excavations
A Sides of trench and hole excavations exceeding 2m deep 316 m2

B Sides of tlift shaft excavations exceeding 2m deep 25 m2


C Keeping excavations free of water Item
Keeping excavations free of water

EARTH FILLING, ETC.

Earth filling obtained from the excavations compacted to 95%


ModAASHTO density
D Backfilling to trenches, holes, etc 76 m3

Hardcore filling from prescribed stockpiles on site of crushed b


uilding material and suitable for sub-
grade material compacted in 150mm layers
to 93% Mod AASHTO
E Under surface beds 75 m3

Imported sand fillng supplied by the Contractor from a comme


rcial source and suitable for sub-
grade material compacted in 150mm layers
to 95% Mod AASHTO
F G2 Sub base layer under surface beds average thickness 180 m3
exceeding 1m
COMPACTION

Compaction of surfaces
G Compaction of ground surface under floors etc including 70 m2
scarifying for a depth of 150mm, breaking down oversize
material, adding suitable material where necessary and
compacting to 90% Mod AASHTO density
SOIL POISONING

Soil insecticide
H Apply 'Dieldrex 20' to under floors etc including forming and 531 m2
posioning shallow furrows against foundation walls etc, filling
in furrows and ramming
UNREINFORCED CONCRETE CAST AGAINST EXCAVATED
SURFACES
10MPa/19mm concrete
J Surface blinding against earth and unblinded sand 19 m3
REINFORCED CONCRETE
25MPa/19mm concrete

K Ground beam 63 m3

L Lift shaft 3 m3

M Surface slabs and steps cast in panels on waterproofing 73 m3

Carried to collections
S/N DESCRIPTION QTY UNIT RATE AMOUNT
FORMWORK
Sawn formwork to sides generally
A Ground beam 422 m2

B Sides of lift base 20 m2

C Edges of slab, risers and ends not exceeding 300mm high or 88 m


wide
Reinforcement bars; B.S. 4449, hot rolled ribbed, high yield ste
el; straight,bent and curved
D 16-20mm Diameter bars in ground beam 7.875 t
E 10 - 25mm Diameter bars in ground floor slab 8.395 t

F 10 - 25mm Diameter bars in Lift shaft 0.45 t


DAMP PROOF MEMBRANE
One layer of 1000 micron waterproof sheeting sealed at laps w
ith Pressure Sensitive Tape

G Plain areas, horizontal; laid loose including sealing edge to 367 m2


concrete
PROVISIONAL WORKS
For undefined work
H Allow for additional work in foundation 1 Sum

Carried to collections
COLLECTION
Page/1
Page/2
Page/3

Element No. 1
Subsructure carried to Summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No. 2: FRAME
E05: In situ concrete
25MPa/19mm concrete

A Columns 58 m3

B Beam 125 m3

C Slab 234 m3

D Lift wall 22 m3
E20: Formwork for in situ concrete Formwork and basic finish

E To sides of column 596 m2

F To sides and soffit of beams 1230 m2

G To edges of floor slab 305 m

H To soffit of slab 1429 m2

J Lift wall 302 m2

K To edges of lift opening 27 m


E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489 in

L Bar, 10- 25mm diameter in column 8.7 t

M Bar, 10- 25mm diameter in beam 18.75 t

N Bar, 10- 12mm diameter in slab 26.91 t

P Bar, 10- 12mm diameter in slab 3.3 t

Element No. 2
Frame carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No. 3 ROOF AND ROOF COVERING
E05: In situ concrete
25MPa/19mm concrete

A Beams 30 m3

B Gutter and Slab 19 m3

C Copping 2 m3
E20: Formwork for in situ concrete
Formwork and basic finish (Marine plywood)

D Roof beams, regular shaped, rectangular 321 m2

E soffit and faces of gutter 128 m2

F soffit and edges of Roof copping 87 m2


E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489

G Bar, 10-16mm diameter 7.65 t


H72: Galvanized ,Aluminum sheet covering
"Tower or any equal and approved" 0.75mm guage, corrugate
d
longspan aluminuim roofing sheet lapped and fixed in accorda
nce with
manufacturer's instruction to purlins including coating surface
in contact with other materials with bituminous material
H Roof covering 378 m2

J Ridge capping 110 m


G20: Carpentry
Sawn treated hardwood roof members impregnated with solignum

K 50mm x 150mm Rafters 258 m

L 50mm x 75mm Purlins 538 m

M 50mm x 100mm Struts 586 m

N 50mm x 150mm King post 50 m

P 50mm x 150mm Tie beam 381 m

Q 50mm x 150mm Wall plate 111 m

Carried to collections
S/N DESCRIPTION QTY UNIT RATE AMOUNT
SUNDERIES
150 mm Fulbora cast iron roof outlet complete with grouting
and built into
concrete
A 150mm diameter drain pipes 6 Nr
M10: sand cement screeds
40mm thick Cement-
sand (1:3) one coat screed on concrete work

B Roofs, level and to falls only not exceeding 150 from 68 m2


horizontal
Manhole
C Allow a provision for manhole on the roof slab 2 nr
WATERPROOFING
J41: BUILT-UP FELT ROOF COVERING
Waterproofing of roof shall be laid under a ten year gurantee.
Waterproofing to roofs shall be laid to even falls to outlets etc
with necessary ridges, hips and valleys.

D 2 x 4.5mm Scudoplast felting or approved waterproof 68 m2


membrane laid on screeded bed in accordance with
manufacturers details in roof slab, gutter floor and wall

Carried to collections
COLLECTION
Page/5
Page/6

Element No. 3
Roof covering and Structure carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
AMOUNT
ELEMENT No.4: STAIRCASES
E05: In situ concrete
25MPa/19mm concrete

A Staircases and Landing 17 m3


E20: Formwork for in situ concrete Formwork and basic finish

B Soffit of string, thickness not exceeding 175mm thickness 56 m2


sloping > 150
C Soffit of landings, thickness not exceeding 200mm, horizontal 23 m2

D Edges of sloping staircase string cut to profile 56 m

E Edges of landings, 150mm high 52 m

F Faces of risers, 150mm high 203 m


E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489 in

Staircases
G Bar, 10-16mm diameter 2.55 t
Surface finishes
M20: Plastered/Rendered/ roughcast coatings
Cement-
sand (1:4) one coat external rendering on block or concrete
work

H Soffit of slabs, thickness not exceeding 200mm thickness 56 m2


sloping > 150
J Soffit of landings, thickness not exceeding 200mm, horizontal 23 m2

K Edges of stair strings, to profile 56 m


Surface finishes
M10: sand cement screeds

40mm Cement-sand (1:3) one coat screed on concrete


L Floors, level and to falls only not exceeding 150 to horizontal 23 m2
12mm Cement-sand (1:3) one coat screed on concrete

M Risers ; plain, 150mm high 203 m

N Treads; 300mm wide 195 m

P Skirtings; 100mm wide 94 m

Carried to collections
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.4: STAIRCASES (CONT'D)
M40:Stone/Concrete Quarry/Ceramic tilling/ Mosaic
Porcelain martle floor tiles size 600mm x 300mm laid on cement an
d sand beds in approved pattern

A Floors, level and to falls only not exceeding 150 to horizontal 23 m2

B Risers ; plain, 150mm high 203 m

C Treads; 300mm wide 195 m

D Skirtings; 75mm high inluding cement mortar backing 94 m


M60: Painting / Clear Finishing
Berger luxol or any equal and approved emulsion paint as
manufactured by applied in 2coats to rendered walls, complying to
Architect's details.

E General surfaces, width exceeding 300mm 79 m2

F General surfaces, width not exceeding 300mm 56 m

L30:Stairs/Walkways/ Balustrades
G Stair balustrade; made of black pipe 1.2m high fixed complete 94 m
with all accessories including plugging into blockwork or
concrete

Carried to collections
COLLECTION
Page/7
Page/8

Element No. 4
Stairs carried to Summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.5: EXTERNAL AND INTERNAL WALLS
F10: Brick and blockwalling
Vibrated hollow sancrete blocks in cement mortar (1:6) laid in
stretcher bond

A Walls 230mm thick, vertical 1301 m2

B Ditto but; 150mm thick 129 m2


E05: In situ concrete
Reinforced in situ concrete 30MPa/19mm aggregate

C Lintel 2 m3

E20: Formwork for in situ concrete to:


Formwork and basic finish
D Sides and soffit of Lintel 33 m2

E Sides of lift wall 686 m2


E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489 in Lintel:

F Bar, 10-16mm diameter in lintel 0.24 t


CURTAIN WALLING
Semi-frameless structural Curtain walling with slim exposed
profile doubled glazed with 6mm + 6mm + 0.378mm PVB (Polyvinyl
butyral)

laminated tinted and reflective safety glass cut to sizes complete


in accordance with Arch drawings with and including all
necessary windows obtainable from reputable manufacturer or
fabricator
Overall size 14185mm x 2230mm high
G 3 no
H Overall size 13700mm x 2230mm high 3 no

J Overall size 13450mm x 2230mm high 3 no

K Overall size 9200mm x 2230mm high 3 no

L Ditto size 8000mm x 10260mm high 1 no

M Ditto size 6725mm x 3150mm high - Shopfront 1 no

N Ditto size 2000mm x 10260mm high - Shopfront 1 no

P Featured panel, as designed size 5700mm x 10260mm high - 1 no


side

Element No. 5
External and Internal walls carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT

ELEMENT No.6 : WINDOWS AND DOORS


L20: Timber Doors
Supply and fix; Interior quality; single panel single swing
Isreali Security door with high fire
resistance complete with architraves and
ironmongeries in accordance to architect's details to fit openin
g size.
A Overall size 750mm x 2100mm high. 23 Nr
B Overall size 900mm x 2100mm high. 21 Nr

C Overall size 1800mm x 2400mm high. 1 Nr


Revolving Door

D Supply and fix overhead canopy with high strength aluminium 1 1


alloy, 6mm toughened glass revolving door, curved fixed glass
9mm clear laminated glass

Element No. 6
Window and Doors carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.7: WALL FINISHES
External and Internal
M20: Plastered/Rendered/ roughcast coatings
Cement-
sand (1:4) one coat external rendering on block or concrete work

A Walls, width exceeding 300mm 2860 m2

B Walls, width not exceeding 300mm wide 503 m


M31: Fibrous plaster
Plaster of paris (P.O.P) precast screedings to walls internally
trowelled smooth, one coat

C Walls, width exceeding 300mm 2255 m2

D Walls, width not exceeding 300mm wide 503 m


M60: Painting / Clear Finishing
Berger luxol paint or approved equal Emulsion paint as
manufactured by applied in 2coats to rendered walls, complying to
Architect's details.

E General surfaces, width exceeding 300mm 2255 m2

F Walls, width not exceeding 300mm wide 503 m


M40:Stone/Concrete Quarry/Ceramic tilling/ Mosaic
Approved 300 x 600mm ceramic( porcelain) wall tiles laid on
cement and sand backing in approved pattern

G Walls. Width exceeding 300mm wide 605 m2

H Walls, width not exceeding 300mm wide 120 m

M20: Plastered/Rendered/ roughcast coatings


12mm thick cement and sand (1:4) floated backing to blockwall
surfaces to receive further finishes
J Walls, width exceeding 300mm wide 605 m2

K Walls, width not exceeding 300mm wide 120 m

Element No. 7
Wall finishes carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.8: CEILING FINISHES
M20 12mm thick Gypsum board ceilings
with galvanised steel support, smooth rendering, one coat to
general surfaces complying to Architect' details

A Ceilings; width exceeding 300mm wide - Concierge 94 m2


M20: Plastered/Rendered/ roughcast coatings
Cement-sand (1:4) one coat fair finishes to soffit of slab in ground
floor

B Soffit of slab in ground floor 272 m2


M31: Fibrous plaster
Plaster of paris (P.O.P) screedings internally trowelled smooth, on
e coat

C Ceilings; width exceeding 300mm wide 94 m2

D Soffit of slab in ground floor 272 m2


M60: Painting / Clear Finishing
Berger clinstay Emulsion paint applied in Two coats to rendered
walls , complying to Architect's details.

E General surfaces; width exceeding 300mm wide 94 m2

F Soffit of slab in ground floor 272 m2


G20: Carpentary/ timber framing
Sawn treated hardwood in ceilings

G Noggins 50mm x 50mm 505 m


SUSPENDED CEILING
"Emel" or other equal and approved 600 x 600 x 20mm white
acoustic
suspended demountable acoustic ceiling tiles laid in and
including concealed aluminium grid and shadow gap edge
detail with all necessary
H aluminium string and hangers for lateral support in accordance 1,443 m2
with manufacturer's fixing details
600 x 600mm Ceiling suspended not exceeding 1.00m from
concrete soffit

Element No. 8
Ceiling finishes carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.9- FLOOR FINISHES
Surface finishes
M10: sand cement screeds
38mm thick Cement-sand (1:3) one coat screed on concrete work

A Floors, level not exceeding 150 from horizontal 199 m2


M40:Stone/Concrete Quarry/Ceramic tilling/ Mosaic
Approved porcelain glazed floor tiles, laid on cement and sand
backing in approved pattern
600 x 600mm vitrified floor tiles laid on cement and sand backing i
n approved pattern
Floors, level not exceeding 150 from horizontal in

m2
B Open Office, stairhall. Services, Kitchennette and toilets 199

C Skirting 725 m

Element No. 9
Floor finishes carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
A ELEMENT No.10 FITTINGS AND FIXTURES PS
A54: Provisional work
Include a provisional sum for Kitchen cabinets

Element Nr.10
Fittings and fixtures Carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
SUMMARY ,
SUBSTRUCTURE
FRAME
ROOF COVERING AND STRUCTURE
STAIRCASE
INTERNAL AND EXTERNAL WALLS
WINDOWS AND DOORS
WALL FINISHES
CEILINGS FINISHES
FLOOR FINISHES
FITTING AND FIXTURES

BILL NR 3-MAIN BUILDING CARRIED TO GENERAL SUMMARY


BILL NR 3- SECURITY AND GENERATOR
Building Works
R
S/N DESCRIPTION QTY UNIT RATE AMOUNT
BILL NO. 3- SECURITY AND GENERATOR HOUSE(BUILDING
WORKS)
SUBSTRUCTURE (ALL PROVISIONAL)

WORK UP TO FLOOR SLAB


Nature and location of the work The work in this section
comprises:
(i) Limited demolition below ground where existing and new
foundations conflict
(ii) Excavation, earthfilling, column bases, strip foundation
under walls, blockwork and concrete work to floor slab (DPC)
(iii) The contractor is however referred to the various
Architectural and
Structural drawings in relation to this section for the nature
and content of the work to be executed.
(iv) The contractor is hereby reminded of the necessity to keep
accurate
records authenticated by the Project Architects or his duly
authorised representative as no variations would be
entertained unless duly certified.
SUPPLEMENTARY PREAMBLES
Carting away of excavated material
Descriptions of carting away of excavated material shall be
deemed to include loading excavated material onto trucks
directly from the excavations or, alternatively, from stock piles
situated on the building site
Pricing of Working Space allowance to Excavation
Excavation, disposal, backfilling and compaction with suitable
excavated or imported materials, work below ground water
level, and breaking out are deemed to be included in the
pricing.
Reinforcement
Bars will be specified to comply with the British standard BS
4449. Specifically, bar diameter sizes 10mm, 12mm, 16mm
and 20mm shall have the mass per unit length (kg/m) of
0.617, 0.888, 1.579 and 2.467 respectively. Tenderer should
note this and price accordingly.
EXCAVATION, FILLING, ETC OTHER THAN BULK
Excavation in compacted earth maximum depth not exceeding
2m deep (Working space inclusive)
Ground beam
CARTING AWAY
Extra over all excavations for carting away Surplus material
from excavations on site

A 17 m3
B 17 m3

Carried to collections
S/N DESCRIPTION QTY UNIT RATE AMOUNT
RISK OF COLLAPSE
Risk of collapse of excavations to deep excavations
A Sides of trench and hole excavations exceeding 2m deep 55 m2
B Keeping excavations free of water Item
Keeping excavations free of water

EARTH FILLING, ETC.

Earth filling obtained from the excavations compacted to 95%


ModAASHTO density
C Backfilling to trenches, holes, etc 25 m3

Hardcore filling from prescribed stockpiles on site of crushed b


uilding material and suitable for sub-
D grade material compacted in 150mm layers 5
to 93% Mod AASHTO
m3

Imported sand fillng supplied by the Contractor from a comme


rcial source and suitable for sub-
grade material compacted in 150mm layers
to 95% Mod AASHTO
E G2 Sub base layer under surface beds average thickness 19 m3
exceeding 1m
COMPACTION

Compaction of surfaces
F Compaction of ground surface under floors etc including 24 m2
scarifying for a depth of 150mm, breaking down oversize
material, adding suitable material where necessary and
compacting to 90% Mod AASHTO density
SOIL POISONING

Soil insecticide
G Apply 'Dieldrex 20' to under floors etc including forming and 77 m2
posioning shallow furrows against foundation walls etc, filling
in furrows and ramming
UNREINFORCED CONCRETE CAST AGAINST EXCAVATED
SURFACES
10MPa/19mm concrete
H Surface blinding against earth and unblinded sand 1 m3
REINFORCED CONCRETE
25MPa/19mm concrete

J Ground beam 8 m3

K Surface slabs and steps cast in panels on waterproofing 5 m3

Carried to collections
S/N DESCRIPTION QTY UNIT RATE AMOUNT
FORMWORK
Sawn formwork to sides generally
A Ground beam 21 m2

B Edges, risers and ends not exceeding 300mm high or wide 30 m

BRC mesh
C Brc wire mesh 32 m2
Reinforcement bars; B.S. 4449, hot rolled ribbed, high yield ste
el; straight,bent and curved

D 16-20mm Diameter bars in ground beam 0.8 t


DAMP PROOF MEMBRANE
One layer of 1000 micron waterproof sheeting sealed at laps w
ith Pressure Sensitive Tape

E Plain areas, horizontal; laid loose including sealing edge to 23 m2


concrete
PROVISIONAL WORKS
For undefined work
F Allow for additional work in foundation 1 Sum

Carried to collections
COLLECTION
Page/1
Page/2
Page/3

Element No. 1
Subsructure carried to Summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No. 2: FRAME
E05: In situ concrete
25MPa/19mm concrete

A Columns 3 m3

B Beam 1 m3
E20: Formwork for in situ concrete Formwork and basic finish

C To sides of column 36 m2

D To sides and soffit of beams 31 m2


E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489 in

E Bar, 10- 25mm diameter in column 0.345 t

F Bar, 10- 25mm diameter in beam 0.115 t

Element No. 2
Frame carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No. 3 ROOF AND ROOF COVERING
E05: In situ concrete
25MPa/19mm concrete

A Roof slab 6 m3
E20: Formwork for in situ concrete
Formwork and basic finish (Marine plywood)

B soffit and edges of Roof beam slab 53 m2


E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489

C Bar, 10-16mm diameter 0.69 t

SUNDERIES
150 mm Fulbora cast iron roof outlet complete with grouting
and built into
concrete
D 150mm diameter drain pipes 2 Nr
M10: sand cement screeds
40mm thick Cement-
sand (1:3) one coat screed on concrete work

E Roofs, level and to falls only not exceeding 150 from 43 m2


horizontal
Manhole
F Allow a provision for manhole on the roof slab 0 nr
WATERPROOFING
J41: BUILT-UP FELT ROOF COVERING
Waterproofing of roof shall be laid under a ten year gurantee.
Waterproofing to roofs shall be laid to even falls to outlets etc
with necessary ridges, hips and valleys.

G 2 x 4.5mm Scudoplast felting or approved waterproof 43 m2


membrane laid on screeded bed in accordance with
manufacturers details in roof slab, gutter floor and wall

Element No. 3
Roof covering and Structure carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.4: EXTERNAL AND INTERNAL WALLS
F10: Brick and blockwalling
Vibrated hollow sancrete blocks in cement mortar (1:6) laid in
stretcher bond

A Walls 230mm thick, vertical 104 m2


E05: In situ concrete
Reinforced in situ concrete 30MPa/19mm aggregate

B Lintel 1 m3

E20: Formwork for in situ concrete to:


Formwork and basic finish
C Sides and soffit of Lintel 10 m2
E20: Reinforcement for in situ concrete
High yield deformed bar reinforcement to B.S 4489 in Lintel:

D Bar, 10-16mm diameter in lintel 0.15 t

Element No. 5
External and Internal walls carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.5 : WINDOWS AND DOORS
"White Epoxy" powder coated aluminum coated outward five(5) ba
y
wndow with 3 fixed panels complete with aluminium lever handles,
double glazing in 6mm grey tinted glass, 12mm void filled with
Argon gas & 2-
layers of 3mm clear glass with 0.37PVB ; complying
to Architect details
A Ditto size 450mm x 1200mm high 1 Nr

B Ditto size 1800mm x 1200mm high 1 Nr

C Ditto size 2800mm x 1200mm high 3 Nr


Grille

D 1165mm x 2100mm 1 Nr

E 1145mm x 2100mm 1 Nr
2345mm x 2100mm
F L20: Timber Doors 1 Nr
Supply and fix; Interior quality; single panel single swing
Isreali Security door with high fire
resistance complete with architraves and
ironmongeries in accordance to architect's details to fit openin
g size.

G Overall size 750mm x 2100mm high. 1 Nr

H Overall size 900mm x 2100mm high. 1 Nr

Element No. 6
Window and Doors carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.6: WALL FINISHES
External and Internal
M20: Plastered/Rendered/ roughcast coatings
Cement-
sand (1:4) one coat external rendering on block or concrete work

A Walls, width exceeding 300mm 208 m2


M31: Fibrous plaster
Plaster of paris (P.O.P) precast screedings to walls internally
trowelled smooth, one coat

B Walls, width exceeding 300mm 208 m2


M60: Painting / Clear Finishing
Berger luxol paint or approved equal Emulsion paint as
manufactured by applied in 2coats to rendered walls, complying to
Architect's details.

C General surfaces, width exceeding 300mm 188 m2


M40:Stone/Concrete Quarry/Ceramic tilling/ Mosaic
Approved 300 x 600mm ceramic( porcelain) wall tiles laid on
cement and sand backing in approved pattern

D Walls. Width exceeding 300mm wide 20 m2

M20: Plastered/Rendered/ roughcast coatings


12mm thick cement and sand (1:4) floated backing to blockwall
surfaces to receive further finishes
E Walls, width exceeding 300mm wide 20 m2

Element No. 7
Wall finishes carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.7: CEILING FINISHES
M20: Plastered/Rendered/ roughcast coatings
Cement-sand (1:4) one coat fair finishes to soffit of slab in ground
floor

A Soffit of roof slab 43 m2


M31: Fibrous plaster
Plaster of paris (P.O.P) screedings internally trowelled smooth, on
e coat

B Soffit of slab in ground floor 43 m2


M60: Painting / Clear Finishing
Berger clinstay Emulsion paint applied in Two coats to rendered
walls , complying to Architect's details.

C Soffit of slab in ground floor 43 m2

Element No. 8
Ceiling finishes carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
ELEMENT No.8- FLOOR FINISHES
Surface finishes
M10: sand cement screeds
38mm thick Cement-sand (1:3) one coat screed on concrete work

A Floors, level not exceeding 150 from horizontal 25 m2


M40:Stone/Concrete Quarry/Ceramic tilling/ Mosaic
Approved porcelain glazed floor tiles, laid on cement and sand
backing in approved pattern
400 x 400mm unglazed porcelain mattle floor tiles laid on cement
and sand backing in approved pattern in wet areas

B Security, Toilet and Generator house 25 m2

Element No. 9
Floor finishes carried to summary
S/N DESCRIPTION QTY UNIT RATE AMOUNT
SUMMARY ,
SUBSTRUCTURE
FRAME
ROOF COVERING AND STRUCTURE
INTERNAL AND EXTERNAL WALLS
WINDOWS AND DOORS
WALL FINISHES
CEILINGS FINISHES
FLOOR FINISHES

BILL NR 3-MAIN BUILDING CARRIED TO GENERAL SUMMARY


BILL NR 4- ELECTRICAL INSTALLATIONS
BILL NO. 4: ELECTRICAL SERVICES INSTALLATIONS
ITEM DESCRIPTION QTY UNIT RATE SUPPLY RATE FIXED N
N

Preliminaries

1 Interpretation procedure, Mobilisation and site Sum


organisation
Construction documents: Design and Workshop
2 Drawings, Submittals e.t.c Sum

4 Record drawings, operation and maintenance manual Sum

Sub Total (Carried forward To Collection)

ITEM DESCRIPTION QTY UNIT RATE SUPPLY RATE FIXED N


N
A POWER SUPPLY

Allow a PROVISIONAL SUM for statutory charges by


Utility provider and others which shall include
provision of overhead aluminium conductors, cross
arm, insulators, concrete poles and other accessories
1 1 lot
for overhead power intake, Metering panel, Survey,
Connection, Testing and Commissioning of electrical
equipment with other related charges.

GENERATORS
Supply, install, test and commission a Prime Rated
250KVA, 415V, 50HZ, 1500 RPM, ACOUSTIC
2 GENERATING SET 1 No.
complete with all necessary accessories.
PERKINS OR APPROVED EQUAL

3 Allow for earthing with heavy duty copper earth rods, 1 lot
earth cables, earth bar and other accessories for the
LV PANEL and GENERATORS to obtain Earth
Resiatance (R<1).
HT Supply & Transformer 1 No.
Supply and Install 200KVA 11/0.415kV 50Hz OIL
Immersed ONAN type step down
transformer,complete with metering unit (Installation
cost to include cost for terminations,earthing etc to
PHCN standard and in accordance with Statutory
Regulations
ABB/SCHNEIDER
Sub-Total A To Collection
AMOUNT N

AMOUNT N
-
ITEM DESCRIPTION QTY UNIT RATE SUPPLY RATE FIXED N
N

B MAIN & FINAL DISTRIBUTION BOARDS

Supply,Install and commision the following main and


final distribution boards
1 MAIN LOW VOLTAGE PANEL (MLVP)
Supply, install, test and commission a 12-Way 400A
4P MCCB SUB-LV panel complete with all digital
metering accessories,indicators and surge protection
and 1no 400A 4P
MCCB as incomer
2nos 100A 3P MCCB and the following outgoing MCCBs.
1nos 63A 3P MCCB
SCHNEIDER or Approved Equal. 1 No.

2 SITE LIGHTING PANEL/BOARD

Supply, install, test and commission a 4-Way 32A 4P


Lighting Panel/Distribution Baord complete with 32A
4-Pole DIN Contactor incomer complete with Photocell
and the following
outgoing
2nos 10A MCBs.
3P MCB
6nos 10A SPN MCB
SCHNEIDER EASY 9. 1 No.
ISOLATOR SWITCHES (ABB OR SCHNEIDER)

400A 4P MCCB in an Enclosure Complete with


Indicator Lights
3 4 No.

4 400A 4P CHANGEOVER SWITCH in an Enclosure 4 No.


Complete with Indicator Lights

5 32A TPN Isolator switch (LIFT) 1 No.

FINAL DISTRIBUTION BOARDS

6 63A 8-Way TPN MCB type distribution board in an 1 No.


enclosure complete with 63A TPN ELCB, mixed
capacity MCBs.
SCHNEIDER or approved equal
SCHEINDER EASY 9 - EZ9ET24L
7 63A 12-Way TPN MCB type distribution board in an 4 No.
enclosure complete with 63A TPN ELCB, mixed
capacity MCBs.
SCHNEIDER or approved equal
SCHEINDER EASY 9 - EZ9ET36L
8 100A 12-Way TPN MCB type distribution board in an 16 No.
enclosure complete with 100A TPN ELCB, mixed
capacity MCBs. SCHNEIDER or approved equal
SCHEINDER EASY 9 - EZ9ET36L
Sub-Total B To Collection
C LOAD CABLES AND CONTAINMENTS
Supply, installation, testing and commissioning of the
cables
for power distribution as manufactured by COLEMAN o
r Approved Equal.
(PROVISIONAL - ALL CABLES ARE ESTIMATED
LENGTH. HENCE, ACTUAL LENGTH TO BE RE-
MEASURED ON

SITE)
1core 240mm² PVC/PVC copper cable for NEAREST
PHCN SUPPLY - LV PANEL (3P+N)

1 75 m
1core 120mm² PVC Earth cable. 75 m
1core 240mm² PVC/PVC copper cable for GEN SET - LV
2 PANEL (3P+N) 90 m

1core 120mm² PVC Earth cable. 90 m


3 4core 16mm² PVC/PVC copper cable for all DBs 369 m
1core 16mm² PVC Earth cable. 369 m
4 4core 10mm² PVC/PVC copper cable for LIFT 38 m
1core 10mm² PVC Earth cable. m
5 100mm UPVC Pipe Sleeve (3.5mm Thick) 369 m

6 75mm UPVC Pipe Sleeve (3.5mm Thick) 38 m

7 50mm Coruugated UPVC Pipe Sleeve (3.5mm Thick) 90 m


8 Allow for cables lugs,Cable glands and other 1 Lot
installation accessoeies for complete installation of
the cables
Sub-Total C To Collection
D LIGHTING FITTINGS
Supply, installation and commissioning of all lighting fittings
including bulbs, lamps and control gears to 0.8pf. Lamps and
Luminairies; Spec Supply and install
Luminaires and Lamps with and including all accessories
necessary for complete installation

120W, (LED) High Quality LED Luminaire Mounted on


1 a 8 Meter High Galvanised Steel Pole (Building 14 No.
Perimeter)
2 1 X 40W (E27) IP44 Wall Bulk Head Luminare. REF: 3 No.
Massive
3 1 X 20W (LED) Ceiling Mounted Luminaire. REF: 8 No.
Velmax
1 X 36W (LED) Ceiling Mounted Luminaire (1200M x
4 600MM) REF: Velmax 18 No.

5 1 X 18W (LED) Aqua Proof Luminaire. REF: Velmax 51 No.

1 x 40W (LED) Ceiling Mounted Luminaire (600MM X


6 600MM). REF: Velmax 141 No.

1 X 8W (LED) 3Hrs Non Maintained Emergency


7 Luminaire With Exit Sign Legend. REF: Ansell 35 No.

1 X 20W (LED) IP65 Decorated Wall Luminaire C/W


8 Accessories REF: Velmax 12 No.
9 1 X 40W (LED) Ceiling Mounted Emergency Luminaire 42 No.
(600MM x 600MM). REF: Velmax
Sub-Total D To Collection
E SWITCHES, SOCKETS AND ACCESSORIES SWITCHES
All Switches shall be Legrand Belanko or aprroved

2 10A 2-gang, 2-way switch 26 No.

3 10A 3-gang, 3-way switch 12 No.


SOCKETS
All Sockets shall be Legrand Legrand Belanko or
aprroved

5 Twin 13A Switch Socket Outlet. 97 No.

6 Single 15A IP65 Switch Socket Outlet 3 No.

7 20A D.P Switch for AC 33 No.

7 20A D.P Switch for Hand Dryer 13 No.

Screeded Floor Box. 2 x 13A 2-Gang Socket and 2


6 Module RJ45 Outlet 99 No.

7 Dual RJ 45 Voice Outlet. 6 No.

7 10A Ceiling Rose Outlet. 6 No.


Sub-Total E To Collection

F CONDUITING AND WIRING CABLES


Supply and Installation of all wiring cables to be
drawn into PVC Conduit pipes for all the final sub-
circuit observing all the wiring installation Regulation
and colour code. - All cables to
be COLEMAN
Pipes: or other approved equal
DIGNITY
Lighting points using 1.5mm2 Sc Copper Cable in
1 20mm PVC conduit 282 No.

13A Sockets outlets Power point using 2.5mm2 sc


2 copper cable in 20mm Dia. PVC Pipe 100 No.

20A AC outlets Power point using 4.0mm2 sc copper


3 cable in 25mm Dia. PVC Pipe 33 No.

4 External Lighting points using 5C x 6.0mm2 PVC/PVC 42 No.


Copper Cable in 50mm heavy duty PVC conduit
including connection block and MCB
Sub-Total F To Collection
G EARTHING AND BONDING
Provide and Install the complete Earthing and Bonding
System of the entire Electrical Systems
of the entire Electrical Systems of LT Panel Board,
Distribution

Boards, External Lighting


to IEE Regulations Standards. (FURSE)
Earth copper rods 1.22m x 15mm dia.

1 25 No.
2 Earth rod couplings 15 No.

3 Earth rod clamps 5 No.

70mm bare copper tape (PROVISIONAL - ACTUAL


4 LENGTH TO BE DETERMINE ON SITE) 180 m

5 600mm x 600mm x 6mm lattice copper earth mat 5 No.

300x300mm PVC Earth inspection Pit - LIGHTWEIGHT


6 (FURSE) 5 No.

7 Allow for Resistivity Testing 1 Lot


8 Other installation materials and accessories including 1 Lot
civil works to achieve a complete Earthing systems
with an ohmic reading of LESS than 1.0 0hm
Sub-Total L To Collection
H LIGHTNING PROTECTION
Supply, install and test lightning protection system for the
entire building . The system
shall consist of mesh air termination, down conductors, test

clamps and ground termination.


Except as specified below, all items shall be FURSE
Non-radioactive electronic lightning arrestor

1
INDELEC Preventron 3 S6.60 1 No.
2 Earth copper rods 1.22m x 15mm dia. 5 No.

3 Earth rod couplings 3 No.

4 Earth rod clamps 1 No.

5 Screw down test clamp 1 No.

6 Bare earth copper tape 25mm x 3mm 40 m

7 Allow for steel mast support for item 1 above 1 lot

8 600mm x 600mm x 6mm lattice copper earth mat 1 No.

9 300x300mm PVC Earth inspection Pit - LIGHTWEIGHT 1 No.


(FURSE)

10 Allow for all other accessories such as clips, joints,etc 1 lot


necessary for complete installation of lightning
protection system
11 All other items such as biological materials, soil 1 lot
conditioning agents, etc, to complete the earthing
system and improve the conductivity of the soil.
Sub-Total M To Collection
N FIRE DETECTION AND ALARM SYSTEM
1 Supply, install and test fire detection and alarm system . The
system shall consist of smoke detector, fire alarm, heat
detector, fire hose and other associated works.
Optical Smoke Detector

REF: Gent 60 No.


2 Heat Detector 8 No.

3 Break Glass Manual Call Point 7 No.

4 12V D.C Fire Alarm Bell 11 No.

5 Weather Proof Fire Alarm Bell 2 No.

6 Fire Alarm Control Panel 1 m

7 Fire Extinguisher 12 lot

8 Fire Man Hose 4 No.

9 7.5KW Lowara Fire Pak Pump Set (Electric Dieswl 2 No.


Jockey) Complete Pressure Vessel Capable of
Delivering 2,5 Liters/Sec at a Head of 25m

10 50mm steel fire control system pipe 30 m


11 Allow for a provisional sum for all other fire 1 lot
equipments and fittings
Sub-Total M To Collection
N SECURITY/CCTV SYSTEM
1 Supply, install and test security and CCTV System. The
system shall consist of projector, dome camera, high speed
camera and other associated works.
High Speed Dome Digital Camera

REF: Dosch 11 No.


2 Motorized Weather Proof High Speed Camera 27 No.

Ceiling Mounted Projector C/W 13A Power Socket &


3 RJ45 Access Point 3 No.

4 Emergency Release Button 6 No.

5 Magnetic Lock with Armature 7 No.

6 Door Closer Button 7 No.


7 Proximity Reader Button 4 No.
Sub-Total M To Collection
COLLECTION
POWER SUPPLY

B MAIN & FINAL DISTRIBUTION BOARDS

C LOAD CABLES AND CONTAINMENTS

D LIGHTING FITTINGS

E SWITCHES, SOCKETS AND ACCESSORIES

F CONDUITING AND WIRING CABLES

G EARTHING AND BONDING

H LIGHTNING PROTECTION

I SECURITY/CCTV SYSTEM
J FIRE DETECTION AND ALARM SYSTEM
SUBTOTAL (Carried forward to Collection)
COLLECTION

1 BILL NO. 1: PRELIMINARIES

2 BILL NO. 2: ELECTRICAL SERVICES INSTALLATIONS

SUB-TOTAL
BILL NR 5- ELV INSTALLATIONS
AMOUNT N

-
-
-
-
-
-
-
-
-
-
-
-
-

-
-

-
ITEM BILL No. 5 - ELV INSTALLATIONS QTY UNIT BASIC FIXED
DESCRIPTION RATE RATE
1 ELV SUPPLY AND INSTALLATION
Supply, Installation, testing and commissioning of
30kVA

Solar Power Equipments, Batteries, Panels


Controllers etc.
A 4 Nr
20kva , 96V, hybrid INVERTER (Felicity Brand)

B 120AH MPPT Charge Controller (120AH, Felicity 8 Nr


Brand)
C 17.4KWH LITHIUM BATTERY 4 Nr

D 10mm power control cables 200 m

Mono Crystalline Solar Panel (450Watts german


E panels) (450w) 120 Nr

F Solar- Panel Rack 45 Nr

G 10mm Flexible Solar power cables 170 m

H 35mm Flexible Power Battery cables 36 m

J Batteries Tie & Cable Clips 1 Nr

K By-Pass Change -Over (Side Handle) 1 Nr

L AC Breakers (For Protection) 1 Nr

M PV Junction box / combiner 1 Nr

N 100A MCCB TP&N AC Isolating Switch 1 Nr

P 100A, 415V MCCB TP&N for AC Panel 1 Nr

Q 4 x 25mm2 XLPE/PVC/SWA/PVC Copper Cable 70 m

Sub Total (CarrIed Forward To Summary)


BILL NR 6- PLUMBING INSTALLATIONS
TOTAL
COST

-
ITEM Section 1 - SANITARY APPLIANCES QTY UNIT BASIC FIXED
DESCRIPTION RATE RATE
1 BILLNO. 6 - PLUMBING INSTALLATIONS
Supply and install the following:

Colour to Architects specification 18 Set


comprising:
Water closet:- (1No)
- Water closet comprising:
- Close Coupled system
dual flush actuator pan connector, seat and cover
soft
close
and all necessary fixing accessories
Wash basin:- (1No) 20 Set
- Wash basin with semi pedestal
- Chrome Plated Bottle trap and waste
connections
Basin Mixer and fixing accessories
Toilet Accessories 18 Set
Colour to Architects specification
comprising:
- Tissue Holder
- Towel Hanger
Angle Valves and flexible
and all necessary fixing accessories

Water Heater (Not Specified on the drawing)


TO Collection
TOTAL
COST
-
BASIC RATE FIXED
Section 2 - COLD AND HOT WATER SERVICES RATE
ITEM QTY UNIT
DESCRIPTION

1 Supply and install the following: 24 m m


ii ii iii Pipework shall be PPR except if stated otherwise. 113 m m
iv iv Note that stated sizes are indicative of nominal 38 m m
iv internal dimensions. 36 Nos
2 Pipes 19 Nos
i. ii iii 15mm PPR 6 Nos
iv 20mm PPR 8 Nos
3 25mm PPR 4 Nos
i. iii 32mm PPR 21 Nos
4 38mm PPR 125 Nos
ii iii 50mm PPR 12 Nos
6 Elbow 45 Nos
iii iv 20mm x 15mm 15mm 10 Nos
v vi 20mm 25mm 8 Nos
7 Tee 15mm 20mm 12 Nos
i. Reducers 25 x 20 mm 10 Set
8 32 x 25 mm PPR 10 Nos
8 Isolating Valve e.g Crane 20mm 8 Set
10 25mm 25mm PPR 1 Set
32mm PPR 1
WaterTreatment Unit 1
Allow for treatment System (Not in the drawing, 2
Could be expunged) 1
Treated water tank - Braithwaite (Estimated
@10,000 litre capacity) Capacity not stated on the
drawing
Water Booster
Duty and standby water booster pump set with 50
litres vessel
rated 2.1 l/s 30mH (Not stated on the drawing)
Transfer Pump
Duty and standby water booster pump set with 50
litres vessel
rated 2.7 l/s 30mH (Not stated on the drawing)
Miscellaneous e.g. Anchors bolts, threaded rods,
transition fittings etc

TOTAL TO Collection
TOTAL COST

-
Section 3- SOIL, DRAINAGE & RAINWATER
BASIC FIXED
ITEM SERVICES QTY UNIT
DESCRIPTION RATE RATE
Supply and install the following:
(Pipework shall be UPVC Fit for abover and Under
ground use Except indicated otherwise)
1 Pipes
i. 50mm 38 m
iii 100mm 38 m
iv 150mm 52 m
2 Elbows 88.5 deg
i. 50mm 10 Nos
iii 100mm 8 Nos
iv 150mm 10 Nos
4 Tees 88.5 deg branch
i. 50mm 5 Nos
iv 100mm 4 Nos
v 150 x 100mm 3 Nos
5 Tees 45 deg branch
i. 50mm 5 Nos
ii 100 x 50mm 10 Nos
6 Reducers
i. 100 x 50mm 6 Nos
ii 150 x 100mm 24 Nos
8 Floor Clean Out
i 100mm Access pipe 12 Nos
ii Weather Cap for pipes e.g. Vent cowls Lot

9 Miscellaneous e.g. Anchors bolts, threaded rods Lot


etc

TO Collection
TOTAL

COST

-
COLLECTION
Section 1 - Sanitary Appliances (Installation only)
Section 2 - Water Services
Section 3 - Drainage Services

TOTAL TO PLUMBING SUMMARY


BILL NR 7- HVAC INSTALLATIONS
NGN
-
-
-

-
ITEM BILL No. 7 - HVAC INSTALLATIONS QTY UNIT BASIC FIXED
DESCRIPTION RATE RATE
1 AIR CONDITIONING SYSTEMS SUPPLY AND 3 Nr
AB INSTALLATION 1 Nr
CD Daikin, Panasonic or equal and approved 5 Nr
EF Airconditioning Unit including sales, testing and 9 Nr
G commissioning 12 Nr
H CEILING MOUNTED DUCTED-TYPE SPLIT AIR 15 Nr
J CONDITIONING UNITS 1 Lot
K Equipment: Daikin, Panasonic or other approved 1 Lot
L equal, 1 Lot
M 1 Lot
Single split air conditioning system complete with all 18 Nr
accessories necessary for installation 1 Lot
OUTDOOR UNIT
84 kw cooling capacity fresh air unit
22.4 kw cooling capacity fresh air unit
CASSETTE-TYPE VRF INDOOR UNITS
4.5 kw cooling capacity - Diffuser (Windfree 4way)
2.2 kw cooling capacity - Indoor wall mounted
MSP DUCT TYPE AIR CONDITIONING SYSTEM
9.0 kw cooling capacity
12.80 kw cooling capacity
REFRIGERANT LINE ACCESSORIES
Supply, install, test and charge the following copper
pipe refrigerant lines for the air conditioning units
above with all necessary fittings as recommended by
manufacturer.
CONDENSATE DRAIN LINE
Supply, install and test the UPVC pipe with insulation
to connect to drain as shown in drawing.
ELECTRICAL CABLING
Communication cable interconnecting all the indoor
units and their corresponding outdoor unit and
controllers serving individual indoor AC units
CONSUMABLES
Allow for Duct-tapes, Gasket, Thread tape, Brazing
Rod, Adhesive Gum, Sealant, Tangit Gum, Unistrut,
Beam Clamp and other necessary materials for
complete installation.
WALL MOUNTED FAN (TOILET BATH) - EF-05
Model:XPELAIR DX100 or approved equivalent
MISCELLANEOUS
Allow for leakage test

Sub Total (CarrIed Forward To Summary)


BILL NR 8 - LIFT
TOTAL
COST

-
ITEM BILL No. 8 - LIFT SYSTEM QTY UNIT BASIC FIXED
DESCRIPTION RATE RATE
A Otis or Kone elevator including sales, testing 1 No
and commissioning for 650kg 4stops

Sub Total (CarrIed Forward To Summary)


Lift/ 2
BILL NR 9- EXTERNAL WORKS
Building Works
TOTAL
COST
-

-
RKS
S/N DESCRIPTION QTY UNIT RATE
A
B BILL NO. 9 - EXTERNAL WORKS

Q10 KERBS/EDGINGS/CHANNEL/PAVING ACCESSORIES

125mm thick x 225mm high precast concrete kerbs with fair faced
finish; bedded and fixed on in-situ concrete foundation and haunching 86 m
(measured altogether)
PAVING (internal) 546 m2
Installation of interlocking paving on site and Provide insitu cast
Stamped concrete floor to external parking, all according to architect
design

Kerbs / Paving
carried to External Works summary
S/N DESCRIPTION QTY UNIT RATE
A FENCE WORK
B EXCAVATION, FILLING, ETC OTHER THAN BULK
C
D Excavation in compacted earth maximum depth not exceeding 2m dee
E p inclusive
F of Working space allowance to excavation not exceeding 2.0m deep; in
G cluding
H additional earthwork support, disposal and backfilling with selected exc
J avated
material compacted
Ground beam to 95% Mod AASHTO density 600mm away from fa
excavation 80 m3

CARTING AWAY

Extra over all excavations for carting away


Surplus material from excavations and/or stock piles on site 80 m3

RISK OF COLLAPSE

Risk of collapse of excavations to deep excavations


Sides of trench and hole excavations exceeding 2m deep 176 m2
Keeping excavations free of water Item
Keeping excavations free of water

EARTH FILLING, ETC.

Earth filling obtained from the excavations compacted to 95% ModAAS


HTO density
Backfilling to trenches, holes, etc 45 m3

COMPACTION
Compaction of surfaces
Compaction of ground surface under floors etc including scarifying for a 35 m2
depth of 150mm, breaking down oversize material, adding suitable
material where necessary and compacting to 90% Mod AASHTO density

SOIL POISONING
Soil insecticide
Apply 'Dieldrex 20' to under floors etc including forming and posioning 307 m2
shallow furrows against foundation walls etc, filling in furrows and
ramming
UNREINFORCED CONCRETE CAST AGAINST EXCAVATED SURFACES

10MPa/19mm concrete
Surface blinding against earth and unblinded sand 2 m3

REINFORCED CONCRETE

25MPa/19mm concrete
Footing 35 m3

Carried to Collection
AMOUNT
AMOUNT
AMOUNT
S/N DESCRIPTION QTY UNIT RATE
BLOCKWORK
Sandcrete hollow blockwork, bedded and jointed in cement and sand m
ortar (1:6) in 4.5 Mpa min.
A Walls; 230 thick; stretcher bond 354 m2
B DAMP PROOF COURSE m
One layer of 1000 micron waterproof sheeting sealed at laps with Press
ure Sensitive Tape
Plain areas, horizontal; laid loose including sealing edges to concrete

SECURITY GATE

C Supply and fix complete fully finished aluminum double swing gate at 1 nr
3m high, fully finished to architect specification. Size 4.000mm wide x
3.000m high
D Single folding security steel gate at 120mm high, fully finished to 1 nr
architect specification. Size 4.000mm wide x 3.000m high
External and Internal
M20: Plastered/Rendered/ roughcast coatings
Cement-sand (1:4) one coat external rendering on block or concrete work

E Walls, width exceeding 300mm 708 m2


M60: Painting / Clear Finishing
Berger clinstay Emulsion paint applied in Two coats to rendered walls ,
complying to Architect's details.

F General surfaces; width exceeding 300mm wide 708 m2

Carried to Collection
Collecton
Page/2
Page/3

FENCING CARRIED TO EXTERNAL WORKS


AMOUNT
S/N DESCRIPTION QTY UNIT RATE
A BILL NR. 5-EXTERNAL WORKS - CONT'D
B A54: Provisional work
C Allow provisional sums for the following items to be expended at the di
scretion of the Architect/Engineer
CONCRETE PLINTH

Allow a provisional sum for generator plinth size 4.2m x 3.0m. This cost PS
includes
excavation, concrete work, blocckwork and all associated electrical
works
SEPTIC TANK AND SOAK AWAY

Allow for a provisional sum for 2.8m x 3m septic tank and soakaway 1 No
pit, this cost includes excavation, concrete work, reinforcement and
associated blockwork.
Borehole and water treatment 1 No
Other External Works
carried to External Works summary
AMOUNT
S/N DESCRIPTION QTY UNIT RATE
EXTERNAL WORKS SUMMARY
PAVING
FENCING
OTHER EXTERNAL WORKS
CARRIED TO SUMMARY
GENERAL SUMMARY
AMOUNT
PROPOSED NSIB OFFICE COMPLEX BUILDING
MURTALA MUHAMMED INTERNATIONAL AIRPORT, IKEJA, LAGOS STATE
For:
NIGERIAN SAFETY INVESTIGATION BUREAU (NSIB)
A GENERAL SUMMARY -
B PRELIMINARIES -
C MAIN BUILDING (Building Works) -
D SECURITY AND GENERATOR HOUSE -
D ELECTRICAL INSTALLATIONS -
E ELV INSTALLATIONS -
F MECHANICAL - PLUMBING -
G MECHANICAL - HVAC -
H MECHANICAL - LIFT -
EXTERNAL WORKS
ADD: CONTINGENCY
ADD: VALUE ADDED TAX

-
-

-
-
PS
5.0%
7.5%
ESTIMATED CONSTRUCTION COST -